RIVERSIDE COUNTY FIRE DEPARTMENT
OFFICE OF THE FIRE MARSHAL CITY OF `
' CITY OF LAKE ELSINORE
130 S. Main St. Lake Elsinore,California 92530
LADE LSINO E
s (951)674-3124 Ext.250 Dbloo a) ake-Elsinore.Org DREAM EXTREME
PERMIT
PERMIT NO: 16-00001297 DATE: 6/07/16
JOB ADDRESS . . . . . 31910 MISSION TR
DESCRIPTION OF WORK FIRE SERVICES
OWNER CONTRACTOR
ARMSTRONG, RON DOO-RITE CONSTRUCTION
2430 OUR COUNTRY RD
ESCONDIDO CA 92029
LIC EXP 0/00/00
A. P. # . . . . . . 363-172-006 0 SQUARE FOOTAGE 0
OCCUPANCY . . . . GARAGE SQ FT 0
CONSTRUCTION . . . FIRE SPRNKLR
VALUATION . . . . ZONE . . . . . . UN
FIRE SERVICES
QTY UNIT CHG ITEM CHARGE
X 696 . 0000 LE FIRE TI >5, 000 SF
1 . 00 X 348 . 0000 LE FIRE TI <5, 000 SF 348 . 00
FEE SUMMARY CHARGES PAID DUE
PERMIT FEES
FIRE SERVICES 348 . 00 348 . 00 . 00
TOTAL 348 . 00 348 . 00 . 00
SPECIAL NOTES & CONDITIONS
ADA UPGRADE MOVE HALLWAY 6 ' , DEMO, NEW
WALLS, NEW HVAC, PLUMBING AND ELEC.
City of Lake Elsinore Please read and initial -A
LO i
Fire Services Division am Licensed under the provisions of Business and professional Code Section 7000 et seq.and
Post in conspicuous place my license is in full force.
on the job 2.I,as owner of the property.or my employees w/wages as their sole compensation will do the work
You must furnish PERMIT NUMBER and the and the structure is not intended or offered for sale.
JOB ADDRESS for each respective inspection: _1 I,as owner of the property,arn exclusively contracting with licensed contractors to construct the
Approved plans must be on job I project.
atall times: 4. 1 have a certificate of consent to selfinsure or a certificate of Workers Compensation Insurance
Inspection request(95 1)674-3 124 ext. 250 or a certified copy thereof.
.-5, 1 shall not employ any person in any manner so as to become subject to Workers Compensation
Laws in the performance of the work for which this permit is issued.
Note:If you should become subject to Workers Compensation after making this certification,
Code Approvals Date Inspector you must forthwith comply with such provisions or this permit shall be deemed revoked.
Sprinkler System Start Time Finish Time
SKO I UG Thrust Block PrePour
SK02 Underground Rough/Hydro
SK04 Underground Flush
SK05 Weld Inspection
SK06 Overhead Rough/Hydro
SK99 Overhead Final
SK08 High Pile Storage(FPE)
SK09 In-Rack Sprinklers
SKIO Hose Racks
SK03 Title 19 Verification
_SK07 Bell/Main D,ain/CMTC
Hydrant System Date 1Inspector
HSO I U.G.Thrust Block Pre-Pour
HS02 Underground Rough/Hydro
HS03 Underground Flush
HS99 1FinaI/Signs/CMTC
Knox System Date Inspector
KSO I Knox Rapid Entry
Fire Alarm Systems Date Inspectorl
FAO I Fire Alarm Wiring Insp.
FA02 Fire Alarm Function Test
FA03 Fire Alarm 24 1 Ir Battery
FA99 Fire Alarm Final
FA05 ISprinkler Monitoring
Fuel Storgae Tanks Date Inspector
FTO I Underground Tank(S)
FT02 Aboveground Tank(S)
FT03 Fuel Dispensers Only
I Building Inspections Date Inspector
FT99 1'171 Final
FS99 Shelf Final
Misc.Inspections Date Inspector
M101 Spray Booths
M102 Hood/Duct Suppression
M103 High Pile/Rack Storage
M104 H.P. Vents/Access/Corr.
M105 I laz-Mat Verification
M106 Other:
RIVERSIDE COUNTY FIRE DEPARTMENT
OFFICE OF THE FIRE MARSHAL
CITY OF LAKE ELSINORE L KE S M OKE-
130 S. Main St. a Lake Elsinore, California 92530
(951) 674-3124 Ext. 225 * Dblooxniy.Lake:K1§jq!1 e
PERMIT APPLICATION FORM
Permit No. 1/ -f ZZ�_ Project Name:
I understand that after the second submittal and after
Project Address: St oR ei failed inspections that additional fees will be required.
City & Zip: �ie Applicant Sign: Date:
Contact Information
CONTACT PERSON' 'JI P1 Lld- - Company Name: �A )61 e C f C
Plan Review Type (Check appropriate items)
KCommercial 0 Industrial 0 Residential 0 Special Event 0 Other
IQ Building 5k Building Tenant Improvement O Single Fam. Res. El Underground Wafer
0 Sprinkler System 0 TI Sprinkler System 0 Sprinkler Monitoring 0 Fire Alarm System
0 Hood & Duct Suppression System 0 Other Suppression System 0 Spray Booth 0 Cell Site
0 High Pile/Racks 0 Operating Permit 0 Other:
Storage Tank Submittals: 0 Dispensers Only 0 Above Ground 0 Underground
I st Submittal Offici al Use Only
ceived Date: Reviewed by: PC Review Date:
lans-1§'Approved Denied Letter Attached: 6 es ONo Job Card Included: Pyes ONo
Called for Pick-Up: Picked-Up Date: By:
,,r JQ Date Date Applicant Sign
2nd Submittal Official Use Only
Received Date: Reviewed by: PC Review Date:
'Plans: 0 Approved 0 Denied Letter Attached: OYes DNo Job Card Included: OYes IZINo
Called for Pick-Up: Picked-Up Date: By:
Date Date Applicant Sign
Resubmittal Fee Paid Date:
V Submittal Official Use Only
Received Date: Reviewed by: PC Review Date:
Plans: 0 Approved 0 Denied Letter Attached: OYes ONo Job Card Included: OYes ONo
Called for Pick-Up: Picked-Up Date: By:
Date Date Applicant Sign
Resubmittal Fee Paid Date:
. . . . . . . . . .
A■P%IGF LAKE ELSIN RE 1630.50
MONRE00009909 5/ /2016 9:I W)[
. TPA! e@I!!em¥5 its w-Reee»p+---
F$ E! CC TERM: 1 0.00
Tf : JJ
ARC ELECTRIC INC 16-1297 7 S.00
16-1297 348.00
100= 0-4 2 -348.00
Paid B%!:ARC ELECTRIC
CHEF 16: REF 6142
------------------------------------------
APPLIED 16M.50
TENDERED 1630.50
-------
CHANGE 0.00
RIVERSIDE COUNTY FIRE DEPARTMENT
OFFICE OF THE FIRE MARSHAL
CITY OF LAKE ELSINORE L A K� �� �
130 S. Main St. • Lake Elsinore, California 92530
(951) 674-3124 Ext. 225 • Dbloom(aLake-Elsinore.Org
Conditions of Approval
PERMIT #: 16-1297
Job: ARMSTRONG PRE-SCHOOL
Address: 31910 MISSION TRAIL, LAKE ELSIONRE
To: JIM ROSA
Phone:
E-MAIL:
Sq. Ft. 8,400 Occupancy Classification: E Total Occupant load: 175
Reviewed by. D. BLOOM Date: 5-31-2016
GENERAL CONDITIONS
1. LAKE ELSINORE FIRE PROTECTION PLANNING OFFICE RESPONSIBILITY- It is
the responsibility of the recipient of these Fire Department conditions to forward them to
all interested parties. The building permit number is required on all correspondence.
Questions should be directed to the Riverside County Office of the Fire Marshal Lake
Elsinore at 130 S Main St., Lake Elsinore, CA 92530. Phone: (951) 674-3124 Ext. 225,
Fax: (951) 471-1491.
2. APPROVED SYSTEMS- All of the following conditions titled "Prior to Final Inspection"
and/or any type of fire suppression systems must be reviewed, inspected and approved
by the Lake Elsinore Fire Protection Planning prior to Building Safety's final inspection.
The Fire Department letter of conditions, job card and approved plans must be at the job
site for all inspections.
3. ADOPTED CODES & LOCAL AMENDMENTS- The following plans have been
reviewed and conditioned with requirements that correspond with the appropriate
milestones. Regardless of the conditions, all plans shall comply with the Lake Elsinore
Municipal Code, the 2013 Adopted Codes (CFC, CBC, CMC, ect.), and all standards
referenced therein. These conditions are intended to assist in code compliance but, any
required provisions not named in these conditions shall also apply.
4. Separation of Occupancy- A fire barrier wall for the separation of occupancies is
required per the California Building Code. Fire walls, fire barriers, fire partitions, smoke
barriers, and smoke partitions or any other wall required to have protected openings or
penetrations shall be effectively and permanently identified with signs or stenciling. Such
identification shall be located in accessible concealed concealed floor, floor ceiling or
attic spaces repeated at intervals not exceeding 30 feet along the wall, and include
lettering not less than .5 inch in height, incorporating the suggested wording "FIRE
AND/OR SMOKE BARRIER—PROTECT ALL OPENINGS," or other wording.
Page 1 of 3
5. Address at Site-The site address shall be clearly posted at the job site entrance during
construction. This will enable incoming emergency equipment and inspectors to locate
the job site from the assigned street. Numbers shall be a minimum of 24 inches in
height.
6. Occupancy Limitations Based on Hazardous Materials- It is prohibited to
use/process or store any hazardous material in this occupancy that would exceed the
maximum allowable quantities in the California Building Code and/or California Fire
Code. Any change to the use, process, and quantities or to the type of hazardous
materials shall be approved by Lake Elsinore Fire Protection Planning Department.
Submittal of hazardous material classification and quantification report and plans will be
required. A change of the above or reclassification of an occupancy type to an "H"
occupancy will required a full plan submittal to the Building and Fire departments.
7. Operating Permit Required- This project has been review and may require an
operating permit in addition to the construction permit that has been conditioned for this
project in accordance with 105.6 of The California Fire Code.
PRIOR TO BUILDING FINAL INSPECTION
8. Adjust Existing Alarm System- The existing fire alarm system shall be modified to
provide proper coverage as required by the California Building Code, California Fire
Code and adopted standards. A C-10 licensed contractor must submit plans, along with
the current fee of $761.00, to the Fire Department for review and approval prior to
installation.
9. Hood/Duct Suppression System- A UL 300 hood/duct fire extinguishing system must
be installed over the cooking equipment as required by the California Fire Code,
California Mechanical Code and adopted standards. The extinguishing system must
automatically shut-down gas and /or electricity to all cooking appliances upon activation.
A C-16 licensed contractor must submit plans, along with the current $454.00 fee, to the
Fire Department for review and approval prior to installation. Alarm system supervision
is only required if the building has an existing fire alarm system.
10. Existing Fire Lanes- Existing fire lanes shall be maintained and additional fire lanes
may be required. Contact the Fire Department for guidance and any plan requirements.
The current deposit based plan check fee is $168.00
11, Automatic and Manual Gates- Gate(s) shall be automatic or manual operated. Install
Knox key operated switches with dust cover, installed mounted as recommended by the
Knox Company. Plans must be submitted to the Fire Department for approval of
mounting location/position and/or operating standards. Special forms are available from
this office for ordering the Key Switch. Current plan check fee is $212.00.
12. Extinguishers (Light Hazard)- Install a portable fire extinguisher, with a minimum rating
of 2A-10BC, for every 3,000 sq. ft. and/or 75 feet of travel distance. Fire extinguishers
shall be mounted no higher than 5 ft above finished floor, as measured to the top of the
extinguisher. Where not readily visible, signs shall be posted above all extinguishers to
indicate their locations. Extinguishers must have current CSFM service tags affixed; or
within one year of from the date of month and year of manufacture. (NOTE: If only a
year of manufacture is indicated, maintenance shall be due January 1st of the year
following.)
Page 2 of 3
13. Knox Rapid Entry Box- A rapid entry Knox Box shall be installed on the outside of the
building. If a Knox box has already been installed provide keys to the tenant space for
inclusion in the main building Knox Box. Key(s) shall have durable and legible tags
affixed for identification of the correlating tenant space. Special forms are available from
this office for ordering the Knox Box. If the building/facility is protected with a fire alarm
or burglar alarm system, it is recommended that the lock box be "tamper" monitoring.
14. Exiting and Illumination- All exiting, emergency lighting, and exit illumination shall be
installed and compliant pursuant to all provisions of chapter 10, CFC 2013 edition.
15. Egress Door Hardware- All egress door hardware shall comply with the California
Building Code.
16. Flame Retardant Decorative Materials and Certificate- Submit to the Fire Department
flame-retardant certification(s) by applicator or manufacturer, along with CSFM Listing,
for all decorative materials used in this facility. Samples of flame-retardant material(s)
may be required for flame spread testing. All required treated materials must have a
current CSFM approval tag affixed to each item or panel.
17. Display Address (Building)- Display street numbers in a prominent location on the
address side of building(s) and rear access if applicable. Numbers and letters shall be a
minimum of 12" in height for building(s) up to 25' in height and 24" in height for
building(s) exceeding 25' in height. All addressing must be legible, of a contrasting color
with the background and adequately illuminated to be visible from the street at all hours.
All lettering shall be to Architectural Standards.
18. Electrical Room Sign- Electrical room door shall be posted "ELECTRICAL ROOM" on
the outside of the door.
19. Occupant Load Sign- Room occupancy load, as approved by the Building Official, shall
be posted in a conspicuous place near the main exit from the room(s). The location
shall be approved by the Fire Department. Posting shall be by means of an approved
durable sign having a contrasting color from the background to which it is attached. The
owner shall maintain signs in a legible manner. No person shall deface, remove or
change the occupant load on the sign except as authorized by the Building Official
and/or Fire Department.
20. Final Inspection- Prior to final fire approval you must be cleared by the Fire
h building prior to final
e conducted in the bu d
Department. Business is not allowed to b g p
approval. Call our office to request a Fire Department inspection when you have
approved plans and have installed items as required.
Lake Elsinore Office of the Fire Marshal (951) 674-3124 Ext, 225
Doug Bloom
Assistant Fire Marshal
If any of the conditions are unclear, difficult to understand, or you would like to
set-up a meeting please feel free to contact me at (951) 674-3124 Ext. 225 so that I
can better assist you in the approval of this project.
Page 3 of 3
L,a,.l ZE17 g -- 1 --
iL gay SL SL � �
Dom ., _ ooaR ooaa
N
Do
4 � t
NNW
am Raa11 2 FF a CUBS Raw ROOM♦ c9m ROOM a CLAM JO W 8 w`j CU55 Bann 7
a73'SO. , GAS SO.FT. 30 Ff, M 10.IS. M7 FA F7. "y �. 1713 sm FT.
1%20.mis ,A }ja __ 1/20 37A 3" UA FF.1/SO-ri:53
r'/0 P 7,sa 10a t s7uoFxrj OW
1 vS&I amc zll scR
NL
V� O0
*UK mr
ROOK 7p47t 7MOf OOOSt WAIX OW IN"tWY V-1
I \
70 OW L7 GOOK DOOR D L7 SL Dom �