Loading...
HomeMy WebLinkAboutTR 35337 HYDROLOGY REPORT-015 Spyglass Ranch Tract 35337 Hydrology Study It may be observed that there is a slight difference between the total developed condition drainage area and the total existing condition drainage area (i.e. 313.91 vs. 307.65 acres). The minor difference is attributed primarily to the proposed offsite grading slope areas and is accounted for in Figure 4. TOTAL Dev. (Stage 7) drainage Area: TOTAL Ex. drainage Area: 373.970c 307.65ac +1.38aC +0.26ac +0.28ac 315.29ac +1.27ac +0.29ac +5.54aC Exist. & Dev. (s9) Drofnoge Boundary 315.29ac I Exist. Drainage Developed Drainage Boundary Boundary difference I I +0.26ac Dev. � +1.27ac Dev, +5.54ac Dev. I +0.29oc Dev. +1.38ac Exist. \�\ / +0.28ac Dev. Figure 4: Stage 1 (S1) Developed vs. Existing Drainage Area Balance No Scale Table 3 identifies only those drainage areas that are different in the Ultimate condition. All other drainage areas remain the same from the Stage 1 to Ultimate condition scenarios. Table 3: Rational Method Summary - Ultimate Condition Variable Areas Developed Dev Ex. Condition Area Equiv. Existing Developed Existing Total Total (Ultimate) Condition Area Q(100yr) Q(100yr) Area Area (Ac) (ac) C 1 41 1 133.521 155.0 1 44.67 1 53.56 D 19 1 69.7 86.1 27.59 29.81 R: \265324\Final\llydrology\Report\324 Report Body.doex