Loading...
HomeMy WebLinkAboutIE94414A - CA45527-A-03_100%_CD__20250307_v1.pdf-APPROVED PLAN NG [�I ION APPROVAL Riverside County Fire partment A1 _ ® _ Office of the Fire M a, -Mobile. . . GrQ�IL d/%7Cli By: Chris Adams 3257 EAST GUASTI ROAD,SUITE 200 DATE: 08/26/2025 7:40:58 AM FIRE SAFETY SPEC I LIST O,CA 91764 I J 08/26/2025 11:47: T-MOBILE SITE I G. L- <<�// The approval of plans and specif ti not permit the violation,deletion,o i s faulty installation of any require e t o �A or any Local Ordinances.Constr c i s all PROJECT. L600 remain accessible and exposed f lIr inspecalun purposes until approved by the F r Depal°M§ COAST DR,SUITE 200 MESA,CA 92626 - 5 SITE CONFIGURATION: 67E5A998C 12 PORT 3 RADIOS 4HCS PERMIT# gLDG 2025 02 SITE NAME: IE94414A M SQUTAR �j 1387 CALLE AVANZADO SBA SITE ID: CA45527 A 03 SAN CLEMENTE CA 92673(949)391-6824 SITE TYPE: MONOPINE DRAWN BY: DGM SITE ADDRESS: 16401 LAKESHORE DR, LAKE ELSINORE, CA 92530 City ° ° E°—Ake Elsonarb E DING DIVISION SITE INFORMATION VICINITY MAP PROJECT DESCRIPTION DRAWING INDEX Per t - - If PROPERTY OWNER. MACHADO STORAGE LLC ��� T-MOBILE PROPOSES TO MODIFY AN EXISTING WIRELESS INSTALLATION.THE SCOPE WILL CONSIST OF SHEET NO: SHEET TITLE 16401 LAKESHORE DR, THE FOLLOWING: LAKE ELSINORE,CA 92503 U.S.Postal Service y�. REMOVE (1) EXISTING T-MOBILE PTS 8003 CABINET T-1 TITLE SHEET APPLICANT: 7-MOBILE WEST CORPORATION Circle K� (a�P;%' `� REREMOVE OVE (1) EX IST,NGT-MOBILENGT-MOBLE BB 6301 CABINET GN-1 GENERAL NOTES A-1 SITE PLAN&ENLARGED SITE PLAN B 03/07/2025 100%CD'S FOR SUBMITTAL EM ADDRESS: 3257 EAST GUASTI ROAD,SUITE 200 Convenience store h` �� y. REMOVE (1) EXISTING T-MOBILE PSU 4813 ONTARIO,CA 91764 �c A-2 EQUIPMENT LAYOUT A 01/27/2025 90%CD's FOR REVIEW I EM d INSTALL (3) NEW ERICSSON RRUS 4480 B71+B85 A_3 ANTENNA LAYOUT SIT INSTALL (1) NEW T-MOBILE RP 6651 WITHIN EXISTING EQUIPMENT CABINET REV DA SC IPTI BY LAT/LONG TYPE: NAD-83 0 SI A-4 ELEVATIONS LATITUDE: 33.68847000 O U-Haul Eazycuts A-5 ELEVATIONS LONGITUDE: -117.37461000 LE Advanced Techs Neighborhood Deal r barbering stufios D-1 DETAILS ZONING JURISDICTION: CITY OF LAKE ELSINORE Machado Storage O 5 ,,cy G-1 GROUNDING DETAILS �pF ESS/pN ZONING CLASSIFICATION: C1 COMMERCIAL P. CURRENT USE: UNMANNED TELECOMMUNICATIONS FACILITY �'&� RIVERA SMOG CHECK Q ASSESSOR'S PARCEL NO.: 379-250-045 C0 0 oy cy PROPOSED USE: UNMANNED TELECOMMUNICATIONS FACILITY Q Drug $Rite Aid Q (d� Psho GENERAL NOTES LU 50 7 TYPE OF CONSTRUCTION: V-B Knobby Shop South(Dirt °off OCCUPANCY GROUP: B Bike Rentals... ey THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION.HANDICAPPED ACCESS �Y Stepping Stones 0 REQUIREMENTS ARE NOT REQUIRED IN ACCORDANCE WITH THE 2022 CALIFORNIA BUILDING CODE.A Preschool and Child Care TECHNICIAN WILL VISIT THE SITE AS REQUIRED FOR ROUTINE MAINTENANCE.THE PROJECT WILL NOT EXP.DATE:06/30/2025 +/� RESULT IN ANY SIGNIFICANT DISTURBANCE OR EFFECT ON DRAINAGE;NO SANITARY SEWER SERVICE, J` C'v1�. �\ map 'S4> POTABLE WATER,OR TRASH DISPOSAL IS REQUIRED AND NO COMMERCIAL SIGNAGE IS NEW. 9TFOF CA�\�O PROJECTTEAM 4 0 e N DATE SIGNED 03/07/2025 40" n adm dui J� �'T IS AVIOLATION OF LAW FORANY PERSON,UNLESSTHEYCLIENT REPRESENTATIVE: CONSTRUCTION MANAGER: �O 0y ENGINEERINGARE ACTING UNDER THE DIRECTION OF A LICENSED °n C C,„ 4 T-MOBILE WEST CORPORATION T-MOBILE WEST CORPORATION S� PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. 3257 EAST GUASTI ROAD,SUITE 200 �W E 3257 EAST GUASTI ROAD,SUITE 200 ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ONTARIO,CA 91764 ONTARIO,CA 91764 .Y© pry .Q ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS T-MOBILE PROJECT MANAGER: RF ENGINEER: Pwkview�: S ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. T-MOBILE SITE ID:IE94414A T-MOBILE WEST CORPORATION T-MOBILE WEST CORPORATION beiae brov" 2022 CALIFORNIA BUILDING CODE SITE NAME:IE94414A 3257 EAST GUASTI ROAD,SUITE 200 3257 EAST GUASTI ROAD,SUITE 200 CITY/COUNTY ORDINANCES ADDRESS:16401 Lakeshore Dr ONTARIO,CA 91764 ONTARIO,CA 91764 BUILDING OFFICIALS&CODE ADMINISTRATORS(BOCA) APPROVALS LAKE ELSINORE,CA 92530 CONTACT:BRIGITTE FOLIA CO M SQUARED WIRELESS: DRIVING DIRECTIONS 2022 MECHANICAL CODE EMAIL:BRIGITTE.BYERS@T-MOBILE.COM 1387 CALLE AVANZADO 2022 FIRE CODE MONOPINE PROJECT MANAGER: SAN CLEMENTE,CA 92673 2022 PLUMBING CODE THE FOLLOWING PARTIES HEREBY APPROVE AND ACCEPT THESE DOCUMENTS&AUTHORIZE THE SUBCONTRACTOF SBA SITE ID:CA45527-A-03 JOY THACKER 2022 ELECTRICAL CODE TO PROCEED WITH THE CONSTRUCTION DESCRIBED HEREIN.ALL DOCUMENTS ARE SUBJECT TO REVIEW BY THE SITE DEVELOPMENT SPECIALIST II J LOCAL BUILDING CODE LOCAL BUILDING DEPARTMENT&MAY IMPOSE CHANGES OR MODIFICATIONS. SOUTH COAST DR,SUITE 200 r T-MOBILE RF ENGINEER: DATE: COSTA MESA,CA 959 92626 ■ • ■ SHEET TITLE Nr _ T-MOBILE OPERATIONS: DATE: DO NOT SCALE TITLE SHEET KT 1 7 N SITE ACQUISITION: DATE: "� •in DRAWINGS j,Jl CONSTRUCTION MANAGER: DATE: ilir SUBCONTRACTOR SHALL VERIFY ALL PLANS, EXISTING • PROPERTY OWNER: DATE: SHEET NUMBER CONSTRUCTION DRAWING ❑' •�• ' DIMENSIONS&FIELD CONDITIONS ON THE JOB SITE&SHALL call Toll Free IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY 1-80c0-422-4133 ZONING: DATE: DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE 2WNrkln Da.=11ceYEaTDIg T- ANDROID&IPHONE USERS:POINT CAMERA AT THE OR CODE TO RECEIVE RESPONSIBLE FOR SAME. oeRE ouY+o se IF USING 11"X17"PLOT..DRAWINGS WILL BE HALF SCALE DIRECTIONS FROM T-MOBILE WEST CORPORATION,ONTARIO,CA 91764 or soUTH.R.uuruRHu PROJECT MANAGER: DATE: ERAL CONSTRUCTION NOTE CTRICAL 1. FOR THE PURPOSE OF CO SSTRUCTION DRAWINGS,THE FOLLOWING DEFINITIONS SHALL APPLY: 1. ELECTRICAL CONTRACTOR SHALL SUPPLY APPROVAL P ANP�MI�TAlO 1RJ1/!RI�E6T1M//lL DIVISION 1.S. COMPRESSION CONNECTIONS(2),2 AWG BARE TINNED SOLID COPPER CONDU R TO GENERAL CONTRACTOR-GENERAL CONTRACTOR CONSTRUCTION SHALL BE IN ACCORDANCE W/DRAWINGS AND ANY/ALL APPLICABLE SPECIFICATIONS. IF ANY GROUNDING BAR.ROUTE CONDUCTORS TO BURIED GROUNDING RING AND PR 'ib> 'i�le County Fire partment SUBCONTRACTOR-CONTRACTOR(CONSTRUCTION) PROBLEMS ARE ENCOUNTERED BY COMPLYING WITH THESE REQUIREMENTS, CONTRACTOR SHALL NOTIFY EXOTHERMIC WELD. OWNER-T-MOBILE 'CONSTRUCTION MANAGER'AS Soo � �F�yyb D R,s/yy�'.�/n,��P '�•y��r7,7���,SHALL NOT 2. EC SHALL USE PERMANENT MARKER TO DRAW THE LINES BETWEEN EACH SECTION ANp(� 1,� 2. ALL SITE WORK SHALL BE COMPLETED AS INDICATED ON THE DRAWINGS AND T-MOBILE PROJECT SPECIFICATIONS. PROCEED WITH THAT PORTION OF Vd0��E"CCSW6 ��-'^^-"-`""' ^""'�^^^^'^T"" LABEL EACH SECTION("P","A","N","I")WITH 1"HIGH LETTERS. t/��I CP. Of the P. Fire M I -Mobile. . . le 3. GENERAL CONTRACTOR AND SUBCONTRACTOR SHALL VISIT THE SITE AND SHALL FAMILIARIZE HIMSELF WITH ALL ACTIONS TO BE TAKEN. 3. ALL HARDWARE 18-8 STAINLESS STEEL,INCLUDING LOCK WASHERS,COAT ALL SURFACES CONDITIONS AFFECTING THE PROPOSED WORK AND SHALL MAKE PROVISIONS. GENERAL CONTRACTOR AND 2. ELECTRICAL CONTRACTOR SHALL VISIT THE JOB SITE AMIL RIZQE� ELF W NY/ALL CO IONS WITH AN ANTI-OXIDANT COMPOUND BEFORE MATING.ALL HARDWARE SHALL BE STAINLESS SUBCONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING HIMSELF WITH ALL CONTRACT DOCUMENTS,FIELD AFFECTING ELECTRICAL AND COMMUNICATION INSTALLATI( P E STEEL 3/8INCH DIAMETER OR LARGER. 32Jr7 EAST GUASTI ROAD,SUITE 200 CONDITIONS, DIMENSIONS,AND CONFIRMING THAT THE WORK MAY BE ACCOMPLISHED AS SHOWN PRIOR TO (E)CONDITIONS OF ELECTRICAL EQUIP.,LIGHT FIXTURES,E A A E A H I EM,^A L 4. FOR GROUND BOND TO STEEL ONLY:INSERT A CADMIUM FLAT WASHER BETW w0hris Adams PROCEEDING WITH CONSTRUCTION. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE VERIFIED BY THE CONTRACTOR,PRIOR TO THE SUB",.,:*;"""",..e-ems+" =ri:L�fRC�B STEEL,COAT ALL SURFACES WITH AN ANTI-OXIDANT COMPOUND BEFORE MATIN O,CA 917E4 ARCHITECT/ENGINEER PRIOR TO THE COMMENCEMENT OF WORK. WILL IN NO WAY RELIEVE CONTRACTOR J.�F FIR08/ �QKPf Q'�SAFV:FaI .:QQI18LFff WORKING 5. NUT&WASHER SHALL BE PLACED ON THE FRONT SIDE OF THE GROUNDING BAR AND BOLTED FIRE SAFETY SPEC I LIST 4. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, SYSTEM. 'DAM C �JO/LVILIJLJ I 4' aJ /"� ON THE BACK SIDE. REGULATIONS,AND ORDINANCES.GENERAL CONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY 3. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST EDITION OF THE NEC AND ALL CODES AND 6. NUMBER OF GROUNDING BARS MAY VARY DEPENDING ON THE TYPE OF TOWER,ANTENNA 08/26/2025 11:48: WITH ALL LT-MOBILE, ORDINANCES, RULES, REGULATIONS,AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY LOCAL ORDINANCES OF THE LOCAL P LOCATION,AND CONNECTION ORIENTATION.PROVIDE AS REQUIRED. REGARDING THE PERFORMANCE OF WORK. BUT NOT BE LIMITED TO: 7. WHEN THE SCOPE OF WORK REQUIRES THE ADDITION OF A GROUNDING BAR AN( j®V8I of plans and specif' ti 5. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS C-NATIONAL FIRE CODES TOWER,THE SUBCONTRACTOR SHALL OBTAIN APPROVAL FROM THE TOWER O Re fileas AND LOCAL JURISDICTIONAL CODES,ORDINANCES,AND APPLICABLE REGULATIONS. A. UL-UNDERWRITERS LABORATORIES APPROVED MOUNTING THE GROUNDING BAR TO THE TOWER. +[] mit the violation,deletion,o I s 6. UNLESS NOTED OTHERWISE,THE WORK SHALL INCLUDE FURNISHING MATERIALS,EQUIPMENT,APPURTENANCES, B. NEC-NATIONAL ELECTRICAL CODE 8. ALL ELECTRICAL AND GROUNDING AT THE CELL SITE SHALL COMPLY WITH TH TCSN AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. C. NEMA-NATIONAL ELECTRICAL MANUFACTURERS ASSOC. ELECTRICAL CODE(NEC),NATIONAL FIRE PROTECTION ASSOCIATION(NFPA) Q*instal lation of any require e t o 113 A 7. PLANS ARE NOT TO BE SCALED.THESE PLANS ARE INTENDED TO BE A DIAGRAMMATIC OUTLINE ONLY UNLESS D. OSHA-OCCUPATIONAL SAFETY AND HEALTH ACT EDITION),AND MANUFACTURER. Oran Local Ordinances.Constr I S all OTHERWISE NOTED.DIMENSIONS SHOWN ARE TO FINISH SURFACES UNLESS OTHERWISE NOTED.SPACING BETWEEN E. SBC-STANDARD BUILDING CODE y EQUIPMENT IS THE MINIMUM REQUIRED CLEARANCE.THEREFORE,IT IS CRITICAL TO FIELD VERIFY DIMENSIONS, 4. DO NOT SCALE ELECTRICAL DRAWINGS,REFER TO SITE PLANS AND ELEVATIONS FOR EXACT LOCATIONS OF ALL SITE WORK&DRAINAGE remain accessible and exposed f Ins 1 SHOULD THERE BE ANY QUESTIONS REGARDING THE CONTRACT DOCUMENTS,THE SUBCONTRACTOR SHALL BE EQUIPMENT,AND CONFIRM WITH'CONSTRUCTION MANAGER'ANY SIZES AND LOCATIONS WHEN NEEDED. COAST DR,SUITE 200 RESPONSIBLE FOR OBTAINING A CLARIFICATION FROM THE ARCHITECT/ENGINEER PRIOR TO PROCEEDING WITH THE 5. (E)SERVICES:CONTRACTOR SHALL NOT INTERRUPT(E)SERVICES WITHOUT WRITTEN PERMISSION OF THE OWNER. PART 1-GENERAL purposes until approved by the F r DepalnS1 MESA,CA 92626 WORK. DETAILS ARE INTENDED TO SHOWN DESIGN INTENT. MODIFICATIONS MAY BE REQUIRED TO SUIT JOB 6. CONTRACTOR SHALL PAY FOR ANY/ALL PERMITS,FEES,INSPECTIONS AND TESTING.CONTRACTOR IS TO OBTAIN DIMENSIONS OR CONDITIONS AND SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF WORK AND PREPARED BY PERMITS AND APPROVED SUBMITTALS PRIOR TO THE WORK BEGINNING OR ORDERING EQUIPMENT. CLEARING,GRUBBING,STRIPPING,EROSION CONTROL,SURVEY,LAYOUT,SUBGRAFa TIC#ANC[3 1 L.J V D202502 5 THE ARCHITECT/ENGINEER PRIOR TO PROCEEDING WITH WORK 7. THE TERM "PROVIDE" USED IN CONSTRUCTION DOCUMENTS AND SPECIFICATIONS, INDICATES THAT THE REQUIRED TO COMPLETE THE PROPOSED WORK SHOWN IN THESE PLANS. oO Lam_LJ lJ 8. THE SUBCONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S CONTRACTOR SHALL FURNISH AND INSTALL. RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. 8. CONTRACTOR SHALL CONFIRM WITH LOCAL UTILITY COMPANY ANY/ALL REQUIREMENTS SUCH AS THE:LUG SIZE 1.1 REFERENCES: 9. IF THE SPECIFIED EQUIPMENT CANNOT BE INSTALLED AS SHOWN ON THESE DRAWINGS.THE SUBCONTRACTOR RESTRICTIONS, CONDUIT ENTRY, SIZE OF TRANSFORMERS, SCHEDULED DOWNTIME FOR THE OWNERS' A. DOT(STATE DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS FOR HIGHWAY CONSTRUCTION-CURRENT SHALL PROPOSE AN ALTERNATIVE SPACE FOR APPROVAL BY THE ARCHITECT/ENGINEER PRIOR TO PROCEEDING. CONFIRMATION, ETC... ANY/ALL CONFLICTS SHALL BE BROUGHT TO THE ATTENTION OF THE CONSTRUCTION EDITION). 10. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY OF WORK AREA,ADJACENT AREAS AND BUILDING MANAGER,PRIOR TO BEGINNING ANY WORK. B. ASTM(AMERICAN SOCIETY FOR TESTING AND MATERIALS). OCCUPANTS THAT ARE LIKELY TO BE AFFECTED BY THE WORK UNDER THIS CONTRACT.WORK SHALL CONFORM TO 9. MINIMUM WIRE SIZE SHALL BE#12 AWG, NOT INCLUDING CONTROL WIRING, UNLESS NOTED OTHERWISE.ALL C. OSHA(OCCUPATION SAFETY AND HEALTH ADMINISTRATION). ALL OSHA REQUIREMENTS AND THE LOCAL JURISDICTION. CONDUCTORS SHALL BE COPPER WITH THWN INSULATION. M S QU A R L•,J 11. 10. OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS,CAST ALLOY WITH THREADED HUBS IN WET/DAMP GENERAL CONTRACTOR SHALL COORDINATE WORK AND SCHEDULE WORK ACTIVITIES WITH OTHER DISCIPLINES. TESTING: 1NSPECTION AND T 12. ERECTION SHALL BE DONE IN A WORKMANLIKE MANNER BY COMPETENT EXPERIENCED WORKMAN IN ACCORDANCE LOCATIONS AND SPECIAL ENCLOSURES FOR OTHER CLASSIFIED AREAS. 1.2 FIELD TESTING EARTHWORK COMPACTION AND CONCRETE CYLINDERS SHALL BE PERFORMED BY SUBCONTRACTORS W I R E L E S S WITH APPLICABLE CODES AND THE BEST ACCEPTED PRACTICE.ALL MEMBERS SHALL BE LAID PLUMB AND TRUE AS 11. IT IS NOT THE INTENT OF THESE PLANS TO SHOW EVERY MINOR DETAIL OF THE CONSTRUCTION.CONTRACTOR IS INDEPENDENT TESTING LAB.THIS WORK TO BE COORDINATED BY THE SUBCONTRACTOR. INDICATED ON THE DRAWINGS. EXPECTED TO FURNISH AND INSTALL ALL ITEMS FOR A COMPLETE ELECTRICAL SYSTEM AND PROVIDE ALL B. ALL WORK SHALL TESTING INSPECTED AND RELEASED BY THE GENERAL CONTRACTOR WHO SHALL CARRY OUT THE GENERAL 1 3 8 7 C A L L E A V A N Z A D O 13. SEAL PENETRATIONS THROUGH FIRE RATED AREAS WITH UL LISTED MATERIALS APPROVED BY LOCAL JURISDICTION. REQUIREMENTS FOR THE EQUIPMENT TO BE PLACED IN PROPER WORKING ORDER. INSPECTION OF THE WORK WITH SPECIFIC CONCERN TO PROPER PERFORMANCE OF THE WORK AS SPECIFIED AND/OR SAN CLEMENTE CA 92673(949)391-6824 SUBCONTRACTOR SHALL KEEP AREA CLEAN,HAZARD FREE,AND DISPOSE OF ALL DEBRIS. 12. ELECTRICAL SYSTEM SHALL BE AS COMPLETELY AND EFFECTIVELY GROUNDED,AS REQUIRED BY SPECIFICATIONS, CALLED FOR ON THE DRAWINGS.IT IS THE SUBCONTRACTOR'S RESPONSIBILITY TO REQUEST TIMELY INSPECTIONS PRIOR 14. WORK PREVIOUSLY COMPLETED IS REPRESENTED BY LIGHT SHADED LINES AND NOTES.THE SCOPE OF WORK FOR SET FORTH BY T-MOBILE. TO PROCEEDING WITH FURTHER WORK THAT WOULD MAKE PARTS OF WORK INACCESSIBLE OR DIFFICULT TO INSPECT. THIS PROJECT IS REPRESENTED BY DARK SHADED LINES AND NOTES.SUBCONTRACTOR SHALL NOTIFY THE GENERAL 13. ALL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR IN A FIRST CLASS,WORKMANLIKE CONTRACTOR OF ANY (E) CONDITIONS THAT DEVIATE FROM THE DRAWINGS PRIOR TO THE BEGINNING MANNER.THE COMPLETED SYSTEM SHALL BE FULLY OPERATIVE AND SUBJECT TO REGULATORY INSPECTION AND 1.3 SITE MAINTENANCE AND PROTECTION: CONSTRUCTION, APPROVAL BY CONSTRUCTION MANAGER. A. PROVIDE ALL NECESSARY JOB SITE MAINTENANCE FROM COMMENCEMENT OF WORK UNTIL COMPLETION OF THE 15. SUBCONTRACTOR SHALL PROVIDE WRITTEN NOTICE TO THE CONSTRUCTION MANAGER 48 HOURS PRIOR TO 14. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH THE PROGRESS OF SUBCONTRACT. COMMENCEMENT OF WORK. CONSTRUCTION. B. AVOID DAMAGE TO THE SITE AND TO(E)FACILITIES,STRUCTURES,TREES,AND SHRUBS DESIGNATED TO REMAIN.TAKE 16. THE SUBCONTRACTOR SHALL PROTECT(E)IMPROVEMENTS,PAVEMENTS,CURBS,LANDSCAPING AND STRUCTURES. 15. CONTRACTOR SHALL GUARANTEE ANY/ALL MATERIALS AND WORK FREE FROM DEFECTS FOR A PERIOD OF NOT LESS PROTECTIVE MEASURES TO PREVENT(E)FACILITIES THAT ARE NOT DESIGNATED FOR REMOVAL FROM BEING DAMAGED ANY DAMAGED PART SHALL BE REPAIRED AT SUBCONTRACTOR'S EXPENSE TO THE SATISFACTION OF THE OWNER. THAN ONE YEAR FROM DATE OF ACCEPTANCE. BY THE WORK. 17. THE SUBCONTRACTOR SHALL CONTACT UTILITY LOCATING SERVICES PRIOR TO THE START OF CONSTRUCTION. 16. THE CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ANY ADDITIONAL CHARGE AND SHALL INCLUDE DRAWN BY: DGM 18. GENERAL CONTRACTOR SHALL COORDINATE AND MAINTAIN ACCESS FOR ALL TRADES AND SUBCONTRACTORS TO THE REPLACEMENT OR THE REPAIR OF ANY OTHER PHASE OF THE INSTALLATION,WHICH MAY HAVE BEEN C. KEEP SITE FREE OF ALL PONDING WATER. THE SITE AND/OR BUILDING. DAMAGED THEREIN. D. PROVIDE EROSION CONTROL MEASURES IN ACCORDANCE WITH STATE DOT AND EPA REQUIREMENTS. E. PROVIDE AND MAINTAIN ALL TEMPORARY FENCING,BARRICADES,WARNING SIGNALS AND SIMILAR DEVICES NECESSARY C C ED 19. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SECURITY OF THE SITE FOR THE DURATION OF 17. ADEQUATE AND REQUIRED LIABILITY INSURANCE SHALL BE PROVIDED FOR PROTECTION AGAINST PUBLIC LOSS AND CONSTRUCTION UNTIL JOB COMPLETION. ANY/ALL PROPERTY DAMAGE FOR THE DURATION OF WORK. TO PROTECT AGAINST THEFT FROM PROPERTY DURING THE ENTIRE PERIOD OF CONSTRUCTION.REMOVE ALL SUCH I}� Rson 20. THE GENERAL CONTRACTOR SHALL MAINTAIN IN GOOD CONDITION ONE COMPLETE SET OF PLANS WITH ALL 18. PROVIDE AND INSTALL CONDUIT,CONDUCTORS,PULL WIRES,BOXES,COVER PLATES AND DEVICES FOR ALL OUTLETS DEVICES UPON COMPLETION OF THE WORK. `Y REVISIONS,ADDENDA,AND CHANGE ORDERS ON THE PREMISES AT ALL TIMES. AS INDICATED. F. (E)UTILITIES:DO NOT INTERRUPT(E)UTILITIES SERVING FACILITIES OCCUPIED BY THE OWNER OR OTHERS,EXCEPT WHEN 21. THE GENERAL CONTRACTOR AND SUBCONTRACTOR SHALL PROVIDE PORTABLE FIRE EXTINGUISHERS WITH A RATING 19. DITCHING AND BACK FILL:CONTRACTOR SHALL PROVIDE FOR ALL UNDERGROUND INSTALLED CONDUIT AND/OR PERMITTED IN WRITING BY THE ENGINEER AND THEN ONLY AFTER ACCEPTABLE TEMPORARY UTILITY SERVICES HAVE OF NOT LESS THAN 2-A OT 2-A:10-B:C AND SHALL BE WITHIN 25 FEET OF TRAVEL DISTANCE TO ALL PORTIONS OF CABLES INCLUDING EXCAVATION AND BACKFILLING AND COMPACTION. REFER TO NOTES AND REQUIREMENTS BEEN PROVIDED. WHERE THE WORK IS BEING COMPLETED DURING CONSTRUCTION. 'EXCAVATION,AND BACKFILLING. . PROVIDE A MINIMUM 48-HOUR NOTICE TO THE ENGINEER AND RECEIVE WRITTEN NOTICE TO PROCEED BEFORE Perm t - - 22. ALL(E)ACTIVE SEWER,WATER,GAS,ELECTRIC,AND OTHER UTILITIES SHALL BE PROTECTED AT ALL TIMES,AND 20. MATERIALS,PRODUCTS AND EQUIPMENT,INCLUDING ALL COMPONENTS THEREOF,SHALL BE(N)AND SHALL APPEAR INTERRUPTING ANY UTILITY SERVICE. WHERE REQUIRED FOR THE PROPER EXECUTION OF THE WORK,SHALL BE RELOCATED AS DIRECTED BY THE ON THE LIST OF U.L.APPROVED ITEMS AND SHALL MEET OR EXCEED THE REQUIREMENTS OF THE NEC,NEMA AND ARCHITECT/ENGINEER.EXTREME CAUTION SHOULD BE USED BY THE SUBCONTRACTOR WHEN EXCAVATING OR IECE. DRILLING PIERS AROUND OR NEAR UTILITIES. SUBCONTRACTOR SHALL PROVIDE SAFETY TRAINING FOR THE 21. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS OR MANUFACTURES CATALOG INFORMATION OF ANY/ALL LIGHTING ENVIRONMENTAL NOTES WORKING CREW.THIS SHALL INCLUDE BUT NOT BE LIMITED TO A)FALL PROTECTION,B)CONFINED SPACE,C) FIXTURES,SWITCHES AND ALL OTHER ELECTRICAL ITEMS FOR APPROVAL BY THE CONSTRUCTION MANAGER PRIOR 1, ALL WORK PERFORMED SHALL BE DONE IN ACCORDANCE WITH ISSUED PERMITS.THE CONTRACTOR SHALL BE ELECTRICAL SAFETY,D)TRENCHING&EXCAVATION. TO INSTALLATION. RESPONSIBLE FOR PAYMENT OF FINES AND PROPER CLEAN UP FOR AREAS IN VIOLATION. 23. ALL(E)INACTIVE SEWER,WATER,GAS,ELECTRIC,AND OTHER UTILITIES,WHICH INTERFERE WITH THE EXECUTION OF 22. ANY CUTTING OR PATCHING DEEMED NECESSARY FOR ELECTRICAL WORK IS THE ELECTRICAL CONTRACTORS 2. CONTRACTOR AND/OR DEVELOPER SHALL BE RESPONSIBLE FOR CONSTRUCTION AND MAINTENANCE OF EROSION AND Date: THE WORK,SHALL BE REMOVED,CAPPED,PLUGGED OR OTHERWISE DISCONNECTED AT POINTS WHICH WILL NOT RESPONSIBILITY AND SHALL BE INCLUDED IN THE COST FOR WORK AND PERFORMED TO THE SATISFACTION OF THE SEDIMENTATION CONTROLS DURING CONSTRUCTION FOR PROTECTION OF ADJACENT PROPERTIES,ROADWAYS AND B 03/07/2025 100%CD'S FOR SUBMITTAL EM INTERFERE WITH THE EXECUTION OF THE WORK,AS DIRECTED BY THE RESPONSIBLE ARCHITECT/ENGINEER,AND 'CONSTRUCTION MANAGER UPON FINAL ACCEPTANCE. WATERWAYS AND SHALL BE MAINTAINED IN PLACE THROUGH FINAL JURISDICTIONAL INSPECTION&RELEASE OF SITE. SUBJECT TO THE APPROVAL OF THE OWNER AND/OR LOCAL UTILITIES. 23. THE ELECTRICAL CONTRACTOR SHALL LABEL ALL PANELS WITH ONLY TYPEWRITTEN DIRECTORIES.ALL ELECTRICAL 3. CONTRACTOR SHALL INSTALL/CONSTRUCT ALL NECESSARY SEDIMENT/SILT CONTROL FENCING AND PROTECTIVE A 01/27/2025 90%CD's FOR REVIEW EM 24. THE AREAS OF THE OWNER'S PROPERTY DISTURBED BY THE WORK AND NOT COVERED BY THE TOWER,EQUIPMENT WIRING SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. MEASURES WITHIN THE LIMITS OF SITE DISTURBANCE PRIOR TO CONSTRUCTION. OR DRIVEWAY,SHALL BE GRADED TO A UNIFORM SLOPE,AND STABILIZED TO PREVENT EROSION. 24. DISCONNECT SWITCHES SHALL BE H.P.RATED HEAVY-DUTY,QUICK-MAKE AND QUICK-BREAK ENCLOSURES,AS RE A SC IPTI BY 25. SUBCONTRACTOR SHALL MINIMIZE DISTURBANCE TO THE(E)SITE DURING CONSTRUCTION.EROSION CONTROL REQUIRED BY EXPOSURE TYPE. 4. NO SEDIMENT SHALL R ALLOWED S EXIT THE PROPERTY.THE CONTRACTOR IS RESPONSIBLE FOR TAKING ADEQUATE ///��� MEASURES,IF REQUIRED DURING CONSTRUCTION,SHALL BE IN CONFORMANCE WITH THE FEDERAL AND LOCAL 25. ALL CONNECTIONS SHALL BE MADE WITH A PROTECTIVE COATING OF AN ANTI-OXIDE COMPOUND SUCH AS"NO-OXIDE MEASURES FOR CONTROLLING EROSION.ADDITIONAL SEDIMENT CONTROL FENCING MAY BE REQUIRED IN ANY AREAS / SUBJECT TO EROSION. ,/••�` JURISDICTION FOR EROSION AND SEDIMENT CONTROL. A"BY DEARBORNE CHEMICAL CO.COAT ALL WIRE SURFACES BEFORE CONNECTING.EXPOSED COPPER SURFACES, 5. CONTRACTOR SHALL BE RESPONSIBLE FOR DAILY INSPECTIONS AND ANY REPAIRS OF ALL SEDIMENT 26. NO FILL OR EMBANKMENT MATERIAL SHALL BE PLACED ON FROZEN GROUNDING.FROZEN MATERIALS,SNOW OR ICE INCLUDING GROUND BARS,SHALL BE TREATED-NO SUBSTITUTIONS. CONTROL MEASURES INCLUDING SEDIMENT REMOVAL AS NECESSARY. SHALL NOT BE PLACED IN ANY FILL OR EMBANKMENT. 26. RACEWAYS:CONDUIT SHALL BE SCHEDULE 40 PVC MEETING OR EXCEEDING NEMA TC2-1990.CONTRACTOR SHALL 6. CLEARING OF VEGETATION AND TREE REMOVAL SHALL BE ONLY AS PERMITTED AND BE HELD TO A 27. THE SUBGRADE SHALL BE BROUGHT TO A SMOOTH UNIFORM GRADE AND COMPACTED TO 95 PERCENT STANDARD PLUG AND CAP EACH END OF SPARE AND EMPTY CONDUITS AND PROVIDE TWO SEPARATE PULL STRINGS-200 LBS MINIMUM.ONLY TREES NECESSARY FOR CONSTRUCTION OF THE FACILITIES SHALL BE REMOVED. Q F ESS1 PROCTOR DENSITY UNDER PAVEMENT AND STRUCTURES AND 80 PERCENT STANDARD PROCTOR DENSITY IN OPEN TEST POLYETHYLENE CORD.ALL CONDUIT BENDS SHALL BE A MINIMUM OF 2 FT.RADIUS.RGS CONDUITS WHEN 7. SEEDING AND MULCHING AND/OR SODDING OF THE SITE WILL BE ACCOMPLISHED AS SOON AS Q{�0 A LSO'✓.q SPACE.ALL TRENCHES IN PUBLIC RIGHT OF WAY SHALL BE BACKFILLED WITH FLOWABLE FILL OR OTHER MATERIAL SPECIFIED,SHALL MEET UL-6 FOR GALVANIZED STEEL.ALL FITTINGS SHALL BE SUITABLE FOR USE WITH THREADED POSSIBLE AFTER COMPLETION OF THE PROJECT FACILITIES AFFECTING LAND DISTURBANCE. rr,,O F1.W�7 PRE-APPROVED BY THE LOCAL JURISDICTION. RIGID CONDUIT.COAT ALL THREADS WITH'BRITE ZINC'OR'GOLD GALV'. V 28. ALL NECESSARY RUBBISH,STUMPS,DEBRIS,STICKS,STONES,AND OTHER REFUSE SHALL BE REMOVED FROM THE 27. SUPPORT OF ALL ELECTRICAL WORK SHALL BE AS REQUIRED BY NEC. 8. CONTRACTOR SHALL PROVIDE ALL EROSION AND SEDIMENTATION CONTROL MEASURES AS REQUIRED ,/- BY LOCAL,COUNTY AND STATE CODES AND ORDINANCES TO PROTECT EMBANKMENTS FROM SOIL SITE AND DISPOSED OF IN A LAWFUL MANNER. 28. CONDUCTORS:CONTRACTOR SHALL USE 98%CONDUCTIVITY COPPER WITH TYPE THWN INSULATION,800 VOLT, LOSS AND TO PREVENT ACCUMULATION OF SOIL AND SILT IN STREAMS AND DRAINAGE PATHS 29. ALL BROCHURES,OPERATING AND MAINTENANCE MANUALS,CATALOGS,SHOP DRAWINGS,AND OTHER DOCUMENTS COLOR CODED.USE SOLID CONDUCTORS FOR WIRE UP TO AND INCLUDING NO.8 AWG.USE STRANDED CONDUCTORS LEAVING THE CONSTRUCTION AREA.THIS MAY INCLUDE SUCH MEASURES AS SILT FENCES,STRAW y v R1 SHALL BE TURNED OVER TO THE GENERAL CONTRACTOR AT COMPLETION OF CONSTRUCTION AND PRIOR TO FOR WIRE ABOVE NO.8 AWG. LV 50 PAYMENT. 29. CONNECTORS FOR POWER CONDUCTORS: CONTRACTOR SHALL USE PRESSURE TYPE INSULATED TWIST-ON BALE SEDIMENT BARRIERS,AND CHECK DAMS. W 30. SUBCONTRACTOR SHALL SUBMIT A COMPLETE SET OF AS-BUILT REDLINES TO THE GENERAL CONTRACTOR UPON CONNECTORS FOR NO.10 AWG AND SMALLER.USE SOLDERLESS MECHANICAL TERMINAL LUGS FOR NO.8 AWG AND 9. RIP RAP OF SIZES INDICATED SHALL CONSIST OF CLEAN,HARD,SOUND,DURABLE,UNIFORM IN COMPLETION OF PROJECT AND PRIOR 70 FINAL PAYMENT. LARGER. QUALITY STONE FREE OF ANY DETRIMENTAL QUANTITY OF SOFT,FRIABLE,THIN,ELONGATED OR 31. SUBCONTRACTOR SHALL LEAVE PREMISES IN A CLEAN CONDITION. 30. SERVICE:240/120V,SINGLE PHASE,3 WIRE CONNECTION AVAILABLE FROM UTILITY COMPANY.OWNER OR OWNERS LAMINATED PIECES,DISINTEGRATED MATERIAL,ORGANIC MATTER,OIL,ALKALI,OR OTHER DELETERIOUS SUBSTANCES 32. THE PROPOSED FACILITY WILL BE UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SEWER SERVICE,AND IS AGENT WILL APPLY FOR POWER. EXP.DATE:06/30/20NOT FOR 11 25 33. OCCUPANCY ISNLIMITED TO PERIODIC TAT(NO AP ACCESS MA MAINTENANCE AIND INSPECTION,APPROXIMATELY 2 TIMES PER MONTH,BY 31 DRAWINGSE SERVICE:CONTRACTOR SHALL PROVIDE EMPTY CONDUITS WITH PULL STRINGS AS INDICATED ON CIvil- T-MOBILE TECHNICIANS. 32. ELECTRICAL AND TELCO RACEWAYS TO BE BURIED A MINIMUM OF Z DEPTH. OF CA1-�F� 34. NO OUTDOOR STORAGE OR SOLID WASTE CONTAINERS ARE PROPOSED. 33. CONTRACTOR SHALL PLACE TWO LENGTHS OF WARNING TAPE AT A DEPTH OF 12"BELOW GROUND AND DIRECTLY 35. ALL MATERIAL SHALL BE FURNISHED AND WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST REVISION ABOVE ELECTRICAL AND TELCO SERVICE CONDUITS. CAUTIONS TAPE TO READ"CAUTION BURIED ELECTRIC" OR T-MOBILE GROUNDING STANDARD"TECHNICAL SPECIFICATION FOR CONSTRUCTION OF GSM/GPRS WIRELESS SITES" "BURIED TELECOMM". DATE SIGNED:03/07/2025 AND"TECHNICAL SPECIFICATION FOR FACILITY GROUNDING".IN CASE OF A CONFLICT BETWEEN THE CONSTRUCTION 34. ALL BOLTS SHALL BE STAINLESS STEEL SPECIFICATION AND THE DRAWINGS,THE DRAWINGS SHALL GOVERN. [7p7l VIOLATION OF L FOR ANV PERSON,UNLESS THEY 36. SUBCONTRACTORSSHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTIONS REQUIRED FOR AREACTINGU AWNDERTHE DIRECTION OF A LICENSED CONSTRUCTION.IF SUBCONTRACTOR CANNOT OBTAIN A PERMIT,THEY MUST NOTIFY THE GENERAL CONTRACTOR ROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. IMMEDIATELY. 37. SUBCONTRACTOR SHALL REMOVE ALL TRASH AND DEBRIS FROM THE SITE ON A DAILY BASIS. 38. INFORMATION SHOWN ON THESE DRAWINGS WAS OBTAINED FROM SITE VISITS AND/OR DRAWINGS PROVIDED BY THE T-MOBILE SITE ID:IE94414A SITE OWNER.CONTRACTORS SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCIES PRIOR TO ORDERING MATERIAL OR PROCEEDING WITH CONSTRUCTION. .SITE NAME:IE94414A 39. NO WHITE STROBIC LIGHTS ARE PERMITTED. LIGHTING IF REQUIRED, WILL MEET FAA STANDARDS AND ADDRESS:16401 Lakeshore Dr REQUIREMENTS. LAKE ELSINORE,CA 92530 40. ALL COAXIAL CABLE INSTALLATIONS TO FOLLOW MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS. MONOPINE 41. NO NOISE,SMOKE,DUST,OR VIBRATIONS WILL RESULT FROM THIS FACILITY.(DISREGARD THIS NOTE IF THIS SITE HAS AGENERATOR) SBA SITE ID:CA45527-A-03 42. NO ADDITIONAL PARKING TO BE PROPOSED.(E)ACCESS AND PARKING TO REMAIN,UNLESS NOTED OTHERWISE. 43. NO LANDSCAPING IS PROPOSED AT THIS SITE,UNLESS NOTED OTHERWISE. SHEET TITLE GENIERAL MOTES SHEET NUMBER GN-1 CITY OF LAK= ELSINORF NOTES: DISCLAIMER: PLANNING D VISION APPROVAL 1. THE WIRELESS COMMUNICATION FACILITY THIS SET OF DRAWINGS WAS PREPARED Riverside County Fire partment COMPLIES WITH FEDERAL STANDARDS FOR UTILIZING INFORMATION OBTAINED FROM PUBLIC RADIO FREQUENCY IN ACCORDANCE WITH THE DOCUMENTS MADE AVAILABLE ON JURISDICTION PERMIT - - Office of the Fire M I TELECOMMUNICATION ACT OF 1996 AND WEBSITE. M SQUARED WIRELESS CANNOT ' -Ivlobile' ' ' SUBSEQUENT AMENDMENTS AND ANY OTHER GUARANTEE THE ACCURACY OF THE DATA AND REQUIREMENTS IMPOSED BY STATE OR INFORMATION DEPICTED AND HEREBY �j4 i/��/ FEDERAL REGULATORY AGENCIES. EXPRESSLY DISCLAIMS ANY RESPONSIBILITY ��llffJJ t/Vi FOR THE TRUTH, VALIDITY, INVALIDITY, By: Chris Adams ADDED OR REMOVED AS PART OF THE NEW AND INFORMATION.THE PARCEL LINES ON MAPS 3257 EAST GUASTI ROAD,SUITE 200 2. NO EXISTING PARKING STALLS ARE BEING ACCURACY, INACCURACY OF ANY SAID DATA 0,CA 91764 INSTALLATION. ARE FOR ILLUSTRATION PURPOSES ONLY AND FIRE SAFETY SPEC I DATE: 08/26/2025 7:40:5 AM LIST ARE NOT INTENDED TO BE USED AS A SURVEY 08/26/2025 11:48: 3. THESE DRAWINGS WERE PRODUCED WITHOUT PRODUCT.USER ACCEPTS RESPONSIBILITY FOR THE BENEFIT OF A CURRENT LAND SURVEY.ALL THE UNAUTHORIZED USE OR TRANSMISSION OF PROPERTY LINES,EASEMENTS,SETBACK$,AND ANY SUCH DATA OR INFORMATION IN ITS ACTUAL The approval of plans and specif' ti EXISTING CONDITIONS ARE APPROXIMATE AND OR ALTERED FORM. AP P RO E D not permit the violation,deletion,O I s�p�,p SHALL BE VERIFIED PRIOR TO START OF `,, CONSTRUCTION. faulty Installation Of any require oft 0 or any Local Ordinances.Constr i s all L 1 remain accessible and exposed f inspection purposes until approved by the F r Depa cQAST OR,SUITE 200 +\ I MESA,CA 92626 PERMIT#- BLDG 2025 02 5 M SQUAR(Ew. WIRELESS �oe +\ /EXISTING \ / I BUILDING,TY +`+\ `A� I 1387 CALLE AVANZADO 0" ' I SAN CLEMENTE CA 92673(949)391-6824 I x- x-x-x-x-x-x-x-x- =ENLARGEDSITEPLAN, +\ i -x-x-x-x-x-x-x-x-x-x-x-x-x- DRAWN BY: DGM -- - -SEE REFERENCE: .., /, I - // +\ 1,2 EXISTING T-MOBILE I �EQUIPMENTI LAYNG I UT 2 C C ED I ��■■■■t■■ ■ i ANTENNA LAYOUT DIVISION Perm t - 2025-2150 _ - / ■ ■ - - _ N/�� �y� = / / / i' ' Date: -' Cal ■ TTAL EM B 03/07/2025 100%CD'S FOR SUBMI �Q'"/' 4i.O // // /, i ■ A 01/27/2025 90%CD'S FOR REVIEW EM '- - ' I' , ■ REV DA SC IPTI BY MENNEIRE _ _ ■ ■ _ = APN:379-250-045 I ■ ■ A�OFESS/ N N/ EXISTING A VV BUILDING,TYP. -M■ ■■■■■■■ 0 y4�v PJ'f, p�2Ctn I I � y Ll w507 \+ - O I DATE SIGNED:03/07/2025 IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY EXISTING SPRINT ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. EQUIPMENT AREA T-MOBILE SITE ID:IE94414A SITE NAME:IE94414A LU ADDRESS:16401 Lakeshore Dr z 1,z LAKE ELSINORE,CA 92530 : I A-5 MONOPINE �L } SBA SITE ID:CA45527-A-03 w 0- I APN:379-250-045 0 i SHEET TITLE D SITE PLAN& EXISTING TREE,TYP.---/ / N N ENLARGED SITE PLAN ' e GW v E E� SHEET NUMBER S 5 A-1 SITE PLAN 24"x36 SCALE: '" = 2°'-°" z 4' 1 ENLARGED SITE PLAN 24"x36 SCALE: 3/16" = 1'-0" 2' 4' S' 11"x17" SCALE: 1" = 40'-0" 11"x17" SCALE: 3/32" = 1'-0" ® n NOTE: �� 1 P MEWS 1 ION APPROVAL 1. DRAWINGS ARE BASED OF EXISTING ,.J DOCUMENTS,PLANS&PICTURES. DOCUMENTS,PLANS&PICTURES. Riverside County Fire E partment CONTRACTOR TO VERIFY FIELD CONTRACTOR TO VERIFY FIELD CONDITIONS PRIOR TO CONSTRUCTION. P E R M I OI I ° - Office of the Fire M I 2. NEW CABLE ROUTING TO FOLLOW • ■ -Ivoblle EXISTING.ROUTING ON PLANS SHOWN EXISTING.ROUTING ON PLANS SHOWN GENERICALLY.CONTRACTOR TO VERIFY ENE CALLY. NTRACT VERIFY EXISTING BEST ROUTE TO FOLLOW. ES T 3. EQUIPMENT ON MONOPOLE NOT SHOWN 3. O N By: Chris Adams 3257 EAST GUASTI ROAD,SUITE 200 FOR CLARITY. I QWIAWO,CA 91764 DATE: 8 5 7: :5 FIRE SAFETY SPECIALIST 08/26/2025 11:48: APPROVED The approval of plans and specif' ti not permit the violation,deletion,o i s faulty installation of any require e t o A or any Local Ordinances.Constr i %11113 remain accessible and exposed f ins .v�Ia_q purposes until approved by the F r Depa L[LIL c EST OR,SUITE 200 MESA,CA 92626 PERMIT#- BLDG 2025 02 5 EXISTING T-MOBILE EQUIPMENT/LEASE AREA EXISTING T-MOBILE EQUIPMENT/LEASE AREA M S Q U A RA EXISTING H-VAC,TVP. EXISTING H-VAC,TYP. / WIRELESS"' 1387 CALLE AVANZADO EXISTING WOODEN FENCE EXISTING WOODEN FENCE SAN CLEMENTE CA 92673(949)391-6824 EXISTING T-MOBILE FEEDLINES TO REMAIN: (,)6X12 HCS,OAWG 30M < (3)6/24 4AWG 30M HARDEN BOTH 6160 AND 8160 CABINETS WITH PUCK LOCK ON DOORS EXISTING T-MOBILE lI EXISTING T-MOBILE B160 EXISTING T-MOBILE EXISTING T-MOBILE 3160 DRAWN BY: DGM ICE BRIDGE i BATTERY CABINET ICE BRIDGE BATTERY CABINET 4p-, I II I I C C ED EXISTING T-MBILEI Iti EXISTING T-MOBILE 6160 CIt ,----- 6160 CABINET �-' CABINET WITHE `Y__ FOLLOWING NEW 3�o o ii EOUIPMENT INSTALLED D-1 ¢ o ¢ o ii WITHIN: ¢ o / 6" iI �� (1)RP 8681 ¢ Perm tXISTING T-MOBILE " LU TS 8003 CABINET z o z O BE REMOVEDn ouo EXISTING Il v °' w EXISTING EXISTING T-MOBILE �, w MONOPINE BASE --------J JI FEEDLINES TO REMAIN: w MONOPINE BASE (1)6X12HCS10AWG30M Date: (3)6/24 4AWG 30M B 03/07/2025 100%CD'S FOR SUBMITTAL EM 2 E A 01/27/2025 90%CD'S FOR REVIEW EM F F z z REV DA SC IPTI BY W W EXISTING T-MOBILE RBS 6201 EXISTING EXISTING T-MOBILE CABINET TO BE EXISTING EXISTING T-MOBILE OF CSS/0A' BUILDING,TYP. EQUIPMENTPAD I I I BUILDING,TYP. EQUIPMENTPAD P A WL ��2 EXISTING T-MOBILE INSIDE (` t4 �7 EXISTING T-MOBILE EQUIPMENT TO BE REMOVED; EXISTING T-MOBILE (V 0 UTILITY H-FRAME (1)BB 6630 UTILITY H-FRAME O 2 ?•m (1)DUW y V (1)PSU 481813 w 50 7 � EXP.DATE:06/30/2025 cli 9TEOF C � DATE SIGNED:03/07/2025 IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. T-MOBILE SITE ID:IE94414A SITE NAME:IE94414A ADDRESS:16401 Lakeshore Dr LAKE ELSINORE,CA 92530 MONOPINE SBA SITE ID:CA45527-A-03 SHEET TITLE EQUIPMENT LAYOUT N N eEQ eEa SHEET NUMBER ® S S EXISTING EQUIPMENT LAYOUT 11 x37" SCALE: 3/16"= 1 NEW EQUIPMENT LAYOUT 11"x36" SCALE: 3/1 = 2 A-2 11"x17" SCALE: 3/16" = 1'-0" 12 RAD CABLE P LCABLE NOTES TO CONTRACTOR: APPRO ANTENNA MAKE CENTER AZIMUTH RADIO MODEL CABLE TYPE LENGTH HCS AWN N A CENTER AZIMUTH RADIOMCUeL CABLE TYPE LENGTH HCS 1 v, Tt P Ijy,Flr'� partment 4 VERIF�YfME +F�NF��O�RI�S�RECSPIP1 ESI blL17Yl L X ERICSSON AIR6449 B41 33.1"X20.5"X8.3" ST-0" 100° - (4)2F SM - P E R M IF0m__M-CC 5"X8.3" 54'-6" 100° - (4)2F SM - CONDITIOf $ '�1 Q� H ejA�15.1 o (4)SUREFLEX ' Moblle a m DISCREPANCIES ARE FOUND,THE CONTRACTOR M M M M M M w COMMSCOPE FFV4-65B-R3-V7 71.9"X25.1"X9.2" 53'-0" 100° RRUS 4424 825 (8)SUREFLEX 310' N O PE F 5B-R3- 1.9"X25A"X9 53'-0" 100° RRUS 4424 B25 (8)SUREFLEX 110, �oISRESPONSIBLE FOR CONTACTING THE CARRIER, RRUS 4415 B66A (8)2F SM RRUS 4415 B66A (8)2F SM _ ARCHITECT/ENGINEER,AND ANY OTHERS LISTED _ RRUS 4480 B71+885 vi c7T;1 P�Q,1,� T ffiN TACTS PROVIDED.ERICSSON AIR6449841 33.1"X20.5"X8.3" 53'-0" 210° - (4)2F SM - a O 3 RA '4 3257 EAST GUASTI ROAD,SUITE 200 O m _ (4)2F SM =a 2. TO T-MOBILE'S MOST w COMMSCOPE FFV4-658-R3-Vi 71.9"X25.1"X9.2" 53'-0" 21p^ RRUS 4424 B25 (8)SUREFLEX f10' 0 (4)SUREFLEX PRIOR TO CONSTRUC r1KITADIO,CA 91764 w RRUS4415B66A (8)2FSM - �� DATE. 8 'X9.2" 53'-0" 210° RRUS 4424 B25 (8)SUREFLEX i10' Z 3. CABLE LENGTHS WERE N�E SAFETY[�SOJ�., I LIST O Urn F 4�5 3' 1. RRUS 4415 B66A - O Z JA�gL�LSI 0: ERICSSON AIR6449 B41 33.1"X20.5"X8.3" 53'-0" 310° - (4)2F SM - n RRUS 4480 B71+B85 (8)2F SM O VISUAL INSPECTION E O w w U U CONTRACTOR TO VERIFY ACTUAL LENGTH V RRUS 4424 B25 (8)SUREFLEX 310' C 3 .3" 54'-6" 310° - (4)2F SM �� �fi69�if3tFV9Fl1 �nd s�eC f tCs$a y COMMSCOPE FFV4E5B-R3-V7 71.9"X25.1"X9.2" 53'-0" 310° RRUS 4415 B66A (8)2F SM - v v O (4)SUREFLEX w w 4. CON RAC-TPF , VE IFV P FIT AyE RRus4424B2sgi�rEn��ie vlolatlon, eleUo COMMSCOPE FFV4b5B-R3-V7 71.9"X25.1"X9.2" 53'-0" 310° RRUS 4415 B66A (8)gU2FESIL�EX t1D 5. FpA1441aSgL���AESIGgIsR.S�DL4L�NR, e RRUS 4480 B71+685 O A�tlJ' `AYthFI�'3�CZS o C4►-`/8RIF71'L@astOodirm ce ?ollanSt ir)el�'�rngyar`Lccessible and exposed f iv� 5. PINALr�e51GNIAN7ALVSf50ANDApP'kbVACe F r Depar[flr i l MESA,CA 26 6E zoo PROVIDED BY OTHERS.CONTRACTOR TO VERIFY MOUNT ANALYSIS: 1 GAMS`0 5 BY:T TES DAED:01/09/25 NOTE: 1. (E)ANTENNA AZIMUTHS ARE ESTIMATED AND M S Q U A R ��J ARE TO BE VERIFIED BY RF. WIRELESS 1387 CALLE AVANZADO SAN CLEMENTE CA 92673(949)391-6824 DRAWN BY: DGM EXISTING ANTENNA & EQUIPMENT SCHEDULE 3 NEW ANTENNA & EQUIPMENT SCHEDULE 4 C C ED NOTE: NOTE: E DING, DIVISION 1. NEW&EXISTING T-MOBILE EQUIPMENT TO BE PAINTED 1. NEW&EXISTING T-MOBILE EQUIPMENT TO BE PAINTED Perm t AND TEXTURED TO MATCH EXISTING TOWER. AND TEXTURED TO MATCH EXISTING TOWER. - 2025-2150-- 2. EXISTING OTHER CARRIER ANTENNAS&EQUIPMENT 2. EXISTING OTHER CARRIER ANTENNAS&EQUIPMENT NOT SHOWN FOR CLARITY. NOT SHOWN FOR CLARITY. 3. EXISTING MONOPINE BRANCHES NOT SHOWN FOR 3. EXISTING MONOPINE BRANCHES NOT SHOWN FOR CLARITY. CLARITY. Date: ------- B 03/07/2025 100%CD'SFORSUBMITTAL EM -f - NEW T-MOBILE RRUS 4480671+885 A 01/27/2025 90%CD'S FOR REVIEW EM 'O, •�,, MOUNTED ON PIPE MOUNT; S S (1 PER SECTOR,3 TOTAL) D REV, SC IPTI BY T P OAR@SiO° EXISTING T-MOBILE ERICSSON AIR6449 OOR��iod DA EXISTING T-MOBILE ERICSSON AIR6449 B41 PANEL ANTENNA ON PIPE MOUNT; ,c B41 PANEL ANTENNA ON PIPE MOUNT; (1 PER SECTOR,3 TOTAL) y (1 PER SECTOR,3 TOTAL) Q�pF GSS/Oiyq A.WHT Fy y o� 0y c2 EXISTING MONOPINE EXISTING MONOPINE Vi r�T1 W 50 7 p --- cc_ A"SECTOR CQ?f00° �100^ O O ^ EXP.DATE:O6/`30I2025`� 9T. F CA��F� EXISTING T-MOBILE RRUS 4415 B66A MOUNTED EXISTING T-MOBILE RRUS 4415 B66A MOUNTED DATE SIGNED:03/07/2025 ON PIPE MOUNT;(1 PER SECTOR,3 TOTAL) ON PIPE MOUNT;(1 PER SECTOR,3 TOTAL) IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. EXISTING T-MOBILE COMMSCOPE Sy, EXISTING T-MOBILE COMMSCOPE T-MOBILE SITE ID: 4A FFV4-65B-R3-V1 PANEL ANTENNA ON FFV4-65B-R3-V1 PANEL ANTENNA ON SITE NAME:IE94414A 14A PIPE MOUNT;(1 PER SECTOR,3 TOTAL) � PIPE MOUNT;(1 PER SECTOR,3 TOTAL) ADDRESS:16401 Lakeshore Dr LAKE ELSINORE,CA 92530 Et7ST7NG ebpST/aG ebp MONOPINE MQLNTF EXISTING T-MOBILE RRUS 4424 B25 MOUNTED MQLNTF EXISTING T-MOBILE RRUS 4424 B25 MOUNTED SBA SITE ID:CA45527-A-03 qOF ryp , ' ON PIPE MOUNT;(1 PER SECTOR,3 TOTAL) qOF _ ON PIPE MOUNT;(1 PER SECTOR,3 TOTAL) �R SHEET TITLE N N ANTENNA LAYOUT m m -Qw E Gw�EC SHEET t\IUMBER S S H p _3 EXISTING ANTENNA PLAN 24"x36 SCALE: '/ " = 1'-0" 1 2 41 24"x36 SCALE: 1/ " = 1'-0" 2' 4' 11"x17" SCALE: 1/44" = 1'-O' NEW ANTENNA PLAN 11"x17" SCALE: 1/44" 2 7 PL R I E . �V�S�ON APPROVAL Riverside County Fire partment PERM11 # BLDG-2025-02150 Office of the Fire M 3,T- -Mobile. ' • © By: Chris Adams 3257 EAST GUASTI ROAD,SUITE 200 O,CA 91764 DATE: 8/26/2025 7:40:59 AM FIRE SAFETY SPEC I LIST 08/26/2025 11:48:C 1 KA APPROVED The approval of plans and specif ti Re fileas not permit the violation,deletion,o i s' EXISTING VERIZON PANEL ANTENNAS EXI ING VE IZ PANE E AS aunty Ins�a�latlor4"d#�r�y require e t c I A TOP OFEXISTING MONOPINE TOP OFEXISTING MONOPINE or any Local Ordinances.Constr I s all 73'-0"A.G.L. .__..._ 75'-0"A.G.L. 75'-0"A.G.L. RAD CENTER_OF EXISTING VE_RIZON PANEL ANTENNAS_ _ __ RAD_CENTER_OF EXISTING VE_RIZON PANEL ANTENNAS_ _ __ �1 remain accessible and exposed f ins 1 L� 1 '' 73'-0"A.G.L. �-1COAST DR,SUITE 200 purposes until approved by the F r6,Deparftt� MESA,CA 92626 j PERMIT#- BLDG 2025 02 5 I I EXISTING SPRINT PANEL ANTENNAS I'I EXISTING SPRINT PANEL ANTENNAS 1A-D0"AE.NGT.LE.R OISGR A AI IU„IIaI . � 1AD CENTER OISGRNA A_ - - 6 _0"A.G.L. M S Q U A R E WIRELESS 1387 CALLE AVANZADO EXISTING T-MOBILE RRUS 4415 B66A MOUNTED EXISTING T-MOBILE RRUS 4415 B66A MOUNTED SAN CLEMENTE CA 92673(949)391-6824 ON PIPE MOUNT;(1 PER SECTOR,3 TOTAL) - ON PIPE MOUNT;(1 PER SECTOR,3 TOTAL) TOP OF EXISTING T-MOBILE PANEL ANTENNAS TOP OF EXISTING T-MOBILE PANEL ANTENNAS NEW T-MOBILE RRUS 4480 B71+B85 56'-0"A.G.L. 56'-0"A.G.L. MOUNTED ON PIPE MOUNT; IF RAD CENTER OF EXISTING T-MOBILE PANEL ANTENNAS- (1 PER SECTOR,3 TOTAL) RAD_CENTER_OF EXISTING T_MOBILE PANEL ANTENNAS 54'�"A.G.L. 53'-0"A.G.L. RAD CENTER OF EXISTING T-MOBILE PANEL ANTENNAS EXISTING T-MOBILE ERICSSON AIR6449 53'-0"A.G.L. 841 PANEL ANTENNA ON PIPE MOUNT; (1 PER SECTOR,3 TOTAL) DRAWN BY: DGM EXISTING T-MOBILE ERICSSON AIR6449 B41 PANEL ANTENNA ON PIPE MOUNT; EXISTING T-MOBILE RRUS 4424 B25 MOUNTED (1 PER SECTOR,3 TOTAL) ON PIPE MOUNT;(1 PER SECTOR,3 TOT C ED EXISTING T-MOBILE COMMSCOPE I t Cy EXISTING T-MOBILE RRUS 4424 B25 MOUNTED FFV4-65B-R3-Vi PANEL ANTENNA ON ON PIPE MOUNT;(1 PER SECTOR,3 TOTAL) PIPE MOUNT;(1 PER SECTOR,3 TOTAL) E DING DIVISION EXISTING T-MOBILE COMMSCOPE Perm t - - FFV4-65B-R3-V7 PANEL ANTENNA ON PIPE MOUNT;(1 PER SECTOR,3 TOTAL) I I I I I I ate: (a, - - B 0310712o25 100%CD'S FOR SUBMITTAL EM A 01/27/2025 90%CD'S FOR REVIEW EM RE A SC IPTI BY I I A I I Q�OF ESS11t) A.VVygRT F2 I I P EXISTING T-MOBILE FEEDLINES EXISTING -MOBILE TO REMAIN: FEEDLINES TO REMAIN: y .. ♦'O(1)6X12 H (1)6X12 HCS 10AWG 30M In (1) X7 (3)6/244AWGCS 30M10AWG 30M (3)6/244AWG 30M fe 50 7 .T1 I I EXISTING MONOPINE EXISTING MONOPINE EXP.DATE:06/30/2025 I I 9TFOF CAS-�F� DATE SIGNED:03/07/2025 IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. I I I I T-MOBILE SITE ID:IE94414A SITE NAME:IE94414A ADDRESS:16401 Lakeshore Dr LAKE ELSINORE,CA 92530 MONOPINE FINISH GRADE 1j FINISHGRADE SBA SITE ID:CA45527-A-03 ELEV.O'-0"REF. Y ELEV.O'-0"REF. SHEET TITLE EXISTING EQUIPMENT AREA EXISTING EQUIPMENT AREA ELEVATIONS SHEET NUMBER EXISTING NORTHEAST ELEVATION 11" 17" SCALE: 3/32" = �� � 1 NEW NORTHEAST ELEVATION 11 x17" SCALE: 3/32" = 1' 2 4 A-4 11"x17" SCALE: 3/32" = 1'-O" �� 11"x17" SCALE: 3/32" = 1'-0" PL R I E . �V�S�ON APPROVAL Riverside County Fire partment PERM11 # BLDG-2025-02150 Office of the Fire M 3,T- -Mobile. ' • © By: Chris Adams 3257 EAST GUASTI ROAD,SUITE 200 O,CA 91764 DATE: 8/26/2025 7:40:59 AM FIRE SAFETY SPEC I LIST 08/26/2025 11:48:C 1 KA APPROVED The approval of plans and specif ti Re fileas not permit the violation,deletion,o i s EXISTING VERIZON PANEL ANTENNAS E TI VERIZON Rq.ry L NTE au y If1slalla ISn&my require e t o$Tai1R A TOP A EXISTING MONOPINE __ �TOP OF EXISTING MONOPINE ______75' Pj -0"A.GL. 75'-0"AG.L. l or any Local Ordinances.Constr I RAD CENTER OF EXISTING VERIZON PANEL ANTENNAS RAD CENTER OF EXISTINGVERIZONPANELANTENNAS 1Hremain accessible and exposed f Ins 1 73'-o"A.G.L.- - - - - - - -- 73'-o°A.G.L.- - - - - - - -- purposes until approved by the F r Depa?FPrf�coAsr DR,SUITE 200 MESA,CA 92626 PERMIT#- BLDG 2025 02 5 D CENTER_OF EXISTING SPRINT PANEL ANTENNAS EXISTING SPRINT PANEL ANTENNAS EXISTING SPRINT PANEL ANTENNAS C/��\U A R RA _ _ _ RAD CENTER_OF EXISTING SPRINT PANEL ANTENNAS 1+ 63'-0"A.G.L. 63'-0"A.G.L. �f a WIRELESS 1387 CALLE AVANZADO EXISTING T-MOBILE RRUS 4415 B66A MOUNTED 4 EXISTING T-MOBILE RRUS 4415 B66A MOUNTED SAN CLEMENTE CA 92673(949)391-6824 ON PIPE MOUNT;(1 PER SECTOR,3 TOTAL) ON PIPE MOUNT;(1 PER SECTOR,3707AL) TOP OF EXISTING T-MOBILE PANEL ANTENNAS TOP OF EXISTING T-MOBILE PANEL ANTENNAS NEW T-MOBILE RRUS 4480 B71+B85 56'-0"A.G.L. 56'-0"A.G.L. MOUNTED ON PIPE MOUNT; RAD CENTER OF EXISTING T-MOBILE PANEL ANTENNAS- (1 PER SECTOR,3 TOTAL) RAD_CENTER_OF EXISTING T_MOBILE PANEL ANTENNAS 54'�"A.G.L. 53' RAD CENTER O_F EXISTI_NG 7-MO_BILE PANEL ANTENNAS EXISTING 7-MOBILE ERICSSON AIR6449 5ZN A.G.L. B41 PANEL ANTENNA ON PIPE MOUNT; (1 PER SECTOR,3TOTAL) DRAWN BY: DGM EXISTING T-MOBILE ON PIE MOUNT; EXISTING T-MOBILE RRUS 4424 B25 MOUNTED EB41XISTING PANEL ANTENNA ON PIPE MOUNT; ON PIPE MOUNT;(1 PER SECTOR,3 TOTAL) C C ED (1 PER SECTOR,3 TOTAL) /\^. \, EXISTING T-MOBILE COMMSCOPE �/I Y EXISTING T-MOBILE RRUS 4424 B25 MOUNTED FFV4-65B-R3-V7 PANEL ANTENNA ON I I I ON PIPE MOUNT;(1 PER SECTOR,3 TOTAL) PIPE MOUNT;(1 PER SECTOR,3 TOTAL) Pe t EXISTING T-MOBILE COMMSCOPE rm - - FFV4-65B-R3-Vi PANEL ANTENNA ON PIPE MOUNT;(1 PER SECTOR,3 TOTAL) I I I I Date: (a, 558-33-4 - B 0310712o25 100%CD'S FOR SUBMITTAL EM A 01/27/2025 90%CD'S FOR REVIEW EM RE A SC IPTI BY A I I I I I I Q�OF ESS11t) EXISTING 7-MOBILE FEEDLINEST TO REMAIN: y {T F1 E 6X1 NEC2 HCS 1 REMAIN:0AWG 30M EXISTING -MOBILE (1)6X12 HCS 10AWG 30M In (1) X7 (3)6124 4AWG 30M (3)6124 4AWG 30M w 50§ 7 .T1 fe EXISTING MONOPINE EXISTING MONOPINE EXP.DATE:06/30/2025 � CIVIC- CF CA�-�F DATE SIGNED:03/07/2025 IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. T-MOBILE SITE ID:IE94414A SITE NAME:IE94414A ADDRESS:16401 Lakeshore Dr LAKE ELSINORE,CA 92530 MONOPINE FINISH GRADE 1j FINISHGRADE SBA SITE ID:CA45527-A-03 ELEV.O'-0"REF. Y ELEV.O'-0"REF. SHEET TITLE EXISTING EQUIPMENT AREA EXISTING EQUIPMENT AREA ELEVATIONS SHEET NUMBER EXISTING SOUTHWEST ELEVATION 11" 17" SCALE: 3/32" = 1� �� � 1 NEW SOUTHWEST ELEVATION 11 x17" SCALE: 3/32" = 1' 2 4 A-5 11"x17" SCALE: 3/32" = 1'-0" �� 11"x17" SCALE: 3/32" = 1'-0" . 12 CITY OF LAKE El SINGIRE PLANNING DIVISION APPROVAL Riverside County Fire partment PERMIT # BLDG-2025-02150 MANUFACTURER: ERICSSON *INSTALL INSI eeKGf Iftq l{e Fire M 3, 1 MODEL NO.: RP 6651/). •INSTALLATION INTO EXISTING CABINET OR RACK -Mobile. . . DIMENSIONS(HxWxD): 1.75"x 19"x 13.85" REQUIRES NO SPECIAL INSPECTIONS. '&�,'/rli mw- © WEIGHT: 16.53 Les (T'p'// By: Chris Adams 3257 EAST GUASTI ROAD,SUITE 200 O,CA 91764 DATE: 08/26/2025 7:41:00 AM FIRE SAFETY SPEC I LIST INSTALL TO STANDARD FIF 08/26/2025 11:48: RACKICABINET WITH FIF RACK APPROVED BRACKET AND(4)10-32TITrt�Lapp val of plans and specif tl Re fileas SCREWS,(2)PER SIDE. not permi he violation,deletion,O I sJp� faulty instal tion of any require e t 0 �A or any Local rdinances.Constr i s all remain accessi le and exposed f ins i 1117 CAST o � ylrpOs 0 Oved by the r Depa?F MOE DR,SUITE 200 SA,CA 92626 Li 0 0 0 0 ®� 9 D 3 2025 02 5 FRONT VIEW M SQUAR •j WIRELESS 1387 CALLE AVANZADO NOT USED 24x36 SCALE: NTS g NOT USED 24x36" SCALE NTS 6 R P 6651 24x36 SCALE: NTS SAN CLEMENTE CA 92673(949)391-6824 11"x17 SCALE: NTS 11"x17 SCALE: NTS 11"x17 SCALE: NTS MANUFACTURER: ERICSSON [� MODEL NO.: RADIO 4480 B71+B85 DIMENSIONS: TOTAL WEIGHT H 21.8" DRAWN BY: DGM W 15.7" 84 LBS D 7.5" 1T`, C RRU W/SUNSHIELD m C I`Y C ED E DING, DIVISION TOP VIEW Per t - - w Date: B 03/07/2025 100%CD's FOR SUBMITTAL EM A 01/27/2025 90%CD'S FOR REVIEW EM SUNSHIELD RE A SC IPTI BY A Q�OF ESSIONQ FRONT VIEW SIDE VIEW y�vOPJ.A w/111 2y� i NOT USED 8 NOT USED 24"x36" SALE. NTS 5 RRU 4480 B71 +B85 24"x36" SCALE: NTS 11"x17" SCALE: NTS 11"x17" SCALE: NTS L 50 7 EXP.DATE,06/30/2025 Ci V t`y PIPE CLAMP 9TFOF CAS-CFO O MOUNTING BRACKET; PROVIDED BY MANUFACTURER DATE SIGNED:03/07/2025 IT IS VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARR E ACTINGUNDER THE DIRECTION LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. T-MOBILE SITE ID:IE94414A SITE NAME:IE94414A ADDRESS:16401 Lakeshore Dr LAKE ELSINORE,CA 92530 RRU MONOPINE PER PLAN SBA SITE ID:CA45527-A-03 MOUNTING PIPE PER PLAN SHEET TITLE DETAILS SHEET NUMBER D-1 NOT USED z1%17" SALE NTS 7 NOT USED ;1 x36 SCALE: NTS 4 RRU MOUNTING DETAIL 24"x36" SCALE: NTS 1 11"x17" SCALE: NTS CITY OF LAKE El SINORE WIRE SIZE BURNDY LUG BOLT SIZE ROVAL PLANNING DIVISION #6 GREEN INSULATED YA6C-2TC38 " S L ty Fire partment #2 SOLID TINNED YA3C-2TC38 3/8�� " - 6 NC SS 2 B LT PERMIT - - #2 STRANDED YA2C-2TC38 3/8" - 0 e Fire MIS ■Mobile■ ■ ■ #2/0 STRANDED YA26-2TC38 3/8" - 16 NO SS 2 BOLT o (TYPICALLI RIIA/� © #4/0 STRANDED YA28-2N 1/2" - 16 NO SS 2 BOLT y: Chns Adams 3257 EAST GUASTI ROAD,SUITE 200 �q�A/��+ O,CA 91764 NOTE: MINIMUM OF S/S NUT ANTENNA CABLE DA E. V,O/26/ 25 .41:fl�E�M BURNDY GROUND LUG W/ LONG BARREL HEAT SHRINK FIRE SAFETY SPEC I LIST 3 THREADS TO BE (TYP) (SEE CHART) (CLEAR) VISIBLE 08/26/2025 11:48: (TYP) NUT (TYP) 11 s/s sPUTOV E D LOCK WASHER (nP) he approval of plans and specif ti Re fileas WASHER 2 HOLE LONG (TYR) ABL of permit the violation,deletion,O I S BARREL TINNED �A4CONNECTOR SOLID COPLUG S/S FLAT faultryoinstallation of any require e t O � (TYP) WASHER WEATHERPROOFING KIT or abyDCcowal Ordinances.Constr I S all L1 (TYP) #6 STRANDED COPPER (SEE NOTE 3) cRouNDinain accessible and exposed f ins I cRourD WIRE ses until approved b the F r De a?tftj COAST DR,SUITE200 (GROUND TO GROUND BAR) CABLE GROUND KIT BOLT (SEFI�LiQi pp Y ID �qJ S�qy MESA,CA 92626 SEE NOTES 1 & 2 TIN COATED SOLID BURNDY TWO HOLE LUG (TYP) COPPER BUS BAR S/S FLAT W/ LONG BARREL PE RMIT#- B LD G 2025 02 5 WASHER NOTES: (SEE CHART) CHERRY INSULATOR (TYP) 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND BARE WIRE TO BE TREATED INSTALLED IF REQUIRED WITH NO-OX AT BOTH ENDS S/S BOLT WIRE DOWN TO GROUND BAR. (TYP) 2. GROUNDING KIT SHALL BE TYPE AND PART NUMBER AS SUPPLIED OR M SQUAR RECOMMENDED BY CABLE MANUFACTURER. (E3., 3. WEATHER PROOFING SHALL BE TWO-PART TAPE KIT, COLD SHRINK SHALL NOT BE NOTE:USED. STRANDED ALL GROUNDING LUGS ARE TO BEWIRELE (SEE CHART) INSTALLED PER MANUFACTURER'S 1 3 8 7 C A L L E A V A N Z A D O SPECIFICATIONS. ALL HARDWARE SAN CLEMENTE CA 92673(949)391-6824 BOLTS, NUTS, LOCK WASHERS SHALL BE STAINLESS STEEL. ALL HARDWARE ARE TO BE AS FOLLOWS: BOLT, FLAT ---- WASHER, GROUND BAR, GROUND LUG, FLAT WASHER AND NUT. LUG DETAIL 2107" SCALE: NTS 8 CABLE GROUND KIT CONNECTION 11 x16;; SCALE: NTS 6 MECHANICAL LUG CONNECTION 11"x17" SCALE: NTS 3 11"x17" SCALE: NTS DRAWN BY: DGM ® 3/8 TAMPER Il y RESISTANT BOLT STAINLESS STEEL BOLT (TYP) E DING, DIVISION (TYP) INSULATORS TO ANTENNA COAX STAINLESS STEEL SEE NOTE 2. COPPER/GALVANIZED GROUND BAR Perm t - - FLAT WASHER (TYR) 2-HOLE CRIMP/ (TYP) go r COMPRESSION WALL BRACKET ® O 0 0 0 00 O O O O O O O O O CONNECTOR (TYP) ® L O O 0 00000 0 0 0 0 000 ® o 0 0 0 000000000000o Q GROUND ® ® ® ® Date: ® ® #2 SOLID TINNED COPPER B 03/07/2025 100%CD'S FOR SUBMITTAL EM STAINLESS STEEL ® ® GROCONDNDTR RING OR O(2 NPR FOR TOWER/SHELTER A 01/27/2025 90%CD's FOR REVIEW EM FLAT WASHER ® ® ® (TMP)HOLE LONG BARREL COMPRESSION LUG BOTTOM GROUND BAR ONLY) RE A SC IPTI BY STAINLESS STEEL (TYP) ® UNIVERSAL COPPER BELLVILLE WASHER4 STAINLESS STEEL NUT ® GROUND BAR (4"x20") (TYP) (TYP) LOCK WASHER ® NOTES: SINGLE CONNECTOR AT GROUND BARS P/N M10 (TYP) 1 EXTERIOR ANTIOXIDANT JOINT COMPOUND TO BE USED ON ALL EXTERIOR CONNECTIONS.. GROUND BAR SHALL BE ROM STAINLESS STEEL BOLT COMPRESSION LUG 3. GROUND BAR SHALL BET ISOLATED F TOWER. MOUNT DIRECTLY TO TOWER STEEL (TOWER ONLY). ISOLATED SHELTER Q�QF ESSIONQ� NOTES: A•WHq�T�2 STAINLESS STEEL FLAT WASHER 1. DOWN LEAD (HOME RUN) CONDUCTORS ARE NOT TO BE INSTALLED ON CROWN CASTLE y 0 2 2 USA INC. TOWER, PER THE GROUNDING DOWN CONDUCTOR POLICY QAS-STD-10091. NO m MODIFICATION OR DRILLING To TOWER STEEL IS ALLOWED IN ANY FORM OR FASHION, LU 50 DRAGON TOOTH WASHER CAD-WELDING ON THE TOWER AND/OR IN THE AIR ARE NOT PERMITTED. (TYP) STEEL 2. OMIT INSULATOR WHEN MOUNTING TO TOWER STEEL OR PLATFORM STEEL USE INSULATORS WHEN ATTACHING TO BUILDING OR SHELTERS. EXP.DATE:06/30/2025 2-HOLE CRIMP/ STAINLESS STEEL GROUND BAR DETAIL 24"x36" SCALE: NTs 5 TOWER/SHELTER GROUND BAR DETAIL 24%36" SCALE: NTS 2 �qT C1��' o� COMPRESSION FLAT WASHER 11"x17" SCALE: NTS CONNECTOR (TYP) OF CA�-� STAINLESS STEEL STAINLESS STEEL NUT #6 MIN FROM ANTENNA BELLVILLE WASHER (TYP) CABLE GROUND KIT:�, DATE SIGNED:03/07/2025 (TYP) IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY C C AREACTING UNDER THE DIRECTION OF A LICENSED SINGLE CONNECTOR AT STEEL OBJECTS PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. TO ANTENNA COAX COPPER/GALVANIZED GROUND BAR STAINLESS STEEL STAINLESS STEEL T-MOBILE SITE ID:IE94414A SELF-DRILLING METAL SCREW FLAT WASHER SITE NAME:IE94414A (n,P) (TYP) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 o ADDRESS:16401 Lakeshore Dr GROUND BAR ON SHELTER. ICE 000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 o LAKE ELSINORE,CA 92530 2-HOLE CRIMP/ BRIDGE, OR ON ANTENNA TOWER MONOPINE COMPRESSION CONNECTOR OO�O OOOO O SBA SITE ID:CA45527-A-03 DRAGON TOOTH METALLIC OBJECT O O O O O O O O 0TWO HOLE WASHER O O COMPRESSION NLUG (TYP) SHEETTITLE (TYP) SINGLE CONNECTOR AT METALLIC/STEEL OBJECTS NOTES: GROUNDING DETAILS TWO HOLE LUG, OR GROUNDING SHALL BE 1. DOUBLING UP "OR STACKING" OF CONNECTIONS IS NOT PERMITTED. LIMINATED WHEN GROUND 2. EXTERIOR ANTIOXIDANT JOINT COMPOUND TO BE USED ON ALL EXTERIOR CONNECTIONS. EXOTHERMIC WELD TO BE E USED WITH #2 BARE BAR LI ELECTRICALLY BONDED 3. GROUND BAR SHALL NOT BE ISOLATED FROM TOWER. MOUNT DIRECTLY TO TOWER STEEL. IS CONDUCTOR WIRE TO TO METAL TOWER SHEET NUMBER BUILDING SERVICE GROUND OR GROUND RING -1 EXTERIOR CONNECTIONS DETAILS ;;::07" SCALE NTS 7 GROUNDWIRE INSTALLATION 11 24„%36;; SCALE: NTS 4 ANTENNA GROUND BAR DETAIL 1"x17" SCALE: NTS 1