Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
05-240
CONDUCTOR SCHEDULE DETAIL "A" DETAIL "B" p O POLE SCHEDULE AWG CIRCUIT Q P UO POLE DATA SIGNAL H.P.S.V. LUM SIGNAL MOUNTING IPED PUSH BUTTON 'I`POLE LOCATION NON-ILLUMINATED SIGN 004,06 2 2 2 DETECTOR 02 05,06,06P 1 1 1 1 O (OPTICOM MODEL 711) G� \\ No TYPE HEIGHT MA MA WATTS VEH MA PED PHASE POLE QUAD A B MESSAGE (DBL FACE) RED '` 1 15 30' — 12' 250 SV-2—TB — — 6 S 12' 3' 12 9 02,04,05 2 2 2 w� 2 1A 10' — — — TV-2—T — SP-1—T — — 8' 8' CSC ®01,02'04 2 2 CJ \ 3 26-4-129 30' 40'0 15' 250 SV-2—TB2—MAS — — — AS SHOWN 5 Church Road ©01,02,06,06P 2 6 _ _ YELLOW '� 4 19-4-129 30' 25' 15'O 250 SV-3—TB -4 — AS SHOWN 5' Railroad Canyon Rd• y 5 26-4-129 30' 45'® 15' 250 —— 2—MAS SP-1—T — — 12' 3' Church Road TOTAL 2 4 1 3 3 9 0 14 MASTARM MOUNTING CLAMP 6 PPB POST 4'-2" — — — — — — 6 S 15' 3' t 06 PPB 1 1 1 GREEN O O (ASTRID MINI BRAC MOUNT OR APPROVED EQUAL) �P • POTHOLE MAST ARM POLE FOUNDATIONS PRIOR TO ORDERING POLES AND MAST ARMS. *SEE DETAIL "C" 3 ® F=18' I N o O ®F=15' I 7] CSC GREEN A n 6 06 PPB 1 LOCATE EVPE DETECTOR ♦SINGLE FACE PHASE DIAGRAM 0 TOTAL - - - 1 1 2 •MASTARM">':' ON LEVEL PART OF Q ROTATE LUMINAIRE ARM 90 DEGREES LEFT z MAST ARM NOT SIGNAL COMMON 1 1 1 1 1 2 3s" USED #10 LUMINAIRE 2 2 2 2ITT EMERGENCY VEHICLE PRE—EMPTION DETECTOR 45" Q11 �2 �3 �4 TOTAL 3 3 1 3 3 2 � a 6 FLASHER 2 2 2 1 2 TRAFFIC SIGNAL MAST ARM MOUNTING DETAIL N --- .-. ONLY NOT NOT tat 1 1 1 1 � � MOUNT 017' USED USED DET. 02 2 OOP 04 2 2 @ $ 4 04 O SP—U 05 06 07 O$ 05 1 1 \ 3 DETECTION DESIGN SPEED: RAILROAD CANYON ROAD = 60 MPH CABLE 06 2 2 2 1 2 O _3(2 2"C, 2—DLC & 2 #6(FLASHER) TOTAL 3 3 3 5 8 (TYPE B) ®�CONDUCTORS BY TEL CO. � ; 1 5 � � - � O 4 R9-3a E(2 EA) 6 R S TO 8E DETERMINED 2"C, 2 �{6 (SIGNAL) O 6 W 2"C, 2 #6(FLASHER) EVP CABLE 1 2 3 3"C & PULLROPE, i i 2 _ 6 ' _ y� 6 -- - —•�_= CONDUIT SIZE 2.5' 3" 2" 3" .5'2,4" CONDUCTORS BY SCE 06P (• — 05 PERCENT FILL 23 26 26 26 22 19 5❑SP(PP#4463580E) � 06 3 CSC = CONDUCTOR SIGNAL CABLE 02 4 R9-3(2 EA) —° —G _ 5T 5T Rw - 2"C, 2 #1O(LT 1' ASHING 2 1 CONTROLLER DETECTOR BEACON & 6 BARE �F) 2-�6�)¢ # ( )� � g 01,06 INPUT TYP N_ RW MOUNT 0 17' RW LIMIIT LI v _ m 1-01 1 6( < 50+74.85 05 z —'Rw5 DETAIL "A" 02,05 6 v YON R3-4 4 ROAD 950' TO 03 RO^0 GnN 1_05(5 04 6 02 4 R9-3a 04 — — LIMIT LINE _ _ n i M n 04 04 in It 5 EP g5 oN — �_ 6T �2 CONSTRUCTION NOTES (THIS SHEET): N � R9_3 4 10-CONTRACTOR SHALL FURNISH AND INSTALL A ECONOLITE T52 TYPE II ASC/25-2100 SYSTEM CONTROLLER a 5 10 R9-3a 4 O ASSEMBLY COMPLETE IN UNPAINTED ALUMINUM TYPE"P" CABINET. INSTALL BATTERY BACK-UP SYSTEM (BBS) A� 11 LINE / 2"C, 2-DLC & 2 #6(FLASHER) ,yI IN SEPERATE CABINET ON SIDE OF CONTROLLER CABINET. FOUNDATION SHALL EXTEND 18" ABOVE GRADE. ��/ It I l 38' SEE SPECIAL PROVISIONS. Z, s 35' 2o-CONTRACTOR SHALL FURNISH AND INSTALL A TYPE III-BF SERVICE EQUIPMENT ENCLOSURE WITH THE FOLLOWING CIRCUIT BREAKERS: \ EP ONE 120/24OV-100A(MAIN) / 1I161 ONE 120V-50A METERED SIGNALS) ONE 120V-40A UNMETERED UGHTING) ONE 120V-15A METERED IISNS) .4,n / GENERAL NOTES (THIS SHEET): ONE TYPE V P.E.C.(UGHTING &SIGNS) 5T 1. ALL ITEMS TO BE FURNISHED AND ALL WORK TO BE DONE SHALL CONFORM TO THE 9. UNGROUNDED SIGNAL CONDUCTORS SHALL NOT BE SPLICED. 3o-CONTRACTOR SHALL FURNISH AND INSTALL TYPE 9B CANTILEVER FLASHING BEACON, C. REQUIREMENTS OF: THE STATE OF CALIFORNIA, DEPARTMENT OF TRANSPORTATION W3-3 SIGN, INCANDESCENT LIGHTING FIXTURE AND FLASHING BEACON CONTROL ASSEMBLY CALTRANS STANDARD PLANS AND SPECIFICATIONS, DATED JULY 2002; CALTRANS 10. ALL PULL BOXES SHALL BE No. 5, UNLESS OTHERWISE NOTED ON THE PLAN. PER CALTRANS JULY, 2002 STANDARD PLANS ES-7K AND 7L ,s _ 2"C, 2 #6(FLASHER) ( ) N I � 5T TRAFFIC MANUAL; AND THE SPECIAL PROVISIONS. 11. PULL BOXES SHALL NOT BE LOCATED IN OR WITHIN 1' OF ANY CURB ACCESS RAMP. CONTRACTOR SHALL FURNISH AND INSTALL SIGN(S) AS SHOWN _ H .2. UTILITIES SHOWN ON THESE PLANS ARE CORRECT AND ACCURATE TO THE EXTENT OF 12. MAST ARM MOUNTED SIGNS SHALL BE FABRICATED WITH HIGH INTENSITY REFLECTIVE SHEETNG. 'n!AVAILABLE RECORDS. THE CONTRACTOR IS REQUIRED TO TAKE STEPS TO ASCERTAIN CONTRACTOR SHALL FURNISH AND INSTALL TYPE H RISER PER SCE REQUIREMENTS. CONTRACTOR L� 5❑— 3 THE EXACT LOCATION OF ALL KNOWN SUBSTRUCTURES PRIOR TO DOING WORK THAT 13. THE CONTRACTOR SHALL VERIFY WITH THE ENGINEER THE PRECISE FIELD LOCATIONS OF ALL SHALL CONTACT LES MONTGOMERY, SCE PROJECT MANAGER, AT 951-928-8237 PRIOR TO N (n z MAY DAMAGE OR INTERFERE WITH SUCH FACILITIES("UNDERGROUND SERVICE ALERT" TRAFFIC SIGNAL EQUIPMENT PRIOR TO INSTALLATION. INSTALLATION. (800) 422-4133). 14. MAST ARM MOUNTED STREET NAME SIGN SHALL BE DOUBLE SIDED, DIAMOND GRADE CONTRACTOR SHALL FURNISH AND INSTALL OPTICOM PRE-EMPTION DETECTOR MODEL 711. �—3. THE CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS AND NOTIFY ALL AFFECTED REFLECTIVE MATERIAL PER CITY SPECIAL PROVISIONS. CONTRACTOR SHALL FURNISH AND INSTALL OPTICOM PRE-EMPTION MOUNTING HARDWARE a 9 p0 AGENCIES AND UTILITY COMPANIES A MINIMUM OF 72 HOURS PRIOR TO START OF AND CABLE, SEE DETAIL"B" AND THE SPECIAL PROVISIONS. CONSTRUCTION. CONTRACTOR SHALL CONTACT SCE FOR LOCATION OF SERVICE POINT. z m __CONTRACTOR SHALL FURNISH AND INSTALL 2" CONDUIT AND PULLROPE PER GTE REQUIREMENTS. 0 4. UNLESS SHOWN OTHERWISE, INDUCTIVE LOOPS SHALL BE TYPE "E" WITH 10' SPACING CONTRACTOR SHALL CONTACT GTE PRIOR TO INSTALLATION FOR SERVICE POINT LOCATION. 3:DETAIL »C,9 IN THE DIRECTION OF TRAVEL LOOP WIRE SHALL BE TYPE 2. LOOP SEALANT SHALL BE INSTALL ALUMINUM NEMA ENCLOSURE ON SIDE OF CONTROLLER CABINET. a HOT-MELT RUBBERIZED ASPHALT PER STATE STANDARD 86-S.01A(S). NECESSARY STRIPING SHALL BE LOCATED PRIOR TO POSITIONING DETECTORS. IMPORTANT NOTICE UNDERGROUND STRUCTURES / POLE LOCATION 5. CONDUCTOR SCHEDULE IS FURNISHED AS AN INSTALLATION GUIDELINE ONLY. IT SHALL BE a ALL UNDERGROUND UTILITIES OR STRUCTURES REPORTED BY THE OWNER OR OTHERS AND THOSE SHOWN ON THE Z THE CONTRACTOR'S RESPONSIBILITY BWTY TO PROVIDE THE CORRECT CONDUCTORS REQUIRED SECTIONR421E-4217 OF THE GOVERNMENT RECORDS EXAMINED ARE INDICATED WIN THEIR APPROXIMATE LOCATION AND EXTENT,THE OMER BY ACCEPTING O FOR THE INTENDED OPERATION. THESE PLANS HAVE BEEN REVIEWED FOR COMPLIANCE WITH THE APPROVED CODE REQUIRES A DIG ALERT IDENTIFICATION THESE PLANS OR PROCEEDING WITH IMPROVEMENTS PURSUANT THERETO AGREES TO ASSUME UABIUTY AND TO N NUMBER BE ISSUED BEFORE A CONDITIONS OF DEVELOPMEN AND/OR CITY AND STATE LAWS,AND A PERMIT PERMIT TO EXCAVATE' WILL BE VALID HOLD UNDERSIGNED HARMLESS FOR ANY DAMAGES RESULTING FROM THE EXISTENCE OF UNDERGROUND UTILITIES J E.C.R. 6. ALL VEHICLE HEADS SHALL BE 12" LE.D. WITH GLASS LENSES. THE HOUSING, BACKPLATES 7 SS� � OR STRUCTURES NOT REPORTED TO THE UNDERSIGNED:NOT INDICATED ON THE PUBUC RECORDS EXAMINED:THE A I CAN ISSUED FOR YOUR DIG ALERT ID NUMBER CALL O AND VISORS SHALL BE METAL PLASTIC VEHICLE HEADS AND LENSES ARE NOT PERMITTED. CONTRACTOR IS p\ REQUIREDUT TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES OR STRUCTURES A u.. UNDERGROUND SERVICE ALERT SHOWN AND ANY OTHTHERR UTILITIES OR STRUCTURES FOUND AT THE SITE.IT SHALL BE THE CONTRACTOR'S K KtsA! SEu-d LO SL 91 r- to%f�T TOLL FREE T-800-422-4'133 RESPONSIBILITY TO NOTIFY THE OWNERS OF THE UTILITIES OR STRUCTURES CONCERNED BEFORE STARTING WORK. 0_ B 7. PEDESTRIAN INDICATIONS SHALL BE L.E.D. TYPE A WITH INTERNATIONAL SYMBOLS. TWO WORKING DAYS BEFORE YOU DIG. N B8. CONDUIT BETWEEN ADJOINING PULL BOXES SHALL BE 2" UNLESS SHOWN OTHERWISE. RE)BERT K. CITY ENGINEER RCE# 63B5S DATE < zo o zo ao so A�n^sw.P J«Sy,�-�.d Ala-4 r r 7 �/r a EXACT LOCATION BY - --° ., REVISIONS o ENGINEER IN THE FIELD 6 PI-ANNIN� n OLSIGN n CONSTRUCTION TRAFFIC SIGNAL PLAN SHEET ai GRAPHIC SCALE. 1" = 20' Qppf ESf/p�9 •` A 04�� RAILROAD CANYON ROAD r z7555rnEZ ROAD,SUITE 4D0 1 aI TEMECULA CALFORNIA 92591-4679 AT 1 0 DESIGNED: SCALE: No.57535 SIGNAL STANDARD CON 5 U LT�I N L3 909.678.8042• FAX 909.878.7240• wwwABF.wm PLACEMENT DETAIL GT 1"=zo' Exp,12-31-05 CHURCH ROAD T NO SCALE DRAWN: sj PLANS PREPARED UNDER THE SUPER SION OF: OS'Z a CHECKED: GT DATE:DATE:JOB NUMBER: 9rFOF C0% DATE: 9/27/05 CITY OF LAKE E L_S I N O R E OF 2 6HT5. _ o DATE BY NO. DESCRIPTION APP'D DATE CAD 10-104472 CARLOS A. ORTIZ R.C.E. 57535