Loading...
HomeMy WebLinkAboutDEL BRIENZA 28_15-00003086 Solar ;C I T4.- O LADE U LSIriOR-1 BUILDING & SAFETY DREAM EXTP E ME TM 130 South Main Street Lake Elsinore Ca. 92530 PERMIT PERMIT NO: 15-00003086 DATE: 11/03/15 JOB ADDRESS . . . . . 28 DEL BRIENZA DESCRIPTION OF WORK ELECTRICAL OWNER CONTRACTOR SHAVER, DANIEL D SOLARCITY CORP. 0000280 DEL BRIENZA 3055 CLEARVIEW WAY LAKE ELSINORE CA 92530 SAN MATEO, CA 94402 650-638-1028 LIC EXP 0/00/00 A. P.# ° . . . . 363-411-008 0 SQUARE FOOTAGE 0 OCCUPANCY . . . GARAGE SQ FT 0 CONSTRUCTION . . FIRE SPRNKLR VALUATION . . . 17, 000 ZONE . . . . . . NA BUILDING PERMIT QTY UNIT CHG ITEM CHARGE BASE FEE 63 . 00 15 . 00 X 12 . 5000 VALUATION 187 . 50 ELECTRICAL PERMIT QTY UNIT CHG ITEM CHARGE BASE FEE 30 . 00 1 . 00 X 16 . 2500 MISC. WHERE NO OTHER FEE 16 . 25 FEE SUMMARY CHARGES PAID DUE PERMIT FEES BUILDING PERMIT 250 . 50 . 00 250 . 50 ELECTRICAL PERMIT 46 . 25 . 00 46 . 25 OTHER FEES - I --I r• 1 ,-1 -„ 1.- w G; 11 —A 0 --I ::, ,-I PROF.DEV. FEE 2 TRADES 10 . 00 R 0 02 n I ,t: 1� 1,11 M:• —1 PLAN RETENTION FEE 2 . 07 b0'7 H I ^' 2 . O��J':� ' If °° °" — m• I a 0J ! II ° 2 SEISMIC GROUP R . 21 (?�' =;' 2 . "' � ii —I m • Q '.� GREEN BUILDING FEE 1 1 . 00 . 00 ; ;; r� . Q'OG.! =� ii —' T PLAN CHECK FEES 187 . 88 . b 0 r- I! ---1 _ `••' '�§7 . $r: u m = 1 m I I a• :a? r� ° G n !1 � r-�• cam. _! m TOTAL 499 . 91 . Q 0 r;_ 9'.9 . 9! SPECIAL NOTES & CONDITIONS ; . ; C-A C:a ii C "a fn ROOF MOUNT SOLAR 31 PANELS 2 INVERTERS 8 . 215 KW M I I II Al I I ti'�•• II I I u1 II ITS '� I I Q'•. 11 r� I P:� h:� I � 11 a• _� C! I 1:4 G:.I I 11 c� i r•:� r•:� I n City of Lake Elsinore ( Please read and initial Building Safety Division ` I am Licensed under the provisions of Business and professional Code Section 7000 et seq.and my license is in full force. Post in conspicuous place 2.I,as owner of the property,or my employees w/wages as their sole compensation will do the work on the job and the structure is not intended or offered for sale. 3.I,as owner of the property,am exclusively contracting with licensed contractors to construct the You must furnish PERMIT NUMBER and the �, project. JOB ADDRESS for each respective inspection: i'r4 I have a certificate of consent to selfinsure or a certificate of Workers Compensation Insurance Approved plans must be on job or a certified copy thereof at all times: 5.I shall not employ any person in any manner so as to became subject to Workers Compensation Laws in the performance of the work for which this permit is issued. Note:If you should become subject to Workers Compensation after making this certification, Code Approvals Date Inspector you must forthwith comply with such provisions or this permit shall be deemed revoked. ELO1 Temporary Electric Service PLO 1 Soil Pipe Underground EL02 Electric Conduit Underground BPO1 1 Footings BP02 Steel Reinforcement BP03 Grout BP04 Slab Grade PLO 1 Underground Water Pipe SSO1 lRough Septic System SWO1 On Site Sewer BP05 Floor Joists BP06 Floor Sheathing BP07 Roof Framing BPO8 Roof Sheathing BP09 Shear Wall&Pre-Lath ~ PL03 Rough Plumbing EL03 Rough Electric Conduit Q EL04 Rough Electric Wiring EL05 lRough Electric/ T-Bar MEN Rough Mechanical ME02 Ducts,Ventilating PL04 Rough Gas Pipe/Test PL02 Roof Drains BP l O Framing&Flashing BP 12 Insulation BPI Drywall Nailing BPI 1 Lathing&Siding _ PL99 *Final Plumbing EL99 *Final Electrical ME99' *Final Mechanical _ BP99'*Final Building "Final Signatures are Certificate of Occupancy for Single Family Residence -Code Pool&Spa Approvals Date Inspector OTHER DIVISION RELEASES .SPO 1 Electric Conduit UG Department Approval required prior to the SP02 UG Gas Piping building being released by the City SP03 Pool Steel Rein./Forms Date Inspector SP04 Pool PImb.lPressure Test Fire SP05 Pre-Gunite Approval EVMWD SP06 Rough Pool Electric _ Finance SP07 Pool Fence/Gates/Alarms fi Engineering SP08 Pre-Plaster Approval TliMF SP99 Final Pool/Spa Planning'Landscape CITY OF LAKE ELSINORE BUILDING AND SAFETY DIVISION Date: 12� NOTICE ❑ Stop Work LzCorrect Work Job Address y� Q I Permit Number �._ ec� I I Division Inspector CtITY,OF LADE �'LS I 1`�OI�E D REAM EXT RE M E TM 130 South Main Street APPLICATION FOR APPLIC ' BUILDING PERMIT AP LIGATION ECEIVE , DATE AP# BY VALUATION CALCULATIONS BUILDING ADDRESS pp 1st FLOOR SF I7EL_ ICI'' TRACT BLOCKIPAGE LOT/PARCEL 2nd FLOOR SF NAME 3rd FLOOR SF O S ka vt r bA i, W MAILING GARAGE SF N ADDRESS Same E CITY STATE/ZIP STORAGE SF R Lake Elsinore CA/1i2S 2 I hereby affirm that I am licensed under provisions of chapter 9(commencing DECK&BALCONIES SF with section 7000)of division 3 of the business and professions code,and C my license is in full force and effect. OTHER: SF O LICENSE# 88104/B C10 C46 CITY BUSINESS N AND CLASS TAX# T NAME VALUATION: $17,000 R SolarCity A MAILING C ADDRESS 3055 Clearview Way FEES T CITY AT Z P PHONE O San Mateo EAV�402 650.638.1028 BUILDING PERMIT R CONTRACTOR'S SIGNATURE U—A i E 2A' PLAN CHECK NAMELICENSE# A PLAN REVIEW R MAILING C ADDRESS SEISMIC H CITY STATE/ZIP PHONE PLAN RETENTION ❑NEW OCC GRP./ CONST. ❑ADDITION DIVISION: TYPE: ❑ALTERATION NUMBER OF NUMBER OF []OTHER STORIES: BEDROOMS: _ ❑SINGLE FAMILY ZONE: ❑APARTMENTS VI certify that I have read this application and state that the ❑CONDOMINIUM HAZARD YES above information is correct.I agree to comply with all city []TOWN HOMES AREA,-, , XOfr, and county ordinances and state laws relating to building ❑COMMERCIAL SPRIN Ek § L, , ,�, �. 1 5`," D I1 ii n I = ,-, --I construction,and hereby authorize representatives of this ❑INDUSTRIAL REQUfk-E6?m ,—, , �• i>kO=, r_� 11 .1 HERa. city to enter upon the above-mentioned property for insp- ❑REPAIR Dfi: w'., t� n r-, - -V -n tion purposes. ❑DEMOLISH �PROP(5SEboEt�WB PRESENT'USE OF " '_ II a! 0 r' t-jJOB DESCRIPTION _ _rn= 0 -j ,-a II -� 4 440 ITI T Residential roof mour t r- C ,' C' n a f,rl' {i i Signa a of Applicant or Agent Date 31 Panels -�I i'" s if ~` T 11 if ,_, o Inverters) r ,_, c„ c,:, n ,z r•._, m Agent for contractor ❑ owner ,Z 1 S kW I , m I CQ -, Agents Name Arwen Lott ' ' '=' u x r n Agents Address 41568 Eastman Dr c, 11 Murrieta, CA 92562 858.245.2080 - - if vaw v.y ...vw .,�+ 1 l•7••. 171 . I II -n ,�••. I 4 I II M. 0 1 4G 4 1 I I Version#52.6-TBD ;l;SolarCit WS y October 26, 2015 RE: CERTIFICATION LETTER Project/Job #9258598 Project Address: Shaver Residence n 28 Del Brienza Lake Elsinore, CA 92532 Q eyi�o Design Criteria: 5077 m -Applicable Codes = 2013 CBC,ASCE 7-10, and 2012 NDS Ex - Risk Category = II -Wind Speed = 110 mph, Exposure Category C -Ground/Roof Snow Load = 0 psf s + CML - MPl&MP2: Roof DL = 14 psf, Roof LL= 18.5 psfOFCALI Per Section 1613.1,W-(PV)/W-(exist roof) = 4%, Increase Seismic Shear Load < 10%, > [OK] To Whom It May Concern, A jobsite survey of the existing framing system of the address indicated above was performed by a site survey team from SolarCity. Structural evaluation was based on site observations and the design criteria listed above. Based on this evaluation, I certify that the existing structure directly supporting the PV system is adequate to withstand all loading indicated in the design criteria above based on the requirements of the applicable existing building and/or new building provisions adopted/referenced above. This review relies on the roof's structural system having been originally designed and constructed in accordance with the building code requirements and having been maintained to be in good condition. Additionally, I certify that the PV module assembly including all standoffs supporting it have been reviewed to be in accordance with the manufacturer's specifications and to meet and/or exceed all requirements set forth by the ASCE 7 standards for loading. The PV assembly hardware specifications are contained in the plans submitted for approval. Additionally a summary of the structural review is provided in the results summary tables on the following page. James H. Childs, P.E. Professional Engineer T: 888.765.2489 x58390 email: jchildsl@solarcity.com 3055 Clearview Way San Mateo,CA 94402 T(650)638-1028 (888)SOL-CITY F(650)638-1029 solarcity.com r Version#52.6-TBD SolarCit WS Y HARDWARE DESIGN AND STRUCTURAL ANALYSIS RESULTS SUMMARY TABLES Landscape Hardware-Landscape Modules'Standoff Specifications Hardware X-X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR MP1&MP2 72" 24" 52" 24" Not-Staggered 59.4% Portrait Hardware- Portrait Modules'Standoff Specifications Hardware X-X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR MP1&MP2 48" 20" 52" 24" Not-Staggered 39.6% Structure Mounting Plane Framing Qualification Results Type Spacing Pitch Member Evaluation Results MP1&MP2 Pre-Fab Truss @ 24 in.O.C. 240 Member Impact Check OK Refer to the submitted drawings for details of information collected during a site survey. All member analysis and/or evaluation is based on framing information gathered on site.The existing gravity and lateral load carrying members were evaluated in accordance with the IBC and the IEBC. 3055 Clearview Way San Mateo,CA 94402 T(650)638-1028 (888)SOS-CITY v(650)638-1029 solarcity.com SEISMIC CONSIDERATIONS Seismic Design Criteria (per USGS Seismic Desiqn Code ASCE 7-10 Latitude 33.6822 Lonqitude -117.2889 SRA at Short Period Ss 1.558 USGS SRA at is Period Sl 0.600 USGS Soil Site Class D IBC 1613.5.2 Seismic Design Category SDC D USGS Seismic Check Required(Ss> Yes IBC 1613.1 0.4cl &SDC>_ D)? ALTERATION LATERAL DESIGN 10% EXCEPTION CHECK Weight of Proposed PV System --- — --------------------------- Area Dead Load Weight — ------------- ------------ PV System Weight 549 sf 3 psf 1,647 Ibs Total Weight of PV System W(PV) 1,647 Ibs Weight of Roof on Existing Building Sum Area of MPs with PV 1684 sf Portion of Roof Weight Area Dead Load Weight Roof 1,684 sf 14.0 psf 23 571 Ibs Ceiling 1,684 sf 5.0 psf 8,418 Ibs Interior Walls (Top Half) 657 sf 5.0 psf 3,283 Ibs Exterior Walls(Top Half _ 657 sf 8.5 psf 5 580 Ibs Net Weight of Roof Under PV W(exist) 40,851 Ibs Check% Increase of Roof Wei ht / Seismic Shear Load Increase of DCR of Lateral 4.0% Force ResistingSystem W�Pv��Wye 15`t Increase Seismic Shear Load < 10% -> [OK] IBC Sect.3404.4 Note: Seismic base shear is directly proportional to roof weight. STRUCTURE ANALYSIS - LOADING SUMMARY AND MEMBER CHECK - MP1 & MP2 Member Properties Summary MP1 &MP2 Horizontal Member Spans Rafter Pro erties Overhang 2.16 ft Actual W 1.50" Roof System Pro erties San 1 6.83 ft Actual D 3.50" Number of Spans w/o Overhang) 3 San 2 5.95 ft Nominal Yes Roofing Material Flat Tile Roof San 3 5.56 ft A 5.25 in.A2 Re-Roof No Span 4 S. 3.06 in.A3 Plywood Sheathing Yes San 5 I 5.36 in.A4 Board Sheathing None Total Rake Span 22.44 ft TL Defl'n Limit 120 Vaulted Ceiling No PV 1 Start 2.67 ft Wood Species DF Ceiling Finish 1/2"Gypsum Board PV 1 End 17.92 ft Wood Grade #2 Rafter Slope 240 PV 2 Start Fb 900 psi Rafter Spacing 24"O.C. PV 2 End F„ 180 psi Top Lat Bracing Full PV 3 Start E 1600000 psi Bot Lat Bracing At Supports PV 3 End Emin 580000 psi Member Loading Summary Roof Pitch 6 12 Initial Pitch Adjust Non-PV Areas PV Areas Roof Dead Load DL 14.0 psf x 1.09 15.3 psf 15.3 psf PV Dead Load PV-DL 9.0 Psf x 1.09 9.9 sf Roof Live Load RLL 20.0 psf x 0.93 18.5 psf Live/Snow Load LL SL''2 Total Load(Governing LC I TL 1 1 15.3 psf 25.2 psf Notes: 1. ps=Cs*pf; Cs-roof,Cs-pv per ASCE 7[Figure 7-2] 2. pf=0.7(Ce)(C0(IS)p9; Ce=0.9,Ct=1.1, IS=1.0 Member Design Summary(per NDS Governing Load Comb CD CL + CL - CF Cr D 0.9 1.00 0.96 1.5 1.15 mber Analysis Results Summary Governing Analysis Pre-PV Demand Post-PV Demand Net Impact Result Gravity Loading Check -1056 psi -797 psi 0.75 Pass a CALCULATION OF DESIGN WIND LOADS - MP1 & MP2 Mounting Plane Information Roofing Material Flat Tile Roof PV System Type SolarCity SleekMountTM Spanning Vents No Standoff Attachment Hardware Mighty Hook HDG FT Roof Slope 240 Rafter Spacing 24" O.C. Framing Type/ Direction Y-Y Rafters Purlin Spacing X-X Purlins Only NA Tile Reveal Tile Roofs Only 13" Tile Attachment System Tile Roofs Only SM Span ,Standing Seam/Trap Seam/Trap Spacing SM Seam Only NA Wind Design Criteria Wind Design Code ASCE 7-10 Wind Design Method Partially/Fully Enclosed Method Basic Wind Speed V 110 mph Fig. 26.5-1A Exposure Category C Section 26.7 Roof Style Gable/Hip Roof Fig.30.4-2A/B/C-5A/B Mean Roof Height h 25 ft Section 26.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ 0.95 Table 30.3-1 Topographic Factor K, 1.00 Section 26.8 Wind Directionality Factor Kd 0.85 Section 26.6-1 Importance Factor I NA Velocity Pressure qh qh = 0.00256(Kz)(Kzt)(Kd)(V^2) Equation 30.3-1 24.9 psf Wind Pressure Ext. Pressure Coefficient U GC -0.88 Fig.30.4-2A/B/C-5A/B Ext. Pressure Coefficient Down GC Down 0.45 Fig.30.4-2A/B/C-5A/B Design Wind Pressure p p = qh (GCp) Equation 30.4-1 Wind Pressure U -21.8 psf Wind Pressure Down 16.0 psf ALLOWABLE STANDOFF SPACINGS X-Direction Y-Direction Max Allowable Standoff Spacing Landscape 72" 52" Max Allowable Cantilever Landscape 24" 24" Standoff Configuration Landscape Not-Staggered Max Standoff Tributary Area Trib 26 sf PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff T-actual -297 Ibs Uplift Capacity of Standoff T-allow 500 Ibs Standoff Demand/Capacity DCR 59.4% X-Direction Y-Direction Max Allowable Standoff Spacing Portrait 48" 52" Max Allowable Cantilever Portrait 20" j 24" Standoff Configuration Portrait Not-Staggered Max Standoff Tributary Area Trib 17 sf PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff T-actual -198 Ibs Uplift Capacity of Standoff T-allow 500 Ibs Standoff Demand/Capacity DCR 39.6% ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID—INTERTIED VIA A ALL EXPOSED CONDUIT WILL BE PAINTED TO AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. MATCH HOUSE. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. CONIC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING ALL LABELS WILL BE MADE FROM REFLECTIVE DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN MATERIAL. EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING SMOKE AND CARBON MONOXIDE DETECTORS TO BE EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, INSTALLED PER CRC R314 AND R315. FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED HAZARDS PER ART. 690.17. A LADDER SHALL BE SET UP AND READY FOR THE _ GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE INSPECTION. I GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY t'�K E E L.S I 1 V 0 C HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL DIVISION Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC i LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). {'j �. MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE - -- BY THE PL PROPERTYRLINE MANUFACTUROERAUSING ULPRO�LIISTDED GROUNDING 4 OV E Q POI POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT PV1 COVER SHEET 3R NEMA 3R, RAINTIGHT � PV2 SITE PLAN PV3 STRUCTURAL VIEWS PV4 UPLIFT CALCULATIONS ' : ►� PV5 THREE LINE DIAGRAM LICENSE GENERAL NOTES a Cutsheets Attached CA # 888104 1. ALL WORK TO BE DONE TO THE 2013 C-10 CALIFORNIA BUILDING CODE AND THE 2013 - CALIFORNIA RESIDENTIAL CODE. Ben Liu 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2011 NATIONAL ELECTRIC CODE AS AMENDED BY r' THE 2013 CALIFORNIA ELECTRIC CODE. MODULE GROUNDING METHOD: ZEP SOLAR • AHJ: Lake Elsinore r REV BY DATE COMMENTS REV A NAME DATE COMMENTS i I * * • a UTILITY: Southern California Edison IN role J B-9 2 5 8 5 9 8 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER: CONTAINED SHALL NOT BE USED FOR THE SHAVER, DAN SHAVER RESIDENCE Dhoirya Parikh �:, BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: � � ,So�arCity. NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook 28 DEL BRIENZA 8.215 KW PV ARRAY PART OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: LAKE ELSINORE, CA 92532 TMK OWNER: 3055 Clearview Way THE SALE AND USE OF THE RESPECTIVE 31 # KYOCERA KU2656ZPA * San Mateo, CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN RTER: � PAGE NAME: SHEET: REV DATE T:(650)638-1028 F:(650)638-1029 [Multiple NVEPERMISSION OF SOLARCITY INC. Inverters 7143131186 COVER SHEET PV 1 10/25/2015 (888)—SOL-CITY(765-2489)www.eolarcity.=n Ben Liu PITCH: 24 ARRAY PITCH:24 �- o MPi AZIMUTH:240 ARRAY AZIMUTH: 240 B U MATERIAL: Flat Cement Tile STORY: 2 Stories PITCH: 24 ARRAY PITCH:24 MP2 AZIMUTH:60 ARRAY AZIMUTH:60 MATERIAL: Flat Cement T'e TORY: 2 Stories I• I I 1 n ock9d G%Te-if 1 I y�� �1 0 0 0 u� No 05077 m I I "P' � B 1 0 0 o CmL o 0 _ _ _ _ _ _ _ _ J C _ Zd W 3' FSB o LC N - - - - - - - - - MPi LEGEND Oo ° ° (E) UTILITY METER & WARNING LABEL 1 o INVERTER W/ INTEGRATED DC DISCO L n ° ° & WARNING LABELS �I n MI T DC DISCONNECT & WARNING LABELS I � ° O° Locked Gated © AC DISCONNECT & WARNING LABELS 0 o O DC JUNCTION/COMBINER BOX & LABELS Q DISTRIBUTION PANEL & LABELS AC A LC LOAD CENTER & WARNING LABELS ODEDICATED PV SYSTEM METER OO STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR --- CONDUIT RUN ON INTERIOR — GATE/FENCE O HEAT PRODUCING VENTS ARE RED r, 1� `I INTERIOR EQUIPMENT IS DASHED L_"J �. TOTAL ARRAY AREA (SF): 560 SITE PLAN Scale: 1/8" = i' � TOTAL ROOF AREA (SF): 2592 TOTAL ARRAY AREA IS a 21.62 0 i 8' 16' 3 PERCENT OF TOTAL ROOF AREA CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: PREMISE OWNER: DESCRIPTION: DESIGN: JB-9258598 00 SHAVER, DAN SHAVER RESIDENCE Dhairya Parikh ,SO�afC�t . CONTAINED SHALL NOT BE USED FOR THE ���•?� • BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: .,,z NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook 28 DEL BRIENZA 8.215 KW PV ARRAY ► ., PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES. LAKE ELSINORE CA 92532 3055 Clearview Way THE SALE AND USE OF THE RESPECTIVE (31) KYOCERA # KU2656ZPA PAGE NAME SHEET: REV DAIS San Mateo, CA 94402 PERMISSION CITY S LARCITY INC. THE WRITTEN INVERTER:ult 7143131186 PV 2 10 25 2015 (888)-sa�CITY(765 2489)w :�'ciy�, Multiple Inverters SITE PLAN / / ' t.Ben L.0 ,(TSS (E) 2 S1 —2" —9" —11" 5-6" (E) LBW SIDE VIEW OF MP2 NTS MP2 X-SPACING X-CANTILEVER Y SPACING Y-CANTILEVER NOTES CIO LANDSCAPE 72" 24" 52" 24" No 050775 m PORTRAIT 48" 20" 52" 24" CZ Exp. � TOP CHORD 2X4 @ 24"OC ROOF AZI 60 PITCH 24 STORIES:2 ARRAY AZI 60 PITCH 24 � ` ' BOT CHORD 2X4 @24"OC Flat Cement Tile Ca�� 10A6X5 INSTALLATION ORDER (E) 2x4 ZEP SPANNER BAR LOCATE RAFTER, MARK RAFTER (6) LOCATION, AND REMOVE TILE. (1) PLACE STANDOFF BASE & DRILL PILOT HOLES AT THE RAFTER S1 " DIA BOLT & NUT (1) (2) (7) (3) 2) CLEAN PAPER AROUND PILOT ZEP SPANNER HOLE. BAR CLAMP 3) ADJUST STANDOFF TO BATTEN HEIGHT. STANDOFF —2" '-10" 5'-11" 5'-7° (E) TILE SEAL PILOT HOLES AND BOTTOM (f (4)OF STANDOFF WITH POLYURETHANE (E) LBW (E) ROOF DECKING (5� (4) SEALANT. 5/16" DIA STAINLESS 5) LAG STANDOFF INTO RAFTER. SIDE VIEW OF MP1 NTS STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES (�) (2-1/2' EMBED, MIN) 6) NOTCH TILE WEATHERING TO FIT MPI X-SPACING I X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES (E) RAFTER AROUND STANDOFF. LANDSCAPE 7r' 24" sr� 24" 1 STANDOFF PORTRAIT 48" 20" 52" 24" i Scale: 1 1/2"= 1' 7) REINSTALL TILE. TOP CHORD 2X4 @ 24"OC ROOF AZI 240 PITCH 24 STORIES: 2 ARRAY AZI 240 PITCH 24 BOT CHORD 2X4 @24"OC Flat Cement Tile PREMISE OWNER: DESCRIPTION: DESIGN- CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER J B-9258598 00 CONTAINED SHALL NOT BE USED FOR THE SHAVER, DAN SHAVER RESIDENCE Dhairya Parikh �� a SolarCity. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEMi NOR SHALL IT BE DISCLOSED IN WHOLE OR IN 28 DEL BRIENZA l PART TO OTHERS OUTSIDE THE RECIPIENT'S ZEP Mighty Hook 8.215 KW PV ARRAY �r ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: LAKE ELSINORE, CA 92532 THE SALE AND USE OF THE RESPECTIVE (31) KYOCERA # KU2656ZPA 3055 Clearview Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEEC REV DATE San Mateo,CA 94402 PERMISSION OF SOLARCITY INC. Multiple Inverters 7143131186 STRUCTURAL VIEWS PV 3 10/25/2015 (BBB)SO CITY(7658-24F89)w,.solarcciitycom GROUND SPECS, MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND N 8 GEC TO N GROUND ROD Panel Number:MB204OP20OSD Inv 1: DC Ungrounded CA # 888104 ( ) # ( ) INV 1—(1)ABB#Pm-3.6—ouTD—S—US—z—A LqBEL: A —(31)KYOCERA # KU2656ZPA AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:222011-804055 Inv 2: DC Ungrounded FCI Inverter, Zigbee 360OW, 240V, 96Y. PV Module; 265W, 238.1W PTC, 40MM, Blk Frm, H4, ZEP, 1000V, Blk Cell,io Backbor C-10 Underground Service Entrance INV 2—(1)FCl PVT-3.0—Oee 300US—Z—A B ( gt LQ FCI Inverter, Zigbee 3000W, 240V, b Voc: 38.3 Vpmax: 31 ELiJr'1i _ INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER 1,: �E 200A MAIN SERVICE PANEL E)'20OA/2P MAIN CIRCUIT BREAKER ADJUST MIN. ACTIVATION VOLTAGES! SolarCity CUTLER—HAMMER BRYANT Inverter 1 IND ( 6 ❑A 1 200A/2P Disconnect 11 9 ABB Dc+ Vstart= 200V N) 125A Load Center PVT-3.6—OUTD—S—US—Z—A I I DC- I MP 1: 1x8 (E) LOADS B C 20A/2P ------------ — ------- — — EGc-----------------j L1 zaav r--------- L2 OC+ N DG I 5 2 Vstart= 200V 40A/2P _--- GND _ ----___--- EGC/ DC+ V - --------------- --- --- m JA �l r o r GEC .l N DG MP 1: 1x8 c� I EGC B I I Z I GND ADJUST" MIN. ACTIVATION VOLTAGES! (1)Conduit Kit; 3/4" EMT " Inverter 2 IND s +IGC EGC/GEC _ I 10 ABB Vstart= 200V PVT-3.0—OUTD—S—US—Z—A MP 2: 1x7 20A/2P --- ------------ — --------L1 zaov r------ -------------tpj--- GEC -.- I L2 DC+ TO 120/240V I I N DC- I 7 4 Vstart = 200V SINGLE PHASE i _ EGa ___ Dc+ I-TDC,UTILITY SERVICE I _ GEC � G MP 2: ix8 EG - ------------------� I (1)Conduit Kit; 3/4"EMT CONNECT TO THE EXISTING GEC OR BY IRREVERSIBLE CRIMP TO EXISTING GROUND WIRE. Voc* = MAX VOC AT MIN TEMP POI (1)CUTLER—HAMM�R#BR240 'PV BACKFEED BREAKER B (1)CUTLER—HAMMER #DG222URB A (1)SolarCityy 4 STRING JUNCTION BOX Breaker, 40A 2P, 2 Spaces Disconnect; 60A, 24OVac, Non—Fusible, NEMA 3R AC 2x2 STR GS, UNFUSED, GROUNDED DC —(1)Gro qd Ro# —(1)CUTLER—{1AMMER.#DG100NB 5r8 x 8, Copper Ground Neutral it; 60-100A, General Duty(DG) C (1)BRYANT#BR48L125RP Load Center, 125A, 120/24OV, NEMA 3R —(2)Breaker,H2OAE/2P. 2 Spaces � 1 AWG#8,THWN-2, Black 1 AWG#10, THWN-2, Black (1)AWG#10, THWN-2, Black Voc* =347.21 VDC Isc =9.26 ADC (2)AWG#10, PV Wire, 60OV, Black Voc* =347.21 VDC Isc =9.26 ADC Isf—(1)AWG#8, THWN-2,Red O LPL (1)AWG#10, THWN-2, Red O (1)AWG#10, THWN-2, Red Vmp =248 VDC Imp=8.55 ADC O�(1)AWG#10, Solid Bare Copper EGC Vmp 248 VDC Imp—8.55 ADC I (1)AWG#8,THWN-2, White NEUTRAL Vmp =240 VAC Imp=30.5 AAC (1)AWG#10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=16 AAC (1 AWG#10, THHN/THWN-2,,Green, EGC-... .. • . . . .. . . .. . . . . . . . . , ,,, . . . . . ... . .... .. .. .... ... . .. . ... . . .. .. . . .. .. . . .. . . . ......-,(1)AWG#8,,TN,WN-2,,Green ,• EGC/GEC, (1)Conduit.Kit;,3/4�. MT. ., . ,, . ,, , ,, • ,, . (1)AWG#B,,THwN-2,,Green ,, EGC/GEC, (1)Conduit,Kit;,3/4",EMT• ,_ . ,, , ,. . (1 AWG#10, THWN-2, Black Voc* =347.21 VDC Isc =9.26 ADC (2)AWG#10, PV Wire,600V, Black Voc* =347.21 VDC Isc =9.26 ADC (1)AWG#10, THWN-2, Black © (1)AWG#10, THWN-2, Red Vmp =248 VDC Imp=8.55 ADC O , (1)AWG#10, Solid Bare Copper EGC Vmp 248 VDC Imp=8.55 ADC. ®�(1)AWG#10, THWN-2, Red . .... . , (1)AN#10, TIiHN/THWN-2,,GYeen EGC .... ... .. ........ . . .. .. .. . .. . (1)AWG#10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=14.5 AAC (1)AWG#10, THIMJ-2, Black Voc* 347.21 VDC Isc =9.26 ADC (2 AWG#10 PV Wire,60OV, Black Voc* =303.81 VDC Isc =9.26 ADC. (1)AWG#8,,TH.WN-2,,Green , , EGC/GEC,—(1)Cond k Kit;.3/47.EMT, . . . , ,, , .. O (1)AWG 110, THWN-2, Red Vmp =248 VDC Imp=8.55 ADC O (1)AWG#10,Solid Bare Copper EGC' Vmp =217 VDC Imp=8.55 ADC 0 AWG#10, TIiHN/THWN-2,,Green EGC , , , . . .. — (1 AWG 110, THWN-2, Black Voc* 303.81 VDC Isc =9.26 ADC (2)AWG#10,PV Wire, 600V, Black Voc* 347.21 VDC Isc =9.26 ADC ® (1)AWG 110, THWN-2, Red Vmp =217 VDC Imp=8.55 ADC ® (T)AWG#10,Solid Bare Copper EGC Vmp =248 VDC Imp=8.55 ADC J B-9 2 5 8 5 9 8 00 PREMISE OWNER: DESCRIPnON: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: \!a SO�a�C�t CONTAINED SHALL NOT BE USED FOR THE _ SHAVER, DAN SHAVER RESIDENCE Dhairya Parikh BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: ��, NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook 28 DEL BRIENZA 8.215 KW PV ARRAY y. PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: LAKE ELSINORE, CA 92532 ORGANIZATION, EXCEPT IN CONNECTION WITH .3 5 Clearview Way THE SALE AND USE OF THE RESPECTIVE (31) KYOCERA # KU2656ZPA PAGE NAME SHEET: REV: DATE San Mateo, CA 94402 PERRSOLMSSIONCITY EOFISOELARCITY INC.NT, WITHOUT THE WRITTEN '"„�,�R, 7143131186 THREE LINE DIAGRAM PV 5 10/25/2015 (88)(SOL)CITYY(765-2489)www da°lycom Multiple Inverters CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: - Address: 28 Del Brienza r— INVERTER AND AC DC DISCONNECT DISCONNECT I I I I . I I I r J r—Tl I I I I I I I I I I I I I I I I I I � INVERTER AND UTILITY DC DISCONNECT SERVICE r---------------------------I SOLAR- PHOTOVOLTAIC ARRAYS) J PHOTOVOLTAIC BACK-FED aRCUIT BREAKER IN MAIN ELECTRICAL PANEL IS AN A/C DISCONNECT PER NEC 690.17 OPERATING VOLTAGE = 240V JB-9258598-00 CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: PREMISE OWNER: DESCRIPTION: DESIGN: JB-9258598 00 = SolarCity. CONTAINED SHALL NOT BE USED FOR THE SHAVER DAN SHAVER RESIDENCE Dhairya Parikh �.��?� BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �.��c NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty HOOT( 28 DEL BRIENZA 8..215 KW PV ARRAY �r PART TO OTHERS OUTSIDE THE RECIPIENTS NODDIES LAKE ELSINORE CA 92532 ORGANIZATION, EXCEPT IN CONNECTION WITH , 3055 Cleorview Way THE SALE AND USE OF THE RESPECTIVE (31) KYOCERA # KU2656ZPA SOLARCITY EQUIPMENT, W1THOUT THE WRITTEN INVERTER: PAGE NAME SHEET: REV DATE E(650)Son Mateo, CA 9440638-1029 PERMISSION OF SOLARCITY INC. Multiple Inverters 7143131186 SITE PLAN PLACARD PV 6 10/25/2015 ' (BBB)—SOL—CITY(765-2489)www.solarcityccm WARNING:PHOTOVOLTAIC POWER SOURCE Label Location: Label Location: Label • • PV SYSTEM WARNING ' Per Code: DISCONNECT FOR ••- CRC R331.2UTILITY OPERATION ELECTRIC SHOCK HAZARD CEC • THE DC CONDUCTORS OF THIS •- PHOTOVOLTAIC SYSTEM ARE TO BE USED WHEN PHOTOVOLTAIC DC MAY BEOENDERGIZED RTEUNGROUNDED • IS DISCONNECTCode: CEC .•0 .14.C.2 Label Location: WARNING ' Per ..- ELECTRIC SHOCK HAZARD '•' • - • DO NOT TOUCH TERMINALS MAXIMUM POWER TERMINALS ON BOTH LINE AND POINT CURRENT(Imp)_qPer Code:CEC LOAD SIDES MAY BE ENERGIZED MAXIMUM POWER-_ IN THE OPEN POSITION POINT VOLTAGE(Vmp) �� 690.53 MAXIMUM SYSTEM_\J VOLTAGE(Voc) SHORT-CIRCUIT_q CURRENT(Isc) Label Location: Per WARNING ..- INVERTER OUTPUT CONNECTION Label • DO NOT RELOCATE WARNING Per THIS OVERCURRENT DEVICE •.- ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALSCEC 690.17 TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION Label • • DC VOLTAGE IS PHOTOVOLTAIC POINT OF • Per ALWAYS PRESENT tiNHEN INTERCONNECTION •d_ CEC SOLAR MODULES ARE WARNING' ELECTRIC SHOCK EXPOSED TO SUNLIGHT HAZARD. DO NOT TOUCH •• CEC 690.17 TERMINALS.TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION. FOR SERVICE Label Location: DE ENERGIZE BOTH SOURCE WARNING Per AND MAIN BREAKER. PV POWER SOURCE Code: CEC MAXIMUM AC A ELECTRIC SHOCK HAZARD •. OPERATING CURRENT IF A GROUND FAULT IS INDICATED NORMALLY GROUNDED MAXIMUM AC _ V CONDUCTORS MAY BE OPERATING VOLTAGE UNGROUNDED AND ENERGIZED Label • • Label Location: PHOTOVOLTAIC AC I) Per CAUTION ' • ' • PHOTOVOLTAIC SYSTEM Code: Disconnect DISCONNECTPer Code: CIRCUIT ISBACKFEDCEC690 •4 ' Conduit CEC •.014.C.2 (CB): Combiner :. Distribution Disconnect (IC): Interior Run Conduit Label Location: Label Location: (INV): Inverter With Integrated DC Disconnect MAXIMUM AC q P• CAUTION P• OPERATING CURRENT DUAL POWER SOURCE ••- Load .• - Code: MAXIMUM AC CEC •. SECOND SOURCE IS OPERATING VOLTAGE V PHOTOVOLTAIC SYSTEM '•1): Point of • • San Mateo,CA 94402 • • • . • • • i mmmi • • ' • RM I wM11#1111:0C Solar inverters Additional highlights: —••— •" — RS-485 communication interface (for connection to laptop or data logger). • / • . — Integrated Arc Fault Detection and M Interruption(-A Version). �II�IIIIl 3.OkW to / • i' i Technical data and types Type code PVI-3.0-OUTD-US PVI-3.6-OUTD-US PVI-3.8-OUTD-US PVI-4.2-OUTD-US Mt Mechanical specifications Nominal output power 3000W 360OW 3W0 380OW 420OW ................................................................................. ......... . .......... .................i ... ..i ....... { i.:...... i.... Maximum output power wattage 3000 3300 3300 3600 4000 4000 3300 4200' 4200' 4200 4600' 4600 W W W W W W W W W W W W .......................................................:.................:.......................................................'..........................._............._.............._........................................-........................................................ Rated grid AC voltage i 208V - 240V 277V 208V 240V 277V 208V 240V 277V 208V 240V 277V Input side(DC) Number of independent MPPT channels 2 2 .,.,,_„-.. 2 2 Maximum usable power for each channel 2000W 3060W 3000W wooW uin ........ ......... ......... ..... ...... ........ .. ......... ......... ......... ......... .._.................................................. Absolute maximum voltage(Vmax) 600V ............. ............. .... _......... ................ . Start-up voltage(Vstart) 200V(adj.120-350V) .... ..... .... ...... .... ... ..... ............. Full power MPPT voltage range 160-530V 120-530V 140 530V 140 530V .... ..... ........... ... .... .r. OperatingMPPT volta a range 0.7 x Vstart-580V(> 90V) Maximum current(Idcmax)-for both MPPT in `• 20A 32A 32A 32A parallel.. .._. ....._ __. ._ `:. Maximum usable current per channel 10A 16A 16A 16A Maximum short circuit current limit per channel 12 5A : 20 OA 20 OA 20 OA Number of wire landing terminals per channel 2 pairs �„N�.,..... Array wiring termination Terminal block,pressure clamp,AWG10-AWG4 Output side(AC) Grid connection type 10/ Split- 10/ 10/ Split- 10/ ! Split- 10/ 1� Split- 10/ 2W s 0/3W 2W 2W 0/3W ! 2W i 2W 0/3W i 2W i 2W 0/3W i 2W 1.83.........21.1........244_........183_......21.1._......._244_.........183_......._21.1_.......244_.........183_........211_.... 244_..... Adjustable voltage range(Vmin-Vmax)M 228V ` 264V 304V 228V 264V i 304V i 228V i 264V 1304V 228V 264V 1304V ............................................................................................................... ......................................................................................................................................................................................................................................... ..Grid.frej4angy.......................................................................-!_ ........................................................................................................ .......................................................................................................................... Adjustable._grid frequency range 57-60.5Hz Maximum current(h—) 14.5 f4.5 12 0....` 1 Y.2 1 6.0 1 B.b 16.6 16.0 f6.0 20.b 2b.5 20.0 Any a A a ns .. Ab s..i...Aaw..'_....Aww..i...!�ws........ as..€.... s ......!�ro.c..........�...... Power factor >0.995 .. ........ ...................... .................. Total harmonic distortion at rated power <2% ............... ............ ......-.,,... This family of single-phase string The high-speed MPPT offers real- Highlights: Grid wiring termination type Terminal block,Pressure clamp,AWG10-AWG4 inverters complements the typical time power tracking and improved — Single phase and split phase output gput protection devices .Reverse polarity protection Yes - number of rooftop solar panels energy harvesting. grid connection. Over-voltage protection type Vanstor,2for each channel enabling home-owners to get the most The flat efficiency curve ensures high — Wide input range for increased PV array ground fault detection Pre start-up Riso and Dynamic GFDI(requires floating arrays) efficient energy harvesting for the size efficiency at all output levels allowing stringing flexibility. Output protection devices of theproperty. a consistent and stable performance The high speed and precise MPPT Anti-islanding protection Meets UL 17avIEEE15a7 requirements .. p 9 P Over-voltage protection type. Varistor,-2(L L:/_L G) across the entire input voltage and algorithm offers real time power Maximum AC OCPD Rating 20A„ 20A,, � 15A,,,,, 25A,,,,, 20A_20A__ 20A__ 20A,_ 20A_i 25A , :25A • 25A This inverter offers a dual input output power range. tracking and improved energy Efficiency section that processes two strings The transformerless operation gives the harvesting. Maximum efficient 96.9% 97% 97% 97% Y ...... .... ... CEC efficiency � � - 96% with independent Multiple Power Point highest efficiency of up to 97.0%. — Outdoor NEMA 4X rated enclosure Operating performance Tracking(MPPT). The wide input voltage range makes for unrestricted use under any Night time consumption ! _ <0.6W__ This is especially useful for rooftop the inverter suitable to low power environmental conditions. stand-by consumption <sw Communication installations with two different installations with reduced string size. — Integrated DC disconnect switch User-interface 16 characters x 2 lines LCD display orientations from two sub-arrays This rugged outdoor inverter has been in compliance with international Remote 1.monitoring(1 xRS48 1.5 Incl.) VSN700 Data Logger(opt.) oriented in different directions.(For designed to be a completely sealed Standards(-S Version). Envwronme a , Ambient air operating temperature range 13 F to+140 F with derating above 122°F(50 C) example:East and West) unit able to withstand the harshest Ambient air storage temperature range . 40.F to+176 F(40°C„to+So°C) ........ .................. Relative humid 0 100%RH condensing The dual input sections with environmental conditions. Acoustic noise emission level <SO- (A) 1m g ......................................................... independent MPPT enable a more Maximum o eratin' akifutde without deratin ....................... 656o fI 200..m ................. P...........g........................................._..........g..........................._ _..........................._ ........................ (.............)........................................................................................._..... optimal energy harvesting condition. Power and productivity A a 1.Capability enabled at nominal AC voltage and with sufficient DC power available. for a better world'" 2 A88 Solar Inverters I Product flyer for PVI-3.0/3.6/3.8/4.2-TL-OUTD ® ,r, -i6olarClty ZepSolar Next-Level PV Mounting Technology ''I"SolarClty ZepSolar Next-Level PV Mounting Technology Components ZS Span for concrete tile roofs 1x 3x 4x Spanner Bar ZOPBrO01e lownN NO Part Nos. ► 850-1400-4x / 580-1399-3x � 850-1398-1x 6rorrd Zp s Bar ... -, SDarrrrClamV - T•l oa Aerap9dR 1� �- _ Splice Kit Spanner Clamp I Part No.850-1401 Part No.850-1194 Listed to UL 2703 Listed to UL 2703 CornrCap InoMock AdJrnW"MWty Hook dam �pMPgT� _ Description Isom PV mounting solution for concrete tile roofs i Works with all Zep Compatible Modules Auto bonding UL-listed hardware creates structural and electrical bond • Zep System has a UL 1703 Class"A"Fire Rating when installed using modules from any manufacturer certified as"Type 1"or"Type 2" Mighty Hook V2,HDG Interlock Cam Foot U� LISTED Specifications Part No.850-1461 Part No.850-1388 Part No.850-1413 Listed to UL 2703 Listed to UL 2703 Listed to UL 2703 • Designed for pitch roofs �S Installs in portrait and landscape orientations Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 • Wind tunnel report to ASCE 7 05 and 7 10 standards • Zep System grounding products are UL listed to UL 2703 and ETL listed to UL 467 4&4 • Zep System bonding products are UL listed to UL 2703 • Engineered for spans up to 72"and cantilevers up to 24" • Zep wire management products listed to UL 1565 for wire positioning devices • Attachment method UL listed to UL 2582 for Wind Driven Rain Ground Zep Array Skirt, Grip, End Caps DC Wire Clip Part No.850-1172 Part Nos.850-0113,850-1421, Part No.850-1448 ETL listed to UL 467 850-1460,850-1467 Listed to UL 1565 zepsolar.com zepsolar.com Listed to UL 1565 This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. Document#800-1730-001 Rev A Dale last exported:April 20,2015 2:14 PM Document#800-1730-001 Rev A Date last exported:April 20,2015 2:14 PM KU-60 1000V Series ELECTRICAL SPECIFICATIONS MODULE CHARACTERISTICS PJ Icy0CERa KU-60 100OV Z Series - • • - • • • Cells per module: 60(6x 10) 1000 ' Dimensions: 65.43in i38.98in i 1.57in KU265-6ZPA length/width/height (1662mm/990mm/40mm) Weight: 45.2lbs(20.5kg) CUTTING EDGE TECHNOLOGY - — — —— — P.. 265 w As a pioneer with four decades of experience in the v., 31.0 v PACKAGING SPECIFICATIONS development of photovoltaic systems, Kyocera drives the MEMO market as a leading provider of PV products.We IM ro 8.55 A Modules per pallet: 20 demonstrate our Kaizen philosophy,or commitment toNEEMEM V_ 38.3 V Pallets per53'container. 36 continuous improvement,by setting the industry standard Pallet box dimensions: 66in)40ini43in in the innovation of best-in-class solar energy equipment. IK 9.26 A length/width height (1675mm/1005mm)1055mm) MENEM Pt°le ae a +5/-0 % Pallet box weight: 1 O151bs(460kg) QUALITY BUILT IN Nominal Oper—atin—gCell Temperature Conditions(NOCT) •UV-stabilized,anodized aluminum frame in black NOCT=800 I.57- •Supported by major mounting structure manufacturers T., 45 °C 'n` PO7TE0 •Easily accessible grounding points on all four corners Pm,x 191 w �TM for fast installationMEMENE v z7.9 v •Proven junction box technology with 12 AWG PV wire o"tEc oR works with transformerless inverters MENEM ImR 6.85 A LABEL •Amphenol H4-UTX locking plug-in connectorsINEENE V. 35.1 V provide safe,quick connections7.149 A PROVEN RELIABILITY PTc 238.1 w •Kyocera modules confirmed by the Desert Knowledge Temperature Coefficients Australia Solar Centre to have the highest average ENEEMN output of any crystalline module Pm -0.45 %J°C 1.10"(28-) MENNEN •First module manufacturer in the world to pass long- v -0.48 %/°C term sequential testing performed by TOV Rheinland 1, 0.02 %/°C _ •Only module manufacturer to achieve the rank of 38.g8"(99Q•n) Performance Leader" in all six categories of GTM _ __ _ _- v_ -0.36 %i°c Research's 2014 PV Module Reliability Scorecard �6 h� 0.06 %/°c 0 CERTIFICATIONS Operating Temp -40 to+90 °c Grounding Hole Slotted Vaunting Hole 0.16-(4 0 0.35-0.47-(9mx 12em) •UL1103 Certified and Registered,UL Module Fire Performance:Type 2,CEC FRAME CROSS SECTION DIAGRAM •NEC 2008 Compliant,IEC 61215161730,and ISO 14001 Series Fuse Rating 15 A a';'' GOMPAT,4 Maximum DC System Voltage(UL) 100o V W' C uL US = �°E Hailstone Impact in(25mm)@ 51 mp(23mis) ae tx. �0 'Subject to simulator measurement uncertainty of+1-3%. QCOMPPS KYOCERA reserves the right to modify these specifications without notice. LONG/SHDRT SIDE WARNING:Read the instruction manual in ils entirety prior to handling,installing&operat- ing Kyocera solar mo&les. 040215 OUR VALUED PARTNER HIGH EFFICIENCY MULTICIRYSTAL PHOTOVOLTAIC M• • • KYOCERA Solar, :•I • 8 ••• • fax www.kyocerasolar.corn SolarCity Standard BOX 4J NOTICE OF COMPLETION AND AUTHORIZATION TO APPLY THE UL MARK The SolarCity Standard Box 4J is a •Manufactured to meet UL 1741 Standards. Sola12/21/2013 4-Stringunfused Junction Box.The box Alex Yang Corp •Non-Metallic,Corrosion Resistant NEMA 4X Enclosure. Alex Yang is highly configurable and adaptable 3055 Clearview Way using the(4)jumper blocks included in •Factory-Installed Cordgrip Enhances Installation Speed. San Mateo Ca 94402-3709,Us each box. A factory installed cordgrip •Break-Thru Skinned-Over Glands on Cordgrip Provide enhances Installer productivity. Weathertight Seal for All Configurations. Our Reference: E318537,Volume 1 Project Number 4786083586 • Easily Configurable Terminal Blocks Permit Adaptation Your Reference: A.Yang 10/7 Project Scope: Investigation of Photovoltaic(PV)System Combiner Box,model"SolarCity Standard Box 4C" to Site-Specific Stringing Needs. and Photovoltaic(PV)System Transition Box,model"SolarCity Standard Box 4J"to UL 1741 Standard. Dear Alex Yang: Technical Data / Specifications Congratulations! UL's investigation of your product(s)has been completed under the above Reference Number and the product was determined to comply with the applicable requirements This letter temporarily supplements the UL Follow-Up Services Procedure and serves as authorization to apply the UL Mark at authorized factories under UL's • Voltage Rating[VDC] :600V Follow-Up Service Program. To provide your manufacturer(s)with the intended authorization to use the UL Mark, you must send a copy of this notice to each manufacturing location currently authorized under E318537,Volume 1 • Maximum DC Current[A]:57A and including any special instructions as indicated in the addendum to this letter. © � Maximum Continuous Current[A]:42A Records in the Follow Up Services Procedure covering the product are now being prepared and will be sent in the • Maximum Voltage[VDC]:600V near future. Until then,this letter authorizes application of the UL Mark for 90 days from the date indicated above. • Wire Size Range[AWG]:#6 to#14 Additional requirements related to your responsibilities as the Applicant can be found in the document"Applicant responsibilities related to Early Authorizations"that can be found at the following web-site: • Enclosure Rating:NEMA 4X htto:Owww.ul.corrdEAResoonsibilities tt`r y y Operating Temperature Range C 40 to 50 An information and documentation provided to you involving UL Mark services are provided on behalf of UL LLC P 9 P 9 [� ]�- Y� P Y 9 • Typical Overall Dimensions(in]:8"x6"x4" (UL)or any authorized licensee of UL. We are excited you are now able to apply the UL Mark to your products and appreciate your business. Feel free to contact me or any of our Customer Service representatives if you have any questions. f Very truly yours, Reviewed by: Jon Adonay William R.Carney 408-754-6630 8471664-1088 Engineering Associate Lead Chief Engineer Director I Jon.Adonay@ul.com Wiilliam.R.Camey@ul.com NBKD9C5-90BA67 ��11Ii •= 24SOIaifi Y, October 2013 This is an electronically generated letter Signatures are not required for this document to be valid- Page 1 of 1