HomeMy WebLinkAboutZCPC-2025-0028 Approved Plans DPV
STUDIO
PROPOSED NEW 2-CAR GARAGE (400 SQ. FT.)
2130 Huntington Drive Unit#310
South Pasadena,CA 91030
31077 ILLINOIS STREET. Cell:email:
email:dionvelasco@gmail.com
LAKE ELSINORE, CA 92530 PROJECT NAME&ADDRESS:
ADAMS RESIDENCE
ABBREVIATIONS VICINITY MAP APPLICABLE CODES: SHEET INDEX 31077 ILLINOIS ST.
0 DIAMETER CONSTR. cousmucnoN GA. caucE N Noem s SOUTH 2O23 CALIFORNIA ADMINISTRATIVE CODE (CAC) SHT. ARCHITECTURE LAKE ELSINORE, CA 92530
0 SQUARE FOOT/FEET COI. CONTINUOUS GALV. GALVANIZED N.LC. NOT IN CONTRACT S.A.T. SUSPENDED ACOUSTICAL 2023 CALIFORNIA BUILDING CODE (CBC) T-1.0 TITLE SHEET, ABBREVIATIONS, VICINITY MAP
& AND CONTR. CONTRACTOR G.C. GENERAL CONTRACTOR NO. NUMBER TILE
® AT CTSK COUNTERSUNK G.I. GALVANIZED IRON NON. NOMINAL S.C. SOLID CORE 2023 CALIFORNIA RESIDENTIAL CODE (CRC) A-1.0 EXISTING/PROPOSED SITE & ROOF PLANS
Q CENTERLINE C.Y. CUBIC YARD G.L.B. GLU-LAM BEAM N.T.S. NOT TO SCALE SCHED. SCHEDULE 2023 CALIFORNIA ELECTRICAL CODE (CEC) This document was created by Diet. No part of
POUND OR NUMBER GL. GLASS SECT. SECTION A-20 EXISTING FLOOR PLAN & PROPOSED FLOOR PLAN this document may be reproduced or used in
EXISTING 2023 CALIFORNIA MECHANICAL CODE (CMC) an farm except with the written permission of
DBL. DOUBLE ONE. GROUND O.A. OVERALL SIFT. SHEET Y P
DEPT. DEPARTMENT GR. GRADE O.C. ON CENTER sIFTc. SHEATHING - � -,,� . s � � 2023 CALIFORNIA PLUMBING CODE (CPC) A-3.0 PROPOSED ELEVATIONS & PROPOSED SECTION DIONICIA VELASCO.
A.B. ANCHOR BOLT BET. DETAIL GYP O.D. OUTSIDE DIAMETER SIM. SIMILAR �ti 2023 CALIFORNIA ENERGY CODE (CEEC) AE-1 PROPOSED ELECTRICAL PLAN
ABV. ABOVE . GYPSUM
D/F DOUGLAS FIR OFD. OVERFLOW DRAIN SPEC. SPECIFICATION 2023 CALIFORNIA FIRE CODE CFC
A/C AIR CONDITIONING - r j• ( )
D.F. DRINKING FOUNTAIN H.B. HOSE BIBB OPG. OPENING S0. SQUARE /�� - 2023 CALIFORNIA EXISTING BUILDING CODE CEBC T-24 TITLE 24 STAMP APPROVAL
A.C. ASPHALTIC CONCRETE ( )
DIM. DIAMETER H.C. HOLLOW CORE OPP. OPPOSITE SS. SERVICE SINK
A.D. AREA DRAIN DIM. DIMENSION �r � � rTF, - 2023 CALIFORNIA GREEN BUILDING STANDARDS CODE (CALGREE.
ACOUS ACOUSTICAL SS. STAINLESS STEEL
2023 CALIFORNIA REFERENCE STANDARDS CODE
AFF ABOVE FINISH FLOOR DN DOWN HT HARDWARE P.L. PARTITION STD. STANDARD CITY OF LAKE ELSINORE MUNICIPAL CODE
ALUM. ALUMINUM DR DOOR HT. HEIGHT P.L. PROPERTY LINE STL. STEEL r We
APPROX. APPROXIMATE DS DOWNSPOUT H.M. HOLLOW METAL PLAS. PLASTER STOR. STORAGE
ARCH, DWG. DRAWING HORIT HORIZONTAL PLBG. PLUMBING STRUCT. STRUCTURAL ARCHITECTURAL H.P. HIGH POINT PLYWD. PLYWOOD S.O.V. SHUT OFF VALVE
BD. BOARD E EAST HTG. HEATING P.O.C. POINT OF CONNECTION SYM. SYMMETRICAL
EA. EACH HDWID HARDWOOD PR. PAIR
BLDG. BUILDING E.C. EVAPORATIVE COOLER P.T. PRESSURE TREATED T TEMPERED ?
BLK. BLOCK E.J. EXPANSION JOINT HVAC HEATING,VENTILATION&
BLKG. BLOCKING ELEC. ELECTRICAL AIR CONDITIONING T.B. TOP OF BEAM
BM. BEAM EL ELEVATION I.D. INSIDE DIAMETER O.T. QUARRY TILE T.C. TOP OF CURB Q :S•„ l f
I.E. INVERT ELEVATION TEL.&G TELEPHONE SCOPE O F WORK
B.N. BOUNDARY NAILING E.P. ELECTRICAL PANEL IN. INCH R. RADIUS T&G TONGUE AND GROOVE
BOW. BOTTOM EQ. EQUAL INSUL INSULATION R ROOF DRAIN THK. THICK
BTWN. BETWEEN EQUIP. EQUIPMENT R.D.DWD. REDWOOD
TNT. INTERIOR T.J. TRIPS JOIST
C CAMBER E.W. EACH WAY REF. REFERENCE T.P. TOP OF PARAPET La
E%IS. EXISTING REFR. REFRIGERATOR
CAN CABLE TELEVISION E%T. EXTERIOR JT. JOINT REFRF REINFORCED T.S. TOP OF SHEATHING _ PROPOSED NEW 2 CAR GARAGE (400 SQ.FT.)
T.W. TOP OF WALL
C CATCH BASIN LAM. LAMINATED REQO. REQUIRED TYP, TYPICAL
CIE.EM. CEMENT FDN FOUNDATION LAV, LAVATORY RESIL RESILIENT
CER. CERAMIC F.D. FLOOR DRAIN LT. LIGHT RM. ROOM U.B.C. UNIFORM BUILDING CODE
C.H. CEILING HEIGHT F.F. FINISH FLOOR R.H.B. RECESSED HOSE BIBB U.O.N. UNLESS OTHERNSE NOTED
C.H.B. CONCEALED HOSE BIBB FIN. FINISH R.O. ROUGH OPENING 31077 ILLINOIS STREET.
C.I. CAST IRON FIXT. FIXTURE MAX. MAXIMUM R.O.W. RIGHT OF WAY LAKE ELSINORE, CA 92530
C/J CEILING JOIST M.B. MACHINE BOLT VERT. VERTICAL
FLR. FLOOR R.S. RESAWN
C.J. CONTROL JOINT MECH. MECHANICAL V.T.R. VENT THROUGH ROOF
F.L. FLOW LINE
CLG. CEILING FLUOR. FLUORESCENT MET. METAL W WEST PLANNING DIVISION
CITY OF LAKE ELSINORE
CLR. CLEAR F.H. TIRE HYDRANT MFR. MANUFACTURER W/ WITH
C.M.U. CONCRETE MASONRY UNIT F.O.M. FACE OF MASONRY M.H. MANHOLE W.C. WATER CLOSET
C/0 CLEANOUT F.O.S. FACE OF STUD MIN. MINIMUM WOOD PERMIT#ZCPC-2025-0028
C.O. CONDUIT ONLY F/S FINISH SURFACE misc. MISCELLANEOUS W.H. WATER HEATER ��//
COL. COLUMN F.S. FLOOR SINK M.O. MASONRY OPENING W/ REGISTRATION&SIGNATURE
GONG. CONCRETE FT. FOOT/FEET MTD. MO UN 0 WITHOUT
TED W WEAKENED PLAN JOINT
CONK. CONNECTION ITS. FOOTING MTW MAIN TELEPHONE w.R. WATER RESISTANT DATE:07/28/2025 7:42:40 AM
ELF. FUTURE MUL. UWONFURR. FURRING L W.W.F. WELDED YORE FABRIC APPROVED TITLE SHEET , SHEET
N.T.S. INDEX, ABBREVIATIONS, &
NORTH
GRAPHIC SYMBOLS MATERIAL SYMBOLS PROJECT SUMMARY BEST MANAGEMENT PRACTICES PROJECT DIRECTORY PROJECT ANALYSIS
PROPERTY TYPE: SINGLE FAMILY OWNER: KELLY ELIZABETH ADAMS
STUD PARTITION 31077 ILLINOIS STREET.
DETAIL NUMBER
ASSESSORS PARCEL NO: 379212010 BEST MANAGEMENT PRACTICES LAKE ELSINORE, CA 92530 ISSUES/REVISIONS:
MASONRY WALL TYPE OF CONTRUCTION: V-B FOR CONSTRUCTION ACTIVITES*
SHEET NUMBER � INITIAL PLAN, MARCH 2O25
OCCUPANCY: R-3 Storm Water Pollution Control Requirements for Construction Activities
ELEVATION NUMBER °co;:':. O;o°4 CONCRETE Minimum Water Quality Protection Requirements for All Development Construction 1
LOT PARCEL: 52 ••• Projects/Certification Statement DESIGN & DRAFTING: DIONICIA VELASCO PLANNING DEPARTMENT CORRECTION
A SHEET NUMBER 3130 HUNTINGTON DRIVE #110
ZONING: R2 MEDIUM DENSITY The following is intended as minimum notes or as an attachment for building and grading plans and SOUTH PASADENA, CA. 91030 MAY 29, 2025
EARTH OR COMPACT FILL RESIDENTIAL DISTRICT represent the minimum standards o(good housekeeping that must be Implemented on all construction
1 SECTION ELEVATION N0. sues regardless ofarze.(Applies to all permits) OFFICE: (951) 475-0211
NUMBER OF STORY: 1 dionvelascoOgmail.com
SHEET NUMBER DRAINAGE FILL Every effort should be made to eliminate the discharge of non-stormwater from the project site at all times.
YEAR BUILT: 1949
SECTION ELEVATION NO. • Eroded sediments and other pollutants must be retained on site and may not be transported from the site via
METAL
SPRINKLERS: NONE sheetfl—,swales,area drains,natural damage egurses or wend.
SHEET NUMBER E LOT AREA: 4,791 SQ. FT. S by ki,lles of earth and the forces of her windwater.kuclion related materials must be protected from being transported from the
O sit. STRUCTURAL ENGINEER: TERENCE CHANG
BUILDING SECTION NO. BATT INSULATION Fuels,oils,solvents and other toxin materials must be stored In accordance with their listing and are not to 3579 E. FOOTHILL BLVD. #206
1 1 (E) LIVING AREA 587 SQ. FT. contaminate the soil and surface waters.All approved storage.-Isiners are to be protected from the PASADENA, CA 91 107
SHEET NUMBER weather
. FT. Spills
ash ge system.up immediately and disposed of in a proper manner.Spills may not be
(N) GARAGE 400 SQ washed int thed
® � WOOD, CONTINUOUS BLOCKING (626)379-4900
Excess or waste concrete may t be washed into the uric wayother drainaesstem.Provisions tchanpe@gmail.com
O DOOR NUMBER yno May can Posenyo g y
EXISTING LOT COVERAGE: shall be made to retain concrete wastes on site until the be disposed of as solid waste.
® FINISHED WOOD Trash and construction related solid wastes must be deposited into a covered receptacle to prevent
O WINDOW NUMBER LIVING AREA/ EXISTING LOT cuntaminatnn of rainwater and dispersal by wind. JOB NUMBER: DV2025-005
GYPSUM WALLBOARD 587/4,791— 13% Sediments and other materials may not be tacked from the site by vehicle traffic.The construction entrance DRAWN BY: DIONICIA VELASCO
roadways must be struill so as to Inhibit sediments from being deposited into the public way.Accidental
ROOM NUMBER depositions must be swept up immediately and may not be washed down by rein or other means. TITLE 24 CALCULATIONS: PERFECT DESIGN PLOT DATE: APRIL 2025
PLYWOOD L
POSED LOT COVERAGE: Any slopes with disturbed soils or denuded of vegetation must be stabillzed so as to inhibit erosion by wind M ECH ANI CAL,ELECTRI CAL,PLU M BI NGand water. ENGINEER PERMIT #
GRID LINE NUMBER G AREA+ (E) GARAGE, NEW ADU/ EXISTING LOT L\ RAYMOND ZHNNG �1f�Pf�� AoAS�oOAORIGID INSULATION 400/ 4,791- 21% I certifythattisdocumentandallattachmentswerepme redundermydimdionorsupervisioninaccordance 2416 W. VALLEY BLVD. LV V L ! Lv❑ hha system designed to ensure that qualified personnel property gather antl evaluate the informaton submitted. ALHAMBRA, CA. 91805
FINISH ITEM NUMBER % (MAX LOT COVERAGE) Based on my mquiry of the person or persons who manage the system or those persons directly responsible for OFFICE:
gathedmg the information,to the best of my knowledge and belief,the Information submitted is tine,accurate,and
0'-0„ PARTICLE/FIBER BOARD -mplele. am aware that submitting false and/or inaccurate information,failing to update the ESCP to reflect (626) 289-8809 SHEET CONTENTS:
NOTE TE current conditions,or failing to properly and/or adequately implement the ESCP may result in revocation of grading FAX:(626) 289-4913
SPOT ELEVATION antl/gr other permits or other sanctions provided by law."
MOISTURE RESISTANT BOARD
Print Name
PROPOSED NEW 2-CAR GARAGE (20'x20'). CURRENT REMODEL OF (Owner or authorizetl agent of the owner)
EXISTING HOUSE IS UNDER SEPARATE PERMIT. signature GENERAL CONTRACTOR: M & LCONTRUCTION INC.
Data
(Owner or author zi etl agent of the owner) LICENSE B # 1125060
4200 CHINO HILSPWY SUITE 135-291, SHEET NUMBER:
one eu�•e ago11 1.1. 111.C. ,•�e111 1a1„•n•stet•,Qi CHINO HILL, CA 91709
mlcontructionservice@outlook.com TI ■
PROPERTY LINE 100' DPV
I EXISTING O EXISTING 6'-0"
1 6,-0„ HIGH WOOD FENCE I STUDIO
HIGH WOOD N DRAIN
FENCE 2% I
20-O I 2130 Huntington Drive Unit#310
South Pasadena,CA 91030
1 I ~ Cell:951-475-0211
1 I
W email:dionvelasco@gmaii.com
OI PROJECT NAME&ADDRESS:
W I �ffi PROPOSED DRAIN 011
z GARAGE o DRIVEWAY I 2%400 SF. N I ADAMS RESIDENCE
cn
�I I 31077 ILLINOIS ST.
ch�
I I LAKE ELSINORE, CA 92530
n
OI —
W 1 O This document was created by DPV. No part of
W 7-0 DRAIN this document may be reproduced or used in
1 2% z Dny form except with the written permission of
TONICIA O
1 0 P °
91P 5O—3 J STAMP APPROVAL
I EXISTING HOUSE 1 0
i 587 SF.
Ln
IW
I 1 z CITY OF LAKE ELSINORE
1
I o o� J a PLANNING DIVISION
DRAIN in a m I PERMIT#ZCPC-2025-0028
N o I a Jr—gpcd m
o W DATE:07/28/2025 7:42A7 AM
1 DRAIN (E) TREE I O APPROVED
1 2% �9 1 W / — — — — — — —— — — — — — — `
IEXISTING o o 1 6'-0" o�
HIGH WO HIEX Q
O O A I1 ISTING I r FENCE GH I
WOOD FENCE
PROPERTY LINE 100'
I I
DORMER VENT I NFV:99 SCAN. REGISTRATION&SIGNATURE
I I I I
EXISTING/PROPOSED SITE PLAN I 4
I � I
SCALE : 3/16"=1'-0" I IF �L I
�oPy I � I
I
(N) CRICKET I
�_(N) SHINGLE ROOF
ISSUES/REVISIONS:
W/2#15 FELT PAPER)L 1 PROPOSED
FLAT ROOF
J I 400 SF. i INITIAL PLAN, MARCH 2O25
A//��
PLANNING DEPARTMENT CORRECTION
J
a12 MAY 29, 2025
I 4:12 4:12 T
SCOPE OF WORK: /
PROPOSED NEW 2 J
CAR GARAGE (400
SQ.FT.)
III EXISTING^HOUSE III
LJ
JOB NUMBER: DV2025-005
a DRAWN BY: DIONICIA VELASCO
L, PLOT DATE: APRIL 2025
\V/ PERMIT #
a EXISTING
ZCPC. 2025.0028
SHINGLE ROOF
1 4:12 4 1
SHEET CONTENTS:
-- EXISTING/PROPOSED
J SITE & ROOF PLAN
SHEET NUMBER:
A2 EXISTING PROPOSED ROOF PLAN
■
WALL LEGEND
:EXISTING STUD WALL 2x4 AS BUILT
W/R13 INSULATION
:EXISTING STUD WALL 2x4 AS BUILT P V
C— TO BE DEMOLISH
:1-HOUR FIRE RATED WALL STC-50 STUDIO
3 AA
A-3.0 A-3.0 2130 Huntington Drive Unit#310
ELECTRICAL LEGEND South Pasadena,CA91030
Cell:951-475-0211
email:dionvelasco@gmail.com
20'-0' ® 5X AIR HAUSCHANGESFANi PO R HOUR
HUMIDITY CONTROLLED PER CALGREEN PROJECT NAME&ADDRESS:
4.506A
FIRE PROTECTION ADAMS RESIDENCE
r 31077 ILLINOIS ST.
C0 MlONOXDE DE ALARM BATTERY OPERAT o WITH VOICE LAKE ELSINORE, CA 92530
ALERT.
MODEL#: KN-COSM-XRT-B
HARDWIRES W/BATTERY BACKUP
NOTE: INSTALL WHERE NOT PRESENT&REQUIRED This document was created by DPV. No part of
12'-11" this document may be reproduced or used in
OSMOKE DETECTOR, HARDWIRED WITH BATTERY any form except with the written permission of
BACKUP (ONLY), INSTALL IF NOT PRESENT OR DIONICIA VELASCO.
PROPOSED GARAGE REPLACE FOR REQUIRED
400 SF.
�)DIOIALARMS IS REQIRED TTHY SHALL BBE MONOXIDE
() STAMP APPROVAL
0" INTERCONNECTED SO THAT THE ACTIVATION OF
ONE (1) ALARM WILL ACTIVATE ALL ALARMS)
o
o ❑D ❑D
�. LAUNDRY - AUNDRY 3 CITY OF LAKE ELSINORE
/ (E)DOOR m A-3.0
I _/ re)Doan L
PLANNING DIVISION
3a xao ENCLOSED PORCH '� 3a xao ENCLOSED PORCH PERMIT#ZCPC-2025-0028
'J"g�
DATE:07/28/2025 7:42:52 AM
BATH BATH APPROVED
(E)DOOR IQ DOOR
a 36-x80- L(E)DO. 36x80' (E)DOOR^. 30'xa0'
(E)
26'x80' 2C'x80'
(E)DOOR (E)DOOR
2 32°.8o° $ 4 32'.ao' $
REGISTRATION&SIGNATURE
BEDROOM BEDROOM
�a �e
KITCHEN it KITCHEN
LL.SET LJOSET
'} '} } ISSUES/REVISIONS:
00 (E)DDOR { (E)D-T
3o•xao 3o•xao F INITIAL PLAN, MARCH 2O25
L\ PLANNING DEPARTMENT CORRECTION
MAY 29, 2025
10'-2" 9'-11" 3'-0" 10'-2"
1
A-3.0
EXISTING FLOOR PLAN �o EXISTING FLOOR PLAN yo
SCALE : 1/4"=1'-0" y�I SCALE: 1/4"=1'-0" P�
JOB NUMBER: DV2025-005
DRAWN BY: DIONICIA VELASCO
PLOT DATE: APRIL 2025
PERMIT #
ZCPC. 2025.0028
SNEET CONTENTS:
EXISTING $ PROPOSED
FLOOR PLAN
SHEET NUMBER:
A=2mo_
DPV
STUDIO
(N) SHINGLE ROOF
(CLASS"A" (N) SHINGLE ROOF
W/2#15 FELT PAPER) (CLASS "A" 2130 Huntington Drive Unit#310
——————————————————————————— —TOP OF ROOF LGARAGEL W/2#15 FELT PAPER) —— —TOP OF ROOF GARAGE) South Pasadena,CA 91030
— ————————————————————————————————————— —
o (N) CRICKET ,2 ,ems Cell:951-475-0211
b email:dionvelasco@gmail.com
—— — _— —— —————— TOP OF PLATE AR _— - - :. — —_—— ———— ——Z PROJECT NAME&ADDRESS.
' — TOP OF PLATE GARAGE
/ o ADAMS RESIDENCE
31077 ILLINOIS ST.
LAKE ELSINORE, CA 92530
\ - \ This document was created by DPV. No part of
FIN F1 OCR (Q'ARAGF) — — —— \ : this document may be reproduced or used to
FIN, FLOOR (GARAGE) any form except with the written permission of
DIONICIA VELASCO.
STAMP APPROVAL
PROPOSED SOUTH ELEVATION PROPOSED EAST ELEVATION
SCALE 1/4"=1'-0" L SCALE 1/4"=1'-0"
CITY OF LAKE ELSINORE
PLANNING DIVISION
PERMIT#QQZCPC-22025-0028
(N) SHINGLE ROOF (N) SHINGLE ROOF ✓ �` ,-r�
(CLASS"A" (CLASS"A"
TOP OF ROOF(GARAGE) �2#15 FELT PAPER) TOP OF ROOF-CGARAGE� —— W/2#15 FELT PAPER)— DATE:07/28/2025 7:42:57 AM
—————————
APPROVED
12 iz
O
O 44
� 12 12
44
TOP OF PLATE (GARAGE) TOP OF PLATE
_(GARAGE)_
o o REGISTRATION&SIGNATURE
ME
FIN, FLOOR (GARAGE)
FIN, FLOOR (GARAGE)
ISSUES/REVISIONS:
PROPOSED NORTH ELEVATION PROPOSED WEST ELEVATION
SCALE 1/4"=1'-0" G SCALE 1/4"=1'-0" INITIAL PLAN, MARCH zozs
F=WHTE-DE1741
INISH
L\ PLANNING DEPARTMENT CORRECTION
OLOR OF THE NEW GARAGE
EXISTING HOUSE(BONE MAY 29, 2025
DUNN EDWARDS)
, BASE 100 (LA HABRA)
— — —— — — TOP OF ROOF(GARAGE_
4� a4
I
——————— JOB NUMBER: V —
(s)a.a aRA.E TOP OF PLATE (GARAGE)
DRAWN BY: DIONICIA VELASCO
PLOT DATE: APRIL 2025
PERMIT #
ZCPC. 2025.0028
I
NEW GARAGE
SHEET CONTENTS:
PROPOSED
FIN FLOOR (GARAGE) ELEVATIONS AND
.)s AS—N.—N, SECTION
SEE smucmeaL PLAN SHEET NUMBER:
SECTION (NEW GARAGE)
SCALE 1/4"=1'-0"
■
ELECTRICAL LEGEND
® 5X AIR S HANGESI PER HOUR
HUMIDITY CONTROLLED PER CALGREEN
llll 4.5013.1
OUnra ELECTRICAL OUTLET, TYP., AFCI P V
ELECTROR 36" OFFGRAL TLET OUND,(OARCICCFCI) STUDIO
NTER
20'-0"
Lo, ` GFCI ELECTRICAL OUTLET
g ci (W) — WALL MOUNTED OUTLET, AFCI
GFCI u«r ELECTRICAL OUTLET W/LID, AFCI, GFCI 2130 Huntington Drive Unit#310
AFCI South Pasadena,51-475-211 30
LIGHT SWITCH WITH WHITE FACEPLATE email:dionvelasco@gmail.com
GF $ (DIMMER)IGHT SWITCH WITH WHITE FACEPLATE
PROJECT NAME&ADDRESS:
LED TYPE LIGHT FIXTURE
r r@ 6" RECESSED LIGHT FIXTURE ADAMS RESIDENCE
— I cJ WALL MOUNTED LIGHT(LED TYPE)
i 0 LED GARAGE LIGHTING 31077 ILLNOIS ST.
__------- LAKE ELSINORE, CA 92530
WALL LEGEND This document was created by DPV. No part of
this
y form except awith they be or used i permission an of
i DIONICIA VELASCO.
� 0 :EXISTING STUD WALL 2x4 AS BUILT
W/R13 INSULATION
i
STAMP APPROVAL
i
i :NEW STUD WALL 2x4 @ 16" TYPE'X' &W.P.
� AT WET WALL
pq
PROPOSED GARAGE _ :1—HOUR FIRE RATED WALL STC-50
I 400 SF. o
I
I
CITY OF LAKE ELSINORE
PLANNING DIVISION
' PERMIT#ZCPC-2025-0028
_ DATE:07/28/2025 7:43:01 AM
U APPROVED
O
� I
� � I
LLB C
V
0 J REGISTRATION&SIGNATURE
I
z
LLw
GFCI
RG F I AFCI
ISSUES/REVISIONS:
PROPOSED ELECTRIC PLAN NEW GARAGE INITIAL PLAN, MARCH 2025
SCALE : 3/8"=1'-0"
L\ PLANNING DEPARTMENT CORRECTION
NORTH
MAY 29, 2025
JOB NUMBER: DV2025-005
DRAWN BY: DIONICIA VELASCO
PLOT DATE: APRIL 2025
PERMIT #
ZCPC. 2025.0028
SHEET CONTENTS:
PROPOSED ELECTRIC
PLAN
SHEET NUMBER:
PROPERTY LINE 50'
rEXISTING
1 6'-0" HIGHI DPV
WOOD FENCE 2� 1
OftAIN ?y
�Rti STUDIO
EXISTING 6'-0" �
HIGH WOOD FENCE
2130 Huntington Drive Unit#310
1 1
� o I South Pasadena,CA 91030
Cell:951-475-0211
—O 27 I email:dionvelasco@gmail.com
DRAIN '
1 I PROJECT NAME&ADDRESS:
EXISTING HOUSE
ADAMS RESIDENCE
1 1
31077 ILLINOIS ST.
0
a9 i LAKE ELSINORE, CA 92530
0
This document was created by DPV. No purl of
1 I this document may be reproduced or used In
any form except with the written permission of
DIONICIA VELASCO.
z
STAMP APPROVAL
1 1
SWALE
1 1
1 1
I tio�P`� PROPOSED a I
1 o I CITY OF LAKE ELSINORE
GARAGE
EXISTING 6'-0"�- 400 SF. PLANNING DIVISION
HIGH WOOD FENCE I PERMIT#ZCPC-2025-0028
1 I EXISTING 6 FEN ✓p>� Q
1 I HIGH WOOD FENCE
DATE:07/28/2025 7:43:06 AM
1 APPROVED
a
I 1
0 I I REGISTRATION&SIGNATURE
FIT�I I�
< I�
1 1
zI Iz
711 F1
1 1�
IO
_1 0
EXISTING 6'-0" ISSUES/REVISIONS:
EXISTING 6'-0" °�a o HIGH WOOD FENCE
HI SA WOOD FENCE i p - O z z I INITIAL PLAN, MARCH 2O25
DRIVEWAY a
PLANNING DEPARTMENT CORRECTION
p p o
1 po' g g p MAY 29, 2025
1 1
NOTES:
(E) TREE
1. NO VISIBLE OBSTACLES IN LOT
1 1
2. CODE REQUIRES WATER HAS TO BE DIVERTED
10' AWAY FROM FOUNDATION IF CERTAIN AREA
ARE NOT ABLE TO COMPLY WITH CODE, THEN
ASWALE MAY BE CREATED TO DIVERT WATER TO JOB NUMBER: DV2025-005
DRAIN PROPERTY TO NORMAL LOT FLOW. DRAWN BY: DIONICIA VELASCO
1 I
PLOT DATE: APRIL 2025
3. ONLY 8.5 CUBIC YARDS OF DIRT IS AFFECT PERMIT #
FOR THIS PROJECT. ZCPC. 2025.0028
I 1
------------------- --------- -----
PROPERTY LINE 50 SHEET CONTENTS:
PROPOSED
NO ISIBLE OBSTRUCTIONS TREET DRAINAGE PLAN
PARKWAY
SHEET NUMBER:
I L L I N O I S STREET � PROPOSED DRAINAGE PLAN ____
1LD= 1 I