Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
05-198
Underground Service Alert % EMERGENCY VEHICLE PHASE DIAGRAM CONDUCTOR SCHEDULE Call: TOLL f REE / PRE-EMPTION DETECTOR AWG SIZE CONDUIT SIZE AND RUN (MODEL 711) GROUP A GROUP B POLE OR 2` 3' 3.5" 4' 4" 2" 3" 2-4" 1-800 — CABLE TYPE CIRCUIT 1 2 3 4 s Qs AA 227-2600 TWO WORKING DAYS POLE - A BEFORE YOU DIG \ _ NO. 14 CABLES - 1 1 - - - - 1 I 1 1 C C B ;XI - I - _- -- _- -- I - 1 Most Arm PHASE 1 PHASE 2 PHASE 3 PHASE 4 N/12 N C _ -_ ;:-2;;12;;12- 2- 2- 2 P % / N DD 1 1 1 1 1 1 CO f UU E 1 1 1 1 1 1 jj F - - - - - - 1 1 1 1 g / - - - - - - - - - \\ \ / PHASE 5 PHASE 6 PHASE 7 PHASE 8 RR - - -- -- -- -- -- -- -- - 0O EMERGENCY VEHICLE PRE—EMPTION X PHASE 6 PEDESTRIAN INDICATORS SHALL READ'WALKMAN"DURING 06 GREEN, S S t 1 1 2 4 a a N 'HAND"DURING 06 YELLOW AND RED,AND BLANK DURING FLASHING. TOTAL CABLES-3 CONDUCT./12 CONDUCT.- 1 2 2 3 3 4 7 7 a DETECTOR MOUNTING DETAIL \� Not to Scale 12 ISNSING _ 2 2 2 2 2 2 - Z 2"C, 1 DLC&S.I.C. 6 SIGNAL SERVICE - - - - - - - 2 g C \ O TOTAL CONDUCTORS - 4 4 4 4 4 4 2 W TYPE 'B' DLC 01 LOOP LEAD-IN - - - 1 1 1 i N a 02 2 2 2 2 n / o cqy STANDARD PLACEMENT DETAIL 04 - - _ _ 2"C, 1 DLC&S.I.C. �`'` q A -A 05 1 1 - - - 1 1 08 - - - - 3 3 3 3 e /d T 10 10'x 20'VIDEO TECTION ZONE „( o - - - \ TO E" gp .::ir'.::ii:i'.•:r' / A I / TOTAL 3 3 - - 4 4 9 9 \ REMOVED / -}— EVP CABLE I 1 1 2 2 2 2'". 1 DLC&S.LC, ,moo � BY S.C.E. � A B.C.R. 'I \ / 3 12 PAIR N22 1 I 1 4 / Bf- ICAMERA CABLE V��F �8 V (EXACT LOCATION BY ENGINE IN THE FIELD) GENERAL NOTES: � \ ,� \ 1 �N C \`� O 1. TRAFFIC SIGNAL WORK SHALL CONFORM TO THE PROVISIONS OF SECTION 86 OF THE MOST �a L CURRENT O STANDARD SPECIFICATIONS, THE STANDARD PLANS: BOTH PUBUSHCD BY �Ap CALTRANS, APPLICABLE CITY OF LAKE ELSINORE AND TO THE SPLCL'.L PROVISIONS FOR C 08 TRAFFIC SIGNAL AND HIGHWAY LIGHTING INSTALLATION IN THE CITY OF LAKE ELSNORE. V �A 4 2. LOCATION OF ALL UNDERGROUND UTILITIES ARE APPROXIMATE. THE CONTRACTOR 08 2" SHALL DETERMINE THE EXACT LOCATIONS AND VERIFY ALL CONDITIONS ON THE JOB SITE. C,3 DLC&PULLROPE HAND DIG FOUNDATIONS UNTIL CLEAR OF OBSTRUCTIONS. PHONE UNDERGROUND SERV':E ALERT AT 800/227-2600. o O \ �\ 3. CONTRACTOR SHALL EXERCISE EXTREME CARE TO AVOID DAMAGING EXISTING UTILITIES. 7 4. OBTAIN APPROVAL FOR EXACT EQUIPMENT LOCATIONS PRIOR TO FINAL PLACEMENT. a 2"C,3 DLC&S.I.C. 5. ALL VEHICLE INDICATIONS SHALL BE 12" WITH FULL CIRCLE VISORS, PULL BOXES SHALL BE NO. 6 AND CONDUIT SHALL BE 2" RIGID METAL EXCEPT AS SHOWN. ALL SIGNAL HEADS a Z AND HARDWARE SHALL BE METAL ALL RED, YELLOW,GREEN & PEDESTRIAN (HAND AND i Z G) CONSTRUCTION NOTES © 0/ `y1 WALKING PED) INDICATIONS SHALL BE LED. C 6. STREET NAME SIGNS SHALL BE DIAMOND GRADE VIP REFLECTIVE SHEETING, WHITE LETTERS ON n 1❑ INSTALL AN ECONOLITE TS2, ASC/2S-2100 SYSTEM CONTROLLER ASSEMBLY, COMPLETE P, \ .,h ��`-� BLUE BACKGROUND WITH CITY LOGO AND "CITY OF LAKE ELSINORE" BELOW STREET NAME. SEE N 3 W WITH DETECTION FOR 8 PHASES, COORDINATION TELEMETRY, DETECTION SENSORS, SOLO 1 �f 02 4' > SPECIAL PROVISIONS. -_ PRO VIDEO DETECTION UNIT WITH DIAL UP MODEM AUXILIARY EQUIPMENT, EMERGENCY �4` 6 m VEHICLE PRE-EMPT AND APPURTENANCES IN TYPE "P" UNPAINTED ALUMINUM CABINET. t 1 ��t �' �/ 7. INDICATES PROPOSED VIDEO DETECTION ZONE. SET TOP OF FOUNDATION AT 18"ABOVE GRADE. INSTALL BATTERY BACKUP SYSTEM (BBS) / �4�, \ `\� 8. ALL CAMERA SERVICE WIRES AND CABLES SHALL RUN CONTINUOUS FROM EACH CAMERA TO v IN AN UNPAINTED ALUMINUM CABINET MOUNTED ON SIDE OF CONTROLLER CABINET �\ �� 5 CONTROLLER CABINET UNSPLICED. PER SPECIAL PROVISIONS. AO \0 � 2❑ INSTALL 1215 AM VOLT TYPE III-CF SERVICE WITH 1AT VOLT 50 AMP METERED SIGNAL CIRCUIT, >�4 yr 5 120 VOLT 15 AMP METERED LS.N.S. CIRCUIT, SEPARATELY METERED 120 VOLT 30 AMP LIGHTING / \ / CIRCUIT AND TYPE V DELAY P.E. CONTROL FOR SIGNS AND LIGHTING. 4 0 INSTALL 3" SER`ACE CONDUIT WITH PULL ROPE INTO EDISON HAND HOLE PER SCE REQUIREMENTS. / 2 �J / /� ® INSTALL R34 SIGN ON SIGNAL MAST ARM. 5❑ INSTALL 3M MODEL 711 OPTICOM DETECTOR, 3M MODEL 138 DETECTOR CABLE AND 3M MODEL / L1 _ --- E' / \ 752 RACK MOUNTED PHASE SELECTOR EQUIPMENT. SEE DETECTOR MOUNTING DETAIL THIS SHEET. B / ,1 �\ - _ ❑ O 6 INSTALL ECONOLITE SOLO PRO CCTV CAMERA ON RIGID MOUNTING. INSTALL RG8281 COAXIAL 'I ` F 6 3 \ ,� I, CABLE IN A CONTINUOUS RUN FROM CAMERA TO SOLO PRO UNIT IN CONTROLLER CABINET. {�/ � ti� 7 \ LI INSTALL RA6 AND R96A SIGN ON SIGNAL POLE. ��, i 311 W/PULLROPE ® INSTALL 2" CONDUIT WITH 12 PAIR 22 INTERCONNECT CABLE TO MACHADO STREET CONTROLLER Cq y 8 6 2 PER SCE REQUIREMENTS ABINET (1,700' C.L. TO C.L.). TERMINATE CABLE IN CABINET AS DIRECTED BY THE ENGINEER. .9 / 2"C,2/10,2/12 \ \ 1 \ / 2'C,2 DLC&PULLROPE. 8 C) P O L E S C H E D U L E L STANDARD ARMS LUMINAIRE PED PUSH 8T. SIGNAL MOUNTING R.S.N.S. PLACEMENT O \ \ ` z q 53 C TYPE HT. SIG. LUM. H.P.S.V. TYPE RASE QUAD VEHICLE PED. MESSAGE A B / "X z ti° 10 AO 17-3-'29 30' 20' 15' 250 W B 2 N WAS,SV-1-T - • Lakeshore Or 12' 3' F \\ ! \ a B BO 1A 10' - - - - - - TV-1-T SP-1-CS - 12' 3' m \ '&? G1F N 3 © 26-4-129 30, 45' 15' 250 W - - - 3-MAS,SV-1-T Sp-1-CS • Viscoya Rd PLR AN ip' \ N \ O DO 17-3-129 30' 20' 15' 250 W B 8 E SV-2-T SP-2-CS • Lakeshore Dr P 10' \ EE 29-5-129 30, 50' 15 250 W B 8 W 2-MAS,SV-I-T SP-1-CS • Yscoya Rd 14' 3' UNDERGROUND STRUCTURES \ O 1A 10' - - - B 2 N TV-1-T SP-I-CS - 14' 3' ALL UNDERGROUND UTILITIES OR STRUCTURES REPORTED BY THE OWNER OR OTHERS AND TPOSE SHOWN \ ON THE RECORDS EXAMINED ARE INDICATED WITH THEIR APPROXIMATE LOCATION AND EXTENT.THE OWNER \ • CRY SIGN LOGO EXACT POLE LOCATIONS DETERMINED BY ENGINEER IN THE FIELD. BY ACCEPTING THESE PLANS OR PROCEEDING WITH IMPROVEMENTS PURSUANT THERETO AGREES TO ASSUME POTHOLE POLE FOUNDATION LOCATIONS PRIOR TO ORDERING POLES. LIABILITY AND TO HOLD UNDERSIGNED HARMLESS FOR ANY DAMAGES RESULTING FROM THE EXISTENCE OF \ UNDERFrJUND UTILITIES OR STRUCTURES NOT REPORTED TO THE UNDERSIGNED:NOT INDICATED ON THE \ PUBLIC RECORDS EXAMINED:THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTIUTIES OR STRUCTURES SHOWN AND ANY OTHER UTIUTIES OR STRUCTURES FOUND AT THE SITE. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE OWNERS OF THE UTIUTIES OR \ SCALE: 1 = 20' STRUCTURES CONCERNED BEFORE STARTING WORK. \ O \� 0 Z10' 20' p 40' 60' 80' EFT SEAL-ENGINEER Q BENCHMARK: TRACT 32008 SHEET NO. WORK CONTAINED WITHIN THESE PLANS$ OTE5s10 SHALL NOT COMMENCE UNTIL AN THESE PLANS HAVE BEEN REVIEWED FOR COMPLIANCE Qpe N R411 Avenida Eminas CA 92008 CITY O F LAKE ELSINORE 1 m ENCROACHMENT PERMIT AND/OR A WITH THE APPROPRIATE CONDITIONS OF DEVELOPMENT 1°1oc GRADING PERMIT HAS BEEN (ISSUED. AND/OR CITY AND STATE LAWS, AND A PERMIT �`��``SpN �9i of ano�e�D(60)9311-0664 CAN B ISS ED. P URBAN F..: (760)131-1741 TRAFFIC SIGNAL IMPROVEMENT PLAN No.52916 ti A f3 FOR / ?o e$ Exp.12/31/06 A p pAR BY: R.C.E. N0. 9 LAKESHORE DRIVE AT VISCAYA ROAD OF 2 SHTS ROBERT K. MOEHLING, ^ATY ENGINEE r DA '�i� CIVR ��� EXP. 2 1 O6 SCALE: i MARK BY DATE APPR. DATE �F pf CA\t(aF DATE: FOR: W.O..FILE N0. i3 O ENGINEER REVISIONS CITY RCE# 63056 H: 1"=40' V: 1"=40' CORMAN LEIGH COMMUNITIES 02431 CARL TON WATERS OS�19 Ga•AI.Tn..e(Ae �/olas