HomeMy WebLinkAboutTR 31920_AUGUSTA AT SUMMERLY CODE INFORMATION € w O o m PACKAGE APPLICABLE CODES, LAWS AND REGULATIONS Z<SOLAR TER PLAN PERMIT 2013 CALIFORNIA RESIDENTIAL CODE (CRC) O r° o 2013 CALIFORNIA BUILDING CODE (CBC) — ° a f° O �w g� 2013 CALIFORNIA FIRE CODE (CFC) z o = _ � 2013 CALIFORNIA ELECTRICAL CODE (CEC) V J gn ° ZD V cw v / �n AUGUSTA AT SUMMERLY ALL PV EQUIPMENT SHALL BE LISTED BY A RECOGNIZED TEST LAB. NOTIFY SERVING UTILITY BEFORE ACTIVATION OF PV SYSTEM. QppFESS/ \a�,v/ SIq�� G' PLAN 1 1 OPT . OUTDOOR ROOM 2 3 *n emawmm y* ' , , �!•�dFCTR 1Gp��Q OF CAI-\II nn I lIW TRACT # : 31920 VICINITY MAP PROJECT LOCATION LAKE ELSINORE, CALIFORNIA 92530 (D s tU M f W Li S 0- 0 0 o h f MtMM+ 0 w O (n M x LU LU 0 WOODSIDE HOMES g g ° Z) D. 0 ' < w a ~ In O 11870 PIERCE ST SUITE 250 ` ::do7Gl(• •Y�°"�• YYI i". ."y � v�i ln� Z RIVERSIDE CA 92505 Qq Lg ° � Qwo oo� ABBREVIATIONS SYMBOLS SHEET INDEX $ 1 ® At ELEC. Electrical MAX. Maximum SB Starbucks A.B. Anchor Bolt EO Electrical Outlet M.D.F. Medium Density Fiberboard S.C. Solid Core Seat Cover SOLAR ARCHITECTURAL DRAWINGS A.C.T. Acoustic Ceiling Tile E.P.B. Electrical Panel Board MECH. Mechanical SCHED. Schedule A.D. Area Drain EQ. Equol MEMB. Membrane SECT. Section ADJ. Adjacent, Adjustable EQUIP. Equipment MEZZ. Mezzanine S.E.D. See Electrical Drawings .� NEW FINISH GRADE SOLAR-AO COVER SHEET I 1 E.W.C. Electric Water Cooler MFR. Manufacturer SFD Smoke Fire Damper 2.1 A.F.F. Above Finish Floor EXIST. Existing MIN. Minimum SHT. Sheet I DRAWING NUMBER GROUP �__� FIRE STANDPIPE CABINET .\ (DRAWN ® 45') AL. Aluminum EXP. Expansion MIR. Mirror NUMBER DISCIPLINE PREFIX EXISTING GRADE SOLAR-Al PLAN 1 ELEVATION A, B, C misc. Miscellaneous SIM. Similar F.S.C. ae.5 M A.T.C. Acoustic Tile CeilingEXP.IT. Expansion Joint S.M.D. See Mechanical Drawings (SHOWN HORIZONTALLY) EXT. Exterior M.O. Masonry Opening S.M.S. Sheet Metal screw WALL HUNG CABINETS OR SOLAR-A4�A6 PLAN 1 OPT. OUTDOOR ROOM ELEVATION A, B, C Z BB. Bulletin Board MOD. Module SP Sprinkler SHELVES BE Board F.D. Floor Drain M.S. MacMouhine Screw REVISION CLOUD — ---- PROPERTY LINE SOLAR-A7^A9 PLAN 2 ELEVATION A, B, C O JL BETW. Between F.E. Fire Extinguisher S.P.D. See Plumbing Drawings � -AROUND REVISION BLKG. Blocking F.E.C. Fire Extinguisher Cabinet MTLD.. Metolted S.S. Stainless Steel A. COUNTERTOP BM. Beam F.H. Flat Head S.S.D. see Structural Drawings SOLAR-A10^�Al2 PLAN 3 ELEVATION A, B,C Cl�� i�' ,\ (N) New S.T.S. Self-Drilling, Self-Tapping �' IN' ,� B.O. Bottom Of F.H.C. Fire Hose Cabinet N.I.C. Not In Contract MATCH LINE, SHADED Sheet Metal Screw OWNER FURNISHED ITEMS - )I¢� BOT. Bottom FIN. Finish NO. Number PORTION IS THE SIDE ---- t% TOP OF WALL B.P. Backing Plate FLR. Floor NOM. Nominal Standard CONSIDERED N.I.C. (NOT IN CONTRACT) BRG. Bearing FLUOR. Face eOfent N.T.S. Not To Scale �• Steel BTWN. Between STRUCT. Structural _ F.O.S. Face Of Stud O.A.D. Overall Dimension SUSP. Suspended V-F o WORK POINT, CONTROL c•� tt CAB. Cabinet F.O.W. Face Of Wall O.C. On Center TB. Tack Board © ACCESS PANEL t TOP OF CURB CER. Ceramic F.R. Fire Resistant POINT OR DATUM POINT CH Coat Hook F.S. Full Size O.D. Outside Diameter THK. Thick C.J. Control Joint FURR. FurringOPP. Opening T.O. Top Of _ O.F. Opposite T.O.C. Top Of Concrete 0 /t.,P w Center Line FUT. Future O.F.C.I. Owner Furnished/ T.O.S. Top Of Steel 3 SECTION ? t"1 0 CL. Closet Contractor Installed TSO Telecommunication SECTION IDENTIFICATION DIMENSION LINES TOP OF PAVEMENT SOLAR STRUCTURAL DRAWINGS V GA. Gauge A3•t SHEET WHERE SECTION IS DRAWN CLG. Ceiling GALV. Galvanized O.F.O.I. Owner Furnished/ Service Outlet CLR. Clear G.B. Grab Bar Owner Installed TTD Toilet Tissue Dispenser C.M,U. Concrete Masonry Unit G.D. Garbage Disposal O.F.V.I. Owner Furnished/ TYP. Typical DETAIL SOLAR-$1 MOUNTING DETAILS COL. Column G.W.B. Gypsum Wallboard Vendor Installed �3 .--� CENTERLINE OF COLUMN / OPPORTUNITY 007542 CONIC. Concrete GYP,BD. Gypsum Wallboard O.H. Oval Head U.O.N. Unless Otherwise Noted Ay t DETAIL IDENTIFICATION OR STUD /�m OFFSET FACE SOLAR-S2 MOUNTING DETAILS&STRUCTURAL CALCULATIONS SHEET WHERE DETAIL IS DRAWN CONT. Construction O/ Over UP. Upper CONT. continuous H.B. Hose Bibb SOLAR-S3 INVISIMOUNT DATA AND SPECIFICATIONS PROJECT D-0053493 t COORD. Coordinate H.C. Hollow Core PAD Powder Actuated Device V.C.T. Vinyl Composition Tile c INTERIOR ELEVATION(S) - C.R. Cold Rolled HDWD. Hardwood PB Push Button Door Operator VEN. Veneer —}F.O.C. C.T. Ceramic Tile H.M. Hollow Metal P.LAM. Plastic Laminate VER. Verifya ELEvnnoN IDENTIFICATION FACE OF CONCRETE �//'//%/ ALIGN FACE (UNFOLD ELEVATIONS CLOCKWISE. DATE DRAWN 06-14-2016 CIR Counter HR. Hour R Property Line VEST. Vestibule B A., ND ARROWS MEANS ELEVATION CTSK. Countersink H.R. Hat Rolled PL. Plate V.I.F. Verify In Field NoT SHOWN) HT. Height PLY. Plywood V.C. Verify With Casework A SHEET WHERE ELEVATION IS DRAWN BY MMENDOZA DEL. Double PLYWO. Plywood DRAWN —{F.O.F. I DCA. Drilled Concrete Anchor I.D. Inside Diameter PT. Paint V.W.C. Vinyl Wall Covering FACE OF FINISH EXISTING WALL OR DET. Detail I.F. Inside Face P.T. Pressure Treated PARTITION TO REMAIN D.F. Drinking Fountain INS. Insulation PTD. Painted W/ With DATE CHECKED 06d4-2036 DIA. Diameter INT. Interior PTN. Partition W.C. Wall Covering \ DIM. Dimension INTER. IntermediateN P. Woad FINISH FACE TO FINISH DiSP. Dispenser iNTCM Intercom Q.T.T Quarry Tile IN Waterproof tCLF�1Rf FACE EXISTING DOOR TO REMAIN CHECKED BY EE-GeFS DN. Down QTY. Quantity W.R. Water Resistant SOLAR ELECTRICAL DRAWINGS DR. Door JAN. Janitor R. Radius W.S. Wood Screw DR. Door Side Panel JAN. Joist R. Radius WR Waste Receptacle +.+ PLUMBING OR PIPE CHASE NOT TO SCALE 'i DTL. Detail IT. Joint R.D. Roof Drain WALL (FACE OF STUD n ALIGN SOLAR-E1.1—E1.7 ELECTRICAL 3-LINE DIAGRAM &SPECIFICATIONS DWG. Drawing RE: Refer To LCB. Liquid Chalk Board READ. Required u'D'N') SOLAR-E2.1—E2.2 ELECTRICAL DETAILS SHEET LAM. Laminated (E) Existing LEV. Level RES. Resilient SOLAR-E3—E4 ELECTRICAL DATA&SPECIFICATIONS SOLAR-AU EA. Each RESIL. Resilient EIFS Exterior Insulation Finish System LT.WT. Light Weight R.H. Round Head E.J. Expansion Joint L.N. Liquid Nitrogen EL. Elevation � W � w = o h GO 9 MODULES 9 MODULES 9 MODULES3: SPR-X21-335-BLK-C-AC c SPR421-335-BLK-C-AC a SPR-X21-335-BLK-C-AC RooFAcceeERorrt TILE HOOK((S-TI RODRAccceERDr�r TILE HOOK(S-TILE TILE HOOK((S-TILE Jam, 3 a a ' INVISIMOUNT(ABOVE�LE) INVISIMOLOR(ABOVE T�LE) INVISIMOUNT(ABOVE T�LE) ( � z �u 0 a f; D "�1../ ii o z Z F < 0' � � f NCRRE T,MEROOF Z a JUNCTIM Eox M � v¢ 5 4:12 ° c) �ff JuNCnc BO:( L. 1-TION ew u " ; 0 D D 4:12 0 € 0 0 0 UTlIm AC DI9COIl1ECT 8WRCH JTIL-DISCONNECTSWRCN Ui1Lm AC DISCONNECTSWRCM FES54q`M (pR91DE GAUGE WIININ sEM, FOUTSIUE GARAGE WITHIN S UHT (01-10E G-GE WRHIN 91DNT •T F0.0M 111E MAN SFAVICE PMIELI ROMTH RVN:EPANELI FROM TN EMANSERVICEPANEL) y SERVICE POIMAIO ° D _IMM'0 0 D SERNICTM��w D 0 ° -1-E.POINT d4 Z UTIUTYMETERING 412 -- UTILITYMETERING G D D B a Sl �(�, Fp.03J11B TO ELECTRIC TOEIECTRIc TOELECTWC -NE01Y-y � /• FC.TR NGP��� urEm owD -GRID U,__ Of CA1.1�C(`,'R 3 PLAN 1 (SCHEME 2) PLAN I (SCHEME 3) PLAN 1 (SCHEME 4) Elevation A (3.02 MI) Elevation A (3.02 M) Elevation A (3.02 M) s Lu } u ^D LLu D_ U 9 MODULES 9 MODULES 9 MODULES O z 2: Q o SPR-X21-335-BLK-C-AC c SPR-X21-335-BLK-C-AC c SPR-X21-335-BLK-C-AC ONi L K Z RowwcaET+arrt . TILE HOOK FLAT TILE) ROOF,LccESD Pair TILE HOOK FLAT TILE) TILE HOOK FLAT TILE) '-I N� Lu 0 INIVISIMOUNT f ABOVE TILE) INVISIMOUNT ABOVE TILE) D,N INVISIMOUNT ABOVE TILE) (/) LYJ a D {' ", i,'= D B• ° TILE RDDF B �. 0 Z U a w COCCRETE CMCHETE nLe RDOF n�E RooF uuxCRM EDX ♦ o w .--I D D 0 4:12 ° (n z JUNCTION BO% JUNCTq INN( Q 0 0 0 D 4:12 o a 0 0 0 ♦ 0 Q w g Tll G NI 0 w .IN W $ -5 UnUTYACDISCONNECTI-TCH _ UTRITYACDISCMNECTSWIT UTILITY AC DISCONNECT SWITCH O w y� (OUTSIDE G-GE IMI SI HIN GHT j- - (OUTSOEOARAOE IWRHIN SIGHT (OUTSIDEGMMiEWTTHINSpHT- N ar ROM THE MAIN GER-E PIREL) f 1 FROMTHEMNNSERVI FE EL) FROMn1EMi11N9ERJIC-EL) C, SMICEPONTAID D 1 I<. SERVICE PdMAND ° ° 9ERWCE PBI .D ° ° ROOF"CCE9S PgxT UTIIRY METERING 4:12 J tllll UnUTY MFTEWNG UiILItt METERNGR. ° 1B ° ° TO EIECRUC DMNY ro ELECTRIC TO ELECnUC R-m.ETrx UTIITIY Gm IffILIIY MID UTILITY GRID f7 0 PLAN 1 (SCHEME 2) PLAN 1 (SCHEME 3) PLAN 1 (SCHEME 4) cn Elevation B (3.02 MI) Elevation B (3.02 M) Elevation B (3.02 kVV) Z 0 Ln _ w E 9 MODULES 9 MODULES 9 MODULES Q SPR-X21-335-BLK-C-AC o SPR-X21-335-BLK-C-AC o SPR-X21-335-BLK-C-AC a o ROOFAccE 14T TILE HOOK FLAT TILE) ITOOPI�ERONf TILE HOOK FLAT TILE) TILE HOOK FLAT TILE) ° INVISIMOUNT ABOVE TILE) '0 ° INVISIMOUNI ABOVE TILE) INVISIMOUN7 ABOVE TILE) Pal cONMETE D D .I li{_iI iT TILE ROOF i lu W w L o CONCRETE CONCRETE - � rIIE Raa a TErE Raa JU—M BOX ♦ Q 0 0 0 5:12 ° Lu �-�q� JUNcrIM EOx ''I ! JuxcnM eox OPPORTUNITY 007942 0 Q PROJECT D-0053493 5:12 k 3 DATE DRAWN 06-14-2016 0 0 0 M (OUTS EG-0xxEoNSIGHH unun nc DlECMxEcrewrrcH LU DRAWN BY MMENDOZA a FROM MAIM ICE BWXT FROMTEGARAGE WRHINSIGHT FOOMTE GAUGEF-E 91GHT FRON THE MAN BE E FOI RMIEL)NT-D FROM THE MAN SERMCEN_D FROM THE MAIN SERVICE PM'EL) - BERWCE ROMTAND D D SERVICE PoINTNID ° D SERVICE PoIxrwa ° `0 ROOF ACCESS PoRn a UTILm METERING 5:12 METERING UTILITY METERING DATE CHECKED 06-14-2016 TG ELECTRIC NN>tNT roELEcrwc RSIOMT �/ uTEm GRn unuTY DND ununo o ~�T� ,/� c CHECKED BY EE-GBFS f 3 0 yx" 1" W L O SHEET® s PLAN 1 (SCHEME 2) PLAN 1 Z(SCHEME 3) PLAN 1 (SCHEME 4) SOLAR-Al Elevation C (3.02 M) Elevation C (3.02 kV) Elevation C (3.02 M) OG � WN F w 00 m F (n aD n F 12 MODULES 12 MODULES `� y O SPR-X21-335-ELK-C-AC a SPR-X21-335-BLK-C-AC m g RooP,wcESEFOErt TILE HOOK(S-TILE)) TILE HOOK/IS-TILE 3 a O •• INV SIMOUNT(ABOVE 11LE) INV SIMOUNT(dBOVE 1E) z 0 5: B 0 D 0 o o N w R a m O W C o!F U O GOENfR.REi�E C =2 N w H n PU. ...J O BW o M a B 0 4:12 0 U kgz JUNDIIGNEO)( _ JUNGnONBO% U wM•� p ♦ 13 €S 4:12 THAE lj. 0 p ` ((-Dc DISCANNEGTSWDOH DnL—DISGONNE ITCH VppFES R EGNUGEWDHINSNJHT R�,P_ SERVIDE I F(tOM TnE 1�nnIN ServICEr ) h\!'S/ `TJTP L•3 E-TIm MMI-HING B 0 SI—CEPOINr O •.0 RooPAccEss PowT a 0 urILm METE 0 y W,03-31-18 unEim wC ~—oxMr~ Timim CNTIIC —NFE.x—F q��FCTRI�Py�* OF CAnnR&IlF�� 3 u PLAN 1 (SCHEME 3) PLAN 1 (SCHEME 4) Elevation A (4.02 M) Elevation A (4.02 M) Lu 7 W a U C m 12 MODULES 12 MODULES E Q IS SPR-X21-335-BLK-C-AC c SPR-X21-335-BLK-C-AC � w a' Z RoaFJucc Poxr TILE HOOK FLAT TILE) TILE HOOK FLAT TILE) T--� W B` O INVISIMOUNT ABOVE TILE) B B INVISIMOUNT ABOVE TILE) (/) m 5 a g > 2' 23 a w cDN J TILE ♦ Lu w JUNcnoN eox . 0 4:12 0 JOHOTN1H 800( U .....:........ 0 = N a 0 ♦ 0 _ Q 4:12 o 0 0 � (A = U UPLm AD DISOONNEOf SN'DCH UnLm AG DISCONNECTSWITCH �r G (OUTSIDE OMLWE WDNIN SIGHT I�OUTSIDE GuuGE WITHIN SIGNT FROM THE-SERVICE PgMM10 OM TM MMN SERVICE PNIEL) UTILm METERING B B RILTYMI HENG ROOFIGCE88PONT 3 m6' E ER NG �--- —F ELECTRID uO ELE—G..' unLITYGW 17 3' c PLAN 1 (SCHEME 3) PLAN 1 (SCHEME 4) N Elevation B (4.02 kW) Elevation B (4.02 k) Z 0 w 0 12 MODULES 12 MODULES ~ SPR-X21-335-BLK-C-AC a SPR-X21-335-BLK-C-AC a z RooPnccEssPOINr TILE HOOK FLAT TILE) TILE HOOK FLAT TILE) d o 0 0 INVISIMOUNT ABOVE TILE) INVISIMOUNT D O INVISIMOUNf ABOVE TILE) '� 2 �� 1lE RODE �j v' DUj W Wp CaHaETE V n ERDOF ♦ a JUNcnoN Nox ,;I:; O 5:12 0 JuH — W CTro W OPPORTUNITY 007942 LL p a p ♦ p 0 PROJECT D-0053493 E DATE DRAWN 06-14-2016 0 p M unLm�c DlscoHNEcr swncH unLm�c DlscaJNEcrswrtcN (aurSIIN G—GE wnHw slcHr �o�sTM oMMEwDHINsICHr DRAWN BY MMENDOZA ROM THE SERVN POINT AH. D 0 BERVN£PANELI p .0 OOF SGGE55 POINT S�RVIGE a umm METEwNc Pd'—MEn:aNGNc DATE CHECKED 06-14-2016 oIi unLm GRIc ~�� urluTr GRID ~Mex,rr CCC CHECKED BY EE-GBFS f TO El 3 0 yxll 1. W _ � O SHEET PLAN 1 (SCHEME 3) PLAN 1 (SCHEME 4) Z SOLAR-A2 Elevation C (4.02 k) Elevation C (4.02 kV() IS wU f 0 o rn r m m 15 MODULES 15 MODULES `" m e SPR421-335-131-K-C-AC o SPR-X21-335-BLK-C-AC ROOF—POINT TILE HOOK(S-T1LE1 TILE HOOK((S-TIIE) /�, 3 Q •• INVISIMOUNT(ABOVE TILE) INVISIMOUNT(ISBOVE TILE) / 1 z �� w cARETE 0 0 0 0 \I.J/ o M, N his To—CD. 0 ~ m N W Q O .�^i W p iaE z O =s J @ 8 i_ x n u . JUN0T10NB0X ! :' JUNCTION BO% U 0 31.1 NEL(INSIDEGARAGE) 0 su,_EL(,.SIDE_F) 0 �ppFESS/ UTILITYAC OIBCONNECIN-11 UTILITY AC DI3CONNECTSWITCN `y % S1//� (OUTSIDE GARAGE WIHIN 8N3MT IWTSIDE GNMGE WITHIN NIGHTlit} VGJ FROMTHEMMNaERWCEPANEL) T-POM TH uJELj h SERWCEPoINTAND 0 D B ,B RWFACCESa PoINT UTILITY METERING UTILITY METERING ---- EV 03-31.18 ro EEDTPoC DR�tM1'—M unury GwD uTSNY GFI '41�c OF CA`\ 3 Ou �U PLAN 1 (SCHEME 3) PLAN 1 (SCHEME 4) Elevation A (5.03 M) Elevation A (5.03 M) s W L7 J Q U t) W a- 0 o o a 15 MODULES 15 MODULES Q o SPR-X21-335-BLK-C-AC o SPR-X21-33@-BLK-C-AC rn w o' Z RooFJ SRaxr TILE HOOK FLAT TILE) TILE HOOK(Fl.AT T1LEj w w 0 INVISIMOUNT ABOVE TILE) ODNDRETE INVISIMOUNT(ABOVE TILE) (/) M O- B• r B TILE ROOF 0 B g Z Q I! �3 a g w J TILERDOF a F- L w W H H JUNCT10N Sox 0 4.12 0 Ju14cnON Sox < Q 0 Q WN Q� .JD_J 0 SVIRC G� 4t:12 gg 0 0 9UB~EL(INSIDE WRAGE) 1I.—EL 1114310E-11 x W UTILITY AC DISCONNECT H UTR1`2`DISCpNNECTSWIRYT (OUTSIDE GARME WITHIN SIGHT (OUTSIDE G=GE WITHIN SIGHT VCI FROM THE NMNSERVICEPANEL) FROM THE MAIN SERVICE FAHEL) o n�11 9ERWDE fN%M ANO B B SERVICE POINTNID B B DOF A—MI PDINT 8 mz __METERING UTILITY METERING 3: -+6 0 0 t—fINAYN—y TO ELECTRIC UTILTTYGRID =m GRID g c PLAN 1 (SCHEME 3) PLAN 1 (SCHEME 4) N Elevation B (5.03 M) Elevation B (5.03 M) Z O w a 15 MODULES 15 MODULES a SPR-X21-335-BLK-C-AC o SPR-MX2O1U-N3r-BLK-C-AC TILE HOOK T� I nKBVE�LBVINVISIMOU OE TILE) ABOVE d 0 B DONDRETE 011Lu /A u TILE ROOF RIB Vwl y y O :°E RDOF 0 0 W JUNCn014 BO% - JUNCnIXI BO% 1 OPPORTUNITY 007942 100.i W 0 0 0 PROJECT D-0063493 1:12 E DATE DRAWN 06-14-2016 auarAN¢1weIDE GAMAGE) 0 auSsuJEL(INSIDE OARAGe) p M LU DRAWN BY MMENDOZA UTILITYADARAGEN 14 SIGHT UTILITYACARkSE.—IITCH FOUTBIDE GARAGE W1.RAM.) C J� FOB OEE ANN E WW"I µl� ROM THE MMNBEIMFDNTA D / f R - 9ERV10E FaNrANo 0 0 sERvaE PoI14ruJo 0 •p ROORAGCEp roRJr UnLRY METFnwG - UTlIItt METERING ))) DATE CHECKED 06-14-2016 H u To EIECIRIC 4—GWGn� ro ELECl131C 4—°�'�°—� f(,RID CHECKED BY EE-GBFS NunLrn GRID unuTY (f 3' 0 yell 1. W � i O SHEET• Z PLAN 1 (SCHEME 3) PLAN 1 (SCHEME 4) SOLAR-A3 Elevation C (5.03 M) Elevation C (5.03 M) E€ _ . w,y w O o m r m p p 9 9 MODULES p p 9 9 MODULES y > In P SPR—X21-335—BLK—C—AC SPR—X21-335—BLK—C—AC w < m TILE HOOK((S—TILE TILE HOOK(S—TILE)) ,/ 3 a o •• ROOF,iLCESS PoIM c INVISIMOUNT(96VTE TPLE) c INVISIMOUNT(ABOVE 9LE) 0 0 p p ^ O Z (^ w &'E LL. < QOa rnERaoF C f J _ N p CONCRE E rU FrooF ♦ O p 4:12 p u JUNIMNBm( JUNC BO,t h p p 0 0 lj 0 p 49�pDFESSi v(� URLITYAD OISCOMiECf SVIRCH I.0 TIC p3CE—'-I3v�CN (OUTSIDE MAAOE YARIIN SIGNT (DUISIDE WPAGE WILHIN SWIR 2 FROM THE MAIN SERVICE PN,ELI ROM-1:SERVICE P,wELI T BERVIOE POIMMSI p p POMNJO p p N:CF.4POSlf umm METEwNG unLR�r MEIEruc p p RooF * �EQ.wai-(ey TO ELECIPoC i—[R18ES—P crttic !———S UTLRY GRID UTI E1 ,Q 3' �l PLAN 1 Opt.Outdoor Room (SCHEME 3) PLAN 1 Opt.Outdoor Room (SCHEME 4) v Elevation A (3.02 kVi) Elevation A (3.02 kW) N m (7 } 2 O a � � o 0 p 9 MODULES p p 9 MODULES N z f W SPR—X21-335—BLK—C—AC SPR—X21-335— AC—C—AC 01 w TILE HOOK(FLAT TILE) o TILE HOOK(FLAT TILE) w w f RooFwcPaNr INVISIMOUNT(ABOVE TILE) INVISIMOUNT(ABOVE TILE) cn �''� 5 a O CONCP£IE Q � 0 p p TILE RaoF p g QG � o 0 En pLn m 0 ♦ m = Q = ,uNcnDN smc ,uNCTroFJ eox U O 0 Jp a g o p ♦ p N N O 4:12rn" N Z 0 0 o �� g umm,LC DIscoNNEcrswnw ummnD DlscoNe�crswcc o m� (OUtSTHEW N EN'IMIN MGNf FROM THED NSI VIRH NSMM O FRdA THE MMN SERVICE AND 0 0 �" ) 0 0 �+ SERVICE PgNTM1D UTLRY METFRSp InILRV MET3iniG �CCE33 PONT m 0 y 0 V m TO ELECTRIC E—RF„wr—S E'—��_S G unLmawo unLm 3' a c PLAN 1 Opt.Outdoor Room (SCHEME 3) PLAN 1 Opt.Outdoor Room (SCHEME 4) v1 Elevation B (3.02 kV,) Elevation B (3.02 kV) Z O 1n w P 5l 9 MODULES P R] 9 MODULES F 0 SPR—X21-335(—BLK—C—AC 0 SPR—X21-335—BLK—C—AC Q TILE LAT 0 INVIS MOUNT(ABOVE TILE) m INVISIMOUNT f ABOVE TILE) d RooF ass PoMr N � o p `R ° ° W C� DONCREIE V m nlE RooF Q s LU B 5 p c OPPORTUNITY 007942 ,urvcnDN Eon JuxcnoN eox LL 0 p W PROJECT D-0053493 .6 ♦ 0_ ° 5:12 ° 3 DATE DRAWN 06-14-2016 M 0 p LU DRAWN BY MMENDOZA unurr,,c DlscaxJEcrsvnra FC Dlscox xrswRDx (p?SMIE GOUGE YIIMIN BNR? FRD SOFDMSGE WIT SGIR FROM TIE MNN 9ERVN£PRNEL� ROM T, E FN ) i,nLm MEiPmiG ° p ° waCE METERnc ° D ° ROOF RCCESSPoINT „_J, DATE CHECKED 06-14-2016 CHECKED BY EE-GBFS m EIE RNm—s �—w,eErc—s l unuTr—GwD LIWGRU 0 O SHEEr Z PLAN 1 Opt.Outdoor Room (SCHEME 3) PLAN 1 Opt.Outdoor Room (SCHEME 4) SOLAR-A4 Elevation C (3.02 kV� Elevation C (3.02 YW) E� x '$ wo p 12 MODULES P 9 m N m m D 0 p p 12 MODULES a SPR-X21-335-BLK-C-AC > o � SPR-X21-335-BLK-C-AC a TILE HOOK((S-TILE TILE HOOK(S-TIL 3 a m a RooF AccEss POINT INVISIMOUNT(dBOVE 1�LE) INMSIMOUNT(ABOVE qLE) z U o 0 p D D F 0 z Z cmDRETE a o o M, FILE ROOF w C a COiENa a x x J a3N ° o u �O 4:72 D 0 a auxcnoH Sox JUNDTON— ♦ V, D ° 4:12 L ° lj e B Q(��QppFESS/ FOUTSIDEDDGM%GE MNECTN TCH!I UTILITYACDISCONxECT 1— SCR^_ FOUTEDEG—GEWHHINSIGHI' FROM rH ANEL� ° 0 FROM THE MAIN SUTIERVICE—) 0 0 i y A CE PoINETFRxG UHLRY RWCnPoIE� ROOF ACCESS POINT p p EmcRuc —mw.n� 9 �FCTR\�P \Q' -TIE GRID u°unc cO OF 3' PLAN 1 Opt.Outdoor Room (SCHEME 3) PLAN 1 Opt.Outdoor Room (SCHEME 4) v Elevation A (4.02 kV) Elevation A (4.02 kW) N m ON w d � o a ~ LLJ a p 12 MODULES O �r lJJ B 0 p p '� 12 MODULES N w l JI SPR-X21-335-BLK-C-AC SPR-X21-335-BLK-C-AC OI TILE HOOK FLAT TILE) TILE HOOK FLAT TILE) T•H W 2: ROOF AGCI—POINT INVISIMOUNT ABOVE TILE) INVISIMOUNT ABOVE TILE) (n M 5 a O O a 0 � � � o 0 n�RGDF ♦ Ln 1 N o 4:12 ° - - Z) f O GNGTIDNRDA ,GNGTID„xD>< D �� ° Q ° 0o N O J' E z D p 0 �g g o �o a Off—oNNEcr svRCH TTYAc DIECONNEcrswNCH o FOUTSIDE GAMGE wNHIN SIGNi (0 p w ROM TIi AIN SERVICE PMlEL) FOUTSIDEG—GEWITHINSIGHT O E MSurtv MOINN ND 0 p ROM THE SEWCEEPOINTAND m IN SERNICE � G ETERING AGGESS POINT B p p TO RND R—• DTILITYGRI °Emo 0 3' 0 PLAN 1 Opt.Outdoor Room (SCHEME 3) PLAN 1 Opt.Outdoor Room (SCHEME 4) N Elevation B (4.02 kV) Elevation B (4.02 kW) z O N w 2 p 12 MODULES IP `a 12 MODULES H B SPR-X21-335-BLK-C-AC B SPR-X21-335-BLK-C-AC TILE HOOK RAT TILE) TILE HOOK FLAT TILE) d o o INVISIMOUNT ABOVE TILE) o INVISIMOUNT ABOVE TILE) RODE AccEss POINTy B ° CONCRETETILE ROOF 0 ° W y V o coNCRETE V > TILE ROGF Q w p c OPPORTUNITY 007942 XICTlON-- - JUNGnONROA LL 0 PROJECT D-0053493 ° 5:12 DATE DRAWN 06-14-2016 e _NECT_ 0 DRAWN BY MMENDOZA _ (O MITOHEG—GEMOTHINIOGHT (O—DEG EWITHIswRCH SERce PoINrN o) 0 p FDau ITMEDiunl�e�nI DE aGiwE) Q UTILITY METEwNc R uTILITYM=G ° LI ° DFADOESGPoINT ,�_ DATE CHECKED 06-14-2016 ELEcrRIc TO ECTRI CHECKED BY EE-GBFS UTIL ITY GRIDGRID 0 W � O SHEET6 PLAN 1 Opt.Outdoor Room SCHEME 3 PLAN 1 O t.Outdoor Room - - ( ) p (SCHEME 4) SOLAR-A5 Elevation C (4.02 kW) Elevation C (4.02 kV) Ec x DO o m p p 15 MODULES p p 15 MODULES SPR-X21-335-BLK-C-AC SPR-X21-335-BLK-C-AC m a TILE HOOK(S-TILE TILE HOOK S-TILE 3 a s Roof ACCESS PaNr o INVISIMOUNT(ABOVE T�LE) o INVISIMOUNT(BOVE LE) z o at =oP, 0 O v w 0 0 0 0 yn� r O z G+ Z a=F cN Ro�aE LL• a DO W TILE O m x o;W C.HOOF g 4:12 0 +unm,ax eox - = JUN— B p �pFESS/ suBpANELONSIcecARAGE� sus-PANELDNSIDEGARACE) Tr nc DlscoNNEcrswrrcH unuTV AC DIScoNNEcrsv— Four51DE R—E WRHIN SIGNr FO_IDE GARAGE WRHIN SIGM 4 ROM THE euw SERVICE PAxeL) FROM THE MAIN SER E'PANE) SERVICE POINTAND B B SERVICE POINTAxD B B COF ACCESS POINT nLD ME ERING a GTILI YME ERING e * EV.0331 FCTA%" �? u ID o E—C E.— �—Dv.EMr—i �OF(y1lN� GR UNL I o S I lL l PLAN 1 Opt.Outdoor Room (SCHEME 3) PLAN 1 Opt.Outdoor Room (SCHEME 4) v Elevation A (5.03 M) Elevation A (5.03 M) m s Wd U � o aQ W a 0 H w IT I p p 15 MODULES p p 15 MODULES fV0 f W SPR-X21-335-BLK-C-AC SPR-X21-335-BLK-C-AC a1 w W TILE HOOK FLAT TILE) c TILE HOOK MT TILE) ROOEACCESSPOINT o INVISIMOUNT ABOVE TILE) INVISIMOUNT ABOVE TILE) f7 S O_ O ;,°EGR #k z K 0 D RGGE p p Qb a. ° w ° TILE ROOF ♦ U) N ° ... .::... p 4:12 B = Q JUNCTIONBDx - JUNCTRASOX (D E ° ♦ a gO B 4:12 m � N —, i N°� Z B B $ s g Ow Su EL(INSIDE GARAGE) sus-P�NEL(INSIDE—GE) o -H o a a-PAN m JTL1 TYACDISCONNECTeWRCN O o FoUTEIDE GAMGE WRHIN NENT (O—DE DGARAGEWRNINSIGHT- OO FROM THE MAIN SERVID—.) ROM TR MAIN SEwnCE PAxEt� ; .� B B E SERVICEPOINTAND B B OPACCESSPOINT UTILRY METERING UTILITY METERING m e e � m unLRr Gw umrtv GRID 3' J a 0 PLAN 1 Opt.Outdoor Room (SCHEME 3) PLAN 1 Opt.Outdoor Room (SCHEME 4) cn Elevation B (5.03 kV/) Elevation B (5.03 kV Z O w 2 � P Sl 15 MODULES P q 15 MODULES B SPR-X21-335-BLK-C-AC B SPR-X21-335-BLK-C-ACTILE Q m INVISIMOUNT ABOVE TILE) o INVISIMOOUONT�ABOVEI TILE) �/d RoOE ACCESS Poai1 U N a• B co�cREre 0 0 W GGE U o C) > �RaGE a LU 512 B m OPPORTUNITY 007942 JUNCTION BOX JUNGnoN BOX a 0 W PROJECT D-0053493 0 5:12 DATE DRAWN 06-14-2016 M suB.P,wEL(INSIDE GuucE� p suBnANEL(INSIDEG—GE)) p NW DRAWN BY MMENDOZA ITI L7. FOUTSIDED DGARAGE WRHIN SIGHT OUTSIDE GMAGE WRRIN SIGIR FROM TR SEnWCE PANELI FROM TR—N SErrvICE PAxEzI Q E SERVICE POINT— B 0 E SERVICEPGINTAND 0 0 OI ACCESS POINT y� DATE CHECKED 06-14-2016 LTnury METERING UTILITY METERINGILL ✓ _ R CHECKED BY EE-GBFS mIc owT.�' To ELECTRIC uDLRV GRID _FYGRI DTF W L O SHEETM Z PLAN 1 Opt.Outdoor Room (SCHEME 3) PLAN 1 Opt.Outdoor Room (SCHEME 4) SOLAR-A6 - — Elevation C (5.03 M) Elevation C (5.03 M) zr be 3' m m o pg� 9 MODULES 9 MODULES SPR-X21-335-BLK-C-AC ---T— SPR-X21-335-BLK-C-AC TILE HOOK�(S-TILE) ) ' TILE HOOK�(S-TILEI ) L INVISIMOUNT lA4BOVE TILE) 1 I INVISIMOUNT AABBOVE T LE (arJ. z m o ID I Ip � - ooF nccEss PaNr ~ O z h JUNcrioN Box z Q m O rRE Roof ✓ R } K Q Y •� Hs : O = o o3x JUN—M � O 4:12 -- nLE Roof 'o RODE nca:ss PaNr 0 D e D swNNEcrswDal o J ILITYNC 1—NECrswDC14 S/,?Qti curslDe c:w.xre wDNw siGxr p coursioE GuuGEvmmws�cNr 0 ti / 'Y� oM THE MUN SIr0I P%'=j ROM THE M/JN smncE Pu�Ey 5�R/ SERVICE—N-13 R RWCE PaN—D r, CTI MEIEWNG UTiLRY METERING Y E+P.m31-18 F�FCTR unun-D '—°r' —' unLrrvcwDC tlA41M1'—' rFOF�II I�IIVnn l lW PLAN 2 (SCHEME 1) PLAN 2 (SCHEME 2) Elevation A (3.02 kV) Elevation A (3.02 kV) s w z J W a U a. ~i m 0 9 MODULES 3 3 9 MODULES n1 in Q r-------T---- SPR-X21-335-BLK-C-AC —T-- SPR-X21-335-BLK-C-AC w d' Z `T'� TILE HODK FLAT TILE) i TILE HOOK FLAT TILE) "'1 Y W O p 10 INVISIMOUNT ABOVE TILE) 0 I INVISIMOUNT ABOVE TILE) (n M 5 a F- = c JUNII—B>< o y, RODErccEss POiNr a J E RDD Q Lu L LU N 4:12 k _ Ln � H JuxcnoN Box V) Z g a a Ro T - N _ 4:12 I n°E aooE Q k RGOF PONT ti O 0 0 0 N u = �w o �❑ urwTYNC 1-14 Ecr 1— FRo, UraRYA1=.1NECTSWOCR o 60 (CUT D u=ixN sERv�e EIGI - 0 FrJRursmE G.R..cE wrrHiN s�cHr p s u�LCTT M NiEwµiuc GM rHE MUN WEnuicE NT-' 0 TII u"L,. .NG 3 m u U C nL".IB t—oR.vx—� TIDILY Grz Q PLAN 2 (SCHEME 1) PLAN 2 (SCHEME 2) cn Elevation B (3.02 kV;) Elevation B (3.02 kV� Z O 1n LU 3 3 Q 9 MODULES 9 MODULES SPR-X21-335-BLK-C-AC --- --- SPR-X21-335-BLK-C-AC d o TILE HOOK FLAT TILE) L' i TILE HOOK FLAT TILE) INVISIMOUNT ABOVE TILE) 0 INVISIMOUNT ABOVE TILE) U) IE W TILE ti 0 0 o JUNCTID14 — - - I-F—ESEPOINT JUNITIINB- V a M Q 5:12 - - - - - - W ROOEVTurr - - - - -- OPPORTUNITY 007942 RELourEo e coxcRErE W TO BE PROJECT D-0053493 5 B TILE RODE 0 RDOF—Ess PoiNr 0 DATE DRAWN 06-14-2016 nc OiE-NNECTSWircH 3' Urarrvr.CDISCONxec E—H (OIIT IB E—GEWITHINBIGM O FOUTSIDE E—E WTmIN EIGHT p DRAWN BY MMENDOZA FRDM TiEMNNEERVICEPI 1 ROM WNSE—CEI—EL7 IcEwD .G u M uraDMN DATE CHECKED 06-14-2016 o - o o ✓J unLrrc E.— F-°B'DNT CHECKED BY EE-GBFS GRl 0 T/„ 1„ W L� O SHEET Z PLAN 2 (SCHEME 1) PLAN 2 (SCHEME 2) SOLAR'A7 Elevation C (3.02 kV,� Elevation C (3.02 kW) DC x � W 3 3' IpA m m € 12 MODULES 12 MODULES 12 MODULES lA a Moi o F SPR-X21-335-BLK-C-AC SPR-X21-335-BLK-C-AC SPR-X21-335-BLK-C-AC TILE HOOK,(S-TIL VENT TILE HOOK(S-TILEI TILE HOOK(S-TILEI /�� 0 0 INVISIMOUNT(ABOVE LE) roeE INVISIMOUNT(ABOVE TILE) INVISIMOUNT(ABOVE TILE) ] SPLIT RRAY RELowrm 0 n 'FMB/0 B SPLIT RRAY p 10 MODULES ooNCRErE r C)Z u+ _ 11 ale RooF JuNcnarJ eox ROOFAOOE9E POE1r RooF o -e Ea coNCRETE 10 MODULES r Z a x w a JUNOTNIN emcOVP.) p U ff p a j; - - O O O ROOFVFHT Y LOG1D �..I 4ilF ;f + RELDGTD ;. JUXCnOX 90X(tVP,) � �S 4:12 TILE ROOF ROOF AOCE93 FOINT €p ROOF I�CCEEEPoM ROOF nccEae PolNr .120 n B77 B B `o UTER/AC OIECONrEOraWROH , j� 2MDDULES UTIurYK018OONXECraWOON(W18E) N JEWRNNB B Roo (OUraIDE YNMOEWOHIN MGM B UTILITY -1 Fc— N FqME�ANL) 0 3'm —Na) FMNEA _ 2 MODULES B unuwPONTNJD 9LTILIT. N. 9ER LITYMINTNO ^ y UnuTY ME1EPoH0 UTILITY MfiElUNO UTILTY METERING ilaj em.m31-18 TOE.— E.ORE) MnaRr TO mclmc IJronLErt�r oRlo oNaMr �y��FC TR\�P��a�* OF MAIL. I PLAN 2 (SCHEME 1&3) PLAN 2 (SCHEME 2) PLAN 2 (SCHEME 4&1) Elevation A (4.02 M) Elevation A (4.02 W) Elevation A (4.02 M) w � s � Q U W a m 12 MODULES 3 3 12 MODULES ry = f Q 12 MODULES SPR-X21-335-BLK-C-AC ISPR-X21-335-BLK-C-AC SPR-X21-335-BLK-C-AC Of TILE HOOK(FLAT TILE) RODF VENT TILE HOOK FLAT TILE) TILE HOOK(FLAT TILE) .--) ,D�j w 0 INVISIMOUNTA(ABOVE TILE) roEE INVISIMOUNT ABOVE TILE) INVISIMOUNT(ABOVE TILE (n tm d t-I e e SPLIT RRAY RE—En D II 0 0 SPLIT RRAY Z * 10 MODULES ; —RETEE JUNcnaN eox d ROOFAOCE9E PoRJT me ROOF m O C W rile RaoF � J 10 MODULES i Q W w LU JUNOTON RooF�ENr U) ? BOIL ITYPJ C O O O O. p c g RELOCRTED - _ JUNCTION BD%01.) REI.DDJ„FO � a 4:12 rnoNCRETE Q g LE ROOF ROOF•CCE99 PoINi ROOF—PoNT D ROOF PoINf 120 0 o UTILITYAOOMICO.EcrawRCH 2 MODULES ..o j (oml�c DIacoFrEc1.PnrcH B UnUTYAc OIacoNNECiawnCll w (auraoE DNUDEmmIxanNr p Fouralce ouuDE wIrNIN woHr FRaM mE MNN sEJNR:E PJNELI RooF,�ccEea Polar ROM mE MNN sERWce PNELI ) BERWOE PoNr NJD sERYICE PoINr NJD vRoMm a�RNzemcE vauJa 0 2 MODULES s—IT MET RING ti unlm MEroENo unuTr MEn=wrJo unim METERING 3• ; 8 %IFcmlc MNOMr TOimclwc EINTJNr —awo 0 0 PLAN 2 (SCHEME 1&3) PLAN 2 (SCHEME 2) PLAN 2 (SCHEME 4&1) Elevation B (4.02 M) Elevation B (4.02 M) Elevation B (4.02 M) Z O En w e 3' 3' d 12 MODULES 12 MODULES SPR-X21-335-BLK-C-AC -- SPR-X21-335-BLK-C-AC Q `T T FLT TILE) TILE HOOK FLAT TI ) d C,INVILE HOOK A SIMOUNT((ABOVE TILE) INVISIMOUNT ABOVE TIIELE ) 0 0 SPLIT ARRAY 0 N TEe RaoF 6 MODULES JUNCTION IRA ROOFRCCE3E _ � * �3 JuxclarJ eoz(rrP.l - 5:12 I 11 121 RODFkerlf - - roeE o OPPORTUNITY 007942 coNCREre Q PROJECT D-0053493 ROOF ACCEA9FgM �1 D rnE aooF _ aoaF�ccEsa PONr 0 _ 0 DATE DRAWN 06-14-2016 6 MODULES M unLm�c macoNNEcrawlrcN d 3' W DRAWN BY MMENDOZA (cu.RiI—EWRHNBFJMT O (OUrBIDE WUOEWRNIN&OM /��// FROM mE MNN aERVICE PNEL) FROMnIEMNNaERNIOEPNEJJ B LL 9ENVIOEPoI— BERVIOE FONTNlD UTILITY METERNM3 UTILT'METERNO ����;; DATE CHECKED 06-14-2016 unllrvawD p1Ad'' T1 11 wlo ~oM.vN� %f, CHECKED BY EE-GBFS (f D V 1^ W � G SHEET M PLAN 2 (SCHEME 1) PLAN 2 (SCHEME 2) Z SOLAR-A8 Elevation C (4.02 M) Elevation C (4.02 M) W � � F 3' 3' � v�imNw 15 MODULES r v —T---� SPR—X21-335—BLK—C—AC N < O1 m TILE HOOK((S—TIL 3 aEli x�FTO� INVISIMOUNT(ABOVE 9LE) 2 ?Q N N a x owm w xoosnccEsa romm a m 0 w 5 JurvcriOry eox o O s u �og ° B sOsa�wEcorvs�OEO.x�OE� ��/ u<l­­ bq.w3J-ia TO— cxo �OF rnu l� PLAN 2 (SCHEME 2) Elevation A (5.03 M) w s O W u a m 3' 3' 15 MODULES O i ~ SPR—X21-335—BLK—C—AC ONi Q TILE HOOK(FLAT TILE) w MJ C)INVISIMOUNT(ABOVE TILE) (n (`'1 g a �r xoas access rarvr Q g > a Lu J urv�«xo ga w LU V) ~ u~i z a o o U g + Q N ga 4:12 corvcxere nee xaoE O ° t;go (n sueP�rvE<.�rv��E ,- w s 0 0 0 oo ^� ­­G 3 m m �xo 0 0 PLAN 2 (SCHEME 2) N Elevation B (5.03 k) z O cn w 15 MODULES 15 MODULES Q SPR—X21-335_BILK—C—AC — SPR—X21-335—BLK—C—AC z TILE HOOK(FLAT TILE) T i TILE HOOK FLAT TILE) a 0 0 INVISIMOULN�T(AABBOOVE TILE) i° INVISIMOUNT ABOVE TRE)SPRY N wrvcAE�E A y t� n�xooE W w 6 MODULES Jurvcnory saz -aooE AccEss rOirvr 5:12 - - - - - W roeE xE oa m OPPORTUNffY 007942 o W PROJECT D-0053493 aaas�xemEawr ° -n��a �_ F. xaov J�ccEss Eomm ° 0 DATE DRAWN 06-14-2016 9U6PANEL(MBGEt31RMiE) 9 MODULES 9Ue-0M'EL QNMOEGW E) M W unurv�caxoxrvEcrswrta d UnuTYAt Oiscorvra:cr svnrcry � DRAWN BY MMENDOZA i 3' (OUI810E wa�Oewrmwsx;xr 0 (oursice cOUOEvmmiry srvaJr 0 �i moMnE ww aexwce rvrEU vxeM ixE wux sExvx�nJwa� SERVICE PoIMMlO $FRVICE roWr Nl� Q UnL11Y MEn3UN0 Unllry NERFNG 7r DATE CHECKED 06-14-2016 o ro E�Ecmw owv y ro E�Ecmic CHECKED BY EE-GBFS TOEn O TO cw0 J, H O SHEEr PLAN 2 (SCHEME 1) PLAN 2 (SCHEME 2) Z SOLAR-A9 Elevation C (5.03 kVlo Elevation C (5.03 MD LJJ N ~ o m u�m o oil 9 MODULES 9 MODULES } y v+ Y SPR-X21-335-BLK-C-AC SPR-X21-335-BLK-C-AC m < m m TILE HOOK(S-TILE) TILE HOOK rS-TILE) yY'�, 3 a •• INVISIMOUNT(ABOVE TILE) INVISIMOUNT(ABOVE TILE) 11 I z u o a o �3 F.11 0 o m, I gEr j $ROOFACCE—NT L 7 o Q= v ROOFVENf Ip' M J G = auxcnoN w>< 412 —MATED - - -I�"- � O u duNCTDN eox 0 u �qp� COHCPETE � �Q TlE ROOF 4a2 0 0 0 0 �ppfESS/pU, �I S/q/ 'l umm�c—NEC EWIrcH (.u. wx EWITI S-T / (WTEId:ONUOE WTMINENNT RO�-CCE98 PdNT FO TH O4UOE WITHIN BDHT y 22 HROM THEI 8E—EDEPMI¢I RgITHE NWIH BBMOEPNIK) T BERYICE PgNTND ROOF VENT SERVICE METE— ururvHETERPD � RELoun:D urluTr HETEwxc 0 Em.OTST-1E q fCTR To EIECIRIC 4—pRtna' ro EIEc Qc(y\L\ ummolao ug--D III PLAN 3 (SCHEME 1) PLAN 3 (SCHEME 2) Elevation A (3.02 W) Elevation A (3.02 M) s Lu } s U 3 3 W d m 9 MODULES 9 MODULES O _ a SPR-X21-335-BLK-C-AC SPR-X21-335-BLK-C-AC w W Z TILE HOOK FLAT TILE) TILE HOOK(FLAT TILE) x a 0 �j INVISIMOUNT ABOVE TILE) 3 INVISIMOUNT(ABOVE TILE) US en 5 �+ a Q TuxcrlaH Eox a Ea n1ERODP �e o RaoFAccEESPorrt �j d J Cc H to JUNDnDH Ewt a:tz ..;I = a Z no Ew�rE a RDDF ROOF ACCE9B POINT Ul UI N (n = U� _ w W 0 3• —olecoreEcreWITcH ummnc DRDoraEcravrticll FOUTEIDE—E—N9DHT FOUIEDETYJUOE WffMN9NRR 8 m ROM THE LIEN 9ERVDE PINEL) RON THE—H E0IVICE PNI¢I 3 EERVIOE-NT— D 8¢IVNEP TNO B UIEITY HETERMO UTILm METE— m U 0) TO Eiwmo -OTv—� roEIECIRIO �'-OIIL-T!--� uTILITT awD unLm wao a 0 PLAN 3 (SCHEME 1) PLAN 3 (SCHEME 2) 1n Elevation B (3.02 M) Elevation B (3.02 M) Z O to 3' 3' MJ 9 MODULES ___-----—_ 9 MODULES Q _ 5' SPR-X21-335-BLK-C-AC SPR-X21-335-BLK-C-AC o TILE HOOK FLAT TILE) TILE HOOK FLAT TILE) d INVISIMOUNT ABOVE TILE) INVISIMOUNT ABOVE TILE) E J B Lu o e n R .DHCTIDN Rox f a RooF—MNT V ?o 5:12 n Lu 0 0: JuNCTDN OPPORTUNITY 007942 QPROJECT D-0053493 ROOF SEE POFR R o 3 DATE DRAWN 06-14-2016 0JO 0 0 M3WDRAWN BY MMENDOZA (�OWTE—Sfi—E BDHTF1=T—HWRNOEWITIIFIOM THE AWNBERVDE PMB) ROH TH IMIH9ERVDE PNI¢) D0 EPOM' DATE CHECKED 06-14-2016 urlLm HETEwx CHECKED BY EE-GBFS ro ELEcmD �—Hnan—� ro ELEcmD �—aRuw—a. i' umm aRD unLm ORD 0 54• 1^ W L� O SHEET6 Z PLAN 3 (SCHEME 1) PLAN 3 (SCHEME 2) SOLAR-A10 Elevation C (3.02 M) Elevation C (3.02 M) �G x 0 e w O o rn r VI aD G m 12 MODULES 12 MODULES �P SPR—X21-335—BLK—C—AC �P , SPR—X21-335—BLK—C—AC i TILE HOOK((S—TILE ; TILE HOOK((S—TILE 3 a o INVISIMOUNT(IiBOVE T�LE) I IC INVISIMOUNT(LOVE T�LE) i �� 0 I D O wxcREn: � r 0 2 Z 5c s a n(e RDaP RaoP�ccEss POINr � �O �w p vENr J Ysi O euxcnox awc 4:12 "' xELor.TO."o- _ _ _ O o uNCn— D RDDP (� lam c 4:12 B B D 0 urlutt.co'xoNxEoraw°cx B unutt nc ascoxxPcrsw�ra� D ti'\ p (OOnxDEONNOE WD11x191GM ROOF IOCE53 PqM (POO 11 ON-wOHm'r.) h . FROMl1E L1NN 9ERNCE PNVaI 1iOM 1NE MNx SERJILE PNV¢) (7 BERNOE POINT M10 B ROOF VENT UfILItt METERING B � > UIILm METERING roEE ro EIEOIRIO �—DTflNl—� To¢Ec�Rc �—oRrtrwr—a ��fCTR\OPa\Q' . umm cRo unLm cw �` Q�CAI II PLAN 3 (SCHEME 1) PLAN 3 (SCHEME 2) Elevation A (4.02 M) Elevation A (4.02 kV� s Lu J U � Q U 3' 3' Wi2 CIO d 12 MODULES ------ 12 MODULES ry a P SPR—X21-335—BLK—C—AC I SPR—X21-335—BLK—C—AC Ol 02 Z TILE HOOK FLAT TILE) TILE HOOK FLAT TILE) 14 W O INVISIMOUNT ABOVE TILE) , INVISIMOUNT ABOVE TILE) (n fn 5 O. i e i I j a g > Dx xD IL e Ti— •°x°„ �= Roos—PaNr LU W .uNcnoN scut 4:12 lL M ) N Z o c9 g RaoP lccess POlNr 4:12 En V) o �^g x V UTILm AO OIBOONNECI'8WRC11 D 3 UIILm AO DISOONIFCf SKnfJ� D o y' IDOTBOE°uM°E 4xf1lIR1810lII FOOISIDE GNYWEKInllx 91G1n PnoMIrEMUNeErrvICEP,w¢) ROM TN M,MNSERVIGEPy 3 EE—EPdNTNVD B E SERVILE POMIND D UnIITV MEIBUNG DnlnY NEfBMG m U m unLmcRw unLmc a 0 PLAN 3 (SCHEME 1) PLAN 3 (SCHEME 2) N Elevation B (4.02 k) Elevation B (4.02 M) Z O M Py 3. 3. W 12 MODULES 12 MODULES Q ��—_-- z SPR—X21-335—BLK—C—AC F SPR—X21-335—BLK—C—AC O TILE HOOK FLAT TILE) TILE HOOK FLAT TILE) d INASIMOUNT ABOVE TILE) i INVISIMOUNT ABOVE TILE) N e I D W w o e n�aaoP .IuxcTN»t eoz o o Roof•ccEss PgNr C� 5:12 W o auxcnoN eox OPPORTUNITY 007942 _ o F RooP,�ccEas POINT aaaP 0 PROIECT D-0053493 e DATE DRAWN 06-14-2016 I 0 e D D CLM - 3 LU DRAWN BY MMENDOZA unulv�c ascaxraEcrs✓/rtcH urrnc DlscoxxEcrswNLn (OUTBnE OxRnOE WfINN SIDHT FOUISIOE GNUGE W1I111H SIGM FltOM THE MAIN BEINICE PIN¢) ROM THE MNx ServICE PNs.L) Eimuir—rlEielrc 0 0 uti¢wµ°c D 0 ,_ DATE CHECKED 06-14-2016 ro ELECIRIO �--Dkwr—i ro E(ccrluc s—-aa—� %/, CHECKED BY EE-GBFS unLmawo unLmcRo f 0 Y2" 1" W _ H Q SHEETo PLAN 3 (SCHEME 1) PLAN 3 (SCHEME 2) Z SOLAR-Al 1 Elevation C (4.02 M) Elevation C (4.02 k) �a _ a LJJ IA � F. 11 MODULES w N 0 o moil 15 MODULES ------ 15 MODULES _—_ _ 15 MODULES ------- 15 MODULES a a N o l P SPR-X21-335-BLK-C-AC P SPR-X21-335-BLK-C-AC P SPR-X21-335-BLK-C-AC SPR-X21-335-BLK-C-AC TILE HOOK(S-TILE) TILE HOOK rS-TILE) TILE HOOK(S-TILE1 TILE HOOK(S-TILE 3 a o a x INVISIMOUNT(ABOVE TILE) INVISIMOUNT(ABOVE TILE) INVISIMOUNT(ABOVE TILE) INVISIMOUNT(ABOVE T�LE) z u o a B 3 SPLIT ARRAY SPLIT RAY B SPLIT RAY TItE 0 $3 SPLIT RAY o O Z a w B 5 0 5 M mlip caE o co p o^i W 4 MODULES RoaF AccEESPorrt 7 i 4 I RooF AccESEPORJr 11 MODULES 4 MODULES a = v al RooFro I 1 121 Roa vTaJr �12 12)POOFVENTeox(rvP.) 4:12 I� RELxmcwo 4 LTO�orwTED o u u JUNCTION Bozlm.l euNcnoN EoxlTrP.) 0 p 4 MODULES JDN Eoz IIYP.) � nErmDF _ [/� T°T911 fl00FACCE83 PoW! T + ROOF ACCESS PoIxf ra 4:12 RaoF AccEe3 PoRJr RooF AccEe3 Powr 4 MODULES 0 0 it MODULES 0 0 0 0 BYN1 0 816PAx¢IINSIOE DAJM.DE) 0 MIBPAN¢IRJSIDEOWAE) B 8U&PMI¢IINSIDEOMME) B SUEl11NSIOEOMN3El 0 UHcn Y>` SIA/yl,y IREm AC pSCOHJECTSWfTCH lEIfYAC OISCDHTECT SWITCH UTEm AC ONICpNECT BWRCH UTI-A4DISCONNECT—H IWTEnE ONUOE WTfHdBNNR ROOFAdYE83 Pdxr (OVISIOE—1WOWN BNiHr FOUTSIDEO EWRHINSNM (OMIDE TMIiWE-HIN BIGHT RODE ACCE39 ' -THEMMNSERVICE PMJEL) FRpA THE MAIN BERVCE PAN¢) qdl THE-SERVICE PAN¢I FROM THE--.BERVCE PANEL) BENVICE fgINTAND 0 E TOROOF VENT BERVCE PoNRAJn B 9ETTI POINTAWO B BERVICE PDMAJC B UTILITY MEIERINO TO.�A� ummMETERrxi ummMETERwo urILm ME�EIu"° 11 MODULES oR.waT-Te 9��FMCTnnR��\OPT�* TOEIECIRIC -� TOEII:CTPIC �-MRdRI TO ELECTRIC �-mm OELEC-C Url-diC �- UTILm ORC Un-DRC UTILm GRID PLAN 3 (SCHEME 1&3) PLAN 3 (SCHEME 2&4) PLAN 3 (SCHEME 3&2) PLAN 3 (SCHEME 4&1) Elevation A (5.03 M) Elevation A (5.03 M) Elevation A (5.03 kW) Elevation A (5.03 M) s w } 3' 3' Lu Lu udl' a m L O z ~ 15 MODULES -- 15 MODULES N Q P SPR-X21-335-BLK-C-AC P SPR-X21-335-BLK-C-AC 01 w DC z TILE HOOK FLAT TILE) TILE HOOK FLAT TILE)TILE) M 5 a O�-A INVISIMOUNT ABOVE TILE) �, INVISIMOUNT ABOVE r 0 0 z Q Q 5 > JUNcnm SOA UJ 0 0 Ira o ROO—ESSPORJT a J 0� Lu LU CTION BOX 4:12 _ _ M � JUN u~i z o o C9 f g CONCRETE D N 0. nLE ROOF Q 4:12 u O flooF AccEss PoZJr o �g = U K�yOj .—EL INSOE—E) 0 3 SU—EL(INSIDE DAJMMJaE) B Ow � UTILITY AC DISCONNECTEWDCX to AC dBCOTfEGf SVTdI 3 FOUTSS]E OARAOE WTMM 9M3HT FRpA THE M '/Wl�BERVX£PIAIEI 8 ROM THE MMN SE-CE PANEL) SE—AND B BEMICE PoINTAW D UTILm MET¢UNp m1w MEI¢IRJO 8 m TO ELECOSC eMm To El1:CIRIC f-DAMSN'-y unLm mlD uTEmm 0 PLAN 3 (SCHEME 1) PLAN 3 (SCHEME 2) v1 Elevation B (5.03 M) Elevation B (5.03 M) z O m Lu 3' 3' = a. 15 MODULES ---------- 15 MODULES Q P SPR-X21-335-BLK-C-AC P SPR-X21-335-BLK-C-AC d TILE HOOK(FLAT TILE) T TILE HOOK FLAT TILE) N ? INVISIMOUNT(ABOVE TILE) 3 INVISIMOUNT ABOVE TILE) 0 B W w ra o naooF JUNCTON BOX o o RooF AccESE PorJr C� M 5.12 n ul OPPORTUNITY 007942 0 JUNCTION BOX LL FroDF,TccEEEPDwr TN.E RODE 0 PROJECT D-0053493 Ell A. 0 0 DATE DRAWN 06-14-2016 0 0 a 0 ih 3 W DRAWN BY MMENDOZA SU&PANEL IINSCE TAMADEI BUBFAN¢(INSIDE 6NIgE) UTILITY AC dSLONNECTSWffCH UTEITYAC dSLONNECT SWITCH (PoWI&H-H EWTIWSCHT (OUT&DEMMOE WRHIN&dlf a BATHE MAS 9ERVCE PIJEL) FRpA THE MAN BERVMEPAN¢) .-ICE-.-D 0 0 eFJrvwEPoINT— 0 0 DATE CHECKED 06-14-2016 unurr METENwD urury METERrxi TO O t—EIS-S TO NWdU 'f/, CHECKED BY EE-GBFS ELE—c UTILITYORC UTILmdJC ( ID,,�Ii� ��1• `W �J/] r O SHEET M Z PLAN 3 (SCHEME 1) PLAN 3 (SCHEME 2) SOLAR-Al2 Elevation C (5.03 M) Elevation C (5.03 M) RISK CATEGORYII,V= 110 MPH BASIC WIND SPEED, N 0 C S EXPOSURE C, 10 PSF GROUND SNOW LAAD,Ss= 2.Og f y ,0, FFh SUBFLASHING r < a '" a lj� MAX MAX y a o SPACING CANTILEVER MAX UPLIFT DOW FN ORCE INVISIMOUNT RAIL000< y ��n E ° Z 5-2 25 psf 28 psf QUICK HOOK a o o y5 ZONE 1 48" 24" •� _ u 260 lb 296 lb PV MODULE a 7 o 46 psf 28 psf L m e u y a S ZONE 2 48" 24" 480 lb 296 lb BASE PLATE o _ u U a 8n ZONE 3 24" 20^ 73 psf j 28 psf LAG BOLTS 380 lb 148 lb c • NOTE: POINT LOADS SHOWN IN TABLE ABOVE(lb)ARE FOR EACH ATTACHMENT ASSUMING MAX SPACING SHOWN IS USED. CONCRETE TILE ROOFING QPDFESS/O� • LOADS SHOWN ARE LRFD LOADS. ATTIC TRUSS OR ND73562 zm RAFTER 24"OC ¢ Bp 1z7355 a REFER TO SUMMARY TABLE REFER TO SUMMARY TABLE MAXIMUM FO MAX SPAN AND CANTILD ER FOR MAX SPAN AND CANTILEVER 'l 0/V 2"X4"TRUSS OR RAFTER I qTP Of Ok%_ ' SPACED O 24"OC MAX �I�I� T SSSS MPED STRUCTURAL CALCULATION ON FILE INVISIMOUNT RAILS (2)PER MODULE44-0 FIGURE 2: INVISIMOUNT WITH QUICK HOOK SIDE VIEW DETAILS SUNPOWER MODULE(TYP.) MID CLAMP CK HOOK ---- ---- — ---- (SEE FIGURE 2,(3 P.) --- -- --- ---- INVISIMOUNT RAIL PV MODULE PV MODULE4It vy� (SEE FIGURE 2,3&4) ra I I I I I I I I I I I I ( QA pli QUICK HOOK �5 CONCRETE TILE ROOFING SUBFLASHING \ END CLAMP /. ROOF SHEATHING BASE PLATE \ / i WITH)5/116"WASHER 0 CENTER TYP. N PRE—DRILL REQUIRED. 2"X4"TRUSS OR RAFTER 2 1/Y MIN.EMBEDME T INTO RAFTER. \ / (DOUGLAS FIR OR EQUAL) •WEIGHT OF INSTALLED ARRAY: 3.5 PSF m Ir' •STAGGER ATTACHMENTS WHEREVER POSSIBLE MID CLAMP 0.5"MIN ° FIGURE 1: PLAN VIEW, TYPICAL ARRAY LAYOUT FIGURE 3: INVISIMOUNT WITH QUICK HOOK DETAILS @ RAFTERS z 0 INVISIMOUNT RAIL MAX CANTILEVER MID CLAMP '> END CLAMP PER SUMMARY TABLE W 09 v a < a Z END CAP 0 CONCRETE TILE ROOFING PV MODULE PV MODULE ° SUBFLASHING L r T=°- OPPORTUNITY QUICK HOOK PROJECT 15/32"MIN. BASE PLATE (3)16d SINKER NAIL OR ROOF SHEATHING DATE DRAWN 06-07-2016 a a a a TOE NAIL ON EACH ENDz�A (3)16d SINKER NAIL OR TRUSS OR RAFTER TOE NAIL ON EACH END DRAWN BY PBASAUAJE SPACED 0 24"OC MAX NOTE:4"X6"FLAT BLOCKING TRUSS OR RAFTER ONLY REQUIRED WHERE (2) 5/16"X 3 1/2"S.S.LAG BOLT SPACED O 24"OC MAX DATE CHECKED 06-07.2016 14" 14" T I ATTACHMENT POINT IS REQUIRED WITH "MIN WASHER EMBEDMENT CENTER TYP. BETWEEN RAFTERS/TRUSSES IR 2 E— MIL QUIRED. INTO RAFTER. ORDER TO MEET MAX CANTILEVER PRE—DRILL REQUIRED. CHECKED BY P'CODD 96 CELL MODULE 72 CELL MODULE SHOWN IN FIG.1 SUMMARY TABLE. NOT TO SCALE •INVISIMOUNT RAILS SHALL BE POSITIONED IN THE NON-CROSS HATCHED REGIONS SHEET FIGURE 5: INVISIMOUNT MOUNTING CLAMP POSITIONING DETAILS FIGURE 4: INVISIMOUNT WITH QUICK HOOK DETAILS @ BLOCKED LOCATIONS SOLAR-S1 DESIGN PARAMETERS FLAT ROOF HIP ROOF(70< 6< 270) LU m E a wooaa WIND LOADS �. to � a „ es M July 13,2015 „ 3 '/�.r U TO WHOM IT MAY CONCERN: , l RISK CATEGORY: II 5 "eePa/� ° o y Structural load on Invisimoant Roof Mounting PV system is determined in accordance with the standard F„ O Z v+ L S F EXPOSURE: C ASCE7.10 Minimum Design LoadsforBuddings and Other Structures.Calculations refers to the following < rq O o m MAXIMUM WIND SPEED PER CBC 2013,V: 110 MPH eectioneofASCE7-l0andothmoodell MAXIMUM ROOF HEIGHT,H: 40 FT _ 8 Wind loads are calculated per Section 30.4"Part 1:Low-Rise Buildings"(not the Part 2`Simplified" MAXIMUM ROOF SLOPE: 12:12 I method). RE a < Bg MAXIMUMRAFTERSPACING: 24" I Snow loads are calculated per Chapter7. = u v 00 u MAXIMUM LEAST HORIZONTAL DIMENSION OF BUILDING,L: SOFT Seismic loads are calculated per Chapter 13.The force Fr is applied horizontally in the down-slope TOPOGRAPHIC FACTOR,kzt: 1.0 I �o:,��' I ��a,y direction,concurrently with the downward vertical force 0.2SmW WIND DIRECTIONALITY FACTOR,kd: 0.8 5 I I - Combinations of loads are calculated using"Strength Design"(LRFD)per Section 2.3. v VELOCITY PRESSURE EXPOSURE COEFFICIENT,kh: 1.04 Maximum aHachment spacing is determined based on the capacity of the aluminum rail,aluminum INTERNAL PRESSURE COEFFICIENT,GCPi: 0.0 S• I I rS I quick hook assembly,L-Foot assembly,and lag bolts. I \ ,/ • Lag bolt capacity is calculated following the requirements ofthe NOS standard. Qpl,1FEES/D'vf , Should you have any additional questions,please feel free to contact me. .s� `'\JGjC �47�r4 xS 40 S h Sincerely, co Q NO.73552 �^ "¢ EO 12,31.16 S' SNOW LOADS - � P i0k� GABLE ROOF(A <_ 70) GABLE ROOF(70< 6 5 45°) � ' U D MAXIMUM GROUND SNOW LOAD,pg: 10 PSF * * CALCULATION PED S R CTU FILEAL EXPOSURE FACTOR,Ce: 0.9(FULLY EXPOS ED) ' DIV1 a3 THERMAL FACTOR,Ct: 1.2(UNHEATED AND OPEN AIR STRUCTURES) Qe fpLt SLOPE FACTOR,Cs: PER FIGURE 7.2c(UNOBSTRUCTED SLIPPERY SURFACE) ❑ INTERIOR ZONES SNOW IMPORTANCE FACTOR,Is: 1.0 ZONE l Peter Todd,P.E.I Group Lead,Stmchaal Engineering SunPower corporation I Office:S 10.260.8202 Z pet"Atuc d(alainpower.wm O SEISMIC LOADS PT1 END ZONES I -J ZONE 2 I SHORT PERIOD SPECTRAL ACCELERATION,Ss: 2.0g I � �� I `\� U SITE COEFFICIENT,Fa: 1.0 COMPONENT AMPLIFICATION FACTOR,ap: 1.0 CORNER ZONES SEISMIC COMPONENT IMPORTANCE FACTOR,Ip: 1.0 3` I S I I ZONE 3 COMPONENT RESPONSE MODIFICATION FACTOR,Rp: 1.5 I I SITE CLASS: D 1414 Harbour Way South www SUNPOWER P: 1.510.540.0550 /X /X Richmond,CA 94804 USA F:1.510.540,0552 y� F FIGURE A: ROOF ZONES PER ASCE 7-10 FIGURE B: STRUCTURAL SUMMARY q ng fez'! Loa d Calculation ParametersParameters5/16"Diameter Lag Bolt Streth IC. Rail tribunry width 2.6 it AIDS LRFD •••777 O Flat.of snow load pf 7.6 psi Wlndvelocitypressan qh 27 per Number of bolts= 2 seine•Loads Thread penetration= 1 Inch Slap Load In ps 7.6 3 psf Bolt diameter,D= 0.3125 Inch Sloped Roof Snow Load ].6 pal Wind Load Upward zone 12 pw:omen -21.41 pal Specific gravity,G= 0.49(Douglas Fir or equal) Wind Load Upward Zane z pw_1=2 ae.46 Pat 51 WI[hdrawal value,W= 258 1b;NDS Table 11.2A Wind Load Upward Zone 3 px_zom3 -76.94 gel Wind Load Downward P.-down 25 Pat Load duration factor,Cd• 1;Section 10.3.2(LRFD design) m 0 Seismic Load Fp I. Wet service factor,Cm• 1;Section 10.3.3(wood In continuously dry condition) Seismic Load Fp_awer_rstift 1.6 Temperature factor,Ct= 1;Section 10.3.4 no sustained temp>100'F Seismic Load Fp lower oril 7.2 P ( P ) Selunlc Load Fp_.M 3.6 End grain factor,Call= 1;Section 11.5.2(no end grain) Load Countered- Comoro 1 10 pitToe-Nall factor,Ctn= 1;Section 11.5.4(no toe nail) 1. 7.W2D+1.68+0.5w Combo 2 57 pitFormat conversion factor,Kf= 3.32;Table N3(Connections) 1.20.0.68+1.OW Combo 74 pitResistance factor,4z= 0.65;Table N2(Connections) 0.9DN.0W Combo 4(Zons l) -6543 pX y 0.8D+toW Combo 5(20oa 2) -1 W.91 p8 Time effect factor,A= 1;Table N3(Wind/Seismic) z 0.9D+1.0W Combo 6(Zone 3) .190.11 pM (p7n= 1115 lb;Table 10.3.1 1.20.1.0E+0R8 Combo 11 15 pit 1.4D Combo 7 7.4 pit1.20+1.68 Combos 14 p8 Ili 1.2D.0.58 Combo d5 ps rA 0.9D CORai 10 4.8 pit 1.2D.1.OE.o.2S Cord,012 14 pit i--I Worst Caw Upin Zone l WCzowl 65 pitWordCawUpinzone2 WC-2 120 Pit Wesel Case Uplift zone 3 WCzcne3 190 pit fi7 Worse Case Downward WCaown 74 pit p4 Worst Case Seismic Demand WCeq is PH Worst Case Sheer or Uplift Cases WCahear_up 4.8 pit Worst Case Shear for Downward Cases WC.Ise tlown 14 pit O Worst Case Sherd i Seismic Cases WCehedr_eq 14 p8 Wkft Ind tons term, Wroth of edge dcarrwr zones a 5.0 X Wzimum Allowable Spacing of Alleehrounds Maximumellowable a..eft.nt spading,zonal Leli-ed ,net 48 1n Maximum allowable edechment spacing,mm2 Leilowed zone2 48 In Mexlmum alowable ahachment spacing,zoM3 Laioww_zW93 24 In Maximum allowable-filever,zone 1 Candleverzanel 24 In �>iu ' Maximum allowable cantilever,zone2 Cen6ieversone2 24 In RE Mexlmum allowaoe canalever,zone 3 Cannlaverzane3 20 In Rail Bening Rail Bending Up Strength Mn_mll up 540 bX OPPORTUNITYFall Banding Down Strength Mn nil down 580 Ib-X di L-Fool L-Foot Teralon Strength Tn L-Ford 510.0 to L-Foot Compression Strength Crl_L-Faot 999.0 lb PROJECT L-Foot Shear Strength Vn L.Fool 195.0 lb Ills Hook Tile Hook Toulon Strength Tnjlook 530.0 It DATE DRAWN 06-07-2016 Tile Hoak Compression Strength Cn_hook 450.0 lb Tile Hook SMar Strength ItsCompgeasion Vn_ho0k_down 67.0 Ib Tin Hook Sheer Strength for Tendon Zone 1 Vn hook_z1 127.0 Ib Tile Hook Sm"Strength for Tendon Zone 2 Vnj-kz2 8601b DRAWN BY PBASAILVE Tile Hook Sheer Strength for Tarrson Zone 3 Vn_hook_z3 15.0 Ib Tile Hoot Shear Strength for EO Case Vn_hook oq 297.0 Ib DATE CHECKED 06-07-2016 CHECKED BY PTODD NOT TO SCALE sHhfcr FIGURE C: INVISIMOUNT STRUCTURAL CALCULATION FIGURED: LAG BOLT STRUCTURAL CALCULATION SOLAR-S2 2/17/2015 OIMSEC6E961 M.M,g Systems.Mwntng Dewcea ClampMOw,c ad Grard UVsfo Us.,MPMwdB,,MW,lesad Panels • z go ONLINE CERTIFICATIONS DIRECTORY ____.... W = p N ��z CERTIFICATE OF COMPLIANCE QiMs.eaesgsi �j F Mounting Systems,Mounting Devices,Clamping Devices and Ground Lugs for Certificate Number 20150223-E466981 >^ a a 0 0 ------ - - Report Reference E466981-20140903 Use with Photovoltaic Modules and Panels v, a a a d Issue Date 2015-FEBRUARY-23■ Residential Mounting Paae Bottom g y c � C5z F z y a Mounting Systems,Mounting Devices,Clamping Devices and Ground Lugs for ,m _ z Issued to: SUNPOWER CORP Use with Photovoltaic Modules and Panels m � °S g 77 RIO ROBLES Z a x x a2 MCN.e',rdm Pa^a and va, ..v- Ern damp am 9aJ SAN JOSE CA 95134-1859 al mfo,tnanon for Mo nnn s n D ntl Gro M Lug,for use mth Pnaav 1 rm v °y it Pals C _ 0 g D O C U •6 PW This is to certify that MOUNTING SYSTEMS,MOUNTING DEVICES,CLAMPING SURPowER DORP E9659e1 S representative samples of DEVICES AND GROUND LUGS FOR USE WITH 77 RIO ROBLESnwlpm� ,�g PHOTOVOLTAIC MODULES AND PANELS SAN DOSE,CA 95134 USA 'c ,rescsgatea USL-InvisiMouM Mounting and Bonding Systems for use with vestigatee m rar sr#tem Fire ombl b[n far Mechanical Cl(A,5 or CPmbinatbn Photovoltaic Modules,consisting of the following components: L- Can.No. eowara9 tnaabg (A,a or d wan QPOF ESS/0 Foot,Rail,Rail Splice,Mid Clamp,Ground Lug Assembly. Ph 'Y9 otovonaic aau mon9 srscem ����p1. !Fy InwslMount-consisting A UL Usted I Motlulas: w,o::a -•�oa�np ka��s Pay spy eP ....,.., ern c,,, Theses stem components have also been evaluated for a Class y p of Me following Sunpower Corp:Models SPR-XYY-###,where YY m A System Fire Classification for,steep-sloped roof with Type 2 components:L-Foot, represents numbers er L9,20 or II,and### w C 73562 ® Raa,Rail SPbce,Mid repnoth ras any number from 365 to rep ark eae 2 Fry 12.01-16 modules. Clamp,Ground Lug he 233;SPR-EYY-###,where W represents y See addendum a for additional information. A inbly am, e,19,m ar n,aaa l 25 represents T ( peg ) any number fh ah b v.antl 250 to 225.Al J'f (,`/y maaels meam,ea moat nave aria Gen s fame and 9T 0 have a type z modae dwaaen7nuon. F OF CAL(F� Have been investigated by UL in accordance with the Lan uaaatea on 2014-1 -2a e pre a Dgd — Standard(5)indicated on this Certificate. Oae_ Print th—ane Terms of use Paae rdd wECASCUILATIONPED STON STRUCTURAL Standard(s)for Safety: UL Subject 2703,The Outline of Investigation for Mounting 201S UL LLC Systems,Mounting Devices,Clampin/Retention Devices,and when the UL leaf Mark son.b procua,or th,the wok,r vcamen "Is IMutletl In the UL Mark,please search the UL Environment � 9 9 9atiF35:far am I oriel nfa,mat on regarn rig to s product s amnabon Pa a j xus rs .. .:�: a od war ar., Ground Lugs for use with Flat-Plate Photovoltaic Modules and wanant e� year part n•h ws rrp under UL'.rice of a company s r prodaCt n th s database tloes nat n tself assure that be Celt so dent fled have been manufactures Panels S,hv a.Al Follow'Jp Sery a O 1 pr,lud.bearing[M1e UL Mark mould be cons tiered to be Cert fietl and wveretl uMet UL s Follow-Up e-aa Servce Always look for the Mari,. patluct. crap p 1 e al,10111 Map�pn_- - seo"a., °"o'°Seri Additional Information: See the UL Online Certifications Directory at Y UL perm tr the reprecuR cn of td - mnta Sy m the mb., .,of othon O rectory subbed to the d:n t rig coed t om:1 The Guide m cemk,.-oe, annd..r<,n,l,n«tiet»ae�� www.ul.eomldatabase for additional information IMarmahaa,Assemblies,co"etraa-o awn If,systems,r dillmlita)aas(faes>mast ep Presentee t tries en Car ana.a a aaa- �urFnvrer misleatling manner,w,d-cut any mariDulanon of the tla[a(or dawings)2 The statemem"Reprinted from[ne Online Certlflcatlons DlreRpry ale ra i� a s w,M,Pamaaslon from U-"m,stu,,pear adjacent tome eAmded material.In add,bon,the mMnt d material must,miwe a mpyrlght mt,u in Only those products beating the UL Listing Mark should be considered as being covered by UL's the rolomng foa"ao-.- 2m s _LLc 0 - Listing and Follow-Up Service. Q The UL Listing Mark generally includes the fallowing elements:the symbol UL in a circle:@ with the d..= , .ra 9a,e m ool�c.mnerrl amwara mar maemn.,sao:�,tnmt or word"LISTED';a control number(may be alphanumeric)assigned by UL;and the product category U -- -- name(product identifier)as indicated in the appropriate UL Directory. rwr Look for the UL Listing Mark on the product. V ,ao•a.h,m.ti.r,.. P Ir.,.,,�,�,.e"�"r.,.e,"r„T�«,a,r»,,.,�,.,00rr,a�w ,.,.aarma,.. �m�.a l�.r�.,.w�C� .�P... (j� zA e a Pageca2 ¢ Mlp://database ul epnlcq�bNXYVAemplala�LISEKrI1FRAME/sYdvpege.l#ml7rwns=QIMS E46�Bi8ccreMrt611e=Mar&rg+SYstens.+MouremeDences,+... tli A F z FIGURE A: INVISIMOUNT DATA SHEET FIGURE B: CERTIFICATE OF COMPLIANCE FIGURE C: CLASS A FIRE RATING UL LISTING 5 z 0 F 0 z 0 w x 0 f u 0 m z OPPORTUNITY PROJECT DATE DRAWN 06-07-2016 DRAWN BY PBASALLAJE DATE CHECKED 06-07-2016 CHECKED BY PTODD NOT TO SCALE SHEET SOLAR-S3 FIGURE A: THREE LINE DIAGRAM - 3.02 kWDC (� _ a W w -v u ELECTRICAL NOTES FIGURE B: LABELING SPECIFICATIONS N a o o � 1. ALL SEAL TIGHT FLE%ISLE METAL CONDUIT(OR EQUIVALENT)TO BE BONDED TO GROUND AT U 3 COUPLINGS ON BOTH ENDS. WARNING zO ELECTRICAL SHOCK HAZARD. DO NOT TOUCH � TERMINALS.TERMINALS ON BOTH THE LINE AND ^ 2. CONDUIT ENTRY/CONNECTION TO ELECTRICAL ENCLOSURES SHALL BE SUITABLE FOR GROUNDING THE LOAD SIDES MAY BE ENERGIZED IN THE O AND SHALL BE SEALED AGAINST ENVIRONMENT,SUCH AS WATER,INSECTS AND RODENTS.CONDUIT OPEN POSITION < m O c w >I SHALL NOT ENTER FROM TOP OF ELECTRICAL EQUIPMENT IN OUTDOOR LOCATIONS WITHOUT J < x V P a SITE SPECIFIC APPROVAL FROM SUNPOWER.IF GRANTED APPROVAL FOR TOP ENTRY,ONLY RIGID JUNCTION BOX CONDUIT WITH MEYERS HUBS TO BE USED. u c < .ai �g 3. INSULATED BONDING BUSHINGS T USED ON ALL CONDUIT TERMINATIONS REGARDLESS OF PV AC DISCONNECT 0 VOLTAGE.THE INSULATING FITTINGS S CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED LJ S SHALL BE SUITABLE FOR BONDING TO GROUND IN AC DISCONNECT RATED AC OUTPUT CURRENT 11.97 A •' y( ACCORDANCE WITH NEC 250.92.INSULATED BOX CONNECTORS DO NOT MEET THIS REQUIREMENT. NOMINAL OPERATING AC VOLTAGE 240 V 4. PROPER LISTING EXPECTED FOR CONDITIONS OF USE ON ALL LUGS,FITTINGS,CRIMPS,ETC. S. ALL CONDUIT BEND RADII TO CONFORM TO THE NEC MINIMUM BEND RADII REQUIREMENTS. WARNING DUAL POWER SOURCES 6. MINIMUM CLEARANCE SHALL BE MAINTAINED PER NEC FOR ALL NEW EQUIPMENTS TO BE INSTALLED. WARNING INVERTER OUTPUT CONNECTION, QppFES$/ DO NOT RELOCATE THIS 7. EXISTING GROUNDING ELECTRODE SYSTEM MUST MEET NEC AND LOCAL UTILITY REQUIREMENTS. OVERCURRENT DEVICE (� ,iy, S/q/� CAUTION POWER TO THIS BUILDING IS 47 8. COPPER CONDUCTORS SHALL BE USED UNLESS SPECIFIED. ALSO SUPPLIED FROM THE y a FOLLOWING SOURCES LOCATED a L�7jj AS SHOWN 9. AC WIRING SHALL BE UPSIZED IF VOLTAGE DROP EXCEED 2%. BP a+a1-1e 10.PV SYSTEM COMBINER PANEL SHALL BE USED ONLY WHEN PV PRODUCTION METER IS REQUIRED BY PLAQUE INDICATING SOURCES: �CFQTRIGP�'�* THE UTILITY.IF METER IS NOT REQUIRED,PV SYSTEM BREAKERS CAN BE DIRECTLY INTERCONNECTED MAIN —SOLAR PV 11.97 A.240 V '9Ik TO THE EXISTING SUB-PANEL OR MAIN PANEL. SERVICE -UTILITY GRID 200A, 240V OF CAU PANEL 11.TYPE NM-B CONDUCTORS(ROMEX)SHALL NOT BE USED FOR EXTERIOR APPLICATION.ITSHALL BE USED ONLY INSIDE ATTIC AND IN WALL CAVITY. 12.RATING OF THE MAIN CIRCUIT BREAKER MAY VARY.IN ANY CASE,SUM OF THE MAIN BREAKER AND PV BREAKER MUST NOT EXCEED 120%OF THE BUS BAR RATING OF THE MAIN SERVICE PANEL. Z REFERENCES.ALL REQUIREMENTS ARE MET BY. **2013 CALIFORNIA ELECTRICAL CODE(CEC)** o NOTES: m U NOTE: WHEN A BACKFED BREAKER IS THE METHOD OF UTILITY INTERCONNECTION, S AS DC POWER IS INTERNAL BREAKER SHALL NOT READ"LINE AND LOAD". �d TO THE MODULE,GROUNDING } 22 U ELECTRODE CONDUCTOR ARRAY (GEC)FOR GROUND FAULT PROTECTION IS REQUIRED FOR ROOF MOUNTED ARRAYS. J g d THE MODULE OR ARRAY IS NOT Ln REQUIRED. LL.I REFER TO GROUNDING DETAILS IN PLAQUES SHALL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERS, z 0 of SHEET SOLAR-E3. OR ELECTRO-PHOTO PLATING,IN A CONTRASTING COLOR TO THE PLAQUE.PLAQUE SHALL p 0 T BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS. N W Y 01 ALL SIGNAGE IS TO BE RED BACKGROUND WITH WHITE LETTERS. M INCOMING SOURCE FEED CAUTION SOLAR CIRCUIT LABELS TO BE INSTALLED EVERY IW AND WITHIN 1'OF ALL TURNS, (NOT CENTER-FED) S M Q INTEGRATED MICROINVERTER, $k MI-C-320-US208/240-XX-UL 1741 BENDS&PENETRATIONS. r M W CAUTION SOLAR CIRCUIT LABELS TO ALSO BE REFLECTIVE WHEN INSTALLED IN THE BUILDING Q r Z ATTIC&ON ROOFTOP. r U) F J A DIRECTIONAL PLACARD IS REQUIRED,NEEDS TO SHOW LOCATION OF PANELS, UTILITY /} 1 i = a DISCONNECT,&ALL ELECTRICAL EQUIPMENT. BIDIRECTIONAL I /� CURRENT TRANSFORMERS(IOOA) N ,A 1/2"FMC In vOi U \ AC MODULE (2)#22 AWG TWISTED PAIR g a EXTENSION CABLE 0 IL _ _ _ _ _ INSTALL \\ I = V s �J END CAP a JUNCTION BOX o w w W TRANSITION BOX MAIN ELECTRICAL PANEL I A o W ( ) 240/12OV,200A(MIN), SUNPOWER MODULES UTILITY POINT OF INTERCONNECTION 1 1 MO 2P I 0 m SPR-X21-335-BLK-C•AC THE COMBINED OVER CURRENT J J ; 9 AC MODULES o c o PROTECTION CANNOT EXCEED u 120%OF THE BUSBAR RATING BRANCH CIRCUIT*1 Aloomof — — — — — - TO HOUSE "I a LOADS �� O 1"FMC EMT TRANSITION TO FMC (2)#10 AWG THWN•2 CONDUCTOR BREAKERS SHALL BE INSIDE ATTIC. INSTALOLED IN WALL CAVITY INSTALLED OPPOSITE_ SEE FIGURE A IN SOLAR E2 ENO OF THE MAIN Z BREAKER Q 1"FMC (2)*10 AWG THWN-2 CONDUCTOR (1)*10 AWG THWN-2 GND I 15A,2P UJ SUNPOWER > MONITORING 20A,2P PVSSX W L — — — — — — — — — — — — — — — — — T5e 0 I _ u u L - -- - INLl ETHERNET w - - - - - - - - - - - - - - - - - - - B7CUWIRE rl GND CONNECTION O BARE I - - - - 1 J TO MODECABLE FIGURE C: ELECTRICAL CALCULATIONS — — — — J 1n^FMC i IT 1 EXISTING (2)#14 AWG THWN-2 CONDUCTORS AC,BRANCH 1 UTILITY-LOCKABLE SAFETY SWITCH 30A,240VAC -BIND (1)#14 AWG THWN-2 GND OPPORTUNITY 007942 IN WALL CAVITY ROOF JCT BOX M CUTLER-HAMMER DG221URB OR EQUNALENT BUB-PANEL WIRING 1 #10 LOCATED OUTSIDE WITH VISIBLE KNIFE BLADES NUMBER OF MODULES PER BRANCH CIRCUIT B REFER AC DISCONNECT SPECIFICATION-SOLAR-E3 SHEET PROJECT D-0053493 VOLTAGE 240 V BRANCHCURRENT:I Uf= 11.97A DATE DRAWN 06-14-2016 MINIMUM WIRE AMPACITY:IMAX=OUT x 1.28 14.96 A CONDUCTOR DE4tATINO DRAWN BY MMENDOZA MAXIMUM AMBIENT TEMPERATURE 40'C TEMPERATURE DE-RATING COEFFICIENT 0.91 FILL DE-RATING COEFFICIENT 10 DATE CHECKED 06-14-2016 [WIRE MIN=IMAX I TEMP_COEFF/FILL_COEFF 16.44A CONDUCTOR SIZE PER NEC #10 CHECKED BY EE-GBPS CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10 NOT TO SCALE VOLTA E DROP AT B5 FT DISTANCE OVERCURRENT PROTECTION f�!tE.22PMINIMUM OCPO=IOUT x 125NEXT LARGER OCPD SIZE SOLAR-E1.1 FIGURE A: THREE LINE DIAGRAM - 4.02 kWDC W FIGURE B: LABELING SPECIFICATIONS ~ "m ELECTRICAL NOTES y 'a a g � 1. ALL SEAL TIGHT FLEXIBLE METAL CONDUIT(OR EQUIVALENT)TO BE BONDED TO GROUND AT 0p D w �' WARNING a GOo COUPLINGS ON BOTH ENDS. ELECTRICAL SHOCK HAZARD DO NOT TOUCH ^ O Z " " o-g TERMINALS.TERMINALS ON BOTH THE LINE AND •..r ¢ m O o Z g � 2. CONDUIT ENTRY/CONNECTION 70 ELECTRICAL ENCLOSURES SHALL BE SUITABLE FOR GROUNDING THE LOAD SIDES MAY BE ENERGIZED IN THE K 61 AND SHALL BE SEALED AGAINST ENVIRONMENT,SUCH AS WATER,INSECTS AND RODENTS.CONDUIT OPEN POSITION 7 SHALL NOT ENTER FROM TOP OF ELECTRICAL EQUIPMENT IN OUTDOOR LOCATIONS WITHOUT L a 2= SITE-SPECIFIC APPROVAL FROM SUNPOWER.IF GRANTED APPROVAL FOR TOP ENTRY,ONLY RIGID JUNCTION BOX .U. .-. uwi3 CONDUIT WITH MEYERS HUBS TO BE USED. p ti oe U of 3. INSULATED BONDING BUSHINGS TO BE USED ON ALL CONDUIT TERMINATIONS REGARDLESS OF PV AC DISCONNECT V CAUTION SOLAR ELECTRIC SYSTEM CONNECTED VOLTAGE.THE INSULATING FITTINGS SHALL BE SUITABLE FOR BONDING TO GROUND IN RATED AC OUTPUT CURRENT 15.96 A L/ g g ACCORDANCE WITH NEC 250.92.INSULATED BOX CONNECTORS DO NOT MEET THIS REQUIREMENT. AC DISCONNECT NOMINAL OPERATING AC VOLTAGE 240 V �a 4. PROPER LISTING EXPECTED FOR CONDITIONS OF USE ON ALL LUGS,FITTINGS,CRIMPS,ETC. S.ALL CONDUIT BEND RADII TO CONFORM TO THE NEC MINIMUM BEND RADII REQUIREMENTS. WARNING DUAL POWER SOURCES QppFESS/(yt,- 6. MINIMUM CLEARANCE SHALL BE MAINTAINED PER NEC FOR ALL NEW EQUIPMENTS TO BE INSTALLED. WARNING:INVERTER OUTPUT CONNECTION, 00 NOT RELOCATE THIS 7. EXISTING GROUNDING ELECTRODE SYSTEM MUST MEET NEC AND LOCAL UTILITY REQUIREMENTS. CAUTION: P P WER TO TH DEVICE OWER TO THIS BUILDING IS =2 O SUPPLIED FROM THE a 4 8.COPPER CONDUCTORS SHALL BE USED UNLESS SPECIFIED. ALS FOLLOWING SOURCES LOCATED AS SHOWN. EV 8331-18 9.AC WIRING SHALL BE UPSIZED IF VOLTAGE DROP EXCEED 2%. 10.PV SYSTEM COMBINER PANEL SHALL BE USED ONLY WHEN PV PRODUCTION METER IS REQUIRED BY PLAQUE INDICATING SOURCES: FCTR\GPaa�Q THE UTILITY.IF METER IS NOT REQUIRED,PV SYSTEM BREAKERS CAN BE DIRECTLY INTERCONNECTED MAIN -SOLAR PV: 15.96 A,240 V ,C OF TO THE EXISTING SUB-PANEL OR MAIN PANEL. SERVICE -UTILITY GRID 200A,240V PANEL 11.TYPE NM-B CONDUCTORS(ROMEX)SHALL NOT BE USED FOR EXTERIOR APPLICATION.IT SHALL BE USED ONLY INSIDE ATTIC AND IN WALL CAVITY. • 12.RATING OF THE MAIN CIRCUIT BREAKER MAY VARY.IN ANY CASE,SUM OF THE MAIN BREAKER AND PV BREAKER MUST NOT EXCEED 120%OF THE BUS BAR RATING OF THE MAIN SERVICE PANEL. Z REFERENCES.ALL REQUIREMENTS ARE MET BY: Q **2013 CALIFORNIA ELECTRICAL CODE(CEC)** M Q NOTES: U_ NOTE: WHEN A BACKFED BREAKER IS THE METHOD OF UTILITY INTERCONNECTION, LL AS DC POWER IS INTERNAL BREAKER SHALL NOT READ"LINE AND LOAD". p ((j TO THE MODULE,GROUNDING i 7 V LU LU ELECTRODE CONDUCTOR(GEC)FOR GROUND FAULT PROTECTION IS REQUIRED FOR ROOF MOUNTED ARRAYS. QQ THE MODULE OR ARRAY IS NOT Q U Q U0 REQUIRED. LLJ REFER TO GROUNDING DETAILS IN PLAQUES SHALL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERS, C) °- SHEET SOLAR-E3. OR ELECTRO-PHOTO PLATING,IN A CONTRASTING COLOR TO THE PLAQUE.PLAQUE SHALL C ? I BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS. _ f1 w J ALL SIGNAGE IS TO BE RED BACKGROUND WITH WHITE LETTERS. (n T+T g m Q INCOMING SOURCE FEED CAUTION SOLAR CIRCUIT LABELS TO BE INSTALLED EVERY 10'AND WITHIN 1'OF ALL TURNS, (NOT CENTER-FED) INTEGRATED 08/240MICROINO(-UL 1, (Y' ml-c-3zo-u52oe/2ao-xx-uL 1741 BENDS&PENETRATIONS. Q � M W CAUTION SOLAR CIRCUIT LABELS TO ALSO BE REFLECTIVE WHEN INSTALLED IN THE BUILDING r a r z ATTIC&ON ROOFTOP. I I I V N LU A DIRECTIONAL PLACARD IS REQUIRED,NEEDS TO SHOW LOCATION OF PANELS, MONALLL'I'! I T 1 Z LU :mwOlmDISCONNECT,&ALL ELECTRICAL EQUIPMENT. BIDIRECO I METER ^ N ,A CURRENT TRANSFORMERS(100A) J \ \ \ 1/2"FMC " N U \\ AC MODULE (2)#22 AWG TWISTED PAIR f N m EXTENSION CABLE I 0 INSTALL \ t U u END CAP JUNCTION BOX I �_0A W (TRANSITION BOX) MAIN ELECTRICAL O 00A(M N), MOB I o y W SUNPOWER MODULES ❑ UTILITY POINT OF INTERCONNECTION 1 1200A,2P 3 SPR-X21-335-BLK-C-AC THE COMBINED OVER CURRENT JJ JJ PROTECTION CANNOT EXCEED m 12 AC MODULES o 0 120%OF THE BUSBAR RATING V BRANCH CIRCUIT#1 ROOFTOP !-y-p� c • • • ATTICS\ m O TO HOUSE ] �\ Q LOADS ISO I V FMC EMT TRANSITION TO FMC (2)(10 AWG THWN-2#0 AWG THWN 2NGND OR BREAKERS SHALL BE INSTALLED OPPOSITE INSIDE ATTIC. I INSTALLED IN WALL CAVITY END OF THE MAIN (n SEE FIGURE A IN SOLAR E2 BREAKER I O 1"FMC (2)#10 AWG THWN-2 CONDUCTOR (1)#10 AWG THWN-2 GND ISA,2P �\ SUNPOWER MONITORING 20A,2P PVS5X LU L CATSe C L _ -- h BLACK WIRE I N L2 Ll I ETHERNET " f- CONNECTION BARE CU WIRE i I GND_ _ _ _ TO MODEM CI L FIGURE C: ELECTRICAL CALCULATIONS 4AWEC21 (2)#14 AWG THWN-2 EXISTING CONDUCTORS END (1)*14 AWG THWN-2 GND AC,BRANCH 7 UTILITY-LOCKABLE SAFETY SWITCH 30A,240VAC IN WALL CAVITY OPPORTUNITY 007942 ROOF JOT BOX TO SUB-PANEL WIRING-BRANCH] p10 LOCATED CUTLER-HAMMER RB OR EQUIVALENT OUTSIDE WITHITH VISIBLE KNIFE BULDf3 NUMBER OF MODULES PER BRANCH CIRCUIT 12 REFER AC DISCONNECT SPECIFICATION-SOLAR-E3 SHEET VOLTAGE 240 V PROJECT D-0053493 BRANCH CURRENT:TOUT 15.98A MINIMUM WIRE AMPACITY:IMAX=1 OUT x 125 19.95A DATE DRAWN 06-14-2016 CONDUCTOR DE-RATING MAXIMUM AMBIENT TEMPERATURE 40°C DRAWN BY MMENDOZA TEMPERATURE DE-RATING COEFFICIENT 091 FILL DE41ATING COEFFICIENT 1.0 (WIRE_MIN=[MAX/TEMP COEFFl FILL_COEFF 21.82A DATE CHECKED 06-14-2016 CONDUCTOR SIZE PER NEC #10 CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10 CHECKED BY EE-GBFS VOL TAGE CROP AT 85 FT DISTANCE 151% OVERCURRENT NOT TO SCALE PROTECTION20A,zv MINIMUM OCPD=IOUT x 1.25 19.95A NEXT LARGER OCPD SIZE 20 A SHEET SOLAR-Ell 0 FIGURE A: THREE LINE DIAGRAM - 4.02 kWDC Lu = w =? r 0. o W ELECTRICAL NOTES FIGURE B: LABELING SPECIFICATIONS Z C V o W 3fn 1. ALL SEAL TIGHT FLEXIBLE METAL CONDUIT(OR EQUIVALENT)TO BE BONDED TO GROUND AT WARNING O p p a G COUPLINGS ON BOTH ENDS. ELECTRICAL SHOCK HAZARD DO NOT TOUCH /'1 H O z I^ Z oaf TERMINALS.TERMINALS ON BOTH THE LINE AND m O a w t 2. CONDUIT ENTRY/CONNECTION TO ELECTRICAL ENCLOSURES SHALL BE SUITABLE FOR GROUNDING THE LOAD SIDES MAY BE ENERGIZED IN THEits Owl AND SHALL BE SEALED AGAINST ENVIRONMENT,SUCH AS WATER,INSECTS AND RODENTS.CONDUIT OPEN POSITION ? 0 < = N a_$ SHALL NOT ENTER FROM TOP OF ELECTRICAL EQUIPMENT IN OUTDOOR LOCATIONS WITHOUT L a = o N s SITE-SPECIFIC APPROVAL FROM SUNPOWER.IF GRANTED APPROVAL FOR TOP ENTRY,ONLY RIGID JUNCTION BOX y v < = S CONDUIT WITH MEYERS HUBS TO BE USED. O u £$ PV AC DISCONNECT O .ar �5 3. INSULATED BONDING BUSHINGS TO BE USED ON ALL CONDUIT TERMINATIONS REGARDLESS OF CAUTION SOLAR ELECTRIC SYSTEM CONNECTED $ x VOLTAGE.THE INSULATING FITTINGS SHALL BE SUITABLE FOR BONDING TO GROUND IN RATED AC OUTPUT CURRENT 15.96 A 9 ACCORDANCE WITH NEC 250.92.INSULATED BOX CONNECTORS DO NOT MEET THIS REQUIREMENT. AC DISCONNECT NOMINAL OPERATING AC VOLTAGE 240 V 4. PROPER LISTING EXPECTED FOR CONDITIONS OF USE ON ALL LUGS,FITTINGS,CRIMPS,ETC. S. ALL CONDUIT BEND RADII 70 CONFORM TO THE NEC MINIMUM BEND RADII REQUIREMENTS. WARNING DUAL POWER SOURCES E%/ 6. MINIMUM CLEARANCE SHALL BE MAINTAINED PER NEC FOR ALL NEW EQUIPMENTS TO BE INSTALLED. WARNING: INVERTER OUTPUT CONNECTION, DO NOT RELOCATE THIS .N, S 7. EXISTING GROUNDING ELECTRODE SYSTEM MUST MEET NEC AND LOCAL UTILITY REQUIREMENTS. OVERCURRENT DEVICE h\ / CAUTION POWER TO THIS BUILDING IS B.COPPER CONDUCTORS SHALL BE USED UNLESS SPECIFIED. ALSO SUPPLIED FROM THE CD n FOLLOWING SOURCES LOCATED FiP 9.AC WIRING SHALL BE UPSIZED IF VOLTAGE DROP EXCEED 2%. AS SHOWN 0331-t8 10.PV SYSTEM COMBINER PANEL SHALL BE USED ONLY WHEN PV PRODUCTION METER IS REQUIRED BY �FCTRIC'P �Q D_ �PIAQUE INDICATING SOURCES: THE UTILITY.IF METER IS NOT REQUIRED,PV SYSTEM BREAKERS CAN BE DIRECTLY INTERCONNECTED MAIN -SOLAR PV 15.96 A.240 V �(kU 70 THE EXISTING SUB-PANEL OR MAIN PANEL. SERVICE -UTILITY GRID 200A 240V PANEL 11.TYPE NM-B CONDUCTORS(ROMEX)SHALL NOT BE USED FOR EXTERIOR APPLICATION.IT SHALL BE USED ONLY INSIDE ATTIC AND IN WALL CAVITY. 12.RATING OF THE MAIN CIRCUIT BREAKER MAY VARY.IN ANY CASE,SUM OF THE MAIN BREAKER AND PV BREAKER MUST NOT EXCEED 120%OF THE BUS BAR RATING OF THE MAIN SERVICE PANEL. z REFERENCES ALL REQUIREMENTS ARE MET BY 0 **2013 CALIFORNIA ELECTRICAL CODE(CEC)** M Q NOTES: U WHEN A BACKFED BREAKER IS THE METHOD OF UTILITY INTERCONNECTION, z AS DC POWER IS INTERNAL BREAKER SHALL NOT READ"LINE AND LOAD". } O U TO THE MODULE,GROUNDING J n () ELECTRODE CONDUCTOR(GEC)FOR AC MODULE GROUND FAULT PROTECTION IS REQUIRED FOR ROOF MOUNTED ARRAYS. w S Q LU (n THE MODULE OR ARRAY IS NOT EXTENSION CABLE REQUIRED. INSTALL 06 REFER TO GROUNDING DETAILS IN END CAP PLAQUES SHALL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERS, 0 V SHEET SOLAR-E3. JUNCTION BOX OR ELECTRO-PHOTO PLATING,IN A CONTRASTING COLOR TO THE PLAQUE.PLAQUE SHALL C) z 1 2:(TRANSITION BOX) BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS. 01 w _J < SUNPOWER MODULES '-I ❑ ❑ ALL SIGNAGE IS TO BE RED BACKGROUND WITH WHITE LETTERS. U) M Y m U INCOMING SOURCE FEED 1 Q SPR-X21-335-BLK-C-AC (NOT CENTER-FED) {(� Q INTEGRATED MICROINVERTER, 6 AC MODULES CAUTION SOLAR CIRCUIT LABELS TO BE INSTALLED EVERY 10'AND WITHIN V OF ALL TURNS, MI -C-320-US208/240-XX-UL 1741 BRANCH CIRCUIT#1.2 ROOFTOP BENDS&PENETRATIONS. F co) LU ATTIC 7 U I z CAUTION SOLAR CIRCUIT LABELS TO ALSO BE REFLECTIVE WHEN INSTALLED IN THE BUILDING Q ATTIC&ON ROOFTOP. 1"FMC ^ L X UJ ULI Of (2)#10 AWG THWN-2 CONDUCTOR A DIRECTIONAL PLACARD IS REQUIRED,NEEDS TO SHOW LOCATION OF PANELS, UTILITY (1)#10 AWG THWN-2 GND DISCONNECT,&ALL ELECTRICAL EQUIPMENT. BIDIRECTIONAL 1 VI a = METER CURRENT TRANSFORMERS(IOOA Z) N ,^ L J In Y'U \ \ \ I (2)#22 AWG TWISTED PAIR wP r AC MODULE m — \ EXTENSION CABLE I 0 V U V INSTALL \ w•I END CAP JUNCTION BOX MAIN ELECTRICAL PANEL I 0 o LU (TRANSITION BOX) 240/120V,200A(MIN), UTILITY POINT OF INTERCONNECTION MI 00 .2 SUNPOWER MODULES I —200A,2P I THE COMBINED OVER CURRENT SPR-X21-335-BLK-C-AC O PROTECTION CANNOT EXCEED I I m 6 AC MODULES o 0 0 120%OF THE BUSBAR RATING V OFTOP BRANCH CIRCUIT#1.1 RO — — — — — — m ATTIC �� I p TO LOADSHOUSE < 1"FMC �� I EMT TRANSITION TO FMC (2)#30 AWG TH WN-2 CONDUCTOR BREAKERS SHALL BE INSIDE ATTIC(TYP.) (1)#10 AWG THWN-2 END INSTALLED OPPOSITE I (n SEE FIGURE A IN SOLAR E2 INSTALLED IN WALL CAVITY END OF THE MAIN BREAKER I z 1-FMC 0 (2)#30 AWG THWN-2 CONDUCTOR (1)#10 AWG THWN-2 GND F I ,ISA,2P ONI SUNPOWER Fti IL MONITORING 120A, PVS5X LL3 II L CATS¢ z0 L- - --- - - - - - - - - - - - LACK WIRE E r N L2 Ll ETHERNET CONNECTION B w RED WIR GND J p .ARE CU WIRE - - - - - - TO DSL/CABLE — MODEM AW 1/2'FMC (2)*14 G THWN-2 FIGURE C: ELECTRICAL CALCULATIONS EXISTING CONDUCTORS GND (1)#14 AWG THWN-2GND AC BRANCH 1 UTILITY-LOCKABLE SAFETY SWITCH 30A,240VAC IN WALL CAVITY OPPORTUNITY 007942 CUTLER-HAMMER DG221URB OR EQUIVALENT ROOF JCT BOX TO SUB-PANEL WIRING•BRANCH I MO LOCATED OUTSIDE WITH VISIBLE KNIFE BLADES REFER AC DISCONNECT SPECIFICATION-SOLAR-E3 SHEET NUMBER OF MODULES PER BRANCH CIRCUIT 12 PROJECT D-0053493 VOLTAGE 240 V BRANCH CURRENT'IOITT= 15.96A DATE DRAWN 06-14-2016 MINIMUM WIRE AMPACITY:IMAX=IOUT X 1.25 19.95 A CONDUCTOR DE-RATING MAXIMUM AM8IENT TEMPERATURE 40°C DRAWN BY MMENDOZA TEMPERATURE DE-RATING COEFFICIENT 0.91 FILL DE-RATING COEFFICIENT 1.0 DATE CHECKED 0fi-14-2016 WIRE_MIN=IMAX/TEMP_COEFF I FILL_COEFF 21.92A CONDUCTOR SIZE PER NEC #10 CHECKED BY EE-GBFS CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10 VOLTAGE DROP AT 85 FT DISTANCE 1319: OVERCURRENT PROTECTION 20A,2P NOT TO SCALE MINIMUM OCPD=IOUT X 125 19.95 A NEXT LARGER OCPD SIZE 20 A SHEET SOLAR-E1.3 C� E€ FIGURE A: THREE LINE DIAGRAM - 4.02 kWDC = w = v pow O H Ul m o m F� FIGURE B: LABELING SPECIFICATIONS ; Y ELECTRICAL NOTES m ¢ m W 3 ¢ o z u w >3 1. ALL SEAL TIGHT FLEXIBLE METAL CONDUIT(OR EQUIVALENT)TO BE BONDED TO GROUND AT WARNI COUPLINGS ON BOTH ENDS. �" O O m m N F ELECTR Cn_SHOCK I IAZA47 DO NOT-OUC-I Z _ ILRMINALS o j 2. CONDUIT ENTRY/CONNECTION TO ELECTRICAL ENCLOSURES SHALL BE SUITABLE FOR GROUNDING IH.TF RMINAI S 12AI:O'ES MAY 9=ENERG ON BOTH�Z-DTI IC I LINE AND � Q m O z N THE I w AND SHALL BE SEALED AGAINST ENVIRONMENT,SUCH AS WATER,INSECTS AND RODENTS.CONDUIT OPEN POS-IDN. ¢ ,u, €u SHALL NOT ENTER FROM TOP OF ELECTRICAL EQUIPMENT IN OUTDOOR LOCATIONS WITHOUT Z 2 =O SITE SPECIFIC APPROVAL FROM SUNPOWER.IF GRANTED APPROVAL FOR TOP ENTRY,ONLY RIGID JUNC'.Cn Hox a, V ¢ e g CONDUIT WITH MEVERS HUBS TO BE USED. O u PV A DIS ONNCCT U V 3. INSULATED BONDING BUSHINGS TO BE USED ON ALL CONDUIT TERMINATIONS REGARDLESS OF RA RATED OJLL F RE 15.9 CONK=.C"EU ,A VOLTAGE.THE INSULATING FITTINGS SHALL BE SUITABLE FOR BONDING ME GROUND IN RATED AC OJT:'J-CURRENT 15.96 A v, 0 ACCORDANCE WITH NEC 250.92.INSULATED BOX CONNECTORS DO NOT MEET THIS REQUIREMENT. AC IJISCON NECT EQ \^NINAI 01 FRAIInG AC VOLTAGE:240 V - 4. PROPER LISTING EXPECTED FOR CONDITIONS OF USE ON ALL LUGS,FITTINGS,CRIMPS,ETC. 5. ALL CONDUIT BEND RADII TO CONFORM TO THE NEC MINIMUM BEND RADII REQUIREMENTS. -- -__7 �n wgRwvc oun_ PCVT SOU�c_s fESS/ 6. MINIMUM CLEARANCE SHALL BE MAINTAINED PER NEC FOR ALL NEW EQUIPMENTS TO BE INSTALLED. w'ARNIVG. INVI-RTER OJ-PUT CONNECTION, C`~ DO NO! RLIOCATE THIS I 49 Yy, S/q 7. EXISTING GROUNDING ELECTRODE SYSTEM MUST MEET NEC AND LOCAL UTILITY REQUIREMENTS. OVERCJRRENT DEVICE A. CAUIION_ POWER TO-1 IS 3U LDINC IS n 8. COPPER CONDUCTORS SHALL BE USED UNLESS SPECIFIED. AI SO SUPPI.IED FROM THE IOLLO SOURCES _OCATEE OWN v ns sllowN. DW.o6-s1-1e 9. AC WIRING SHALL BE UPSIZED IF VOLTAGE DROP EXCEED 2%. 10.PV SYSTEM COMBINER PANEL SHALL BE USED ONLY WHEN PV PRODUCTION METER IS REQUIRED BY I PLAaJE nDlcgnNc so..RCLs � `f CTRI�P \P : 9 THE UTILITY.IF METER IS NOT REQUIRED,PV SYSTEM BREAKERS CAN BE DIRECTLY INTERCONNECTED MA S.CL .N A4 V: 15.96 A, 240 V ��1\ TO THE EXISTING SUB-PANEL OR MAIN PANEL. SEZ O L Y GPI,- 200A,240V PANEL 11.TYPE NM-B CONDUCTORS(ROMEX)SHALL NOT BE USED FOR EXTERIOR APPLICATION.IT SHALL BE USED ONLY INSIDE ATTIC AND IN WALL CAVITY. 12.RATING OF THE MAIN CIRCUIT BREAKER MAY VARY.IN ANY CASE,SUM OF THE MAIN BREAKER AND PV BREAKER MUST NOT EXCEED 120%OF THE BUS BAR RATING OF THE MAIN SERVICE PANEL. Z RE=ERENCFS:AI. RLGI.IR=VEN S ARE M=-BY: **2013 CALIFORNIA ELECTRICAL CODE(GEC)** Q NOTES: U a ry TI oTE: WHEN A BACKFED BREAKER IS THE METHOD OF UTILITY INTERCONNECON, LL z AS DC POWER IS INTERNAL BREAKER SHALL NOT READ"LINE AND LOAD". o U TO THE MODULE,GROUNDING J V LU ELECTRODE CONDUCTOR(GEC)FOR AC MoouLE GROUND FAULT PROTECTION IS REQUIRED FOR ROOF MOUNTED ARRAYS. W u Q (af) THE MODULE OR ARRAY IS NOT EXTENSION CABLE REQUIRED. INSTALL REFER TO GROUNDING DETAILS IN END CAP El PLAQUES SHALL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERS, o C) SHEET SOLAR-E3. JUNCTION BOX OR ELECTRO-PHOTO PLATING,IN A CONTRASTING COLOR TO THE PLAQUE.PLAQUE SHALL O y 1 (TRANSITION BOX) BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS. N J SUNPOWER MODULES Z) rl w ALL SIGNAGE IS TO BE RED BACKGROUND WITH WHITE LETTERS. (n In SPR-X21-335-BLK-C-AC INCOMING SOURCE FEED g 1 < (NOT CENTER-FED) INTEGRATED MICROINVERTER, 2 AC MODULES o 0 o CAUTION SOLAR CIRCUIT LABELS TO BE INSTALLED EVERY IW AND WITHIN 1'OF ALL TURNS, k M MI-c-3zD-usz08/240a/2aD-xx-uL 1741 BRANCH CIRCUIT#l.z _ _ Ro_Fro_ _ _ _ _ _ BENDS&PENETRATIONS. Q � M W • • . ATTIC CAUTION SOLAR CIRCUIT LABELS TO ALSO BE REFLECTIVE WHEN INSTALLED IN THE BUILDING ATTIC&ON ROOFTOP. N 1"FMC W (2)z10 AWG THwrv-2 corvoucroR A DIRECTIONAL PLACARD IS RE UIRED,NEEDS TO SHOW LOCATION OF PANELS, J ITY 1 a/ of(1)#30 AWG THWN-2 GND DISCONNECT,&ALL ELECTRICALL EQUIPMENT. a[D[RE METER Ur = \ �'YZ�12) CURRENTTRANSFORMERSDOOA) � ut 'Va / 1/ FMCAC MODULE *22 AWG TWISTED PAIR f m \\ EXTENSION CABLE 0 U INSTALL \ w w END CAP ' JUNCTION BOX MAIN ELECTRICAL PANEL N "O J (TRANSITION BOX) 140/120V,200A(MIN), 1 MCB O o K w UTILITY POINT OF INTERCONNECTION 1 Op SUNPOWER MODULES m j J 200A,2P 3 THE PROTECTION OVER CURRENT PROTECTION CANNOT EXCEE 10 AC MODULES D PR-X 1- 5-BLK--A 120%OF THE BUSBAR RATING U BRANCH CIRCUIT#1.1 ROOFTOP \ • • • ATTIC a\ In TO HOUSE LOADS t�\ O 1"FMC _ EMT TRANSITION TO FMC (2)#10 AWG THWN-2 CONDUCTOR BREAKERS SNAIL BE (1)#10 AWG THWN-2 GND INSTALLED OPPOSITE INSIDE ATTIC(TYP.) (n SEE FIGURE A IN SOLAR E2 INSTALLED IN WALL CAVITY END OF THE MAIN BREAKER Q I"FMC (2)#10 AWG THWN-2 CONDUCTOR (1)#10 AWG THWN-2 GND A'2P (n /\ SVNPOWER MONITORING 201 PVS5X w L — — — — — — — —. CATSe O —..— —..—..—..— —..—.. .. . RED WI0.E� — —.— INL2 ll ETHERNET — — — BLACK WIRE r CONNECTION BARE CU WIRE GND_ _ _ _ _ TO DSL/CABLEFIGURE C: O MODEM L J w (2)#14 AWG THWN-2 K RICALCULATIONS ' 1 Ex[snrvG CONDUCTORS —GND (1)#14AWGTHWN-2GND AC,BRANCH 1 UTILITY-LOCKABLE SAFETY SWITCH 30A,240VAC IN WALL cAVm OPPORTUNITY 007942 CUTLER-HAMMER DG221URB OR EQUIVALENT ROOF JCT BOX TO SUB-PANEL WIRING-BRANCH 1 #10 LOCATED OUTSIDE WITH VISIBLE KNIFE BLADES NUMBER OF MODULES PER BRANCH CIRCUIT 12 REFER AC DISCONNECT SPECIFICATION-SOLAR-E3 SHEET _ PROJECT D-0053493 VOLTAGE 240V BRANCH CURRENT'OUT= 15,96A' MINIMUM WIRE AMPACITY:IMAX-IOUTx 125 19.95A DATE DRAWN 06-14-2016 CONDUCTOR DE-RATING MAXIMUM AMBIENT TEMPERATURE 40-C DRAWN BY MMENDOZA TEMPERATURE DE-RATING COEFFICIENT 0.91 _ FILL DE-RATING COEFFICIENT 1.0 - �IIWIRE_MIN=1MAX/TEMP_COEFF/FILL_COEFF 21.92A DATE CHECKED 06-14-2016 CONDUCTOR SIZE PER NEC #10 CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10 CHECKED BY EE-GBFS VOLTAGE DROPAT 55 FT DISTANCE i.A1 0 OVERCURRENT PROTECTION 20A,2P'. NOT TO SCALE 'MINIMUM OCPD=10UTn 1.25 19.95 A' NEXT LARGER OCPO SIZE 20 A SHEET SOLAR-E1.4 E€ FIGURE A: THREE LINE DIAGRAM - 5.03 kWDC In F- H. ELECTRICAL NOTES FIGURE B: LABELING SPECIFICATIONS a m a o . u a c� 1. ALL SEAL TIGHT FLEXIBLE METAL CONDUIT(OR EQUIVALENT)TO BE BONDED TO GROUND AT O , COUPLINGS ON BOTH ENDS. WARNINGE ECTRICAL SHOCK HAZARD DO NOT TOUCH F O Z m ZF LHM IIALS. TERMINALS ON UOTH THE LINE AND a m O p w 2. CONDUIT ENTRY/CONNECTION TO ELECTRICAL ENCLOSURES SHALL BE SUITABLE FOR GROUNDING THE oAD SIDES MAY BE ENERGIZED IN THE m AND SHALL BE SEALED AGAINST ENVIRONMENT,SUCH AS WATER,INSECTS AND RODENTS.CONDUIT '�_0=EN roSl?.Cn 7 C a= m w Z SHALL NOT ENTER FROM TOP OF ELECTRICAL EQUIPMENT IN OUTDOOR LOCATIONS WITHOUT ` SITE-SPECIFIC APPROVAL FROM SUNPOWER.IF GRANTED APPROVAL FOR TOP ENTRY,ONLY RIGID JUNCTION BOX m CONDUIT WITH METERS HUBS TO BE USED. 0 PV AC DISCONNECT U ti RR 3. INSULATED BONDING BUSHINGS TO BE USED ON ALL CONDUIT TERMINATIONS REGARDLESS OF CAI�.CN-. 1OI A4 -_FCTRIC SYSTEM CONNECTED E m VOLTAGE.THE INSULATING FITTINGS SHALL BE SUITABLE FOR BONDING TO GROUND IN AC DISCONNECT RATED AC OUTPUT CURRENT: 19.95 A ACCORDANCE WITH NEC 250.92.INSULATED BOX CONNECTORS DO NOT MEET THIS REQUIREMENT. NOMINAL OPERATING AC VOLTAGE:240 V 5 4. PROPER LISTING EXPECTED FOR CONDITIONS OF USE ON ALL LUGS,FITTINGS,CRIMPS,ETC. 5.ALL CONDUIT BEND RADII TO CONFORM TO THE NEC MINIMUM BEND RADII REQUIREMENTS. WARNING DUAL POWER SOURCES �pfESS/ 6. MINIMUM CLEARANCE SHALL BE MAINTAINED PER NEC FOR ALL NEW EQUIPMENTS TO BE INSTALLED. WARNING: INVERTER OUTPUT CONNECTION, Do NOT RE'OCATE THIS gyp, Slq/„ 7. EXISTING GROUNDING ELECTRODE SYSTEM MUST MEET NEC AND LOCAL UTILITY REQUIREMENTS. OVERCURREC-DEVICE 'tR CAUTION: POWEH IO THIS BUILDING IS y `P 8. COPPER CONDUCTORS SHALL BE USED UNLESS SPECIFIED. ALSU SU==_IED FROM T9E FOL CWI NG SOURCES LOCATED � 9.AC WIRING SHALL BE UPSIZED IF VOLTAGE DROP EXCEED 2%. AS SOWN E.W41-18 PLAQUE INDICATING SOURCESfgTp1GP \P 10.PV SYSTEM COMBINER PANEL SHALL BE USED ONLY WHEN PV PRODUCTION METER IS REQUIRED -SOLAR PV: 19.95 A.240 V 'r OF(%�Q THE I IF METER IS NOT REQUIRED,PV SYSTEM BREAKERS CAN BE DIRECTLY INTERCONNECTED MAIN -UTILITY GRID:200A,24DV TO THEHE EXISTING TING SUB-PANEL OR MAIN PANEL. SERVICE PANEL 11.TYPE NM-B CONDUCTORS(ROMIX)SHALL NOT BE USED FOR EXTERIOR APPLICATION.IT SHALL BE USED ONLY INSIDE ATTIC AND IN WALL CAVITY. 12.RATING OF THE MAIN CIRCUIT BREAKER MAY VARY.IN ANY CASE,SUM OF THE MAIN BREAKER AND PV BREAKER MUST NOT EXCEED 120%OF THE BUS BAR RATING OF THE MAIN SERVICE PANEL. Z REFERENCES:ALL REQUIREMENTS ARE MET BY. Q **2013 CALIFORNIA ELECTRICAL CODE(CEC)** N NOTES: m U a LL NOTE: WHEN A BACKFED BREAKER IS THE METHOD OF UTILITY INTERCONNECTION, � AS DC POWER IS INTERNAL BREAKER SHALL NOT READ'LINE AND LOAD". O ,,`` U TO THE MODULE,GROUNDING J = V 0.LU ELECTRODE CONDUCTOR(GEC)FOR AC MODULE GROUND FAULT PROTECTION IS REQUIRED FOR ROOF MOUNTED ARRAYS. S Q (p THE MODULE OR ARRAY IS NOT EXTENSION CABLE ui REQUIRED. INSTALL PLAQUES SHALL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERS, 00 V a� REFER TO GROUNDING DETAILS IN ENO CAP JUNCTIN BOXSHEET SOLAR-E3. (TRANS ON BOX) OR ELECTRO-PHOTO PLATING,IN A CONTRASTING COLOR TO THE PLAQUE.PLAQUE SHALL N N Y BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS. _ ON w J Q SUNPOWER MODULES ¢¢ U)ALL SIGNAGE IS TO BE RED BACKGROUND WITH WHITE LETTERS, M Y m CO SPR-X21-335-BLK-C-AC ❑ ❑ ❑ INC(NOT CENTETEOMING RCER-FED)) g U N INTEGRATED MICROINVBLTER, 7 AC MODULES c c CAUTION SOLAR CIRCUIT LABELS TO BE INSTALLED EVERY 10'AND WITHIN 1'OF ALL TURNS, Q M MI-C-320-US208/240-XX-UL 1741 BRANCH CIRCUIT#2 ROOFTOP — — — — BENDS&PENETRATIONS. M W Z R R A I CAUTION SOLAR CIRCUIT LABELS TO ALSO BE REFLECTIVE WHEN INSTALLED IN THE BUILDING r r Q ATTIC&ON ROOFTOP. I �+ W A DIRECTIONAL PLACARD IS REQUIRED,NEEDS TO SHOW LOCATION OF PANELS, UTILITY- } 1 Lu DISCONNECT,&ALL ELECTRICAL EQUIPMENT. BIDIRECTIONAL I ` 11 I (r) a = METE0. CURRENTTRANSFORMERS(100A) Om ,A \ Y'J 1/T G T I � I� \ (z)CONDUCTORS U \ \ \ 1 CONDUCTORS AC MODULE I ()#14 AWG THWN-2 END \\ EXTENSION CABLE IN WALL CAVITY 0 _ INSTALL \\ EMT TRANSITION TO FMC I = U b \ I AC SUB-PANEL(rnJ w0 W Iu W END CAP INSIDE ATTIC 40A,120/240V,IPH MAIN ELECTRICAL PANEL .+C SEE FIGURE A iN SOLAR E2 m J 1/2"FMC UTILITY POINT OF INTERCONNECTION 1 1 MCB I 0 0 W SUNPOWER MODULES (2)#22 AWG TWISTED PAIR THE COMBINED OVER CURRENT J J 200A,2P I 3 a SPR-X21-335-BLK-C-AC ❑ I I I PROTECTION CANNOT EXCEED V o 0 o I 120%OF THE BUSBAR RATING 8 AC MODULES C BRANCH CIRCUIT#1 SUNPOWER • • • I MONITORING PVSSX 1"FMC I NSA,2P TO HOUSE (2)#10 AWG THWN-2 CNDUCTOR I I I C LOADS (1)#10 AWG THWN-2 END I CATS. OPTIONAL 1'FMCE MAIN (2)*10 AWG THWN-2 CONDUCTOR � 20A,2P r II ETHERNET CONCONNECTIONBREAKERS SHALL BE TO DSUCABLE MODEM INSTALLED AWG THWN-2 GND INSTALLED THE I (n �\ I INSTALLED IN WALL CAVITY END OF THE Z j I I I o 20A,2P I I I N 25A,2P LU L — L — — — — — — — T-I� GND INL2 L J INL2 L1 U BLACRED KI R RE WREE I END O W J BA WHITE WERE WRITE WIRE FIGURE C: ELECTRICAL CALCULATIONS — — — — J EXISTING —GND AC,BRANCH 1 AC,BRANCH 2 AC,SUB-PANEL UTILITY-LOCKABLE SAFETY SWITCH 30A,24OVAC OPPORTUNITY 007942 CURER-HAMMER DG221URB OR EQUIVALENT ROOF JOT BOX TO SUB-PANEL WIRING-BRANCH 1 910 ROOF JCT BOX TO SUB-PANEL WIRING-BRANCH 2 1H0 SUB-PANEL TO GRID-TIE WIRING 910 LOCATED OUTSIDE WITH VISIBLE KNIFE BLADES REFER AC DISCONNECT SPECIFICATION-SOLAR-E3 SHEET _ NUMBER OF MODULES PER BRANCH CIRCUR 0 NUMBER OF MODULES PER BRANCH CIRCUIT 7 VOLTAGE 240 V PROJECT D-0053493 _ VOLTAGE 240 V VOLTAGE 240 V SUM OF BRANCHES:IOUTTOTAL= 19.95 A 9 BRANCH CURRENT TOUT• 10-64A BRANCH CURRENT:POUT= 9.31A MINIMUM WIRE AMPACITY_[MAX=IOUTx 125 24.94A MINIMUM WIRE AMPACNY:IMAX=CUT x 125 1330A MINIMUM WIRE AMPACITY:IMAX=MIT x 125 11.64A CONDUCTOR DE4Uknw DATE DRAWN 06-14-2016 CONDUCTOR DE-RATING CONDUCTOR DEAATNG MAXIMUM AMBIENT TEMPERATURE 40'C MAXIMUM AMBIENT TEMPERATURE 40'C MAXIMUM AMBIENT TEMPERATURE 4010 TEMPERATURE DE-RATING COEFFICIENT 0.88 DRAWN BY MMENDOZA _ TEMPERATURE DE-RATING COEFFICIENT 0.91 TEMPERATURE DE-RATING COEFFICIENT 0.91 FILL DE-RATING COEFFICIENT 1.0 FILL DE-RATING COEFFICIENT 1.0 FILL DE-RATING COEFFlOBrr 1.0 MINE_MIN=IMAX I TEMP_COEFF/FdLCOEFF 28.34A DATE CHECKED 06-14-2016 IWIRE_MIN=IMAX/TEMP_COEFF I FILL_COEFF 14.52A WIRE_MIN-IMAX I TEMP_COEFF/FILL_COEFF 12.79A CONDUCTOR SIZE PER NEC #10 CONDUCTOR SIZE PER NEC #10 CONDUCTOR SIZE PER NEC #10 CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10 CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP 910 CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10 VOLTAGE DROP AT 5 FT DISTANCE 122% CHECKED BY EE-GBFS VOLTAGE DROP AT 85 FT DISTANCE 1.22% VOLTAGE DROP AT 85 FT DISTANCE 1.05% OVERCURRENT PROTECTION 25A,2P OVERCURRENT PROTECTION 20A,2P OVERCURNENT PROTECTION 2M,2P MINIMUM OCPD=IOUTx 125 I 24.94A NOT TO SCALE _ MINIMUM OCPD="IT x 1,25 13.30A MINIMUM OCPD=KIUTx 125 11A4A NEXT LARGER OCPD SIZE 25A NEXT LARGER OCPD SIZE 20A NEXT LARGER OCPD SIZE 20A SHEET SOLAR-E1.5 pC �a FIGURE A: THREE LINE DIAGRAM - 5.03 kWDC W ,� m <m m � 8 ELECTRICAL NOTES FIGURE B: LABELING SPECIFICATIONS ; ` N a F In3 < ? ; �m 1. ALL SEAL TIGHT FLEXIBLE METAL CONDUIT(OR EQUIVALENT)TO BE BONDED TO GROUND AT O u o w D COUPLINGS ON BOTH ENDS. WARNING' p p a ut ,ELECTRICAL SHOCK HAZARD.DO NOT TOUCH F O= KO _ g TERMINALS.TERMINALS ON BOTH THE LINE AND < m O p w IL$p 2. CONDUIT ENTRY/CONNECTION TO ELECTRICAL ENCLOSURES SHALL BE SUITABLE FOR GROUNDING THE LOAD SIDES MAY BE ENERGIZED IN THE a •X i .. w Eg B AND SHALL BE SEALED AGAINST ENVIRONMENT,SUCH AS WATER,INSECTS AND RODENTS.CONDUIT OPEN POSITION. < SHALL NOT ENTER FROM TOP OF ELECTRICAL EQUIPMENT IN OUTDOOR LOCATIONS WITHOUT n SITE-SPECIFIC APPROVAL FROM SUNPOWER.IF GRANTED APPROVAL FOR TOP ENTRY,ONLY RIGID JUNCTION BOX •: v •u" < E CONDUIT WITH MEYERS HUBS TO BE USED. 3. INSULATED BONDING BUSHINGS TO BE USED ON ALL CONDUIT TERMINATIONS REGARDLESS OF PV AC DISCONNECT U w y VOLTAGE.THE INSULATING FITTINGS SHALL BE SUITABLE FOR BONDING TO GROUND IN CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED AC DISCONNECT RATED AC OUTPUT CURRENT. 19.95 A v ACCORDANCE WITH NEC 250,92.INSULATED BOX CONNECTORS DO NOT MEET THIS REQUIREMENT. NOMINAL OPERATING AC VOLTAGE:240 V 4. PROPER LISTING EXPECTED FOR CONDITIONS OF USE ON ALL LUGS,FITTINGS,CRIMPS,ETC. 5.ALL CONDUIT BEND RADII TO CONFORM TO THE NEC MINIMUM BEND RADII REQUIREMENTS. WARNING:DUAL POWER SOURCES ��In1fESS/ 6. MINIMUM CLEARANCE SHALL BE MAINTAINED PER NEC FOR ALL NEW EQUIPMENTS TO BE INSTALLED. WARNING:INVERTER OUTPUT CONNECTION, Y`~ DO NOT RELOCATE THIS 7. EXISTING GROUNDING ELECTRODE SYSTEM MUST MEET NEC AND LOCAL UTILITY REQUIREMENTS. POWER TO THIS DEVICE CAUTION: POWER TO THIS BUILDING IS h S.COPPER CONDUCTORS SHALL BE USED UNLESS SPECIFIED. ALSO SUPPLIED FROM THE Y FOLLOWING SOURCES LOCATED 9.AC WIRING SHALL BE UPSIZED IF VOLTAGE DROP EXCEED 2%. 7.4:" AS SHOWN. * BP M-31-18 10.PV SYSTEM COMBINER PANEL SHALL BE USED ONLY WHEN PV PRODUCTION METER IS REQUIRED BY PLAQUE INDICATING SOURCES: �,9�FCTFOG' THE UTILITY.IF METER IS NOT REQUIRED,PV SYSTEM BREAKERS CAN BE DIRECTLY INTERCONNECTED MAIN -SOLAR PV: 19.95 A.240 V ,,CC OF CAL TO THE EXISTING SUB-PANEL OR MAIN PANEL. PANEL -UTILITY GRID-200A,240V 11.TYPE NI CONDUCTORS(ROMEX)SHALL NOT BE USED FOR EXTERIOR APPLICATION.IT SHALL BE USED ONLY INSIDE ATTIC AND IN WALL CAVITY. 12.RATING OF THE MAIN CIRCUIT BREAKER MAY VARY.IN ANY CASE,SUM OF THE MAIN BREAKER AND PV BREAKER MUST NOT EXCEED 120%OF THE BUS BAR RATING OF THE MAIN SERVICE PANEL. Z REFERENCES:ALL REQUIREMENTS ARE MET BY **2013 CALIFORNIA ELECTRICAL CODE(CEC)** N Q NOTES: rn U_ WHEN A BACKFED BREAKER IS THE METHOD OF UTILITY INTERCONNECTION, S LL AS DC POWER IS INTERNAL BREAKER SHALL NOT READ"LINE AND LOAD". U TO THE MODULE,GROUNDING J V W ELECTRODE CONDUCTOR(III FOR AO MODULE GROUND FAULT PROTECTION IS REQUIRED FOR ROOF MOUNTED ARRAYS. lY 4Q a THE MODULE OR ARRAY IS NOT EXTENSION CABLE LL.I (/) REQUIRED. INSTALL REFER TO GROUNDING DETAILS IN END CAP- PLAQUES SHALL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERS, p C,) 0-6 SHEET SOLAR-El JUNCTION BOX OR ELECTRO-PHOTO PLATING,IN A CONTRASTING COLOR TO THE PLAQUE.PLAQUE SHALL Fj Z 2:(TRANSIT-ION BOX) BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS. J SUNPOWER MODULES "--I ALL SIGNAGE IS TO BE RED BACKGROUND WITH WHITE LETTERS. m Q SPR-X21.335-BLK-C-AC INCOMING SOURCE FEED I (NOT CENTER-FED) INTEGRATED MICROINVERTER, 6 AC MODULES o CAUTION SOLAR CIRCUIT LABELS TO BE INSTALLED EVERY 10'AND WITHIN 1'OF ALL TURNS, M 0 MI-C-320-US208/240-XX-UL 1741 BRANCH CIRCUIT*2 • • • nmC D� BENDS&PENETRATIONS. EEL I z CAUTION SOLAR CIRCUIT LABELS TO ALSO BE REFLECTIVE WHEN INSTALLED IN THE BUILDING r J 1 FMC ATTIC&ON ROOFTOP. r ry W (2)*30 AWG THWN-2 CONDUCTOR A DIRECTIONAL PLACARD 1S REQUIRED,NEEDS TO SHOW LOCATION OF PANELS, UTILITY I^ I 7TG W (1)*30 AWG THWN-2 GND I DISCONNECT,&ALL ELECTRICAL EQUIPMENT. BIOIRECTf ETAL I I R� _ METER `` CURRENT TRANSFORMERS(100A) N V! J \ I 1/2"G THWN-2 Q W Q (2)CONDUCT C, \ \ AC MODULE (1)*14 AWGT GND i �qOf \� EXTENSION CABLE IN WALL CAVITY p U� INSTALL \ I AC SUB-PANEL(TYP.) S K yI b END CAP JUNCTION BOX 40A,120/240V,iPH MAIN ELECTRICAL PANEL upXA J (TRANSITION BOX) -._ 240/120V,200A(MIN),I p o W I� 1/2"FMC UTILITY POINT OF INTERCONNECTION MCB O m (2)*22 AWG TWISTED PAIR THE COMBINED OVER CURRENT 200A,2P O SUNPOWER MODULES ; .. PROTECTION CANNOT EXCEED SPR-X21-335-BLK-C-AC 120%OF THE BUSBAR RATING I I u 9 AC MODULES o 0 0 RDOFTOP WIC.ATSe �� m BRANCH CIRCUIT*1 p • • • ATTIC IMONITORING 15A,2P T LOADS HOUSE OPTIONAL I-FMC EMT TRANSITION TO FMC 20A,2P I ETHERNET CONNECTION (2)*10 AWG TH N 7 CONDUCTOR BREAKERS SHALL BE INSIDE ATTIC.MR) �\ � - J TO DSVCABLE MODEM INSTALLED N WALL 2 END END OF THE MAIN � SEE FIGURE A IN SOLAR E2 INSTALLED OPPOSITE �\ BREAKER O 1"FMC (2)*10AWGTHWN-2CDNDUCMR - Oti (1)*10 AWG THWN-2 GND --�r 20�\I I N I I I I � `.• I > 25 2P I UJ L — — — — —T-III I -. - - - ND G N L2 L, I I OC i h BLACK WIRE rl. GND RED WIRE BARE CU WIRE WHITE WIRE J Ir FIGURE C: ELECTRICAL CALCULATIONS — — — EXISTING -GND D,SRANCH 1 D,BRANCH 2 AG,SU&PANEL UTILITY-LOCKABLE SAFETY SWITCH 30A,240VAC OPPORTUNITY 007942 CUTLER-HAMMER DG221URB OR EQUIVALENT ROOF JCT BOX TO SUB-PANEL WIRING-BRANCHI *10 ROOF JCT BOX TO SU"ANEL WIRING-BRANCH 2 *10 SUB-PANEL TO GRIDME WIRING MO LOCATED OUTSIDE WITH VISIBLE KNIFE BLADES REFER AC DISCONNECT SPECIFICATION-SOLAR-E3 SHEET NUMBER OF MODULES PER BRANCH CIRCUIT 0 NUMBER OF MODULES PER BRANCH CIRCUIT S VOLTAGE 240 V PROJECT D-0053493 VOLTAGE 240 V VOLTAGE 240 V SUM OF BRANCHES:IOUT-TOTAL• 19.95 A BRANCH CURRENT:TOUT- 11.97A BRANCH CURRENT:OUT T.NA MINIMUM WIRE AMPACITY:IMAX•IDUT x 1.25 24.94A MINIMUM WIRE AMPDITY:IMAX•IOUTx 1.26 14.9BA MINIMUM WIRE AMPACMY:MAX•IOUT x 125 111 CONDUCTOR DE4TA7ING DATE DRAWN 06-14-2016 CONDUCTOR DE4IATING CONDUCTOR DE4RATING MAXIMUM AMBIENT TEMPERATURE 4WC MAXIMUM AMBIENT TEMPERATURE 40"C MAXIMUM AMBIENT TEMPERATURE 40-C TEMPERATURE DE-RATING COEFFICIENT 0.88 DRAWN BY MMENDOZA TEMPERATURE DE-RATING COEFFICIENT 0.91 TEMPERATURE DE-RATING COEFFICIENT 0A1 FILL DE-RATING COEFFICIENT 110 FILL DE-RATING COEFFICIENT 1.0 FILL DE-RATING COEFFICIENT 1.0 WIREMIN•IMAX/TEMPOOEFF I FILLCOEFF 28.34A DATE CHECKED 06-14-2016 IWIRE_MIN•IMAX/TEMP_COEFF/FILL_COEFF 18A4A IWIRE MIN=IMAX/TEMP_COEFF/FILL-COEFF 10.06A CONDUCTOR SIZE PER NEC *10 CONDUCTOR SIZE PER NEC 010 CONDUCTOR SIZE PER NEC 010 CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP 010 CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP III CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP 010 VOLTAGE DROP AT 5 FT DISTANCE 1.39% CHECKED BY EE-GBFS VOLTAGE DROP AT 85 FT DISTANCE 1.39% VOLTAGE DROP AT 85 FT DISTANCE 0.91% OVERCURRENT PROTECTION 212P OVERCURRENT PROTECTION 20A,2P OVERCURRENT PROTECTION III 2P MINIMUM OCPD•IOUI 1.25 24.04A NOT TO SCALE MINIMUM OCPD•IOITx 1.25 14.9BA MINIMUM OCPD•IOUTx 125 BABA NEXT LARGER OCPD SIZE 25 A NEXT LARGER OCPD SIZE 20 A NEXT LARGER OCPD SIZE 20 A SHEET SOLAR-E1.6 E� FIGURE A: THREE LINE DIAGRAM - 5.03 kWDC W f a s w 0. m ELECTRICAL NOTES FIGURE B: LABELING SPECIFICATIONS 1. ALL SEAL TIGHT FLEXIBLE METAL CONDUIT(OR EQUIVALENT)TO BE BONDED TO GROUND AT WARNING O a w B COUPLINGS ON BOTH ENDS. ELECTRICAL SHOCK HAZARD DO NOT TOUCH f O Z A Z lip TERMINALS.TERMINALS ON BOTH THE LINE AND c m p g 2. CONDUIT ENTRY/CONNECTION TO ELECTRICAL ENCLOSURES SHALL BE SUITABLE FOR GROUNDING THE LOAD SIDES MAY BE ENERGIZED IN THE y a a O AND SHALL BE SEALED AGAINST ENVIRONMENT,SUCH AS WATER,INSECTS AND RODENTS.CONDUIT OPEN POSITION SHALL NOT ENTER FROM TOP OF ELECTRICAL EQUIPMENT IN OUTDOOR LOCATIONS WITHOUT u _u B SITE-SPECIFIC APPROVAL FROM SUNPOWER.IF GRANTED APPROVAL FOR TOP ENTRY,ONLY RIGID JUNCTION BOX W ti CONDUIT WITH MEYERS HUBS TO BE USED. � O u v � 3. INSULATED BONDING BUSHINGS TO BE USED ON ALL CONDUIT TERMINATIONS REGARDLESS OF EN-OMINAL NNECT yl LAR ELECTRIC SYSTEM CONNECTED E VOLTAGE.THE INSULATING FITTINGS SHALL BE SUITABLE FOR BONDING TO GROUND IN TPUT CURRENT: 19.95 A B ACCORDANCE WITH NEC 250.92.INSULATED BOX CONNECTORS DO NOT MEET THIS REQUIREMENT. AC DISCONNECT RATING AC VOLTAGE:240 V io 4. PROPER LISTING EXPECTED FOR CONDITIONS OF USE ON ALL LUGS,FITTINGS,CRIMPS,ETC. S. ALL CONDUIT BEND RADII TO CONFORM TO THE NEC MINIMUM BEND RADII REQUIREMENTS. WARNING:DUAL POWER SOURCES �FESS/a4 6. MINIMUM CLEARANCE SHALL BE MAINTAINED PER NEC FOR ALL NEW EQUIPMENTS TO BE INSTALLED. WARNING:INVERTER OUTPUT CONNECTION, DO NOT RELOCATE THIS 7. EXISTING GROUNDING ELECTRODE SYSTEM MUST MEET NEC AND LOCAL UTILITY REQUIREMENTS. CAUTION: POWER OVERCPOWER RRENT DEVICE TO THIS BUILDING IS y a ALSO SUPPLIED FROM THE v B. COPPER CONDUCTORS SHALL BE USED UNLESS SPECIFIED. FOLLOWING SOURCES LOCATED AS SHOWN. UE.AA31-1e 9.AC WIRING SHALL BE UPSIZED IF VOLTAGE DROP EXCEED 2%. .7f * F PLAQUE INDICATING SOURCES: gFCTR IG�' �P 10.PV SYSTEM COMBINER PANEL SHALL BE USED ONLY WHEN PV PRODUCTION METER IS REQUIRED BY -SOLAR PV: 19.95 S 2RC V ,C QF�L�`Y� THE UTILITY.IF METER IS NOT REQUIRED,PV SYSTEM BREAKERS CAN BE DIRECTLY INTERCONNECTED MAIN I ILIN GRID 200A,240V TO THE EXISTING SUB-PANEL OR MAIN PANEL. SERVICE PANEL I 11.TYPE NM-B CONDUCTORS(ROMEX)SHALL NOT BE USED FOR EXTERIOR APPLICATION.IT SHALL BE USED ONLY INSIDE ATTIC AND IN WALL CAVITY. 12.RATING OF THE MAIN CIRCUIT BREAKER MAY VARY.IN ANY CASE,SUM OF THE MAIN BREAKER AND z PV BREAKER MUST NOT EXCEED 120%OF THE BUS BAR RATING OF THE MAIN SERVICE PANEL. O REFERENCES:ALL REQUIREMENTS ARE MET BY. **2013 CALIFORNIA ELECTRICAL CODE(CEC)** Q NOTES: U_ WHEN A BACKFED BREAKER IS THE METHOD OF UTILITY INTERCONNECTION, = LL NOTE: BREAKER SHALL NOT READ"LINE AND LOAD". J S /+W AS DC POWER IS INTERNAL U CL TO THE MODULE,GROUNDING AC MODULE AC MODULE GROUND FAULT PROTECTION IS REQUIRED FOR ROOF MOUNTED ARRAYS. w l� a U) ELECTRODE CONDUCTOR(GEC)FOR Q - THE MODULE OR ARRAY IS NOT EXTENSION CABLE EXTENSION CABLE REQUIRED. INSTALL INSTALL PLAQUES SHALL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERS, 0 °� 1 REFER TO GROUNDING DETAILS IN END CAP END CAP ? SHEET SOLAR-tl. JUNCTION BOX OR ELECTRO-PHOTO PLATING,IN A CONTRASTING COLOR TO THE PLAQUE.PLAQUE SHALL N Y (TRANSITION BOX) BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS. Z) 01 w J SUNPOWER MODULES SUNPOWER MODULES ALL SIGNAGE IS TO BE RED BACKGROUND WITH WHITE LETTERS. ul M x in INCOMING SOURCE FEED S R < SPR-X21-335-BLK-C-AC SPR-X21-335-BLK-C-AC (NOT CENTER-FED) 1 AC MODULES 10 AC MODULES CAUTION SOLAR CIRCUIT LABELS TO BE INSTALLED EVERY 10'AND WITHIN 1'OF ALL TURNS, Q M 0 INTEGRATED MICROINVBRTER, ROOFTOP BENDS&PENETRATIONS. F- M W MI-C-320-US208/240-XX-UL 1741 BRANCH CIRCUIT#2.1 BRANCH CIRCUIT#1 ATTIC r Q U Z CAUTION SOLAR CIRCUIT LABELS TO ALSO BE REFLECTIVE WHEN INSTALLED IN THE BUILDING r N J 1'FMC ATTIC&ON ROOFTOP. I r Ht x W (2)#10 AWG TM -2 CONDUCrOR A DIRECTIONAL PLACARD IS REQUIRED,NEEDS TO SHOW LOCATION OF PANELS, unLTR (1)#10 AWG THWN-2 GND BIDIRECTIONAL I I I (D DISCONNECT,&ALL ELECTRICAL EQUIPMENT. METER I CURRENT TRANSFORMERS(100 A \ I 1/2"FMC J N V/ J \ L _ (2)#14 AWG THWN-2 I t (� \ CONDUCTORS �N \ AC MODULE (1)414 AWG THWN-2 GND FF O Na EXTENSION CABLE IN WALL CAVITY = V INSTALL \\ AC SUB-PANEL(fYP.) p w0 W END CAP 4DA,120/24OV,IPH MAIN ELECTRICAL PANEL JUNCTION BOX J 290/120V,200A(MIN), n W (TRANSITION BOX) 1/2"PMC UTILITY POINT OF INTERCONNECTION 1 Mr O yu (2)*22 AWG TWISTED PAIR J 200A,2P I 3 a SUNPOWER MODULES THE COMBINED OVER CURRENT I PROTECTION CANNOT EXCEED SPR-X21-335-BLK-C-AC 120%OF THE BUSBAR RATING I I u 4 AC MODULES o 0 o I I I 4. -NAL BRANCH CIRCUIT#2.2 I ATTIC I /� O I5A,2P I TO LOADSVFMC HOUSE I I ^ (2)#30 AWG THWN2 CONDUCTOR BREAKERS SHALL BE ETHERNET CONNECTION (1)*IOAWG THWN-2GND INSTALLED OPPOSITE EMT TRANSITION TO R)4 20A,2P _ J TO DSL/CABLE MODEM INSIDE ATTIC.(TYP.) I ( �� T- INSTALLED IN WALL CAVITY END OF THE MAIN SEE FIGURE A IN SOLAR E2 i BREAKER I I O I (2)#10 AWG THWN-2 CONDUCTOR (I)*ID AWG THWN-2 GND I L- 2 2P LU o I L_ _ _ _..- _ _ _ _. _ _ _� GNDN L2 LI I I I C L — —..—— — -- - - - - -.._._.._..- - - - - - - - - a ._.._ - _ -r N L2 LI I w BLACK WIRE 'rll RED WIRE J GND G BARE CU WIRE WHITE WIRE FIGURE C: ELECTRICAL CALCULATIONS 1 EXISTING —GND AC,BRANCHI AC,BRANCH2 AC,SUB-PANEL UTILITY-LOCKABLE SAFETY SWITCH 30A,240VAC OPPORTUNITY 007942 CUTLER-HAMMER DG221URB OR EQUIVALENT ROOF JCT BOX TO SUB-PANEL WIRING-BRANCH 1 #10 ROOF JCT BOX TO SU"ANEL WIRING-BRANCH 2 #10 SUB-PANEL TO GRID-TIE WIRING MO LOCATED OUTSIDE SPECIFICATION LADES 0.EFE0.C DISCONNECT WITH ISIBLE -SOLAOLAR-tl SHEET _ NUMBER OF MODULES PER BRANCH CIRCUIT 10 NUMBER OF MODULES PER BRANCH CIRCUIT 5 VOLTAGE 240 V PROJECT D-0053493 VOLTAGE 240V VOLTAGE 240V SUM OF BRANCHES:IOUTTOTAL= 19.95A - BRANCH CURRENT:K)UT= 13,30A BRANCH CURRENT:IOUT= 6.65A MINIMUM WIRE AMPACITY:IMAX=10UTx 1.25 24.94A DATE DRAWN 06-14-2016 MINIMUM WIRE AMPACITY:IMAX=10UTx 125 10.63A MINIMUM WIRE AMPACITY:IMAX-OLTx 125 831A CONDUCTOR DE-RATING CONDUCTOR DE-RATING CONDUCTOR DEBATING MAXIMUM AMBIENT TEMPERATURE 40'C DRAWN BY MMENDOZA MAXIMUM AMBIENT TEMPERATURE 40'C MAXIMUM AMBIENT TEMPERATURE 40'C TEMPERATURE DE-RATING COEFFICIENT O88 TEMPERATURE DE-RATING COEFFICIENT 0.91 TEMPERATURE DE-RATING COEFFICIENT 0.91 FILL DE-RATING COEFFICIENT 1.0 _ FILL DE-RATING COEFFICIENT 1.0 FILL DE-RATING COEFFICIENT 1.0 WIRE_MIN=IMAX I TEMP_COEFF/FILLCOEFF 2634A DATE CHECKED 06-14-2016 IWIRE_MIN=IMAX/TEMP GOEFF I FILL_COEFF 1827A [WIRE-MIN=IMAX/TEMP COEFF I FILL_COEFF 9.13A CONDUCTOR SIZE PER NEC #10 CONDUCTOR SIZE PER NEC #10 CONDUCTOR SIZE PER NEC #10 CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10 CHECKED BY EE-GBFS CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10 CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10 VOLTAGE DROP AT 5 FT DISTANCE 1 56% VOLTAGE DROP AT 85 FT DISTANCE 1.56% VOLTAGE DROP AT 85 FT DISTANCE 0.76% OVERCURRENT PROTECTION 25A,2P OVERCURRENT PROTECTION20A.2P OVERCURRENTPROTECTION 20A,2P MINIMUM OCPD=IOUTx 121 21,NA NOT TO SCALE MINIMUM OCPD=OUT x 125 16.63A MINIMUM OCPD=10UT x 125 831A NEXT LARGER OCPD SIZE 25A SHEET NEXT LARGER OCPD SIZE 20A NEXT LARGER OCPD SIZE 20A SOLAR-Ell FIGURE A: WIRING ROOF PENETRATION CROSS SECTION FIGURE C: INTERIOR EQUIPMENT Lu m $ F 0 a m w 00 H In m w � � Q 3@ WALL STUDS > In m a o z m ° jo � w a @ m a mod w 1/4" ALUMINUM BRACKET ATTACHED TO m m f u � CONCRETE TILE 7 a a8 INVISIMOUNT RAIL BY 2 ® 1/2" BOLT L RAIL 6"x6"x6" N3 PVC JUNCTION BOX C aN o z u W9= u a �'^ CORD GRIP AC TRANSITION CABLE TO ACPV MODULE O �9QppFESS/ LIQUID TIGHT EMT CONNECTOR , V Y� S Ri I L �( _ aT . I" LB L J ESP 0341-18 AC DU D NINECT 91 De 'PJ,q FIFCiR\GQ��a�P ° ° I �pF CpL\P7' In fnI f/� ° ° ------ ------I U! IIYII�Y 18"X18" SPUN CONE FLASHING 9"X9" SPUN CONE 0 SUB FLASHING N UPPER AND LOWER COUNTER FLASHINGS TRIMMED FOR 1"EMT 1" EMT SECURE CONDUIT TO RAFTER S CONDUIT PER LOCAL BUILDING CODE. J o (CLIPS NOT INC-UDLD) 1" FMC W Q N NOTE: 04 ? U Q ALL CONDUITS AND WIRES TO BE Z) 0 w RELOCATED A MINIMUM OF 10" Ln BELOW THE ROOF DECK. NOTE: # rn Q X WORKING CLEARANCE IN FRONT Q U rI U FIGURE B: TYPICAL SCHEMATIC ARRAY LAYOUT OF THE INVERTER AC DISCONNECT X U ¢ w AND ELECTRICAL SERVICE PANELLf) H- a w INVISIMOUNT 0 N Z( END CLAMP Q N — o GS (( I I I ( � o obi �— I _ SUNPOWER AC g INVISIMOUNT MID CLAMP MODULE s PROVIDES INTEGRATED BONDING AND GROUNDING COMPLYING TO UL2703 T ` FIGURE D: EXTERIOR EQUIPMENT cn iU) > l 1 AC DISCONNECT W GROUNDING LUG — INVISIMOUNT RAIL 0 - u Zrr TLL INVISIMOUNT SPLICE � ( PROVIDES INTEGRATED RAIL OPPORTUNITY 007942 BONDING AND GROUNDING COMPLYING TO UL2703 PROJECT D-0053493 DRAWN ATE 6-14-2016 r l ( AC o N� D 0 I ( I U DE DRAWN BY MMENDOZA DATE CHECKED 06-14-2016 t \ CHECKED BY BE-GBFS NOTE: IN THE EVENT THAT A MODULE NEEDS TO BE REPLACED AND THE TARGET MODULES WILL BE OUT OF THE ARRAY FOR AN EXTENDED PERIOD OF TIME,CAREFULLY ATTACH TWO MID CLAMPS TO THE _ EXPOSED MODULE EDGE(NOTE THAT TWO OF THE TEETH OF THESE MID CLAMPS WILL INSTEAD DIRECTLY ENGAGE THE TOP OF THE RAIL). THE MID CLAMP WILL KEEP MODULES BONDED TO THE RAIL, ' NOT TO SCALE WHICH IS BONDED TO THE EQUIPMENT GROUNDING CONDUCTOR(EGC)AND IN TURN THE GROUNDED ELECTRODE CONDUCTOR(GEC) MAIN SEIZIVICE PI SHEET -AC CABLE GROUND PATH HAS BEEN TESTED BY NRTL,AND ITS ELECTRICAL CONTINUITY FROM THE AC CABLE GROUND PIN TO THE MODULE FRAME HAS BEEN CERTIFIED. -AC INTERCONNECTING CABLE SYSTEM ATTACHED TO EACH MODULE'S MICROINVERTER IS FULLY INSULATED AND INCLUDES AN INTERNAL EGC.THE GROUNDING PIN IS LONGER THAN THE OTHERS IN THE SOLAR-E2.1 PLUG.THIS EXTRA LENGTH ENSURES THAT THE GROUND IS THE FIRST TO MAKE CONTACT WHEN CONNECTING MODULES AND THE LAST TO BREAK CONTACT WHEN DISCONNECTING MODULES. -IF A MODULE IS REMOVED FROM A CIRCUIT FOR ANY REASON,INSTALL A TEMPORARY EGC TO BRIDGE THE GAP BY INSERTING AN AC EXTENSION CABLE OR OTHER MEANS TO MAINTAIN EFFECTIVE GROUND CONTINUITY TO SUBSEQUENT MODULES. FIGURE A: WIRING ROOF PENETRATION CROSS SECTION FIGURE C: INTERIOR EQUIPMENT LJ..1 N N r 1: » w 0. Oil WALL STUDS > 0 D a O e m 0 Si A r Z . Z Li m 1/4" ALUMINUM BRACKET ATTACHED TO z ac s u ,o CONCRETE TILE a INVISIMOUNT RAIL BY 2 ® 1/2" BOLT z o = x RAIL U 6"x6"x6" N3 PVC JUNCTION BOX m o uffi_ SUB PANEL u � CORD GRIP AC TRANSITION CABLE TO (n ACPV MODULE O u ,�ppFESs/qy LIQUID TIGHT EMT CONNECTOR r , e� a �Y SRC v L 1 LB E.m-31-18 N 0 0 OF CpL\ o o I I II I4 18"X18" SPUN COWE FLASHING 9"X9" SPUN CONE SUB FLASHING N UPPER AND LOWER COUNTER a FLASHINGS TRIMMED FOR 1"EMT 1" EMT SECURE CONDUIT TO RAFTER CONDUIT PER LOCAL BUILDING CODE. J (CLIPS NOT INCLUDED) 8 1" FMC W UQ o NOTE: ry U Q ALL CONDUITS AND WIRES TO BE w t RELOCATED A MINIMUM OF 10" U) cn 5 m o BELOW THE ROOF DECK. NOTE: H M Q 3'WORKING CLEARANCE IN FRONT Q In U OF THE INVERTER AC DISCONNECT Q .- o' FIGURE B: TYPICAL SCHEMATIC ARRAY LAYOUT AND ELECTRICAL SERVICE PANEL x Z) o Lu INVISIMOUNT U' N ` r i END CLAMP Q o It SUNPOWER AC INVISIMOUNT MID CLAMP --a MODULE 3 PROVIDES INTEGRATED .. , .,, ;. . .,._ : .., �.:, - .• B BONDING AND GROUNDING COMPLYING TO UL2703 E FIGURE D: EXTERIOR EQUIPMENT In ; I II II > I I I I I AC DISCONNECT w I Y Y �.�.� /' GROUNDING LUG — ` ' _,% _ —-_ T T INVISIMOUNT RAIL o bi I INVISIMOUNT SPLICE I ; l II j I• jl ; j PROVIDES INTEGRATED RAIL ' I ' ` i ' i i i -------r•1------� OPPORTUNITY 007942 BONDING AND GROUNDING I ( COMPLYING TO UL2703 ; �i}, PROJECT D-0053493 0 DRAWN ATE 6 14-2016 D ( —• r DRAWN BY MMENDOZA ------------- DATE CHECKED 06-14-2016 � I I � i CHECKED BY EE-GBFS NOTE: i ji � I ii l IN THE EVENT THAT A MODULE NEEDS TO BE REPLACED AND THE TARGET MODULES WILL BE OUT OF THE ARRAY FOR AN EXTENDED PERIOD OF TIME,CAREFULLY ATTACH TWO MID CLAMPS TO THE EXPOSED MODULE EDGE(NOTE THAT TWO OF THE TEETH OF THESE MID CLAMPS WILL INSTEAD DIRECTLY ENGAGE THE TOP OF THE RAIL). THE MID CLAMP WILL KEEP MODULES BONDED TO THE RAIL, I' i i NOT TO SCALE WHICH IS BONDED TO THE EQUIPMENT GROUNDING CONDUCTOR(EGC)AND IN TURN THE GROUNDED ELECTRODE CONDUCTOR(GEC) i' MAIN SE 1/ICE PAID L -AC CABLE GROUND PATH HAS BEEN TESTED BY NRTL,AND ITS ELECTRICAL CONTINUITY FROM THE AC CABLE GROUND PIN TO THE MODULE FRAME HAS BEEN CERTIFIED. ' ' I i SHEET -AC INTERCONNECTING CABLE SYSTEM ATTACHED TO EACH MODULE'S MICROINVERTER IS FULLY INSULATED AND INCLUDES AN INTERNAL EGC.THE GROUNDING PIN IS LONGER THAN THE OTHERS IN THE SOLAR-E2.2 PLUG.THIS EXTRA LENGTH ENSURES THATTHE GROUND IS THE FIRST TO MAKE CONTACT WHEN CONNECTING MODULES AND THE LAST TO BREAK CONTACT WHEN DISCONNECTING MODULES. ' -IF A MODULE IS REMOVED FROM A CIRCUIT FOR ANY REASON,INSTALL A TEMPORARY EGC TO BRIDGE THE GAP BY INSERTING AN AC EXTENSION CABLE OR OTHER MEANS TO MAINTAIN EFFECTIVE GROUND CONTINUITY TO SUBSEQUENT MODULES. LLaj _ s33x PLO, Oo o, H n doo 0° F a v m > 1.7 Grounding Overview ' a do @� Residential air W■mMal Ensure that you fully understand the grounding aspects in this section before proceeding. s U o un c ModuleX21-335-BLK-C-AC Residential AC - o m o N �yl H$ • The AC dedicated branch circuit wiring from the readily accessible disconnect to the array must include ^' C) g'-F SUnPOwerMonitoringWebSite -^JSSx SunPower AC Modules anequipmentgroundingconductor(EGQinthesameracewayorCableastheACcircuitconductors.This Q ad C, o w g Improve Support, Sun Power Monitoring Solution, -_ EGC must be connected to the green conductor of the transition cable,which is part of the AC module cables tem. Reduce Maintenance Costs Plug and Play Installation n SoRVI335911-C.AC SPR.A20327.Bu•'.0 AL Sold•Cells %MpPOLN-Rine Ma,eon+e Caen I g y r (� y= � ., Namnul- br§Pnc•r) 335 W 327 w l ilgn-trensmleslon rcmueretl x'ass•vri aou An inwitrw mummnng—hate enables you to The complete solution fc,lesIcenoai monnonng-lodes the ■ . If a module is removed from a circuit,Sunflower strongly recommends that you install a temporary EGC iron-lass sLrPcwfr•,^V Su rnAspr rx PVS5x)which lm pods the Installation ■ Muk,le communka[ion su SunPower%car O „ U vow«,rnlorw�rc «y too .V 0'0 ° reAa tac coaon¢ 5eeawsualmao of nnmeaxner sties p '( pr p gyp ' to bridge the gap by inserting an AC extension cable or other means,in order to maintain effective V p "-" - - -- ---- -" 1-ronmentai ence - Marrs mow Etherne, mo u e:.oc sc m round continuity to subsequent modules. Avg Panel Elnpellcy` 210:s_ _-2044e _ Outdnnr ree0 prucl's;everaUsystem re6adllry,and cu5fomerexperl PLC,W-H,and cellWar nveners,and hybnd BD[ 'I/M' �, g tY q •+ .p .. — .... Pat r6 Remotely stem report saes ''' Tenp,uel ipcwer, _ _ -O'OW,J`c Compaq footprint for lnproved aesMencs •'� ._ �, dAClsyscems ,�. .-<�•, w •rhmebyPasi tl�ode! creme Class l black arodued,r•gnest AAM 4,abng) Re[lµe ekcttJe system rlp,MS -' a _ Because themodules removre es paean ground chain"fas other downstream gone lee in the circuit. the circuit � Robust cloud Ennnedinty and comprehenslrt local cannealvhy =,� using the AC cable removes voltage and ground homtheother downstream modules in[baarcuit. o 5hatle 7ola•ancE •Integraletl rc✓,orll aW." mum pnvre ma'&'t_ _ 41 Ibs'n8fi rgl DiagnoLocate seracc me,and remoteydlaglose �'e i ".I' pvm nadl_t6- Nix Diagnose Issues Doane FNxlhle<orl9gwaoon of dev¢es durrngmstai:anon _ Extreme care should be taken to ensure that no other energized sources are adjacent to these --- -- ---' P.b.,nenced 1 3 it C3 mnl ungrounded modules,otherwise auxiliary grounding methods must be applied. 'anfpld Sparing Ural down for the status ofmdMdusl tlev,tes Conwmobon nlonaprng u de m a I n h -..-._.......____-_._._-.__...._.._-.._.-._.....____ R.al-grdde production—,forms P ecause a ewer s internal o e m u ,a grounding electrode conductor or e mcloule ourout ar::.UV(min!nom rma<3 211/2 101264 V Vveb-based comm-tar sg epic, or array is not required.The existing AC GEC at the utility service serves as the NEC-required GEC for the �(��apEE%/ Oufp,[:•2G8 V(min!nom/maul 1931206229V Remote diesnostus ofPV55x and-erters structure. ply Est. SIR Dpe Ili rreque r-y(n.m/nor nn_ex_____5.53/600160i Hz_ W„r•amms •2Syed'nateJ cower wdrra,ly tea;.:# cmga,nxe5u�nona A:umules su,w.w s6cdlu umulesrRsl ierlg,+raurc 3b^c rn,t'•cf 2=°cm•',4o°H W �as .° cart,... from he AC cable A. i our,,,rywwiarnrpninj 049 •25 yer'.mnetlu cduct wamamy .,F ^ ' - Durable lJEMA3Renclosure reduces malnrenance costs rn n4wr. Pa dP..Pvssv, Nw�wllytn..x•wri0 as+yn,mruuaviN Thend cable grounding path has been tested aNRTL,and its electrical continuity o S _ p by -------. -, _ _ ^ Cr,lPxiuoa,ulgtrwriers ronvsno,sMAnoyAeaua round into od le ftameh beenc fi AC 61ax CmunuoA 04[p,,t Cwrant @1240`/ ^33A •UL 1741,moud�ng Eompuarce veto 1 . >n eukxr;yrynudiwr P.Rsx) a poll abiereulements of IEEE'1S47aro1EEE ..Y q i� NgrsperneTerrndnra The AC module Interconnecting cable system provides an Internal EGC for grounding the AC modules.It E,p.os-st-1e 4C Max corun,,a4s Onpu C,nrantm203v 32bW 1,.a 1 - �mmwa<ras a.evw ruu.r arw+an F aG lea..Con[output vuwnr 320 w _ •AL module ryy 2 Fl,e Rated ,.�"'"""^,""'""";;"=^'=',"^:` ,As PLCfbr ndmeurs is the installer's responsibility to ground any metallic mounting structure according to local code. *r!'J� ((.Grit tCp \Q, -r rotor 2auvAcwerwle PLctprsaauAcrrfaun Installers must ensure that whichever mounting system they choose is then rounded according to the OVACit(G;nw:slon EfAcarcy, - -- 06004 •tit 1Jn3tis'a when,rs[allee wnh ngY ry g 8 -... .. --- _ .. ....... Cn•dume s).nr,y..r.1krrxn mnarhgJad9 Ma+inrsPer20ABrardlbcun1a240'✓ 11(singlenha.e) i1wslMo4rt'" meefedµrtmrlR ct2wcNaosle'dMocnlnnsulrMnaer.a iris[rucdonsofdrotmountingsystem.Somemoun[ingsystemscanbeho�dedtotheACpYmoduleswith �F CAL Cemticat am Claea A lire rated whin,Irsta led wIM1 Mar .,ion Prr 20 4 Branch nrnnt 9108 V 10(M+,P°le) Robust OU OMECCNI[y En,rrax wu.aw uv wu listed devices.Consult the nodule's included safety Instructions for details. Inws.,o t-and when detanre netvxen• f Add Value for Homeowners Multiple options to mamfamutimal suddce andbonomarsunPOwermodule p wade aWnsln°1 Plc ft,axW N,„„'r*edvv.,d..d+•'°^rw,^�u,""m xc rid the neutral conductor within the AC module is ii Wm1 the AmPpwer Monkoring sysem frdmels.3J CpnneC[Mly' Onx,vw!. M5rm a20ficmx9-3pn1Yi6mxA,nx3find rbM'n as OLvarY9 Opr anng-imp -r4)°'+c�t85°F(40°Lin by t'1 •Alitnot:,n&curnnt(AC)modultdes,graton homeowners can. eza.,I.Pave Ina, wf aD211oxm Ise a[ed rpm ground.The AC mo ueml3s[be mnnected[oadedlcated AC branch circuit with the enables mswxauon In accordance will,N'L Ndrtlaaretl Ethernet neutral conductor referenced at the building service entrance. • See thee wit system proauc¢seach Caxdw aourNrs' Ma.Ambler4 Temp 122'F150°q 6906 PMVer one Communication ryt() YJmtl SO p.t.24J0 Pa,2441,:,.1:�m6back tlay.mortth.or yxar zNa. ibm.aWmlw„mwnr rzmnuncrom,malrr•Mnp . The AC interconnecting cable system attached to each module'smlCroinverter is fully insulated and Mar-pap PIDT4s: Porar,el-nd.,:ed Deg•adauon free Opbm,ze their solar investment doll saw:on vi i 5uppa'B addlpordcmMNh3DX�9 up fo0.5AA'xa includes an Internal EGG The grounding pin is longer than the others in the plug. Snow 112 psi 5400 oa.550I,on, Nn+vc.rm websae IpppPOfJ6aOptle.L9m IAaTNwA enelyry expenses. Cellular backup Ib uempa cask,a,nmtMl Inca Iz5 mini tllameer not at 52 moo IY• Pdr•rx•I wel". soy"....m.•I�.,,.,,a.•n.,, The round path from the transition cable to the module frame is as follows: pea 5e°stance mrs) See tlWir energy,use and estimated bill savings z Ga lied• M.wwr, Pro.,S,la,Mom mli ie, Itsa PJM g -r- See their solar system's performance using rite µamClb*e I viAf0,mdAmmw° cam ask wrap wafts • The transition Cable's green Conductor is connected to the EGC from the utility dedicated branch s N I unPower monitoring weMhe or"talle app Ncmeuvna tin I nay+xw tnlae^o o^tln,n Up"""' aemaocM1mwnupaahs circuit,�u 2q,n mObb M.xe domJrGxR ra,nP'JVM Nmm�xrydP{' r r yE, ; 1 rrpmAndP cry sane«.Cana.nay am. • All plugs have ground pins that are longer than the circuit pins.This extra length ensures that the ,4 """' L a '"""'"r°pCp°ra p°�1010 round is the first to make contact when connecting modules and the last to break contact when s H 9i; _ r _-- wmarx° ,.,a ram w,na.y disconnecting modules. LU isa' U U --�._ - • EME,.Om NEEaxw950.ENb13241 a«.,•.,1 :,,. h "~ O U Supports Multiple Inverter Types The AC ground wire Inside the microim drier terminates on the microinverter chassis with a bolted U z supports SunPower 46 LOX module systems,DC strmg lnverw system; N connection,and isernironmental sealed. � N W V tit, fir erw .-are.x...r. nr°-..nwm,ltrvand°eoimonn.,yu.,arord..�: ardhybntl(DC.mdAC)systems [� OY Y W FCC The microinverter chassis is bonded to the module frame with stainless steel hardware to provide Ch J a r�'nW.`:«a, 'inwl•e11R.r ou3e°ii.v uminW"mn' aiae r�N ground continuity co the module frame. (n C7 g m Ln KC Iu YAW5134(12 ITE E477122 In ad Inn If amvw.warNw 1.4 o • e � Q ry p I¢� x J a U j In FIGURE A:PV MODULE SPECIFICATION SHEET FIGURE B:PVS5X DATA SHEET FIGURE C:PVS5X DATA SHEET FIGURE D:GROUNDING DESCRIPTION SHEET Q w o �q Switching Devices SafetYSwadses 1 1 o w e CERTIFICATE OF COMPLIANCE CERTIFICATE OF COMPLIANCE NOTICE OF COMPLETIONAND •OnMP lmndov ee;.ael-0vp.Pa.l6l.,slwda-Threw.conrs,uea Cortlncate Number 20150922-E479127 esrtfscato Number 20150918-E478330 AUTHORIZATION TO APPLY THE UL MARK 3 o""`"'a'a°P"rr'r'P° xEwl r■wa1 ReportRororence E479127-20150916 ReportRef-mi E478330-20150916 m U A F—try° H.1wmr•AO r.wn_r a E.....bl., Encbw.r oomal aw.m r.a. vrw,vo. I2w aes .1 env caalel■.ne.r cebim raves lesus Data 2015-SEPTEMBER-22 Issue Date 2015-SEPTEMBER-18 08I19l m ,zp(ra,igR,atrip.-TInwP1k,Txa.kw.Irhr.eadll,Thr.Fnr4-2ae v.,, Sunppwer Corp at Kevin Flochal, Issued to: SUNPOWER CORP w 7 T}}" ® o e Issued to: SUNPOWER CORP 1414 mour ways tinrnrr a asRichmondCa g4gW-38B4,United Sfalac o as, - - - - ® m 77 RIO ROBLES 77 RIO ROBLES r' ex R eF 11121 - sa RNeas D6-FRAem SAN JOSE CA 95134-1859 SAN JOSE CA 95134-1859 r*'%'rea9ifyl,. ' 47ese7s345 mR Olnardil• IXa%IRNdm Our Reference: Reference: Your Rotorenw: 1 ',•'t..1: 0Wd9,7VP.-Fuun%rm mini.0.4...Thr.N..,elm-120/210wd ., ' d b A m - bU2a a-nrz - oraoca DmaNle This is to comfy that COMPONENT-STATIC INVERTERS AND CONVERTERS This is to certify that AC MODULES r' ,r (,•"'; U) f p d M m x _ 3-,. 1.In-1s = subboRR Rm®ie representative samples of FOR USE IN INDEPENDENT representative samples of USL-AC modules,Models SPR-X21-335-BLK-C-AC,SPR- Pro)etx scope - ;, t'' w mombr arm,Model Pvs5x piaoadamdlitifJ"•;,v)sn, rr9�a Z- Z Y4 Y4 mo x 2,rz-1s ,tee saaod" Ilmane X20-327-BLKL-AG SPR-X21-345-C-AC,SPR-l(21-335-C- r ' 2Rt x - 1s ssm - a-ar DmRrm "See Addendum page" Deer ICov :, ,�r.t,.. :'Y+''=. U 4w 11 - - 5.125 - a:aaaex D-slap AC,SPR-X20-327C-AC.SPR-E20-327-C-AC,SPR-E19- Congra `i complot undertheelawaR and i--i aaaMOR IM.IaMR 320-C-AC thep Inge the ueaments.This I~lempbour UL U) Have been investigated by UL In accordance With the Fall Procedu ee apply the UL Mark st authodzee Standard(s)indicated on this Certificate. USL-(QHZS),Evaluated to the requirements of the Fall Progrem r s)won the blamed prized undotion ro use > owaaea 120/290 Vac Q.,..N-0ate NomFraysbl.,Sind•-Tteow copy of thiB men rrently eulhor2etl antler Fila E4 1. Y.L n-Fispewe,Singl Standard for Safety for Inverters,Converters,Controllers " - u.I 11FaN31 aENAaR Fork, Up being Prepared and will a AmP„ er.I•m...Ac u_mn.M at ea—niax. E.I-rea.l...l standard(:)for safety: UL 1741-The Standard for Sate for Inverters,Converters, end Interconnection System Equipment for Use With 9pnm Rmry ISM Y90Y eRly few emlq NrrMr Cerel°re•.k.r U1Na tllan lhle -a 80 tlByB horn the dale lndkW - - Controllers and Interconnection System Equipment for Use Distributed Energy Resources,UL 1741,Second Edition, c »; A TM"P°I dated January 28,2010. ulrenlenla re,a Da round b Me document• { z a 3 o-,faces ooemato With Distributed Energy Resources. ry related to Ions ng webelre: + 'Ark•! of re _ _ IEEE 1547-The Standard for Interconnecting Distributed 1s - - Drar.F,cem arnfaADm Resources with Electric Power Systems. Have been investigated by UL in accordance with the and dowmen ad to u rg 111.11 pfil'loes are provided on behalf u CAN/CSA 22.2 No.107.1-1,"General Use Power Supplies" «anorizeeRcen {, ,-� Tlw.4.ah,ihr.xrl..phi.aba.el-a.v a Standard(s)indicated on this Certificate. liI, , l.I UL 1703-Standard for Safety for Flat-Plate Photovoltaic b rj b 5 a T4r2 - caboarv— R-,cram Modules and Panels. any WourCwtemer yes qq your bualrwa P Rstaa3De® DcmuRem Inverters, , 4 P 4 I. - 1, so - aaa,oao amumo Additional Information: �the UL Online Certifications Directory at standard(s)for safety: UL 1741 Standard forSafetyfor o rtars, V r t,;AN ••if PC 2m 15 m - _.. asbestos. www.ul.com/database for additional Information Controllers and Interconnection System Equipment for Use ,yj ' i, A �;., I 4. - - 15 - Ixaas,cxs Dc�i,Asm With Distributed EnergyResources. 1� Re ,f,� sin - - 2m - p-wcxs Isl�urrm r rot •'S'; OPPORTUNITY 007942 Additions]Information: See the UL Online Certifications Directory at 2""'*�• '- �� ,''I''^i.,J;•%'! ^w•d Kst■A, Only those products bearing the UL Certification Mark should be considered as being covered by UL's www.ul.eom/database for additional information s"",;` Brulpl` •i:,;.x�/'7..N ' mek.mmlewin+ww mb.brewi 4.r.a,l,r.adnlua.r.m.a calcification ation and Follow-Up Service. senior I 84T-BB43009 v"!' �jy ,i s m.mumnaraa2 mrm.r.teak. s ' CPO DIrBcter •9' PROJECT D-0053493 a 5.id-marr.we,a l.R&1 firer eepastdrlromle9eonPop W-n.Is KareA +• 811EWAMehanhpe®1a. 1 s YNA•INa swim n.l sam". 011.1 Recognized components are IncompNte In certain constructional features or matrlaed In pedomrance +,2�• ®mebr.wrcuadVdIaI aml capabaRles and am Intended for use as components of complete equipment submitted far Investigation rather Only thoseandFproducts bearing the ce certification Mark should tea considered as being covered by UL's of,•;.t�f" �„•1.•e a Duim,oaaA,i eeielma.d.Umwa then for direct separate installation In the field.The final acceptance of the component is dependant upon its certification end Follow-Up Sallee. .;i "r. ., 1 yr"�"' 9�'!"4'• DATE DRAWN 06-14-2016 anR..aamsuey.arlw ea�wne�nlnr«btea s,•'sA n,A�J• y wv '3°,.rr„ ^rsrc^7h:..xt.t,�"al n installation era use In complete equipment submitted to UL I.A.C. eps• m=meaelei0ann"i° cdei�nl,a�T�"msfisDP•n�a1`me8se'smlAllpB""p18d°eln.dMMa«alebaein«aril, Look bar fieULCertificationMad[ontheroducl. NBKFCDAI8a67 f , Look for the UL Certification Mark on the product. .:yI,, d4.,;+„ .'+}jj=,�d {f/•' DRAWN BY MMENDOZA DATE CHECKED 06-14-2016 CHECKED BY EE-GBFS �p.awaa ,.cwu.r•v.+w•+�rr,,.•..w...r...w. •,w��., ucwu..w,w.,r l..,..ar.ww.•.•.r.. VeLm.2-Cammra•IdmlRlmtl.n CA0Vtx01E-rlP,,•Y2013 wrw,«en can tit-Tf-27 Pag"t°12 P.PI of, Mbban.ma,mic.lymmmmnPaia,Rlarwhmor an nPf,eq.I.J ter e,b-rim b tea v.M. a.p.10 NOT TO SCALE SHEET SOLAR-E3 FIGURE E:AC DISCONNECT DATA SHEET FIGURE F:MICRO INVERTERS COMPLIANCE LETTER FIGURE G:AC MODULES COMPLIANCE LETTER FIGURE H:UL LISTING of g tpg W m O FYK frig m a a c m a � Yg5 .e !$ [f�) _ o W H! a II 131 IS° �Bfig q Pa5ba1 a v E =y 3 §� r-I O O z N N D� CY € E 6'3 $ $L a. LW d g 4 Y 4 Z a a a u 183 s. ) 2 r e P zt ; J I I � � m ail ' r I i Ifj#� I' i' fW �r li E � gg !! �� �pFESS� � .�P $ li �i� r1 (��1 � SI x$ y y i 4 " A �D� f Of CAl lit, €�+a, z p -g 'a t �i .z! a@ $° Eye Ga w U U i1a A xstra' � € e! ga III p!r 0a QLL I•os I �s" g Z U CJ p g g r p I! F € " s 3 �� o 'rLU ��� �Y� � M g m � �Fp "€ 5q 7k�, dLE I— 3k N dS x ® 111 gP a6� @€gg S s ° g as Q 6 g ..... .. V) Q' Q o U � K FIGURE A:PV85X QSG FIGURE B:PVS5X QSG Q �u LU w a� w Continental Control Systems y m w rc s _ f � eu7 CME ant transformers make imtellation r because they can be i'miled without ~' $d� rsy^<� }"''+• �" k4.i '�• d—on-1mg the.—It being measured Spll-mro went ttansformera ale available In a range of stack rfz, mm sizes and rated currents to meet your measurement # V Model Model Model CTS-0750qxxx) CTS-1250J—) CTS-200"—) 0.76"1 D 1.25"I.D. 2 00•I.D. Rated Model Rated Model Rated 0 SuffixAmps nor fin na A SLdfix na 15 •015 800 -800 k. •.�,�� k 30 -030 600 -800 50 .050 200 -200 1000 -1000 .070 250 -2 179 -200 Z 100 -100 300 -300 -1500 1 =150 400 400 200 -200 600 -800 U) A 4E W ^�/ ���IIVJJ � CC ` D B III h 0e333' AC OUPpu j 0 Size CTS-075D I CTS-1250 CTS-2D00 A 5.08 cm 845 cm 72.1 era B m. 3 m. 5 00 n 533 cm 851 cm 12.7cm pre OPPORTUNITY 007942 O 0.61 in 1.00 in. 1.20 in. 1.55 cm 2.54 cm 3.05 cm O 0. in. 1.2 n. 2,00 in. PROJECT D-0053493 1 91 cm 3.18 cm 5.08 cm „r, g.„,,,,y, E 0.7 Ie. m. m as fj,R,rr'{{r 1.91 cm 318 ctn 5.08 ctn ion DATE DRAWN 06-14-2016 p®w a+� �e •No m�oaed metal pent on •UL a CE recoanlxed for voltages evembled oanefolmar up to 600VAC. DRAWN BY MMENDOZA (888)928-8663 IMemelpmaawnwidenmeet. .0.333vAC.Wutarratedarrant same aamnda y •Aaumw.l%from 10%10 130% •Epoxy anmpeulatetl houslrq. of rated anent.. DATE CHECKED 06-14-2016 Conlnental Central Syseemle LLC •Leads-ae.twisted pail,22 AWG. •Phase angle<2 degm-fx 3131 Indan Road,Sulfa A C73-0750 model$>71 Amm& Boulder,CO 80301 USA •Co. erle—d at Joint$for CTe-1250 modal$>'150Amm. (888)928-8663 Fax(303)444.2903 accuracy •snap closMWmxring restore. CHECKED BY EE-GBFS IM saies@cctxltrolsys.com •Phaaeeegle l$me—del 50%er NOT TO SCALE www.wattnode.com reled current. •RoHB Compnanl SHEET SOLAR-E4 FIGURE C:CURRENT TRANSFORMER SPECIFICATION SHEET