Loading...
HomeMy WebLinkAbout06-017 lMATCH LINE-STA 7+W I COLLIER / STA 7+00 0 r (SR74) AVENUE --------------- -------------------- - _ �" Till -------------------------------- ------------------------------------------------ EXISTING TR FFlC Z SIGNAL (SE SHT. E-1) 43+00 44+00 45+00 46+00 47+00 - i -48+0+0 _ _ 49+00 - _ 50+00_ 51+00 - W 2-C,2#8,1#8 GRD 2-C,2#8,1#8 GRD 2'C,2#8,1#8 GRD I I 0 + m o I ' I N � n -- v 3 2'C,4#8,1#8 GRD I �� ( I + I + f 3 + 0 ; � I 3 ( I ) SERVICE POINT I 2 v-i I STA 5+00 0 N SCE TRANSFORMER PAD � U rJ I W I I I 0 W. i N Z I. I / I < ' I 8' I 2-C,2#8,1#8 GRD I j CONSTRUCTION NOTES(THIS SHEIFO' I I RAINCAP — 2"C,2#8,1#8 GRD I O7 - INSTALL 120/2�OI TYPE III-BF SERVICE EQUIPMENT ENCLOSURE I o 22,000 LUMEN LUMINAIRE(20OW) WITH TYPE V PEC.CONTACTOR(DP),TEST SNITCH AND 2-40 0 FULL CUT-OFF AMP(2-POLE)LIGHTING BREAKERS. LIGHTING CIRCUITS.SHALL 3 HIGH PRESSURE SODIUM TYPE � BE 240V METERED. STA 10+80 l.�.l INSTALL 3'PVC SCH.40 CONDUIT KITH PULL ROPE PER UTILITY COMPANY REQUIREMENTS. I ' I AT LEAST 48 HOURS ADVANCE NOTICE SHALL BE GIVEN TO SOUTHERN CALIFORNIA EDISON I I I COMPANY BY CONTACTING LINDA MARTINEZ AT(951)566-6494. EXACT LOCATION OF - CONDUIT SHALL BE DETERMINED BY SCE IN THE FIELD. fill 3 IWDESIGN PARAMETERS INSTALL ORNAMENTAL CONCRETE ELECTROl1ER W17H 2O0W HPS U '-80 MPH WIND FACTORLUMINAIRE(24M PER COUNTY OF RIVERSIDE STANDARD NO.1001.(SEE DETAIL). ZSTA 3+00 o-1.3 GUST FACTOR + n ROUND OR OCTAGONAL. TAPERED POLE i (. , r W n N ACRYLIC ANTI-GRAFFITI COATING. W O U I + Z ; 2-C,2#8,1#8 GRD W I I. I i 2-C,2#8,1#8 GRD I I I ' I I Ii 0 I 4.5_= ' I N .rr STA 8+95 , m 4-1'x36'x4' ANCHOR BOLTS L I I I 4a SQUARE OR ROUND FOUNDATION Z I I W I I STA 1+00 + ORNAMENTAL CONCRETE LIGHTING STANDARD DETAIL U I ' 3 NO SCALE I o I m 2-C,2#8,1#8 GRD PASADENA '.; E-3 MATCH LINE-STA 7+50 AGA Job No. 652-003 o AGA File Name: TARSTREETLIGHT.DWG o Print Date 12/12/05 o+ Last Revision 12/12/05 THIS PLAN ACCURATE FOR ELECTRICAL WORK ONLY CALTRANS PERMIT NO.08-05-6-MC-0482 THESE PLANS HAVE BEEN RENEWED FOR.COMPLIANCE IWTH THE APPROPRIATE PREPARED BY: (714)992-2990 rk MARK REVISIONS APPR. DATE CONDITIONS OF DEVELOPMENT AND/OR CITY AND STATE LAWS AND HAVE BEEN � FAX 992 288T C LIGHTING PLAN C W OF LAKE i3 SHEET \ FOUND ACCEPTABLE 1_ 1LBERT `g "P�% m nwDta<tcal./ro of twee nNo c-u�T c.Re Rrrr/tw A/6Mf-OF-WAY — GROVER & 4 Re(oeAno.� err enw,e eLaI�Melvr—sEe /a a �C�,� � o> /�oe ASSOCI.A►TES ,-,aa, SCALE: o AVENUE(8A7� y� i B 13 BENCH MARK: STA COLLIER TO A�E OF SHEETS p DATE �,, clvl� 1"=40' oCENIAALA1/BdiJE KEN A.SEUMALO,RCE.No.56915 TRANSPORTATION CONSULTING ENGINEERS FILE No. CITY ENGINEER 12 12 05 COLLIER AVE TO PA8{1DHVA BTFI�� �I CITY OF LAKE ELSINORE 211 E.Imperial Hwy.,Suite 208 Fullerton,CA 92835 DATE: 1J�0'�I� 4ffrew4 Z 14y :��. o,6 /411.17!Aft�ei a�e•S