Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
OBARIA WAY 36548_15-00002499
CITY OF LADE / LS11101,E BUILDING & SAFETY DREAM E,�TREME TM 130 South Main Street Lake Elsinore Ca. 92530 PERMIT PERMIT NO: 15-UUUU�Z4-919 DATE: -9/10/15 JOB ADDRESS . . 36548 OBARIA WAY LT76 DESCRIPTION OF WORK ELECTRICAL OWNER CONTRACTOR PARDEE SOLARCITY CORP. 3-0 5 5- C-LEAK-V-3 EW--WA-Y--_._�__-- ------,- ---. LAKE ELSINORE CA 92532 SAN MATEO, CA 94402 650-638-1028 LIC EXP 0/00/00 A. P.# . . . . . 358-372-005 9 SQUARE FOOTAGE 0 OCCUPANCY . . . . GARAGE SQ FT 0 CONSTRUCTION FIRE SPRNKLR . VALUATION . . . 15, 000 ZONE . . . . . . R=1 BUILDING PEMIT QTY UNIT CHG ITEM CHARGE BASE FEE 63.. 00 13 . 00 X 12 . 5000 VALUATION 162 . 50 ELECTRICAL PE IT QTY UNIT CHG ITEM CHARGE BASE FEE 30 . 00 1 . 00 X 16 . 2500 MISC. WHERE NO OTHER FEE 16 . 25 FEE SUMMARY CHARGES PAID DUE PERMIT FEES BUILDING PERMIT 225 . 50 . 00 225 . 50 ELECTRICAL PERMIT 46 . 25 . 00 46 . 25 OTHER FEES PROF.DEV. FEE 2 TRADES 10 . 00 . 00 10 . 00 PLANNING REVIEW FEE 45 . 10 45 . 10 . 00 PLAN RETENTION FEE 2 . 07 . 00 2 . 07 SEISMIC GROUP R 1. 95 . 00 1 . 95 PLAN CHECK FEES 169 . 13 169 . 13 . 00 TOTAL 500 . 00 214 . 23 285 . 77 SPECIAL NOTES & CONDITIONS ROOF MOUNTED SOLAR WITH 20 PANELS, 1 INVERTER 5 . 2 KW - Z r City Of Lake Elsinore Please read and initial Building Safety Division wi—I am Licensed under the provisions of Business and professional Code Section 7000 et seq.and my license is in full force. Post in conspicuous place 2.I,as owner of the property,or my employees w/wages as their sole compensation will do the work on the job and the structure is not intended or offered for sale. 3.I,as owner of the property,am exclusively contracting with licensed contractors to construct the You must furnish PERMIT NUMBER and the project. JOB ADDRESS for each respective inspection: 4.I have a certificate of consent to self nsure or a certificate of Workers Compensation Insurance Approved plans must be on job or a certified copy thereof at all times: 5.1 shall not employ any person in any manner so as to become subject to Workers Compensation Laws in the performance of the work for which this permit is issued. Note:If you should become subject to Workers Compensation after making this certification, Code Approvals Date Inspector you must forthwith comply with such provisions or this permit shall be deemed revoked. EL01 Temporary Electric Service PLO1 Soil Pipe Underground EL02 Electric Conduit Underground BP01 Footings BP02 Steel Reinforcement BP03 Grout BP04 Slab Grade PLO 1 Underground Water Pipe SSO1 IRough Septic System SWO1 On Site Sewer BP05 Floor Joists BP06 Floor Sheathing BP07 Roof Framing BP08 Roof Sheathing BP09 Shear Wall&Pre-Lath PL03 Rough Plumbing EL03 Rough Electric Conduit EL04 Rough Electric Wiring EL05 Rough Electric/ T-Bar MEO 1 Rough Mechanical ME02 Ducts,Ventilating PL04 Rough Gas Pipe/Test PL02 Roof Drains BP 10 lFraming&Flashing BP 12 Insulation BP13 Drywall Nailing BPI I Lathing&Siding PL99 *Final Plumbing EL99 *Final Electrical NM99 *Final Mechanical BP99 *Final Building 'Final Signatures are Certificate of Occupancy for Single Family Residence Code Pool&Spa Approvals Date Inspector. OTHER DIVISION RELEASES SPO i Electric Conduit UG Department Approval required prior to the SP02 UG Gas Piping ' building being released by the City SP03 Tool Steel Rein./Forms Date Inspector SP04 Pool Plmb./Pressure Test Fire SP05 Pre-Gunite Approval EVMWD SP06 Rough Pool Electric Finance SP07 Pool Fence/Gates/Alarms Engineering SP08 Pre-Plaster Approval TUMF - SP99 Final Pool/Spa Planning/Landscape r ! • CITY OF l/^� LAKE ULS1ri0P.,,E DREAM EXT RE M E T. 130 South Main Street APPLICATION FOR APPI) � °-N . BUILDING PERMIT APPLIC N CEI�(F�D— DAT '`r �J VALUATION CALCULATIONS BUILDING ADDRESS lit FLOOR SF TRACT BLOCK/ AGE LOT/PA#ytL 2nd FLOOR SF NAME 3rd FLOOR SF O W MAILING Same PHONE GARAGE SF N ADDRESS E CITY Lake Elsinore STATE/ZIP STORAGE SF R I hereby affirm that I am licensed under provisions of chapter 9(commencing DECK&BALCONIES SF with section 7000)of division 3 of the business and professions code,and C my license is in full force and effect. OTHER: SF O LICENSE# CITY BUSINESS N AND CLASS 888104/bc10c46-Ax# T NAME VALUATION: 15, 0 0 0 R Solarcit A MAILING C ADDRESS 3055 Clearview Way FEES C T CITY STATE/ZIP PHONE O BUILDING PERMIT 3 R CONTRACTOR'S SIGNATURE DAi E PLAN CHECK NAME LICENSE# A PLAN REVIEW R MAILING C ADDRESS SEISMIC H CITY STATE/ZIP PHONE PLAN RETENTION ❑NEW OCC GRP./ CONST. ❑ADDITION DIVISION: TYPE: ❑ALTERATION NUMBER OF NUMBER OF ❑OTHER STORIES: BEDROOMS: ❑SINGLE FAMILY ZONE: ❑APARTMENTS ❑1 certify that I have read this application and state that the ❑CONDOMINIUMSS HAZARD. YES Z : above information is correct.I agree to comply with all city []TOWN HOMES AREA-1z and countyordinances and state laws relatingto building �COMMERCIAL SPRIN I�S,.= �•- ' " Y ' r- II m m r' I .. ;a� 1 construction,and hereby authorize representatives of this ❑ .G INDUSTRIAL REQUADO x m i - m NS�••A 1 - II city to enter upon the above-mentioned property for insp- [I REPAIR PROPOSED USE OF BLGev. = i II s• T i i , r,"1-.— tion purpose ❑DEMOLISH PRESENT 'SE OF B'DQ,. '-' r' a';' 11 � '_' _°- c. T JOB DESCRIPTION .10 r�i .� _.a �. 11 a _j rm- residential roof mou t �� -1 11 C„ Signature of Applicant or Agent Date r:a F II - , . to r: II m panels 44 � Agent for [2kcontractor ❑ owner (A r•. II I. n. , Agents Name Beverly Miller 11 Agents Address Murrieta, CA 92562 '- µ � _ 0 0 , p +` t Version#49.2 ���®�SolarCit WS SSION4Z August 31, 2015 Pc2��kAGHgL,y2 Project/Job#9258142 RE: COVER LETTER G1 J Project: Rowe Residence 36548 Obaria Way Lake Elsinore,CA 92532 To Whom It May Concern, s�gTE OF Structural review was based on Truss Calcs and the design criteria listed below: g 1^ti'111'S Design Criteria: -Applicable Codes= 2013 CBC,ASCE 7-10, and 2012 NDS - Risk Category = II -Wind Speed = 110 mph, Exposure Category C -Ground/Roof Snow Load = 0 psf - MP1: Roof DL= 14 psf, Roof LL= 20 psf On the above referenced project,the components of the structural roof framing impacted by the installation of the PV assembly have been reviewed. After this review it has been determined that the existing structure is adequate to withstand the applicable roof dead load, PV assembly load,and live/snow loads indicated in the design criteria above. The structural roof framing and the new attachments that directly support the gravity loading and wind uplift loading from PV modules have been reviewed and determined to meet or exceed structural strength requirements of the 2013 CBC. Please contact me with any questions or concerns regarding this project. Sincerely, Sri Raghavan, P.E. Professional Engineer T: 888.765.2489 x55470 email: sraghavan@solarcity.com 3055 Clearview Way San Mateo,CA 94402 T(650)638-1028 (888)SOL-CITY F(650)638-1029 solarcity.com .li ROC 243771.CA CSt_E3©oIIln•„CU cC c 0 41,CI HIIC 0032772 DC HIC 711U14b6.DC HIS 71101A83,FII CT 20770,1,M HIC IC85T 2.MD hIH IC 12E30-18.NU 1WHOCI0000O• UR CC13 18'4'13,PA 0773.13,TK TOLR 2�OOh1`7JA GCL.SOLARC'01"LD7. '013 lights re:co•.,tl. 08.31.2015 PV System Structural Version #49.2 I SolarC�t� Y Design Software PROJECT INFORMATION &TABLE OF CONTENTS Project Name:iRowe Residence AHJ: Lake Elsinore Job Number:1 9258142 Building Code: 2013 CBC Customer Name: Rowe,Amy Based On: IRC 2012/ IBC 2012 Address: 36548 Obaria Way ASCE Code: ASCE 7-10 City/State: Lake Elsinore, CA Risk Category: II Zip Code 92532 Upgrades Req'd? No Latitude/ Longitude: 33.661590 -117.277960 Stamp Req'd? Yes SC Office: Murrieta PV Designer: Wubing Ye Calculations: Sri Ra havan, P.E. EOR: Sri Ra havan P.E. Cover Letter 1 Project Information, Table Of Contents, &Vicinity Map 2 Seismic Considerations 3 Structure Analysis (Loading Summary and Member Check) 4 Hardware Design (PV System Assembly) 5 1 2-MILE VICINITY MAP j.. 141 '• ' ''_ •� 1� � �♦ W �III A� 1I d a s � t L -a ~ . 'w ' .i ! r1 ri 36548 Obaria Way, Lake Elsinore, CA 92532 Latitude: 33.66159, Longitude: -117.27796, Exposure Category: C r SEISMIC.CONSIDERATIONS Seismic sign Criteria (per USGS Seismic Design Code ASCE 7-10 Latitude 33.6616 Longitude -117.2780 SRA at Short Period Ss 1.558 USGS SRA at is Period Sl 0.600 USGS Soil Site Class D IBC 1613.5.2 Seismic Design Category SDC D USGS Seismic Check Required(Ss'>_',, o: &.SDC>_ D)?. . . Yes IBC 1613 1 ALTERATION.LATERAL.DESIGN IO o.-EXCERTION:CHECK ' Weight of Proposed PV System Area 'Dead Load Weight PV System Weight 354 sf 3 sf 1063 Ibs Total Weight of PV System -T-W—cp ) 1,063 Ibs Weight of Roof on Existing,Building Sum Area of MPs with PV 400 sf . Portion of Roof Weight Area Dead Load Weight Roof 400 sf 14.0 psf 5,600 Ibs Ceiling 400 sf 5.0 psf 2,000 Ibs Interior Walls(Top Half) 320 sf 5.0 psf 1,600 Ibs Exterior Walls(Top Ha 320 sf 8.5 psf 2,720 Ibs Net Weight of Roof Under PV W(exist) 11,920 Ibs Check%Increase of Roof Weight/.Seismic Shear Load Increase of DCR of Lateral 8.9%` Force•Resistin S stem N►crv�/W�e715`� Increase Seismic Shear Load< 10%;.-->'[OK] IBC Sect.3404.4 Note: Seismic base shear is directly proportional to roof weight. :STRUCTURE ANALYSIS =-LOADING SUMMARY AND MEMBER,CHECK-'MP1 _ Member Properties Summary MP1 : Horizontal Member Spans Rafter Properties Overhang 1.24 ft Actual W 1.50" Roof System Properties San 1 6.53 ft Actual D 3.50" Number of Spans w/o Overhang) 3 San 2 3.51 ft Nominal Yes Roofing Material Flat Tile Roof San 3 7.00 ft A 5.25 1n.^2 Re-Roof No Span 4 S. 3.06 in.A3 Plywood Sheathing Yes San 5 I 5.36 in.A4 Board Sheathing None Total Rake Span 19.22 ft TL Defl'n Limit 120 Vaulted Ceiling No PV 1 Start 1.42 ft Wood Species DF Ceiling Finish 1/2"Gypsum Board PV 1 End 14.67 ft Wood Grade #2 Rafter Sloe 180 PV 2 Start Fb 900 psi Rafter Spacing 24"O.C. PV 2 End F„ 180 psi Top Lat Bracing Full PV 3 Start E 1600000 psi Bot Lat Bracing At Supports PV 3 End Emit 580000 psi Member Loading Summary Roof Pitch 4/12 Initial Pitch Adjust Non-PV Areas PV Areas Roof Dead Load DL 14.0 psf x 1.05 14.7 psf 14.7 psf PV bead Load -PV-DL 9.0 psf x 1.05 9.5 psf Roof Live Load RLL 20.0 psf x 1.00 20.0 psf 20.0 psf Live/Snow Load LL SL1,2 Total`Load Governin •LC 'TL.. 1 34'1 psf 44.2 �sf. Notes: 1. ps=Cs*pf;Cs-roof,Cs-pv per ASCE 7[Figure 7-21 2, pf=0.7(CJ(Ct)(IS)pg; Ce=0.9,Ct=1.1,IS=1.0 Member Design Summary(per NDS) Governing Load Comb CD CL '+ CL CF Cr ., .D.+-Lr ;.. 1.25, 1.00: :_0.92 1.5 . 1.15- Member Analysis Results_ Summary Maximum Max Demand @ Location Capacity DCR Load-Combo Shear Stress 84 psi 1.2 ft. 225 psi 0.37 D + Lr Bending + Stress 1260 psi 14.7 ft. 1941 psi 0.65 D+ Lr Bending - Stress -1259 psi 11.0 ft. -1793 psi 0.70 D+ Lr Total Load Deflection 0.32 in. 272 14.5 ft. 0.74 in. 120 0.44 D+ Lr a CALCULATION OF-DESIGN WIND LOADS -'-MPI- Mounting Plane Information Roofing Material Flat Tile Roof PV System Type SolarCity SleekMountTm Spanning Vents No Standoff Attachment Hardware SM Tile Roof Slope, 180 Rafter Spacing 24"O.C. Framing Type/ Direction Y-Y Rafters Purlin Spacing X-X Purlins Only NA Tile Reveal Tile Roofs Only 13" Tile Attachment System Tile Roofs Only SM Tile ,Standing Seam/Trap Seam/Trap Spacing SM Seam Only NA Wind Design Criteria Wind Design Code ASCE 7-10 Wind Design Method Partially/Fully Enclosed Method Basic Wind Speed V 110 moh Fig. 26.5-1A Exposure Category C Section 26.7 Roof Style Gable Roof Fig.30.4-2A/B/C-5A/B Mean Roof Height I h 1 25 ft Section 26.2 Wind Pressure Calculation Coefficients . Wind Pressure Exposure KZ 0.95. Table 30.3-1 Topographic Factor KA 1.00 Section 26.8 Wind Directionality Factor Kd 0.85 Section 26.6-1 Importance Factor I NA Velocity Pressure qh qh = 0.00256(Kz)(Kzt)(Kd)(V^2)24.9sf Equation 30.3-1 Wind Pressure Ext. Pressure Coefficient U GC „ -0.88 Fig.30.4-2A/B/C-5A/B Ext. Pressure Coefficient Down GC Down 0.45 Fig.30.4-2A/B/C-5A/B Design Wind Pressure p p= qh(GC) Equation 30.4-1 Wind PressureU " : -21.-8 psf - Wind.Pressure Down. = 16.'0 psf. ALLOWABLE STANDOFF'SPACINGS X-Direction Y-Direction Max Allowable Standoff Spacing Landscape 72" 39" Max Allowable Cantilever Landscape 24" NA Standoff Configuration Landscape Not-Staggered Max Standoff Tributary Area Trib 19 sf PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff T-actual -221 Ibs Uplift Capacity of Standoff T-allow 446 Ibs Standoff Demand/Capacity DCR 1 49.6% X-Direction Y-Direction Max Allowable Standoff Spacing Portrait 48" 65" Max Allowable Cantilever Portrait 19" NA Standoff Configuration Portrait Not-Staggered Max Standoff Tributary Area Trib 22 sf PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff T-actual -248 Ibs Uplift Capacity of Standoff T-allow 446 Ibs Standoff Demand/Capacity DCR 55.5% ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID-INTERTIED VIA A ALL EXPOSED CONDUIT WILL BE PAINTED TO AC ALTERNATING CURRENT UL-LISTED POWER-CONDITIONING INVERTER. MATCH HOUSE. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. CONC CONCRETE 3. A NATIONALLY-RECOGNIZED TESTING ALL LABELS WILL BE MADE FROM REFLECTIVE DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN MATERIAL. EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING SMOKE AND CARBON MONOXIDE DETECTORS TO BE EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, INSTALLED PER CRC R314 AND R315. FSB FIRE SET-BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED HAZARDS PER ART. 690.17. A LADDER SHALL BE SET UP AND READY FOR THE CITY 0 F LAKE E LS I N 0 RE GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE INSPECTION. GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY .HDG BUILDING DIVISION HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(8). Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR a Ejss inorO kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC city of Lak r . 1 LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). jn HIV«��� p �SI '`� i+t /Z� MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN Pla��e (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY _-- NEUT NEUTRAL UL LISTING. Approved 13Y"'Oii�i NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL-LISTED LOCATION PROVIDED BY THE ` APPROVED PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING oate "--q— POI POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT •' 3R NEMA 3R, RAINTIGHT - PV1 COVER SHEET PV2 SITE PLAN 1 - — PV3 STRUCTURAL VIEWS _._�.. PV4 UPLIFT CALCULATIONS f • PV5 THREE LINE DIAGRAM LICENSE GENERAL NOTES "` f ° °" it . � R� .r � =` _ �� }� � � Cutsheets Attached 1. ALL WORK TO BE DONE TO THE 2013 CA # 888104 CALIFORNIA BUILDING CODE AND THE 2013 — C-10 CALIFORNIA RESIDENTIAL CODE. Ben Liu 2. ALL ELECTRICAL WORK SHALL COMPLY WITH �. THE 2011 NATIONAL ELECTRIC CODE AS AMENDED BY THE 2013 CALIFORNIA ELECTRIC CODE. MODULE GROUNDING METHOD: ZEP SOLAR AHJ: Lake Elsinore L •- REV BY DATE COMMENTS }_. . ---- - -- ill REV NAME DATE COMMENTS UTILITY: Southern California Edison CONFIDENTIAL — THE INFORMATION HEREIN M NUMBER: J B-9258142 00 PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BEE USED FOR THE ROWS, AMY MEADOW RIDGE - LOT 76 Wubing Ye SolarCity BENEFlT OF ANYONE EXCEPT SOLARCITY INC., NOUNTING SYSTEM: �•.,,: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP ZS Tile FTile 36548 OBARIA WAY 5.2 KW PV ARRAY ►r PART TO OTHERS OUTSIDE THE RECIPIENTS MooutEs LAKE ELSINORE CA 92532 ORGANIZATION, EXCEPT IN CONNECTION WITH , 3055 Clearview Way THE SALE AND USE OF THE RESPECTIVE (20) KYOCERA # KU2606XPA PAGE NAME: SHEET: REV. DALE Son Mateo, CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T:(650)Son Mae CA 94)638-1029 PERMISSION OF soLARgTY INC. ABB PVI-4.2-OUTD-S-US-Z-A 9512191556 COVER SHEET PV 1 8/30/2015 (888)—SOL—CITY(765-2489)www.sdarcity.aam E}an Liu PITCH: 18 ARRAY PITCH:18 MP1 AZIMUTH: 190 ARRAY AZIMUTH: 190 MATERIAL: Flat Cement Tile STORY: 2 Stories STAMPED & SIGNED FOR STRUCTURAL ONLY 3' FSB S\ONAL E -- GHA�q %FF -- = // �� � c,� Q LEGEND co _ M 1 6'cs _ _ �d G\J�v ���� 0 (E) UTILITY METER & WARNING LABEL / M Sj F GQy INVERTER W/ INTEGRATED DC DISCO ATE 0 -y�� "� & WARNING LABELS © DC DISCONNECT & WARNING LABELS A AC DISCONNECT & WARNING LABELS DC JUNCTION/COMBINER BOX & LABELS DISTRIBUTION PANEL & LABELS AC LC LOAD CENTER & WARNING LABELS 0 DEDICATED PV SYSTEM METER STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR --- CONDUIT RUN ON INTERIOR GATE/FENCE O HEAT PRODUCING VENTS ARE RED (E) DRIVEWAY Front Of House L J INTERIOR EQUIPMENT IS DASHED N TOTAL ARRAY AREA (SF): 362 SITE PLAN 36548 Obaria Way TOTAL ROOF AREA (SF): 2535 Scale:1/16" = 1' E _ w TOTAL ARRAY AREA IS a 14 01' 16' 32' PERCENT OF TOTAL ROOF AREA Aims CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER: J B-9 2 5 814 2 00 PREMISE OWNER: DESCRIPTION: DESIGN: \\� CONTAINED SHALL NOT BE USED FOR THE ROWE, AMY MEADOW RIDGE — LOT 76 Wubing Ye =��•• BENEFIT OF ANYONE EXCEPT IN WHOLE INC., MOUNTING SYSTEM: 36548 OBARIA WAY �• SolarCity NOR SHALL IT BE DISCLOSED E RECIPIENT'S OR IN ZEP ZS Tile FTile 5.2 KW PV ARRAY ��� PART IZ OTHERS OUTSIDE THE RECIPIENT'S MODULES LAKE ELSINORE CA 92532 ORGANIZATION, EXCEPT IN CONNECTION WITH i THE SALE AND USE OF THE RESPECTIVE (20) KYOCERA # KU2606XPA 3055 CleaNew Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE: San Mateo, CA 94402 PERMISSION OF SOLARgTY INC. INVERTER: 9512191556 T:(650) 638-1028 F:(650)638-1029 ABB PVI-4.2—OUTD—S—US—Z—A SITE PLAN PV 2 8/30/2015 (888)—SOL—CITY(765-2489) www.solarcity.com Ben L1LI �-- cmm) STAMPED & SIGNED FOR STRUCTURAL ONLY si .. �SS!ONq�FN� Lu Cn G1r1a 29 6'-6 3'-6„ 4'-4„ „ ' E 1 -3 ( ) LBW 1 3 STATE OF GPI , � � ,7 1 SIDE VIEW OFMP1 NTS A MP1 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 72" 24" PORTRAIT 48" 19" RAFTER 2x4 @ 24" OC ROOF AZI 190 PITCH 18 STORIES: 2 INSTALLATION ORDER ARRAY AZI 190 PITCH 18 ; " DIA THREADED STUD REMOVE TILE, LOCATE & MARK C.J. 2x4 @24" OC Flat Cement Tile & NUT (1) RAFTER LOCATION.PLACE STANDOFF BASE & DRILL PILOT HOLES. ZEP LEVELING FOOT _______ _ _____ ____ ________ ZEP TOP ARM 2) CLEAN PAPER AROUND PILOT HOLE. ZEP ANTI-ROTATION PLATE (6) M10 BOLTS SEAL PILOT HOLES AND BOTTOM OF MOUNTING BASE ��� ((3) STANDOFF WITH POLYURETHANE (E) TILE SEALANT. (E) ROOF DECKING 4) LAG STANDOFF BASE INTO RAFTER. (E) RAFTER !r(4) - (2) 1j" DIA STAINLESS (3) q SEALING PLACENG WITHNDSINGLEACH BOLT. STEEL LAG BOLT (2-1" EMBED, MIN) PLACE ZEP BAR. THEN INSTALL (6) LEVELING FOOT WITH BOLT & WASHER. CSI�_ STA DOFF Scale: 1 1/2" = 1' J B—9 2 5 814 2 0 o PREMISE OYMER: DESCRIPTION: DESIGN: CONFIDENTIAL - THE INFORMATION HEREIN J08 NUMBER: ROWE, AMY MEADOW RIDGE — LOT 76 Wubing Ye SolarCit CONTAINED SHALL NOT BE USED FOR THE _'- BENEFIT OF ANYONE EXCEPT IN MOLE INC., MOUNTING SYSTEM: 36548 OBARIA WAY 5.2 KW PV ARRAY NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP ZS Tile FTile PART OTHERS OUTSIDE THE RECIPIENT'S MODULES: LAKE ELSINORE CA 92532 ORGANIZATION, EXCEPT IN CONNECTION WITH �THE SALE AND USE OF THE RESPECnVE (20) KYOCERA # KU2606XPA 3055 gearview Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV: DATE: T:(650)Son Mate FA94402 638-1029 PERMISSION OF SOLARCITY INC. ABB # PVI-4.2—OUTD—S—US—Z—A 9512191556 STRUCTURAL VIEWS PV 3 8/30/2015 (aas)-SOL-CITY(765-2489) www.Worcity.com Ben Liu UPLIFT CALCULATIONSCD U L3- SEE SEPARATE PACKET FOR STRUCTURAL CALCULATIONS. CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: PREMISE OMER: DESCRIPTION, DESIGN, JB-9258142 00 Cit CONTAINED SHALL NOT BE USED FOR THE ROWE, A MEADOW RIDGE — LOT 76 Wubin 9 _t i BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: Ye Solar NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP ZS Tile FTile 36548 OBARIA WAY 5.2 KW PV ARRAY Y PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: LAKE ELSINORE, CA 92532 THE SALE AND USE OF THE RESPECTIVE (20) KYOCERA # KU2606XPA CIe°"I°""°Y SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME. SHEET: REV. DATE T:(650)Sm Male CA 94402 )638-1029 PERMISSION OF SOLARCITY INC. ABB # PVI-4.2—OUTD—S—US—Z—A 9512191556 UPLIFT CALCULATIONS PV 4 8/30/2015 (aaa)-SOL-CITY(765-2+89)www.adarcity.com GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO (E) LIFER AT PANEL Panel Number: Inv 1: DC Ungrounded INV 1 —(1)ABB # PVI-4.2—OUTD—S—US—Z—A LABEL: A —(20)KYOCERA # KU2606XPA CA # 888104 WITH IRREVERSIBLE CRIMP Meter Number: FCI Inverter; Zigbee 420OW, 240V, 96% PV Module; 260W, 232.9W PTC, 40MM, Blk Frame, H4, ZEP, 1000V, w/Bak C-10 Underground Service Entrance INV 2 13� t en Liu Voc: 38.3 Vpmax: 31 t INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 200A MAIN SERVICE PANEL E 20OA/2P MAIN CIRCUIT BREAKER CUTLER—HAMMER ADJUST MIN. ACTIVATION VOLTAGES! SolarCity Inverter 1 IND 4 A 1 Vstart = 200V 20OA/2P Disconnect 5 ABB DC• PVt-4.2—OUTD—S—US—Z—A DC- MP 1: 1x10 — EGC —————————————tp-ji(E) LOADS B —----------- -------- -- u 2aav JIF --------- �2Dc+N DG 3 2 Vstart = 200V 2SA/2P ——__ GND EGCI DC+ DC- A ------------------------------------- — GEC ---TN DC- G MP 1: 1x10 B GND EGC --——————---- ---�---- --- �--------------/---�—j. ---- I I �(I)Conduit Kit; 3/4' EMT N I I EGCIGEC Z Z C.D —_— GEC TO 120/240V SINGLE PHASE UTILITY SERVICE i i i i I CONNECT TO THE EXISTING GEC OR BY IRREVERSIBLE CRIMP TO EXISTING GROUND WIRE. Voc* = MAX VOC AT MIN TEMP POI (1)SOUARE D #HOM225 PV BACKFEED BREAKER B (1)CUTLER—HAMMER /DG221URB A (1)SdarCit 4 STRING JUNCTION BOX D� Breaker, 25A/2, 2 Spaces Disconnect; 30A, 24OVac, Non-Fusible, le, NEMA 3R 2z2 "RAGS, UNFUSED, GROUNDED —(1)CUTLER—HAMMER 1 DG03ONB Ground/Neutral it; 30A, General Duty(DG) �(1)AWG 110, THWN-2, Black (1)AWG #10, THWN-2, Black Voc* =434.02 VDC Isc =9.09 ADC (2)AWG 110, PV wire, 60OV, Blade Voc* =434.02 VDC Isc =9.09 ADC OIse(1)AWG #10, THWN-2, Red O (1)AWG #10, THWN-2, Red Vmp =310 VDC Imp=8.39 ADC O (1)AWG#10, Solid Bare Copper EGC Vmp =310 VDC Imp=8.39 ADC IIL�==LLL(1)AWG#10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=20 AAC (1)AWG #10, THHN/THWN-2, Green EGC —(1)AWG#8, THWN-2. Green EGC/GEC—(1)Conduit Kit; 3/4' EMT (1)AWG #10, THWN-2, Black Voc* =434.02 VDC Isc =9.09 ADC (2)AWG#10, PV Wire, 60OV, Blade Voc* =434.02 VDC Isc =9.09 ADC ® (1)AWG #10, THWN-2, Red Vmp =310 VDC Imp=8.39 ADC O ^' (1)AWG 110, Solid Bare Copper EGC Vmp =310 VDC Imp=8.39 ADC (1)AWG #10, THHN/THWN-2, Green EGC L� PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL — THE INFORMATION HEREIN J OBER: J B-9258142 �O ����� ■ CONTAINED SHALL NOT BE USED FOR THE ROWE, AMY MEADOW RIDGE - LOT 76 Wubing Ye SolarCity. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., SYSTEM: �'�,. NOR SHALL IT BE DISCLOSED IN WHOLE OR INZS Tile FTile 36548 OBARIA WAY 5.2 KW PV ARRAY o PART TO OTHERS OUTSIDE THE RECIPIENTS LAKE ELSINORE CA 92532 3055 Clearview Way ORGANIZATION, EXCEPT IN CONNECTION WITH i THE SALE AND USE OF THE RESPECTIVE KYOCERA # KU2606XPA PAGE NAME: SHEET: REV: DATE son Mateo, CA 94402 PERMISSIONEIENTatTMTHOUT THE WRITTEN 9512191556 PV 5 8 30 2015 T:(650)63a-1028 F:(650)638-1029 OF PM-4.2-OUTD-S-US-Z-A THREE LINE DIAGRAM / / (ase)—sa—aTY(765-2489)www.adorcity.com . - c ELECTRICAL CALCULATIONS String and 2 Combined Strings Module Type: Module Count: Icont= (Amps): Kyocera 260 1000V 20 11.36 Branch Circuit Individual MPPT 1 strings per Branch A 1 strings per Branch B 10 modules per series string 10 modules per series string String Branch A Branch B Conductor: Conductor: Conductor: Icont * 1.25 = (Amps) 14.2 14.2 14.2 30 deg C ampacity = 40 40 40 PV Wire Size: AWG #10 AWG #10 AWG #10 Icont = (Amps) 11.36 11.36 11.36 Start ampacity 40 40 40 Temperature derate (%=F) 031 0.71 0.71 Conduit fill derate (%=#) 1 0.8 0.8 Derated ampacity 28.4 22.72 22.72 Icont * 1.25 = (Amps) 14.2 14.2 14.2 Ampacity 40 40 40 Inverter Output Inverter Type: Inverter Count: Total ABB PVI-4.2-S AFCI 1 Icont= (Amps): 20 Icont* 1.25 = (Amps) 25 OCP Size-= 25 Conductor 3: AWG #10 THWN-2 Icont * 1.25 = (Amps) 25 30 deg C ampacity = 40 Icont = (Amps) 20 Start ampacity 40 Temperature derate (%=F) 0.91 Conduit fill derate Derated ampacity 36.4 Icont * 1.25 = (Amps) 25 Ampacity 35 Ben Liu L34k PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL A THE INFORMATION HEREIN NUMBER: J B-9258142 00 ROWE, AMY MEADOW RIDGE — LOT 76 Wubing Ye CONTAINED SHALL NOT E USED RCI THE SolarCity. BENEFIT OF ANYONE EXCEPT SOLARCITY INC.,: MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP ZS Tile File 36548 OBARIA WAY 5.2 KW PV ARRAY 'i�, PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES LAKE ELSINORE, CA 92532 THE SALE AND USE OF THE RESPECTIVE (20) KYOCERA # KU2606XPA _ 3055 ClearWew Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME SHEET: REV: DATE: T: 850 San Mateo, CA 94402 PERMISSION OF SOLARgTY INC. ABB PV1-4.2-OUTD—S-US-Z-A 9512191556 ELECTRICAL LOAD CALCULATIONS PV 8/30/2015 (888)SOL,CITY(69 2489)50www.solarcity.com CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: - Address: 36548 Obaria Way AC DISCONNECT r---- I r--------I - UTILIT �J SERVICE INVERTER AND DC DISCONNECT r----------------------- — SOLAR PHOTOVOLTAIC- ARRAYS) J PHOTOViOLTAIC BACK-FED gRCUIT BREAKER IN MAIN ELECTRICAL PANEL IS AN A/C DISCONNECT PER NEC 690.17 OPERATING VOLTAGE = 240V JB-9258142-00 PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN NUMBER: g-9258142 00 MEADOW RIDGE — LOT 76 Wubing Ye �\`�! CONTAINED SHALL NOT EXCEPT TSEO FOR THE ROWE, AMY �•�1O SolarCity BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP ZS Tile FTile 36548 OBARIA WAY 5.2 KW PV ARRAY ►�� PART TO OTHERS OUTSIDE THE RECIPIENTS THE BALE AND EXCEPT INHECNECTION RESPECTIVE 1H (20) KYOCERA # KU2606XPA LAKE ELSINORE, CA 92532 USE OF3055 Clearview Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET' REV. DATE: Son Mateo, CA 94402 PERMISSION OF SOLARCITY INC. INVERTER. 9512191556 T.(650)638-1028 F:(650)638-1029 ABB PVT-4.2—OUTD—S—US—Z—ASITE PLAN PLACARD PV 6 8/30/2015 (888)-SOL—CITY(765-2489)wwwWaraityaom WARNING:PHOTOVOLTAIC POWER SOURCE Label Location: .• • •n: Label Location: PV SYSTEM WARNING ' Per Code: DISCONNECT FOR ELECTRIC SHOCK HAZARD _ ••_ CRC R331.2UTILITY OPERATION THE DC CONDUCTORS OF THIS CEC • Label Location: PHOTOVOLTAIC SYSTEM ARETO BE USED WHEN UNGROUNDED ANDINVERTERIS PHOTOVOLTAIC DC D Code: MAY BE ENERGIZED DISCONNECTPer CEC .•0 .14.C.2 Label Location: WARNING ' Per ..- CEC ELECTRIC SHOCK HAZARD 690.17 Label • - • DO NOT TOUCH TERMINALS MAXIMUM POWER- TERMINALS ON BOTH LINE AND POINT CURRENT(Imp)_ Per Code:CEC LOAD SIDES MAY BE ENERGIZED MAXIMUM POWER- IN THE OPEN POSITION POINT VOLTAGE(Vmp)_V 690.53 MAXIMUM SYSTEM_V VOLTAGE(Voc) SHORT-CIRCUIT A CURRENT(Isc) ..-I Location: Per WARNING ..- INVERTER OUTPUT CONNECTION •- DO NOT RELOCATE WARNING Per THIS OVERCURRENT DEVICE ••- ELECTRICALSHOCK HAZARD DO NOT TOUCH TERMINALSCEC 690.17 TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITIONLabel L• • DC VOLTAGE IS PHOTOVOLTAIC POINT OF ALWAYS PRESENT WHEN INTERCONNECTION _ ••_ CEC SOLAR MODULES ARE EXPOSED TO SUNLIGHT WARNING: ELECTRIC SHOCK • 690.17 HAZARD. DO NOT TOUCH TERMINALS.TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION. FOR SERVICE LabelDE ENERGIZE BOTH SOURCE WARNING Per AND MAIN BREAKER. PV POWER SOURCE Code: CEC MAXIMUM AC A ELECTRIC SHOCK HAZARD 690.5(C) OPERATING CURRENT IF A GROUND FAULT IS INDICATED NORMALLY GROUNDED MAXIMUM AC V CONDUCTORS MAY BE OPERATING VOLTAGE UNGROUNDED AND ENERGIZED Label • • Label • - • CAUTION (D) (POI_ conn(AC): AC Duiits PHOTOVOLTAIC AC O_ PHOTOVOLTAIC SYSTEM •• DISCONNECT o• CIRCUIT ISBACKFED •�� •� : • Conduit ct (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Label Location: Label Location: (INV): Inverter With Integrated DC Disconnect MAXIMUM AC A CAUTION PO Center OPERATING CURRENT Per Code: DUAL POWER SOURCECode: Load ty Meter CEC I• MAXIMUM AC 690.54 SECOND SOURCE ISCEC _ OPERATING VOLTAGE _ VPHOTOVOLTAIC SYSTEMPointof Interconnection 1 1 1• • 1 1 • • 1 1' 1 • 1 • r • r r • 1San Mateo,CA 94402 r 1 •• 1 •1 I 1 Solar inverters Additional highlights: >.-.- - RS-485 communication interface stringABB inverters (for connection to laptop or data logger). — Integrated Arc Fault Detection and AM i Interruption(-A Version). r a gym-1 to I i. i i i Technical data and types Type code PVI-3.0-OUTD-US PVI-3.6-OUTD-US PVI-3.8-OUTD-US PVI-4.2-OUTD-US FC. Mechanical specifications Nominal output power 3000W 360OW - 3W0 380OW 420OW Maximum output power wattage 3000 3300' 3300' 3600 4000' 4000' 3300 4200' 4200' 4260 4600' 4600' w W W W W W W W W W W W Rated grid AC voltage 208V 240V 277V 208V 240V 277V 208V 240V 277V 208V 240V 277V Input side(DC) Number of independent MPPT channels 2 2 2 2 uio Maximum usable power for each channel 2000W 3000W 3000W 3000W Absolute maximum voltage(Vmax) 600V Start-up voltage(Vstart) 200V(adi.120-35OV) Full power MPPT voltage range 160-530V 120-530V 140-530V 140-530V Operating MPPT voltage range 0.7 x Vstart-580V(>=90V) Maximum current(ldcmax)for both MPPT in 20A 32A 32A 32A parallel Maximum usable current per channel 10A 16A 16A 16A Maximum short circuit current limit per 12.5A 20 OA 20.OA 20 oA channel i Number of wire landing terminals per channel 2 pairs ,,,z., -.u• Array wiring termination -- Terminal block,pressure clamp AWG10-AWG4 Output side(AC) Grid connection type 1— / Split 10/ 1 / Split- 1 O/ 10/ split- 10/ 1 / Split 10/ 2W 0/3W 2W 2W 0/3W 2W 2W 0/3W 2W 2W 0/3W 2W Adjustable voltage range Nmin-Vmax)N) 183 211- 244- 183 211 - 244- _183- 21 1 244- 183- 21 1 244- 228V 264V 304V 228V 264V 304V 228V 264V 304V 228V 264V 304V Grid frequency 60Hz Adjustable grid frequency range 57-60.51-1z Maximum current(I._.) 14.5 14.5 12.0 17.2 16.0 16 O 160 16.0 16.0 20.0 20.0 20.0 A_ Aar A, s A_--'_ A_ -A� .Ai,Ms.. A_. Aa Aaus A-S A_ Power factor >0.995 Total harmonic distortion at rated power <2 Yo This family of single-phase string The high-speed MPPT offers real- Highlights: Grid wiring termination type Terminal block,Pressure clamp,AWG10-AWG4 inverters complements the typical time power tracking and improved — Single phase and split phase output Input protection devices Reverse polarity protection Yes number of rooftop solar panels energy harvesting. grid connection. Over-voltage protection type Varistor,2 for each channel enabling home-owners to get the most The flat efficiency curve ensures high — Wide input range for increased PV array ground fault detection Pre start-up Riso and Dynamic GFDI(requires floating arrays) efficient energy harvesting for the size efficiency at all output levels allowing stringing flexibility. Output protection devices of the property. a consistent and stable performance — The high speed and precise MPPT Anti-Islanding protection Meets UL 1741/IEEE1547 requirements Over-voltage protection type Varistor,2(L 4/L G) across the entire input voltage and algorithm offers real time power Maximum AC OCPD Rating 20A , 20A 15A 25A _ 20A • 20A 20A 20A° 20 25A 25A 25A This inverter offers a dual input output power range. tracking and improved energy Efficiency section that processes two strings The transformerless operation gives the harvesting. Maximum efficiency 96.9% 97% 97% 97% CEC efficiency 96% with independent Multiple Power Point highest efficiency of up to 97.0%. — Outdoor NEMA 4X rated enclosure Operating performance Tracking(MPPT). The wide input voltage range makes for unrestricted use under any Night time consumption <0.6W , This is especially useful for rooftop the inverter suitable to low power environmental conditions. stand-by consumption <8w°„ Communication installations with two different installations with reduced string size. — Integrated DC disconnect switch User-interface 16 characters x 2 lines LCD display orientations from two sub-arrays This rugged outdoor inverter has been in compliance with international Remote monitoring(1xRS485 incl.) VSN700 Data Logger(opt.) oriented in different directions.(For designed to be a completely sealed Standards(-S Version). Environmental Ambient air operating temperature range 13°F to+140°F with derating above 122°F(WC) example: East and West unit able to withstand the harshest - - P Ambient air storage temperature range -a0°F 10+176°F(-40°C to+80°C) The dual input sections with environmental conditions. Relative humidity 0-100%RH condensing independent MPPT enable a more Acoustic noise emission level <50 db(A)@1m Maximum operating altitutde without derating 6560 ft(2000 m) optimal energy harvesting condition. Power and productivity 1 Capability enabied at nominal AC voltage and with sufficient DC power available for a better world 2 ABB Solar Inverters I Product Flyer for PVI-3.0/3.6/3.8/4.2-TL-OUTD fsO�af�lty ®pSolar Next-Level PV Mounting Technology SO�afClty ®pSolar Next-Level PV Mounting Technology . Zep System Components for tile roofs using replacement tiles Lammrq Fmt I I� A—W i I / Top Arm att ab � � M4xo1•Up'i NN•,lle � �_ ru,2�np..ne r+xmernp - Replacement S-Tile L i Part No.850-1435 .d -- -- Listed to UL 2703 - i M,.Routionplw _. ..1i` - N 14wnlm4 B•ae I Replacement W-Tile pw,.,M.•,,., Part No.850-1437 Listed to UL 2703 I, r uY �rr a„� Replacement Flat Tile t r Part No 850-1436 j Listed to UL 2703 w �`OMhAr/ i• Description rFq / PV mounting solution for concrete tile roofs QpMPp11 Works with all Zep Compatible Modules �- _ • Zep System UL 1703 Class A Fire Rating for Type 1 and Type 2 modules Auto bonding UL-listed hardware creates structual and electrical bond U� LISTED Tile Roof Attachment Kit Interlock Leveling Foot Part No.850-1434 Part No.850-1388 Part No 850-1397 Listed to UL 2582 Listed to UL 2703 Listed to UL 2703 Specifications • Designed for pitched roofs • Installs in portrait and landscape orientations lilt iJ • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 • Wind tunnel report to ASCE 7-05 and 7-10 standards i Zep System grounding products are UL listed to UL 2703 and ETL listed to UL 467 Zep System bonding products are UL listed to UL 2703 Engineered for spans up to 72"and cantilevers up to 24" Zep wire management products listed to UL 1565 for wire positioning devices Ground Zep Array Skirt,Grip,End Caps DC Wire Clip • Attachment method UL listed to UL 2582 for Wind Driven Rain Part No.850-1172 Part Nos.500-0113, Part No 850-1448 Listed to UL 2703 and 850-1421,850-1460, Listed UL 1565 ETL listed to UL 467 850-1467 zepsolar.com zepsolar.com Listed to UL 2703 This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar s sole warranty is contained in the written product warranty for This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely responsible for verifying the suitability of Zep Solar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. responsible for verifying the suitability of Zep Solar's products for each use.Specifications are subject to change without notice.Patents and Apps.zspats.com. 12 31 14 ZS for Replacement Tile Applications Cutsheet Rev 02.pdf Page: 1 of 2 12 31 14 ZS for Replacement Tile Applications Cutsheet Rev 02.pdf Page: 2 of 2 KU-60 1000V Series ELECTRICAL �PFCIFICATIONS MODULE ,CHARACTERISTICS :► Icy 0 C E R a K U 6 0 10 0 0 V Z SeriesStandard Test Conditions(STC) Cells per module 60(6 x 10) �� Dimensions: 65.43in 38.98in 1.57in KU255-6XPA KU260-6XPA 60, length/width/height (1662mm/990mm/40mm) Weight: 47.41bs(21.Skg) CUTTING EDGE TECHNOLOGY - - - -- ----- Pma 255 260 w As a pioneer with four decades of experience in theMEN V_ 30.8 31.0 V PACKAGING -)PECIFICATIONS development of photovoltaic systems, Kyocera drives the - market as a leading provider of PV products.We Im° 8 28 $39 Modules per pallet: 20 demonstrate our Kaizen philosophy,or commitment toNONE va 38.0 38.3 V Pallets per53'container. 36 continuous improvement, by setting the industry standard Pallet box dimensions: 66in/40in/43in in the innovation of best-in-class solar energy equipment. 1X 8.83 9.09 A length/width height (1675mm/1005mm/1055mm) MEMO P.„- +5/-0 +5/-0 % Pallet box weight: 10601bs(480kg) QUALITY BUILT IN Nominal Operating Cell • •UV-stabilized,anodized aluminum frame in black NOCT=800 ' /;�; ,73- •Supported by major mounting structure manufacturers NONE T_ 45 43 -c �T1` � � POTTED JUNCTION •Easily accessible grounding points on all four corners PTa 1s3 ta7 w EMOTION for fast installation NEENE v 27.7 27.9 v $ V•Proven junction box technology with 12 AWG PV wire CONNECTOR (_) e•) works with transformerless inverters r 6.61 6.71 A LABEL A A •Amphenol H4-UTX locking plug-in connectors INEENE V� 34.8 35.1 v provide safe,quick connectionsMENEM I 7.15 7.36 A PROVEN RELIABILITY PTc 228.3 232.9 w •Kyocera modules confirmed by the Desert Knowledge Temperature CoefficientsSTABILIZER BAR Australia Solar Centre to have the highest average INEENE - output of any crystalline module P_ 0.45 -0.45 %/-c to(ZBsO •First module manufacturer in the world to pass long- vm° -0.48 -0.48 %/°C term sequential testing performed by TUV Rheinland 1� 0.02 0.02 %/°C _ •Only module manufacturer to achieve the rank of "Performance Leader" in all six categories of GTM _ _ __ v� -0.36 -0.36 %/°c a8 se (990-) Research's 2014 PV Module Reliability Scorecard 0.06 0.06 %/-C "10 011", CERTIFICATIONS Operating Temp 40 to+90 -40 to+90 °C 6r•,raing H°le slotted[bunting Hot, 0.16'(Am) 0.3S"a0.47"(9-12 w) •UL1703 Certified and Registered,UL Module Fire System Design Performance:Type 2,CEC FRAME CROSS SECTION DIAGRAM •NEC 2008 Compliant,IEC 61215j61730,and ISO 14001 series Fuse Rating 15 A ,41' �ooMP'OT�o• Maximum DC System Voltage(UL) 1000 V � o aF Hailstone Impact in(25mm)@ 51 mp(23m/s) C(@us P 0 'Subject to simulator measurement uncertain of+; 3`-. A,AAllPIll VOCERA reserves the right to modify these specifieat'o^3 n. ... ., LONG/SHORT SIDE STABILIZER BAR NEC 2008 COMPLIANT WARNING:Road the II'str,1110, UL 1703 LISTEDL maraal in Its entirety prior to ,! haodOng,installing 8operat- 062614 Irg Kyocera solar mi OUR VALUED PARTNER HIGH EFFICIENCY MULTICIRYSTAL PHOTOVOLTAIC • • • KYOCERA Solar, :I• • :• :•• • fax www.kyocerasolar.com 0 ZepSolal ZS COMP I GROUNDING AND BONDING Zep nlar - --- - - Interlock ZS CompTM I Grounding and Bonding °ter`°`k:G This document describes the mechanics of how the electrical bonding is accomplished between the LIL Listed hardware components used in Zep Solar's ZS Comp mounting solution for composition shingle roofs. Part No.850-1388 Zep Compatible'"systems do not require running copper conductors to each module.The act of physically UL Listed to UL 2703 installing each component simultaneously establishes an electrical bond,as described in the following r -ung,eside pages. - Key Side Bonding Cutting"tooth` Side view \ Interlock Module Q ...., ..ei. Interlock(Key side shown) Keysidein 11- closed position Bonding locations Zep Compatible module - on Key side Forced interference duringrotation with Zep Groove Cutting"tooth" of Interlock Zep causes teeth to cut through anodization on module frame,resulting in robust and UL certified bonding path Tongue Side Bonding \ \ + Tongue side in closed position Leveling Foot O Module O Down-roof Pat ZS Comp Cutaway Illustration Cutting`teeth" Forced interference between mating parts from module Bonding location on rack-in motion cuts into module frame,removing Tongue side anodization and resulting in robust and UL certMed bonding path Document 800-1478-001 Rev A www.zepsolar.com Document 800-147E-001 Rev A www.zepsotar.com PA G E: 1 of 5 PAGE: 2 of 5 02013/EN Zep Solar,Inc Zep Solar reserves the right to make specifications chnages without any prior notice.ALI rights reserved. 02013/EN Zep Solar.Inc.Zep Solar reserves the right to make specifications chnages without any prior notice.All rights reserved. Date Last Exported:June 25.20134:45 PM Date Last Exported:June 25,2013 4:45 PM Zep Solar ZS COMP I GROUNDING AND BONDING ZepSolal ZS COMP I GROUNDING AND BONDING Interlock, continued Leveling Foot Tongue side a ————— Key side Spring clip Part No.850-1388 UL Listed to UL 2703 Bondin Path — KeV and Ton Ue Part No 850-1397 The Leveling Foot top portion(the Rockit)has a stainless steel 9 7 g UL Listed to UL 2703 spring clip that bonds to the adjacent module frame on both The Interlock bonds modules on all 4 sides to create a hyper- Key and Tongue sides. bonded array where every module is structurally and electrically bonded to the surrounding modules. Leveling Foot- Bonding With Module Frame Module - - - IV ` Tongue side Down roofli 2 O Interlock M Key side W 1 Key side inserts into Zep Groove(rock-in) Module in next row drops in on the Tongue side Bonding Path - Array Bonding Path - North and South Modules ® Interlock Bonding location on Keyside ti •,A Bonding path ® ® O . Leveling Foot _ ® ® I C ® ® Bonding path z _ -➢ T � - - ^ ;- ` �,•' '^- Bonding location on Module rotation during drop-in creates forced ' - Down-roof Tongue side interference between Zep Groove and spring clip, Down-roof cutting into module frame,removing anodization and resulting in robust and UL certified bonding path Document 800-1478-001 Rev A www.zepsolar.com Document 800-1478-001 Rev A www.zepsolar.com PAGE: 405 PAGE: 3Df5 02013 02013/E N Zep Solar,Inc.Zep Solar reserves the right to make specifications chnages without any prior notice.All rights reserved. /EN Zep Solar,Inc.Zep Solar reserves the right to make specifications chnages without any prior notice.All rights reserved Date Last Exported:June 25,20134:45PM Date Last Exported.June 25.2013 4.45 PM ZepSok,,i ZS COMP I GROUNDING AND BONDING Ground Zep Set screw /Key side _ The Ground Zep provides a single point of connection for the Equipment Grounding Conductor(EGC)from the array to a building ground. \ - Ground wire channel Part No.850-1172 UL Listed to UL 467 and UL 2703 Ground Zep Installation Insert Ground Zep into Zep Groove of module frame, Use the Flat Too to rotate the Ground Zep 90 degrees,so that set screw Insert copper EGC into ground wire - on array perimeter is pointing straight up. channel.Tighten set screw using torque values shown in the ZS Comp Installa- tion Manual. Bonding Path - Array to Ground OGround Zep Equipment Ground �— Conductor !' Bonding path Down-roof r Document 800-1478-001 Rev A www.zepsotar.com PAGE: 5 of 5 ®2013/EN Zep Solar,Inc.Zep Solar reserves the right to make specifications chnages without any prior notice.All rights reserved. Date Last Exported:June 25,2013 4:45 PM SolarCity Standard Box 4J NOTICE OF COMPLETION AND AUTHORIZATION TO APPLY THE UL MARK The SolarCity Standard Box 4J is a • Manufactured to meet UL 1741 Standards. 1 212 1/20 1 3 4-String unfused Junction Box. The box Solarcity Corp • Non-Metallic, Corrosion Resistant NEMA 4X Enclosure. Alex Yang is highly configurable and adaptable 3055 Clearview Way using the(4)jumper blocks included in •Factory-Installed Cordgrip Enhances Installation Speed. San Mateo Ca 94402-3709,Us each box. A factory installed Cordgrip •Break-Thru Skinned-Over Glands on Cordgrip Provide enhances Installer productivity. Weathertight Seal for All Configurations. Our Reference: E318537,Volume 1 Project Number 4786083586 •Easily Configurable Terminal Blocks Permit Adaptation Your Reference: A.Yang 10/7 Project Scope: Investigation of Photovoltaic(PV)System Combiner Box,model"SolarCity Standard Box 4C" to Site-Specific Stringing Needs. and Photovoltaic(PV)System Transition Box,model"SolarCity Standard Box 4X to UL 1741 Standard. Dear Alex Yang: Technical Data / Specifications Congratulations! Li investigation of your product(s)has been completed under the above Reference Number and the product was determined to comply with the applicable requirements. This letter temporarily supplements the UL Follow-Up Services Procedure and serves as authorization to apply the UL Mark at authorized factories under UL's A Voltage Rating [VDC] :600V Follow-Up Service Program. To provide your manufacturer(s)with the intended authorization to use the UL Mark, you must send a copy of this notice to each manufacturing location currently authorized under E318537,Volume 1 ® B Maximum DC Current[A]:57A and including any special instructions as indicated in the addendum to this letter. 1 40 C Maximum Continuous Current[A]:42A Records in the Follow-Up Services Procedure covering the product are now being prepared and will be sent in the ?, D Maximum Voltage[VDC]: 600V near future. Until then,this letter authorizes application of the UL Mark for 90 days from the date indicated above. E Wire Size Range[AWG]: #6 to#14 Additional requirements related to your responsibilities as the Applicant can be found in the document"Applicant responsibilities related to Early Authorizations"that can be found at the following web-site: o _ _ _ _ - _ _ F Enclosure Rating: NEMA 4X htlD:/twww.ul.com/EAResoonsibilities y O:4400 y y G Operating Temperature Range[°C]:-40 to 50 Any information and documentation provided to you involving UL Mark services are provided on behalf of UL LLC H Typical Overall Dimensions[in]:8"x6"x4" (UL)or any authorized licensee of UL. j We are excited you are now able to apply the UL Mark to your products and appreciate your business. Feel free to ' contact me or any of our Customer Service representatives if you have any questions. Very truly yours, Reviewed by: Jon Adonay William R.Carney 408-754-6630 847/664-1088 Engineering Associate Lead Chief Engineer Director I Jon.Adonay@ul.com William.R.Carney@ul.com NBKD9C5-90BA67 SolarCity® October 2013 This is an electronically generated letter Signatures are not required for this document to be valid. Page 1 of 1