Loading...
HomeMy WebLinkAboutTR 28214 SIP PLAN NO 17-026 POS CONSTRUCTION NOTES COTJNTY ROUTE TTOTAL P A ZCTT y TOTAL PAOdSCT CONTRACTOR TO PURCHASE NEW STATE-FURNISHED (PURCHASE FROM STATE) MODEL 2.070E /R/V /5 26.46126.69 SIGNAL CONTROLLER WITH A 2070-6D MODEM AND INSTALL IN NEW TYPE 332 CONTROLLER INTERIM SIGNAL PHASE DIAGRAM CABINET PER CALTRANS STD PLAN ES-3C. FURNISH AND INSTALL NEW GPS TIME SOURCE AND CONDUCTOR SCHEDULE ANTENNA, TWO (2) SIERRA WIRELESS AIRLINK GX440 MODEM AND IT'S COMPONENTS INCLUDING EQUIPMENT SCHEDULE ALL CABLES, POWER SUPPLY AND TWO (2) ANTENNAS. FURNISH AND INSTALL RACKPRO SERIES P CONDUIT SITE AND RUN AWG SIZE p NOT useo POLE DATA L.E.D. SIGNAL HEADS AND MOUNTINGS *POLE LOC. MULTI-STAGE RECEPTACLE PROTECTION, RATED (15A, 725 VOLT-60HZ TYPE 3 SUPPRESSED OR PHASE - + SIGNAL R.S.N.S. VOLTAGE), 400V(LINE TO NEUTRAL), 500 VOLTS (LINE TO GROUND), 400 VOLTS (NEUTRAL TO CABLE TYPE L NO. TYPE HEIGHT M.A. M.A. WATTS VEHICULAR M.A. PEDESTRIAN "B" "E" "C" GROUND). FURNISH AND INSTALL NEW VIDEO DETECTION UNIT WITH REMOTE ACCESS CARD WITH E 1 ®© + E 7 01 02 03 04 MULTI DISPLAY PORT, 17-INCH RACKED MOUNTED LCD MONITOR DRAWER AND CABLING AND 2 2 2 - - - jol"i A 26-4-100 30' 30' 15,0 165 SV-2-TA 2FMzAS _ _ 22' 4' 1-15 SB OTHER EQUIPMENT NECESSARY FOR INTENDED OPERATION. FURNISH AND INSTALL NEW NO.14 CABLE A 01,04,06 - - -ETHERNET FIBER SWITCH (COMPATIBLE WITH CALTRANS D8 TMC NETWORK), ETHERNET TO p CB 04 - i t*i 1* - - - w --- 1-A 10' - - - TV-1-T - - 75' S' N Z O _ 1 _ _ NOT USED NOT USED NO7 USED SERIAL TERMINAL CONVERTER (FSK-NO FIBER), ETHERNET ROUTER (NO FIBER), AND PATCH 7 O NDC06 - 1* - - C 15TS 30' - 15• 165 SV-1-T - - 10' - 14'CABLES& CONNECTORS. TERMINATE 12 SMFO (CALTRANS TYPE D FIBER) ON FIBER OPTIC T UO2.04 - - - - - _ _TU/FDU WITH SPLICE TRAY (19" tU RACK MOUNTED WITH SC CONNECTORS HOUSING MODULE). E 04 - - - _ - 0 06 07 08 D 19-4-100 1 30, 25' 15'• 165 SV-2-TA MAS 4' 11' -15 SB NSTALLATION OF CABINET SHALL BE INSTALLED AS PER CALTRANS STANDARD PLANS 2015. R 3 0 _ 1 _1 _1 _ _ R F 01,02 - - E 17-3-100 30' 20' 75' 165 SV-1-T MAS 23' 3' LakStCONTRACTOR TO PURCHASE NEW STATE-FURNISHED BATTERY BACK-UP SYSTEM TO BE PAID TOTAL CABLES - 12 CON / 3 CON 2 _3 1*4 1 _2 _2 _ _ _ - BY PERMITTEE. CONTRACTOR TO FURNISH AND INSTALL BATTERY AND EXTERNAL CABINET F i5T5• 30' 15'� 165 SV-2-TA 33' 3' ENCLOSURE. INSTALL STATE-FURNISHED BATTERY BACK-UP SYSTEM IN EXTERNAL CABINET #8 GROUND 1 1 1 1 1 1 i ALL EQUI IS NEW. ENCLOSURE. #10 LUMINAIRES 2 2 2 2 2 2 - •INSTALL STRAIGHT/FLAT LUMINAIRE ARM. 01 - - 1 - - - 1 *-EXACT POLE LOCATION TO BE DETERMINED BY ENGINEER IN THE FIELD. 02 1 1 1 1 POTHOLE POLE FOUNDATION LOCATIONS PRIOR TO INSTALLING POLES. Q FURNISH AND INSTALL 120V/240V TYPE III-CF SERVICE ENCLOSURE AND FOUNDATION AS 04 2 2 2 - - - 2 DETAILED IN 2015 STD PLAN ES-2F AND ES-2C AND WITH TYPE V PEC. TYDEC"B 06 - - 1 - - - 1 METER A CTID XX-XX-XXX-O-XX.XX: 24OV, 100A, 2P,MAIN CB TOTAL 2 2 4 1 1 1 5 SERVICE ADDRESS: XXXXXXXXXXX 120V 50A, 1P SIGNALS CB(METERED) VIDEO COAXIAL CABLE 1 1 1 - 1 1 3 O,� 120� 20A, 1P VIDEO _ (2 LOOPS) 6 `D F RA.�jp w VIDEO POWER CABLE 1 1 1 1 1 3 v _(o METER B CTID XX-XX-XXX-O-XX.XX: 24OV, 100A, 2P, MAIN CB EVPE 1 1 1 - 1 1 3 v 1 *CF SERVICE ADDRESS: XXXXXXXXXXXX 120V 30A, IR LTG CB�MEERED) 13% 18% 23% 5% 13% 13%23% #5T �� ' 120�I, iSA, iP,LTG CIXd'I KKOL CB PERCENT FILL NEW 2"C., 2 DLC CONDUIT SIZES (INCHES) 4" 4" 4" 4" 4" 4" -4 OR 0cINSTALL 3" CONDUIT WITH PULLRGPE PER SCE REQUIREMENTS. SERVICE CONDUCTORS TO BE ALL CONDUIT AND CONDUCTORS ARE NEW. ?PROVIDED BY SCE: AT LEAST 48 HOURS ADVANCE NOTICE SHALL BE GIVEN TO SOUTHERN CALIFORNIA EDISON COMPANY BY CONTACTING DALE NELSON. AT(954) 219-3493. FOR FUTURE USE. DY I=FURNISH AND INSTALL ITERIS OR CALTRANS APPROVED EQUAL VIDEO DETECTION CAMERA ON SIGNAL MAST ARM/LUMINAIRE ARM PER MANUFACTURER'S RECOMMENDATIONS, DETECTION ©GA PHASE(S) AS NOTED. INSTALL ALL NECESSARY HARDWARE AND SOFTWARE IN CONTROLLER FOR NEW 2"C., 2 DLC / INTENDED OPERATION. PROVIDE SURGE PROTECTION PANEL WITH 7 AMP BREAKERS IN THE 332 POLE LOCATION DETA J/ CONTROLLER CABINET AND TERMINATE EACH CAMERA TO AN INDIVIDUAL CIRCUIT BREAKER. DETAIL"A" L / o � OINSTALL DETECTOR LOOPS AS SHOWN ON PLAN PER CALTRANS STD. 12" 3-SECTION VEHICLE HEAD ti 70 FURNISH AND INSTALL TRAFFIC SIGNAL MAST ARM MOUNTED OR POLE MOUNTED SIGN AS NOTED g NO SCALE PER CALTRANS STANDARD PLAN RS4 OR ES-7N (DETAIL "U"). NEW 2"C., 2 DLC FURNISH AND INSTALL OPTICOM MODEL 721 EMERGENCY VEHICLE PREEMPTION SENSOR ON VEHICLE HEAD AS SHOWN, PHASE AS NOTED, FINAL LOCATION TO BE DETERMINED BY ENGINEER R/W IN THE FIELD. CONTRACTOR SHALL ARRANGE TO HAVE A QUALIFIED SIGNAL TECHNICIAN OR — — �� REPRESENTATIVE FROM MANUFACTURER OF THE EVP UNIT PRESENT AT THE TIME OF EQUIPMENT-- _ TURN ON. — — — 04 7 R9-3 INSTALL TYPE 15-SB WITH.SLIP BASE AND 165 WATT LUMINAIRE PER CALTRANS _ — — — — // v BB FUT. BACK OF SIDEWALK NEW SC., 12 SMFO CABLE LLER STD. PLAN ES-6A AND ES-6F. — — — _ _-_- — — _ — — — — — —� / #6 2 PR. CURB FUT. CURB & GUTTER STREET(35 MPH) (INSTALL PULL BOX ®200' SPA NB'RAMP CING) - - - - - - - - - - �- PR. CURB T�K �"�•``E EX. EDP NEW SIGNS ON THIS SHEET R73-3(CA) R3-16 R61-7(CA O04) R9-3 R9-3 7 / \\ 6 06 DETAIL "A" NEW , EX. ST. LIGHT TO BE REMOVED i FUT. RAISED MEDIAN I 6 O I NEW 2"C., 2 DLC 6 (1 LOOP) NOUTURN 'ONLY EX. EDP 06 DETAIL "A" / -- �_ 5 (01+06) Tk R9-3 7 185' TO 6 (01+06) 3 6J4U N LIM T91' L NE 6J3U EM 29 LIMIT LINE 6J2U 11 2r� --- 26 a 7 R73-3(C ) - 1144 — — LEGEND - - - }- 01 - - + 185 TO — — -- — — 'SQ 27 EX. T. LIGHT TO BE REMOVED Jf VIDEO DETECTION ZONE 212U LIMIT LINE 213U — — — 67' T - 1Y��1 LIMIT LINE 214U o LIMIT LINE P VIDEO DETECTION CAMERA 5 (02) (1 LOOP) 6a - I (02) 6 02 _ o s __s-----------------=====c3----------- ---NEW 3C 12 SN1F0 CABLE ---------------- v m 214E — r PR. CURB R3-18 7. NEW -C., 2#10 a o 0 _ _ — — ---- --' PR. AC BERM GENERAL NOTES: __ _ — —_ _— TNT�_�LC — PR._ _ _ _ g 02 R9-3 PR. CURB 1. TRAFFIC SIGNAL WORK SHALL CONFORM TO THE PROVISIONS OF SECTION 86 OF THE 2015 ® — 04 �\ 04 �/ D 4 SCE HAND HOLE PR. EOP (T R9-3 7 I 2 3 FUT. CURB & GUTTER CALTRANS STANDARD SPECIFICATIONS. THE STANDARD PLANS: BOTH PUBLISHED BY — - �_ O 6 CALTRANS, APPLICABLE CITY OF LAKE ELSINORE'S SPECIAL REVISIONS. _ _ FUT. CURB & GUTTER 4 O # — — E 6 NEW 2"C., 3#6 FUT. BACK OF SIDEWALK 2. LOCATION OF ALL UNDERGROUND UTILITIES ARE APPROXIMATE. THE CONTRACTOR SHALL. T DETERMINE THE EXACT LOCATIONS AND VERIFY ALL CONDITION ON THE JOB SITE. HAND �_ _ _ — — — 1 - RECORD DRAWING DIG FOUNDATIONS UNTIL CLEAR OF OBSTRUCTIONS. PHONE UNDERGROUND SERVICE ALERT R/W R9-3 7 # y\ 5 THIS SET OF RECORD DRAWINGS HAS BEEN PREPARED (800) 227-2600. (� I s BASED ON VERIFICATION OF ACTUAL FIELD CONDITIONS. o 3. CONTRACTOR SHALL EXERCISE EXTREME CARE TO AVOID DAMAGING EXISTING UTILITIES. THEEACCEPTABLEER PER PHATGNBTRRAFFICEET umGNs R61-7(CA) 7 I ARE ACCEPTABLE PER APPLICABLE TRAFFIC DESIGN � 4. OBTAIN APPROVAL FOR EXACT EQUIPMENT LOCATIONS PRIOR TO FINAL PLACEMENT. J NDARDNLANS,E ETC.)AND N STANDARD PLANS,ETC.)AND ARE ACCEPTABLE IN MY / NEW 2"C., 2#10 AWG PROFESSIONAL OPINION AS A REGISTERED TRAFFIC 5. ALL VEHICLE INDICATIONS SHALL BE 12" WITH FULL TUNNEL VISORS. ALL SIGNAL HEADS EX. ST. LIGHT TO BE REMOVED— ENGINEER IN THE STATE OF CALIFORNIA. AND HARDWARE SHALL BE METAL. ALL RED, YELLOW, GREEN & PEDESTRIAN (HAND, 9 N FLASHING HAND, WALKING PED) INDICATIONS SHALL BE LED. I _ STA 371+80 N e a 6..EXACT POLE LOCATION SHALL BE DETERMINED BY ENGINEER IN THE FIELD AND SHALL BE uxaeaAREDstAA aaxsss POTHOLED PRIOR TO INSTALLATION. UNDERGROUND STRUCTURES I 7. ALL NEW CONDUITS SHALL BE TYPE 3, SCHEDULE 80. ALL UNDERGROUND UTILITIES OR STRUCTURES REPORTED BY THE OWNER OR OTHERS AND ON� G SB RAMP _ - -�- i THOSE SHOWN ON THE RECORDS EXAMINED ARE INDICATED WITH THEIR APPROXIMATE LOCATION iJ 8. ALL NEW I-A POLE FOUNDATIONS SHALL HAVE ANCHOR BOLTS WITH SLEEVE NUTS AS AND EXTENT. THE OWNER BE ACCEPTING THESE PLANS OR PROCEEDING WITH IMPROVEMENTS .o PER CALTRANS STD PLAN ES-76. PURSUANT THERETO AGRESS TO ASSUME LIABILITY AND TO HOLD UNDERSIGNED HARMLESS FOR NOTE: THIS PLAN IS ACCURATE FOR ELECTRICAL WORK ONLY 20 10 20 40 ANY DAMAGES RESULTING FROM THE EXISTENCE OF UNDERGOUND UTILITIES OR STRUCTURES NO 9. ALL NEW PULL BOXES SHALL BE NO. 5 EXCEPT AS SHOWN ON PLANS. REPORTED TO THE UNDERSIGNED: NOT INDICATED ON THE PUBLIC RECORDS EXAMINED: THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURE TO PROTECT UTITUES OR SCALE IN FEET o 10. ALL SALVAGED ELECTRICAL EQUIPMENT SHALL REMAIN THE PROPERTY OF THE STATE OF STRUCTURES SHOWN AND ANY OTHER UTILITIES OR STRUCTURES FOUND AT THE SITE. IT SHALL 1 inch = 20 ft. i CALIFORNIA AND SHALL BE DELIVERED TO THE DEPARTMENT YARD AT 175 CLUSTER pp BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE OWNERS OF THE UTILITIES OR CALTRANS PERMIT#08-15--6-MC-0720 STREET, SAN BERNARDINO, CA 92405. �1�1' STRUCTURES CONCERNED BEFORE STARTING WORK. CALTRANS PERMIT NO.08 15 6-MC-0720 MARK REVISIONS APPR. DATE m'ESE'PLANS mw BEEN REY/EWED FOR couPL4WCE wm 7NE PREPARED BY. SEA[ SI uAWRMAT,LAW At-ReeN�AN'BBC- Pff N CITY OF LAKE ELSINORE- .9VEET APAWPAY47E cavolpoNS OF DEVELOPMENT WPIOR C17Y AND STA7F �� Es oy� > PacuiaN narmNG >auNc D+aNBNc P,waNG ,3 LA#5 ANO A PERAOT AM BE ISSUED 11 20 19 �am wa e a sx m r ma a mos �a>ss ss 1 RECORD DRAWING UPDATES. Cy zvw�wexx wa�Okwumn eel oaaeaa Ode.Brirt]50,e„ie„O 9lbtf (04)025b115 JOHN TRACT 28214 OF 24 _ 2•17 i7 4�M_ o "°. c4/i595 SCALE, eENCN"i°RK fiNFF/C 5101 L INSTALLATION PLAN sNEE7s Li17E JOH P. KEATIN 11�2 19 9 .12C13311/20g C- ��� Iwo fog ELLM70V, 7JM,u Aat LAKE STREET GY�Y R.C.E. No. C43595 OF cA0 �7E, SEE SHEET NO. I FOR DE= ® /-75 59 RAMPS my ar LAKE i S1WO ��-Y�