HomeMy WebLinkAboutLAKE ST 61000_02-00001262 NAI City of Lake Elsinore PERMIT 130 South Main Street PERMIT NO: 02-00001262 DATE : 6/17/02 JOB ADDRESS . . . . . 61000 T LAKE ST DESCRIPTION OF WORK ELECTRICAL OWNER CONTRACTOR LONG BEACH EQUITIES INC BAY CITY ELECTRIC WORKS, INC . 1100 TOWN COUNTRY RD i1FL 12208 INDUSTRY RD ORANGE, CA 92668 LAKESIDE, CA 92040 619-938-8200 LIC EXP 0/00/00 A. P. # . . . . . 390-120-007 8 SQUARE FOOTAGE 0 OCCUPANCY . . . GARAGE SQ FT 0 CONSTRUCTION . . FIRE SPRNKLR VALUATION . . . ZONE . . . . . . (SP) ELECTRICAL PERMIT QTY UNIT CHG ITEM CHARGE BASE FEE 30 . 00 1 . 00 X 44 . 2500 MOTORS/TRANSFMER 50 - 100 44 . 25 1 . 00 X 5 . 0000 PROFESSIONAL DEV FEE 5 . 00 FEE SUMMARY CHARGES PAID DUE PERMIT FEES ELECTRICAL PERMIT 79 . 25 . 00 79 . 25 OTHER FEES PLAN RETENTION FEE 4 . 50 . 00 4 . 50 TOTAL 83 . 75 . 00 83 . 75 SPECIAL NOTES & CONDITIONS EMERGENCY BACK-UP GENERATOR FOR CELL SITE � 17/02 17� R�aei t 983.75 BP � P 8665618 City Of Lake Elsinore Building Safety Division Please Read and Initial: 1. I am Licensed under the provisions of Business and Professional Code Section 7000 et seq.and my license is in full force. Post in conspicuous place 2. 1.as owner of the property,or my employees w/wages as their sole compensation-will do the work and the structure is not intended or on the job offered for sale. 3. 1,as owner of the property,am exclusively contracting with licensed contractors to construct the project. You must furnish PERMIT NUMBER and the o . I have a certificate of con sent toseltlnsure Ora ceruflcateofWorkers JOB ADDRESS for each respective inspection: Compensation Insurance or a certified copy thereof: 5. l shall not employ any person in any manner so as to become subject Approved plans must be on job to Workers Coompensation Laws in the performance of the work for at all times: which this permit is issued. Note: Ifyou should become subject to Workers Compensation after making this certification,you must forthwith comply with such pro- visions or this permit shall be deemed revoked. Code Approvals Date Inspector EL01 Temp Elec Services PL01 Soil Pipe Underground EL02 Elec Conduit Underground BPO1 Footings BPO2 Steel Reinforcement BPO3 Grout BPO4 Slab Grade PLO1 Underground Water Pipe SS01 Rough Septic System SW0l On Site Sewer RP05 Floor Joists Electric-Conduit -2O �}GCi EL04 Rough Electric-WifingZy2 �k EL05 Rough Electric-T-Bar ME01 Rough Mechanical ME02 Ducts,Ventilatin PL04 Rough Gas Pipe-Test P1 02 Roof Drains BP10 Framina&Flashino BP12 Insulation BP13 Drywall Nailing BP11 Lathing&Siding PL99 Final Plumbin EL99 Final Electrical -i2-O ME99 Final Mechanical BP99 Final Building Code Pool&Spa Approvals Date Inspector OTHER DEPARTMENT RELEASES Der).Inspector Department Approval required prior to It* Pool Pool Steel Rein./Forms building being released by the City Pool Pool Plumbing/Press.Test P003 Pre-Gunite EL06 Rough Pool Electric Date Inspector Planning Sub List Approval Landscape P004 Pool Fencing/Access Finance P005 Pre-Plaster En ineerin ' P009 Final PooVSpa f 41 City of Lake Elsinore 130 South Main Street APPLICATION NO. APPLICATION FOR t9 z -� ELECTRICAL APPLICATIr RECEIVED PLUMBING PERMIT DATE , (_ ,Z- MECHANICAL APa By J 7Cl certify that I hove read this application and state that the BUILDING ADDRESS above information is correct. I agree to comply with oil city 6./000 T- Z-A S _49� �3qQ-(2Q- Off , 010 and county ordinances and state laws relating to building TRACT BLOCKiPAGE LOL/PARCEL 1 hereby affirm that I am licensed under provisions of Chapter 9(commencing with Section 7M)at Division 3 of the Business and Professions Code.and my license is in full force AGENT FOR X CONTRACTOR OWNER a LICENS�eff�t CITY BUSINESS 4&-so'k-, AND CLASS �`7 a/33 C/o TAX/� Kr/r/c� v�- PiA: A� AGENT'S NAME / IJC t' :aAnLNG -�^o IZ200' ��2—O A ADDRESS ��GC/O �-SmY �. AGENT'S ADDRESS Cry STATE ZIP PHONE STRE C1 Y STATE ZIe Lfq {!D G/¢ `IZO4IO (,/y-93, -�Z Lit 5 t D� c T ..,,0 DATE BUILDING PERMIT NO. ELECTRICAL Ouan PLUMBING Quon MECHANICAL Quart New Residential Multi Family Fixture or Trap Furnace up to 100,000 BTU's New Residential Single Family Building Sewer Furnace Over 100,000 BTU's Private Swimming Pools Rain Water Sys per Drain Floor Furnace/Vent Switches?1st 20 Private Septic System Unit Heater/Wall Heater Switches 9 Over 20 Water Heater Y Vent Install/Relocate/Replace Vent Recpt.Outlet/Ist 20 Gas Piping System 1-4 Outlets Ventilating Fan Recpt.Outlet/Over 20 Gas Piping 5 or More Outlets Exhaust Hood Lighting Fixtures n Ist 20 Dishwasher Fireplace Res.Fixed Appliance.,Outlet Solar Tank Commercial Incinerator Non-Res.Appliance 0 Outlet Solar Collector per Panel Air Handler► 10,000 CFM 100-200Amp Service-4 60DV Grease Trap i(Interceptor) Air Handler-4 10,000CFM 200-1ODD Amp Service-4 600V Install.Alter or Repair System Fire Dampers Service Over 1000 Amp or 600V Lawn Sprinkler System Registers Misc Apparatus.Conduits,ETC Backflow,Device Smaller than 2" Boiler/Compressor to 3 H.P. Signs Backflow Device Larger than 2" Boiler/Compressor 3-15 H.P. Sign Branch Circuit Floor Drain Boiler/Compressor 15-30 H.P. Buswoys/EA 100 ft Floor Sink Boiler/Compressor 30-50 H.P. Temporary Power Service Water Service Boiler/Compressor► 50 H.P. Temp.Power Distribution Sys. Alter or Repair Drain or Vent Repair/Alter Misc.HVAC Equip. MOTORS/TRANSFORMERS Fire Sprinklers per Building Motors up to 1 H.P. SWIMMING POOL Motors/Transformers I.10 H.P. Swimming Pool/Public Motors/Transformers 10-50 H.P. Swimming Pool/Private Motors/Transformers 50-100 H.P- Water Heater/Vent Motors/Transformers► 100 H.P. Replace Piping Replace Filter Misc.Replace Gas Piping REV.DATE 11.1.90 b-2,, jz�Z__ Bay City Electric Works , Inc ® ON t /N - .61000 T LAKE STREET D". • ®��, �� o ratC" LAKE ELSINORE ® C C1 -74 LC 0A&.1��� Project Data: .-,Icinity Map: General Notes : Contractor: -Proposed installation of 40KW Kohler Generator Bay City Electric Works,Inc. mounted to a 1209 Diesel fuel tank. 12208 Industry Rd Lakeside,CA 92040 *UL 142 listed fuel tank. 619-938-8200 *UL 2200 listed generator. Applicant: Site - Proposed 114" x 66" x 6" pad with 4" curb.#4 Verizon Wireless Re-bar, 12" on center. Bolts will go down 3 2'. 15505 Sand Canyon Ave. Irvine,CA 92618 949-286-7000 C'o�, 2' x 42° Hilti bolts will hold diesel fuel tank to pad,which will resist seismic damage in accordance Site Owner: with building code U.F.C. sec. 7902.1.9. Long Beach Equities Inc. to Vice Pres: Johnathan - Piping,valves,and fittings will conform to Frieman nationally recognized engineering standards, 2042 Arma Cost Ave. Los Angeles,CA 90025 - All necessary placards and signs will be posted on (310) 207-9969 the fuel tank and at the entrance to the fuel tank. 0 Municipality o 2 Jurisdiction: City of Lake Elsinore °,c� 1 o No Smoking Accessor's Parcel Number: 390-120-011,010 `y No Open Flames Electrical Engineer: Salvatore Martorana - All electrical equipment will be installed in Bay City Electric Works,Inc. accordance with electrical code 7901.4 U.F.C. 12208 Industry Rd Lakeside,CA 92040 - Fuel tank normal atmospheric vent 12' above 619-938-8200 grade. SINGLE LINE DIAGRAM ZONE I REV DESCRIPTION REVISIONS DATE APPROVED no S c Q ( e Note Q) Replace manual transfer switch with automatic transfer switch feed by new generator Note (2) Breaker mounted in generator from factory Line power 120/240v,200amp, 2"-3#3/0,(00) Note (3) 2-20 amp, 1P, 120v breakers for single phase battery charger and btock heater �u 120/240v, 225 amp, single phase load center 225 amp Rated Kohler, ATS, 120/240, single phase,3 POte,3R, WCR 200,000 see note (1) 2" EMT-3#3/0 (CU) See (1)2"EMT-3#3/0 (CU) Note (1)l"EMT-25 pair #24 AWG (3) 3-#14 AWG kLLY GTR1C�l1 B°4C (1) 1" EMT-6#12 THHN ?' 150 amp UL j Breaker ��®� See Note (2) ��c�Lt��Q Site: Walker Canyon BAY CITY ELECTRIC WORKS INC, 61000 T Lake St GFN Lake Elsinore, CA CANYON 40 kW Kohter Generator WALKER 120/240 single phase 5/8 x 8' Grounding rod SIZE I FSCM NO. DWG NO. REV connecting to generator Generator installations 06/03/02 grounding stud on alternator SCALE SHEET 1 of 1 REVISIONS Existing Gate 49' ZONE REV DESCRIPTION DATE APPROVED 12' — See General Notes (1) % x 1911, Existing See General Notes (2) Monopole Existing Fence 18' c� D \ n General Notes; e xisting Equipment Building 1) Proposed 114"x66"x6" concrete pad With 4 curb for containment, 12' 49' 2) Proposed 40KW Kohter 14'10' emergency standby generator, Existing Door I S' S 3,2}. 0 o E W 4 6' 3 71` ( Cc�RIc 4'3` 7 10'6` N 9 17'7' 4'6' �OF CAt e � Site:Walker Canyon BAY CITY ELECTRIC WORKS) INC. 61000 T Lake Street Lake Elsinore, CA WALKER CANYON Generator Installation SIZE I FSCM NO. DWG NO. REV 06-04-02 SCALE N/A SHEET 1 of 1 REVISIONS ZONE REV DESCRIPTION DATE APPROVED 4' A 114' `I L_ 10• 12' 6' if SECTI❑N A—A K❑HLER MODEL 40 RE❑ZJ DIESEL GENERATOR ; fi=k 66° WITH FUEL TANK 1z• n a, (82' X 31') 2' PVC PIPE WITH L❑CKING VALVE (EXTEND � PVC 2' FROM CURB — VALVElz- 3z PR❑VIDED BY BCEW) NLLY -A' , sr'TRIG � t A PLAN VIEW CURB GENERAL NOTES: CONCRETE HAS BEEN MEASURED AT A SITE: MINIMUM OF 3000PSI WITH A CURE RATE Walker Canyon BAY CITY ELECTRIC WORKS INC, 61000 T Lake St OF 28 DAYS. Lake Elsinore, CA WALKER CANYON SIZE FSCM NO. DWG NO. REV SCALE SHEET