Loading...
HomeMy WebLinkAboutGRAPE ST 31700 (11)CITY OF LADE ` LSIrIOR,E BUILDING & SAFETY r DREAM EXTREME,. 130 South Main Street PERMIT PERMIT NO: 10-00001040 JOB ADDRESS . . . . . : 31700 GRAPE ST DESCRIPTION OF WORK . : ELECTRICAL OWNER WALMART STORES INC. PO BOX 8050 BENTONVILLE AR 72716 A.P.# . . . . . 363-140-038 0 OCCUPANCY . . . . CONSTRUCTION . . . VALUATION . . . 30,000 DATE: 12/15/10 CONTRACTOR ABSOLUTE POWER SYSTEMS P.O. BOX 800985 SANTA CLARITA, CA 91380 661-775-7893 LIC EXP 0/00/00 SQUARE FOOTAGE 0 GARAGE SQ FT 0 FIRE SPRNKLR . ZONE . . . . . . (SP) BUILDING PERMIT QTY UNIT CHG ITEM CHARGE BASE FEE 352.00 5.00 X 9.0000 VALUATION 45.00 ELECTRICAL PERMIT QTY UNIT CHG ITEM CHARGE BASE FEE 30.00 1.00 X 27.2500 100-200AMP SERVICE<600VLT 27.25 1.00 X 16.2500 MISC. WHERE NO OTHER FEE 16.25 FEE SUMMARY CHARGES PAID DUE PERMIT FEES BUILDING PERMIT 397.00 202.00 195.00 ELECTRICAL PERMIT 73.50 57.25 16.25 OTHER FEES PROF.DEV.FEE 2 TRADES 10.00 10.00 00 PLANNING REVIEW FEE 79.40 79.40 00 PLAN. RETENTION FEE 17.85 17.85 00 MSEISIC OTHER 50 50 00 PLAN CHECK FEES 297.75 297.66 09 TOTAL 876.00 664.66 211.34 SPECIAL NOTES & CONDITIONS SOLAR PANELS FOR WAL-MART Olia: @AfEF2 Type: IF 3-de: 1 OaW.2/1511015 fkceipt_no: W 2D10 1090 g HIIL)m P6i1 1 sa l.39 Tram romp: _Iqm w Tres date; l?/15 10 Tiw; 14:33:07 City of Lake Elsinore /nm' Please read and initial Building Safety Division E-T— 1 am Licensed under the provisions of Business and professional Code Section 7000 et seq. and l/"[/'// my license is in full force. Trost In conspicuous Puce 2. Las owner of the pmperty,or my employees w/wages as their sole compensation will do the work on the job and the structure is not intended or offered for sale. 11, owner of the property,am exclusively contracting with licensed contractors to construct the You must furnish PERMIT NUMBER and the project. JOB ADDRESS for each respective inspection: 4. 1 have a certificate of consent to selfinsure or a certificate of Workers Compensation Insurance Approved plans must be on job or a certified copy thereof. at all times: 5. 1 shall not employ any person in any manner so as to become subject to Workers Compensation Laws in the performance of the work for which this permit is issued. Note: If you should become subject to Workers Compensation after making this certification, Approvals Date Inspector you must forthwith comply with such provisions or this permit shall be deemed revoked. Temporary Electric Service Gu[ dameIIlibrlilvjty{Yr MII.Y rJtnp.s I..MSoil CW Qj Tylp; jF jj^: I e r (e r A7fe: 10/07/10 07 %mript no: 16ff I, D2scriptlon (baltlty ram llt N ve v4 L M10 10gO IP aWD&i P849f I.OD M.6( SSOI TeId3• Mai I IXOiDk 31ED M.6( Total tt3 dRVd M.6( Total pit M•6( Tray date: ]0/07/10 Title: 13:90 2` THIS IS YQR R Effyr " Pie UndergroundFElectricConduitUnderground Footings J- S- I Steel Reinforcement BP03 Grout BP04 slab Grade 1 ' 1 fr2 PL01 Underground Water Pipe Rough Septic System S WO 1 On Site Sewer BP05 Floor Joists BP06 Floor Sheathing BP07 Roof Framing BPO8 Roof Sheathing BP09 Shear Wall & Pre -Lath PL03 Rough Plumbing EL03 Rough Electric Conduit I s- 1I EL04 Rough Electric Wiring C) 46 T1f 4- r e Z-or.11 MAP, EL05 Rough Electric / T-Bar ME01 Rough Mechanical ME02 iDucts, Ventilating PLO4 Rough Gas Pipe/ Test P1,02 Roof Drains BP I O Framing &Flashing BP 12 Insulation BP13 Drywall Nailing BP1 I Lathing & Siding PL99 Final Plumbing EL99 Final Electrical 11 I ME99 Final Mechanical BP99 Final Building Code Pool & Spa Approvals Date inspector OTHER DIVISION RELEASES Deputy Inspector Department Approval required prior to the building being released by the CitP00IPoolSteelRein. / Forms POO I Pool Plumbing / Pressure Test P003 Pre-Gunite Approval Date Inspector EL06 Rough Pool Electric Planning Sub List Approval Landscape P004 JP,,l Fencing / Gates / Alarms Finance P005 Pre -Plaster Approval Engineering P009 I Final Pool / Spa R. 1 C I T Y O F LAKE.;,) LSIAOPE DREAM EXTREMETM APPLICATION FOR BUILDING PERMIT VALUATION CALCULATIONS 1st FLOOR SF 2nd FLOOR SF 3rd FLOOR SF GARAGE SF STORAGE SF DECK 8 BALCONIES SF OTHER: SF VALUATION: A FEES BUILDING PERMIT PLAN CHECK PLAN REVIEW SEISMIC PLAN RETENTION 1 certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above - mentioned property for insp- tion purposes. Signature of Applicant or Agent Date Agent for contractor owner Agents Name Agents Address 130 South Main Street APPLIC ON ND A LICATI EC D DATE AV 9 363530006-6 BY ADDRESS 31700 Grape St., Lake Elsinore, CA 92532 O A E LOT/PARCEL o NAMEWAL-MART REAL ESTATE BUSINESS TRUST W N MAIL ING PHONE ADDRESS 2001. SE LOTH ST. 479.204. 1118 R CI BENTONVILLE STATE/ZIP AR 72716 C O N hereby affirm that I am licensed under provisions of chapter 9 (commencing with section 7000) of division 3 of the business and professions code,and my license is in full force and effect. LICENSE-# CITY BUSINESS AND CLASS TAX # T R E A C MAILING ADDRESS T 0 CITY STATE/ZIP PHONE R frE A NAME JAYME GARCIA LICENSE# E18930 R C ADDRESALI S 4614 2ND ST., STE. 4 H CITY STATE/ZIP PHONE DAVIS CA 95618 530-747-2026 NEW OCC GRP./ B2-Retail CONST. DIVISION: TYPE: ADDITIONALTERATION NUMBER OF NUMBER OF STORIES: BEDROOMS: ElOTHERSINGLE FAMILY APARTMENTS ZONE: 0 CONDOMINIUMS HAZARD YES AREA? NO TOWNHOMESCOMMERCIAL SPRINKLERS YES REQUIRED? NO IINDUSTRIALREPAIR PROPOSED USE OF BLDG. PRESENT USE OF BLDG: Retail DEMOLISHJOB DESCRIPTION This project entails the installation of a photovoltaic(PV)system. This installation consists of a new rooftop mounted PV system, which will be static mounted. Oper: MKFE Fe Tye: IFnpn 4 bat& W CITY OF LADE C LSI 0R.E i- w DREAM PROPERTY ADDRESS: Contact Person: COMMUNITY DEVELOPMENT BUILDING DIVISION PLAN CHECK SUBMITTALS Telephone No. Permit Application No Date I" Submittal: InitiPlan Checker: Da te toreturned from Plan Check: l/ Status: Date notified Applicant: Date Picked up: Initial: Applicant Date 2Id Submittao 0/G 1 iti Plan Checker: Date returned from Plan Check: Status: rz Date notified Applicant: Date Picked up: Initial: I I I V Applicant Date 3Submittal i ..; J / Initi Plan Checker: 4 /. d : s-' Date returned from Plan Check: Status: w A o Date notified Applicant: o/////O Date Picked up: Initial: Applicant Planning Approval: DATE Sent: DATE APPROVED: Engineering Approval: DATE Sent: DATE APPROVED: Fire Dept. Approval: DATE Sent: DATE APPROVED: DATE Received School Fee (If Area > 500 SF): DATE Received Health Department Approval: Location: Date Permit Issued: Tech: U:\Building & Safety\Forms\Planchecklog.doc Created on 8/8/2008 1:51:00 PM CITY OF LAKE ELSINORE CONSTRUCTION PLAN REVIEW COMMENTS (BP10-1040) PHOTOVOLTAIC (PV) SYSTEM FOR WALMART Prepared By: Matthew Harris, Senior PlannerDate: September 28, 2010 Planning staff has reviewed the construction drawings associated with the above noted project and provides the following comments: Elsinore City Center Specific Plan, Chapter IX Design Guidelines, Section 21 Mechanical Equipment states: Rooftop equipment shall not be visible from off -site public rights -of -way. Rooftop equipment features shall be provided as an integral aspect of the building design." Sheet ES-201 — Line of Sight Elevations states "no major portion of the modules or related rooftop equipment will be visible." Therefore, staff requests that additional information be provided on the plans to demonstrate that all rooftop equipment will be completely screened from adjacent rights - of -way. The overall dimension(s) of the highest point of the film modules from the existing roof elevation(s) should be provided along with adjacent roof parapet heights as necessary so as to demonstrate compliance with the screening requirement. Please contact me at (951) 674-3124 Ext. 279 should you have any questions regarding this matter. BLUE OAK ENERGY, INC. City of Lake Elsinore Date Type Reference 9/29/2010 Bill 9/29/2010 Original Amt. Balance Due Discount 482.60 482.60 Check Amount 3480 Payment 482.60 482.60 CBB Checking 482.60 RealQuest.com ® - Report Page 1 of l Property Detail Report For Property Located At CoreLogic' RealQuest, 31700 GRAPE ST, LAKE ELSINORE, CA 92532-9785 Professional Owner Information: Owner Name: WALMART STORES INCIWAL-MART R ALTY CO Mailing Address: PO BOX 8050, BENTONVILLE AR 7271 8055 B050 Phone Number: Vesting Codes: Location Information: Legal Description: 12.39 ACRES MIL IN POR PAR 1 PM 1821089 PM 27659 County: RIVERSIDE, CA APN: Census Tract / Block: 464.04 / 1 Alternate APN: Township -Range -Sect: Subdivision: Legal Book/Page: Map Reference: Legal Lot: 1 Tract #: Legal Block: School District: Market Area: Munic/Township: Neighbor Code: Owner Transfer Information: Recording/Sale Date: 07/26/2006 106/28/2006 Sale Price: Document #: 544705 Last Market Sale Information: Recording/Sale Date: 08116/1996 / Sale Price: 4,060,000 Sale Type: FULL Document #: 311013 Deed Type: WARRANTY DEED Transfer Document #: New Construction: Title Company: Lender: Seller Name: WAL MART STORES INC Prior Sale Information: Prior Rec/Sale Date: I Prior Sale Price: Prior Doc Number: Prior Deed Type: Property Characteristics: Year Built / Eff: / Total Rooms/Offices: Gross Area: Total Restrooms: Building Area: Roof Type: Tot Adj Area: Roof Material: Above Grade: Construction: of Stories: Foundation: Other Improvements: Exterior wall: Basement Area: Site Information: Zoning: Acres Flood Zone: X Lot Area: Flood Panel: 0606362066F Lot Width/Depth: Flood Panel Date: 08/18/2003 Commercial Units: Land Use: MMERCIAL Building Class: Tax Information: Total Value: 12,477,240 Assessed Year: Land Value: 6,574,395 Improved %: Improvement Value: 5,902,845 Tax Year: Total Taxable Value: 12,477,240 Deed Type: 1st Mtg Document #: 1 st Mtg AmountlType: 1st Mtg Int. Rate/Type: 1 st Mtg Document #: 2nd Mtg Amount/Type: 2nd Mtg Int. RaterType: Price Per SgFt: Multi/Split Sale: Prior Lender: Prior 1st Mtg Amt(Type: Prior 1st Mfg Rate/Type: Garage Area 363-530-006 363-530-006 866-J6 LAKE ELSINORE GRANT DEED MULTIPLE Garage Capacity: Parking Spaces: Heat Type: Air Cond: Pool: Quality: Condition: 12.39 County Use: 539,708 State Use: x Site Influence: Sewer Type: Water Type: 2010 Property Tax: 47% Tax Area: 2010 Tax Exemption: COMMERCIAL Cl) C03000 130,777.72 5026 http://pro.realquest.com/j sp/report.j sp?&client=&action=confirm&type=getreport&record... 12/15/2010 13P200I03 City of Lake Elsinore 9/28/10 Application Inquiry - Fees 11:44:09 Application number: 10 00001040 Property 31700 GRAPE ST Fee Class/Type/Description Trans amt Amt due Struct Permit Insp A E2 PROF.DEV.FEE 2 TRADES 10.00 10.00 K PC PLAN CHECK FEES 297.75 297.75 000000 BLDG00 P PF PERMIT FEES 57.25 57.25 000000 ELEC00 P PF PERMIT FEES 397.00 397.00 000000 BLDG00 A PR PLANNING REVIEW FEE 79.40 79.40 A RT PLAN RETENTION FEE 17.85 17.85 A SO SEISMIC OTHER 50 50 Credit fees due: .00 Revenue fees due: 859.75 Total due: 859.75 Press Enter to continue. F3=Exit F11=Change view F12=Cancel F10=Amt billed 77 Bottom 0 BLUE OAK ENERGY, INC. City of Lake Elsinore Date Type Reference 9/9/2010 Bill 9/9/2010 Original Amt. Balance Due Discount 182.06 182.06 Check Amount 3428 Payment 182.06 182.06 CBB Checking 182.06 OCT-19-2010 TUE 11:01 AN FAX NO. P. 131/01 Riverside County Fire Department Fire Protection Planning Section RhemklR Ofto: 2000 MRM.t S4, S1e. 150, F0vR9ddR, CA 02e01 Ph. (01) 95"M Fax (9511665-4BB6 PRIm raven cft-:77A33 IA, M.M.8. Rd., 9201 palm p9wt, CA 922)1.1131 Mi. (760) 863-B B B6 Fax(76M 064.7072 Fire Department Clearance/Release Date:_ I ' 19 -2-0I 0 To: "e. i SI flOi`e Fax:- 949 1- IHJ Tract/Parcel Map #: Permit/Lot #: / 0 — Final For Recordation Release For Building Permit(s) Shall Final Only (No Tenant) Final For Occupancy Building Plan Check Fees Paid FPP(Kc 5335-4p Building Plan Check Fees Not Paid Other Fees Fees Not Required If you should have any questions, please contact the appropriate Riverside County Fire Protection Planning office for further assistance. I Authorizing Signature For Release AANITA L. WARD Print Name Fc" C— RRhRed 1128/09 OCT-19-2010 TUE 12:34 NM FAX NO. P. 01/01 Riverside County Fire Department Fire Protection Planning Section Rhunlde Cllka: 2000 Merkel St., Ste, 150. RMamlde, CA 025111 Ph. 18511 epd•q%%% Faa(051 1955 885 Palm Pawn Cfflae: 77- 33 lus Mcnra5al 8d.. A I01 Palm Palarc, CA 622 11-4 1 B I Ph, (7501 853 SEES Fax 060) B63.7077 Fire Department Clearance/Release Date: I D ' 19 —0201 O To:F tSinare Fax: 49 1— 14f Tract/Parcel Map #: Permit/Lot #: Job Site Address E 17 C7 C ra 4!0 a --St- Final For Recordation Release For Building Permit(s) Shell Final only (No Tenant) Final For Occupancy Building Plan Check Fees Paid r'PA"fZC rj 335—(p Building Plan Check Fees Not Paid Other Fees Fees Not Required If you should have any questions, please contact the appropriate Riverside County Fire Protection Planning office for further assistance. A F/t1 !, Authorizing Signature For Release n / Ala4p`Y'a 4... V4VARD Print Name Fmm C— Revleed 1n5105 EXISTING CUTLER -HAMMER NOTE: THE DESIGN OF THE TAPS 480V 3PH 3W TO EXISTING CUTLER-HAMISERVICE 2500A MAIN DISTRIBUTION APPLIES NEC BENDING SPACES 2500A 2500A 3PH 4W MAIN DISCONNECT SECTION SWITCHBOARD SERVICE AS INDICATED IN TABLES 312.6(A) DISCONNECT SECTION 312.6(B). BUS ALSTAN 80 TIN PLATED ALUMINUM RIGHT SIDE VIEW 2) 4/0 COMPRESSION TYPE LUGS ( BYOTHERS) O PV Sp{IRCEcormvm NEW BUS FLAGS FOR PV SOURCE INPUT CONDUCTORS. FLAGS CONTAIN MOUNTING THIS CONNECTION TO AN EXISTING SWITCHBOARDDOLESFORSINGLEBOLTMOUNTINGWITHFOLLOWSU.L. 891 STANDARD 17OR DEAD -FRONTSTAINLESSSTEELHARDWARE. HARDWARE FOR LUGS TO BE PROVIDED BY CONTRACTOR. SWITCHBOARDS. ALTHOUGH T1IE U.L. LABEL CANNOT BE ZINC PLATED HARDWARE FOR BUS FLAG FIELD APPLIED, HAD WE PROVIDED THIS TYPE OF CONNECTIONS TO EXISTING BUS IS PROVIDED. CONNECTION IN OUR MANUFACTURING FACILITY WE SEE BILL OF MATERIAL BELOW. WOULD HAVE MET THE U.L. 891 STANDARD, AND COULD AFFIX A LABEL. I pfE5Sl0M'C C• C,4 F(. SEE ENLARGED VIEWS ON PLEASE NOTE, 00e R A liy THE CONTRACTOR IS RESPONSIBLE TO PROPERLY TIGHTENDRAWINGOTI0583-2 Q 3l Fn ALI. BOLTS AND LUG CONNECTIONS IN ACCORDANCE WITH THE TORQUE7061em1 LABEL PROVIDED. q Tip• w EXP• C YOU MAY ALSO BE ASKED TO PROVIDE A LETTER TO THE INSPECTION AUTHORITIES CERTIFYING THE ABOVE BEFORE2 TOP rHE INSPF.CTER WILT. APPROVE'THIS INSTALLATION. INSTALLATION A TORQUE SPECIFICATION LABEL WILL BE INCLUDED WITH THE SHIPMENT FOR THE PROPER TIGHTENINGOF THE BOLTS PROVIDED FORTHIS CONNECTION. T-BOX \29 I I REFER TO TORQUE VALUE LA BEL PROVIDED WTTH MINIMUM SPACINGS(600V) BILL OFMATERIAL BUS BAR CONNECTING SHIPNIENTOF LUG TAP ASSEMBLY. IF ]HELLO SIZE IS NOT REFERENCED USE THESE VALUES, HARDWARE IS GRADESDESCRIPTION MINOIUKI SPACING BETWEEN UVP. NBNIMIT51 SPACING THROUGH AIRPARTS ZINC PLATED, AND MATCHES socl:e,TSIZE nriHTNTNC TORQUE FOR SO(:Rt:T X2-1/4°GR. SCARRIAGE BOLTS L. ACROSS FLATS HEAD S(REWS AND POLARITYOPPOSITEPOLARITY OVER SURFACE BETWEEN LIVE PARTSTHEEXISTINGPROVIDEDBti' H(Pour 5NCi¢SISSFLATWASHERSAND GROED !.TAL PARTS UNDCUTLER - HAMMER. NAVY DUTY LOCK WA54IER5 Ila vs ITI4THROUGH AIR OVER SURFACE EX NUTS 513, 1w IV, z o' To - FLAGS W/LUG MTG. HOLE 3116 I Im IV m0 THIS TAP ASSE%MLY IS NOT STANDARD PRODUCT EACH TAP ASSEMBLY IS CI TDVI 5116 275 DESIGNF..DTOMEETTHEE\TSTINGCONDITIONS. WHILE EVERY EFFORT IS MADE TO 318 375 PROVIDEA PROPER TAP ASSEMBLY.'DIB INSCALLING CONTRACTOR SHOL. VERIFY le 5w INADVANCETHATOMN". SPACINGSLISTEDABOVEWILLBEhMTANDIFFOUNp all6 600 TOLUANCORRECT ONOr1NrAI1 C tlla' q- DATE: 1/24/11 SHEET I OF 1 4` Pacific Electric, Inc. CONTRACTOR MARK e El 42640 Rio NedD "Temecula, Ca. 92590 ABSOLUTE POWER SYSTEMS en Carey ( 951)296-1562 DISTRIBUTOR P, O. NO, UxnWNBY: PROJECT: WAL-MART /PHOTOVOLTAIC SYSTEM CED-SAN DIEGO 7125vR949431D DC 31700 GRAPE GAIT: BY REVISIONS SCALE LAKE ELSINORE, CA DRAWINGNO. 1 T10583-1 DATE I BY I REVISIONS TOP VIEW DRAWN BY: DC SCAUNTS SIDE VIEW Pacific Electric, Inc. 42640 Rio Nedo Temecula, Ca. 92590 95 1) 296-1562 WAL-MART / PHOTOVOLTAIC SYSTEM 31700 GRAPE LAKE ELSINORE, CA DATE: 1124/1) CONF ACTOR ABSOLUTE POWERSYSTEMS DISTRIBUFOR CED-SAN DIEGO SHEET I OF I MARK PA. NO. 7125VR949431D DRAWING NO. I T 1. 05 83 -2 Absolute PowerAbsolutePowerSystemsP.O. Box 800985Systems Santa Clanta, CA 91380 February 15, 2011 City of Lake Elsinore Community Development ATTN: Bill Belvin 130 South Main Street Lake Elsinore, CA 92530 I:fiNII PUNL[rL9: Dear Mr. Belvin: Voice : (661) 775-4893 Fax : (661) 775-4873 Regarding the solar roof top project at Wal-Mart, located at 31700 Grape Street, We performed the interconnect of the solar system to the main switchboard. This was a bus tap. Spacer plates and mounting brackets were installed as per engineered drawings. Cables were attached to the mounting plates. The spacer plates and mounting plate were attached wit carriage bolts and the cables were attached using compression connectors wit 3/8" stainless steel hardware. All connections were torqued to the manufacturer's specifications. The connections were marked. The torque was then verified by Chad Day with Donco, the construction management company. Chavdar Christov, the BP Solar officer in charge also visually verified the dual marks and took photographs to substantiate the process. The torque settings tables were installed on the inside of the panel cover per a preprinted adhesive label. Please, feel free to contact me with any questions you may have. Sincerely, Frank G. Joga Owner Absolute Power Systems Absolute PowerAbsolutePowerSystemsP.O.Box 800985 Systems Santa Clarita, CA 91380 February 15, 2011 City of Lake Elsinore Community Development ATTN: Bill Belvin 130 South Main Street Lake Elsinore, CA 92530 RE: 10-00001040 Dear Mr. Belvin: Voice: (661) 775-4893 Fax : (661) 7754873 Regarding the solar roof top project at Wal-Mart, located at 31700 Grape Street, cable terminations were made at the safety switch, inverter and combiner boxes. All connections were torqued to the manufacturers specifications. The connections were marked. The torque was then verified by Chad Day with Donco, the construction management company. The manufacturer recommended torque settings were defined on labels within the equipment and in installation manuals. Please, feel free to contact me with any questions you may have. Sincerely, Frank G. Joga Owner Absolute Power Systems 714)254-0099 714) 254-0199 Fax Donco & Sons, Inc. Signs • Lighting • Electrical City of Lake Elsinore Community Development 130 South Main Street Lake Elsinore, CA 92530 ATTN: Bill Belvin RE, Solar Energy System Wal-Mart 31700 Grape Street Lake Elsinore, Ca Dear Mr. Belvim 1410 N. Daly St. Anaheim, CA 92806-1502 Donco and Son's is contracted by BP Solar to provide construction management services for the subject project. On behalf of BP Solar, our superintendent Chad Day provided quality assurance activities throughout the project. These activities included checking all torque readings for both the interconnection in the main switchboard at the bus taps as well as all mechanical connections for the racking system on the roof. All bolts were checked and marked with a pen to confine the torque had been checked against manufacturers recommendations. If you have any questions regarding this project, please feel free to call me at your convenience. Regards, Mike Norrell Donco Construction & Management, Inc. A Division of Donco and Sons Operations Manager 1410 N. Daly St. Anaheim, Ca 92806 CA. LICENSE #435616 B, C10,C45,C61 • AZ. LICENSE L38 #097661 L11 #098214 • AZ. Dba D & S Signage, Inc. z a EXISTING CUTLER -HAMMER 2500A MAIN DISTRIBUTION SWITCHBOARD SERVICE DISCONNECT SECTION NOTE: THE DESIGN OF THE TAPS APPLIES NEC BENDING SPACES AS INDICATED IN TABLES 312.6(A) & 312.6(B). SERVICE 400A 480V 3PH 3W TO EXISTING CUTLER -Hi 2500A 3PH 4W MAIN DISCONNECT SECTION BUS I ALSTAN 80 TIN PLATED ALUMINUM RIGHT SIDE VIEW LUGS (2) 4/0 COMPRESSION TYPE O ( BY OTHERS) PV SOURCECONDUIT NEW BUS FLAGS FOR PV SOURCE INPUT CONDUCTORS. FLAGS CONTAIN MOUNTING HOLES FOR SINGLE BOLT MOUNTING WITH STAINLESS STEEL HARDWARE. HARDWARE FOR LUGS TO BE PROVIDED BY CONTRACTOR. ZINC PLATED HARDWARE FOR BUS FLAG CONNECTIONS TO EXISTING BUS IS PROVIDED. SEE BILL OF MATERIAL BELOW. SEE ENLARGED VIEWS ON DRAWING OT10583-2 TOP VIEW w l BILL OF MATERIAL Ty DESCRIPTION 6 3/8-16 X 2-1/4" GR. 5 CARRI 6 3/8 USS FLAT WASHERS 6 3/8 HEAVY DUTY LOCK W 6 3/8 HEX NUTS 3 BUS FLAGS W/LUG MTG. I DATE I BY REVISIONS F15060I BUS BAR CONNECTING HARDWARE IS GRADE BOLTS ZINC PLATED, AND MATCHE.' THE EXISTING PROVIDED BY REFER TO TORQUE VALUE LABEL PROVIDED WITH SHIPMENT OF LUG TAP ASSEMBLY. IF THE LUG SIZE IS NOT REFERENCED USE THESE VALUES. SOCKET SIZE I TIGHTENING TORQUE FOR SOCKET ACROSS FLATS HEADSCREWS INCH) (POUND -INCHES) THIS CONNECTION TO AN EXISTING SWITCHBOARD FOLLOWS U.L. 891 STANDARD FOR DEAD -FRONT SWITCHBOARDS. ALTHOUGH THE U.L. LABEL CANNOT BE FIELD APPLIED, HAD WE PROVIDED THIS TYPE OF CONNECTION IN OUR MANUFACTURING FACILITY WE WOULD HAVE MET THE U.L. 891 STANDARD, AND COULD AFFIX A LABEL. PLEASE NOTE: THE CONTRACTOR IS RESPONSIBLE TO PROPERLY TIGHTEN ALL BOLTS AND LUG CONNECTIONS IN ACCORDANCE WITH THE TORQUE LABEL PROVIDED. YOU MAY ALSO BE ASKED TO PROVIDE A LETTER TO THE INSPECTION AUTHORITIES CERTIFYING THE ABOVE BEFORE THE BUILDING INSPECTER WILL APPROVE THIS INSTALLATION. A TORQUE SPECIFICATION LABEL WILL BE INCLUDED WITH THE SHIPMENT FOR THE PROPER TIGHTENING OF THE BOLTS PROVIDED FOR THIS CONNECTION. MINIMUM SPACINGS (600V) MINIMUM SPACING BETWEEN LIVE MINIMUM SPACING THROUGH AIR PARTS OF AND OPPOSITE POLARITY OVER SURFACE BETWEEN LIVE PARTS A THROUGH AIR OVER SURFACE AND GROUNDED METAL PARTS 1/8 4s 1.0" 2.0" 1.0" 5/32 100 3/16 120 CAUTION: THIS TAP ASSEMBLY IS NOT STANDARD PRODUCT. EACH TAP ASSEMBLY IS CUSTOM DESIGNED TO MEET THE EXISTING CONDITIONS. WHILE EVERY EFFORT IS MADE TO PROVIDE A PROPER TAP ASSEMBLY, THE INSTALLING CONTRACTOR SHOULD VERIFY IN ADVANCE THAT THE MIN. SPACINGS LISTED ABOVE WILL HE MET, AND IF FOUND 7/32 150 U4 200 5/16 275 3/8 375 1/2 500 Pacific Electric, Inc. 42640 Rio Nedo Temecula, Ca. 92590 951)296-1562 DRAWN BY: PROJECT: WAL-MART / PHOTOVOLTAIC SYSTEM D 31700 GRAPE S TS LAKE ELSINORE, CA DATE: 1/24/11 SHEET I OF I CONTRACTOR MARK ABSOLUTE POWE R SYSTEMS DISTRIBUTOR P.O. NO. CED-SANDIEGO 7125VR949431D DRAWINGNG. 1T10583-1 DATE I BY REVISIONS SIDE VIEW Pacific Electric, Inc. 42640 Rio Nedo Temecula, Ca. 92590 951)296-1562 DRAWN BY: PROJECT: WAL_MART / PHOTOVOLTAIC SYSTEM DC 31700 GRAPE SCNTSALE: LAKE ELSINORE, CA DATE: 1/24/11 CONTRACTOR ABSOLUTE POWER SYSTEMS DISTRIBUTOR CED-SAN DIEGO DRA W ING NO. SHEET I OF I P.O. NO, 7125 VR94943 ] D 1T10583-2