HomeMy WebLinkAbout3.Alberhill Fairfield Energy Certs_v1CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 1 Calculation Date/Time:2023-05-31T09:12:16-07:00 (Page 1 of 14)
Calculation Description:Title 24 Analysis Input File Name:22112UP1.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-05-31 09:13:06
GENERAL INFORMATION
01 Project Name Plan 1
02 Run Title Title 24 Analysis
03 Project Location Fairfield at Alberhill Ranch
04 City Lake Elsinore 05 Standards Version 2022
06 Zip code 92530 07 Software Version EnergyPro 9.1
08 Climate Zone 10 09 Front Orientation (deg/ Cardinal)All orientations
10 Building Type Single family 11 Number of Dwelling Units 1
12 Project Scope Newly Constructed 13 Number of Bedrooms 4
14 Addition Cond. Floor Area (ft2)0 15 Number of Stories 1
16 Existing Cond. Floor Area (ft2)n/a 17 Fenestration Average U-factor 0.29
18 Total Cond. Floor Area (ft2)2191 19 Glazing Percentage (%)10.80%
20 ADU Bedroom Count n/a
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03 This building incorporates one or more Special Features shown below
423-P010092908A-000-000-0000000-0000 06/02/2023 14:47 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
REVIEWED
FOR CODE COMPLIANCE
June 30, 2023
TRB AND ASSOCIATES
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 1 Calculation Date/Time:2023-05-31T09:12:16-07:00 (Page 2 of 14)
Calculation Description:Title 24 Analysis Input File Name:22112UP1.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-05-31 09:13:06
ENERGY DESIGN RATINGS
Energy Design Ratings Compliance Margins
Source Energy
(EDR1)
Efficiency1 EDR
(EDR2efficiency)
Total2 EDR
(EDR2total)
Source Energy
(EDR1)
Efficiency1 EDR
(EDR2efficiency)
Total2 EDR
(EDR2total)
Standard Design 42.1 47.8 31.4
Proposed Design
North Facing 35.8 43.3 27 6.3 4.5 4.4
East Facing 35.9 44.3 26.6 6.2 3.5 4.8
South Facing 36.6 44.6 26.7 5.5 3.2 4.7
West Facing 36.3 43.5 26.9 5.8 4.3 4.5
RESULT3: PASS
1Efficiency EDR includes improvements like a better building envelope and more efficient equipment
2Total EDR includes efficiency and demand response measures such as photovoltaic (PV) system and batteries
3Building complies when source energy, efficiency and total compliance margins are greater than or equal to zero and unmet load hour limits are not exceeded
•Standard Design PV Capacity: 3.27 kWdc
•Proposed PV Capacity Scaling: North (3.27 kWdc) East (3.27 kWdc) South (3.27 kWdc) West (3.27 kWdc)
423-P010092908A-000-000-0000000-0000 06/02/2023 14:47 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 1 Calculation Date/Time:2023-05-31T09:12:16-07:00 (Page 3 of 14)
Calculation Description:Title 24 Analysis Input File Name:22112UP1.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-05-31 09:13:06
ENERGY USE SUMMARY
Energy Use Standard Design Source
Energy (EDR1) (kBtu/ft2 -yr)
Standard Design TDV Energy
(EDR2) (kTDV/ft2 -yr)
Proposed Design Source
Energy (EDR1) (kBtu/ft2 -yr)
Proposed Design TDV Energy
(EDR2) (kTDV/ft2 -yr)
Compliance
Margin (EDR1)
Compliance
Margin (EDR2)
Space Heating 3.3 14.73 1.22 8.54 2.08 6.19
Space Cooling 0.64 16.04 0.89 20.02 -0.25 -3.98
IAQ Ventilation 0.78 8.21 0.75 7.83 0.03 0.38
Water Heating 1.23 12.93 4.09 17.41 -2.86 -4.48
Self
Utilization/Flexibility
Credit
-6.75 6.75
North Facing
Efficiency Compliance
Total
5.95 51.91 6.95 47.05 -1 4.86
Space Heating 3.3 14.73 1.31 9.24 1.99 5.49
Space Cooling 0.64 16.04 0.9 20.37 -0.26 -4.33
IAQ Ventilation 0.78 8.21 0.75 7.83 0.03 0.38
Water Heating 1.23 12.93 4.09 17.41 -2.86 -4.48
Self
Utilization/Flexibility
Credit
-6.75 6.75
East Facing Efficiency
Compliance Total 5.95 51.91 7.05 48.1 -1.1 3.81
423-P010092908A-000-000-0000000-0000 06/02/2023 14:47 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 1 Calculation Date/Time:2023-05-31T09:12:16-07:00 (Page 4 of 14)
Calculation Description:Title 24 Analysis Input File Name:22112UP1.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-05-31 09:13:06
ENERGY USE SUMMARY
Energy Use Standard Design Source
Energy (EDR1) (kBtu/ft2 -yr)
Standard Design TDV Energy
(EDR2) (kTDV/ft2 -yr)
Proposed Design Source
Energy (EDR1) (kBtu/ft2 -yr)
Proposed Design TDV Energy
(EDR2) (kTDV/ft2 -yr)
Compliance
Margin (EDR1)
Compliance
Margin (EDR2)
Space Heating 3.3 14.73 1.51 10.68 1.79 4.05
Space Cooling 0.64 16.04 0.86 19.34 -0.22 -3.3
IAQ Ventilation 0.78 8.21 0.75 7.83 0.03 0.38
Water Heating 1.23 12.93 4.09 17.41 -2.86 -4.48
Self
Utilization/Flexibility
Credit
-6.75 6.75
South Facing
Efficiency Compliance
Total
5.95 51.91 7.21 48.51 -1.26 3.4
Space Heating 3.3 14.73 1.4 9.8 1.9 4.93
Space Cooling 0.64 16.04 0.85 18.94 -0.21 -2.9
IAQ Ventilation 0.78 8.21 0.75 7.83 0.03 0.38
Water Heating 1.23 12.93 4.09 17.41 -2.86 -4.48
Self
Utilization/Flexibility
Credit
-6.75 6.75
West Facing Efficiency
Compliance Total 5.95 51.91 7.09 47.23 -1.14 4.68
423-P010092908A-000-000-0000000-0000 06/02/2023 14:47 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 1 Calculation Date/Time:2023-05-31T09:12:16-07:00 (Page 5 of 14)
Calculation Description:Title 24 Analysis Input File Name:22112UP1.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-05-31 09:13:06
ENERGY USE INTENSITY
Standard Design (kBtu/ft2 - yr )Proposed Design (kBtu/ft2 - yr )Compliance Margin (kBtu/ft2 - yr )Margin Percentage
North Facing
Gross EUI1 16.12 17 -0.88 -5.46
Net EUI2 7.44 9.24 -1.8 -24.19
East Facing
Gross EUI1 16.12 17.05 -0.93 -5.77
Net EUI2 7.44 9.3 -1.86 -25
South Facing
Gross EUI1 16.12 17.16 -1.04 -6.45
Net EUI2 7.44 9.41 -1.97 -26.48
West Facing
Gross EUI1 16.12 17.07 -0.95 -5.89
Net EUI2 7.44 9.32 -1.88 -25.27
Notes
1. Gross EUI is Energy Use Total (not including PV) / Total Building Area.
2. Net EUI is Energy Use Total (including PV) / Total Building Area.
423-P010092908A-000-000-0000000-0000 06/02/2023 14:47 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 1 Calculation Date/Time:2023-05-31T09:12:16-07:00 (Page 6 of 14)
Calculation Description:Title 24 Analysis Input File Name:22112UP1.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-05-31 09:13:06
REQUIRED PV SYSTEMS
01 02 03 04 05 06 07 08 09 10 11 12
DC System Size
(kWdc)Exception Module Type Array Type Power Electronics CFI Azimuth
(deg)
Tilt
Input
Array Angle
(deg)
Tilt: (x in
12)
Inverter Eff.
(%)
Annual
Solar Access
(%)
3.27 NA Premium (~18-20%)Fixed Microinverters true 105-300 n/a n/a <=7:12 96 95
BATTERY SYSTEMS
01 02 03 04 05 06 07
Control Capacity (kWh)
Charging Discharging
Round Trip Efficiency
Charging Efficiency Charging Rate (kW)Discharging Efficiency Discharging Rate (kW)
TOU 10 0.96 n/a 0.96 n/a 0.9
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
•PV module type: Premium
•PV power electronics: Microinverters
•Battery System: 10 kWh (Self Utilization Credit taken)
•Indoor air quality, balanced fan
•IAQ Ventilation System: as low as 0.394118 W/CFM
•IAQ Ventilation System Heat Recovery: minimum 68 SRE and 71 ASRE
•IAQ Ventilation System: supply outside air inlet, filter, and H/ERV cores accessible per RACM Reference Manual
•Insulation below roof deck
•Window overhangs and/or fins
•Non-standard duct location (any location other than attic)
423-P010092908A-000-000-0000000-0000 06/02/2023 14:47 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 1 Calculation Date/Time:2023-05-31T09:12:16-07:00 (Page 7 of 14)
Calculation Description:Title 24 Analysis Input File Name:22112UP1.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-05-31 09:13:06
HERS FEATURE SUMMARY
The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional
detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry
•Quality insulation installation (QII)
•Indoor air quality ventilation
•Kitchen range hood
•Minimum Airflow
•Verified EER/EER2
•Verified Refrigerant Charge
•Fan Efficacy Watts/CFM
•Verified heat pump rated heating capacity
•Duct leakage testing
•Ducts located entirely in conditioned space confirmed by duct leakage testing
BUILDING - FEATURES INFORMATION
01 02 03 04 05 06 07
Project Name Conditioned Floor Area (ft2)Number of Dwelling
Units Number of Bedrooms Number of Zones Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Plan 1 2191 1 4 1 0 1
ZONE INFORMATION
01 02 03 04 05 06 07
Zone Name Zone Type HVAC System Name Zone Floor Area (ft2)Avg. Ceiling Height Water Heating System 1 Status
Plan Conditioned HVAC1 2191 9 DHW Sys 1 New
OPAQUE SURFACES
01 02 03 04 05 06 07 08
Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door
Area (ft2)Tilt (deg)
Rear Wall Plan R-15 Wall +R4.2 180 Back 360 128 90
Right Wall Plan R-15 Wall +R4.2 270 Right 396 37 90
Front Wall Plan R-15 Wall +R4.2 0 Front 180 44 90
Left Wall Plan R-15 Wall +R4.2 90 Left 594 51 90
423-P010092908A-000-000-0000000-0000 06/02/2023 14:47 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 1 Calculation Date/Time:2023-05-31T09:12:16-07:00 (Page 8 of 14)
Calculation Description:Title 24 Analysis Input File Name:22112UP1.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-05-31 09:13:06
OPAQUE SURFACES
01 02 03 04 05 06 07 08
Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door
Area (ft2)Tilt (deg)
Interior Surface Plan R-15 Wall +R4.21 n/a n/a 200 0 n/a
Roof 2 Plan R-30 Roof HPA-UV n/a n/a 2191 n/a n/a
B Wall __Garage__Garage Exterior Wall 180 Back 110 0 90
R Wall __Garage__Garage Exterior Wall 270 Right 110 0 90
F Wall __Garage__Garage Exterior Wall 0 Front 110 0 90
L Wall __Garage__Garage Exterior Wall 90 Left 110 0 90
OPAQUE SURFACES - CATHEDRAL CEILINGS
01 02 03 04 05 06 07 08 09 10 11
Name Zone Construction Azimuth Orientation Area (ft2)
Skylight Area
(ft2)
Roof Rise (x in
12)
Roof
Reflectance Roof Emittance Cool Roof
Roof __Garage__Garage Roof 0 Front 462 0 4 0.1 0.85 No
ATTIC
01 02 03 04 05 06 07 08
Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic Plan Attic RoofPlan Unventilated 5 0.1 0.85 No No
FENESTRATION / GLAZING
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Name Type Surface Orientation Azimuth Width
(ft)
Height
(ft)Mult.Area
(ft2)U-factor U-factor
Source SHGC SHGC Source Exterior Shading
SGD Window Rear Wall Back 180 6 8 1 48 0.29 NFRC 0.22 NFRC Bug Screen
Window Window Rear Wall Back 180 1 80 0.29 NFRC 0.22 NFRC Bug Screen
WindowFX Window Right Wall Right 270 1 12 0.29 NFRC 0.22 NFRC Bug Screen
423-P010092908A-000-000-0000000-0000 06/02/2023 14:47 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 1 Calculation Date/Time:2023-05-31T09:12:16-07:00 (Page 9 of 14)
Calculation Description:Title 24 Analysis Input File Name:22112UP1.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-05-31 09:13:06
FENESTRATION / GLAZING
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Name Type Surface Orientation Azimuth Width
(ft)
Height
(ft)Mult.Area
(ft2)U-factor U-factor
Source SHGC SHGC Source Exterior Shading
Window 2 Window Right Wall Right 270 1 25 0.29 NFRC 0.22 NFRC Bug Screen
Window 3 Window Front Wall Front 0 1 20 0.29 NFRC 0.22 NFRC Bug Screen
Window 4 Window Left Wall Left 90 1 20 0.29 NFRC 0.22 NFRC Bug Screen
WindowFX 2 Window Left Wall Left 90 1 31 0.29 NFRC 0.22 NFRC Bug Screen
OPAQUE DOORS
01 02 03 04
Name Side of Building Area (ft2)U-factor
Door Front Wall 24 0.102
OVERHANGS AND FINS
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Window
Overhang Left Fin Right Fin
Depth Dist Up Left Extent Right
Extent Flap Ht.Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up
SGD 8 0 1 1 0 0 0 0 0 0 0 0 0
SLAB FLOORS
01 02 03 04 05 06 07 08
Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value
and Depth
Edge Insul. R-value
and Depth Carpeted Fraction Heated
Covered Slab Plan 2191 180 none 0 80%No
Slab-on-Grade __Garage__462 0.1 none 0 0%No
423-P010092908A-000-000-0000000-0000 06/02/2023 14:47 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 1 Calculation Date/Time:2023-05-31T09:12:16-07:00 (Page 10 of 14)
Calculation Description:Title 24 Analysis Input File Name:22112UP1.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-05-31 09:13:06
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
Construction Name Surface Type Construction Type Framing Total Cavity
R-value
Interior / Exterior
Continuous
R-value
U-factor Assembly Layers
Garage Exterior Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-0 None / None 0.364
Inside Finish: Gypsum Board
Cavity / Frame: no insul. / 2x4
Exterior Finish: Synthetic Stucco
R-15 Wall +R4.2 Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-15 None / 4.2 0.063
Inside Finish: Gypsum Board
Cavity / Frame: R-15 / 2x4
Sheathing / Insulation: R-4.2 Sheathing
Exterior Finish: Synthetic Stucco
Garage Roof Cathedral Ceilings Wood Framed
Ceiling 2x4 @ 16 in. O. C.R-0 None / None 0.332
Roofing: 10 PSF (RoofTileAirGap)
Tile Gap: present
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: no insul. / 2x4
Inside Finish: Gypsum Board
R-15 Wall +R4.21 Interior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-15 None / 4.2 0.06
Inside Finish: Gypsum Board
Cavity / Frame: R-15 / 2x4
Sheathing / Insulation: R-4.2 Sheathing
Other Side Finish: Gypsum Board
Attic RoofPlan Attic Roofs Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-30 None / 0 0.04
Roofing: 10 PSF (RoofTileAirGap)
Tile Gap: present
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: R-13.0 / 2x4
Around Roof Joists: R-17.0 insul.
R-30 Roof HPA-UV Ceilings (below
attic)
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.481 Cavity / Frame: no insul. / 2x4
Inside Finish: Gypsum Board
423-P010092908A-000-000-0000000-0000 06/02/2023 14:47 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 1 Calculation Date/Time:2023-05-31T09:12:16-07:00 (Page 11 of 14)
Calculation Description:Title 24 Analysis Input File Name:22112UP1.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-05-31 09:13:06
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04 05
Quality Insulation Installation (QII)High R-value Spray Foam Insulation Building Envelope Air Leakage CFM50 CFM50
Required Not Required N/A n/a n/a
WATER HEATING SYSTEMS
01 02 03 04 05 06 07 08 09
Name System Type Distribution Type Water Heater Name Number of Units Solar Heating
System
Compact
Distribution HERS Verification Water Heater
Name (#)
DHW Sys 1 Domestic Hot
Water (DHW)Standard DHW Heater 1 1 n/a None n/a DHW Heater 1 (1)
WATER HEATERS
01 02 03 04 05 06 07 08 09 10 11 12 13
Name
Heating
Element
Type
Tank Type # of Units Tank Vol.
(gal)
Heating
Efficiency
Type
Efficiency Rated Input
Type
Input Rating
or Pilot
Tank
Insulation
R-value
(Int/Ext)
Standby Loss
or Recovery
Eff
1st Hr. Rating
or Flow Rate
Tank
Location
DHW
Heater 1 Gas
Consumer
Instantaneo
us
1 0 UEF 0.93 Btu/Hr 200000 0 n/a n/a
WATER HEATING - HERS VERIFICATION
01 02 03 04 05 06 07
Name Pipe Insulation Parallel Piping Compact Distribution Compact Distribution
Type Recirculation Control Shower Drain Water Heat
Recovery
DHW Sys 1 - 1/1 Not Required Not Required Not Required None Not Required Not Required
423-P010092908A-000-000-0000000-0000 06/02/2023 14:47 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 1 Calculation Date/Time:2023-05-31T09:12:16-07:00 (Page 12 of 14)
Calculation Description:Title 24 Analysis Input File Name:22112UP1.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-05-31 09:13:06
SPACE CONDITIONING SYSTEMS
01 02 03 04 05 06 07 08 09
Name System Type Heating Unit Name Heating Equipment
Count Cooling Unit Name Cooling Equipment
Count Fan Name Distribution Name Required
Thermostat Type
HVAC1 Heat pump
heating cooling
Heat Pump System
1 1 Heat Pump System
1 1 HVAC Fan 1 Air Distribution
System 1 Setback
HVAC - HEAT PUMPS
01 02 03 04 05 06 07 08 09 10 11 12 13
Name System Type Number of
Units
Heating Cooling
Zonally
Controlled
Compressor
Type HERS VerificationEfficiency
Type
HSPF /
HSPF2 /
COP
Cap 47 Cap 17 Efficiency
Type
SEER /
SEER2
EER /
EER /
CEER
Heat Pump
System 1 Central split HP 1 HSPF 8 24000 20000 EERSEER 15 12.5 Not Zonal Single
Speed
Heat Pump System
1-hers-htpump
HVAC HEAT PUMPS - HERS VERIFICATION
01 02 03 04 05 06 07 08 09
Name Verified Airflow Airflow Target Verified EER/EER2 Verified
SEER/SEER2
Verified Refrigerant
Charge
Verified
HSPF/HSPF2
Verified Heating
Cap 47
Verified Heating
Cap 17
Heat Pump System
1-hers-htpump Required 350 Required Not Required Yes No Yes Yes
HVAC - DISTRIBUTION SYSTEMS
01 02 03 04 05 06 07 08 09 10 11 12
Name Type Design Type
Duct Ins. R-value Duct Location Surface Area
Bypass Duct Duct Leakage HERS Verification
Supply Return Supply Return Supply Return
Air Distribution
System 1
Conditioned
space-entirely Non-Verified R-6 R-6
Conditi
oned
Zone
Conditi
oned
Zone
n/a n/a No Bypass Duct Air Distribution
System 1-hers-dist
423-P010092908A-000-000-0000000-0000 06/02/2023 14:47 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 1 Calculation Date/Time:2023-05-31T09:12:16-07:00 (Page 13 of 14)
Calculation Description:Title 24 Analysis Input File Name:22112UP1.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-05-31 09:13:06
HVAC DISTRIBUTION - HERS VERIFICATION
01 02 03 04 05 06 07 08 09
Name Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design Buried Ducts Deeply Buried
Ducts
Low-leakage Air
Handler
Low Leakage
Ducts Entirely in
Conditioned
Space
Air Distribution
System 1-hers-dist Yes 5.0 Required Not Required Not Required Credit not taken Required No
HVAC - FAN SYSTEMS
01 02 03 04
Name Type Fan Power (Watts/CFM)Name
HVAC Fan 1 HVAC Fan 0.45 HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01 02 03
Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM)
HVAC Fan 1-hers-fan Required 0.45
INDOOR AIR QUALITY (IAQ) FANS
01 02 03 04 05 06 07 08 09
Dwelling Unit Airflow (CFM)Fan Efficacy
(W/CFM)IAQ Fan Type
Includes
Heat/Energy
Recovery?
IAQ Recovery
Effectiveness - SRE
Includes Fault
Indicator Display?HERS Verification Status
SFam IAQVentRpt
1-1 170 0.394118 Balanced Yes 68 / 71 No Yes
423-P010092908A-000-000-0000000-0000 06/02/2023 14:47 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 1 Calculation Date/Time:2023-05-31T09:12:16-07:00 (Page 14 of 14)
Calculation Description:Title 24 Analysis Input File Name:22112UP1.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-05-31 09:13:06
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:Documentation Author Signature:
Company:Signature Date:
Address:CEA/ HERS Certification Identification (If applicable):
City/State/Zip:Phone:
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:Responsible Designer Signature:
Company:Date Signed:
Address:License:
City/State/Zip:Phone:
RJ Sains
Heritage Energy Group, LLC 05/31/2023
470 Wald
Irvine, CA 92618 949-584-1052
Kevin Paul
Pulte Group, Inc. - Southern CA 06/02/2023
27101 Puerta Real, Suite 300 *
Mission Viejo, CA 92691 (949) 330-8591
423-P010092908A-000-000-0000000-0000 06/02/2023 14:47 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of
this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 2 Calculation Date/Time:2023-05-31T09:21:28-07:00 (Page 1 of 15)
Calculation Description:Title 24 Analysis Input File Name:22112UP2.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-05-31 09:22:53
GENERAL INFORMATION
01 Project Name Plan 2
02 Run Title Title 24 Analysis
03 Project Location Fairfield at Alberhill Ranch
04 City Lake Elsinore 05 Standards Version 2022
06 Zip code 92530 07 Software Version EnergyPro 9.1
08 Climate Zone 10 09 Front Orientation (deg/ Cardinal)All orientations
10 Building Type Single family 11 Number of Dwelling Units 1
12 Project Scope Newly Constructed 13 Number of Bedrooms 5
14 Addition Cond. Floor Area (ft2)0 15 Number of Stories 2
16 Existing Cond. Floor Area (ft2)n/a 17 Fenestration Average U-factor 0.29
18 Total Cond. Floor Area (ft2)2654 19 Glazing Percentage (%)13.20%
20 ADU Bedroom Count n/a
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03 This building incorporates one or more Special Features shown below
423-P010092910A-000-000-0000000-0000 06/02/2023 14:47 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
REVIEWED
FOR CODE COMPLIANCE
June 30, 2023
TRB AND ASSOCIATES
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 2 Calculation Date/Time:2023-05-31T09:21:28-07:00 (Page 2 of 15)
Calculation Description:Title 24 Analysis Input File Name:22112UP2.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-05-31 09:22:53
ENERGY DESIGN RATINGS
Energy Design Ratings Compliance Margins
Source Energy
(EDR1)
Efficiency1 EDR
(EDR2efficiency)
Total2 EDR
(EDR2total)
Source Energy
(EDR1)
Efficiency1 EDR
(EDR2efficiency)
Total2 EDR
(EDR2total)
Standard Design 38.2 41.3 28.8
Proposed Design
North Facing 30 40.2 28.6 8.2 1.1 0.2
East Facing 31.4 41 28.8 6.8 0.3 0
South Facing 30.5 39.6 28.5 7.7 1.7 0.3
West Facing 29.2 38.8 28.2 9 2.5 0.6
RESULT3: PASS
1Efficiency EDR includes improvements like a better building envelope and more efficient equipment
2Total EDR includes efficiency and demand response measures such as photovoltaic (PV) system and batteries
3Building complies when source energy, efficiency and total compliance margins are greater than or equal to zero and unmet load hour limits are not exceeded
•Standard Design PV Capacity: 3.65 kWdc
•Proposed PV Capacity Scaling: North (3.65 kWdc) East (3.65 kWdc) South (3.65 kWdc) West (3.65 kWdc)
423-P010092910A-000-000-0000000-0000 06/02/2023 14:47 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 2 Calculation Date/Time:2023-05-31T09:21:28-07:00 (Page 3 of 15)
Calculation Description:Title 24 Analysis Input File Name:22112UP2.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-05-31 09:22:53
ENERGY USE SUMMARY
Energy Use Standard Design Source
Energy (EDR1) (kBtu/ft2 -yr)
Standard Design TDV Energy
(EDR2) (kTDV/ft2 -yr)
Proposed Design Source
Energy (EDR1) (kBtu/ft2 -yr)
Proposed Design TDV Energy
(EDR2) (kTDV/ft2 -yr)
Compliance
Margin (EDR1)
Compliance
Margin (EDR2)
Space Heating 2.1 9.38 2.13 9.56 -0.03 -0.18
Space Cooling 0.84 19.67 1.07 26.76 -0.23 -7.09
IAQ Ventilation 0.35 3.68 0.35 3.68 0 0
Water Heating 1.21 12.68 0.93 10.19 0.28 2.49
Self
Utilization/Flexibility
Credit
-5.9 5.9
North Facing
Efficiency Compliance
Total
4.5 45.41 4.48 44.29 0.02 1.12
Space Heating 2.1 9.38 2.59 11.66 -0.49 -2.28
Space Cooling 0.84 19.67 1.03 25.74 -0.19 -6.07
IAQ Ventilation 0.35 3.68 0.35 3.68 0 0
Water Heating 1.21 12.68 0.91 9.89 0.3 2.79
Self
Utilization/Flexibility
Credit
-5.9 5.9
East Facing Efficiency
Compliance Total 4.5 45.41 4.88 45.07 -0.38 0.34
423-P010092910A-000-000-0000000-0000 06/02/2023 14:47 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 2 Calculation Date/Time:2023-05-31T09:21:28-07:00 (Page 4 of 15)
Calculation Description:Title 24 Analysis Input File Name:22112UP2.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-05-31 09:22:53
ENERGY USE SUMMARY
Energy Use Standard Design Source
Energy (EDR1) (kBtu/ft2 -yr)
Standard Design TDV Energy
(EDR2) (kTDV/ft2 -yr)
Proposed Design Source
Energy (EDR1) (kBtu/ft2 -yr)
Proposed Design TDV Energy
(EDR2) (kTDV/ft2 -yr)
Compliance
Margin (EDR1)
Compliance
Margin (EDR2)
Space Heating 2.1 9.38 2.38 10.67 -0.28 -1.29
Space Cooling 0.84 19.67 1.01 25.28 -0.17 -5.61
IAQ Ventilation 0.35 3.68 0.35 3.68 0 0
Water Heating 1.21 12.68 0.89 9.83 0.32 2.85
Self
Utilization/Flexibility
Credit
-5.9 5.9
South Facing
Efficiency Compliance
Total
4.5 45.41 4.63 43.56 -0.13 1.85
Space Heating 2.1 9.38 1.94 8.66 0.16 0.72
Space Cooling 0.84 19.67 1.05 26.27 -0.21 -6.6
IAQ Ventilation 0.35 3.68 0.35 3.68 0 0
Water Heating 1.21 12.68 0.91 10.01 0.3 2.67
Self
Utilization/Flexibility
Credit
-5.9 5.9
West Facing Efficiency
Compliance Total 4.5 45.41 4.25 42.72 0.25 2.69
423-P010092910A-000-000-0000000-0000 06/02/2023 14:47 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 2 Calculation Date/Time:2023-05-31T09:21:28-07:00 (Page 5 of 15)
Calculation Description:Title 24 Analysis Input File Name:22112UP2.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-05-31 09:22:53
ENERGY USE INTENSITY
Standard Design (kBtu/ft2 - yr )Proposed Design (kBtu/ft2 - yr )Compliance Margin (kBtu/ft2 - yr )Margin Percentage
North Facing
Gross EUI1 13.88 14.23 -0.35 -2.52
Net EUI2 5.87 7.07 -1.2 -20.44
East Facing
Gross EUI1 13.88 14.64 -0.76 -5.48
Net EUI2 5.87 7.49 -1.62 -27.6
South Facing
Gross EUI1 13.88 14.44 -0.56 -4.03
Net EUI2 5.87 7.28 -1.41 -24.02
West Facing
Gross EUI1 13.88 14.04 -0.16 -1.15
Net EUI2 5.87 6.88 -1.01 -17.21
Notes
1. Gross EUI is Energy Use Total (not including PV) / Total Building Area.
2. Net EUI is Energy Use Total (including PV) / Total Building Area.
423-P010092910A-000-000-0000000-0000 06/02/2023 14:47 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 2 Calculation Date/Time:2023-05-31T09:21:28-07:00 (Page 6 of 15)
Calculation Description:Title 24 Analysis Input File Name:22112UP2.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-05-31 09:22:53
REQUIRED PV SYSTEMS
01 02 03 04 05 06 07 08 09 10 11 12
DC System Size
(kWdc)Exception Module Type Array Type Power Electronics CFI Azimuth
(deg)
Tilt
Input
Array Angle
(deg)
Tilt: (x in
12)
Inverter Eff.
(%)
Annual
Solar Access
(%)
3.65 NA Premium (~18-20%)Fixed Microinverters true 105-300 n/a n/a <=7:12 96 95
BATTERY SYSTEMS
01 02 03 04 05 06 07
Control Capacity (kWh)
Charging Discharging
Round Trip Efficiency
Charging Efficiency Charging Rate (kW)Discharging Efficiency Discharging Rate (kW)
Basic 9.6 0.97 n/a 0.97 n/a 0.9
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
•PV module type: Premium
•PV power electronics: Microinverters
•Battery System: 9.6 kWh (Self Utilization Credit taken)
•Floor has high level of insulation
•Window overhangs and/or fins
•Northwest Energy Efficiency Alliance (NEEA) rated heat pump water heater; specific brand/model, or equivalent, must be installed
423-P010092910A-000-000-0000000-0000 06/02/2023 14:47 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 2 Calculation Date/Time:2023-05-31T09:21:28-07:00 (Page 7 of 15)
Calculation Description:Title 24 Analysis Input File Name:22112UP2.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-05-31 09:22:53
HERS FEATURE SUMMARY
The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional
detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry
•Quality insulation installation (QII)
•Indoor air quality ventilation
•Kitchen range hood
•Minimum Airflow
•Verified EER/EER2
•Verified Refrigerant Charge
•Fan Efficacy Watts/CFM
•Duct leakage testing
•Low-leakage Air Handling Unit
BUILDING - FEATURES INFORMATION
01 02 03 04 05 06 07
Project Name Conditioned Floor Area (ft2)Number of Dwelling
Units Number of Bedrooms Number of Zones Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Plan 2 2654 1 5 1 0 1
ZONE INFORMATION
01 02 03 04 05 06 07
Zone Name Zone Type HVAC System Name Zone Floor Area (ft2)Avg. Ceiling Height Water Heating System 1 Status
Plan Conditioned HVAC1 2654 9 DHW Sys 1 New
OPAQUE SURFACES
01 02 03 04 05 06 07 08
Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door
Area (ft2)Tilt (deg)
Rear Wall Plan R-13 Wall + R4.2 180 Back 360 90 90
Right Wall Plan R-13 Wall + R4.2 270 Right 450 92.5 90
Front Wall Plan R-13 Wall + R4.2 0 Front 180 39 90
Left Wall Plan R-13 Wall + R4.2 90 Left 270 0 90
423-P010092910A-000-000-0000000-0000 06/02/2023 14:47 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 2 Calculation Date/Time:2023-05-31T09:21:28-07:00 (Page 8 of 15)
Calculation Description:Title 24 Analysis Input File Name:22112UP2.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-05-31 09:22:53
OPAQUE SURFACES
01 02 03 04 05 06 07 08
Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door
Area (ft2)Tilt (deg)
Rear Wall 2 Plan R-13 Wall + R4.2 180 Back 320 48 90
Right Wall 2 Plan R-13 Wall + R4.2 270 Right 368 25 90
Front Wall 2 Plan R-13 Wall + R4.2 0 Front 320 49 90
Left Wall 2 Plan R-13 Wall + R4.2 90 Left 368 30 90
Interior Surface Plan INT R-15 n/a n/a 369 0 n/a
Roof 2 Plan R-38 Roof Attic RB n/a n/a 1502 n/a n/a
Raised Floor Plan R-30 Floor No Crawlspace n/a n/a 370 n/a n/a
B Wall __Garage__Garage Exterior Wall 180 Back 110 0 90
R Wall __Garage__Garage Exterior Wall 270 Right 110 0 90
F Wall __Garage__Garage Exterior Wall 0 Front 110 0 90
L Wall __Garage__Garage Exterior Wall 90 Left 110 0 90
OPAQUE SURFACES - CATHEDRAL CEILINGS
01 02 03 04 05 06 07 08 09 10 11
Name Zone Construction Azimuth Orientation Area (ft2)
Skylight Area
(ft2)
Roof Rise (x in
12)
Roof
Reflectance Roof Emittance Cool Roof
Roof __Garage__Garage Roof 0 Front 426 0 4 0.1 0.85 No
ATTIC
01 02 03 04 05 06 07 08
Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic Plan Attic RoofPlan Ventilated 5 0.1 0.85 Yes No
423-P010092910A-000-000-0000000-0000 06/02/2023 14:47 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 2 Calculation Date/Time:2023-05-31T09:21:28-07:00 (Page 9 of 15)
Calculation Description:Title 24 Analysis Input File Name:22112UP2.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-05-31 09:22:53
FENESTRATION / GLAZING
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Name Type Surface Orientation Azimuth Width
(ft)
Height
(ft)Mult.Area
(ft2)U-factor U-factor
Source SHGC SHGC Source Exterior Shading
Window Window Rear Wall Back 180 1 60 0.29 NFRC 0.22 NFRC Bug Screen
Window 2 Window Rear Wall Back 180 6 5 1 30 0.29 NFRC 0.22 NFRC Bug Screen
WindowFX Window Right Wall Right 270 1 28.5 0.29 NFRC 0.22 NFRC Bug Screen
SGD Window Right Wall Right 270 1 64 0.29 NFRC 0.22 NFRC Bug Screen
Window 3 Window Front Wall Front 0 1 15 0.29 NFRC 0.22 NFRC Bug Screen
Window 4 Window Rear Wall 2 Back 180 1 44 0.29 NFRC 0.22 NFRC Bug Screen
WindowFX 2 Window Rear Wall 2 Back 180 5 4 0 4 0.29 NFRC 0.22 NFRC Bug Screen
Window 5 Window Right Wall 2 Right 270 1 25 0.29 NFRC 0.22 NFRC Bug Screen
Window 6 Window Front Wall 2 Front 0 1 40 0.29 NFRC 0.22 NFRC Bug Screen
WindowFX 3 Window Front Wall 2 Front 0 1 9 0.29 NFRC 0.22 NFRC Bug Screen
Window 7 Window Left Wall 2 Left 90 1 20 0.29 NFRC 0.22 NFRC Bug Screen
WindowFX 4 Window Left Wall 2 Left 90 1 10 0.29 NFRC 0.22 NFRC Bug Screen
OPAQUE DOORS
01 02 03 04
Name Side of Building Area (ft2)U-factor
Door Front Wall 24 0.102
423-P010092910A-000-000-0000000-0000 06/02/2023 14:47 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 2 Calculation Date/Time:2023-05-31T09:21:28-07:00 (Page 10 of 15)
Calculation Description:Title 24 Analysis Input File Name:22112UP2.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-05-31 09:22:53
OVERHANGS AND FINS
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Window
Overhang Left Fin Right Fin
Depth Dist Up Left Extent Right
Extent Flap Ht.Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up
Window 2 10 0 1 5 5 0 0 0 0 0 0 0 0
WindowFX 2 1.5 0.5 6 6 0 0 0 0 0 0 0 0 0
SLAB FLOORS
01 02 03 04 05 06 07 08
Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value
and Depth
Edge Insul. R-value
and Depth Carpeted Fraction Heated
Covered Slab Plan 1152 127 none 0 80%No
Slab-on-Grade __Garage__417 0.1 none 0 0%No
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
Construction Name Surface Type Construction Type Framing Total Cavity
R-value
Interior / Exterior
Continuous
R-value
U-factor Assembly Layers
Garage Exterior Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-0 None / None 0.364
Inside Finish: Gypsum Board
Cavity / Frame: no insul. / 2x4
Exterior Finish: Synthetic Stucco
R-13 Wall + R4.2 Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-13 None / 4.2 0.067
Inside Finish: Gypsum Board
Cavity / Frame: R-13 / 2x4
Sheathing / Insulation: R-4.2 Sheathing
Exterior Finish: Synthetic Stucco
423-P010092910A-000-000-0000000-0000 06/02/2023 14:47 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 2 Calculation Date/Time:2023-05-31T09:21:28-07:00 (Page 11 of 15)
Calculation Description:Title 24 Analysis Input File Name:22112UP2.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-05-31 09:22:53
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
Construction Name Surface Type Construction Type Framing Total Cavity
R-value
Interior / Exterior
Continuous
R-value
U-factor Assembly Layers
Garage Roof Cathedral Ceilings Wood Framed
Ceiling 2x4 @ 16 in. O. C.R-0 None / None 0.332
Roofing: 10 PSF (RoofTileAirGap)
Tile Gap: present
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: no insul. / 2x4
Inside Finish: Gypsum Board
INT R-15 Interior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-15 None / None 0.086
Inside Finish: Gypsum Board
Cavity / Frame: R-15 / 2x4
Other Side Finish: Gypsum Board
Attic RoofPlan Attic Roofs Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-0 None / 0 0.4
Roofing: 10 PSF (RoofTileAirGap)
Tile Gap: present
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: no insul. / 2x4
R-38 Roof Attic RB Ceilings (below
attic)
Wood Framed
Ceiling 2x4 @ 16 in. O. C.R-38 None / None 0.025
Over Ceiling Joists: R-28.9 insul.
Cavity / Frame: R-9.1 / 2x4
Inside Finish: Gypsum Board
R-30 Floor No
Crawlspace Exterior Floors Wood Framed Floor 2x10 @ 24 in. O. C.R-30 None / None 0.033
Floor Surface: Carpeted
Floor Deck: Wood
Siding/sheathing/decking
Cavity / Frame: R-30 / 2x10
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04 05
Quality Insulation Installation (QII)High R-value Spray Foam Insulation Building Envelope Air Leakage CFM50 CFM50
Required Not Required N/A n/a n/a
423-P010092910A-000-000-0000000-0000 06/02/2023 14:47 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 2 Calculation Date/Time:2023-05-31T09:21:28-07:00 (Page 12 of 15)
Calculation Description:Title 24 Analysis Input File Name:22112UP2.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-05-31 09:22:53
WATER HEATING SYSTEMS
01 02 03 04 05 06 07 08 09
Name System Type Distribution Type Water Heater Name Number of Units Solar Heating
System
Compact
Distribution HERS Verification Water Heater
Name (#)
DHW Sys 1 Domestic Hot
Water (DHW)Standard DHW Heater 1 1 n/a None n/a DHW Heater 1 (1)
WATER HEATERS - NEEA HEAT PUMP
01 02 03 04 05 06 07 08
Name # of Units Tank Vol. (gal)NEEA Heat Pump
Brand
NEEA Heat Pump
Model Tank Location Duct Inlet Air Source Duct Outlet Air Source
DHW Heater 1 1 65 Rheem RheemPROPH65RH3
50DCB __Garage____Garage____Garage__
WATER HEATING - HERS VERIFICATION
01 02 03 04 05 06 07
Name Pipe Insulation Parallel Piping Compact Distribution Compact Distribution
Type Recirculation Control Shower Drain Water Heat
Recovery
DHW Sys 1 - 1/1 Not Required Not Required Not Required None Not Required Not Required
SPACE CONDITIONING SYSTEMS
01 02 03 04 05 06 07 08 09
Name System Type Heating Unit Name Heating Equipment
Count Cooling Unit Name Cooling Equipment
Count Fan Name Distribution Name Required
Thermostat Type
HVAC1
Heating and
cooling system
other
Heating
Component 1 1 Cooling
Component 1 1 HVAC Fan 1 Air Distribution
System 1 Setback
423-P010092910A-000-000-0000000-0000 06/02/2023 14:47 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 2 Calculation Date/Time:2023-05-31T09:21:28-07:00 (Page 13 of 15)
Calculation Description:Title 24 Analysis Input File Name:22112UP2.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-05-31 09:22:53
HVAC - HEATING UNIT TYPES
01 02 03 04
Name System Type Number of Units Heating Efficiency
Heating Component 1 Central gas furnace 1 AFUE-95
HVAC - COOLING UNIT TYPES
01 02 03 04 05 06 07 08 09
Name System Type Number of Units Efficiency Metric Efficiency
EER/EER2/CEER
Efficiency
SEER/SEER2 Zonally Controlled Mulit-speed
Compressor HERS Verification
Cooling
Component 1 Central split AC 1 EER/SEER 12.5 15 Zonally Controlled Single Speed
Cooling
Component
1-hers-cool
HVAC COOLING - HERS VERIFICATION
01 02 03 04 05 06
Name Verified Airflow Airflow Target Verified EER/EER2 Verified SEERSEER2 Verified Refrigerant Charge
Cooling Component
1-hers-cool Required 275 Required Not Required Required
HVAC - DISTRIBUTION SYSTEMS
01 02 03 04 05 06 07 08 09 10 11 12
Name Type Design Type
Duct Ins. R-value Duct Location Surface Area
Bypass Duct Duct Leakage HERS Verification
Supply Return Supply Return Supply Return
Air Distribution
System 1
Unconditioned
attic Non-Verified R-6 R-6 Attic Attic n/a n/a No Bypass Duct Air Distribution
System 1-hers-dist
423-P010092910A-000-000-0000000-0000 06/02/2023 14:47 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 2 Calculation Date/Time:2023-05-31T09:21:28-07:00 (Page 14 of 15)
Calculation Description:Title 24 Analysis Input File Name:22112UP2.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-05-31 09:22:53
HVAC DISTRIBUTION - HERS VERIFICATION
01 02 03 04 05 06 07 08 09
Name Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design Buried Ducts Deeply Buried
Ducts
Low-leakage Air
Handler
Low Leakage
Ducts Entirely in
Conditioned
Space
Air Distribution
System 1-hers-dist Yes 5.0 Not Required Not Required Not Required Credit not taken Required No
HVAC - FAN SYSTEMS
01 02 03 04
Name Type Fan Power (Watts/CFM)Name
HVAC Fan 1 HVAC Fan 0.45 HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01 02 03
Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM)
HVAC Fan 1-hers-fan Required 0.45
INDOOR AIR QUALITY (IAQ) FANS
01 02 03 04 05 06 07 08 09
Dwelling Unit Airflow (CFM)Fan Efficacy
(W/CFM)IAQ Fan Type
Includes
Heat/Energy
Recovery?
IAQ Recovery
Effectiveness - SRE
Includes Fault
Indicator Display?HERS Verification Status
SFam IAQVentRpt 120 0.35 Exhaust No n/a / n/a No Yes
423-P010092910A-000-000-0000000-0000 06/02/2023 14:47 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 2 Calculation Date/Time:2023-05-31T09:21:28-07:00 (Page 15 of 15)
Calculation Description:Title 24 Analysis Input File Name:22112UP2.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-05-31 09:22:53
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:Documentation Author Signature:
Company:Signature Date:
Address:CEA/ HERS Certification Identification (If applicable):
City/State/Zip:Phone:
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:Responsible Designer Signature:
Company:Date Signed:
Address:License:
City/State/Zip:Phone:
RJ Sains
Heritage Energy Group, LLC 05/31/2023
470 Wald
Irvine, CA 92618 949-584-1052
Kevin Paul
Pulte Group, Inc. - Southern CA 06/02/2023
27101 Puerta Real, Suite 300 *
Mission Viejo, CA 92691 (949) 330-8591
423-P010092910A-000-000-0000000-0000 06/02/2023 14:47 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of
this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 3 Calculation Date/Time:2023-03-10T08:50:33-08:00 (Page 1 of 16)
Calculation Description:Title 24 Analysis Input File Name:22112UP3.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-03-10 08:52:33
GENERAL INFORMATION
01 Project Name Plan 3
02 Run Title Title 24 Analysis
03 Project Location Fairfield at Alberhill Ranch
04 City Lake Elsinore 05 Standards Version 2022
06 Zip code 92530 07 Software Version EnergyPro 9.1
08 Climate Zone 10 09 Front Orientation (deg/ Cardinal)All orientations
10 Building Type Single family 11 Number of Dwelling Units 1
12 Project Scope Newly Constructed 13 Number of Bedrooms 5
14 Addition Cond. Floor Area (ft2)0 15 Number of Stories 2
16 Existing Cond. Floor Area (ft2)n/a 17 Fenestration Average U-factor 0.29
18 Total Cond. Floor Area (ft2)2824 19 Glazing Percentage (%)12.60%
20 ADU Bedroom Count n/a
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03 This building incorporates one or more Special Features shown below
423-P010041798A-000-000-0000000-0000 03/10/2023 15:44 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
REVIEWED
FOR CODE COMPLIANCE
June 30, 2023
TRB AND ASSOCIATES
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 3 Calculation Date/Time:2023-03-10T08:50:33-08:00 (Page 2 of 16)
Calculation Description:Title 24 Analysis Input File Name:22112UP3.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-03-10 08:52:33
ENERGY DESIGN RATINGS
Energy Design Ratings Compliance Margins
Source Energy
(EDR1)
Efficiency1 EDR
(EDR2efficiency)
Total2 EDR
(EDR2total)
Source Energy
(EDR1)
Efficiency1 EDR
(EDR2efficiency)
Total2 EDR
(EDR2total)
Standard Design 38.2 41.5 28.7
Proposed Design
North Facing 29.5 38.7 27.2 8.7 2.8 1.5
East Facing 31.3 41.4 28.7 6.9 0.1 0
South Facing 30.8 39.5 27.6 7.4 2 1.1
West Facing 30.4 40.1 28.4 7.8 1.4 0.3
RESULT3: PASS
1Efficiency EDR includes improvements like a better building envelope and more efficient equipment
2Total EDR includes efficiency and demand response measures such as photovoltaic (PV) system and batteries
3Building complies when source energy, efficiency and total compliance margins are greater than or equal to zero and unmet load hour limits are not exceeded
•Standard Design PV Capacity: 3.68 kWdc
423-P010041798A-000-000-0000000-0000 03/10/2023 15:44 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 3 Calculation Date/Time:2023-03-10T08:50:33-08:00 (Page 3 of 16)
Calculation Description:Title 24 Analysis Input File Name:22112UP3.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-03-10 08:52:33
ENERGY USE SUMMARY
Energy Use Standard Design Source
Energy (EDR1) (kBtu/ft2 -yr)
Standard Design TDV Energy
(EDR2) (kTDV/ft2 -yr)
Proposed Design Source
Energy (EDR1) (kBtu/ft2 -yr)
Proposed Design TDV Energy
(EDR2) (kTDV/ft2 -yr)
Compliance
Margin (EDR1)
Compliance
Margin (EDR2)
Space Heating 2.15 9.6 2.2 9.85 -0.05 -0.25
Space Cooling 0.79 18.53 0.93 23.39 -0.14 -4.86
IAQ Ventilation 0.34 3.59 0.34 3.59 0 0
Water Heating 1.14 11.91 0.87 9.54 0.27 2.37
Self
Utilization/Flexibility
Credit
-5.67 5.67
North Facing
Efficiency Compliance
Total
4.42 43.63 4.34 40.7 0.08 2.93
Space Heating 2.15 9.6 2.55 11.42 -0.4 -1.82
Space Cooling 0.79 18.53 0.99 24.84 -0.2 -6.31
IAQ Ventilation 0.34 3.59 0.34 3.59 0 0
Water Heating 1.14 11.91 0.85 9.27 0.29 2.64
Self
Utilization/Flexibility
Credit
-5.67 5.67
East Facing Efficiency
Compliance Total 4.42 43.63 4.73 43.45 -0.31 0.18
423-P010041798A-000-000-0000000-0000 03/10/2023 15:44 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 3 Calculation Date/Time:2023-03-10T08:50:33-08:00 (Page 4 of 16)
Calculation Description:Title 24 Analysis Input File Name:22112UP3.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-03-10 08:52:33
ENERGY USE SUMMARY
Energy Use Standard Design Source
Energy (EDR1) (kBtu/ft2 -yr)
Standard Design TDV Energy
(EDR2) (kTDV/ft2 -yr)
Proposed Design Source
Energy (EDR1) (kBtu/ft2 -yr)
Proposed Design TDV Energy
(EDR2) (kTDV/ft2 -yr)
Compliance
Margin (EDR1)
Compliance
Margin (EDR2)
Space Heating 2.15 9.6 2.55 11.44 -0.4 -1.84
Space Cooling 0.79 18.53 0.91 22.92 -0.12 -4.39
IAQ Ventilation 0.34 3.59 0.34 3.59 0 0
Water Heating 1.14 11.91 0.84 9.23 0.3 2.68
Self
Utilization/Flexibility
Credit
-5.67 5.67
South Facing
Efficiency Compliance
Total
4.42 43.63 4.64 41.51 -0.22 2.12
Space Heating 2.15 9.6 2.31 10.33 -0.16 -0.73
Space Cooling 0.79 18.53 0.98 24.49 -0.19 -5.96
IAQ Ventilation 0.34 3.59 0.34 3.59 0 0
Water Heating 1.14 11.91 0.85 9.38 0.29 2.53
Self
Utilization/Flexibility
Credit
-5.67 5.67
West Facing Efficiency
Compliance Total 4.42 43.63 4.48 42.12 -0.06 1.51
423-P010041798A-000-000-0000000-0000 03/10/2023 15:44 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 3 Calculation Date/Time:2023-03-10T08:50:33-08:00 (Page 5 of 16)
Calculation Description:Title 24 Analysis Input File Name:22112UP3.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-03-10 08:52:33
ENERGY USE INTENSITY
Standard Design (kBtu/ft2 - yr )Proposed Design (kBtu/ft2 - yr )Compliance Margin (kBtu/ft2 - yr )Margin Percentage
North Facing
Gross EUI1 13.31 13.48 -0.17 -1.28
Net EUI2 5.72 6.67 -0.95 -16.61
East Facing
Gross EUI1 13.31 13.97 -0.66 -4.96
Net EUI2 5.72 7.16 -1.44 -25.17
South Facing
Gross EUI1 13.31 13.83 -0.52 -3.91
Net EUI2 5.72 7.02 -1.3 -22.73
West Facing
Gross EUI1 13.31 13.75 -0.44 -3.31
Net EUI2 5.72 6.94 -1.22 -21.33
Notes
1. Gross EUI is Energy Use Total (not including PV) / Total Building Area.
2. Net EUI is Energy Use Total (including PV) / Total Building Area.
423-P010041798A-000-000-0000000-0000 03/10/2023 15:44 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 3 Calculation Date/Time:2023-03-10T08:50:33-08:00 (Page 6 of 16)
Calculation Description:Title 24 Analysis Input File Name:22112UP3.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-03-10 08:52:33
REQUIRED PV SYSTEMS
01 02 03 04 05 06 07 08 09 10 11 12
DC System Size
(kWdc)Exception Module Type Array Type Power Electronics CFI Azimuth
(deg)
Tilt
Input
Array Angle
(deg)
Tilt: (x in
12)
Inverter Eff.
(%)
Annual
Solar Access
(%)
3.7 NA Premium (~18-20%)Fixed Microinverters true 105-300 n/a n/a <=7:12 96 95
BATTERY SYSTEMS
01 02 03 04 05 06 07
Control Capacity (kWh)
Charging Discharging
Round Trip Efficiency
Charging Efficiency Charging Rate (kW)Discharging Efficiency Discharging Rate (kW)
Basic 9.6 0.97 n/a 0.97 n/a 0.9
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
•PV module type: Premium
•PV power electronics: Microinverters
•Battery System: 9.6 kWh (Self Utilization Credit taken)
•Floor has high level of insulation
•Window overhangs and/or fins
•Northwest Energy Efficiency Alliance (NEEA) rated heat pump water heater; specific brand/model, or equivalent, must be installed
423-P010041798A-000-000-0000000-0000 03/10/2023 15:44 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 3 Calculation Date/Time:2023-03-10T08:50:33-08:00 (Page 7 of 16)
Calculation Description:Title 24 Analysis Input File Name:22112UP3.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-03-10 08:52:33
HERS FEATURE SUMMARY
The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional
detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry
•Quality insulation installation (QII)
•Indoor air quality ventilation
•Kitchen range hood
•Minimum Airflow
•Verified EER/EER2
•Verified Refrigerant Charge
•Fan Efficacy Watts/CFM
•Duct leakage testing
•Low-leakage Air Handling Unit
BUILDING - FEATURES INFORMATION
01 02 03 04 05 06 07
Project Name Conditioned Floor Area (ft2)Number of Dwelling
Units Number of Bedrooms Number of Zones Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Plan 3 2824 1 5 1 0 1
ZONE INFORMATION
01 02 03 04 05 06 07
Zone Name Zone Type HVAC System Name Zone Floor Area (ft2)Avg. Ceiling Height Water Heating System 1 Status
Plan3 Conditioned HVAC1 2824 9 DHW Sys 1 New
OPAQUE SURFACES
01 02 03 04 05 06 07 08
Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door
Area (ft2)Tilt (deg)
Rear Wall 2x6 Plan3 R-21 Wall + R4.2 180 Back 360 124 90
Right Wall Plan3 R-13 Wall + R4.2 270 Right 414 20 90
Front Wall Plan3 R-13 Wall + R4.2 0 Front 180 30 90
Left Wall Plan3 R-13 Wall + R4.2 90 Left 234 8 90
423-P010041798A-000-000-0000000-0000 03/10/2023 15:44 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 3 Calculation Date/Time:2023-03-10T08:50:33-08:00 (Page 8 of 16)
Calculation Description:Title 24 Analysis Input File Name:22112UP3.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-03-10 08:52:33
OPAQUE SURFACES
01 02 03 04 05 06 07 08
Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door
Area (ft2)Tilt (deg)
Rear Wall Plan3 R-13 Wall + R4.2 180 Back 360 62 90
Right Wall 2 Plan3 R-13 Wall + R4.2 270 Right 396 27 90
Front Wall 2 Plan3 R-13 Wall + R4.2 0 Front 360 60 90
Left Wall 2 Plan3 R-13 Wall + R4.2 90 Left 396 26 90
Interior Surface Plan3 R-13 INT n/a n/a 360 0 n/a
Roof 2 Plan3 R-38 Roof Attic RB n/a n/a 1581 n/a n/a
Raised Floor Plan3 R-30 Floor No Crawlspace n/a n/a 325 n/a n/a
B Wall __Garage__Garage Exterior Wall 180 Back 110 0 90
R Wall __Garage__Garage Exterior Wall 270 Right 110 0 90
F Wall __Garage__Garage Exterior Wall 0 Front 110 0 90
L Wall __Garage__Garage Exterior Wall 90 Left 110 0 90
OPAQUE SURFACES - CATHEDRAL CEILINGS
01 02 03 04 05 06 07 08 09 10 11
Name Zone Construction Azimuth Orientation Area (ft2)
Skylight Area
(ft2)
Roof Rise (x in
12)
Roof
Reflectance Roof Emittance Cool Roof
Roof __Garage__Garage Roof 0 Front 443 0 4 0.1 0.85 No
ATTIC
01 02 03 04 05 06 07 08
Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic Plan3 Attic RoofPlan3 Ventilated 5 0.1 0.85 Yes No
423-P010041798A-000-000-0000000-0000 03/10/2023 15:44 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 3 Calculation Date/Time:2023-03-10T08:50:33-08:00 (Page 9 of 16)
Calculation Description:Title 24 Analysis Input File Name:22112UP3.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-03-10 08:52:33
FENESTRATION / GLAZING
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Name Type Surface Orientation Azimuth Width
(ft)
Height
(ft)Mult.Area
(ft2)U-factor U-factor
Source SHGC SHGC Source Exterior Shading
SGD Window Rear Wall 2x6 Back 180 8 8 1 64 0.29 NFRC 0.22 NFRC Bug Screen
Window Window Rear Wall 2x6 Back 180 1 60 0.29 NFRC 0.22 NFRC Bug Screen
WindowFX Window Right Wall Right 270 1 20 0.29 NFRC 0.22 NFRC Bug Screen
Window 2 Window Front Wall Front 0 1 30 0.29 NFRC 0.2 NFRC Bug Screen
Window 3 Window Left Wall Left 90 1 8 0.29 NFRC 0.22 NFRC Bug Screen
Window 4 Window Rear Wall Back 180 5 4 1 20 0.29 NFRC 0.22 NFRC Bug Screen
Window 5 Window Rear Wall Back 180 8 4 1 32 0.29 NFRC 0.22 NFRC Bug Screen
WindowFX 2 Window Rear Wall Back 180 1 10 0.29 NFRC 0.22 NFRC Bug Screen
WindowFX 3 Window Right Wall 2 Right 270 1 6 0.29 NFRC 0.22 NFRC Bug Screen
Window 6 Window Right Wall 2 Right 270 5.25 4 1 21 0.29 NFRC 0.22 NFRC Bug Screen
Window 7 Window Front Wall 2 Front 0 12 5 1 60 0.29 NFRC 0.2 NFRC Bug Screen
Window 8 Window Left Wall 2 Left 90 1 6 0.29 NFRC 0.22 NFRC Bug Screen
WindowFX 4 Window Left Wall 2 Left 90 1 20 0.29 NFRC 0.22 NFRC Bug Screen
423-P010041798A-000-000-0000000-0000 03/10/2023 15:44 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 3 Calculation Date/Time:2023-03-10T08:50:33-08:00 (Page 10 of 16)
Calculation Description:Title 24 Analysis Input File Name:22112UP3.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-03-10 08:52:33
OVERHANGS AND FINS
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Window
Overhang Left Fin Right Fin
Depth Dist Up Left Extent Right
Extent Flap Ht.Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up
SGD 10 0 2 2 0 0 0 0 0 0 0 0 0
Window 4 1.5 0.5 5 5 0 0 0 0 0 0 0 0 0
Window 5 1.5 0.5 5 5 0 0 0 0 0 0 0 0 0
Window 6 1.5 0.5 5 5 0 0 0 0 0 0 0 0 0
Window 7 1.5 0.5 5 5 0 0 0 0 0 0 0 0 0
SLAB FLOORS
01 02 03 04 05 06 07 08
Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value
and Depth
Edge Insul. R-value
and Depth Carpeted Fraction Heated
Covered Slab Plan3 1243 170 none 0 80%No
Slab-on-Grade __Garage__443 0.1 none 0 0%No
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
Construction Name Surface Type Construction Type Framing Total Cavity
R-value
Interior / Exterior
Continuous
R-value
U-factor Assembly Layers
Garage Exterior Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-0 None / None 0.364
Inside Finish: Gypsum Board
Cavity / Frame: no insul. / 2x4
Exterior Finish: Synthetic Stucco
423-P010041798A-000-000-0000000-0000 03/10/2023 15:44 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 3 Calculation Date/Time:2023-03-10T08:50:33-08:00 (Page 11 of 16)
Calculation Description:Title 24 Analysis Input File Name:22112UP3.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-03-10 08:52:33
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
Construction Name Surface Type Construction Type Framing Total Cavity
R-value
Interior / Exterior
Continuous
R-value
U-factor Assembly Layers
R-21 Wall + R4.2 Exterior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / 4.2 0.05
Inside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
Sheathing / Insulation: R-4.2 Sheathing
Exterior Finish: Synthetic Stucco
R-13 Wall + R4.2 Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-13 None / 4.2 0.067
Inside Finish: Gypsum Board
Cavity / Frame: R-13 / 2x4
Sheathing / Insulation: R-4.2 Sheathing
Exterior Finish: Synthetic Stucco
Garage Roof Cathedral Ceilings Wood Framed
Ceiling 2x4 @ 16 in. O. C.R-0 None / None 0.332
Roofing: 10 PSF (RoofTileAirGap)
Tile Gap: present
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: no insul. / 2x4
Inside Finish: Gypsum Board
R-13 INT Interior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-13 None / None 0.092
Inside Finish: Gypsum Board
Cavity / Frame: R-13 / 2x4
Other Side Finish: Gypsum Board
Attic RoofPlan3 Attic Roofs Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-0 None / 0 0.4
Roofing: 10 PSF (RoofTileAirGap)
Tile Gap: present
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: no insul. / 2x4
R-38 Roof Attic RB Ceilings (below
attic)
Wood Framed
Ceiling 2x4 @ 16 in. O. C.R-38 None / None 0.025
Over Ceiling Joists: R-28.9 insul.
Cavity / Frame: R-9.1 / 2x4
Inside Finish: Gypsum Board
R-30 Floor No
Crawlspace Exterior Floors Wood Framed Floor 2x10 @ 24 in. O. C.R-30 None / None 0.033
Floor Surface: Carpeted
Floor Deck: Wood
Siding/sheathing/decking
Cavity / Frame: R-30 / 2x10
423-P010041798A-000-000-0000000-0000 03/10/2023 15:44 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 3 Calculation Date/Time:2023-03-10T08:50:33-08:00 (Page 12 of 16)
Calculation Description:Title 24 Analysis Input File Name:22112UP3.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-03-10 08:52:33
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04 05
Quality Insulation Installation (QII)High R-value Spray Foam Insulation Building Envelope Air Leakage CFM50 CFM50
Required Not Required N/A n/a n/a
WATER HEATING SYSTEMS
01 02 03 04 05 06 07 08 09
Name System Type Distribution Type Water Heater Name Number of Units Solar Heating
System
Compact
Distribution HERS Verification Water Heater
Name (#)
DHW Sys 1 Domestic Hot
Water (DHW)Standard DHW Heater 1 1 n/a None n/a DHW Heater 1 (1)
WATER HEATERS - NEEA HEAT PUMP
01 02 03 04 05 06 07 08
Name # of Units Tank Vol. (gal)NEEA Heat Pump
Brand
NEEA Heat Pump
Model Tank Location Duct Inlet Air Source Duct Outlet Air Source
DHW Heater 1 1 65 Rheem RheemPROPH65RH3
50DCB __Garage____Garage____Garage__
WATER HEATING - HERS VERIFICATION
01 02 03 04 05 06 07
Name Pipe Insulation Parallel Piping Compact Distribution Compact Distribution
Type Recirculation Control Shower Drain Water Heat
Recovery
DHW Sys 1 - 1/1 Not Required Not Required Not Required None Not Required Not Required
423-P010041798A-000-000-0000000-0000 03/10/2023 15:44 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 3 Calculation Date/Time:2023-03-10T08:50:33-08:00 (Page 13 of 16)
Calculation Description:Title 24 Analysis Input File Name:22112UP3.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-03-10 08:52:33
SPACE CONDITIONING SYSTEMS
01 02 03 04 05 06 07 08 09
Name System Type Heating Unit Name Heating Equipment
Count Cooling Unit Name Cooling Equipment
Count Fan Name Distribution Name Required
Thermostat Type
HVAC1
Heating and
cooling system
other
Heating
Component 1 1 Cooling
Component 1 1 HVAC Fan 1 Air Distribution
System 1 Setback
HVAC - HEATING UNIT TYPES
01 02 03 04
Name System Type Number of Units Heating Efficiency
Heating Component 1 Central gas furnace 1 AFUE-95
HVAC - COOLING UNIT TYPES
01 02 03 04 05 06 07 08 09
Name System Type Number of Units Efficiency Metric Efficiency
EER/EER2/CEER
Efficiency
SEER/SEER2 Zonally Controlled Mulit-speed
Compressor HERS Verification
Cooling
Component 1 Central split AC 1 EER/SEER 12.5 15 Zonally Controlled Single Speed
Cooling
Component
1-hers-cool
HVAC COOLING - HERS VERIFICATION
01 02 03 04 05 06
Name Verified Airflow Airflow Target Verified EER/EER2 Verified SEERSEER2 Verified Refrigerant Charge
Cooling Component
1-hers-cool Required 275 Required Not Required Required
423-P010041798A-000-000-0000000-0000 03/10/2023 15:44 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 3 Calculation Date/Time:2023-03-10T08:50:33-08:00 (Page 14 of 16)
Calculation Description:Title 24 Analysis Input File Name:22112UP3.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-03-10 08:52:33
HVAC - DISTRIBUTION SYSTEMS
01 02 03 04 05 06 07 08 09 10 11 12
Name Type Design Type
Duct Ins. R-value Duct Location Surface Area
Bypass Duct Duct Leakage HERS Verification
Supply Return Supply Return Supply Return
Air Distribution
System 1
Unconditioned
attic Non-Verified R-6 R-6 Attic Attic n/a n/a No Bypass Duct Air Distribution
System 1-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01 02 03 04 05 06 07 08 09
Name Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design Buried Ducts Deeply Buried
Ducts
Low-leakage Air
Handler
Low Leakage
Ducts Entirely in
Conditioned
Space
Air Distribution
System 1-hers-dist Yes 5.0 Not Required Not Required Not Required Credit not taken Required No
HVAC - FAN SYSTEMS
01 02 03 04
Name Type Fan Power (Watts/CFM)Name
HVAC Fan 1 HVAC Fan 0.45 HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01 02 03
Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM)
HVAC Fan 1-hers-fan Required 0.45
423-P010041798A-000-000-0000000-0000 03/10/2023 15:44 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 3 Calculation Date/Time:2023-03-10T08:50:33-08:00 (Page 15 of 16)
Calculation Description:Title 24 Analysis Input File Name:22112UP3.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-03-10 08:52:33
INDOOR AIR QUALITY (IAQ) FANS
01 02 03 04 05 06 07 08 09
Dwelling Unit Airflow (CFM)Fan Efficacy
(W/CFM)IAQ Fan Type
Includes
Heat/Energy
Recovery?
IAQ Recovery
Effectiveness - SRE
Includes Fault
Indicator Display?HERS Verification Status
SFam IAQVentRpt 125 0.35 Exhaust No n/a No Yes
423-P010041798A-000-000-0000000-0000 03/10/2023 15:44 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 3 Calculation Date/Time:2023-03-10T08:50:33-08:00 (Page 16 of 16)
Calculation Description:Title 24 Analysis Input File Name:22112UP3.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-03-10 08:52:33
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:Documentation Author Signature:
Company:Signature Date:
Address:CEA/ HERS Certification Identification (If applicable):
City/State/Zip:Phone:
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:Responsible Designer Signature:
Company:Date Signed:
Address:License:
City/State/Zip:Phone:
Rudy Sains
Heritage Energy Group, LLC 03/10/2023
470 Wald
Irvine, CA 92618 949-584-1052
Kevin Paul
Pulte Group, Inc. - Southern CA 03/10/2023
27101 Puerta Real, Suite 300
Mission Viejo, CA 92691 (949) 330-8591
423-P010041798A-000-000-0000000-0000 03/10/2023 15:44 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of
this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.