Loading...
HomeMy WebLinkAboutMINTHORN STREET 18520_14-00001268 Lake Elsinore Fire Protection Planning 130 S. Main St. • Lake Elsinore, California 92530 C["I (951) 674-3124 Ext. 225 • Fax (951) 471-1491 ` Dbloom@Lal<e-Eisinore.Org _- C.>R.E J�M ( ; 1'EZ E.ivt E PERMIT PERMIT NO: 14-00001268 DATE: 5/19/14 JOB ADDRESS . . . . . 18520 MINTHORN ST DESCRIPTION OF WORK FIRE SERVICES OWNER CONTRACTOR ADVANCED INV OWNER 4741 E HUNTER AVE STE C ANAHEIM, CA 92807 A. P. # . . . . . 377-151-045 1 SQUARE FOOTAGE 0 OCCUPANCY . . . GARAGE SQ FT 0 CONSTRUCTION . . FIRE SPRNKLR VALUATION . . . ZONE . . . . . . M-1 FIRE SERVICES QTY UNIT CHG ITEM CHARGE 1 . 00 X 168 . 0000 LE FIRE MISC 168 . 00 FEE SUMMARY CHARGES PAID DUE PERMIT FEES FIRE SERVICES 168 . 00 . 00 168 . 00 TOTAL 168 . 00 . 00 168 . 00 f t Tjpe; IF Dma-. 1 Datc 19/14 19 ipt : 276 2014 1 Bp BJILDIW PERMIT 1. 16&00 Try date. 5/1 14 Tire: 13=00 City of Lake Elsinore Please read and initial Fire Services Division _ 1. 1 am Licensed under the provisions of Business and professional Code Section 7000 et seq.and POSt in conspicuous place my license is in full force. On the job 2. [,as owner of the property,or my employees w/wages as their sole compensation will do the work You must furnish PERMIT NUMBER and the and the structure is not intended or offered for sale. JOB ADDRESS for each respective inspection: _3. l,as owner of the property,am exclusively contracting with licensed contractors to construct the Approved plans must be on is proiect. i at all times: _4. 1 have a certificate of consent to selfinsure or a certificate of Workers Compensation Insurance Inspection request(95 1) 674-3124 ext. 225 I or a certified copy thereof. 5. 1 shall not employ any person in any manner so as to become subject to Workers Compensation Laws in the performance of the work for which this permit is issued. Note: If you should become subject to workers Compensation after making this certification, Code Approvals Date Tnspector you must forthwith comply with such provisions or this permit shall be deemed revoked. Sprinkler System Start Time Finish Time SKO 1 UG Thrust Block PrePour l SK02 Underground Rough/I-lydro a 01',V- _ 1 -f J diliY 'UIIIlGl glUUt1U F1USn '.. SK05 Weld Inspection SK06 Overhead Rough/Hydro SK99 10verhead Final NS K6�Fligh Pile Storage(FPE)r a k.11n In-Rack C rnnUlers 1 SKI 0 Hose Racks SK03 °T tic 19 Verficatiorl —-- SK07 Bell/Main DrainlCNtTC Hydrant System Date Inspector HSO I U.G.Thrust Block Pre-Pour FIS02 Underground Rough/Hydro HS03 Underground Flush T IIS99 Final/Signs/CMTC _ Knox System Date Inspector i KSO1 Knox Rapid Entry 4 mire"'Wrm Sysrems Date' Inspector- - - FAOI Fire Alarm Wiring Insp. FA02 Fire Alarm Function Test FA03 Fire Alarm 24 Fir Battery FA99 Fire Alarm Final FA05 ISprinkler Monitoring Fuel Storgae Tanks Date Inspector FT01 Underground Tank(S) FT02. Aboveground'fank(S) FT03 Fuel Dispensers Only Building Inspections Date Inspector FT99 T/I Final FS99 Shell Final Misc.Inspections Date Inspector MIO I Spray Booths MI02 Flood/Duct Suppression M103 High Pile/Rack Storage MI04 FIT.Vents/.Access/Core MI05 Haz-Mat Verification M106 Otherl%cA*larv,{er,_. CITY of ., Lake Elsinore Fire Protection Planning i Cc 1 30 S. Main St. • Lake Elsinore, California 92530 L--� LJII`�ORE (951) 674-3124 Ext. 225 • Fax (951) 471-1491 �` . . DREAM FXHUME Dbloom@Lake-Elsinore.Org � 's 00 PERMIT APPLICATION FORM Permit No. o 6 F Project Name: 01a �w--I aor M I understand that after the second submittal and after Project Address: .O `k YA )o r V-) failed inspections that additional fees will be required. City & Zip: La�<o E`sk n co re, CR g(D-53 CCApplicant Sign: �ay�-m � z V—eja_ Date: -5- i5- Contact Information CONTACT PERSON: Company Name: Phone No: E-mail Address: _ Plan Review Type Check appropriate items ❑ Commercial Industrial ❑ Residential ❑ Special Event ❑ Other ❑ Building ❑ Building Tenant Improvement ❑ High Fire Area ❑ Underground Water ❑ Sprinkler System ❑ TI Sprinkler System ❑ Sprinkler Monitoring ❑ Fire Alarm System ❑ Hood & Duct Suppression System ❑ Other Suppression System ❑ Spray Booth ❑ Cell Site ❑ High Pile/Racks ❑ Other: Storage Tank Submittals: ❑ Dispensers Only ❑ Above Ground ❑ Underground SubmittalOfficial Use Only Received Date: �5-/q -/(-/ Reviewed by: PC Review Date: Plans: ❑ Approved ❑ Denied Letter Attached: ❑Yes ❑No Job Card Included: ❑Yes ❑No Called for Pick-Up: Picked-Up Date: By: Date Date Applicant Sign Submittal Official Use Only Received Date: Reviewed by: PC Review Date: Plans: ❑ Approved ❑ Denied Letter Attached: ❑Yes ❑No Job Card Included: ❑Yes ❑No Called for Pick-Up: Picked-Up Date: By: Date Date Applicant Sign Resubmittal Fee Paid Date: SubmittalOfficial Use Only Received Date: Reviewed by: PC Review Date: Plans: ❑ Approved ❑ Denied Letter Attached: ❑Yes ❑No Job Card Included: ❑Yes ❑No Called for Pick-Up: Picked-Up Date: By: Date Date Applicant Sign Resubmittal Fee Paid Date: Visit us at www.lake-elsinore.org Lake Elsinore Fire Protection Planning Fees These are Flat Fees but there may be additional resubmittal & inspection fees based on corrections. Resubmittal & Reinspection Fee $168.00 Checks or Money Orders are to be made payable to: City of Lake Elsinore Plans are reviewed in the order they are received. Plan Review/Inspection Plan Fee Sets Building 2 $1,056.00 (<50K) $528.00 each add 50K Tenant Improvement Building 2 $696.00 Tenant Improvement Building (Under 5,000 sq. ft.) 2 $348.00 Water y�P ans 2 $614.00 Fire Sprinkler (per head) 3 (<100) $614.00 (100-Riser) $921.00 (20 or less) $307.00 Tenant improvement Sprinkler 3 (21-100) $614.00 (100-Riser) $921.00 Residential Sprinkler 3 Plan Check$454.00Insp. $210.00 $672 (1-10 Ini. Dev) Fire Alarm System 3 $1008 (11-20 Ini. Dev) $1344 (20<ini. Dev) Sprinkler Monitoring System 3 $454.00 Suppression Systems 3 $454.00 Cell Tower Review(Generator/Batteries) 3 $348.00 r%UUVt="round Fuel Storage T ank kill Lank 3 y g t / $584.00 - Each additional tank $168.00 High Pile or Rack Storage 3 $348.00 Fire Flow Report 1 $178.00 Technical Report-(FPE/Haz-Mat) 2 $1008.00 Items not listed above are on a sliding scale starting at $168.00- Up Single Family Residential Review 2 $75.00 After hours Inspections $168.00 per/hr. 2 hr. min. (When available) 33 Ut w oO a z z J J 0 � 0 0 l0 Q 0 E:q Z 0 LLJ O 0 m m Q` z O LL 0 O m d Q` O m U § s§ rc G O �a 4 AFAKORI WELDING INC. 18520 MINTHORN ST. LAKE ELSINORE CA, 92520 Gases stored within the premises as follows: • Acetylene dissolved,4 tanks (110 c.f. ea.) • Oxygen compressed, 6 tanks (3 ea. at 150 c.f. and 3 ea. at 275 c.f.) • Compressed gas N.O.S. (75%argon, 25%carbon dioxide), 7 tanks (4 ea. at 300 c.f. and 3 ea. at 200 c.f.) • Argon compressed, 3 tanks (60 c.f. ea.) Propane, 3 ea. forklift size tanks and 1 ea. small one. Welding and cutting processes performed at premises as follows: • Flux cored arc welding, (FCAW) • Gas metal arc welding, mig (GMAW) • Tungsten inert gas welding, tig (GTAW) • Arc welding (SMAW) • Oxy-acetylene torch cutting. RNE M COUNTY , NT IN COOPERATION WITH THE CALIFORNIA DEPARTMENT OF FORESTRY AND FIRE PROTECTION 2300 Market St., Ste. 150 Riverside, California 92501 (951) 955-4777 e Fax (951) 955-4886 77-933 Las Montanas, Palm Desert, CA 9221 1 (760) 863-8886 ® Fax (760) 863-7072 Inspection Hotline (951) 955-5282 www.rvcfire.org RIOT WORK OPERATING PERMIT PERMIT #: 14-1268 DATE OF ISSUE: 6-6-2014 JOB: AFAKORI WELDING ADDRESS: 18520 MINTHORN, LAKE ELSINORE TO: LUZ AGREDA TENANT: AFAKORI INC PHONE: 951-245-1707 E-MAIL: INFO@AFAKORI.COM REV/EWED BY.'D. BLOOM DATE.' 6-6-2O14 TERMS AND CONDITIONS THIS PERMIT CONSTITUES PERMISSION TO MAINTAIN, STORE, USE OR HANDLE MATERIALS, OR TO CONDUCT PROCESSES WHICH PRODUCE CONDITIONS HAZARDOUS TO LIFE OR PROPERTY; OR TO INSTALL EQUIPMENT USED IN CONNECTION WITH SUCH ACTIVITIES PROVIDED THE FIRE DEPARTMENT CONDITIONS LISTED BELOW ARE MET AND MAINTAINED IN ACCORDANCE WITH CALIFORNIA FIRE CODE, APPLICABLE REFERENCED STANDARD, AND/OR CONDITIONS OF APPROVAL AS SET FORTH BY THIS DEPARTMENT. SUCH PERMISSION SHALL NOT BE CONSTRUED AS AUTHORITY TO VIOLATE, CANCEL. OR SET ASIDE ANY OF THE PROVISIONS OF THIS OR ANY OTHER CODE. THIS PERMIT SHALL NOT TAKE THE PLACE OF ANY LICENSE REQUIRED BY LAW. PERMIT APPLICANTS AND THE APPLICANTS' AGENTS AND EMPLOYEES SHALL CARRY OUT THE ACTIVITIES AS LISTED BELOW IN COMPLIANCE WITH THE INTERNATIONAL FIRE CODE AND OTHER LAWS OR REGULATIONS APPLICABLE THERETO, WHETHER SPECIFIED OR NOT, AND IN COMPLETE ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. SAID CALIFRNIA FIRE CODE SHALL BE 2013 EDITION AS ADOPTED BY THE LAKE ELSINORE MUNICIPAL CODE. THIS PERMIT SHALL BE KEPT ON THE PREMISE(S) DESIGNATED ABOVE AT ALL TIMES AND SHALL BE POSTED IN A CONSPICOUS LOCATION ON THE PREMISE(S) AND SHALL BE SUBJECT TO INSPECTION AT ANY TIME ON DEMAND OF AN OFFICER OF THE FIRE DEPARTMENT OR ANY PEACE OFFICER OR OTHER PERSONS AS DESIGNATED BY THE CHIEF OF THE FIRE DEPARTMENT. 1 SPECIFIC OPERATING REQUIREMENTS AND CONDITIONS Hot Work 2601.3 RESTRICTED AREAS- 1. Areas where there exists the potential of an explosive atmosphere, such as locations where flammable gases, liquids or vapors are present. 2. Areas with readily ignitable materials, such as storage of large quantities of bulk sulfur, baled cotton, lint, dust or loose combustible materials. 2603.3 Hot work program permit- Hot work permits, issued by an approved responsible person under a hot work program, shall be available for review by the fire code official at the time the work is conducted and for 48 hours after work is complete. 2603.4 Qualifications of operators-A permit for hot work operations shall not be issued unless the individuals in charge of performing such operations are capable of performing such operations safely. Demonstration of a working knowledge of the provisions of this chapter shall constitute acceptable evidence of compliance with this requirement. 2603.5 Records- The individual responsible for the hot work area shall maintain "prework check" reports in accordance with Section 2604.3.1. These reports shall be maintained on the premises for a minimum of 48 hours after work is complete. 2603.6 Signage-Visible hazard identification signs shall be provided where required by Chapter 27. Where the hot work area is accessible to persons other than the operator of the hot work equipment, conspicuous signs shall be posted to warn others before they enter the hot work area. Such signs shall display the following warning: CAUTION HOT WORK IN PROGRESS STAY CLEAR. 2604.1 Protection of combustibles- Protection of combustibles shall be in accordance with Sections 2604.1.1 through 2604.1.9. 2604.1.1 Combustibles- Hot work areas shall not contain combustibles or shall be provided with appropriate shielding to prevent sparks, slag or heat from igniting exposed combustibles. 2604.1.2 Openings- Openings or cracks in walls, floors, ducts or shafts within the hot work area shall be tightly covered to prevent the passage of sparks to adjacent combustible areas, or shielded by metal fire-resistant guards, or curtains shall be provided to prevent passage of sparks or slag. 2604.1.3 Housekeeping- Floors shall be kept clean within the hot work area. 2604.1.5 Partitions- Partitions segregating hot work areas from other areas of the building shall be noncombustible. In fixed hot work areas, the partitions shall be securely connected to the floor such that no gap exists between the floor and the partition. Partitions shall prevent the passage of sparks, slag, and heat from the hot work area. 2604.1.6 Floors- Fixed hot work areas shall have floors with noncombustible surfaces. 2604.1.7 Precautions in hot work- Hot work shall not be performed on containers or equipment that contains or has contained flammable liquids, gases or solids until the 2 containers and equipment have been thoroughly cleaned, inerted or purged; except that "hot tapping" shall be allowed on tanks and pipe lines when such work is to be conducted by approved personnel. 2604.1.9 Fire detection systems-Approved special precautions shall be taken to avoid accidental operation of automatic fire detection systems. 2604.2 Fire watch- Fire watches shall be established and conducted in accordance with Sections 2604.2.1 through 2604.2.6. 2604.2.1 When required-A fire watch shall be provided during hot work activities and shall continue for a minimum of 30 minutes after the conclusion of the work. The fire code official, or the responsible manager under a hot work program, is authorized to extend the fire watch based on the hazards or work being performed. Exception: Where the hot work area has no fire hazards or combustible exposures. 2604.2.2 Location- The fire watch shall include the entire hot work area. Hot work conducted in areas with vertical or horizontal fire exposures that are not observable by a single individual shall have additional personnel assigned to fire watches to ensure that exposed areas are monitored. 2604.2.3 Duties- Individuals designated to fire watch duty shall have fire-extinguishing equipment readily available and shall be trained in the use of such equipment. Individuals assigned to fire watch duty shall be responsible for extinguishing spot fires and communicating an alarm. 2604.2.4 Fire training- The individuals responsible for performing the hot work and individuals responsible for providing the fire watch shall be trained in the use of portable fire extinguishers. 2604.2.6 Fire extinguisher-A minimum of one portable fire extinguisher complying with Section 906 and with a minimum 2-A:20-B:C rating shall be readily accessible within 30 feet (9144 mm) of the location where hot work is performed. 2604.3 Area reviews- Before hot work is permitted and at least once per day while the permit is in effect, the area shall be inspected by the individual responsible for authorizing hot work operations to ensure that it is a fire safe area. Information shown on the permit shall be verified prior to signing the permit in accordance with Section 105.6. 2604.3.1 Pre-hot-work check-A pre-hot-work check shall be conducted prior to work to ensure that all equipment is safe and hazards are recognized and protected. A report of the check shall be kept at the work site during the work and available upon request. The pre-hot-work check shall determine all of the following: 1. Hot work equipment to be used shall be in satisfactory operating condition and in good repair. 2. Hot work site is clear of combustibles or combustibles are protected. 3. Exposed construction is of noncombustible materials or, if combustible, then protected. 4. Openings are protected. 5. Floors are kept clean. 3 6. No exposed combustibles are located on the opposite side of partitions, walls, ceilings or floors. 7. Fire watches, where required, are assigned. 8. Approved actions have been taken to prevent accidental activation of suppression and detection equipment in accordance with Sections 2604.1.8 and 2604.1.9. 9. Fire extinguishers and fire hoses (where provided) are operable and available. 2605.3 Precautions- Cylinders, valves, regulators, hose and other apparatus and fittings for oxygen shall be kept free from oil or grease. Oxygen cylinders, apparatus and fittings shall not be handled with oily hands, oily gloves, or greasy tools or equipment. 2605.5 Remote locations- Oxygen and fuel-gas cylinders and acetylene generators shall be located away from the hot work area to prevent such cylinders or generators from being heated by radiation from heated materials, sparks or slag, or misdirection of the torch flame. 2605.6 Cylinders shutoff- The torch valve shall be closed and the gas supply to the torch completely shut off when gas welding or cutting operations are discontinued for a period of 1 hour or more. 2605.7 Prohibited operation- Welding or cutting work shall not be held or supported on compressed gas cylinders or containers. 2605.8 Tests- Tests for leaks in piping systems and equipment shall be made with soapy water. The use of flames shall be prohibited for leak testing. 2609.7 Inspection- Hoses shall be inspected frequently for leaks, burns, wear, loose connections or other defects rendering the hose unfit for service. y Fire Safety Specialist Date Owner/Tenant Date H �JZ (Print Name) By Fire Systems Inspector Date b"s (Print Name) 4