HomeMy WebLinkAboutFairfield at Alberhill Ranch Post-tension Placement Calcs (Delta 3 Dated 09-06-23)_v1.pdf-APPROVED REVISIONSVery Low (E.I. = 0-20)
Low (E.I. = 21-50)
Medium (E.I. = 51-90)
1500 psf
Soils Report Job #:
Soils Report Date:
JULY 31, 2023 (REV. AUGUST 14, 2023)
Suncoast Post-Tension Job #
Post Tension Foundation Design Summary
Post Tension Foundation Calculations for:
PULTE HOMES
FAIRFIELD AT ALBERHILL RANCH
LAKE ELSINORE, CA
Category I
22-8351
NOVEMBER 14, 2022 / MAY 12, 2023 /
Allowable Bearing Capacity of:
Soils Report By:PETRA GEOSCIENCES
J.N. 21-467
20" 15" 4.5"
Category II 23" 15" 4.5"
Slab
Thickness
20" 12" 4.5"
Category IA
Category Ext. Beam Int. Beam
IAN R . WAD
D
E
LLC
I V ILNo. CO41219
03-31-25
ST
AT
E OF C A L IF O R NIAREGISTERED P R O F E S S ION
A
L
ENGINEER
CATEGORY IA CALCS FOR ALL PLAN TYPES
4 -1/2” POST-TENSIONED SLAB ON GRADE
CALCULATIONS
By: Suncoast Post-Tension Utilizing the California Foundation Slab Method (Spanability
Method) for Very Low Expansive Soils in accordance with the provisions of the Post-
Tensioning Institute “Design and Construction of Post-Tensioned Slabs-On-Ground”
PROJECT: PULTE HOMES – FAIRFIELD AT ALBERHILL RANCH
in LAKE ELSINORE, CA
GENERAL DESIGN CRITERIA:
1. Allowable soil bearing pressures of 1500 psf.
2. Soils are Very low expansive.
3.Generally in accordance with the California Foundation Slab Method (Spanability
Method) and the California Building Code.
4. The slab thickness is t = 4.5 inches minimum.
5. These calculations and associated drawings for this project have been designed in a
manner consistent with that level of care and skill ordinarily exercised by members of the
profession currently practicing in the same locality under similar conditions.
MATERIALS DESIGN CRITERIA:
A) Concrete Materials:
fci = 2000 psi @ time of stressing
fc = 2500 psi @ 28 days
Ec = 2,850,000 psi
fc = .45 fc = .45 (2500) psi = 1125 psi
ft = 6x (fc^.5) = 6x (2500^ .5) = 300 psi
vc = 1.7x fc^.5 + .1x fp = 95 psi
B) Post-Tensioning Materials:
½” Dia. 270 ksi & elongation = PL/AE = .081 L (where L is in feet)
Pjack = 31 kips, Panchor = 29 kips, Peffective = 26.6 kips (min)
Provide for a minimum of 50 psi compression in both directions.
Page 1 of 6
SOIL DESIGN CRITERIA:
A) General assumptions used are as established in the current report on conditions, data
and recommendations by the soil engineer of record.
Soils Report: Petra Geosciences Report#: J.N. 21-467
Dated: November 14, 2022 / May 12, 2023 / July 31, 2023 (Rev. August 14, 2023)
B) Typical slab panel see plan.
C) Soil Type; See report
D) Attenburg Limits: N/A
E) Differential Swell Estimate: N/A
TYPICAL WORST CASE LOADING:
Dead Load Live Load
Roof Level 25 psf 20 psf
2nd Floor Level 35 psf 40 psf(24 reduced)
Ground Floor 15 psf 40 psf
75 psf 100 psf
Superimposed Wall Loads
Total DL + LL (Red.) = 159 psf for two story 159.00 256.00
Total DL + LL = 100 psf for one story 100.00 128.00
MAXIMUM EXTERIOR GRADE BEAM LOADING: (superimposed)
Pp/ft = DL wall + tributary Pp 1550.00 plf (maximum average)
MAXIMUM INTERIOR BEARING WALL LOADING: (superimposed)
Pi/ft = DL wall + tributary Pi 1800.00 plf (maximum average)
DESIGN ANALYSIS SECTIONS:
A) Interior Bearing Walls (Primary).
B) Interior Non-Bearing Walls (Secondary).
C) Exterior Load Bearing Walls.
D) Exterior Post Support.
E) Slab Support Analysis.
F) Post Load on Slab Analysis.
Page 2 of 6
DESIGN ANALYSIS:
A) Interior Bearing Walls:
Set interior grade beam at 12” wide x 12” deep
1. Loading:
W superimposed 1800.00 plf
W total (1800 + 400) 2200.00 plf
2. Design Section: 12” Wide x 12” Deep T Section
Area = 387 in^2, Av = 144 in^2, Yb = 8.35”, Icg = 3409 in^4, Sb = 408.33 in^3
3. Unsupported Length: (L)
M actual = (W X L^2)/12 fixed – fixed analysis
= 2200 x L^2/12 = 183.3 L^2
f section = P/A + ft (allowable)
= (26.6 x 1,000)/387 + 300psi
= 369 psi
Since ft = (M x c)/Icg, then (183.3L^2 x c)/Icg
Solving for L
(183.3 x 12 x L^2 x 8.35)/3409 = 369
L = 8.3 feet OKAY
4. Deflection: (Do)
Do = (W X L^4)/384 x E x Icg for fixed – fixed analysis
Do = .005 inches less than L/360 = .28 inches. OKAY
5. Soil Bearing: (Qo) = 2200lbs./5.0sf = 440 psf < Qallowable OKAY
B) Interior Non-Bearing Walls:
Set section at 60” wide by slab thickness of 4.5”
1. Loading:
W superimposed 795.00 plf
W total (795 + 280) 1075 plf
2. Design Section: 60” Wide X 4.0” Deep Rectangular Section
Area = 270 in^2, Av = 270 in^2, Yb = 2.25”, Icg = 501 in^4, Sb = 222 in^3
3. Unsupported Length: (L)
M actual = (W X L^2)/12 fixed – fixed analysis
= 1,075 x L^2/12 = 89.6 L^2
f section = P/A + ft (allowable)
= (26.6 x 1,000)/270 + 300psi
= 398.5 psi
Since ft = (M x c)/Icg, then (89.6 L^2 x c)/Icg = 398.5 psi
Solving for L
(89.6 x 12 x L^2 x 2.25)/501 = 410.8 L = 9.2 feet OKAY
4. Deflection: (Do)
Do = (W X L^4)/384 x E x Icg for fixed – fixed analysis
Do = .024 inches less than L/360 = .26 inches. OKAY
5. Soil Bearing: (Qo) = 1075lbs./5sf = 215psf < Q allowable OKAY
Page 3 of 6
C) Exterior Load Bearing Walls:
Set exterior grade beam at 12” wide x 18” deep
1. Loading:
W superimposed 1550.00 plf
W total (1550 + 350) 1900.00 plf
2. Design Section: 12” Wide X 18” Deep Half T Section
Area = 338 in^2, Av = 216 in^2, Yb = 11.43”, Icg = 9580 in^4, Sb = 838 in^3
3. Unsupported Length: (L)
M actual = (W X L^2)/12 fixed – fixed analysis
= 1900 x L^2/12 = 158.3 L^2
f section = P/A + ft (allowable)
= 50 + 300 psi
= 350 psi
Since ft = (M x c)/Icg, then (158.3L^2 x c)/Icg = 350 psi
Solving for L
(158.3 x 12 x L^2 x 11.43)/9580 = 350
L = 12.4 feet OKAY
4. Deflection: (Do)
Do = (W X L^4)/384 x E x Icg for fixed – fixed analysis
Do = .007 inches less than L/360 = .42 inches. OKAY
5. Soil Bearing: (Qo) = 1900lbs./2.5sf = 760 psf < Q allowable OKAY
D) Exterior Post Support:
Set exterior grade beam at 12” wide x 18” deep
1. Loading:
P superimposed 10000.00 pounds
P total 11750.00 pounds
2. Design Section: 12” Wide X 18” Deep Half T Section
Area = 338 in^2, Av = 216 in^2, Yb = 11.43”, Icg = 9580 in^4, Sb = 838 in^3
3. Unsupported Length: (L) Assume 10 feet
M actual = (P X L)/8 fixed – fixed analysis
= 1468.75 L ft-lbs.
f section = P/A + ft (allowable)
= 50 + 300psi
= 350 psi
ft actual =M/S =350 psi < 350 psi allowable OKAY
L = 16.60 feet OKAY
4. Deflection: (Do)
Do = (P X L^3)/192 x E x Icg for fixed – fixed analysis
Do = .018 inches less than L/360 = .57 inches. OKAY
5. Soil Bearing: (Qo) = 11750lbs./2.5 x 17.0sf = 276 psf < Q allowable OKAY
Page 4 of 6
E) Slab Support Analysis:
Set section at 60” wide by slab thickness of 4.5”
1. Loading:
LL superimposed 40.00 psf
DL + LL total (56 + 40) 96.00 psf
2. Design Section: 60” Wide X 4.5” Deep Rectangular Sectic
Area = 270 in^2, Av = 270 in^2, Yb = 2.25”, Icg = 455 in^4, Sb = 202 in^3
3. Unsupported Length: (L)
M actual = (W X L^2)/12 fixed – fixed analysis
= 96 x 5 x L^2/12 = 40 L^2
f section = P/A + ft (allowable)
= (26.6 x 1,000)/270 + 300psi
= 398.5 psi
Since ft = (M x c)/Icg, then (40L^2 x c)/Icg
Solving for L
(40 x 12 x L^2 x 2.25)/455 = 398.5 L = 12.9 feet OKAY
4. Deflection: (Do)
Do = (W X L^4)/384 x E x Icg for fixed – fixed analysis
Do = .05 inches less than L/360 = .40 inches. OKAY
5. Soil Bearing: (Qo) = 480lbs./5sf = 96psf < Q allowable OKAY
F) Post Load on Slab Analysis:
Assume a 3.5” x 3.5” post on a 4.5” thick slab no grade beams.
1. Loading:
P superimposed 4500.00 pounds
P total (4500 + 500) 5000.00 pounds
2. Design Section: 60” Wide X 4.5” Deep Rectangular Section
Area =270 in^2, Av = 270 in^2, Yb = 2.25”, Icg = 455 in^4, Sb = 202 in^3
3. Unsupported Length: (L) Assume 10 feet
M actual = (P X L)/8 fixed – fixed analysis
= 625 L ft-lbs.
f section = P/A + ft (allowable)
= (26.6 x 1,000)/270 + 300psi
= 398.5 psi
Solving for L
(625 x 12 x L)/202 = 398.5 L = 10.70 feet OKAY
4. Shear Capacity: 4,500 pounds superimposed
5. Deflection: (Do)
Do = (P X L^3)/192 x E x Icg for fixed – fixed analysis
Do = .04 inches less than L/360 = .29 inches. OKAY
6. Soil Bearing: (Qo) = 5000lbs./53.5sf = 93.5psf < Q allowable OKAY
Page 5 of 6
DESIGN SUMMARY:
Use a 4.5” slab, 12” wide by 18” deep beams at exterior edges and 12” wide by 12”
deep interior grade beams as shown on the plans with ½” dia. 270 ksi 7 wire strands
spaced at 5’-6” o.c. +/- 6” each way mid height in the slab.
ANCHOR ANALYSIS NO BACK UP BARS:
NOTES:
1) Anchor size is 2.25” x 5” placed 3.5” from center of anchor to top of slab.
2) Allowable stresses by ACI-318.
3) Concrete at time of stressing is 2000psi.
4) Concrete at 28 days is 2500psi.
ANALYSIS:
Allowable stress at transfer fcp= .8xfci x ((Ab’/Ab-.2)^.5)<or= 1.25 x fci
Allowable stress at service fcp= .6xfc x((Ab’/Ab)^.5) < or = 1.0 x fc
Ab’= 5” x 7.75” = 38.75 in^2
Ab = 2.25 x 5 –(.75/2)^2 x PIE = 10.81 in^2
fc = 2500 psi and fci = 2000 psi
At transfer fcp = .8 x 2000(38.75/10.81)^.5 = 2943 psi > 2500 psi(governs)
Actual at transfer =fact =Force/Ab =.7x270x.153/10.81 = 2675 = approx. 2500psi
At service fcp = .6x2500(38.75/10.81)^.5 = 2839 > 2500 psi (governs)
Actual at service = fact = .6x270x.153/10.81 = 2293 <2500 psi OK
Therefore back up bars are not required with a 2.25” x 5” anchor.
LIMITATIONS:
Suncoast Post-Tension & the Engineer whose stamp appears on these calculations and
plans assumes no responsibility for future defects resulting from unreported conditions
mitigating the general design, material design and/or soil design criteria’s or when
accompanied by an apparent creep of the slab foundation and soils. Although there is no
known method of totally preventing movements due to expansive soils, current state-of-
the-practice in Southern California area dictates post tensioned slab on grades as the
method of minimizing the effects of expansive soils.
QUALITY CONTROLS:
The subcontractors performing the work are responsible for quality in include; exact
concrete dimensions, integrally poured monolithic concrete, no rock pockets, debris or
soil intrusions and accurate post tensioning strand support and placement.
Page 6 of 6
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4521) Cat I
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
RIBBED FOUNDATION - DESIGN SUMMARY
Slab Dimensions : 45.00 FT x 67.20 FT x 4.50 Inches
Material Properties
Concrete Strength, f'c :3,000 PSI
Tendon Strength, Fpu :270 KSI
Tendon Diameter :1 / 2 Inch
Material Quantities
Concrete Volume :64.4 Cubic Yards
Prestressing Tendon :1,746 Linear Feet
Number of End Anchorages :62
In the LONG direction ... Type I Beam Type II Beam
Quantity of Beams : 2 2
Depth of Beams : 18.0 Inches 15.0 Inches
Width of Beams : 12.0 Inches 12.0 Inches
Tendons per Beam : 1 1
Beam Tendon Centroid : 3.25 Inches 3.25 Inches
Beam Spacing :15.00 Feet O.C.
Number of Slab Tendons :9
Slab Tendon Spacing :5.13 Feet O.C.
Slab Tendon Centroid :2.25 Inches from top of slab
In the SHORT direction ... Type I Beam Type II Beam
Quantity of Beams : 4 4
Depth of Beams : 18.0 Inches 15.0 Inches
Width of Beams : 12.0 Inches 12.0 Inches
Tendons per Beam : 1 1
Beam Tendon Centroid : 3.25 Inches 3.25 Inches
Beam Spacing :9.60 Feet O.C.
Number of Slab Tendons :10
Slab Tendon Spacing :7.02 Feet O.C.
Slab Tendon Centroid :2.25 Inches from top of slab
Page 1 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\1. Plan 4521-Cat I.pti 11:34:27 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4521) Cat I
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
RIBBED FOUNDATION - DESIGN COMPLIANCE SUMMARY
The BOLD values exceed allowable or are less than minimum limits by the percentage indicated:
SOIL BEARING :
SOIL BEARING: 0.0%
CENTER LIFT MODE :
ALL VALUES WITHIN ALLOWABLE LIMITS.
EDGE LIFT MODE :
ALL VALUES WITHIN ALLOWABLE LIMITS.
Page 2 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\1. Plan 4521-Cat I.pti 11:34:27 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4521) Cat I
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
RIBBED FOUNDATION - RESULTS OF ANALYSIS
Soil Bearing Analysis
Total Applied Load 373,215 LB
Bearing Area 2,566 FT2
Applied Pressure on Soil 145 PSF
Soil Pressure Safety Factor 0.00
Prestress Summary
Subgrade Friction calculated by method prescribed in PTI Manual
Short Long
Direction Direction
Number of Slab Tendons 10 9
Number of Beam Tendons 8 4
Spacing of Slab Tendons (Feet)7.02 5.13
Center of Gravity of Concrete (from top of slab) (Inch) 4.28 3.87
Center of Gravity of Tendons (from top of slab) (Inch) 7.22 5.69
Eccentricity of Prestressing (Inch)-2.94 -1.82
Minimum Effective Prestress Force (K) 384.6 251.5
Beta Distance Effective Prestress Force (K) 442.3 324.9
Minimum Effective Prestress (PSI)80 83
Beta Distance Effective Prestress (PSI) 92 108
Moment Analysis - Center Lift Mode
Maximum Moment, Short Dir. (controlled by Em=5.0 per PTI 4.3.2) 5.80 FT-K/FT
Maximum Moment, Long Dir. (controlled by Em=5.0 per PTI 4.3.2) 5.52 FT-K/FT
Tension in Top Fiber (KSI) Compression in Bottom Fiber (KSI)
Short Long Short Long
Direction Direction Direction Direction
Allowable Stress -0.329 -0.329 Allowable Stress 1.350 1.350
Actual Stress -0.220 -0.206 Actual Stress 0.995 1.147
Stiffness Analysis - Center Lift Mode
Based on a Stiffness Coefficient of 360 Short Long
Direction Direction
Available Moment of Inertia (Inch4) 82,108 44,072
Required Moment of Inertia (Inch4) 50,511 32,275
Required Moment of Inertia controlled by Width 6*Beta
Shear Analysis - Center Lift Mode
Maximum Shear, Short Direction.1.41 K/FT
Maximum Shear, Long Direction 1.36 K/FT
Short Long
Direction Direction
Allowable Shear Stress (PSI)150 153
Actual Shear Stress (PSI)59 77
Page 3 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\1. Plan 4521-Cat I.pti 11:34:27 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4521) Cat I
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
RIBBED FOUNDATION - RESULTS OF ANALYSIS continued
Cracked Section Analysis - Center Lift Mode
Short Long
Direction Direction
Cracked Section Capacity (FT-K)308.1 268.5
0.5 Moment (FT-K)194.9 124.3
Moment Analysis - Edge Lift Mode
Maximum Moment, Short Direction 3.34 FT-K/FT
Maximum Moment, Long Direction 3.04 FT-K/FT
Tension in Bottom Fiber (KSI) Compression in Top Fiber (KSI)
Short Long Short Long
Direction Direction Direction Direction
Allowable Stress -0.329 -0.329 Allowable Stress 1.350 1.350
Actual Stress -0.118 -0.197 Actual Stress 0.165 0.20
Stiffness Analysis - Edge Lift Mode
Based on a Stiffness Coefficient of 720 Short Long
Direction Direction
Available Moment of Inertia (Inch4) 82,108 44,072
Required Moment of Inertia (Inch4) 58,125 35,485
Required Moment of Inertia controlled by Width 6*Beta
Shear Analysis - Edge Lift Mode
Maximum Shear, Short Direction 1.53 K/FT
Maximum Shear, Long Direction 1.56 K/FT
Short Long
Direction Direction
Allowable Shear Stress (PSI)150 153
Actual Shear Stress (PSI)64 88
Cracked Section Analysis - Edge Lift Mode
Short Long
Direction Direction
Cracked Section Capacity (FT-K)237.5 118.8
0.5 Moment (FT-K)112.1 68.3
Page 4 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\1. Plan 4521-Cat I.pti 11:34:27 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4521) Cat I
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
RIBBED FOUNDATION - SELECTED VARIABLES
Short Long
Direction Direction
Cross Sectional Area (Inch2) :4,798 3,014
Moment of Inertia (Inch4) :82,108 44,072
Section Modulus, Top (Inch3) :19,172 11,398
Section Modulus, Bottom (Inch3) : 6,622 3,441
Center of Gravity of Concrete - from top (Inch) : 4.28 3.87
Center of Gravity of Prestressing Tendons - from top (Inch) : 7.22 5.69
Eccentricity of Prestress (Inch) :-2.94 -1.82
Beta Distance (Feet) :8.78 7.51
Equivalent Beam Depth (Inches) : 16.68 16.68
Note: All Calculations above and other reported values which
depend on depths use the equivalent depths as shown above.
Jacking Force :33.05 KIPS
Page 5 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\1. Plan 4521-Cat I.pti 11:34:27 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4521) Cat I
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
SUMMARY OF INPUT DATA
Material Properties
Concrete Strength, f'c :3,000.0 PSI
Concrete Creep Modulus, Ec : 1,500,000.0 PSI
Concrete Unit Weight :145.0 PCF
Tendon Strength, Fpu :270.0 KSI
Tendon Diameter :1 / 2 Inch
Slab Properties
Rectangle Geometry : 45.00 FT x 67.20 FT x 4.50 Inches
Short Direction Long Direction
Minimum Permissible Prestress : 80.00 PSI 80.00 PSI
Beam Properties
Short Direction Long Direction
Type I Type II Type I Type II
Quantity : 4 4 2 2
Depth : 18.0 15.0 18.0 15.0 Inches
Width : 12.0 12.0 12.0 12.0 Inches
Tendons : 1 1 1 1
Cover : 3.00 3.00 3.00 3.00 Inches
Average beam spacing used in analysis
Page 6 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\1. Plan 4521-Cat I.pti 11:34:27 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4521) Cat I
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
SUMMARY OF INPUT DATA - Continued
Soil Properties
Allowable Bearing Pressure : 1,500.0 PSF
Center Lift Edge Lift
Edge Moisture Variation Distance, em : 9.00 Feet 4.70 Feet
Differential Soil Movement, ym : 0.350 Inches 0.650 Inches
Load, Deflection and Subgrade Properties
Slab Loading
Uniform Superimposed Total Load : 40.00 PSF
Total Perimeter Load : 1,000.00 PLF
Stiffness Coefficients
Center Lift :360
Edge Lift :720
Prestress Calculation
Subgrade Friction calculated by method prescribed in PTI Manual
Prestress Loss :15.0 KSI
Subgrade Friction Coefficient : 0.75
Page 7 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\1. Plan 4521-Cat I.pti 11:34:27 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4521) Cat I
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
PTI EXCEPTION SUMMARY
The following elements of the design are not in strict compliance with the
Design of Post-Tensioned Slabs-On-Ground 3rd Edition manual
published by the Post-Tensioning Institute.
NO PTI EXCEPTIONS EXIST
Page 8 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\1. Plan 4521-Cat I.pti 11:34:27 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4521) Cat I
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
LINE LOAD ANALYSIS
Summary of Input Data
Line Load :1,800.0 lb/ft
Direction Of Line Load : Parallel to Long Direction
Prestress at Line Load : Minimum Effective Prestress
Soil Modulus, Ks :40 PCI
Slab Thickness : 4.50 Inch
Concrete Creep Modulus, Ec :1,500,000.0 PSI
Summary of Line Load Analysis
Applied Moment :1.23 Ft-K/Ft
Bending Stresses (KSI)
Tension in Extreme Fiber Compression in Extreme Fiber
Allowable Stress : -0.329 1.350
Applied Stress : -0.283 0.443
Prestress at Line Load :80.2 PSI
Design Compliance Summary
The BOLD values exceed allowable or are less than minimum limits by the percentage indicated:
ALL VALUES WITHIN ALLOWABLE LIMITS.
Page 9 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\1. Plan 4521-Cat I.pti 11:34:27 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4521) Cat II
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
RIBBED FOUNDATION - DESIGN SUMMARY
Slab Dimensions : 45.00 FT x 67.20 FT x 4.50 Inches
Material Properties
Concrete Strength, f'c :3,000 PSI
Tendon Strength, Fpu :270 KSI
Tendon Diameter :1 / 2 Inch
Material Quantities
Concrete Volume :64.4 Cubic Yards
Prestressing Tendon :1,746 Linear Feet
Number of End Anchorages :62
In the LONG direction ... Type I Beam Type II Beam
Quantity of Beams : 2 2
Depth of Beams : 18.0 Inches 15.0 Inches
Width of Beams : 12.0 Inches 12.0 Inches
Tendons per Beam : 1 1
Beam Tendon Centroid : 3.25 Inches 3.25 Inches
Beam Spacing :15.00 Feet O.C.
Number of Slab Tendons :9
Slab Tendon Spacing :5.13 Feet O.C.
Slab Tendon Centroid :2.25 Inches from top of slab
In the SHORT direction ... Type I Beam Type II Beam
Quantity of Beams : 4 4
Depth of Beams : 18.0 Inches 15.0 Inches
Width of Beams : 12.0 Inches 12.0 Inches
Tendons per Beam : 1 1
Beam Tendon Centroid : 3.25 Inches 3.25 Inches
Beam Spacing :9.60 Feet O.C.
Number of Slab Tendons :10
Slab Tendon Spacing :7.02 Feet O.C.
Slab Tendon Centroid :2.25 Inches from top of slab
Page 1 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\1. Plan 4521-Cat II.pti 11:34:48 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4521) Cat II
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
RIBBED FOUNDATION - DESIGN COMPLIANCE SUMMARY
The BOLD values exceed allowable or are less than minimum limits by the percentage indicated:
SOIL BEARING :
SOIL BEARING: 0.0%
CENTER LIFT MODE :
ALL VALUES WITHIN ALLOWABLE LIMITS.
EDGE LIFT MODE :
ALL VALUES WITHIN ALLOWABLE LIMITS.
Page 2 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\1. Plan 4521-Cat II.pti 11:34:48 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4521) Cat II
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
RIBBED FOUNDATION - RESULTS OF ANALYSIS
Soil Bearing Analysis
Total Applied Load 373,215 LB
Bearing Area 2,566 FT2
Applied Pressure on Soil 145 PSF
Soil Pressure Safety Factor 0.00
Prestress Summary
Subgrade Friction calculated by method prescribed in PTI Manual
Short Long
Direction Direction
Number of Slab Tendons 10 9
Number of Beam Tendons 8 4
Spacing of Slab Tendons (Feet)7.02 5.13
Center of Gravity of Concrete (from top of slab) (Inch) 4.28 3.87
Center of Gravity of Tendons (from top of slab) (Inch) 7.22 5.69
Eccentricity of Prestressing (Inch)-2.94 -1.82
Minimum Effective Prestress Force (K) 384.6 251.5
Beta Distance Effective Prestress Force (K) 442.3 324.9
Minimum Effective Prestress (PSI)80 83
Beta Distance Effective Prestress (PSI) 92 108
Moment Analysis - Center Lift Mode
Maximum Moment, Short Dir. (controlled by Em=5.0 per PTI 4.3.2) 6.09 FT-K/FT
Maximum Moment, Long Dir. (controlled by Em=5.0 per PTI 4.3.2) 5.80 FT-K/FT
Tension in Top Fiber (KSI) Compression in Bottom Fiber (KSI)
Short Long Short Long
Direction Direction Direction Direction
Allowable Stress -0.329 -0.329 Allowable Stress 1.350 1.350
Actual Stress -0.232 -0.219 Actual Stress 1.030 1.190
Stiffness Analysis - Center Lift Mode
Based on a Stiffness Coefficient of 360 Short Long
Direction Direction
Available Moment of Inertia (Inch4) 82,108 44,072
Required Moment of Inertia (Inch4) 53,022 33,879
Required Moment of Inertia controlled by Width 6*Beta
Shear Analysis - Center Lift Mode
Maximum Shear, Short Direction.1.43 K/FT
Maximum Shear, Long Direction 1.42 K/FT
Short Long
Direction Direction
Allowable Shear Stress (PSI)150 153
Actual Shear Stress (PSI)60 80
Page 3 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\1. Plan 4521-Cat II.pti 11:34:48 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4521) Cat II
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
RIBBED FOUNDATION - RESULTS OF ANALYSIS continued
Cracked Section Analysis - Center Lift Mode
Short Long
Direction Direction
Cracked Section Capacity (FT-K)308.1 268.5
0.5 Moment (FT-K)204.6 130.5
Moment Analysis - Edge Lift Mode
Maximum Moment, Short Direction 3.57 FT-K/FT
Maximum Moment, Long Direction 3.32 FT-K/FT
Tension in Bottom Fiber (KSI) Compression in Top Fiber (KSI)
Short Long Short Long
Direction Direction Direction Direction
Allowable Stress -0.329 -0.329 Allowable Stress 1.350 1.350
Actual Stress -0.147 -0.241 Actual Stress 0.175 0.213
Stiffness Analysis - Edge Lift Mode
Based on a Stiffness Coefficient of 720 Short Long
Direction Direction
Available Moment of Inertia (Inch4) 82,108 44,072
Required Moment of Inertia (Inch4) 62,215 38,801
Required Moment of Inertia controlled by Width 6*Beta
Shear Analysis - Edge Lift Mode
Maximum Shear, Short Direction 1.80 K/FT
Maximum Shear, Long Direction 1.84 K/FT
Short Long
Direction Direction
Allowable Shear Stress (PSI)150 153
Actual Shear Stress (PSI)76 103
Cracked Section Analysis - Edge Lift Mode
Short Long
Direction Direction
Cracked Section Capacity (FT-K)237.5 118.8
0.5 Moment (FT-K)120.0 74.7
Page 4 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\1. Plan 4521-Cat II.pti 11:34:48 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4521) Cat II
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
RIBBED FOUNDATION - SELECTED VARIABLES
Short Long
Direction Direction
Cross Sectional Area (Inch2) :4,798 3,014
Moment of Inertia (Inch4) :82,108 44,072
Section Modulus, Top (Inch3) :19,172 11,398
Section Modulus, Bottom (Inch3) : 6,622 3,441
Center of Gravity of Concrete - from top (Inch) : 4.28 3.87
Center of Gravity of Prestressing Tendons - from top (Inch) : 7.22 5.69
Eccentricity of Prestress (Inch) :-2.94 -1.82
Beta Distance (Feet) :8.78 7.51
Equivalent Beam Depth (Inches) : 16.68 16.68
Note: All Calculations above and other reported values which
depend on depths use the equivalent depths as shown above.
Jacking Force :33.05 KIPS
Page 5 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\1. Plan 4521-Cat II.pti 11:34:48 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4521) Cat II
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
SUMMARY OF INPUT DATA
Material Properties
Concrete Strength, f'c :3,000.0 PSI
Concrete Creep Modulus, Ec : 1,500,000.0 PSI
Concrete Unit Weight :145.0 PCF
Tendon Strength, Fpu :270.0 KSI
Tendon Diameter :1 / 2 Inch
Slab Properties
Rectangle Geometry : 45.00 FT x 67.20 FT x 4.50 Inches
Short Direction Long Direction
Minimum Permissible Prestress : 80.00 PSI 80.00 PSI
Beam Properties
Short Direction Long Direction
Type I Type II Type I Type II
Quantity : 4 4 2 2
Depth : 18.0 15.0 18.0 15.0 Inches
Width : 12.0 12.0 12.0 12.0 Inches
Tendons : 1 1 1 1
Cover : 3.00 3.00 3.00 3.00 Inches
Average beam spacing used in analysis
Page 6 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\1. Plan 4521-Cat II.pti 11:34:48 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4521) Cat II
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
SUMMARY OF INPUT DATA - Continued
Soil Properties
Allowable Bearing Pressure : 1,500.0 PSF
Center Lift Edge Lift
Edge Moisture Variation Distance, em : 8.50 Feet 4.20 Feet
Differential Soil Movement, ym : 0.450 Inches 0.850 Inches
Load, Deflection and Subgrade Properties
Slab Loading
Uniform Superimposed Total Load : 40.00 PSF
Total Perimeter Load : 1,000.00 PLF
Stiffness Coefficients
Center Lift :360
Edge Lift :720
Prestress Calculation
Subgrade Friction calculated by method prescribed in PTI Manual
Prestress Loss :15.0 KSI
Subgrade Friction Coefficient : 0.75
Page 7 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\1. Plan 4521-Cat II.pti 11:34:48 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4521) Cat II
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
PTI EXCEPTION SUMMARY
The following elements of the design are not in strict compliance with the
Design of Post-Tensioned Slabs-On-Ground 3rd Edition manual
published by the Post-Tensioning Institute.
NO PTI EXCEPTIONS EXIST
Page 8 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\1. Plan 4521-Cat II.pti 11:34:48 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4521) Cat II
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
LINE LOAD ANALYSIS
Summary of Input Data
Line Load :1,800.0 lb/ft
Direction Of Line Load : Parallel to Long Direction
Prestress at Line Load : Minimum Effective Prestress
Soil Modulus, Ks :40 PCI
Slab Thickness : 4.50 Inch
Concrete Creep Modulus, Ec :1,500,000.0 PSI
Summary of Line Load Analysis
Applied Moment :1.23 Ft-K/Ft
Bending Stresses (KSI)
Tension in Extreme Fiber Compression in Extreme Fiber
Allowable Stress : -0.329 1.350
Applied Stress : -0.283 0.443
Prestress at Line Load :80.2 PSI
Design Compliance Summary
The BOLD values exceed allowable or are less than minimum limits by the percentage indicated:
ALL VALUES WITHIN ALLOWABLE LIMITS.
Page 9 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\1. Plan 4521-Cat II.pti 11:34:48 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4026) Cat I
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
RIBBED FOUNDATION - DESIGN SUMMARY
Slab Dimensions : 40.00 FT x 51.00 FT x 4.50 Inches
Material Properties
Concrete Strength, f'c :3,000 PSI
Tendon Strength, Fpu :270 KSI
Tendon Diameter :1 / 2 Inch
Material Quantities
Concrete Volume :42.6 Cubic Yards
Prestressing Tendon :1,129 Linear Feet
Number of End Anchorages :48
In the LONG direction ... Type I Beam Type II Beam
Quantity of Beams : 2 2
Depth of Beams : 18.0 Inches 15.0 Inches
Width of Beams : 12.0 Inches 12.0 Inches
Tendons per Beam : 1 1
Beam Tendon Centroid : 3.25 Inches 3.25 Inches
Beam Spacing :13.33 Feet O.C.
Number of Slab Tendons :7
Slab Tendon Spacing :6.00 Feet O.C.
Slab Tendon Centroid :2.25 Inches from top of slab
In the SHORT direction ... Type I Beam Type II Beam
Quantity of Beams : 2 3
Depth of Beams : 18.0 Inches 15.0 Inches
Width of Beams : 12.0 Inches 12.0 Inches
Tendons per Beam : 1 1
Beam Tendon Centroid : 3.25 Inches 3.25 Inches
Beam Spacing :12.75 Feet O.C.
Number of Slab Tendons :8
Slab Tendon Spacing :6.71 Feet O.C.
Slab Tendon Centroid :2.25 Inches from top of slab
Page 1 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\2. Plan 4026 -Cat I.pti 11:35:42 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4026) Cat I
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
RIBBED FOUNDATION - DESIGN COMPLIANCE SUMMARY
The BOLD values exceed allowable or are less than minimum limits by the percentage indicated:
SOIL BEARING :
SOIL BEARING: 0.0%
CENTER LIFT MODE :
ALL VALUES WITHIN ALLOWABLE LIMITS.
EDGE LIFT MODE :
ALL VALUES WITHIN ALLOWABLE LIMITS.
Page 2 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\2. Plan 4026 -Cat I.pti 11:35:42 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4026) Cat I
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
RIBBED FOUNDATION - RESULTS OF ANALYSIS
Soil Bearing Analysis
Total Applied Load 248,374 LB
Bearing Area 1,582 FT2
Applied Pressure on Soil 157 PSF
Soil Pressure Safety Factor 0.00
Prestress Summary
Subgrade Friction calculated by method prescribed in PTI Manual
Short Long
Direction Direction
Number of Slab Tendons 8 7
Number of Beam Tendons 5 4
Spacing of Slab Tendons (Feet)6.71 6.00
Center of Gravity of Concrete (from top of slab) (Inch) 3.93 4.03
Center of Gravity of Tendons (from top of slab) (Inch) 6.43 6.31
Eccentricity of Prestressing (Inch)-2.50 -2.29
Minimum Effective Prestress Force (K) 283.5 230.3
Beta Distance Effective Prestress Force (K) 321.7 274.5
Minimum Effective Prestress (PSI)82 84
Beta Distance Effective Prestress (PSI) 93 100
Moment Analysis - Center Lift Mode
Maximum Moment, Short Dir. (controlled by Em=5.0 per PTI 4.3.2) 5.57 FT-K/FT
Maximum Moment, Long Dir. (controlled by Em=5.0 per PTI 4.3.2) 5.31 FT-K/FT
Tension in Top Fiber (KSI) Compression in Bottom Fiber (KSI)
Short Long Short Long
Direction Direction Direction Direction
Allowable Stress -0.329 -0.329 Allowable Stress 1.350 1.350
Actual Stress -0.232 -0.198 Actual Stress 1.122 1.038
Stiffness Analysis - Center Lift Mode
Based on a Stiffness Coefficient of 360 Short Long
Direction Direction
Available Moment of Inertia (Inch4) 50,977 42,858
Required Moment of Inertia (Inch4) 32,754 27,385
Required Moment of Inertia controlled by Width 6*Beta
Shear Analysis - Center Lift Mode
Maximum Shear, Short Direction.1.56 K/FT
Maximum Shear, Long Direction 1.22 K/FT
Short Long
Direction Direction
Allowable Shear Stress (PSI)150 151
Actual Shear Stress (PSI)81 61
Page 3 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\2. Plan 4026 -Cat I.pti 11:35:42 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4026) Cat I
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
RIBBED FOUNDATION - RESULTS OF ANALYSIS continued
Cracked Section Analysis - Center Lift Mode
Short Long
Direction Direction
Cracked Section Capacity (FT-K)238.4 212.2
0.5 Moment (FT-K)142.2 106.2
Moment Analysis - Edge Lift Mode
Maximum Moment, Short Direction 3.28 FT-K/FT
Maximum Moment, Long Direction 3.01 FT-K/FT
Tension in Bottom Fiber (KSI) Compression in Top Fiber (KSI)
Short Long Short Long
Direction Direction Direction Direction
Allowable Stress -0.329 -0.329 Allowable Stress 1.350 1.350
Actual Stress -0.201 -0.141 Actual Stress 0.186 0.177
Stiffness Analysis - Edge Lift Mode
Based on a Stiffness Coefficient of 720 Short Long
Direction Direction
Available Moment of Inertia (Inch4) 50,977 42,858
Required Moment of Inertia (Inch4) 38,576 31,015
Required Moment of Inertia controlled by Width 6*Beta
Shear Analysis - Edge Lift Mode
Maximum Shear, Short Direction 1.50 K/FT
Maximum Shear, Long Direction 1.54 K/FT
Short Long
Direction Direction
Allowable Shear Stress (PSI)150 151
Actual Shear Stress (PSI)78 77
Cracked Section Analysis - Edge Lift Mode
Short Long
Direction Direction
Cracked Section Capacity (FT-K)145.1 118.8
0.5 Moment (FT-K)83.7 60.1
Page 4 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\2. Plan 4026 -Cat I.pti 11:35:42 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4026) Cat I
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
RIBBED FOUNDATION - SELECTED VARIABLES
Short Long
Direction Direction
Cross Sectional Area (Inch2) :3,467 2,745
Moment of Inertia (Inch4) :50,977 42,858
Section Modulus, Top (Inch3) :12,961 10,645
Section Modulus, Bottom (Inch3) : 4,097 3,388
Center of Gravity of Concrete - from top (Inch) : 3.93 4.03
Center of Gravity of Prestressing Tendons - from top (Inch) : 6.43 6.31
Eccentricity of Prestress (Inch) :-2.50 -2.29
Beta Distance (Feet) :7.79 7.46
Equivalent Beam Depth (Inches) : 16.38 16.68
Note: All Calculations above and other reported values which
depend on depths use the equivalent depths as shown above.
Jacking Force :33.05 KIPS
Page 5 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\2. Plan 4026 -Cat I.pti 11:35:42 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4026) Cat I
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
SUMMARY OF INPUT DATA
Material Properties
Concrete Strength, f'c :3,000.0 PSI
Concrete Creep Modulus, Ec : 1,500,000.0 PSI
Concrete Unit Weight :145.0 PCF
Tendon Strength, Fpu :270.0 KSI
Tendon Diameter :1 / 2 Inch
Slab Properties
Rectangle Geometry : 40.00 FT x 51.00 FT x 4.50 Inches
Short Direction Long Direction
Minimum Permissible Prestress : 80.00 PSI 80.00 PSI
Beam Properties
Short Direction Long Direction
Type I Type II Type I Type II
Quantity : 2 3 2 2
Depth : 18.0 15.0 18.0 15.0 Inches
Width : 12.0 12.0 12.0 12.0 Inches
Tendons : 1 1 1 1
Cover : 3.00 3.00 3.00 3.00 Inches
Average beam spacing used in analysis
Page 6 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\2. Plan 4026 -Cat I.pti 11:35:42 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4026) Cat I
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
SUMMARY OF INPUT DATA - Continued
Soil Properties
Allowable Bearing Pressure : 1,500.0 PSF
Center Lift Edge Lift
Edge Moisture Variation Distance, em : 9.00 Feet 4.70 Feet
Differential Soil Movement, ym : 0.350 Inches 0.650 Inches
Load, Deflection and Subgrade Properties
Slab Loading
Uniform Superimposed Total Load : 40.00 PSF
Total Perimeter Load : 1,000.00 PLF
Stiffness Coefficients
Center Lift :360
Edge Lift :720
Prestress Calculation
Subgrade Friction calculated by method prescribed in PTI Manual
Prestress Loss :15.0 KSI
Subgrade Friction Coefficient : 0.75
Page 7 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\2. Plan 4026 -Cat I.pti 11:35:42 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4026) Cat I
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
PTI EXCEPTION SUMMARY
The following elements of the design are not in strict compliance with the
Design of Post-Tensioned Slabs-On-Ground 3rd Edition manual
published by the Post-Tensioning Institute.
NO PTI EXCEPTIONS EXIST
Page 8 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\2. Plan 4026 -Cat I.pti 11:35:42 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4026) Cat I
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
LINE LOAD ANALYSIS
Summary of Input Data
Line Load :1,500.0 lb/ft
Direction Of Line Load : Parallel to Long Direction
Prestress at Line Load : Minimum Effective Prestress
Soil Modulus, Ks :40 PCI
Slab Thickness : 4.50 Inch
Concrete Creep Modulus, Ec :1,500,000.0 PSI
Summary of Line Load Analysis
Applied Moment :1.02 Ft-K/Ft
Bending Stresses (KSI)
Tension in Extreme Fiber Compression in Extreme Fiber
Allowable Stress : -0.329 1.350
Applied Stress : -0.221 0.384
Prestress at Line Load :81.8 PSI
Design Compliance Summary
The BOLD values exceed allowable or are less than minimum limits by the percentage indicated:
ALL VALUES WITHIN ALLOWABLE LIMITS.
Page 9 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\2. Plan 4026 -Cat I.pti 11:35:42 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4026) Cat I
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
RIBBED FOUNDATION - DESIGN SUMMARY
Slab Dimensions : 40.00 FT x 51.00 FT x 4.50 Inches
Material Properties
Concrete Strength, f'c :3,000 PSI
Tendon Strength, Fpu :270 KSI
Tendon Diameter :1 / 2 Inch
Material Quantities
Concrete Volume :42.6 Cubic Yards
Prestressing Tendon :1,129 Linear Feet
Number of End Anchorages :48
In the LONG direction ... Type I Beam Type II Beam
Quantity of Beams : 2 2
Depth of Beams : 18.0 Inches 15.0 Inches
Width of Beams : 12.0 Inches 12.0 Inches
Tendons per Beam : 1 1
Beam Tendon Centroid : 3.25 Inches 3.25 Inches
Beam Spacing :13.33 Feet O.C.
Number of Slab Tendons :7
Slab Tendon Spacing :6.00 Feet O.C.
Slab Tendon Centroid :2.25 Inches from top of slab
In the SHORT direction ... Type I Beam Type II Beam
Quantity of Beams : 2 3
Depth of Beams : 18.0 Inches 15.0 Inches
Width of Beams : 12.0 Inches 12.0 Inches
Tendons per Beam : 1 1
Beam Tendon Centroid : 3.25 Inches 3.25 Inches
Beam Spacing :12.75 Feet O.C.
Number of Slab Tendons :8
Slab Tendon Spacing :6.71 Feet O.C.
Slab Tendon Centroid :2.25 Inches from top of slab
Page 1 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\2. Plan 4026 -Cat II.pti 11:36:33 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4026) Cat I
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
RIBBED FOUNDATION - DESIGN COMPLIANCE SUMMARY
The BOLD values exceed allowable or are less than minimum limits by the percentage indicated:
SOIL BEARING :
SOIL BEARING: 0.0%
CENTER LIFT MODE :
ALL VALUES WITHIN ALLOWABLE LIMITS.
EDGE LIFT MODE :
ALL VALUES WITHIN ALLOWABLE LIMITS.
Page 2 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\2. Plan 4026 -Cat II.pti 11:36:33 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4026) Cat I
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
RIBBED FOUNDATION - RESULTS OF ANALYSIS
Soil Bearing Analysis
Total Applied Load 248,374 LB
Bearing Area 1,582 FT2
Applied Pressure on Soil 157 PSF
Soil Pressure Safety Factor 0.00
Prestress Summary
Subgrade Friction calculated by method prescribed in PTI Manual
Short Long
Direction Direction
Number of Slab Tendons 8 7
Number of Beam Tendons 5 4
Spacing of Slab Tendons (Feet)6.71 6.00
Center of Gravity of Concrete (from top of slab) (Inch) 3.93 4.03
Center of Gravity of Tendons (from top of slab) (Inch) 6.43 6.31
Eccentricity of Prestressing (Inch)-2.50 -2.29
Minimum Effective Prestress Force (K) 283.5 230.3
Beta Distance Effective Prestress Force (K) 321.7 274.5
Minimum Effective Prestress (PSI)82 84
Beta Distance Effective Prestress (PSI) 93 100
Moment Analysis - Center Lift Mode
Maximum Moment, Short Dir. (controlled by Em=5.0 per PTI 4.3.2) 5.85 FT-K/FT
Maximum Moment, Long Dir. (controlled by Em=5.0 per PTI 4.3.2) 5.57 FT-K/FT
Tension in Top Fiber (KSI) Compression in Bottom Fiber (KSI)
Short Long Short Long
Direction Direction Direction Direction
Allowable Stress -0.329 -0.329 Allowable Stress 1.350 1.350
Actual Stress -0.246 -0.210 Actual Stress 1.163 1.075
Stiffness Analysis - Center Lift Mode
Based on a Stiffness Coefficient of 360 Short Long
Direction Direction
Available Moment of Inertia (Inch4) 50,977 42,858
Required Moment of Inertia (Inch4) 34,382 28,746
Required Moment of Inertia controlled by Width 6*Beta
Shear Analysis - Center Lift Mode
Maximum Shear, Short Direction.1.58 K/FT
Maximum Shear, Long Direction 1.27 K/FT
Short Long
Direction Direction
Allowable Shear Stress (PSI)150 151
Actual Shear Stress (PSI)82 64
Page 3 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\2. Plan 4026 -Cat II.pti 11:36:33 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4026) Cat I
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
RIBBED FOUNDATION - RESULTS OF ANALYSIS continued
Cracked Section Analysis - Center Lift Mode
Short Long
Direction Direction
Cracked Section Capacity (FT-K)238.4 212.2
0.5 Moment (FT-K)149.2 111.5
Moment Analysis - Edge Lift Mode
Maximum Moment, Short Direction 3.51 FT-K/FT
Maximum Moment, Long Direction 3.29 FT-K/FT
Tension in Bottom Fiber (KSI) Compression in Top Fiber (KSI)
Short Long Short Long
Direction Direction Direction Direction
Allowable Stress -0.329 -0.329 Allowable Stress 1.350 1.350
Actual Stress -0.236 -0.180 Actual Stress 0.197 0.189
Stiffness Analysis - Edge Lift Mode
Based on a Stiffness Coefficient of 720 Short Long
Direction Direction
Available Moment of Inertia (Inch4) 50,977 42,858
Required Moment of Inertia (Inch4) 41,290 33,913
Required Moment of Inertia controlled by Width 6*Beta
Shear Analysis - Edge Lift Mode
Maximum Shear, Short Direction 1.76 K/FT
Maximum Shear, Long Direction 1.81 K/FT
Short Long
Direction Direction
Allowable Shear Stress (PSI)150 151
Actual Shear Stress (PSI)92 90
Cracked Section Analysis - Edge Lift Mode
Short Long
Direction Direction
Cracked Section Capacity (FT-K)145.1 118.8
0.5 Moment (FT-K)89.6 65.8
Page 4 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\2. Plan 4026 -Cat II.pti 11:36:33 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4026) Cat I
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
RIBBED FOUNDATION - SELECTED VARIABLES
Short Long
Direction Direction
Cross Sectional Area (Inch2) :3,467 2,745
Moment of Inertia (Inch4) :50,977 42,858
Section Modulus, Top (Inch3) :12,961 10,645
Section Modulus, Bottom (Inch3) : 4,097 3,388
Center of Gravity of Concrete - from top (Inch) : 3.93 4.03
Center of Gravity of Prestressing Tendons - from top (Inch) : 6.43 6.31
Eccentricity of Prestress (Inch) :-2.50 -2.29
Beta Distance (Feet) :7.79 7.46
Equivalent Beam Depth (Inches) : 16.38 16.68
Note: All Calculations above and other reported values which
depend on depths use the equivalent depths as shown above.
Jacking Force :33.05 KIPS
Page 5 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\2. Plan 4026 -Cat II.pti 11:36:33 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4026) Cat I
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
SUMMARY OF INPUT DATA
Material Properties
Concrete Strength, f'c :3,000.0 PSI
Concrete Creep Modulus, Ec : 1,500,000.0 PSI
Concrete Unit Weight :145.0 PCF
Tendon Strength, Fpu :270.0 KSI
Tendon Diameter :1 / 2 Inch
Slab Properties
Rectangle Geometry : 40.00 FT x 51.00 FT x 4.50 Inches
Short Direction Long Direction
Minimum Permissible Prestress : 80.00 PSI 80.00 PSI
Beam Properties
Short Direction Long Direction
Type I Type II Type I Type II
Quantity : 2 3 2 2
Depth : 18.0 15.0 18.0 15.0 Inches
Width : 12.0 12.0 12.0 12.0 Inches
Tendons : 1 1 1 1
Cover : 3.00 3.00 3.00 3.00 Inches
Average beam spacing used in analysis
Page 6 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\2. Plan 4026 -Cat II.pti 11:36:33 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4026) Cat I
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
SUMMARY OF INPUT DATA - Continued
Soil Properties
Allowable Bearing Pressure : 1,500.0 PSF
Center Lift Edge Lift
Edge Moisture Variation Distance, em : 8.50 Feet 4.20 Feet
Differential Soil Movement, ym : 0.450 Inches 0.850 Inches
Load, Deflection and Subgrade Properties
Slab Loading
Uniform Superimposed Total Load : 40.00 PSF
Total Perimeter Load : 1,000.00 PLF
Stiffness Coefficients
Center Lift :360
Edge Lift :720
Prestress Calculation
Subgrade Friction calculated by method prescribed in PTI Manual
Prestress Loss :15.0 KSI
Subgrade Friction Coefficient : 0.75
Page 7 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\2. Plan 4026 -Cat II.pti 11:36:33 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4026) Cat I
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
PTI EXCEPTION SUMMARY
The following elements of the design are not in strict compliance with the
Design of Post-Tensioned Slabs-On-Ground 3rd Edition manual
published by the Post-Tensioning Institute.
NO PTI EXCEPTIONS EXIST
Page 8 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\2. Plan 4026 -Cat II.pti 11:36:33 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4026) Cat I
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
LINE LOAD ANALYSIS
Summary of Input Data
Line Load :1,500.0 lb/ft
Direction Of Line Load : Parallel to Long Direction
Prestress at Line Load : Minimum Effective Prestress
Soil Modulus, Ks :40 PCI
Slab Thickness : 4.50 Inch
Concrete Creep Modulus, Ec :1,500,000.0 PSI
Summary of Line Load Analysis
Applied Moment :1.02 Ft-K/Ft
Bending Stresses (KSI)
Tension in Extreme Fiber Compression in Extreme Fiber
Allowable Stress : -0.329 1.350
Applied Stress : -0.221 0.384
Prestress at Line Load :81.8 PSI
Design Compliance Summary
The BOLD values exceed allowable or are less than minimum limits by the percentage indicated:
ALL VALUES WITHIN ALLOWABLE LIMITS.
Page 9 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\2. Plan 4026 -Cat II.pti 11:36:33 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4028) Cat I
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
RIBBED FOUNDATION - DESIGN SUMMARY
Slab Dimensions : 40.00 FT x 44.00 FT x 4.50 Inches
Material Properties
Concrete Strength, f'c :3,000 PSI
Tendon Strength, Fpu :270 KSI
Tendon Diameter :1 / 2 Inch
Material Quantities
Concrete Volume :38.0 Cubic Yards
Prestressing Tendon :1,010 Linear Feet
Number of End Anchorages :46
In the LONG direction ... Type I Beam Type II Beam
Quantity of Beams : 2 2
Depth of Beams : 18.0 Inches 15.0 Inches
Width of Beams : 12.0 Inches 12.0 Inches
Tendons per Beam : 1 1
Beam Tendon Centroid : 3.25 Inches 3.25 Inches
Beam Spacing :13.33 Feet O.C.
Number of Slab Tendons :7
Slab Tendon Spacing :6.00 Feet O.C.
Slab Tendon Centroid :2.25 Inches from top of slab
In the SHORT direction ... Type I Beam Type II Beam
Quantity of Beams : 3 2
Depth of Beams : 18.0 Inches 15.0 Inches
Width of Beams : 12.0 Inches 12.0 Inches
Tendons per Beam : 1 1
Beam Tendon Centroid : 3.25 Inches 3.25 Inches
Beam Spacing :11.00 Feet O.C.
Number of Slab Tendons :7
Slab Tendon Spacing :6.67 Feet O.C.
Slab Tendon Centroid :2.25 Inches from top of slab
Page 1 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\3. Plan 4028-Cat I.pti 11:37:06 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4028) Cat I
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
RIBBED FOUNDATION - DESIGN COMPLIANCE SUMMARY
The BOLD values exceed allowable or are less than minimum limits by the percentage indicated:
SOIL BEARING :
SOIL BEARING: 0.0%
CENTER LIFT MODE :
ALL VALUES WITHIN ALLOWABLE LIMITS.
EDGE LIFT MODE :
ALL VALUES WITHIN ALLOWABLE LIMITS.
Page 2 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\3. Plan 4028-Cat I.pti 11:37:06 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4028) Cat I
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
RIBBED FOUNDATION - RESULTS OF ANALYSIS
Soil Bearing Analysis
Total Applied Load 219,115 LB
Bearing Area 1,438 FT2
Applied Pressure on Soil 152 PSF
Soil Pressure Safety Factor 0.00
Prestress Summary
Subgrade Friction calculated by method prescribed in PTI Manual
Short Long
Direction Direction
Number of Slab Tendons 7 7
Number of Beam Tendons 5 4
Spacing of Slab Tendons (Feet)6.67 6.00
Center of Gravity of Concrete (from top of slab) (Inch) 4.28 4.03
Center of Gravity of Tendons (from top of slab) (Inch) 7.03 6.31
Eccentricity of Prestressing (Inch)-2.75 -2.29
Minimum Effective Prestress Force (K) 263.7 237.1
Beta Distance Effective Prestress Force (K) 297.4 273.9
Minimum Effective Prestress (PSI)84 86
Beta Distance Effective Prestress (PSI) 95 100
Moment Analysis - Center Lift Mode
Maximum Moment, Short Dir. (controlled by Em=5.0 per PTI 4.3.2) 5.56 FT-K/FT
Maximum Moment, Long Dir. (controlled by Em=5.0 per PTI 4.3.2) 5.30 FT-K/FT
Tension in Top Fiber (KSI) Compression in Bottom Fiber (KSI)
Short Long Short Long
Direction Direction Direction Direction
Allowable Stress -0.329 -0.329 Allowable Stress 1.350 1.350
Actual Stress -0.199 -0.198 Actual Stress 0.967 1.036
Stiffness Analysis - Center Lift Mode
Based on a Stiffness Coefficient of 360 Short Long
Direction Direction
Available Moment of Inertia (Inch4) 54,646 42,858
Required Moment of Inertia (Inch4) 28,204 26,861
Required Moment of Inertia controlled by Width Length
Shear Analysis - Center Lift Mode
Maximum Shear, Short Direction.1.47 K/FT
Maximum Shear, Long Direction 1.21 K/FT
Short Long
Direction Direction
Allowable Shear Stress (PSI)150 151
Actual Shear Stress (PSI)64 60
Page 3 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\3. Plan 4028-Cat I.pti 11:37:06 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4028) Cat I
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
RIBBED FOUNDATION - RESULTS OF ANALYSIS continued
Cracked Section Analysis - Center Lift Mode
Short Long
Direction Direction
Cracked Section Capacity (FT-K)219.1 212.2
0.5 Moment (FT-K)122.4 106.0
Moment Analysis - Edge Lift Mode
Maximum Moment, Short Direction 3.33 FT-K/FT
Maximum Moment, Long Direction 3.01 FT-K/FT
Tension in Bottom Fiber (KSI) Compression in Top Fiber (KSI)
Short Long Short Long
Direction Direction Direction Direction
Allowable Stress -0.329 -0.329 Allowable Stress 1.350 1.350
Actual Stress -0.123 -0.142 Actual Stress 0.169 0.177
Stiffness Analysis - Edge Lift Mode
Based on a Stiffness Coefficient of 720 Short Long
Direction Direction
Available Moment of Inertia (Inch4) 54,646 42,858
Required Moment of Inertia (Inch4) 33,729 30,510
Required Moment of Inertia controlled by Width Length
Shear Analysis - Edge Lift Mode
Maximum Shear, Short Direction 1.53 K/FT
Maximum Shear, Long Direction 1.52 K/FT
Short Long
Direction Direction
Allowable Shear Stress (PSI)150 151
Actual Shear Stress (PSI)66 76
Cracked Section Analysis - Edge Lift Mode
Short Long
Direction Direction
Cracked Section Capacity (FT-K)151.6 118.8
0.5 Moment (FT-K)73.2 60.2
Page 4 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\3. Plan 4028-Cat I.pti 11:37:06 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4028) Cat I
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
RIBBED FOUNDATION - SELECTED VARIABLES
Short Long
Direction Direction
Cross Sectional Area (Inch2) :3,124 2,745
Moment of Inertia (Inch4) :54,646 42,858
Section Modulus, Top (Inch3) :12,764 10,645
Section Modulus, Bottom (Inch3) : 4,308 3,388
Center of Gravity of Concrete - from top (Inch) : 4.28 4.03
Center of Gravity of Prestressing Tendons - from top (Inch) : 7.03 6.31
Eccentricity of Prestress (Inch) :-2.75 -2.29
Beta Distance (Feet) :7.93 7.46
Equivalent Beam Depth (Inches) : 16.97 16.68
Note: All Calculations above and other reported values which
depend on depths use the equivalent depths as shown above.
Jacking Force :33.05 KIPS
Page 5 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\3. Plan 4028-Cat I.pti 11:37:06 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4028) Cat I
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
SUMMARY OF INPUT DATA
Material Properties
Concrete Strength, f'c :3,000.0 PSI
Concrete Creep Modulus, Ec : 1,500,000.0 PSI
Concrete Unit Weight :145.0 PCF
Tendon Strength, Fpu :270.0 KSI
Tendon Diameter :1 / 2 Inch
Slab Properties
Rectangle Geometry : 40.00 FT x 44.00 FT x 4.50 Inches
Short Direction Long Direction
Minimum Permissible Prestress : 80.00 PSI 80.00 PSI
Beam Properties
Short Direction Long Direction
Type I Type II Type I Type II
Quantity : 3 2 2 2
Depth : 18.0 15.0 18.0 15.0 Inches
Width : 12.0 12.0 12.0 12.0 Inches
Tendons : 1 1 1 1
Cover : 3.00 3.00 3.00 3.00 Inches
Average beam spacing used in analysis
Page 6 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\3. Plan 4028-Cat I.pti 11:37:06 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4028) Cat I
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
SUMMARY OF INPUT DATA - Continued
Soil Properties
Allowable Bearing Pressure : 1,500.0 PSF
Center Lift Edge Lift
Edge Moisture Variation Distance, em : 9.00 Feet 4.70 Feet
Differential Soil Movement, ym : 0.350 Inches 0.650 Inches
Load, Deflection and Subgrade Properties
Slab Loading
Uniform Superimposed Total Load : 40.00 PSF
Total Perimeter Load : 1,000.00 PLF
Stiffness Coefficients
Center Lift :360
Edge Lift :720
Prestress Calculation
Subgrade Friction calculated by method prescribed in PTI Manual
Prestress Loss :15.0 KSI
Subgrade Friction Coefficient : 0.75
Page 7 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\3. Plan 4028-Cat I.pti 11:37:06 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4028) Cat I
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
PTI EXCEPTION SUMMARY
The following elements of the design are not in strict compliance with the
Design of Post-Tensioned Slabs-On-Ground 3rd Edition manual
published by the Post-Tensioning Institute.
NO PTI EXCEPTIONS EXIST
Page 8 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\3. Plan 4028-Cat I.pti 11:37:06 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4028) Cat I
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
LINE LOAD ANALYSIS
Summary of Input Data
Line Load :1,500.0 lb/ft
Direction Of Line Load : Parallel to Long Direction
Prestress at Line Load : Minimum Effective Prestress
Soil Modulus, Ks :40 PCI
Slab Thickness : 4.50 Inch
Concrete Creep Modulus, Ec :1,500,000.0 PSI
Summary of Line Load Analysis
Applied Moment :1.02 Ft-K/Ft
Bending Stresses (KSI)
Tension in Extreme Fiber Compression in Extreme Fiber
Allowable Stress : -0.329 1.350
Applied Stress : -0.218 0.387
Prestress at Line Load :84.4 PSI
Design Compliance Summary
The BOLD values exceed allowable or are less than minimum limits by the percentage indicated:
ALL VALUES WITHIN ALLOWABLE LIMITS.
Page 9 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\3. Plan 4028-Cat I.pti 11:37:06 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4028) Cat II
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
RIBBED FOUNDATION - DESIGN SUMMARY
Slab Dimensions : 40.00 FT x 44.00 FT x 4.50 Inches
Material Properties
Concrete Strength, f'c :3,000 PSI
Tendon Strength, Fpu :270 KSI
Tendon Diameter :1 / 2 Inch
Material Quantities
Concrete Volume :38.0 Cubic Yards
Prestressing Tendon :1,010 Linear Feet
Number of End Anchorages :46
In the LONG direction ... Type I Beam Type II Beam
Quantity of Beams : 2 2
Depth of Beams : 18.0 Inches 15.0 Inches
Width of Beams : 12.0 Inches 12.0 Inches
Tendons per Beam : 1 1
Beam Tendon Centroid : 3.25 Inches 3.25 Inches
Beam Spacing :13.33 Feet O.C.
Number of Slab Tendons :7
Slab Tendon Spacing :6.00 Feet O.C.
Slab Tendon Centroid :2.25 Inches from top of slab
In the SHORT direction ... Type I Beam Type II Beam
Quantity of Beams : 3 2
Depth of Beams : 18.0 Inches 15.0 Inches
Width of Beams : 12.0 Inches 12.0 Inches
Tendons per Beam : 1 1
Beam Tendon Centroid : 3.25 Inches 3.25 Inches
Beam Spacing :11.00 Feet O.C.
Number of Slab Tendons :7
Slab Tendon Spacing :6.67 Feet O.C.
Slab Tendon Centroid :2.25 Inches from top of slab
Page 1 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\3. Plan 4028-Cat II.pti 11:37:45 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4028) Cat II
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
RIBBED FOUNDATION - DESIGN COMPLIANCE SUMMARY
The BOLD values exceed allowable or are less than minimum limits by the percentage indicated:
SOIL BEARING :
SOIL BEARING: 0.0%
CENTER LIFT MODE :
ALL VALUES WITHIN ALLOWABLE LIMITS.
EDGE LIFT MODE :
ALL VALUES WITHIN ALLOWABLE LIMITS.
Page 2 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\3. Plan 4028-Cat II.pti 11:37:45 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4028) Cat II
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
RIBBED FOUNDATION - RESULTS OF ANALYSIS
Soil Bearing Analysis
Total Applied Load 219,115 LB
Bearing Area 1,438 FT2
Applied Pressure on Soil 152 PSF
Soil Pressure Safety Factor 0.00
Prestress Summary
Subgrade Friction calculated by method prescribed in PTI Manual
Short Long
Direction Direction
Number of Slab Tendons 7 7
Number of Beam Tendons 5 4
Spacing of Slab Tendons (Feet)6.67 6.00
Center of Gravity of Concrete (from top of slab) (Inch) 4.28 4.03
Center of Gravity of Tendons (from top of slab) (Inch) 7.03 6.31
Eccentricity of Prestressing (Inch)-2.75 -2.29
Minimum Effective Prestress Force (K) 263.7 237.1
Beta Distance Effective Prestress Force (K) 297.4 273.9
Minimum Effective Prestress (PSI)84 86
Beta Distance Effective Prestress (PSI) 95 100
Moment Analysis - Center Lift Mode
Maximum Moment, Short Dir. (controlled by Em=5.0 per PTI 4.3.2) 5.84 FT-K/FT
Maximum Moment, Long Dir. (controlled by Em=5.0 per PTI 4.3.2) 5.56 FT-K/FT
Tension in Top Fiber (KSI) Compression in Bottom Fiber (KSI)
Short Long Short Long
Direction Direction Direction Direction
Allowable Stress -0.329 -0.329 Allowable Stress 1.350 1.350
Actual Stress -0.210 -0.210 Actual Stress 1.001 1.073
Stiffness Analysis - Center Lift Mode
Based on a Stiffness Coefficient of 360 Short Long
Direction Direction
Available Moment of Inertia (Inch4) 54,646 42,858
Required Moment of Inertia (Inch4) 29,606 28,196
Required Moment of Inertia controlled by Width Length
Shear Analysis - Center Lift Mode
Maximum Shear, Short Direction.1.49 K/FT
Maximum Shear, Long Direction 1.26 K/FT
Short Long
Direction Direction
Allowable Shear Stress (PSI)150 151
Actual Shear Stress (PSI)64 63
Page 3 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\3. Plan 4028-Cat II.pti 11:37:45 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4028) Cat II
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
RIBBED FOUNDATION - RESULTS OF ANALYSIS continued
Cracked Section Analysis - Center Lift Mode
Short Long
Direction Direction
Cracked Section Capacity (FT-K)219.1 212.2
0.5 Moment (FT-K)128.5 111.3
Moment Analysis - Edge Lift Mode
Maximum Moment, Short Direction 3.56 FT-K/FT
Maximum Moment, Long Direction 3.29 FT-K/FT
Tension in Bottom Fiber (KSI) Compression in Top Fiber (KSI)
Short Long Short Long
Direction Direction Direction Direction
Allowable Stress -0.329 -0.329 Allowable Stress 1.350 1.350
Actual Stress -0.152 -0.181 Actual Stress 0.179 0.189
Stiffness Analysis - Edge Lift Mode
Based on a Stiffness Coefficient of 720 Short Long
Direction Direction
Available Moment of Inertia (Inch4) 54,646 42,858
Required Moment of Inertia (Inch4) 36,102 33,360
Required Moment of Inertia controlled by Width Length
Shear Analysis - Edge Lift Mode
Maximum Shear, Short Direction 1.79 K/FT
Maximum Shear, Long Direction 1.79 K/FT
Short Long
Direction Direction
Allowable Shear Stress (PSI)150 151
Actual Shear Stress (PSI)78 89
Cracked Section Analysis - Edge Lift Mode
Short Long
Direction Direction
Cracked Section Capacity (FT-K)151.6 118.8
0.5 Moment (FT-K)78.3 65.8
Page 4 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\3. Plan 4028-Cat II.pti 11:37:45 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4028) Cat II
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
RIBBED FOUNDATION - SELECTED VARIABLES
Short Long
Direction Direction
Cross Sectional Area (Inch2) :3,124 2,745
Moment of Inertia (Inch4) :54,646 42,858
Section Modulus, Top (Inch3) :12,764 10,645
Section Modulus, Bottom (Inch3) : 4,308 3,388
Center of Gravity of Concrete - from top (Inch) : 4.28 4.03
Center of Gravity of Prestressing Tendons - from top (Inch) : 7.03 6.31
Eccentricity of Prestress (Inch) :-2.75 -2.29
Beta Distance (Feet) :7.93 7.46
Equivalent Beam Depth (Inches) : 16.97 16.68
Note: All Calculations above and other reported values which
depend on depths use the equivalent depths as shown above.
Jacking Force :33.05 KIPS
Page 5 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\3. Plan 4028-Cat II.pti 11:37:45 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4028) Cat II
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
SUMMARY OF INPUT DATA
Material Properties
Concrete Strength, f'c :3,000.0 PSI
Concrete Creep Modulus, Ec : 1,500,000.0 PSI
Concrete Unit Weight :145.0 PCF
Tendon Strength, Fpu :270.0 KSI
Tendon Diameter :1 / 2 Inch
Slab Properties
Rectangle Geometry : 40.00 FT x 44.00 FT x 4.50 Inches
Short Direction Long Direction
Minimum Permissible Prestress : 80.00 PSI 80.00 PSI
Beam Properties
Short Direction Long Direction
Type I Type II Type I Type II
Quantity : 3 2 2 2
Depth : 18.0 15.0 18.0 15.0 Inches
Width : 12.0 12.0 12.0 12.0 Inches
Tendons : 1 1 1 1
Cover : 3.00 3.00 3.00 3.00 Inches
Average beam spacing used in analysis
Page 6 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\3. Plan 4028-Cat II.pti 11:37:45 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4028) Cat II
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
SUMMARY OF INPUT DATA - Continued
Soil Properties
Allowable Bearing Pressure : 1,500.0 PSF
Center Lift Edge Lift
Edge Moisture Variation Distance, em : 8.50 Feet 4.20 Feet
Differential Soil Movement, ym : 0.450 Inches 0.850 Inches
Load, Deflection and Subgrade Properties
Slab Loading
Uniform Superimposed Total Load : 40.00 PSF
Total Perimeter Load : 1,000.00 PLF
Stiffness Coefficients
Center Lift :360
Edge Lift :720
Prestress Calculation
Subgrade Friction calculated by method prescribed in PTI Manual
Prestress Loss :15.0 KSI
Subgrade Friction Coefficient : 0.75
Page 7 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\3. Plan 4028-Cat II.pti 11:37:45 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4028) Cat II
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
PTI EXCEPTION SUMMARY
The following elements of the design are not in strict compliance with the
Design of Post-Tensioned Slabs-On-Ground 3rd Edition manual
published by the Post-Tensioning Institute.
NO PTI EXCEPTIONS EXIST
Page 8 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\3. Plan 4028-Cat II.pti 11:37:45 AM
Build 011313
PTISlab 3.5
Geostructural Tool Kit, Inc.
Registered To : Suncoast Post-tension Serial Number : 100-350-028
Project Title : Pulte - Fairfield at Alberhill - Lake Elsinore (Plan 4028) Cat II
Project Engineer : IRW Project Number : 22-8351
Project Date : August 18, 2023
Geotechnical Report : Petra Geosciences Report Date : July 31, 2023
Report Number : J.N. 21-467
LINE LOAD ANALYSIS
Summary of Input Data
Line Load :1,500.0 lb/ft
Direction Of Line Load : Parallel to Long Direction
Prestress at Line Load : Minimum Effective Prestress
Soil Modulus, Ks :40 PCI
Slab Thickness : 4.50 Inch
Concrete Creep Modulus, Ec :1,500,000.0 PSI
Summary of Line Load Analysis
Applied Moment :1.02 Ft-K/Ft
Bending Stresses (KSI)
Tension in Extreme Fiber Compression in Extreme Fiber
Allowable Stress : -0.329 1.350
Applied Stress : -0.218 0.387
Prestress at Line Load :84.4 PSI
Design Compliance Summary
The BOLD values exceed allowable or are less than minimum limits by the percentage indicated:
ALL VALUES WITHIN ALLOWABLE LIMITS.
Page 9 of 9
\\sc2\scpt\ONT\SOG\JOBS\2022\22-8351 (Fairfield at Alberhill Ranch - Pulte)\CALCS\3. Plan 4028-Cat II.pti 11:37:45 AM
4.5" SLAB
Post 1500
Vc = 95 psi
Area = 7500 = 5 =2.24 Then use
1500
Area = 10000 = 6.666667 =2.58 Then use
1500
Area = 12500 = 8.333333 =2.89 Then use
1500
Area = 18000 = 12 =3.46 Then use
1500
Area = 24000 = 16 =4.00 Then use
1500
Area = 32000 = 21.33333 =4.62 Then use
1500
Area = 40000 = 26.66667 =5.16 Then use
1500
Area = 50000 = 33.33333 =5.77 Then use
1500
f'c=2500 psi
POST-TENSION LOADING CALCULATIONS
Post Load Capacity 4x4
bo=7.5 x 4 = 30
d=2" conservative
Allowable Bearing Capacity=
36"x36"x12Dp.
W/4#4B.E.W.
42"x42"x15Dp.
W/5#4B.E.W.
Calculations for required pads at Point Loads
30"x30"x12Dp.
W/3#4B.E.W.
No Pad Req'd.
70"x70"x22"Dp.
W/10#4B.E.W.
56"x56"x18"Dp.
W/7#4B.E.W.
62"x62"x18"Dp.
W/8#4B.E.W.
48"x48"x18"Dp.
W/6#4B.E.W.