Loading...
HomeMy WebLinkAboutCASINO DR 31736 (2) GENERAL NOTES: PIZZA H U T o w � o DI NOT SCALE DRAWINGS. USE TENANT � w z DIMENSIONS ONLY. IF A DISCREPANCY O � Cr U IS FOUND TO EXIST NOTIFY DESIGNER. Q W w D Cn OO DETAILS ARE INTENDED F SHOW ___ ___ __ IMPROVEMENT � 0' Q m `� �0 METHOD AND MANNER OF ACCOMPLISHING ax.as Z I-I—WORK, MINOR MODIFICATIONS MAY BE 80'-0 82'-5" 173'-11" m 0 Z m REQUIRED TO SUIT THE JOB LEGAL JURISDICTION: U 0 (� DIMENSIONS N JOB SITE ADDRESS: ^5 U O LJ OR CONDITIONS AND IS TO BE INCLUDED AS PART OF THE WORK. I LC) Q I DIMENSIONS ARE TAKEN FROM THE THE CITY OF LAKE ELSINORE NOW ENFORCES THE FACE OF THE ACTUAL STUD. VERIFY FOLLOWING EDITIONS OF THE MODEL CODES: ALL 2007 CALIFORNIA BUILDING CODE DIMENSIONS AND CONDITIONS AT THE 0 1 SITE I 2007 CALIFORNIA MECHANICAL CODE VERIFY FINDINGS, DIFFERENCES AND F— O M PRIOR STARTING ANY WORK. $I * 2007 CALIFORNIA PLUMBING CODE z N �' SUGGESTED MODIFICATIONS WITHLi DESIGNER ' I 2007 CALIFORNIA ELECTRICAL CODE N PRIOR TO BEGINNING PROJECT, Z I 2007 ENERGY EFFICIENCY STANDARDS W 0 I ALL NEW WORK SHALL COMPLY WITH THE D > O U INSULATION PER PLANS AND TITLE 24. ABOVE LISTED EDITIONS OF THESE MODEL CODES = r Z 0 LLJ - lY DOORS AND WINDOWS ARE TO BE 12 - 162.00' OCCUPANCY: A2, RESTAURANT N < FULLY WEATHER-STRIPPED AT ALL U p I JOINTS AND ALL — TYPE CONSTRUCTION: FIVE NON-RATED N cp Z F— IJ EXISTING BUILDING AREA: 2,783 SQ.FT. a- PENETRATIONS ARE TO BE CAULKED z AND SEALED. I ALL NEW GLAZING SHALL BE INSTALLED WITH CERTIFYING LABEL ATTACHED 4)SITE-----------� NORTH SCALEIPL20'-D" CONDITIONS ARE TOTAL AREA: 2,843 SQ.FT. z Y SHOWING 172.00' EXISTING w Q THE U-VALUE AND FINISTRATION. L _) COUNTY OF RIVERSIDE '1 EXISTING PARKING: NOT TO CHANGE PROVIDE ALL NECESSARY BACKING AND COMMUNITY HEALTH AGENCY PROJECT SUMMARY FRAMING FOR ALL MOUNTED ITEMS, DEPARTMENT OF ENVIRONMENTAL HEALTH LIGHTS, FANS, The p,opoeedcmetudonlequipment Al TITLE SHEET AND OTHER ITEMS THAT REQUIRE permanent approved Soap and towel intS a.ttecnedcppro sleet. A2 NEW FLOOR SAME. dispensers must be installed a AF,proved A3 DEMOLITION PLAN ALL NAILING SHALL BE INCOMPLIANCE all hand washing sinks. rnrsappovel olaut�nwim.a ' drAt Iew,ornroence,«omer reauktlon. M1 MECHANICAL PLAN WITH TABLE 23-11-B-1,COMMON NAILS M2 MECHANICAL PLAN ONLY. NOTIFY THE PLAN CHECKER 114 V01" ALL ELECTRICAL,PLUMBING,MECHANICAL.AND STRUCTURAL OFdNY CHANGF,S OR ALTERATKMTO REPAIRS AND INSTALLATIONS SHALL BE DONE UNDER PERMIT P1 PLUMBING PLAN ALL RECEPTACLE OUTLET LOCATIONS PLANS AS ORIGINALLY.APPROVED. FROM LA16 6 � P2 PLUMBING PLAN SHALL COMPLY WITH 2O07 CEC 210.52 o OE PT THIS APPROVAL DOES NOT INCLUDE THE THIS APPROVAL GRANTED 3Y THE DESIGN CRITERIA CONTRACTOR AND/OR SUBCONTRACTOR SUBSURFACE WASTEPTICE DISPOSAL SYSTEM INTERCEPTOR. COUNTY OF RIVERSIDE OR OTHER WASTE DISPOSAL SYSTEM.OBTAIN DEPARTMENT OF ENVIRONMENTAL HEALTH SHALL CAREFULLY STUDY AND CLEARANCE FROM APPPOPRIATEAGENCY ISVALID FORONE(1)YEAR FROM DATE OFAPPROVAL REVIS`fiONS FOR YOUR WASTE DISPOSAL SYSTEM. Q COMPARE ALL DRAWINGS, DATA, DIMENSIONS, LEGAL DESCRIPTION SPEC. & EXISTING SITE CONDITIONS CONTACT THE PLAN CHECKER FOR APRY7.6rHNA" Q BEFORE 8go%COMPIl,NM(H(HEMP E EQUTPMENrT IS ndAPPsrRT Ll PROCEEDING WITH ANY WORK, AND 1 d REPORT TO THE DESIGNER AT ONCE ANY ERROR, INCONSISTANCY AND/OR OMISSION HE/SHE MAY DISCOVER. Approval of these plans by the County of Riverside Department of Environmental Health,does not relieve the E REROUTE ALL EXISTING AC & WATER Engineer or Architect ofthe responsibility for the Enginee t PIPING AS REQUIRED. or Architectural design` ALL MEMBERS SHALL BE FRAMED, OWNER:� I I �� J.LARRY FUGATE PIZZA H U T ANCHORED, TIED & BRACED SO AS TO 208 S. MAZE RD (TENANT DEVELOP THE STRENGTH & RIGIDITY kb„I WICHITA, KANSAS 87209-31 1 0 wM1WM NECESSARY FOR THE PURPOSES II IMPROVEMENT) nIR FOR WHICH THEY ARE TO BE USED. 31736 CASINO DR POWELL AND ASSOCIATES DRATING LLC LAKE ELSINORE, CA 92530 ALL SPACING & EDGE AND END ! 9980 INDIANA AVE SUITE 3 DISTANCES SHALL BE SUCH AS TO RIVERSIDE, CA 92503 AVOID VICINITY MAP (951)352-3588 TITLE SHEET 8c SPLITTING OF THE WOOD. HOLES FOR ARCHITECT: NAILS, WHEN NECESSARY TO PREVENT SPLITTING, SHALL BE BORED OF A DIA. WILLARD C. MILLER 2323 CENTRAL AVE. SITE PLAN schedCall rledfivei(5)working days sinadv advance RIVERSIDE,Co 92506 SMALLER THAN THAT OF THE NAILS. scheduled five(5)working days in advance ALL OUTDOOR LIGHTING SHALL CONFORM TO THE GOVERNING CITY, ENGINEER: COUNTY, RSA REEDENGIN L. EKING INC.M.E. HpyA OR STATE AUTHORITY. 17643 BRIGHTMAN AVE Cy WILLARDC. a LAKE ELSINORE, CA 92530 MILLER PER SECTION 106.4.3 OF THE 2007 (951)816-7336 LC. 0 'CBC, THE APPROVAL AND/OR C PERMITTING OF THE OF CA 4-3o-�Q ° , Of Lj z O O O < CK � QWWmc) 00 0 J V 00 Uzmzm � LOWS i BEER BOX V D_ EW ADVANCE w t� FIA-O'EGETABLE RINK INK W/18° O STATION RAINBOARD!7 5PLA5 w H ICE EW MAKt 16"x20°BOWL CAI MACHINE 4 2APTOAWER TABLE W O O N - - � 0 OU I F= 1 °.-0� 2 2 o Z_ 2'-0 A 2 A ry - ELOCATED In W rr'-o• HAND Q •aS_ Q 2 — I SINK COOLER WALK-IN N G O O NEW WING GILE5 NEW 5.5.NEW Z ST.SAUCER VENTLE55 N WING 5T. HOOD(SEE TABLE FREEZER rr-� (n PREP. SPECS ~ W EXISTING DINING \�� 2 4 4 Q LLJ z gFREZ.WALK-IN W — 2"POWER 2 I — ♦— DATA ` INSTALL 5.5.ALONG BACK WALL EXISTING DINING \A r— BUFFET/SALAD BAR EXISTING HOOD 5HALLINr EOVER HANG COOKING RETARDER EQUIP.MIN.G"EA,SIDE I I EXISTING 5.5. 4'-0' --'-- 20 PROOFER COUNTY OF RLVERSWE 65°A.F. . S' COMMUNTry HEALTH AGENCY HIGH DEPARTMENT OF ENVIRONMENTAL HEALTH e xte^ S.S T 5T. Ne PANEL The proposed construmion/epulpment SHWASHER TON installation Is approved. 5HWA5H LOCATED See attached c rr ch n sheetELOC . to"xte^ r�.. SINK W/SPUSH Approved U 9Y REVISIONS 0PAN aeav I GUAren I EX15TING This approval not authorize the wo ahon of any °'-d' ELECTRICAL law,ordinance,or other repulation. Q EXISTING DINING OMPARTMENT b SERVICE l. ROUP METAL sr Q S SINK W/I 1, ^F.S. — 12°BA51N W/ BELOW oisnwn;i�roc DRATB Q DRAINBOARD ON EACH SIDE EXISTING MEN5 EX15TING 2 EX15TING SHELVING RE5TROOM WOMEN'5 W. RELOCATED RE5TROOM 117— M EXISTING HAND SINK RELOCATED ITu5(G PIZZA HU1 BTuS(GAS) (TENANT ALL BACK—UP DRY STORAGE UNITS SHALL IMPROVEMENT) BE A MINIMUM OF 3 TIERS HIGH AND A MINMUM OF 18" DEEP. LAKE CASINO DR LAKE ELSINORE, CA 92530 TOTAL LINEAR FOOTAGE OF EXISTING AND NEW SHELVING TOTALS 35' FLOOR/EQIP. PLAN FLOOR/EQIP. SCALE: 1 /4"= 1 '-0" PLAN A2 . z O O o < ryU < III omv� 00 Q J y 00 ozmz � t9 Uo U owe Ln � EXISTING CA5H OUT EXISTING MOP SINK TO BE RELOCATED F-.- ®®® IIN71sll LLJ In N RELOCATED w Q � BEER BOX EXISTING COOLER WALK-IN > O U HAND EX15T. U D15HWA5HER SINK O I z DINING SHALL BE DINING LLI RELOCATED O Q U SERVICE RELOCATE N O XI5TING AREA DRINK N � Z 5TATION 1 HAND AN NKD FREZ.WALK-IN J TO BE z LLJ I \ I RELOCATED Q I� W F45TING `EXISTING S z Y CUT TBL. ORDER DEMO/REMOVE w J ENTRY DINING WALL-(PATCH FIN.) oxxEXISTING BUFFET/5ALAD OVEN 6 BAR EX15TING KITCHEN HOOD RETARDER EXISTING 5.5. BAG-N-BOX HEATED SHALL BE PROOFER RELOCATED EX15TING ELECTRICAL SERVICE DINING REVISIONS 0 EX15TING MEWS EXISTING EXIST. RE5TKOOM WOMEN'S W'H' RE5TROOM EX15TING 5HELVING LAI,- SHALL BE RELOCATED PIZZA HU I DEMOLITION PLAN (TENANT SCALE: 1 /4"= 1 '-0" IMPROVEMENT) 31736 CASINO DR LAKE ELSINORE, CA 92530 DEMOLITION PLAN MECHANICAL GENERAL NOTES MECHANICAL LEGEND p SYMBOL ABBR. DESCRIPTION p I. CONTRACTOR SHALL CAREFULLY REVIEW THESE PUNS AND SPECIFICATIONS PRIOR TO BID. CONTRACTOR p SHALL ALSO REVEW PLANS AND SPECIFICATIONS OF OTHER RELATED TRADES(INCLUDING ARCHITECTURAL, I� SWS SIDEWALL SUPPLY GRILLE PLUMBING,STRUCTURAL,CIVIL,AND ELECTRICAL)PRIOR TO BID TO ENSURE AN ACCURATE UNDERSTANDING OF EXACT SCOPE OF WORK.FIELD INVESTIGATE EXISTING CONDITIONS PRIOR TO BID. CD CEILING SUPPLY DIFFUSER 2. EQUIPMENT INDICATED ON THIS DRAWING IS SHOWN IN APPROXIMATE POSRON(S). THE CONTRACTOR SHALL ® o poor - FIELD VERIFY ALL CONDITIONS INCLUDING EQUIPMENT LOCATIONS,AND STRUCTURAL MEMBERS PRIOR TO RAR RETURN AIR REGISTER INSTALLATION. NOTIFY THE CONSTRUCTION COORDINATOR OF ANY DISCREPANCIES OR CONFLICTS PRIOR TO v N L COMMENCING ANY WORK. DO NOT PROCEED WITHOUT CONSTRUCTION COORDINATOR APPROVAL FOR ANY a EAR EXHAUST AIR REGISTER u CHANGES IF REQUIRED. ® N o0 3. MECHANICAL CONTRACTOR SHALL OBTAIN AND PAY FOR NECESSARY PERMITS,FEES&LICENSES. 0 ® Lo RAO,SAD,EAD DUCT RISERS 4. ENTIRE INSTALLATION AND MATERIALS SHALL COMPLY WITH THE LATEST CBC,CMC AND APPLICABLE STATE ® ® AMENDMENTS, RAD,SAD,EAD DUCT DROPS 5. EQUIPMENT FURNISHED UNDER 7H15 CONTRACT SHALL HOVE A PERMANENT LIBEL CLEARLY INDICATING THE MID MANUAL VOLUME DAMPER MAINTENANCE TO BE PERFORMED TO MAINTAIN THE EQUIPMENT IN EFFICIENT OPERATING CONDITION.EQUIPMENT SUPPLIERS SHALL FURNISH THE FULL AND PARTIAL INPUT AND OUTPUT CAPACITIES TO ENABLE DETERMINATION I� (L) LINED DUCT .. aAiNc� OF COMPLIANCE WITH THE ENERGY CONSERVATION CODE. 4 -� 6. LINE VOLTAGE WIRING,ALL CONDUIT,DISCONNECT SWITCHES AND FINAL F.D. SMOKE FIRE DAMPER E n. CONNECTION BY ELECTRICAL CONTRACTOR. LOW VOLTAGE WIRING AND FINAL 3 --- CONNECTION BY MECHANICAL CONTRACTOR. at-- OSA OUTSIDE AIR(FRESH AIR) 'j a `GILES*MODEL FSH-2 VENTLESS FRYER HOOD: �3J VENTLESS H000 CONSISTS OF A BUILT-IN 18'CLEAR RECOMMENDED mN T-STAT THERMOSTAT W/UNIT NUMBER M m ANSUL FIRE SUPRESSION SYSTEM AND A /'RECIRC. BM FOR THE PURPOSE OF CLEARNESS AND LEGIBILITY,THE DRAWINGS ARE THREE STAGE AIR PURIFICATION SYSTEM / ESSENTIALLY DIAGRAMMATIC AND ALTHOUGH SIZES AND LOCATIONS OF EQUIPMENT IS A.F.F. ABOVE FINISHED FLOOR O —3Q DRAWN TO SCALE WHEREVER POSSIBLE,THE CONTRACTOR SHALL MAKE USE OF ALL U O S/S BAFFLE FILTER TRAPS GREASE PARTICLES —_- 2 DATA IN ALL OF THE CONTRACT DOCUMENTS AND VERIFY THIS INFORMATION BEFORE ODD BACKDRAFT DAMPER C5 M O2 PRECIPI4TOR FILTER COLLECTS DIRTY AIR PARTICLES ORDERING,FABRICATING OR INSTALLATION OF ANY MATERIALS. ___— —Q1 'u Lj-7E 30 DISP,CHARCOAL FILTER ELIMINATES ODOR MITCHEN H000 OBD OPPOSED RUDE DAMPER Q) Q. e (er ornms) INTAKE + T.G. TRANSFER GRILLE T F.C. FLEXIBLE CONNECTION Mf —20 GA.STAINLESS STEEL -47— O.L. DOOR LOUVER � SCOPE OF WORK `f ® e M BY MECHANICAL CONTRACTOR 1, INSTALL NEW VENTLESS FRYER HOOD i 2. TEST,CALIBRATE,AND BALANCE ENTIRE SYSTEMS. ® E BY ELECTRICAL CONTRACTOR iF DD D.D. DUCT SMOKE DETECTOR $� CFM CUBIC FEET PER MINUTEi of KITCHEN VENTLESS HOOD DETAILS CODE COMPLIANCE EA EACH J Q THE 2007 EDITION OF THE CALIFORNIA MECHANICAL CODE f MIN. MINIMUM t THE 2005 EDITION OF THE CALIF. ENERGY EFFICIENCY ABV _J W m STANDARDS. Q BEL. BELOW z 8 �f 6 EXIST. EXISTING Q m- = W f 1YP. TYPICALU UTR UP THRU ROOF L.Li O �p€3 W/ WITHCD g9 m( J u LLJ 0) O LLJ > Q W p U O w I— . Z O = Z U v) Q Lp W N w 1 r7 Q p(L ESSIgf P 44♦,yT f No.M027906 * EXP 6 CHAN�Y� Q OF CALIF Drown by RS Checked by Dote 3-20-09 Job No. Sheet Number M1 Of Sheets 0 � V CONSTRUCTION NOTES: V (U a N Ca tO NEW "GILES" VENTLESS FRYER HOOD. SEE MFR'S. SPECS. +1 m SEE INSTALLATION DETAIL ON SHEET M-1. 2O EXISTING OVEN AND HOOD TO BE REUSED. I a L m L L *HOOD SPECIFICATIONS: HOOD= "GILES"MODEL FSH-2 VENTLESS FRYER HOOD W/ �� d ANSUL R-102A FIRE SUPPRESSION c a ec rc ase 83"H x 24"W x 31"DEEP g 462 LES. �D e SEE MFR'S..SPECS. Lu [h d cc -C Lr) it U a a v 3� c a ec rc ase wo.u.c..cnw..� •.oneo..> •.cmvFm.u.c•.ma.u� c n ec r nseIg COOLER WALK-IN a ❑ � ® 's r, �6 i FRE2.WALK-IN So 4 �a ❑ _I z El c n e� r Q QEXXI z DINING Q 13ARFET/SALAD O - = 0 U LLJ J n�nnn � J CW N p > DISHWASHING 0 Q W U � O ® z LLJ Dr Q EXISTING MEWS EXISTING J WOMEN -i RESTROOM 'S � RE 9TROOM ec a ec rc nse N W e j.IIic ec rc nse ucnnviwo.c•.c•.m . nevwo.u.cn rnw..� acnewmo.a•.<rcnaouo L-I a ec rc ase N r7 Y g Q � J a �Ess, ar a c rc nse � A1027906 XP.10 k 4-kHAMU� 4 OF GUf Drown by IRS Checked by Dote 3-20-09 Job No. MECHANICAL FLOOR PLAN SCALE: 1/4"=1'-0" 1/4" Sheet Number M2 Of Sheets I n _.._.............. PLUMBING GENERAL NOTES PLUMBING LEGEND /1 PLUMBING FIXTURE SCHEDULE /�' 1. THE PLUMBING SYSTEM DESIGN, INSTALLATION AND MATERIALS SHALL CONFORM TO THE LATEST SYMBOL ABBREV. DESCRIPTION MINIMUM CONNECTION SIZES EDITION OF THE UNIFORM PLUMBING CODE (IAPMO) AND LOCAL CODES AND AUTHORITIES HAVING -- JURISDICTION. S OR W SOIL OR WASTE (ABOVE GRADE) _ MARK FIXTURE DESCRIPTION/REMARKS S OR W SOIL OR WASTE (BELOW GRADE) 2. PLUMBING QUALITY AND WEIGHTS OF MATERIALS, ALTERNATE METHODS OF CONSTRUCTION SH A'_L ��� E W V CW HW GAS CONFORM TO THE LATEST EDITION OF THE UNIFORM PLUMBING CODE. 0 ----- V VENT u HS HAND 1 , (PROVIDED BY TENANT) 3. CONTRACTOR SHALL COORDINATE ALL WORK SHOWN ON THESE DRAWINGS AND SPECIFICATIONS WITH (' CD- CD CONDENSATE DRAIN v N ci 2" {2 1/2" 1/2" - ALL DISCIPLINES AND TRADES PRIOR TO SUBMITTAL OF BID AND INSTALLATION OF SYSTEM. -- u 1 SINK __ CW COLD WATER 4. ALL PLUMBING FIXTURE LOCATIONS ARE DIAGRAMMATIC AND CONTRACTOR SHALL REFER TO ePS _ EQUIPMENT AND/OR ARCHITECTURAL DRAWINGS FOR EXACT LOCATION, MOUNTING HEIGHTS, HW HOT WATER PREP 1 SINK 2 11i1 1/2 1/2 (PROVIDED BY TENANT) TYPE AND COLOR. HWR HOT WATER RETURN FS FLOOR _ _ J. R. SMITH SERIES 3000, FLOOR SINK, ACID RESISTANT, CAST IRON 5. ANY DEVIATIONS FROM THE DRAWINGS OR SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION G G GAS (LOW PRESSURE) =i SINK 2 1lh 1/2 RECEPTOR, SEDIMENT BUCKET AND TOP GRATE OF THE ARCHITECT AND ENGINEER PRIOR TO INSTALLATION. - -MPG- MPG GAS (MEDIUM PRESSURE 5 PSI) 6. THESE DRAWINGS DO NOT INCLUDE ALL NECESSARY SAFETY REQUIREMENTS, CONTRACTOR TO /7� Q $ 3-COMP COMPLY TO SAFETY REQUIREMENTS SET FORTH BY THE LOCAL AUTHORITIES HAVING -SD- SO STORM DRAIN V�J. E r_ 2 111A 1/2 1/2 _ (PROVIDED AND RELOCATED BY TENANT) JURISDICTION, FCO FLOOR CLEANOUT SINK d 1 7. CONTRACTOR SHALL VISIT SITE PRIOR TO SUBMITTAL OF BID AND FAMILIARIZE HIMSELF WITH _. EXISTING CONDITIONS. SUBMITTAL OF BID WILL VERIFY THAT THE CONTRACTOR HAS VISITED COTG CLEANOUT TO GRADE THE SITE. -------- WCO WALL CLEANOUT M n 8. TRAP PRIMERS FOR FLOOR DRAINS AND WATER HAMMER ARRESTORS, IF APPLICABLE, TO BE �- SOV SHUT-OFF VALVE (BALL VALVE) _ U INSTALLED AS PER THE LATEST UPC AND THE LATEST EDITION OF THE AMERICAN SOCIETY OF _ I SANITARY ENGINEERING (ASSE 1010) SIZING AND INSTALLATION REQUIREMENTS. '~ - � pi C.V. CHECK VALVE __ ___ ^ 6 yl 9. ALL SERVICE WATER HEATING EQUIPMENT TO BE IN COMPLIANCE WITH ALL CALIFORNIA ENERGY LjF G.C. GAS COCK C J C in STANDARDS REQUIREMENTS AND APPLICABLE REGULATIONS HAVING JURISDICTION. r1 Cr U C ---�- SOV SHUT-OFF VALVE IN YARD BOX 10. CONTRACTOR TO REFER TO PLUMBING FIXTURE SCHEDULE FOR INDIVIDUAL WASTE, VENT& WATER F � ----' - '---_--- CONNECTIONS AT EACH PLUMBING FIXTURE. '11 U UNION I 11, ALL HOT& COLD WATER PIPING TO BE INSULATED AS PER LOCAL CODE REQUIREMENTS: G.V. GATE VALVE -- PIPE SIZE INSULATION THICKNESS INSULATION VALUE (E) EXIST. EXISTINGI 1/2" - 1" 1" R = 4.0 e POD POINT OF CONNECTION ayl 1-1/4" - 4" 1-1/2" R = 4.0 T/PRV TEMPERATURE & PRESSURE RELIEF VALVE 66■I -- 12. TEST SYSTEM(S) IN ACCORDANCE WITH REQUIREMENTS OF THE GOVERNING AUTHORITIES. VTR VENT THRU ROOF gl 13. STEEL PLATE SUPPORTS FOR ALL WALL FIXTURES: SUPPORT WITH 3/8" THICK x 8" HIGH STEEL CONN CONNECTION PLATES RECESSED AND BOLTED TO STUDS AND TAPPED FOR FIXTURE BOLTS. LENGTH OF PLATE MATERIALS AT LEAST ON STUD BEYOND FIXTURE, UNLESS CARRIERS ARE SPECIFIED. FU FIXTURE UNITS 14. ALL PLUMBING WORK SHALL BE INSTALLED SO AS TO AVOID INTERFERENCE WITH ELECTRICAL AND GPM GALLONS PER MINUTE °Q! S NOTES MECHANICAL EQUIPMENT AND STRUCTURAL FRAMING, SERVICE AP ACCESS PANEL QI w 15. ALL INDIRECT WASTE PIPING ON ROOF SHALL BE TYPE "L"' COPPER NAILED TO 2" x 4" gg REDWOOD BLOCKING WITH PIPE STRAPS. BLOCKING SHALL BE SET IN MASTIC AT 6'-0" O.C. W/ WITH B; ` $ PIPING SHALL BE SLOPED TO AND TERMINATED AT AN APPROVED RECEPTOR. - el ON DOWN Ln gf WATER INSIDE LEAD FREE SOLDERED RIIINGS 16, ALL CLEANOUTS SHALL BE INSTALLED WHERE READILY ACCESSIBLE AND LOCATED AS PER CODE -- LLJ OUTSIDE LEAD FREE SOLDERED FITTINGS REQUIREMENTS. THE CONTRACTOR SHALL COORDINATE ALL CLEAN OUT LOCATIONS WITH TYP, TYPICAL z J I ABV. FLR. TYLER 4-BAND NO-HUB COUPLINGS EQUIPMENT, CABINETS, ETC., AND THE ARCHITECT PRIOR TO ANY INSTALLATION. WASTE BEL. FLR. TYLER 4-BAND NO-HUB COUPLINGS 17. ALL PLUMBING FIXTURE VENTS TO TERMINATE A MIN. OF 12 INCHES FROM ANY VERTICAL VENT ABV. FLR. TYLER 2-BAND NO-HUB COUPLINGS SURFACE AND 10 FEET FROM OR TERMINATED 3'-0" ABOVE ANY OUTSIDE AIR INTAKES. W i� BEL. FLR, TYLER 4-BAND NO-HUB COUPLINGS 18. ALL PIPING DISCHARGING INTO FLOOR-SINKS AND/OR FLOOR-DRAINS TO HAVE A MIN, AIR-GAP = e� INDIRECT INSIDE (� =MEEWLDEREDO OEREO FITTINGS AS REQUIRED BY LOCAL CODES, J UI WASTE OUTSIDE t� OLDERED FITTINGS 19. ALL VALVES, UNIONS, ETC. TO BE SAME SIZE AS LINE SIZE UNLESS OTHERWISE INDICATED ONSTORM ABV. FLR. D NO-HUB COUPLINGS DRAWINGS.DRAIN BEL. FLR. t+ LD FITTINGS20. UNIONS SHALL BE PROVIDED AND INSTALLED AFTER EACH SCREW-TYPE VALVE AND PRIOR TOFGASINSIDE FITTINGS-SCREWED FIRINGSEQUIPMENT CONNECTIONS. OPIPING OUTSIDE f.,NGS-SCREWED FITTINGS,ON ROOF J U0 21. ALL VALVES, TRAP PRIMERS, WATER HAMMER ARRESTORS OR OTHER EQUIPMENT SHOWN IN WALLS LL.I i) OR ABOVE NON-ACCESSIBLE CEILINGS SHALL BE INSTALLED BEHIND AN ACCESS PANEL. 0) °I COLD WATER SIZING TABLE 22. BEFORE FABRICATION OR INSTALLATION, THIS CONTRACTOR SHALL VERIFY EXACT LOCATIONS OF � �I ALL MECHANICAL EQUIPMENT AND EQUIPMENT PROVIDED UNDER ANOTHER SECTION OF --- ---- --------- -- Q PIPE SIZE 1 2" 3/4" 1" 1-1/4" 1-1/2" 2 2-1/2" SPECIFICATIONS, EXACT ROUGH-IN LOCATIONS AND REQUIREMENTS SHALL BE COORDINATED IN _ _ LLl 0 C.) iI E F.U., F.T. 6.0 16.0 34.0 54.0 85.0 275 475 23. IF SOILS REPORT INDICATES THAT LOCAL SOIL IS CORROSIVE, ALL UNDERGROUND METALLIC z e! PIPE AND FITTINGS SHALL BE PROTECTED IN ACCORDANCE WITH THE SOILS ENGINEER'S Of F.U., F.V. 0 0 0 13.0 28 140 350 RECOMMENDATIONS. O �I Z ° GPM 5.0 12.5 22.0 30.5 40.0 77.5 119.0 24. ALL WASTE AND VENT PIPING SHALL SLOPE AT 2%UNLESS OTHERWISE INDICATED. CODE COMPLIANCE 25. ALL EQUIPMENT SHALL BE LATERALLY SUPPORTED IN ALL DIRECTIONS. Q W AS REQUIRED BY LOCAL CODES. N pr) LL! I 26. NO PIPING SHALL BE DIRECTLY EMBEDDED IN CONCRETE OR MASONRY WALLS OR FOOTING. N Y !!: THE 2007 EDITION OF THE CALIFORNIA PLUMBING CODE (CPC) 27. ALL HORIZONTAL PIPING LINES EXTENDED AND CONNECTED TO EQUIPMENT SHALL BE RUN AT THE i g HIGHEST POSSIBLE ELEVATIONS AND NOT LESS THAN 6" ABOVE THE FLOOR TO PROVIDE THE 2005 EDITION OF THE CALIFORNIA ENERGY EFFICIENCY STANDARDS CLEARANCE FOR CLEANING, AT WALL OR COLUMN LOCATIONS, PIPING ROUGH-IN SHALL BE STUBBED IN WALLS WHENEVER POSSIBLE. pgpFESSII 28, THE PLUMBING CONTRACTOR SHALL VERIFY EXACT LOCATION, DEPTH AND SIZE OF ALL PIPING TO WHICH CONNECTIONS ARE REQUIRED AND SHALL COORDINATE ALL CONNECTIONS WITH THE GENERAL CONTRACTOR AND OTHER TRADES PRIOR TO BID. N0.E027906 29, ALL CONNECTIONS TO EXISTING SERVICES SHALL BE MADE SUCH THAT INTERRUPTION TIME WILL SCOPE OF WORK * '�CHANT��� BE AS SHORT AS POSSIBLE. THE CONTRACTOR SHALL GIVE THE OWNER'S REPRESENTATIVE '�q) CALIf \p SUFFICIENT NOTICE OF SUCH INTERRUPTION AND THE ACTUAL SHUT-DOWN TIME SHALL BE AT A TIME DESIGNATED BY THE OWNER'S REPRESENTATIVE. 1. INSTALL PLUMBING EQUIPMENT AND UTILITIES INCLUDING WATER, GAS, 30. ALL CUTTING OF EXISTING PAVING, WALKS AND/OR FLOORS SHALL BE BY MACHINE SAW CUTTING, WASTE/VENT PIPING, CLEANOUTS, HANGERS, SUPPORTS, VALVES, Drown by IRS HOLES FOR PIPES IN CONCRETE WALLS OR FLOORS SHALL BE DONE USING CORE DRILLING AND ACCESSORIES AND MATERIALS SHOWN ON THESE PLANS OR EQUIPMENT. AS NECESSARY IN COMPLIANCE WITH ALL CODES AND REGULATIONS Checked by HAVING JURISDICTION. Dote 3-20-09 31. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PATCHING AND REPAIRING ALL AREAS WHICH Job No. ARE EXCAVATED AND/OR DAMAGED BY HIS OPERATIONS. IN ADDITION, THE CONTRACTOR SHALL 2. TEST ENTIRE SYSTEMS IN ACCORDANCE WITH ALL CODES AND RESTORE TO THEIR ORIGINAL CONDITION ALL AREAS DAMAGED BY HIS OPERATIONS. REGULATIONS HAVING JURISDICTION. Sheet Number P1 O/ Sh'ets 0 L VTRI CONSTRUCTION NOTES: 1/2" 1 EXISTING 4" GREASE WASTE LINE BELOW GRADE Q y TO EXISTING 1000 GAL, GREASE INTERCEPTOR. \1 PS HS v3 VERIFY EXACT LOCATION PRIOR TO CONSTRUCTION. COTG I HS NOTE: 2 POC-CONNECT NEW WASTE LINE TO EXISTING WASTE E WHERE APPLICABLE LINE BELOW GRADE. VERIFY LOCATION PRIOR TO CONNECT NEW VENTS TO EX 1 2, CONSTRUCTION.3 POC-CONNECT NEW 3/4" CW AND HW LINES TO W V POC L EXISTING VENTS / / 3j, ?" N FS 4 � N m ME EXISTING CW AND HW LINES ABOVE CEILING. VERIFY -POC 1/2„ EXACT LOCATION PRIOR TO CONSTRUCTION. F o. p0 (E)DW � 4 2"W.,DN., 1-1/2'V. UP FOR FLOOR SINK. -cp 1/2" i HS SINK 5 2"W.,DN. SPILL TO FS-1, 1/2" CW, HW. a Y3"VTR -1 (E)WH 6 2"W.,DN., 1-1/2"V. UP, 1/2" CW AND HW. L �? 7 NOT USED 4 0 O 5 a FS HE 8 NOT USED •'� d kl )a, WCO 9 1/2" CW LINE DN. IN WALL. STUB-OUT W/ SOV FOR 3 MS DRINK STATION. ° FS CW/HW ISOMETRIC W ti ° ^ NOTE: ALL UTILITY LINES AND POINTS OF CONNECTION ARE APPROXIMATE AND SHALL BE VERIFIED IN FIELD PRIOR TO WASTE/VENT ISOMETRIC Q � WCO ANY CONSTRUCTION. � -C rn ix (E) GREASE I / ; INTERCEPTOR — — — —(E)4"GW—UNK (1000 GAL.) I D TATIOf 9 FS PS s I 4 1 1 5 NEW PREP.SINK a L — -- — — J DRINK STATION Ch 6 RELOCATED 11 — — — HAND SINK a� COOLER WALK-IN Q � EXISTING DINING 3,. I z FREZ.WALK-IN m �; Q Q J _J El (L LL_ 3/4' B h� EXISTING DINING EXI5TING OVEN t HOOD. 0 BUFFEV5ALAD .,J L0 BAR 3" LLJ n Q N RELOCATED 6 . � � MOP SINK I I g El- rzi F__1 F O w �H FS ❑ I— Z CC 4 1 = Q O C0 RELOCATED z -i 3-COMP.SINK Q `� CO 2" N _ LLJ EXI5TING DINING 4 1 N Y 1 3/4"DI5 A511ING Je EXISTING MENS EXISTING 3 RE5TROOM W0MEN'5 "-- RE5TROOM WCO 027906 XP. 0 IXISTING HOT WATER HS 6 NEW HAND SINK P� 15 A.O.SMITH �qrf Cp MODEL#BTN480108 a GUE 180,000 13Tu'5(GAS) Drawn by RS Checked by Dote 3-20-09 Job No. PLUMBING FLOOR PLAN SCALE: 1/4"=1'-O" 'I Sheet Number P2 Of Sheets