Loading...
HomeMy WebLinkAboutVISTA VIEW 15036_14-00001284 cITY OF Lgl(E LS1110RE BUILDING & SAFETY DREAM EXTREMETM 130 South Main Street PERMIT JOB ADDRESS . . . 15036 VISTA VIEW DESCRIPTION OF WORK ELECTRICAL OWNER CONTRACTOR SMOLLEN JAROLD SOLARMAX TECH SMOLLEN HELEN 3080 12TH STREET 15036 VISTA VIEW RIVERSIDE, CA 92507 LAKE 'ELSINORE CA 92530 951-300-0768 LIC EXP 0/00/00 A. P. # . . . 389-394-009 7 SQUARE FOOTAGE 0 OCCUPANCY . . . GARAGE SQ FT 0 CONSTRUCTION . . FIRE SPRNKLR VALUATION . . . 15 , 000 ZONE . . . . . . R-1 BUILDING PERMIT QTY UNIT CHG ITEM CHARGE BASE FEE 63 . 00 13 . 00 X 12 . 5000 VALUATION 162 . 50 ELECTRICAL PERMIT QTY UNIT CHG ITEM CHARGE BASE FEE 30 . 00 1 . 00 X 16 . 2500 MISC. WHERE NO OTHER FEE 16 . 25 FEE SUMMARY CHARGES PAID DUE PERMIT. FEES BUILDING PERMIT 225 . 50 . 00 225 . 50 ELECTRICAL PERMIT 46 . 25 . 00 46 . 25 OTHER FEES PROF.DEV. FEE 2 TRADES 10 . 00 . 00 10 .'00 PLANNING REVIEW FEE 45 . 10 45 . 10 . 00 PLAN RETENTION FEE 1 . 50 . 00 1 . 50 SEISMIC GROUP R . 50 . 00 . 50 PLAN CHECK FEES 169 . 13 169 . 13 . 00 TOTAL 497 . 98 214 . 23 283 . 75 SPECIAL NOTES_& CONDITIONS_ ROOF MOUNTED SOLAR 33 PV MODULES, 8 . 25 KW 1~ LA fi'' 12 tl". l d City of Lake Elsinore Please read and initial Building Safety Division 1.1 am Licensed under the provisions of Business and professional Code Section 7000 et seq.and my license is in full force. Post in conspicuous place 2.l,as owner of the property,or my employees w/wages as their sole compensation will do the work on the job -id the sm!cVure is not intendM o.offered for sale. 3.I,as owner of the property,am exclusively contracting with licensed contractors to construct the You must furnish PERMIT NUMBER and the project. JOB ADDRESS for each respective inspection: _4.I have a certificate of consent to selfinsure or a certificate of Workers Compensation Insurance Approved plans must be on job or a certified copy thereof. at all times: I 5.1 shall not employ any person in any manner so as to become subject to Workers Compensation Laws in the performance of the work for which this permit is issued. Note:If you should become subject to Workers Compensation after making this certification, Code Approvals Date Inspector you must forthwith comply with such provisions or this permit shall be deemed revoked. ELO 1 Temporary Electric Service PLOI Soil Pipe Underground EL02 Electric Conduit Underground BPOI Footings BP02 Steel Reinforcement BP03 Grout BPO4 Slab Grade PLOI Underground Water Pipe SSO1 Rough Septic System SWOT On Site Sewer BP05 Floor Joists BP06 Floor Sheathing BP07 Roof Framing EPOS Roof Sheathing BP09 shear wall&Pre.-Lath PL03 Rough Plumbing EL03 Rough Electric Conduit ELO4 Rough Electric Wiring y' EL05 Rough Electric/ T-Bar ME01 Rough Mechanical ME02 IDucts,Ventilating PLO4 Rough Gas Pipe/Test PL02 Roof Drains BP10 Framing&Flashing BP 12 Insulation BPI Drywall Nailing BPI 1 Lathing&Siding PL99 Final Plumbing EL99 Final Electrical a L O7& -7•Z ME99 Final Mechanical BP99 Final Building 9 Code Pool&Spa Approvals Date Inspector OTHER DIVISION RELEASES Deputy Inspector Department Approval required prior to the P001 Pool Steel Rein./Forms building being released by the City POOI Pool Plumbing/Pressure Test P003 Pre-Gunite Approval Date Inspector EL06 Rough Pool Electric Planning Sub List Approval Landscape P004 Pool Fencing/Gates/Alarms Finance P005 Pre-Plaster Approval Engineering P009 Final Pool/Spa CITY OF LAKE L S I IJO E DREAM. EXTREME TM 130 South Main Street APPLICATION FOR AP LrTION <S BUILDING PERMIT DATE APPLICATION RECEIVED VALUATION CALCULATIONS BUI DING ADDRESS 1st FLOOR SF auo c BLOCKIPAGE LOT/PARCEL 2nd FLOOR SF NAME),,. , 3rd FLOOR SF O W A L dd o H NE GARAGE SF N ADDRESS1 �(� ?Lx? vj STORAGE SF R CITt aK i � e STATE/ZI . I hereby affirm that I am licensed under provisions ot chapter 9(commencing DECK&BALCONIES SF with section 7000)of division 3 of the business and professions code,and C my license is in full force and effect. OTHER: SF O LICENSE# TCITY AX#BUSINESS N AND CLASS '""( �3 (�t n T NAMES y VALUATION: Z— ( Q R �C7 LC l( A AILIN C ADDRESS 30�T `} FEES T C Y STA E/ZI 11 HO E"I/�yl BUILDING PERMIT 3 R MIN T I NA R UK i l PLAN CHECK 4an 6 l' NAM LICENSE 4 A PLAN REVIEW 5 101 0 R MAILING C ADDRESS SEISMIC H CITY STATE/ZIIP PHONE PLAN RETENTION ❑NEW OCC GRP./ CONST. ❑ADDITION DIVISION: TYPE: FIRE SERVICES ❑ALTERATION NUMBER OF NUMBER OF OTHER STORIES: BEDROOMS: SINGLE FAMILY ZONE: ❑APARTMENTS ❑I certify that I have read this application and state that the ❑CONDOMINIUMS HAZARD YES above information is correct.I agree to comply with all city 0 TOWN HOMES AREA? NO and county ordinances and state laws relating to building COMMERCIAL SPRINKLERS YES construction,and hereby authorize representatives of this ❑INDUSTRIAL REQUIRED? NO city to enter upon the above-mentioned property for insp- ❑REPAIR PROPOSED USE OF BLDG: tion purposes. ❑DEMOLISH PRESENT USE OF BLDG: JOB DESCRIPTION r t / � - a �-� u ' ! ► rG Si e f Applicant or Agent Date Agent for contractor El owner Agents Name cam"= Agents Address 5byo 12. 1 2 &j rr� td& -CA 01750 -Z LION 1 1P WILDING PERqrr = Tram rye 177107 M O-ECK 182 oq. 3 Tram ate. 5/21/14 Titre. 11.M42 00 SPi NEW 20OA/200A TOP FED PITCH: 19° SERVICE POINT&UTILITY METERING \ AZIMUTH: 170° (N)60A AC DISCONNECT 1 MATERIAL: RAT CEMENT / SOW MAX RENEWABLE STORIES: 2 (N)100A SOLAR EN�WIn—II- LOAD CENTER \ RWRSIM,G 92WT SP SQ.FT: 891.18 T 6'W x 42"D x 6'-6"H WORK AX:�+i2�M ARRAY SQ.FT: 376.18 4'-9"W x 42"D x 6'-6"H WORK �*�mx m„ CLEARANCE PER NEC 110.26(A)(1), CLEARANCE PER NEC o WALWK 110.26(A)(2) & 110.26(A)(3) sP2 110.26(A)(1), u bimwlw w— o.2s(A)(2) �2.ay RK�S+ & 110.26(A)(3) PITCH: 191 NEW PV CONDUIT TO 8E RUN WITHIN EVE AwTm°�m=s m AZIMUTH: 170° AND HIDDEN FROM VIEW. CONDUIT TO BE o.�+ ■ �ww aI WMNL m r w[ uwwL rWNW Ar MATERIAL: RAT CEMENT PAINTED TO MATCH EXISTING SURFACE. � � STORIES: z SP SQ.FT: 270.43 Front Of Residence ARRAY SQ.FT: 107.45 AZIMUTH: J17O')_ 15036 VISTA VIEW ROBERT UULIC.HOLDERS SIG. Spa PIT : �xE CONDUIT TO BE 19 5'REVERSE TILT ® ���\B\k RUN IN ATTIC ° \ AZIMUTH: 350° MATERIAL: RAT CEMENT STORIES: 2 SP SQ.FT: 553.30 \ Z ARRAY SQ.FT: 107.45 \\\ 3�� 'wcK 5�8p/K/ -��i\F `$ J EQUIPMENT LEGEND O gi (N) �- DISCRIPTION `�¢O YP O MAIN SERVICE PANEL w/WARNING LABEL seACK ® ® ® U) N O C, o m N I O OO DEDICATED PV SYSTEM METER d pt� tea, J C w LLI INVERTER w WARNING LABEL ® \ O \�P�sF � �� � �/ � 0 'S (BUILT-IN DO DISCO) -B O DISTRIBUTION PANEL w/WARNING LABFJ O ° LOAD CENTER w/wA1811Nc LABEL ® ® ® t� 0. 356.g z e OC DISCONNECT w/WARNING LABEL ® ® \\ E p.9-30 t O © AC DISCONNECT w/WARNING LABEL (RD ® JUNCTION BOX �t ® t, SAL � .4T LL QQ ® DC COMBINER BOX w/WARNING LABEL \ 2S—Y sMxaeaa 026 kW AL ACCESS LADDER wm„ M8I TXE NO°XS EXTERIOR CONDUIT RUN SITE PLAN „�� M2,6U032 =AG --------- INTERIOR CONDUIT RUN TOTAL ROOF SQ.FT: 2389.75 SCALE:I/W'=V-0" ANt L EELSI E SNEEi MIA.1lER: ----- - INTERIOR EQUIPMENT TOTAL ARRAY SQ.FT; 591.08 �� -o-- FENCE ARRAY COVERAGE: 25% SP# 1 PV MODULES 21 SMX-250P MOUNTING EQUIP. MSI TILE HOOKS RACKING SYSTEM EVEREST RAIL \ soL„kN PV SYSTEM HEIGHT 9" \ ENER°Y VI°EH INC PITCH 19° a�91M.�2, \ ML ssll°an�ee AZIMUTH 170° r FAX:M1)21°aws sass#C-46LIC#97P°I° MATERIAL FALT CEMENT uwmm-u■� STORIES lz m mmm W�.N1O'■ SP SQ.FT 1891.67ffK�■ ■■' mrtm° ■=m ARRAY SQ.FT 376.18 ■van■..■.�■L■�r■ ARRAY% 42% AZIMUTH: 1701 RAFTER SIZE 2"X 4"TRUSS PITCH: 5° / 7ROBERT RAFTER SPACING 24"OC ` Front Of Residence MEAN ROOF HQ 24' S'REVERSE TILT '1` 4 15036 VISTA VIEW UUSP# 2 ��' ER•S SIG. e � PV MODULES 6 SMX-250P � MOUNTING EQUIP. MSI TILE HOOKS �R'2 \ � \ '\ LATERAL POINT LOAD RACKING SYSTEM EVEREST RAIL \ �+ `\ \�\` AT 11' (TYP.) PV SYSTEM HEIGHT 9" PITCH 19° AZIMUTH ° i a'a \ 1 MATERIAL FALT CEMENT ` ;\ SBpck 5 h4 W i \. „ A, 5 s s 3g J STORIES 2 m (� w -A SP J.FT 270.43 —� ` \ ,, m� tik ° ARRAY SQ.FT 107.45 ARRAY% 39% a, k cK \ , \ F z RAFTER SIZE 2"X 4"TRUSS m �� �cK \ \ >i RAFTER SPACING 24"OC \ Eis \ o w MEAN ROOF HEIGHT 24' \� \ \\` \a �r '\ O SP# PV MODULES (6)SMX-250P "\ \ t \ `, \ \ \ \•MIX ®4��FES �j MOUNTING EQUIP. MSI TILE HOOKS "1 \ RACKING SYSTEM EVEREST RAIL `t�P �� PV PITCH STEM HEIGHT 1"-APPROX.2'-10" �r. a ' \ \ \ \ �i 1 ® l' <? IS J AZIMUTH 350 '. � \ '\ •\` yam'\ \ � 9� n MATERIAL FALT CEMENT STORIES SP FT 553.30 N, ARRAY SQ.FT 107.45 g z sronv ARRAY% 19% A i���j`` sMz zsse RAFTER SIZE 2"X 4"TRUSS RAFTER SPACING 24"OC M9I TILE HOOK9 MEAN ROOF HEIGHT 24' F " M2,SB62LLSY2-IG ,y°, lal(E EL&NORE G ROOF PLANROUND METHOD NEW GROUND ROD CONDUIT HEIGHT 0.5"-3.5" SCALE:1/8"=V-0" nT C3D xrt TIaDCE PV MODULES T SLOPE nr LED xrc Maroc WW BOLT CLIP./1 B0.T AM I=BASM AND UU Ml n SOLNt AV1K RENEWABLE 90170M MOUNTING CLIP ENERGY PROVIDER INC 3OW 12TH STREET. RNERSIDE G WWT TILT iro Mr EvW w ro� TEL:(95.300 N QI I�1N FAX:(951)213 M Lp-�1t0T BM.Bf.xT CLASS IF C46 LK:A MM Q1RAT llE » BI IINR ITW MI Ni BORIW MATENK M'KYN w ®f OxMM�i I lam[ BBII.I lle�1�3.Q�,,IY1 R BTBOm■tlEas (E]S/U'0.17iam t-ww gym.�T Wn to a�alls x311NL acaoa „" APPROXIMATELEY "T=T6m axe lx~ nT Uv STMOOFr 1 ^f_ 01f t 2-4x jr MA ue can 3'-6» L ROBERT UU e"'ID UC.HOLDER'S SIG. WHEY WILY. PASW MBI REVERSE TILT DETAIL f SCALE:1"=1'-0" c N . 359 z c!ID O 2 '� g � 0 fn QUICK HOOK STANDOFF JU'N MODULE DERGROUND 0STANDARD GALV. DERGROUNDFLASHING WITH A1N SERWCE PANELS METER EVEREST MODULE CLAMP POLYURETHANE SEALANT Q EVEREST 48 RAIL WA AC DISCONNECT EN ABM-6063 T66 9' Y O f w 7,4 lWA SOLAR LOAD ONH 0 (E)FLAT TILE o ROOFING MATERIAL O NN EH (E)5/8'PLYWOOD O E. s1a1s ROOF DECKING 2 STORY (2)4*x IV STAINLESS S1EEL ��� sA1z-zsvP DIA LAG BOLT Gp Na�RE" en AY (E)RAFTER [� " Motrtrn E,M3I THE HOOK3 Gas ,„�,�M2,3#2LL922-I STANDOFF DETAIL A EELS MORE SCALE:11/2"=11-0" ELECTRICAL ELEVATION DETAIL ,NEET SCALE:3/8"=V-0 E 6 T&W Consulting Engineers.INC DESIGN DATA 1168 N. San Gabriel Blvd.,#N Rosemead,CA 91770 1. CODE: 2013 CALIFORNIA BUILDING CODE 2014 CITY OF LOS ANGELES BUILDING CODE 2014 COUNTY OF LOS ANGELES BUILDING CODE 2. MATERIAL STRENGTH CONCRETE: Fc'=2,500 PSI @ 28 DAYS CONCRETE REBAR: ASTM A615 GRADE 40 Fy=40,000 PSI STEEL: STRUCTURAL SHAPES: ASTM A36 Fy=36 KSI TUBING: STM A500 GRADE B Fy=46 KSI PIPE: ASTM A53 TYPE E GRADE B Fy=35 KSI WOOD: DOUGLAS FIR-LARCH( 19% MAX.M.C.) JOIST&RAFTER #2 GRADE Fb= 875 PSI Fv=95 PSI E=1.6 x 1,000,000 BEAM&HEADER(4X) #1 GRADE Fb= 1,000 PSI Fv=95 PSI E=1.7 x 1,000,000 (6X) #1 GRADE Fb= 1,000 PSI Fv=85 PSI E= 1.7 x 1,000,000 POST (4X) #1 GRADE Fb=1,000 PSI Fv=95 PSI E=1.6 x 1,000,000 (6X) #1 GRADE Fb= 1,000 PSI Fv=85 PSI E= 1.7 x 1,000,000 STUD #2 GRADE Fb=675 PSI Fv=95 PSI E=1.4 x 1,000,000 SELECT STRUCTURAL(6x,LARGE)Fb= 1,450PSI Fv=95 PSI E=1.9 x 1,000,000 MASONRY: CONCRETE BLOCK ASTM C90 F�a=1500 PSI NO INSPECTION REQUIRED 3. SOIL REPORT: Y Rf fs'=1,500 PSF/OR SEE SOILS REPORT ®� t'31�x'//1 � 4. LATERAL ANALYSIS: ® . No. 35Eg3 E A. SEISMIC LOAD Exa s �o V=CSW SEE ATTACHED. B. WIND LOAD (SEWPLIFIED PROCEDURE) �rf 0 i / MAIN WIND-FORCE RESISTING SYSTEM PS =AK 1IPS30 (MINIMUM=10 psf) SLWIPLIFIED DESIGN WIND PRESSURE FOR EXPOSURE "C", I fomph h=30 FT. I=1.0 FROM FIG. 6-2 K zt =1.0 A :ADJUSTMENT FACTOR PER FIG. 6-2 COMPONENT AND CLADDING P EGATIVE-10 psi) n,1AKnlP,,,30 (MIN IUM POSITIVE+10 psf,N T&W Consulting Engineers,INC Material Weights 1168 N. San Gabriel Blvd.,#N Rosemead,CA 91770 Weight Of Materials -Roof and 'Rigid Insulation Approximate Weights of Floor Requirements Temlock (1"thick) 1.2 psf Trus Joist Products Refer to local building code for live load Cork 0.7 psf TJI 35X Joist Series 2.8 to 4.0 lbs./LF' Gold bohd 1.5 psf TJI 55 Joist Series 45 to 63 lbs./Lf.design requirements. Styrofoam 0.2 psf . Foamgfass 0.8 psf TJL,TJLX Truss 175 to 4.25 Rigid fiberglas 1.5 psf TJw 45 to 5.25 lbs./L.E . Composition Roofing 71/60 Truss 4.75 to S75 IbsJLF 2-15 lb. and 1-90 Ib. 1.7 psf Tim Truss 8 to 9 lbs./L.E ' 3-15 and 1-90 lb. 2-2 psf Roll or Batt Insulation TJH Truss 10 to 12 Ibs_ILF. 3-ply and gravel 5.6 psf Rock wool (1"thick)0.2 psf 4-ply and gravel 6.0 psf Glass wool 0 thick) 0.1 psf 5-ply and gravel 6.5 psf ALPOL 0"thick)0.1 psf Fir Framing Members IRMA (Insulated Roof Nominal Joist Spacing Membrane Assembly) 2" 13.0 psf size 12" 16, 24" Single-ply roofs (Insulation not included) 2x4 1.4 psf 1.1 psf 0.7 psf Ballasted system 13.0 psf Floors 2x6 22 psf 1.7 psi 1.1 psf Mechanically fastened 2.0 psf Hardwood(Nominal 1") 4.0 psf 2x8 29 psf 22 psf 1.5 psi Fully adhered 2.0 psf.-Concrete 0"thick): 2x10 3.7psf 2-8 psf 1.9psf Regular 12.0 psf Zd2 4.4 psf 3.3 psf 22 psf Lightweight 6.0 to 10.0 psf. 3x6 24 ptf Linoleum or soft tile 1.5 psf Fir Sheathing 4x6 5.0pff ceramic or quarry file 10.0 psf - (Based on 36 pcf) 4x8 - 6.8 pff GYP-CRETE(�� � 6.5 psf - %„plywood 1.1 psf .�- 410 8.6 plf ?<"plywood 1.5 psf %"plywood 1.8 psf 4x12 10.4ptf �44" plywood 2.3 psf Ceilings 1'%"plywood 3.4 psf Acoustical fiber tile 1.0 psf I "gypsum board 2.2 psf Weight of Sprinkler Systems 1"sheathing 2.3 psf �� S-b!d&"4O,Sid.Pipe Schedule S 0,1 in wad 2 decking 4.3 psf %"gypsum board 2.8 psf st�oi 3"decking 7.0 sf � q w '�alm °ntvdl�wetiair; P Plaster(1"thick) 8.0 psf 4"decking 9.3 Psf Metal suspension system 1 1.7 21 - (including tile) 1.8•psf Zvi' 23 3.0 - Wood suspension system 1w, 27 3.6 (including tile) 2.5 psf r' 3.7 52 2.7 Miscellaneous Decking Materials _ 3 s Poured gypsum 0"thick) 6.5 psf all 7.6's 1o.e 4.3 79 3. . Vermiculite concrete (1"thick) 2.6 psf 8.0 Corrugated galvanized steel 31.,2" 92 13.5 5.0 112 16 ga. 2.9 psf 4" 10.9 16.4 5.6 -145 20 ga. 1.8 Psf 51, 14.8 23.5 7.8 20_0 22'ga. 1.5 psf 5' 19 2 31.7 9.3 26.2 24 ga. 1.3 psf • 8" 28.6 50�16,940_1 Asphalt shingles 2.5 psf Wood shingles 2.0 psf 10 4D5 - Clay the .9.0 to 14.0 psf Note:When accumulating total dead load we strongly urge you to use a minimum of 1.5 osf for niisceuawieous•with atl deaa luaus. TRUS JOIST CORPORATION V a derision of TJ International P.O_Box 60 Boise, Idaho 83707 208/375-4450 T & W CONSULTINki t:NW VttK5x INN. 1168 N. San Gabriel Blvd., #N Job,. Rosemead, CA. 91770 By: Tel: (626)288-0708 Date: / /20 Email: twengrsll68@gmail.com Sheet#: (2013 CALIFORNIA BUILDING CODE) EXIST'G ROOF LOAD'G (AS BUILT) SOLAR PANEL D.L. SIZE: TILE ROOF'G 9.0 #/SQ.FT. / 1/2" PLYWD SHT'G 1.5 (z)2X NHSC WEIGHT: AK/ �� #/SQ.FT. D.L. = /,��� f-�® WT= 2.9 L.L. = 20.0 #/SQ.FT. (USE 3.0 4/SQ. FT.) T.L. = 35,CD AQ / No 35693 � r y Cl v OF CAO,,-� U pq7'- ,4,/ c, y S �� SECTION 3403.3 0 T&W Consulting Engineers,INC 1168 N. San Gabriel Blvd.,#N 6.5.12.2.2 Low-Rise Building Z Rosemead,CA 91770 Velocity pressure qz= .00256 Kz Kr Kd V Iw (6-15) Kn= 1.12 Kd=0.85 V= 110 Iw= 1.00 at mean roof high h= 9 EXP=C T"6-3 Kh= 0.85 Roof angle 6= 16.4 P= gh[(GCar)-(GCp)1 (6-18) qh= 25.01 Internal Pressure Coef(GCp)= ±0.18 Enclosed Building Figure 6-5 2a= 6.0 ft Figure 6-10 MWFRS Method 2 Buildin Surface Load 4 4E Direction 1 2 3 5 6 1E 2E 3E Trans GCpf 0.52 -0.69 -0.47 -0.42 -0.45 -0.45 0.78 -1.07 -0.67 0.62 Long GCpr 0.40 -0.69 -0.37 -0.29 -0.45 -0.45 0.61 -1.07 -0.53 -0.43 gh(GCpr+Gcp;) 17.42 -12.76 -7.22 -5.89 6.75 6.75 2d.02 22.26 12.34 10.96 Trans gh(GCp1-Gcp;) 8.42 -21.76 -16.22 -14.89 -15.76 -15.76 15.01 -31.27 21.34 19.96 gh(GCpr+Gc ) 14.51 -12.76 -4.75 -2.75 -6.75 -6.75 19.76 I -22.26 -8.75 6.25 Long gh(GCpt-G 5.50 -21.76 -13.76 -11.76 -15.76 -15.76 10.76 -31.27 17.76 -15.26 Cpi) 6.5.12ACOMPONENTS AND CLADDING 6.5.12AA Low-rise building and building with h 5 60ft Velocity pressure qz= .00256 KZ Kz,Kd V2 Iw (6-15) Kn= 1.12 Kd=0.85 V= 110 Iw= 1.00 qz= 29.43 Kz at mean roof high h= 9.0 ft OK Kh= 0.85 Exp=C velocity at mean roof height,qh= 25.01 P= gh(GCp-Gco) (6-22) External pressure,+GCp= " -GCp=-1.1 Figure 6.11 through 6-16 Internal pressure,Gp;= ±0.18 Enclosed Building Figure 6-5 p= 25.01[1-(±0.16)1 Psf 25.01[-1.1-(±0.18)] Psf p= 29.51 psf psf -32.01 Psf psf 6.5.12.4.2 Building with h>60ft at mean roof high h= 9.0 ft Provision of ASCE 6.5.12.4.1 shall be used Kh= 0.85 qz= 29.43 KZ J6g� C_- r- p= q(GCp)-gj(GCpj) (6-23) n. Z= 0 Kz=0.85 cx0• 3 qh= 25.01 qz=25.01 �y External pressure,+GCp= 1 GCp=-1.1 Figure6-17 ,J'J C1v Internal pressure,Gp;= ± 0.18 Enclosed Building Figure 6-5 qTF OF A`'��` Windward wall,q= qz=25.01 q;= qh= 25A1 p= 25.01(1)-25.01(±0.18) 25.01(-1.1)-25.01(±0.18) = 25.01 ±4.50 psf -27.51 ±4.50 psf = 29.51 psf -32.01 psf Leeward wall,side wall and roof evaluated at height h q= qh=25.01 qi= qh=- 25.01 =25.01(1)-25.01(±0.18) 25.01(-1.1)-25.01(±0.18) = 25.01 ±4.50 psf -27.51 ±4.50 psf = 29.51 psf -32.01. psf 6.5.15,Design Wind Load on Others Structures F= qzG CfAf (6-27) qZ .00256 KZ Kn Kd V21 (6-15) Ht.z at the centroid of area Al= 9 ft Exp=c Exposure coefficient Kz= 0.85 6.5.6.6,T-6-3 for MWFR Topography factor Kn= 1.00 6.5.7.2 Directionality factor Kd= 0.85 Table 6-4 Wind Speed V= 110 mph Importance factor Iw= 1.00 Table 6-1 qz=22.38 psf Gust Effect factor G= 0.85 6.5.8 Force coeff Ci= 1.31 Figure 6-21 through 6-23 Design wind pressure,F/Ar =24.92 psf T&W Consulting Engineers 111C 1168 N.San Gabriel Blvd.,#N Rosemead,CA 91770 _Wnc: rssu Pner= 1 x K,t x / x PneW 1;0 1.0 1.0 ^F" . Ex ure B a_ 3. Ft ''`*Min. Figure 6-3: Roof Slope= -27 de Page 42.} v $�26 a 7 t A BA= area of ew el. Using 3 :99 x 65.43"/1-04} ;,Tq•~g.i. :f.f .;'C'- o.nc ";f'.:U•.t.'�;.y:.�"•-'d• iftiYs'�'.�'..e,:+;�.;.i: v.el,: '..'; '�'.i•.V: ����1',.'�.'�<' Vi.u`)�.:�?-j. _ .i;' ~�•N:3� '.:/ice -•GY`,�'.>;..- /j�/��}���� //1 (�`f�G�y�/ .! .RL( .�t ,.r .H.. ,t'L'.i-::�'ii mil - .F.:)v✓":.i i1�J' _.rA!r- ._''✓ _ L'v�.i ly�� J _� '�i.. .Jl•> _ :.^`%w�':r�:':-.S.c '�r4..- - 'r'l.�.C'.'ra''r?:•:i�.`! .,:'cvJc .�,`�Y,^��i s7r� {�}c�,�-.•.�r/J��$}'r'yF-.. 4..=GL;�:. ..r-, •'i�::_- �.<' :Y— ':.4 '� :,':'.•'+_'''r•'�w:.^. �..�3•�„r.,. ,:�+�'+fir ;�,Y r-_�� �,'r.•'�.^':'�n ,:}:r t._ Calculate W for least horizvrdal>30' App#y wind uplift design loads by roof wind zone to the rater/;truss with most stanchion s/greate--sip wind toad. plift at each. StancNon/A�nchar (*0.613L} . *Resisting DL * Pesistin:g DL Tres Uplift Reaction t Resisting DL Uplift Reaction Uplift each Stanchion/Anchor A �r Ridge Board 1 ' t � • I Uplift Reaction{ *Resisting DL *l3eSt3tlftg DL Rafters Uplift Reaction Uplift Reaction G\ES\a&S\1 PLANCHECKIForms&HandmdslPhotovoltaic on SFD Roof—Basic Submittal Requirements.doo Paga 2 of 3 JLTSNU tNbi Mr-Maz AlN5.1 1168 N. San Gabriel Blvd.,#N Job: By: Rosemead, CA. 91770 Date: / 120 Tel: (626)288-0708 Sheet#: Email:twengrs1168@gmail.com LATERAL (2013 CALIFORNIA BUILDING CODE) EXP "C", 'WIND SPEED: 110 mph. (C.B.C. SECTION 1609) UPLIFT/WITHDRAWL FORCE FOR SOLAR.PANEL STANDOFF /FASTJACK Vup= 24.92"sQ" c3� � No• 35693 Fxp.9-30 � SEISMIC PER C.B.C. SECTION 3403.4 14�f O.K. USE 5/16" 0 X 3 1/2" LONG STAINLESS STEEL LAG SCREW WITH MIN. 1 1/Z" EMBED TO EXIST'G ROOF MEMBER. CAN RESIST WIND UPLIFT FOR VALL= 274 X 1.5 = 411* > . ..Z Withdrawal resign. Values 11.2.1 Lag Screws 11:2.1.2 When lag screws are loaded in withdrawal from end grain, nominal withdrawal design;values; A; 11.2.1 1 The withdrawal design values, in.lbs./in. of shall be multiplied by the end grain factor,Ceg=0.75. penetration, for a single lag screw inserted in side grain 11.2.1.3 When lag screws are loaded in withdrawal, with the lag screw axis perpendicular to the wood fibers; the allowable tensile strength of the lag screw at the net shall be detern fined from.Table 11.2A or Equation 11.2-1, .(root)section shall not be exceeded(see 10.2.3). within the range of specific gravities and screw diameters given in Table 11.2A.Tabulated nominal design values,W, shall be multiplied by all.applicable adjustment factors(see Table 10.3.1)to obtain allowable,design values,W W=1800G312p3Y4 Table 11.2A Lag Screw Withdrawal Design Values MI Tabulated withdrawal design values(W)are in pounds per inch of thread penetration into side brain of main member. Length of thread penetration in main member shall not include the length of the tapered tip:(see Appendix L). Specific Gravity L•ag,Screw Unthreaded Shank Diameter,D G 114" 5/16" 3/9" j 7/16-T 1/2" 5/8" 3/4"` 7/8" 1" 1-I/8 1-1/4' 0:73 397 465 538 .604 668 789 905 .I IG16 1123 1226 1327 AIF- 0-7 1 381 45G 516 579 640 75.7 969 . 974 1071 .1176 1.273 ~' 168 357 422 484 543 600 709 813. 913 1009 1103 .1I93 6.67. 349 413 473 531 581 694 796 893 f 987 108 1167 158 .281 332 381 428 473 559 641 719 795 869 940 0.55 260. 307 352 395 43_7 516 592. 664 734 .802 869 0.51 282 274 314 353 390 461 528: 593 656 716 775 0,50 �`: 225 266 305 342 578 441 513 576 636 695 752. 0:.49 218 258 296 3.32 367 434 498 559 617 674 730 0.47 -205 242 278 312 345 408 467 525 580 634 68.6 0.46 199 235 269 302 334 395 453 508' 562 613 664 0.44 I86 220 252 283 312 369 423 475 525 574 621 0.43 T79 212 243 273 302 357 40..9 459 508 554' 600 0.42 173 205 235 264 291 3.44 395 443 490 535 579 0.41 167 198 226 254 281 332 381 428 473 516 559 0-40 161 190 218 245 271. 320 367 412 .455 497 538 039 155 183 2:10 236 261 308 353 397 438 479 518 0.38 149 176 202 227 251 296 340 381 422 461 498 0.37 143 169, 194 218 24.1 285 326 367 405 443 479 0.36 137 163 186 209 231 273 313 352 389 425 460 0.35 132 156 1.79 200 222 262 300 337 373 407 441 0.31 110 1 130 1:49 1.67 185 218 250 281 1 311 1 3.39 1 367 1.Tabulated withdrawal desiger.values(W)for lag screw connections shall be multiplied by all applicable adjustment factors(see Table 10.3.1)_ J3. AMEERlcAh WOOD COjW-IL So/ar JAROLD SMOLLEN 8.25 kW (DC) PHOTOVOLTAIC SYSTEM CITY OF LAKE ELSINORSOLAR MAX RENEWABLE ENERGY PROVIDER INC 15036 VISTA VIEW, LAKE ELSINORE, CA. 92530 TEL: (9THST-0788 RIVERSIDE,CA 92507 TEE: (951)300-0788 iviSION FAX: (951)213.3099 CLASS#C 46 LIC#972048 CONFIDEIAL GENERAL NOTES: SOLAR PHOTOVOLTAIC SYSTEM NOTES: ABBREVIATIONS USED ITHE THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARMAX RENEWABLE All materials,equipment,installation and work shall comply with the following 20.All the NEC required warning signs, markings,and labels shall A !CONCRETE ERE _ ENERGY ISCLOSED INC,NOR ORIEL IT BE DISCLOSED RI WHOLE OR IN HE applicable codes: be posted on equipment and disconnects prior to any insp PARTS OTHERS TION,OUTSIDE 7EP NOTE: RNATING CURRENT awENrs ORGANIZATION,EXCEPT M • 2013 CBC/2012 IBC to be performed by the Building Department inspector. rEiR10JIT 0 CONNECOr TION S D USE RESPECTIVE SOLARMAX 1. All smoke alarms, Carbon monoxide alarms and 2013 CRC/2012 IRC 21. Metallic raceways or metallic enclosures are required wiring BLDG DING EQUIPMENT,ON OF THE WRITTEN RMAX audible notification devices shall be listed and 2013 CEC/2011 NEC method for inside a building for PV system. [NEC 690.31(E)] PERMISSION of soL MDER • 2013 CMC/2012 UMC 22.Flexible,fine-stranded cables shall be terminated only with CONC NEWABIE ERGY PRONDER INC. labeled in accordance with UL 217 and UL 2034. 2013 CPC/2012 UPC terminals,lugs,devices or connector that are identified an They will be installed in accordance with NFPA 72 2013 CFC/2012 IFC for such use.[NEC 690.31(F)] C I ---U and NFPA 720. (CRC 2013 R314 &R315). 2008/2013 Building Energy Efficiency Standards 23.Connectors shall be of latching or locking type.Connectors C ROBERT 'S • Authority Having Jurisdiction- LAKE ELSINORE that are readily accessible and operating at over 30 volts shall %PD TRI UTION PANEL LIC. HOLDERS SIG. 2. 2013 California Residential Code (CRC) requires 24.Require tool to open and marked"Do Not Disconnect Under DC DIRECT CURRENT that Smoke alarms and Carbon Monoxide Alarms be 1. Existing plumbing vents,skylights,exhaust outlets,ventilations intake air Load"or"Not For Current Interrupting". [NEC 690.33(C)&(E)(2)] EGC EQUIPMENT GROUNDING CONDUCTOR retrofitted into the existing dwelling. These Smoke openings shall not be covered by the solar photovoltaic system. 25. Equipment grounding conductor for PV modules smaller than (E) (EXISTING) 2. Equipment.Inverters,motor generators,photovoltaic 6AWG shall be protected from physical damage by a raceway or FV FIELD VERIFIED alarms are required to be in all bedrooms, outside modules,photovoltaic panels,ac photovoltaic modules, Cable armor. [NEC 690.46&250.120(C)] each bedroom, and at least one on each floor of the source-circuit combiners,and charge controllers intended 26 uipment grounding conductor for PV systems without GEC GALVANIZED for use in photovoltaic power systems shall be identified Fault Protection(GFP)and installed on non-dwelling unit GEC GROUNDING ELECTRODE CONDUCTOR house. Carbon Monoxide alarms are required to be and listed for the application. (NEC 690.4(D)) mus mpacity of at least 2 times the temperature and GND GROUND retrofitted outside each bedroom and at least one on 3.All outdoor equipment shall be NEMA 3R rated,including all roof mounted co�dult Cected circuit conductor ampacity. [NEC 690.45(B)] HDG HOT DIPPED GALVANIZED each floor of the house. These alarms may be solely transition boxes and switches. 2 e s ded cables used for battery terminals,devices,and I CURRENT 3 z 4.All equipment shall be properly grounded and bonded in accordance with NEC c s require lugs and terminals listed and marked for the Imp CURRENT AT MAX POWER N obattery operated if the Photovoltaic project does not article 250. u!:1 690.74] INVT INVERTER c6 o J co involve the removal of interior wall and ceiling 5.All circuits connected to more than one source shall have overcurrent devices Isc SHORT CIRCUIT CURRENT UJ U, J rn located so as to provide overcurrent protection from all sources. [NEC 690.9(A)] SHEET INDEX: k KILOVOLT AMPERE N; O N w Q finishes inside the home, otherwise, the alarms must 6.All photovoltaic(PV)modules shall be mounted on the roof.Additional e; � -1 KILOWATT W 2 o > v be hard wired and interconnected. equipment of the PV system shall be located outside the building near the main E1 - COVER C �°' LOAD BEARING WALL U It Q W electrical services. [NEC 690.14(C)] E2 - SITE P [ " \ � MINIMUM 0o U) N S2 O 7.The utility interactive inverters shall automatically de-energize its output to � � M� W o M> Z the connected electrical production and distribution network upon loss of E3 - NOT US >MCB MAIN CIRCUIT BREAKER °o Q D. o J SCOPE OF WORK: voltage in the system and shall remain in that state until the electrical E4 - NOT USED AIN SERVICE PANEL W W J �-0 w production and distribution network voltage has been restored.[NEC 690.61] �,N � - - -+ "" N ° O `n INSTALL 33 NEW SMX-250P SOLAR PANELS 8. Due to the fact that PV modules are energized whenever exposed to light,PV E5 - ROOF i - (R'� NEM ) 3R, RAINTIGHT OUTSIDE RATED ° Y INSTALL 33 NEW ENPHASE M-215-60-2LL-S22-IG contractor shall disable the array during E6 - DETAILS _ ZONAL ELECTRICAL CODE installation and service by short circuiting,open circuiting,or covering the array E7 - SINGLETS_.-__....r_____--- -�--- NTS NOT TO SCALE INSTALL J-BOXES,COMBINER BOX, RACEWAYS AND WIRING with opaque covering.[NEC 690.18] E7.1 - SINGLE LINES NOTES OC ON CENTER INSTALL 60A AC DISCONNECT 9.All conductor exposed to weather shall be listed and identified for use in OCPD OVERCURRENT PROTECTION DEVICE direct sunlight.[NEC 690.31(B),310.8(D)] E8 - NOT USED p POLES -BREAKER POLES- INSTALL 40A 2 POLE PV BREAKER 10.The module conductors must be type USE-2 or listed for photovoltaic(PV) E9 - SIGNAGE INSTALL NEW 200A/200A TOP FED MAIN SERVICE PANEL wire.(NEC 690.31(B)) PL PROPERTY LINES ' TOTAL SYSTEM SIZE 8.25 kW DC 11.All conductors shall be marked on each end for unique identification. E1 O - PV CUT SHEETS PV PHOTOVOLTAIC 9 f ( ) 12. PV module negative shall be grounded.All grounded conductor shall be Ell - INVERTER CUT SHEETS PVC POLYVINYL CHLORIDE properly color identified as white. [NEC 200.61 RR ROOF RAFTER E12 - ELECTRICAL CUT SHEETS 13. PV system connected on the load side of the service disconnecting means of SBC SOLID BARE COPPER a '� VICINITY MAP the other source(s)at any distribution equipment on the premises shall meet E13 - ELECTRICAL CUT SHEETS Sp SOLAR PLANE the following[NEC 705.12(D)]: ;y E14 - ELECTRICAL CUT SHEETS SPL SUBPANEL gRAWN65; 14. Each source connection shall be made at a dedicated circuit breaker or E15 - ELECTRICAL CUT SHEETS SCH SCHEDULEDATE: fusible disconnecting means. [NEC 705.12(D)(1)] SS STAINLESS STEELRESa 15.The sum of the ampere rating of the overcurrent devices in circuits E16 - ELECTRICAL CUT SHEETS PTC PRACTICAL TESTING CONDITIONS 4MA supplying power to the busbar or conductor shall not exceed 120%of the rating E17 - ELECTRICAL CUT SHEETS SWH SOLAR WATER HEATER T of busbar or conductor. [NEC 705.12(D)(2)] E18 - ELECTRICAL CUT SHEETS TYP TYPICAL SMX-250P 16.The interconnection point shall be on the line side of all ground-faultkW protection equipment.[NEC 705.12(D)(3)] E19 - ELECTRICAL CUT SHEETS UNO UNLESS NOTED OTHERWISE STEM kW: 8 V VOLT MOUNTING MSI TILEILE HOOKS HOOKS 17. Equipment containing overcurrent devices in circuits supplying power to a E20 - ELECTRICAL CUT SHEETS Vmp VOLTAGE AT MAX POWER HARDWARE: bus bar or conductor shall be marked to M215.60.2LL-S22-I E21 - ELECTRICAL CUT SHEETS indicate the presence of all sources. [NEC 705.12(D)(4)] Voc VOLTAGE AT OPEN CIRCUIT INVERTER: 18.Circuit breaker,if backfed,shall be suitable for such operation. [NEC E22 - ELECTRICAL CUT SHEETS W WATT AHJ: LAKE ELSINORE 705.12(D)(5)] E23 - ELECTRICAL CUT SHEETS * OCCUPANCY TYPE: R-3 SHEET NUMBER: 19.To minimize overheating of the busbar in panelboard,the panelboard main El circuit breaker and the PV power source circuit breaker shall be physically E24 - ELECTRICAL CUT SHEETS * CONSTRUCTION TYPE: TYPE V-B NTS located at the opposite end of the busbar. E25 - ELECTRICAL CUT SHEETS * UNSPRINKLERED SP1 NEW 20OA/200A TOP FED So/ar`,' PITCH: 190 SERVICE POINT & UTILITY METERING /UI14X', AZIMUTH: 1701 (N) 60A AC DISCONNECT SOLAR MAX RENEWABLE MATERIAL: FLAT CEMENT (N) 100A SOLAR STORIES: 2 LOAD CENTER \ aw ENERGY SIDE,CA C(�CT \ Q,�d RIVERSIDE,CA 92507 0788 SP SQ.I I: 891.67 01 6'W x 42"D x 6'-6"H WORK TEL: (951)213-3099 4'-9"W x 42"D x 6'-6"H WORK FAX: C46LIC#972 ARRAY SQ.FT: 376.18 CLEARANCE PER NEC CLASS#C45LIC#972048 ON CLEARANCE PER NEC 110.26(A)(1)f HEREINCONL-1NSHALL NOT 110.26 A 1 110,26(A)(2) IiED F R THE BEN SHALL NOT BE SP2 110.26(A)(2) 8c 110.26(A)(3) USED FOR THE RMAX R NE ANYONE ( f EXCEPT SOLARMAX RENEWABLE & 110.26(A)(3) ENERGY ISCLOPROVIDER IN WHOLE C.,NOR SH IN ALL PITCH: 19° NEW PV CONDUIT TO BE RUN WITHIN EVE ITBEDISCORGANINION,ECRT PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION,EXCEPT IN CONNECTION WITH THE SALE AND USE AZIMUTH: 1701 AND HIDDEN FROM VIEW. CONDUIT TO BE OF THE RESPECTIVE X EQUIPMENT,WITHOUT THE HE WPo7 WRIT7EN MAX MATERIAL: FLAT CEMENT PAINTED TO MATCH EXISTING SURFACE. PERMISSION DER RENEWABLE ENERGY PROVIDER INC. STORIES: 2 SP SQ.FT: 270.43 Front 03 0 Residence 6 VISTA VIEW ROBERT LIU ARRAY SQ.FT: 107.45 AZIMUTH: 1700 LIC. HOLDER'S SIG. PITCH: 50 "\rR�S CONDUIT TO BE SP3 5' REVERSE TILT @T�\k RUN IN ATTIC PITCH: 190 AZIMUTH: 3501 O MATERIAL: FLAT CEMENT STORIES: 2 \ ' SP SQ.FT: 553.30 \ z LLI ARRAY SQ.FT: 107.45 \ FIRS ACR I�� 3 oM ®� 3 FIB qc .2 —� 0. EQUIPMENT LEGEND \\ �, o W O N W (N) (E) DISCRIPTION \ �' ® 0 \ FQ � ¢ LLi MP MP MAIN SERVICE PANEL w/ WARNING LABEL S��BPCR �g ° 4 \\ ® O �' > z M 3 FIB S�TBP 8 0 0 0 t o w E O O DEDICATED PV SYSTEM METER �� FIR W�\\ \ �11p� a o 0 Lo Y O O INVERTER w/ WARNING LABEL �� \\ SO \�T&yc Q (BUILT-IN DC DISCO) O ® DP oP DISTRIBUTION PANEL w/ WARNING LABEL O O SS � �� 0 Lc �c LOAD CENTER w/ WARNING LABEL v ® © \ �' ® \ .w O oco oco DC DISCONNECT w/ WARNING LABEL \ a ' D Aw AC DISCONNECT w/ WARNING LABEL ® \ DRAWN AC Er © IIAr 1 `..5-14-14 JH 0UNCTION BOX ESIDENTIAL BUI�DI Hi: 2 STORY cH cH DC COMBINER BOX w/ WARNING LABEL MOZEM ES: SMX-250P BY kV: 8.25 kW AL ACCESS LADDER MOUNTING MSI TILE HOOKS SITE PLAN HARDWARE INVERTER: M215.50.2LL-$22-IG EXTERIOR CONDUIT RUN SCALE: 1/8" = V-0" AHD: LAKE ELSINORE ------ INTERIOR CONDUIT RUN TOTAL ROOF SQ.FT: 2389.95 SHEET NUMBER: INTERIOR EQUIPMENT TOTAL ARRAY SQ.FT: 591.08 E2 --o-- FENCE ARRAY COVERAGE: 25% 01 00 SP# 1 Solar`�� V MODULES (21)SMX-250P A /; MOUNTING EQUIP. MSI TILE HOOKS 11P S RACKING SYSTEM EVEREST RAIL SOLAR MAX RENEWABLE / � � \ ENERGY PROVIDER INC PV SYSTEM HEIGHT 9" o�d dw 4 RIVERSIDE,CA9 507 PITCH 190 13A FAX: (951)213 3099 AZIMUTH 170° CLASS#C-46 LIC#972048 CWFlDENIIAL-THE INFORMATION MATERIAL FALT CEMENT HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFlT W ANYONE STORIES 2 EXCEPT SOLARMAXDER IN RENEWABLE ENERGY PROVIDER INC.,NCR SHALL (1 IT BE DISCLOSED IN WHOLE OR IN SP SQ.FT $91.67 PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION,EXCEPT IN ARRAY SQ.FT 376.18 CONOf T ENREES ECTIVE SSaARRMMAAXUSE RITTEN ARRAY /0 42/0 0 „ EQUIPMENT,WITHOUT THE MAX 0 0 5 PERMISSION OF soLARMAx AZIMUTH: 170 RENEWABLE ENERGY PRONDER INC. RAFTER SIZE 2"X 4"TRUSS PITCH: 5° Front Of Residence RAFTER SPACING 24"OC MEAN ROOF HEIGHT 24' 5° REVERSE TILT 11„ MPX 15036 VISTA VIEW RO 717- 16' LIC. HOLDER'S SIG. SP# 2 ?\5�� PV MODULES (6)SMX-250P 1�,2' � \, LATERAL POINT LOAD MOUNTING EQUIP. MSI TILE HOOKS RACKING SYSTEM EVEREST RAIL PV SYSTEM HEIGHT 9 PITCH 190 � ' � �'` '"" �1 z AZIMUTH 1700 `�- ��$Nc23 � 8-,� w MATERIAL FALT CEMENT \` ,�1RES EEC ` \1 a O LO STORIES 2 \' �, �k w J " �, ,�.�, Wn 0 N w Q SP SQ.FT 270.43 \', �,� ' �,6 �> o ARRAY SQ.FT 107.45 \ \'`, " `' Q a Lu W~ (l) U) ARRAY% 39% ;���g,AC� v,`\ 'o �' > z RAFTER SIZE 2"X 4"TRUSS `p' 3 F S T$ c� �� \ o. 0 o J RAFTER SPACING 24 OC a\`';3 Fl ��\ \ r8, a� 0 U) w MEAN ROOF HEIGHT 24'01 MY` �9 N J SP# 3 PV MODULES (6)SMX-250P `, MPX MOUNTING EQUIP. MSI TILE HOOKS RACKING SYSTEM EVEREST RAIL /i[ PV SYSTEM HEIGHT 6"-APPROX. 2'-10" PITCH 19 7 rn`` \, r ., (( •yF r n. AZIMUTH 3500 v .•Y ' \;'' '`,` �- ¢ < rR MATERIAL FALT CEMENT `, r \,`�` �-. OR'A1NN Y STORIES 2 A E 5,a 14d SP SQ.FT 553.30 X ARRAY SQ.FT 107.45 �, IL NG HT: 2 STORY ARRAY% 19% M ULES: SMX-250P RAFTER SIZE 2"X 4"TRUSS , d, STEM kV: 8.25 kW RAFTER SPACING 24"OC MOUNTING HARDWARE: MSI TILE HOOKS MEAN ROOF HEIGHT 24' INVERTER: M215-60-2LL-S22-IG AHJ: LAKE ELSINORE ROOF PLAN SHEET NUMBER: GROUND METHOD NEW GROUND ROD CONDUIT IGHT 0.5"- 3.5"HE SCALE: 1/8" = 1'-0" PV MODULES 5' SLOPE TILT LEG KIT MODULE TILT LEG KIT MODULE CLAMP w/A" BOLT CLAMP w/J" BOLT AND LOCK WASHER AND LOCK WASHER SOLAR MAX RENEWABLE ENERGY PROVIDER INC 3080 12TH STREET, BOTTOM MOUNTING CLIP RIVERSIDE,CA 92507 TEL: (951)300-0788 TILT LEG KIT EVEREST 48 RAIL FAX: (951)213-3099 EN AW-6063 T66 CLASS#C-46 LIC#972048 L-FOOT BRACKET k BOLT CONFIDENTIAL-THE INFORMATION 6 TT (3/8'X 3/4'5 HEREIN CONTAINED SHALL NOT BE (E)FLAT TILE w/FLANGE NUT(3/8) USED FOR THE BENEFIT OF ANYONE ROOFING MATERIAL (3/8'X 3/4')BOLT EXCEPT SOLARMAX RENEWABLE ENERGY PROVIDER INC.,NCR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE (E)5/8`PLYWOOD L-FOOT BRACKET A BOLT ROOF DECKING��\\ (3/8'X 3/4') CONNECTION RECIPIENTS THE SALE AND USE w/FLANGE NUT(3/B) A P P R O X I M A T E L E Y OF NNE RESPECTIVE ME WRITTEN 18O EQUIPMENT,WITON OF THE WRITTEN TILT LEG STANDOFF 2'-10" PERMISSION EN, RENEWABLE ENERGY PRONDER INC. 3 -6 2-4'X " DIA LAG BOLTS ROBERT LIU (E)RAFTER LIC. HOLDER'S SIG. OATEY GALV. FLASHING NTH POLYURETHANE SEALANT REVERSE TILT DETAIL ` SCALE, 1 — 1 0 ' (, :s O I cq L N 0 N 9 W W; O 04Lu NN o U � QLL ff .mow' w t— ' ) Lo F- 1 (0 O OV U) O 00 MtZ / Y (o Dow QUICK HOOK STANDOFF NEW 200A/200A TOP FEDMAIN BREAKER EXISTING GATN a O O Y 120/240V 1¢3W (n MODULE STANDARD GALV. UNDERGROUND FLASHING WITH MAIN SERVICE PANEL&METER EVEREST MODULE CLAMP POLYURETHANE SEALANT J NEW EVEREST 48 RAIL »" ; 60A AC DISCONNECT t U � EN AW-6063 T66 O r'1LLJ qq nEw 9�� � 4" f 100A SOLAR LOAD CENTER t a' (E) FLAT TILE �] °R"WN E" 777 f ROOFING MATERIAL 3{ / O DATE 5-14-ra MRESIDENTIAL (E) 5/8 PLYWOOD DI G H ROOF DECKING 2 sTORv • -- T (2) 4% STAINLESS STEEL __ MG LES: SMX-250P DIA LAG BOLT Comm S STEM kV: 8.25 kW MOUNTING (E) RAFTER HARDWARE: MSI TILE HOOKS Gas INVERTER: M215-60-2LL-S22-IG STANDOFFDETAIL A J: LAKE ELSINORE SCALE: 11/2" = 1'-0" ELECTRICAL ELEVATION DETAIL SHEET NUMBER: SCALE: 3/8" = 1'-0' E6__,,j; SERVICE INFO 01 INVERTER SPECS MODULE SPECS AMBIENT TEMPERATURE SPECS A] 2-NEW COOPER PASS THROUGH BOXES Solar UTILITY COMPANY: INVERTER TYPE: QTY: 33 AVG. AMBIENT TEMP: 99° F - ,; MAIN SERVICE VOLTAGE: 240V ENP M125-60-2LL-S22-IG MODULE TYPE: SMX-250P RECORD LOW: 100 F QTY: 33 � 1-NEW 100A SOLAR ONLY LOAD CENTERSOLAR MAX RENEWABLE MAIN PANEL BRAND: NEW PANEL UPGRADE WATTAGE: 215 WATTAGE: 250W CONDUIT HEIGHT: 0.5" -3.5" 2-NEW 15A 2P/2S PV BREAKER ENERGY PROVIDER INC 0 1-NEW 15A 1 P 11 S MONITORING OUTLET3080 12TH STREET, MAIN SERVICE PANEL RATING: NEW 200A SERVICE VOLTAGE: 240 NOCT WATTAGE: 226.4W ROOF TOP ADDER: 40 F RIVERSIDE, 00-078 7 oJFC 1-NEW 60A AC DISCONNECT TEL: (951)300.0788 13-3099 MAIN CIRCUIT BREAKER RATING: NEW 200A TOP FED CEC EFFICIENCY: 96.5% FRAME THICKNESS: 40MM ROOF TOP TEMP: 139 - FAX: (951) IC#972FRAME COLOR: BLACK CONDUCTOR TEMP RATE: 90° CLASS#C-46 LIC#972048 MAIN SERVICE LOCATION: NORTH EAST BY GARAGE HEREIN CONTNIAL I THE INFORMATION VoC: 37,91V TEMP CORRECTION: 0.71 HEREIN F CONTAINED SHALL NOT BE SERVICE FEED TYPE: UNDERGROUND MP 1-NEW 40A 2P 12S PV BREAKER USED FOR THE RMAX R OF ANYONE PER 310.15(B)(2)(a) EXCEPT SOLARMAX RENEWABLE MAIN SERVICE PANEL GROUND: NEW GROUND ROD Vpmax: 30.11V 1_NEW GROUND ROD ENERGY ISCLOSER INC.,NCR SHALL IT BE DISCLOSED IN WNOLE OR IN ISC: 8.84A RECIPIENT'S TO OTHERS OUTSIDE THE ORGANIZATION,EXCEPT IN CONNECTION WITH 1HE SALE AND USE OF THE SOLARMAX Imp: 8.30A EQUIPMENT,ESPECTIVE WITHOUT THE WRITTEN PERMISSION OF SOLARMAX NEW 200A TOP FED 100A SOLAR ONLY COOPER RENEWABLE ENERGY PROVIDER INC. MAIN SERVICE PANEL 60A SQUARE-D LOAD CENTER (1)3/4" EMT PASS THROUGH AC DISCONNECT NEMA-3R CONDUIT KIT 600V NEMA-4X ROBE LIU M NEW 200A 240V NEMA-3R A 1 LIC. HOLDER'S SIG. !T 3 B / 2 (E) C 3 15A 2P L) LI LOADS �i L2 L2 1 Strings)of 11 • N N on SP 1 EGC/GEC EGC 1 GND i w GEC MODULES GROUNDED z WITH WEEBS (CONDUIT EMT ���� fg..� COOPER z N '` z PASS THROUGH W o 600V NEMA-4X J LO Y o6g j 0) EGC/GEC ®3 1 15A/2P 2 A 1 U, O N W U L) L) L,- (N)40A/2P � `, 1a L2 1 String(s)of 11 W d < /� z z I A1 ` N N onSP1&SP2 �O N O TO 120/240V //vim e �' �� C I EGC/GEC EGC p M> Z 1P 3W ?' e t. ; .R,€ ' wo o� CQ J UTILITY SERVICE GEC ?�`'� GEC o a J o W MODULES GROUNDED 11.� LO WITH WEEBS W o O Y (N) GROUND ROD fy _ COOPER Q NOTES: PASS THROUGH -7 1) All modules will be grounded in accordance with 600V NEMA-4X code and the manufacturer's installation A instructions. 120% RULE 15A/2P 2 L1 2) All pv equipment shall be listed by a recognized NEW BUS BAR RATING;200A L2 L2 1 String(s)of 11 W tested lab. NEW MAIN BREAKER RATING: 200A EGc/GEC >cc on SP 2&SP 3 W 3) Notify serving utility before activation of pv system. (200A x 1.2)-200A=40A 4) When a backfed breaker is the method of utility 40A MAX BACK FEED GEC MODULES GROUNDED DRAWN BY:PROPOSED PV SYSTEM:40A EH interconnection,breaker shall not read line and load. WTH WEEBS DATE:40A=40A 5.14-14 5) When a backfed breaker is the method of utility MARKET: RESIDENTIAL interconnection, the breaker shall be installed at the MONITORING 2 STORY OUTLET BUILDING HT: opposite end of the bus bar of the Main Breaker. 15A/1P MODULES: SMX-250P 6) Work clearances around electrical equipment will ,, PLEASE SEE SHEET E 7. 1 SYSTEM kv: 8.25 kW be maintained per NEC 110.26(a)(1), 110.26(a)(2) FOR SINGLE LINE NOTES MOUNTING & 110.26(a)(3) HARDWARE: MSI TILE HOOKS INVERTER: M215-60-2LL-S22-IG 7) All exterior conduits, fittings and boxes shall be AHJ: LAKE ELSINORE rain-tight and approved for use in wet locations per SHEET NUMBER: NEC 314.15. 8) All metallic raceways and equipment shall be E 7 bonded and electrically continuous. Solar,�. MAX SOLAR MAX RENEWABLE ENERGY PROVIDER INC 3080 12TH STREET, RIVERSIDE,CA 92507 TEL: (951)300-0788 FAX: (951)213-3099 CLASS#C-46 LIC#972048 CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARMAX RENEWABLE ENERGY PROVIDER INC.,NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION,EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARMAX SINGLE LINE NOTES EQUIPMENT,WITHOUT THE WRITTEN PERMISSION OF SOLARMAX RENEWABLE ENERGY PROVIDER INC. ROBERT LIU LIC. HOLDER'S SIG. 01 O O O Z 3 #12 PV WIRE N o J LO co 04 3 #8 THWN-2 3 #10 THWN-2 1 #12 SBC EGC °W J � 1 #6 THWN-2 EGGGEC 1 #6 THWN-2 EGCIGEC 1 #6 SBC GEC N Q I w U cc > Voc: 240 VAC Voc: 240 VAC Voc: 240 VAC W G 4 Isc: 29.7 AAC Isc: 9.9 AAC Isc: 9.9 AAC °a, `„ z ENPHASE INVERTER STRING CALCS ENPHASE INVERTER STRING CALCS ENPHASE INVERTER STRING CALCS co W° r_� IL X _! U w Og w QTY: 11 QTY: 11 MAX AC: 12.38A 0-0 Q QTY: 33 MAX AC: 37.13A MAX AC: 12.38A NOC: 0.9 (QTY x NOC)x 1.25 NOC: 0.9 (QTY x NOC)x 1.25 io NOC: 0.9 (QTY x NOC)x 1.25% Q WIRE GAUGE: #8 WIRE OCP: 39.05A WIRE GAUGE: #10 WIRE OCP: 28.4A WIRE GAUGE: #12 WIRE OCP: 21,3A TEMP RATING: 900 C AMP RATING x TEMP DE•RATE TEMP RATING: 900 C AMP RATING x TEMP DE-RATE TEMP RATING: 900 C AMP RATING x TEMP DE-RATE AMP RATING: 55A MAX AC TO BE LESS OR EQUAL TO AMP RATING: 40A MAX AC TO BE LESS OR EQUAL TO AMP RATING: 30A MAX AC TO BE LESS OR EQUAL TO WIRE OCP FOR WIRE TO BE WIRE OCP FOR WIRE TO BE WIRE OCP FOR WIRE TO BE (� TEMP DE—RATE:0.71° F APPROVED BY 2011 NEC TEMP DE—RATE:0.710 F APPROVED BY 2011 NEC TEMP DE-RATE:0.710 F APPROVED BY 2011 NEC w 0 w 11 DRAWN BY: EH DATE: 5-14-14 MARKET: RESIDENTIAL BUILDING HT: 2 STORY MODULES: SMX-250P SYSTEM kV: 8.25 kW MOUNTING HARDWARE: MSI TILE HOOKS INVERTER: M215-60-2LL-S22-IG AHJ: LAKE ELSINORE SHEET NUMBER: E7ml So/ar ;, /NIr4X CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED WARNING! INVERTER OUTPUT CONNECTION SOLAR N RENEWABLE LABEL FOR MAIN SERVICE DO NOT RELOCATE THIS ENERGY PROVIDER INC 3080 12TH STREET, OVERCURRENT DEVICE RIVERSIDE,CA92507 TEL: (951)300-0788 JI PHOTOVOLTAIC POWER SOURCE LABEL FOR MAIN SERVICE FAX: C46LC#979 CLASS#C-46 LIC#972048 CONROENTIAL—THE INFORMATION HEREIN CONTAINED SHALL NOT BE OPERATING AC VOLTAGE: 240 V CAUTION USED FOR THE BENMT OF ANYONE EXCEPT SOLARMAX RENEWABLE GY PROVIDER INC.,NOR SH MAXIMUM OPERATING AC OUTPUT WARNING! ITERE DISCLOSED IN WHOLE OR IN POWER TO THIS BUILDING IS ALSOPART TO OTHERS OUTSIDE THE CURRENT: 37.13 AMPS ELECTRIC SHOCK HAZARD. RECIPIENT'S ORGANIZATION,EXCEPT IN ANO USE DO NOT TOUCH TERMINALS. SUPPLIED FROM THE FOLLOWING EQUIPMNT,WNNECTION HTHESAEE WRITTEN OF THE RESPECTIVE SOLARMAX LABEL FOR MAIN SERVICE PANEL COVER EQUIPMENT,ION Of THE WRITTEN PERMISSION OF$CLARMAX TERMINALS ON BOTH THE LINE AND SOURCES WITH DISCONNECTS RENEWABLE ENERGY PROVIDER INC. LOAD SIDES MAY BE ENERGIZED U�:� PHOTOVOLTAIC ARRAY IN THE OPEN POSITION. LOCATED AS SHOWN. ROBERT LIU AC DISCONNECT OPERATING CURRENT: 37.13 A LABEL FOR COMBINER BOX LIC. HOLDER'S SIG. SERVICE POINT& OPERATING VOLTAGE: 240 V UTILITY METERING LABEL FOR AC DISCONNECT CAUTION: SOLAR CIRCUIT (N)AC DISCONNECT (N)100A SOLAR LABEL FOR ALL CONDUIT,RACEWAYS, LOAD CENTER ENCLOSURES,CABLE ASSEMBLIES&J-BOXES FRONT WARNING! OF HOME z ELECTRIC SHOCK HAZARD. PHOTOVOLTAIC DISCONNECT DO NOT TOUCH TERMINALS. PHOT 3 W M TERMINALS ON BOTH THE LINE AND FOR UTILITY OPERATIONS "'� J W � LOAD SIDES MAY BE ENERGIZED LABEL FOR AC DISCONNECT N N IN THE OPEN POSITION. co 2 n 0 O LABEL FOR AC DISCONNECT N o YJ C'J U) O WARNING! W° r M J THIS SERVICE ALSO SERVED (N)SOLAR ARRAY o a.w J --� w 0g w BY A PHOTOVOLTAIC SYSTEM a o 0 a LABEL FOR MAIN SERVICE PANEL Q CAUTION: SOLAR CIRCUIT DISCONNECT LABEL FOR AC DISCONNECT w O DRAWN BY: EH Marking PV Circuit DATE: 5-14.14 MARKET: RESIDENTIAL Marking is required on all interior and exterior PV conduit, Marking Content and Format BUILDING HT: 2STORY raceways, enclosures, cable assemblies, and junction boxes to MODULES: SMX-250P alert the fire service to avoid cutting them. Marking shall be Marking Content: CAUTION: SOLAR CIRCUIT SYSTEM kV: 8.25kW placed every 10 feet, at turns and above and/or below MOUNTING MSI TILE HOOKS penetrations, and at all PV combiner and junction boxes. -Red Background HARDWARE -White Lettering INVERTER: M215-60-2LL-S22-IG Reflective weather resistant material suitable for the -Minimum 3/8" Letter Height AHJ: LAKE ELSINORE environment(durable adhesive materials must meet this -AIL capital letters SHEET NUMBER: requirement) -Arial or similar font, Non bold E 9 MAX' SOLAR MAX RENEWABLE ENERGY PROVIDER INC 3080 12TH STREET, RIVERSIDE,CA 92507 300-0788 51)213 3099 ,. PAX: (951)2 3 �(� LASS#C-46 LIC#972048 C � l � . CONFIDENTIAL -THE INFORMATION ' ; - "!'- CONTAINED SHALL NOT BE ;.� # s HEREIN CON Pa! cralllne S1a ANYONE " USED FOR THE BENEFIT OF A61 , l8a .•' ' EXCEPT SOLARMAX RENEWABLE ENERGY PROVIDER INC..NOR SHALL ,,.;.. .. _. • IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE Dim en Q $ # rim Working Con4itl6n RECIPIENTS ORGANIZATION,EXCEPT IN CONNECTION WITH THE SALE AND USE ${30 OF THE RESPECTIVE SOLARMAX Aqp _Tilsit:Inahlr;ts Maximum System Voltage(V) EQUIPMENT,WITHOUT THE WRITTEN Power Tolerance 01+3% PERMISSION OF SOLARMAX RENEWABLE DqGY PROVIDER INC High Effidency: 3B.97in Cell Dimension 156"156 mm SMX Capital has developed this high efficiency panel which delivers a _ Number of Cells/Layout sopcsrlot6 superior efficiency of 15.40% NOCT Cell ate°c ROBERT LIU to consumers worldwide. A Temperature Coefficient Isc(%) +0.040.015°1 1°C LIC. HOLDER'S SIG. Temperature Coefficient VPc(%) -O.3t0.02%1°C Temperature Coefficient Pm(%) 0.45t0.05%/'C Reliability: Temperature Coefficient lm(ok) +0.04'Yo 1'C Every module i5 equipped with 3.2 mm Temperature Coefficient Vm(%) -0.32t0.02%1°C high transmission tempered glass and a Operating Temperatures -40°C1+90'C standard waterproof junction box. surface Pressure 60 m/s.(200 kglm') Series Fuse 15 Amps Z Safety: W ��. ��r CD Bypass diodes protect the modules �> �- . z. Electrical Performani s � � r from burns caused by hot spots due to Peak Power Pmax VVp 250 226.4 �u- N shading. Maximum Power Voltage Vmp V 30,11 28.09 0 , W Q Maximum Power Current Imp A 8,30 8.37 N o > U Lightweight. SlaortCircuit Current Isc A 8.$4 {$.91 W a Anodized aluminum-alloy frame. The SMX 250 Watt Solar Module is a cost effective,high open Circuit Voltage Voc V 37.91 35.52 }o N O effedency renewable power solution. Cell Efficiency 17.12 0° 0 M Module Efficiency 15.40 0 C -0 Lu Warranty: a o O Y 25 Year Limited Power Warranty Warranty and Q 10 Year Limited Construction Warranty l-VCurve 2m Y ye J Warranty 25-5-year limited power warranty calls Temp.=25`C I 10-year limited product warranty 6 mpaara+rr&tlus,�_=I'M3 ,41m' Certifications Tested to UL 1703,Class C Fire'Rating s E i Standard Test CondIlion T 25 C AM=1.5 E=1,000 WAn' inckferl 6R�ks�r.= fiG0YJ1 m' .N a Mechanical l3afu s 8m . mcmc t trraaie-,ce=soave I m' _ 113 f 550 m' 5400 Pal),front e, snow U Max Load ps k91 { { 9. ) Lu 50 sf 245 k 1m e. wind O ° mc!Oemored�ance=soowrnP Max Load P g ( g� � � Weight: 18 kg!39.68 lbs 0- Dimensions 1640 x 990 x 40 mm(64.56 x 38.97 x 1.57 Inches) � In dr;nt klE,�i'e�c�. 2P5w7nf " DRAWN BY: EH �l.o. E t3acksheet White: G t DATE: 5-14-14 s ,0 15 20 n M a0 45 w Frame (Nan-Refiective)Silver Anodized Aluminum-Alloy Voltage J-Sox lP 67 Rated MARKET: RESIDENTIAL Cables AHDC]Cable 4.0 mm'(0.006 inches'), BUILDING HT: 2 STORY /� 900 mm(35,43 in) MODULES: SMX-250P Cc „/� r @ Us ♦ Connectors MC4 8.25 kW �".t'!. SYSTEM kV: SM- 50—P. UySTED MOUNTING MSI TILE HOOKS .71Y�11 LJw — - - HARDWARESMX : i • •• • • • S • • i INVERTER: M215-60-2LL-S22-IG SIVIX Capital Inc. 17700 Castleton Street, Suite 488, • • •• S • • 0 Capital • Street, - a i i • • •ne Changzhou, AHJ: LAKE ELSINORE Wujin Hi-Tech Industrial Zone Changzhou,213161,China -- Wuyi SHEET NUMBER: E10 MAX SOLAR MAX RENEWABLE ENERGY PROVIDER INC 3080 12TH STREET, RIVERSIDE,CA 92507 TEL: (951)300-0788 FAX: (951)213-3099 Enphase M215 Microinverter//DATA CLASS#C-46 LIC#972048 CONFIDENTIAL-THE INFORMATION Enphase Microinverters INPUT DATA(DC) M215-60-2LL IG-S22/323/S24 HEREIN CONTAINED SHALL NOT BE _ USED FOR THE BENEm OF ANYONE EXCEPT SO x RENEWABLE Recommended input power(STO) 190-270 W ENERGY PROMDER INC.,NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Maximum Input DC voltage 48 V PART TO OTHERS OUTSIDE THE Enphase'DM215 Peak power tracking voltage 27 V-39 V RECIPIENT'S ESPECZnnON,EXCEPT IN CONNECTION WITH THE SALE AND USE Operating range of THE T,WTH UT HE RMAx 16 V-48 V EQUIPMENT,YATHOUT THE WRITTEN � PERMISSION OF SOLARMAX Mill/Max start voltage. 22 V 148 V. RENEWABLE ENERGY PROMDER INC. Max DC short circuit current 15 A Max input current � � .10 A 8 VAC rdr240 VAC ROBERT LIU OUTPUT DATA(AC)imam 020 .� Peak output power 225 W 225w LIC. HOLDER'S SIG. i „rat Rated(continuous)output power 215 W 215 W t Nominal output current 1.1 A(A rms at nominal duration) 0.9 A(Arms at nominal duration) Nominal voltage/range 208 V/183-229 V 240 V/211-264 V Nominal frequency/range 60.0167-61 Hz 60.0157-61 Hz r 1 Extended frequency range" 57-62.6 Hz 57 62.6 Hz Y7 Power factor >0.95 >0.95 u. s Maximum units per 20 A branch circuit 25(three phase) 17(single phase) Maximum output fault current 850 mA rms for 6 cycles 850 mA rms for 6 cycles W O EFFICIENCY � -_-_ � � � M ... ..,..,-.-. - N O N 1 CEC weighted efficiency,240 VAC 96.5°10 w CEC weighted efficiency,208 VAC 96.5% w U O N LIU Q T & N d U Peak inverter efficiency 96.5% Q ''�/^� Q W Static MPPT efficiency(weighted,reference EN50530) 99.4% Er �tl V J N O Night time power consumption 65 mWr�Max _. cn > Z w 0 o — The Erph se' M21 € i r inv ft r with integrated ground delivers increased energy harvest and MECHANICAL DATA _ __ 0° M � oa J o w reduces design and installation Complexity with its all-AC approach.With the advanced M215, the DC Lo Ambient temperature range -a©°G to+65°G W g w Electrode Conductor GEC IS re uired Dimensions(WxHxD) 163 mm x 173 mm x 25 mm(without mounting bracket) a o O Q circuit is isolated and insulated from ground,so no Ground { ) q for the microinverter.This further simplifies installation,enhances safety,and saves on labor and Weight Na kg(3Ature)convection J Cooling Natural -No fans materials costs. _ Enclosure environmental rating � Outdoor-NEMA 6 The Enphase M215 integrates seamlessly with the Engage Cable,the Envoy Communications FEATURES Gateway"°, and Enlighten"', Enphase's monitoring and analysis software ibility Go Compatible With 60 Dell Pv modules. Communication Power line w Integrated ground The DC circuit meets the requirements for ungrounded PV arrays in P O iJ C T i V E S i[AlP L E RELIABLE NEC 690,36,Equipment ground is provided in the Engage Cable. 0f No additional GEC or ground is required.Ground fault protection is L1 Maximizes energy production No GEC needed for microinverter More than 1 million hours of testing integrated into the microinverter. Minimizes impact of shading, No DC design or string calculation and millions of units shipped Monitoring Enlighten Manager and MyEnlighten monitoring options DRAWN BY: EH dust,and debris required Industry-leading warranty,up to 25 UL1741/IEEE1547,FCC Part 15 Class B,CAN/CSA-C22.2 NO.0-M91, DATE: 5.14-14 No single point of system failure Easy installation with Engage years Compliance 0,4-04,and 107.1-01 MARKET: RESIDENTIAL Cable Frequency ranges can be extended beyond nominal if required by the utility BUILDING HT: 2 STORY MODULES: SMX-250P SYSTEM kV: 8.25 kW f ha � G... To learn more about Enphase Microinverter technology, en 1 MOUNTING MSI TILE HOOKS HARDWARE: Q_ E N E R G Y C s VISIt O€t( h E .00t1t €., E N E R G Y INVERTER. M215-60-2LL-S22-IG 'Z�2014 Enphase Enemy.Al 69111s reserved.Al trademarks or brands in this document are registered by their respective owner. AHJ: LAKE ELSINORE SHEET NUMBER: Ell Soar MAX; SOLAR MAX RENEWABLE ENERGY PROVIDER INC 3080 12TH STREET, RIVERSIDE,CA 92507 TEL: (951)300-0788 FAX: (951)213-3099 CLASS#C•46 LIC#972048 CONFIDENTIAL-THE INFORMATION Enphase Engage Cable System//DATA HEREIN RCNTA THE ED FIT O NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARMAX RENEWABLE LL Engage Cable System and Accessories EIT BE NERGY PROVIDER INC.,NOR OR IN PART TO OTHERS OUTSIDE THEN CABLE TYPES/ORDERING OPTIONS a RECIPIENTS ORGANIZATION.THTHESAL EXCEPT IN CONNECTION ESP RESPECTIVE SALE AND USE © Voltage ' b of THE PERMISSION F s LARMASOLAR Ax Connector Spacing PV Module Orientation Model Number #Connectors` Weight- EQUIPMENT,WITHOUT THE WRITTEN EnphaseEngage 240 VAC,4 conductors 1.025 meter(40") Portrait ET10-240-40 40 40 Ibs PERMISSION G S PROVIDER RENEWABLE ENERGY PRONDR INC. � 240 VAC,4 conductors 1.7 meter(67") Landscape ET17-240-40 40 45 lbs 208 VAC,5 conductors 1.025 meter(40") Portrait ET10-208-30 30 30 Ibs % Landsca e ET17-208-30 30 35lbs ROBERT LIU 3 208 VAC,5 conductors 1.7 meter(67") p LIC. HOLDER'S SIG. "additional lengths available through Enphase authorized distributors."weights are approximate CABLE SPECIFICATIONS Description Rating Cable temperature rating 90°C(194°F)wet/dry ~ Cable insulator rating THWN-2 UV exposure rating UL 746 C,F1 t Conductor size 12AWG z Compliance IEC 60529 IP67,CAN/CSA 22.2 No.21,182.3,UL 486A/B,514C,6703,and 9703 W Cable rating TO-ER JLO Cable Diameter 1.25 cm(0.49") N J N Minimum bend radius 12 cm(4.75") w u O N'It W U > oQW ENGAGE ACCESSORIES w ti LO F- ry 0)o (VUO 'no > Z C.,Branch Terminator Disconnect Tool o m cn One terminator needed per branch Plan to use at least one per o a o L j circuit LO installation o a W The EIS ag6ATM Cable is a continuous length of 12AWG cable with pre-installed connectors for ET-DISC-05(sold in packs of 5) 0-0 N ET-TERM-10(sold in packs of 10) IZ Enphase Microinverters. The cable is handled like standard outdoor-rated electrical wire, allowing it < to be cut, spliced and extended as needed. The Engage Accessories complement the Engage Cable and give it the ability to adapt to any Watertight Sealing Cap -� Cable Clip Many needed to fasten cabling installation. ® One needed to cover each unused `— to the racking or to secure looped connector on the cabling cabling - ET-SE (sold in packs of 10) U ET-CLIP-100(sold in packs of 100) W FAST FLEXIBLE SAFE a IL - Quick installation Simple design No high voltage DC Large branch capacity No additional cables Reduced fire risk Engage Coupler DRAWN BY: EH ,.�� Used for splicing two power cables DATE: 5-14-14 within an array MARKET: RESIDENTIAL ET-SPLK-05(sold in packs of 5) BUILDING HT: 2 STORY MODULES: sMX-250P SYSTEM kV: 8625 kW $ To learn more about Enphase Microinverter technology, @ enphase, MOUNTING HARDWARE: MSI TILE HOOKS C. en aste, S� E N E R G Y h VISIt e@�E�krTa��eoE�4'brrk INVERTER: M215-60-2LL•S22-IG E N E R G Y C us 2013 Enphase Energy.All rights reserved.All trademarks or brands in this document are registered by their respective owner, j nHJ: LAKE ELSINORE SHEET NUMBER: E12 So/ar Azax SOLAR MAX RENEWABLE ENERGY PROVIDER INC 3080 12TH STREET, RIVERSIDE,CA 92507 TEL: (951)300-0788 FAX: (951)213-3099 Enphase Microinverters&Ungrounded PV Arrays CLASS#C-46 LIC#972048 CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE - - USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARMAX RENEWABLE Grounding Term ENERGY PRONDER INC.,NOR SHALL r` IT BE DISCLOSED IN WHOLE OR N PART TO OTHERS OUTSIDE THE Under NEC definitions in Article 100,two conductor types provide paths to ground.These are the RECIPIENT'S ORGANIZATION,EXCEPT IN CONNECTION WITH THE SALE AND USE Equipment Grounding Conductor(EGC)and the Grounding Electrode Conductor(GEC).Distinguishing OF THE RESPECTIVE SOLARMAX Enphase Microinvertersrids Ungrounded 1VI Arrays between the EGG and the GEC is important when ensuring a photovoltaic array is code-compliant and EQUIPMENT,WITHOUT THE WRITTEN �` PERMISSION OF SOLARMAX WRITTEN Enphase fVi250 and new M215 with Integrated Ground—no need for separate GEC safe.The following describes key terms from the NEC related to PV system grounding relevant to RENEWABLE ENERGY PRONDER INC. g p Enphase Microinverters. For reference,grounding requirements for microinverters are covered in UL1741 while grounding .. ROBERT LIU �CV�e requirements for photovoltaic systems are covered in the NEC under Article 250 with amendments in LIC. HOLDER'S SIG. Article 690.Always check with your jurisdiction for information about local amendments to the code. Enphase has developed a new microinverter family that includes the M250 and new M215 with integrated Underwriters Laboratory(UL)Standard 1741 grounding requirement: (DC isolated)ground.Because the DC circuit is isolated and insulated from ground,these microinverters do not require a Grounding Electrode Conductor(GEC)connected between each microinverter.The In Spring 2012,UL issued a document amending UL 1741 to address inverters for connection to Enphase Microinverters with Integrated Ground are compatible with most 60-cell PV modules(210W to ungrounded PV arrays.Enphase Microinverters with Integrated Ground have been successfully 30OW STC or higher)and install quickly and easily.They work with either three-phase 208 VAC or single- evaluated against this document.Therefore,a grounding electrode terminal for the attachment of phase 240 VAC services.Enphase Microinverters ship with integrated DC and AC cables and a GEC is not required for this microinverter.All required grounding for Enphase Microinverters connectors.The DC connectors attach to the PV module,while the AC connector attaches to the EngageTM Cable.No additional cabling is needed. with Integrated Ground is met by the AC R:GC supplied by the Engage Cable system and meets both NEC and UL requirements. Z An ungrounded array,when coupled with sophisticated features of the Enphase Microinverters with National Electric Code grounding definitions: W o Integrated Ground,offers greater safety for the installer,system owner,and maintenance personnel. In addition to enhancing safety,the integrated ground technology streamlines,simplifies,and economizes Y 0 J LID the installation process for installers and inspectors of all project types. The Grounding Electrode System:Described more fully in NEC Article 250 Part III,the � J grounding electrode system provides a network of conductors,bus bars and bonding within a w This document clarifies solar grounding terminology and describes NEC(National Electrical Code) facility through which a direct connection to earth is established.The grounding electrode system W>_ 0 N w Q compliant grounding methods for Enphase®Microinverters with integrated(DC isolated)ground.The is comprised of the equipment ground conductor,the grounded conductor,the grounding N o > U 2008,2011 and 2014 editions of the NEC allow for ungrounded PV arrays based on the provisions electrode conductor,and the grounding electrode. W CO It specified in NEC article 690.35. 0 0 N > O Grounding Electrode: Is a conducting object through which a direct connection to earth is 0 o M> Z established per the requirement outlined in NEC 250.52.Typical examples of a grounding LU 0 0 0 electrode are a ground rod,buried metal pipe,plate electrode,concrete encased ground(LIFER), a 0. J Cl) W and/or a ground ring. °a w ap O�/ Y Features Equipment Grounding Conductor(EGG):Provides a conductive path to connect normally non- L.L. —� • Integrated ground eliminates the need for a GEC: Enphase Microinverters with Integrated current-carrying metal parts of equipment together.EG=Cs are also found in traditional household Q Ground isolate the DC conductors from ground.This has the significant advantage of eliminating wiring and connected to the rounded contact in a three-hole,grounded wall socket.The EGG is the need for a GEC connection between microinverters. also used in the PV industry to connect all exposed metal parts such as PV module frame, • Ground fault detection on board:Enphase Microinverters with Integrated Ground offer racking structure,wiring enclosure(combiner and junction boxes),and the microinverter chassis. advanced features to detect DC ground faults on either DC positive or negative conductors and With Enphase Microinverters with Integrated Ground,the F GC is supplied through the Engage always check the insulation resistance before exporting power.This eliminates the hidden ground Cable system. U faults that often go undetected with less mature microinverter technologies. uJ Grounded Conductor:The NEC defines the grounded conductor as a current-carrying O • Smart disconnects:As on all Enphase Microinverters,the AC and DC connectors are rated and conductor that is intentionally grounded. Examples are the Neutral conductor found in an AC 0 listed as disconnect devices under load per the NEC requirements.This simplifies design and system or a grounded DC conductor found in many PV systems.The point at which the Current- CL eliminates the need for redundant and hard-to-locate disconnect devices. carrying conductor is connected to ground must be connected to the grounding electrode with a • Ruggedized DC wiring: Each Enphase Microinverter with Integrated Ground is built with PV GEC. DRAWN BY: EH (Photovoltaic)Wire for all DC conductors.This provides double insulation for protection against DATE: 5-14-14 wire damage and meets all wiring requirements of NEC 690.35.The PV module must also use Grounding Electrode Conductor(GEC):The purpose of the PV Wire. path to connect the common grounding point of the power systemem(( is to provide a conductive AC or PV power systems)to MARKET: RESIDENTIAL the grounding electrode or to a grounding electrode system.AC or PV power system grounding is BUILDING 2 STORY established when a current-carrying conductor is intentionally connected to ground by a GEC. MODULES:: SMX-250P SYSTEM kV: 6.25 kW MOUNTING MSI TILE HOOKS HARDWARE: INVERTER: M215-60-2LL-S22-IG -. _ . .. AHJ: LAKE EL SINORE 1 ©2014 Enphase Energy Inc.All rights reserved. January 2014 2 ©2014 Enphase Energy Inc.All rights reserved. January 2014 SHEET NUMBER: E13 So/ar , /UI . SOLAR MAX RENEWABLE ENERGY PROVIDER INC 3080 12TH STREET, RIVERSIDE,CA 92507 TEL: (951)300-0788 FAX: (951)213-3099 Enphase Microinverters&Ungrounded PV Arrays Enphase Microinverters&Ungrounded PV Arrays CLASS#C-46 LIC#972048 CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE p pg EXCEPT SOLARMAX RENEWABLE NOR SHALL Building g Arrays with Grounding i Ir`',a r���� �t�� r ted iicrotll�v iter� System roan IT BE DISCLOSED IN ERGY PROMDER WHOLE OR N PART TO OTHERS OUTSIDE THE Many methods are available for installing PV systems that enable a variety of approaches both to system Like the Enphase M190 and the previous generation M215,the Enphase Microinverters with Integrated CONNECTION RECIPIENTS ORGANIZATION,WITHTHESAL EXCEPT IN CONNECTION WITH SALE EANDXCEPT USE design and to system grounding.We discuss two common methods and place emphasis on specific Ground are utility-interactive microinverters.All Enphase Microinverters use transformer coupling to OF THE RESPECTIVE SOLARMAX isolate the DC and AC circuits.The major difference between the grounded and integrated ground EQUIPMENT,WITHOUT THE WRITTEN grounding requirements. PERMISSION OF SOLARMAX models lies within the DC input stage of the microinverter,where DC power from the module enters the RENEWABLE ENERGY PRONDER INC • Wire EGC:The PV modules are mounted to the racking platform with mechanical clamps and microinverter.Enphase Microinverters with Integrated Ground do not ground the DC input,as did their clips.As per NEC 690,43,all exposed metal must be grounded.An EGC provides a conductive predecessors.By isolating the DC conductors from ground,Enphase Microinverters with Integrated path for the racking and PV module frames.The EGG is connected to each PV module frame and Ground enable the installer to create an NEC-compliant Ungrounded PV Power System(690.35,690.41). _ROBERT LIU all racking members.The EGC from the array can be connected to the AC EGC that then connects to the AC ground system. With the Enphase Microinverters with Integrated Ground,the grounding requirement is satisfied with an LIC. HOLDERS SIG. EGC,so a GEC is not required.The EGC is provided through the Engage Cable system that has been certified and listed for this application. Main Panel Board ne Ground Bond Equipment Jumper(GBJ) _ '� ac EGCI Ground Conductor Neutral Bar Ground .. :. (EGC) Neutral _ -------------- -_k --- -" Electrode ,. Conductor W Ground (GEC) Bonding Point Ground Bar // Racking / O AC EGC GFDI Invert - a) AC Nu- N ro� j� Ground ._._ Electrode w y O N w Q 8 B 0 0 0 >-DC O w< � Hd' Enphase Microinverters with Integrated Gro€ nd with EGG Connecting PV Frames and >o covJ N � O Packing Enphase Mdicroinvorters with Integrated Ground:Ground Connections o M> z a 0 � M J • WEEBs:WEEB equipment bonding washers can be used to connect the PV modules to each °I v LO uJ other or to the racking for the purpose of equipment grounding.NEC 690.43 and 250.136(A) In previous models,the DC input was bonded to ground through a GFDI circuit.This essentially grounded °0 W allow for the equipment to be electrically connected to mounting structures that are themselves the PV module's output.This construction required connection from this point to the grounding electrode a° Q grounded,and the electrical connection bonds the equipment frame to ground.To be considered using a GEC.However,since Enphase Microinverters with Integrated Ground isolate the DC conductors —I grounded,the mounting structure must be connected to an equipment-grounding conductor. from ground,only a simpler EGC is required.The EGC is provided within the Engage Cable system, Q WEEBs can only be used as part of the EGC system. which connects seamlessly to the AC power system output of the microinverter. xc a c Main Enphase Microinverters with Integrated Ground detect ground faults in either the DC positive or negative rYw x r conductor of the PV module by detecting the insulation resistance of each conductor to ground.Also new ux 3 Equipment Panel Board to Enphase Microinverters with Integrated Ground is the Insulation Monitor(IM),which measures the � Ground Bond U Ground insulation resistance of the DC circuit with respect to ground.Together,these features offer greater safety WEEB Conductor Jumper GBJ I1J P � ) r x Bond (EGC) / than previously possible in any inverter technology. 0 Jumper Neutral Bar / Ground W Neutral jBa.r Electrode Conductor eodr gnPolnt Grou (GEC) Acronyms s and Definitions Rackin ,.....ou DRAWN BY: EH AC Alternating Current AC L:GC DATE: 5-14-14 DC Direct Current Ground .__._ EGC Equipment Grounding Conductor MARKET: RESIDENTIAL tr 4 Electrode Engage Cable Enphase cable system listed for use with Enphase products — GEC Grounding Electrode Conductor BUILDING HT: 2STORY p 0 0 0 0 r GFDI Ground Fault Detection and Interruption MODULES: SMX-250P IM Insulation Monitor 8.25kW NEC National Electrical Code SYSTEM kV: Enphase Microinverters with Integrated Ground with WEEB Ground Jumpers PV Photovoltaic HARDWARE MSI TILE HOOKS : WEEB Washer,Electrical Equipment Bonding INVERTER: M215-60-2LL-S22-IG AHJ:-,- LAKE ELSINORE 3 ©2014 Enphase Energy Inc.All rights reserved. January 2014 4 ©2014 Enphase Energy Inc.All rights reserved. January 014 2 SHEET NUMBER: E14 AUX SOLAR MAX RENEWABLE ENERGY PROVIDER INC 3080 12TH STREET, RIVERSIDE,CA 92507 TEL: (951)300-0788 FAX: (951)213-3099 CLASS#C-46 LIC#972048 CONFIDRIES; ON HERONECONTAINED SHALL NTNTIAL-THE nBE USED FOR THE BENEFlT OF ANYONE @EXCEPT SOLARMAX RENEWABLE . ,. �. .. f. .. ENERGY PROVIDER INC.,NOR SHALL . ,.. IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE REGPIENYS ORGANIZATION,EXCEPT IN Eri 'l-lase Microinverterswith Integrated t pm t Ground (I ) CONNECTION WITH RESPECTIVE HE SALE AND OF THE RESPECTIVE SOLARMAX EQUIPMENT,WITHOUT THE WRITTEN PERMISSION OF SOLARMAX RENEWABLE ESIERGY PROVIDER INC. Enphase's latest generation microinverters feature Integrated(DC isolated)Ground.Because the DC circuit is isolated and insulated from ground,these microinverters do not require a Grounding Electrode `- Conductor(GEC)connected between each microinverter.This means you don't need to attach a ROBERT LIU separate copper grounding conductor to each microinverter or worry about a continuous run to ground. LIC. HOLDER'S SIG. The result is faster installation with lower materials costs and a safer system. Integrated ground and code requirements Solar installers must comply with the National Electrical Code(NEC)when installing Enphase Microinverters.Enphase Microinverters with Integrated Ground meet the requirements specified for Ungrounded PV Power Systems in sections 690.35 and 690.41 of the 2008,201 land 2014 NEC. It also meets the Underwriters Laboratory(UL)Standard 1741 grounding requirements. For further information,refer to the whitepaper on Enphase Microinverters and Ungrounded PV Arrays Z and other materials at enphase.com/Grounding. W 0 3� _j M �.,� Microinverters No grounding N� N LO ) CrYiti`1a terminal w with Integrated round � W� � N w Q N N CC �' V Installers and inspectors can easily Plated < G1 Q ui identify Enphase Microinverters with J , (— Integrated Ground. o N O Wo ^ Z Lu0 oO M co a Product label to W e on bottom W with Integratedrun x��� a o 0 Y <.....-----•--- edge Enphase Microinverters ship with DC and AC cables and connectors.The DC connectors attach to the PV module,while the AC connector Q attaches directly to the Engage'"Cable. It's that simple:no additional cabling is needed. � About systern grounding Electrical code requires two types of grounding conductors:the Grounding Electrode Conductor(GEC), U which is used between the grounding electrode and the point where a normally current carrying conductor W is intentionally bonded to ground and the Equipment Grounding Conductor(EGC),which grounds non- 0 current carrying metal parts of the system,such as the racking and module frames. a Because Enphase Microinverters with Integrated Ground have DC integrated ground,they do not require a GEC.However electrical code still requires that exposed metal in the array be grounded(NEC 690.43 DRAWN BY: EH and 250.136(A)).This requirement is met for the microinverter because the ground conductor internal to 5-14-14 the Engage Cable acts as the EGC. It may be met for racking and modules with use of an EGC or DATE: WEEBs to provide bonding to this ground system. MARKET: RESIDENTIAL BUILDING HT: 2 STORY MODULES: SMX-250P SYSTEM kV: 8.25 kW MOUNTING HARDWARE: MSI TILE HOOKS INVERTER: M215-60-2LL-S22-IG ©2014 Enphase Energy Inc.All rights reserved.January 2014 AHJ: LAKE ELSINORE SHEET NUMBER: E15 solar; AWK, DY® @ WEEB COMPATIBILITY SOLAR MAX RENEWABLE ENERGY PROVIDER INC BU N The WEEB family of products can be used to bond anodized aluminum, galvanized steel,steel 3080 12TH STREET, and other electrically conductive metal structures.All installations shall be in accordance with RIVERSIDE,(9D o0 0788 NEC requirements in the USA and with CSA C22.1 in Canada.The WEEBs are for use with FAX: (951)213.3099 CLASS#C-46 LIC#972048 modules that have a maximum fuse rating Of less than 25A. CONFIDENTIAL-THE INFORMATION Washer, Electrical Equipment Bond HEREIN CONTA BMEFIT OF INED SHALL NOT BE Certain module frames do not have enough structural strength to withstand the force required to O EDXCEPTT SOIARMAX RENEWABLE NERGY PROVIDER NOR embed a WEEB.These frames will deform and therefore not allow sufficient penetration of the ET BE DISCLOSED IN WHOLE OR IN WEEB WEER teeth. The general requirements for minimum module frame thickness of boxed type TSIDE THE RECIPIENTS ORGANIZAT TO OTHERS TION,EXCEPT IN module frames are illustrated below. For more information regarding module compatibility, CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARMAX please see the technical documents section of our website. EoUIPPEMEENT. ,OLT WRITTEN OF SOLARMAX M8 Socket Cap Screw RENEWABLE MGY PROVIDER INC. INSTALLATION INSTRUCTIONS M8 Serrated For Everest Solar CrossRail 36 and CrossRail 48 Everest Solar .— Belleville Washer ROBER I LIU Mid Clamp LIC. HOLDER'S SIG. , Mounting Systems Only F71 Burndy LLC recommends that the sufficient details of the installation be submitted to the AHJ for approval before any work is started. Anodized aluminum p y PV module frame Compression Spring W co PLEASE READ 3 K o "I "' CAREFULLY � J N BEFORE W O NwQ INSTALLING N L uU O W LO ♦— WEEB-KMC I )-o N O I 0E- Q M Z 0 o cn M J a DE �''t0{� LU ® NO LESS THAN 3.00mm a o O Q Everest Solar M K2 Slot Nut with Clip NO GREATER THAN 8.50mm ® NO THINNER O THAN 1.50mm � � U Lu O WEEB-KMC WEEB-LUG-8.0 DRAWN BY: EH Note. DATE �L/�,, US 5-14.14 ® - C \,� MARKET: RESIDENTIAL Products are tested to UL 467, CAN/CSA C22.2 No. 41 ..� Inspect each module frame used with a WEEB to ensure that the bottom mounting face of 2 STORY BUILDING HT: US/ Canadian standards for safety grounding and bonding equipment. Intertek the frame is flat, and that there are no hindrances to embedding WEEB teeth. Do not use a MODULES: SMX-250P 4004188 module with a frame that prevents the WEEB teeth from embedding fully. 8.25kW SYSTEM kV: MOUNTING MS!TILE HOOKS Document Number 50015303 Rev C HARDWARE 0 2013 BURNDY LLC INVERTER:: Document Number 50015303 Rev C . BURNDT M215-60-2LL-S22-IG I L (9 t4 ��; 0 2013 BURNDY LLC. HUBBELL Page 2 of 6 LAKE ELSINORE Page 1 of 6 AH. SHEET NUMBER: E1_6 Solar", /UTAX. SYSTEM OVERVIEW OF EVEREST SOLAR SYSTEM OVERVIEW OF EVEREST SOLAR SYSTEM USING C RO S S RAI L 48 SOLAR MAX RENEWABLE SYSTEM USING CROSSRAIL 36 ENERGSIDE,C 92507 ER INC 3080 12TH STREET, RIVERSIDE,CA 92507 TEL: (951)300-0788 FAX: (951)213-3099 CLASS#C-46 LIC#972048 CONFlDENRAL-THE INFORMATION When position of solar modules HEREIN CONTAINED SHALL NOT BE When position of solar modules USED FOR THE RMAXBENE R OF ANYONE is finalized, torque fasteners to EXCEPT SO IDER INC..RENEWABLE is finalized,torque fasteners to ENERGY PROHDER IN NOR SHALL 10ft-lb/ 13.5N-m using Penetrox-A IT BE DISCLOSED IN WHOLE T IN 10ft-lb/ 13.5N-m using Penetrox-A PART TO OTHERS ORGANIZATION, OUTSIDE THE on threads. CONNECTION O ITH THE SAL EXCEPT IN on threads. OF THENRESPEC THE S�OLARMAX • EQUIPMENT,WITHOUT THE WRITTEN • PERMISSION OF R NEWABLE ENERGY PRONDER INC. ROBERT LIU LIC. HOLDER'S SIG. Z J o L0 N� J N W� j wa) O N W Q v� d U nv C 0 c � W Assemble WEEB-LUG-8.0 assembly Assemble WEEB-LUG-8.0 assembly o N > O usingM8 T-Bolt and Flange Nut. W o r, > z 9 using M8 T-Bolt(with an M10 T-Bolt Head) W o Torque fasteners to 10ft-lb/13.5N-m and Flange Nut. Torque fasteners to o Q J L W using Penetrox-A on threads. 10ft-lb/ 13.5N-m using Penetrox-A on threads. n U) Q Lay in equipment -' Lay in equipment ground conductor Q ground conductor and torque bolt to and torque bolt to 7ft-lb/ 1 ON-m. 7ft-lb/10N-m. "1 LUG per rail/rail run" "1 LUG per rail/rail run" ~ U W O Important notes: Important notes: 1. Use general purpose anti-seize compound on fastener threads when installing WEEBs. DRAWN BY: EH 1. Use general purpose anti-seize compound on fastener threads when installing WEEBs. 5_14.14 2. The NEC section 690.43 states"Exposed non-current carrying metal parts of module 2.The NEC section 690.43 states"Exposed non-current carrying metal parts of module DATE: frames, equipment, and conductor enclosures shall be grounded in accordance with MARKET: RESIDENTIAL frames, equipment,and conductor enclosures shall be grounded in accordance with „ BUILDING HT: 2STORY 250.134 or 250.136(A) regardless of voltage . 250.134 or 250.136(A)regardless of voltage", 3.WEEBs are intended for SINGLE USE ONLY. Functionality will not be guaranteed if reused. MODULES: SMX-250P 3.WEEBs are intended for SINGLE USE ONLY. Functionality will not be guaranteed if reused. SYSTEM kV: 8.25kW MOUNTING MSI TILE HOOKS Document Number 50015303 Rev C Document Number 50015303 Rev C BURNDY` HARDWARE: ©2013 BURNDY LLC. BURNDYfjy ©2013 BURNDY LLC. INVERTER: M215-60-2LL-S22-IG " UJILy Page 3 of 6 Page 4 Of 6 A"J LAKE ELSINORE SHEET NUMBER: E17 Solar',z WEEB-KMC LAYOUT SPLICE KIT ASSEMBLY NNX ABLE FOR CROSSRAIL 36 ENERGYPROVIDOLAR MAX PROVIDER ENERGY PROVIDER INC 3080 12TH STREET, RIVERSIDE,CA 92507 EVEN NUMBER OF MODULES IN ROW Everest Solar CrossRail 36. TEL FAX: (951)213-3099 FAX: (951)3000788- CLASS#C-46 LIC#972048 CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE Copper Cable. ENEREXCEPT PROVIDERSOLARMAX INCRENEWABLE NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION,EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARMAX EQUIPMENT,TWTHOUT THE WRITTEN PERMISSION OF SOLARMAX R NEWABLE ENERGY PROVIDER INC. LIU Everest Solar Connector ROBERT for CrossRail 36. LTC. HOLDER''SS SIG. X DENOTES PLACES TO INSTALL WEEB-KMC WEEB-LUG-8.0 fastened on the CrossRail 36 using M8 T-Bolt and Flange Nut. Torque fasteners to C X R = 4 X 1 1 Oft-Ib/13.5N-m using Penetrox-A on threads. WEEB-KMC NEEDED = C X R = 4 X 1 = 4 SPLICE KIT ASSEMBLY z ODD NUMBER OF MODULES IN ROW FOR CROSSRAIL 48 Y� w C)J Everest Solar CrossRail 48. J M wU) O N W Q w < LNG Copper Cable. �o N o No 0 M> Z � J OQW o K CIL < p `� W IL 0 X DENOTES PLACES TO INSTALL WEEB-KMC Everest Solar Connector for CrossRail 48. C X R = 5 X 1 WEEB-LUG-8.0 fastened on the CrossRail 48 W WEEB-KMC NEEDED = [C+1] X R = [5+1] X 1 = 6 using M8 T-Bolt(with an M10 T-Bolt Head)and Flange Nut. o Torque fasteners to 10ft-lb/ 13.5N-m using Penetrox-A on threads. a Note: Customer Service Department DRAWN BY: EH 7 Aviation Park Drive DATE: 5-14-14 When replacing a single faulty module, also remove the adjacent module which contacts Londonderry, NH 03053 MARKET: RESIDENTIAL the same WEEBs as the faulty module.This will ensure that there are never ungrounded 1-800-346-4175 BUILDING HT: 2 STORY modules in the array. 1-603-647-5299 (International) MoouLEs: SMX-250P SYSTEM kV: 8.25 kW MOUNTING Document Number 50015303 Rev C Document Number 50015303 Rev C HARDWARE: MSI TILE HOOKS ©2013 BURNDY LLC. BURNDY' ©2013 BURNDY LLC. BURNDY` INVERTER: M215-60-2LL-S22-IG Page 5 of 6 Page 6 of 6 ,. AHJ: LAKE ELSINORE SHEET NUMBER: El 8 So/ar' M4X'i SOLAR MAX RENEWABLE ENERGY PROVIDER INC 3080 12TH STREET, RIVERSIDE,CA 92507 General Duty Safety Switches—Class 3130 General Duty Safety Switches—Class 3130 TEL: (951)300-0788 FAX: (951)213-3099 CLASS General Information General Information #972 ASS#C-46 LICIC#972048 CONFIDENTIAL-THE INFORMATION Application Standards class R Fuse Horsepower Ratings HEREIN CONTAINED SHALL NOT BE Catalog Kits Field 120Vac 240Vac 240Vac USED FOR THE RMAXBENEFIT OF ANYONE Series Installablet EXCEPT SOIDERIN RENEWABLE General duty safety switches are designed for the General duty safety switches are manufactured in Number Std. Max. Std. Max. ENERGY PROVIDER INC.,NOR SHALL IT BE DISCLOSED IN WHOLE OR IN fdInwing appliratinns: accordance With these standards: Catalog Number 1m 1Q 10 30 1m 4 PART TO OTHERS OUTSIDE THE utlyd 2 E2 N/A /z yt 3 RECIPIENTS ORGANIZATION,EXCEPT IN • Residential and light commercial applications. UL 98,Standard for Enclosed and Dead Front L2i1N E2 wA v,* 2* Yz* 3* CONNECTION WITH TIV SALE OL AND USE Switches.UL Listed under File E2875. L22iN E2 N/A '/z* 2* /a* 3* OF THE RESPECTIVE HE WRITTEN • Infrequent Or moderate operations. .. EQUIPMENT,PERMISSION LA MRIT1Bq D211N E3 N/A '/a 2 iy1 3 PERMISSION OF SOLARMAX 240 Vac maximum. NEMA Standards Publication KS1,Enclosed D211NRB E2 DIRK /� 2 11/2 3f• 3 7,/Zf RENEWABLE ENERGY PROVIDER INC. Switches. D221N E3 DRK30 D221MR8 E3 DRK30 ivy 31 3 T/pf • Up to 100,000 rms symmetrical amperes, D222N Ft RFK03L 1Ys 3 3 7/,4 10 15+ using appropriately rated Class R fuses and Federal Specifications WS 865c for Type NDS NEMA Type l land Type LID NEMA Type a D222NRB F1 RFK03L v, 3 311111112 54 10 154 304 Class R Fuse Kits,or ClassT or J fuses. f yp yp { yp } D223N F3 RFK10 71Z 154 15 301 ROBERT LIU D223NR8 F3 RFK10 - • 30-800A. D224N E3 DRK1020 ... is 25� -- SM LIC. HOLDER'S SIG. • Horsepower rated. U D225N E3 DRK40 L Listed Short Circuit Withstand Rating D224NRB E3 DRK (RMS Symmetrical) 0 D225NR Et DRK40 0226N E3 DRK600 The light duty enclosed switch is ideal for home Switch Type Fuse Class Short Circuit Rating ( D226NR El DRK600 .g=- na= applications in disconnecting power to Plug 10,000 D321IN E3 DRK30 Y7 3 3V2workshops,hobby rooms,furnaces and garages. H 10.00D D321NR6 E3 DRK30 1Yz 3 37'/2Fusible J 100,000 D322N Ff RFK03L 1yy 3 3 7Vi 10 15 R 100,000 D322NRB F1RFK03L 112 3 3 ]'17 10 15 • Light duty—visible blades 10,000 A short T 100,000 D323N F3 RF(t0 7YZ 5 5 30 D323NRB F3 RFK10 7Y� 15 15 30 circuit current rating H 10,000 15 25 50 D324N E4 DRY,1020 15 25 50 • 30 A fusible and not-fusible Not FusgrleA R 100,000 D324NRB E4 DRK1020 • Rreplacement parts not available. T 100,000 D325N E3 DRK40 50 25 Z 0325NT E3 N/A 50 L211N A The UL Listed short.circuit current feting for Square 0 Company D325NR E1 DRK40 ... 50 ... 125 W general duty,notfusedsw fiches is based on thew itch being used 50 O in conjunction with fuses.Evaluation of nolfused sw itches in D325tJTR E7 N/A L J M Y conjunction with molded case circuit breakers has notbeen 0326N E3 DRK600 ... 75 ... 150 N O N performed.It a UL Listed short-oilwit current rating Is required,this D326NT E3 N/A W O not fused switch must be iepiscedwiths SquareD generslduty D326NR Et DRK600 _ ... 75 150 fusible safety sw itch equipped th the appropriate class and size D326NTR E1 N/A 75 W Go O N W Q tusing.T he UL Listed shod.circuit current rating ofthe fusible switch DU221RB* E2 N7A ... ... ... 3 ... N �..� is typically as follows:when used w ith Class H end Kfuses- DU222RB* E1 N/A 10 ... co v O 10,000 A,Class R fuses-iOD,000A.Consult thew icing diagfam of rn f W DU321* E2 WA 3 71/2 W V the sp itch to veriy the UL Ustedshort-circuN current na5ng. V/ DU321RBic E2 N/A _ }O NCO 10 15 Terminal Lug Data DU32 RB* El N/A 10 s w o Q o Z Ampere Conductors Wire Range 15 30 C) UJ LugWireRange DU323* F3 NIA 15 30 O d J O ijf Rating Par Phase Wire Belding Space Per NEC®Table 373-6 DU323RB* F3 N/A 25 50 aOf in Line 1 12-6 AVVG(AD or 146 AWG(Cu)* 12J3 AWG(AI)or 14-6 AWG(Cu)* DU324* E3 N/A "' 25 50 g �- W 30 14-8 AWO WiC u) DU324R8* E3 N/A 'L O Q Load 1 14-8 AWG(AVCu) DU325* E3 N/A ... ._ 150 A' ED 1 10�AVVG(AD of 143 AWG(Cu) 10-2 AWG(At)or 14-2 AWG(Cu) DU326■ E3 NIA .__ 150 ' r —I 10 100 1 12-1 AWG(AD or 141 AWG(Cu) 12-117 AWG(AD or 141N AWG(C u) 00200TRov G3 N/A ... .. ... _ .._ 0026ONATAV E2 N/A 10 200 1 2AWG-25Okcmil(AD1 of 2AWG-300kcmil(ADP or 002000NRBao E1 N/A _.. _.. ... .._ 20 ... 4AWG-250kcmil(Cu)1 4AWG-300 kcmil(Cu)� 002000NSLo E1 N/A 20 (1)1 AWG-SOOkcmil(AVCu)of T327N E1 N/A ... ... .. ... 100 400 2 1AAWG-250kcmlt(AVCu) (2)iI0 AWG-250 kcmil(AVC u) T327NR E1 N/A ... ... ... ... ... 100 WG-500 kcmil(AVCu) 4 AWG-600 kcmil(AVCu) t Rejection kits are waitable for Series D2,Et,E2,end Ft switches.when installed.this kit rejects all but Class R fuses.When installed with this kit 600 2 4A 0-50 ksmil AVCu) 3rD AW 0-500 k pnil(AVCu) and Class R fuses.the switch is UL Listed fur use on systems with up to 100.000 RMS symmetrical amperes aaeilable fault current. 3i0 V G 800 -3 ( 1 For cornergrounded delta systems. * Excluding BAWG solid. * Suitable for use as service equipment:requires field installation of a service grounding kit(see Digest 171,page 3-3)Solid neutral assembly LUL.t 1 6AWG-250kernil on load side of not fusible devices. SIJ225KA forthe case s ith;see Dig 0 4 BAWG•300kcmil on load side of not fusible deices. L Enclosed molded case switch;see Digest 171,page 1-20. O v Includes factory installed grounding Wt. ❑ includes factory installed solid neutral. IL • Not service entrance rated;see Digest 171,page 1-20 for more information. ■ Suitable for use as service equipment;requires field installation of solid neutral assembly D6005N. * For single-phase horsepower rating use two switching poles. DRAWN BY: EH DATE: 5-14-14 MARKET: RESIDENTIAL BUILDING HT: 2 STORY MODULES: SMX-250P 1887-1999 Schneider Electric All Rights Reserved SYSTEM kV: 8.25 kW D 7 B 12/99 ❑ MOUNTING ©1987-1999 Schneider Electric All Rlgtris Reserved HARDWARE: MSI TILE HOOKS 12199 INVERTER: M215-60-2LL-S22-IG AHJ: LAKE ELSINORE SHEET NUMBER: E 19 solar,",, / IZAX," SOLAR MAX RENEWABLE ENERGY PROVIDER INC Product data sheet H0M612L100RB IVERSIDE,CA9 50 � • e � ® e g RIVERSIDE,CA92507 Characteristics LOAD CENTER HOM MLO 240V 100A 1 PH 6SP FAX: (951)21033099 CLASS If C-46 LIC#972048 Cmuse-Hinds Product availability: Stock-Normally stocked in distribution facility CONFIDENTIAL-THE INFORMATION Price*: 129.00 USD HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARMAX RENEWABLE ENERGY PROVIDER INC.,NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION,EXCEPT IN Main CONNECTION WITH THE SALE AND USE MAX Applications: Certifications and Compliances: Commercial Status Commercialised OF THE REWITHOUTSPECTIW HESOLARITT EQUIPMENT,WITHOUT THE WRITTEN MAX Cooper Crouse-Winds Solar Pass Through Boxes(sometimes referred to as'transi- •cEfLus 1741 Listed Product or component Load Center PERMISSION of SOLARDER •cEfLus Listed t0 CSA Standard C22.2 No.31&No.107.1 p RENEWABLE ERCY PROVIDER ING lion boxes")are used In residential applications to provide a low profile,costeflec- type Live way to group input wires/circuits from several arrays and/or solar panels and •NEMA 4X Range of product Hoeline t m transition fromsolar(PV)cabletoregularbuildingwire.The Pass Through Box was --�� designed for PUapplications where over current protection is not necessary due to Load center type Fixed Maine(lugs) ' ROBERT LIU the low power rating of the PV string. [In]rated current 100 A Materials and Finishes: LIC. HOLDER'S SIG. Number of spaces 6 Features' •Hot compression mold fiberglass reinforced thermoset polyester Short-circuit current 10 kA •Non•Conduclive,impact resistant,UV resistant,flame retardant It •Rated 600VDC continuous duty Number of circuits 12 •Constructed in accordance with UL 1741 standards and provides spacious wiring •Poured Polyurethane seamless gasket provides water-tight,dust-tight eriviron room for quick easywire termination menial seat Number of tandem 6 circuit breakers •Factory installed multi-hole solar cord grip provides dependable secure wire •Stainless sleet used on all external hardware o termination to enclosure and saves field installation-eliminating the need for Network number of 1 phase ; enclosure drilling-saving time'&labor phases •Fiberglass enclosureswith captive stairdess steel screws and formed-in-place [Us]rated operational 120f240 VAC -$ polyurethane seamless gasket provided as standard voltage •Available in N3R shoat steel enclosures-consult factory z •Lightweight design offers easy mounting capabilities Optional mounting feet are o v a availableforincreasedcustomarflexibility ;8 W •Rated for continuous operation at 60°C Complementary C O _ _ J M ao AWG gauge 8...1 AWG copper 8 5^ N J N 0 i 8...1 AWG aluminium =tk (A at I `- NEMA degree of protection NEMA 3R outdoor E N. o w~n O N W Q t�Dt)f$q for ((o }/J1 Cover type Surface cover ;€ U o �j U �Qr,��{,,�w__s _...,.. Device composition Grounding bar(ordered separately) g$ w F '^ 4 t¢- af0°(r _ Electrical connection Lugs € o o O N in > Wiring configuration 3-wire E u d w 0 O (0 (n Tin plated aluminium bulbar n o 0- J o L j Q K l0 s Enclosure material Welded galvannealed steel — Q.g O •— W ,��.. Solar Pass Through Box ` ordering Information m Q Cover Gray baked enamel n/ Product certifications UL listed file E-6294 { LL GA# Description 'Cat,# Description CPBF03 3 Circuit Pass Through Box CPBF20 20 Circuit Pass Through Box Ordering and shi r it I details € p OPOF04 4 Circuit Pass Through Box CPBF21 21 Circuit Pass Through Box Fp OJ T CPBF05 5 Circuit Pass Through Box 6P8P22 22Gtrgutt Pass Th rough Box Category 00149-H0M2-8CiCf,ML0,NEMA1&3R Discount Schedule DE3C CPOF06 6Cireuil Pass Through Box CPBf23 23 Circuit Pass Through Box ° 00785901061205 E gtao 0 OPBF07 7 Circuit Pass Through Box CPBF24 24 Circuit Pass Through Box GTIN W �. CP8F08 8Circuit Pass Through Box CPBF25 25Circuit Pass Through Box Nbr.ofun its inpkg. 1 o O l CPSF09 9 Circuit Pass Through Box CPBF26 26 Circuit Pass Through Box Package weight(Lbs) 9.92 CPIRFi0 1,0 Circuit Pass Through Box CPBP27 27 Circuit Pass Through Box Product availability Stock-Normally stocked in distribution facility a - Retumabili Y OPBF11 11 Circuit Pass Through Box CPBF28 28 Circuit Pass Through Box ty EH o�A n� DRAWN BY: CPBF12 12 Circuit Pass Through Box 'CIROM 20 Circuit PassThrough Box' Country of origin MX F d o € DATE: 5-14-14 CPBF13 13 Circuit Pass Through8ox CPBF30 30CircuitPassThroughBox E��� ar=2 CPBF14 14Circuit Pass Ttv'oughBox CPBF31 31 Circuit Pass Through Box Contractual warranty 9�o g MARKET: RESIDENTIAL CPBF15 15 Circuit Pass Through Box CPBF32 32 Circuit Pass Through Box Period Lifetime ``'E= BUILDING HT: 2 STORY CPBF113 16 Circuit Pass Through Box tCPBF33 33 Circuit Pass Through Box` "8w MODULES: SMX-250P a€� CPBF17 17 Circuit Pass Through Box CPBF34 34 Circuit Pass Through Box E u< SYSTEM kv: 8.25 kW CPBF18 18 Circuit Pass Through Box CPSF35 35 Circuit Pass Through Box a E 5 MOUNTING MSI TILE HOOKS CPBF19 19 Circuit Pass Through Box CPBF36 36 Circuit Pass Through Box HARDWARE: r=z INVERTER: M215-60-2LL-S22-IG 9 0022.2oi3 �iEE�C:t- 1 AHJ: LAKE ELSINORE +t6FotrlC SHEET NUMBER: E20 M KI SOLAR MAX RENEWABLE ENERGY PROVIDER INC 3080 12TH STREET, CR 140130CA I O:112 RIVERSIDE,CA 92507 CROSSRAIL MOUNTING SYSTEM EVALUATION Jan 30, 2013 0 PAGE 2 OF 3 TEL: (951)300-0788 CR1=10130CA10:112 FAX: (951)213-3099 CLASS#C-46 LIC#972048 Jan 30,2014 CONFIDENTIAL-THE INFORMATION applicable sections of the 2013 CBC. For designated Case Study areas noted in the 2013 Triennial HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE Everest Solar Systems,LLC moment; Edition of Title 24,California Code of Regulations,refer to local jurisdiction requirements for snow EXCEPT SOLARMAX RENEWABLE ENERGY PROVIDER INC.,NOR SHALL 3809 Ocean Ranch Blvd,Suite 111 and wind load determination. Seismic criteria were not considered per provisions of ASCE 7 10 I PART TOOTHERS OUTSIDE TTHH WHOLE ORE Oceanside,CA 92056 c c RECIPIENT'S ORGANIZATION,EXCEPT IN Attn:Andy 1Veshat - e Section 13.1.4. CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARMAX EQUIPMENT,WITHOUT THE WRITTEN PERMISSION OF SOLARMAX RE: CrossRail PV Panel Mounting System Evaluation Loading Parameters: RE WABIE ENERGY PROVIDER INC. o Ground snow load:Varies To whom it may concern: o Ultimate 3-second gust wind speed(V)=110-170 mph ROBERT LIU o Building roof mean height:30 ft.or less LIC. HOLDER'S SIG. Per your request,Moment Structural Engineering Group has performed a comprehensive structural o Roof wind pressure region:Zone 1-Zone 3 analysis of the Everest Solar CrossRail Solar PV Mounting System for typical installations in the o Structural risk category:11 g ry: State of California. When installed per the conditions and design criteria described herein,the o Wind exposure: B,C,D CrossRail Solar PV Mounting System is compliant with the sections of the design reference o Panel orientation:Portrait or Landscape documents noted below. o Panel installation angle:Flush with roof slope o Roof slope(0):Varies Design Reference Documents 0 2013 Triennial Edition of Title 24,California Code of Regulations Z Based on 2012 International Building Code&2012 International Residential Code Design Results W o o ASCE/SEI 7-10-Minimum Design Loads for Buildings and Other Structures The allowable span lengths of the system are principally controlled by applicable wind (speed, o J LO 0 2010 Aluminum Design Manual,by the Aluminum Association exposure,pressure zone)and snow loads to the structure. Refer to the CrossRail span tables in the °W J o Section and materials data provided by Everest Solar Systems appendix to this document for recommended rail configurations based on combinations of these N N v > U ■ Rail section properties appear in Table 25 of this report loading parameters. The reaction loads provided in the attached tables are only applicable when Q Q LLj used with the span length recommendations provided herein. U)o N O �o M> Z Overview o a C Cl) W a. The CrossRail PV-panel roof mounting system consists of extruded aluminum support rails,module Installation Notes a o O - W clamps,attachments,and fasteners spanning between points of attachment on an existing roof The following guidelines apply to all installations using the CrossRail product line: �/ structure. Attachment of the CrossRail Mounting System to the existing roof structure shall be the . Tables assume two independent support rails per panel with portrait orientation,or shared Q responsibility of the installer,and should be analyzed by a registered design professional where intermediate rails with panels in landscape orientation. required by the local authority having jurisdiction. . Maximum end cantilever of aluminum support rail shall not exceed one-third (1/3) of allowable span in the roof wind pressure zone of the cantilever Rails shall be continuous(not spliced)over a minimum of two supports U Methods&Design Parameters . Installations over roof overhangs or within 10"of any roof edge is not advised W Applicable combinations of dead,wind,and snow loads were evaluated in accordance with current . Observe all local jurisdictional requirements regarding roof setback requirements 0 code requirements to determine allowable rail span lengths, based on assumptions of single-span conditions and allowable deflection of L/120. DRAWN BY: EH DATE: 5-14-14 Design wind pressures were determined using Components and Cladding calculations in Chapter MARKET: RESIDENTIAL 26-30 of ASCE 7-10, using the loading parameters listed below. Configurations not conforming to BUILDING HT: 2 STORY these parameters will require additional analysis. Calculation of applicable roof snow load should MODULES: SMX-250P be based upon ground snow load maps and equations and factors of ASCE 7-10, Chapter 7 and SYSTEM kV: 8.25 kW moment STRUCTURAL ENGINEERING GROUP,LLC. MOUNTING HARDWARE: 10530 Warwick Ave,Suite C5•Fairfax,VA 22030•Phone:703-998-23500 Web:www.msegile.com moment STRUCTURAL ENGINEERING GROUP,LLC. MSt TILE HOOKS 10530 Warwick Ave,Suite C5 0 Fairfax,VA 22030•Phone:703-988-23500 Web:www.msegllc.com INVERTER; M215-60-2LL-S22-IG AHJ: LAKE ELSINORE SHEET NUMB ER: E 2 j Solar MAC 3— -- 7 SOLAR MAX RENEWABLE Z._._— ..J._____ --- - ._.---.. .__.._--- —__.___._...— ENERGY PROVIDER INC 3080 12TH STREET, 9 RIVERSIDE,CA 92507 TEL: (951)300-0788 __ CROSSRAIL MOUNTING SYSTEM EVALUATION Jan 30, 2013®PAGE 3 OF 3 FAX: (951)213-3099 A CLASS#C-46 LIC#972048 000, CONFIDENTIAL-THE INFORMATION FR HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE _ EXCEPT SOLARMAX RENEWABLE ENERGY PROVIDER INC..NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE \ RECIPIENT'S ORGANIZATION,EXCEPT IN R �J CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOIARMAX W EDUIPMENT,WITHOUT THE WRITTEN RMAX Summary --__..___ PERMISSION OF SOL MDER RENEWABLE ENERGY PRONDER INC. This assessment has provided design validation for code-compliant installations of the CrossRail PV Mounting system in the State of California. For the configurations and design loadings noted 6(_ �1 L�— previously,the attached span tables represent maximum span lengths based on allowable stresses ROBERT LIU and deflection criteria.For all other configurations,refer to Everest Solar Systems for engineering _ - LIC. HOLDER'S SIG. I support. _ - --- -- This report does not provide analysis of any existing structures, as may be required by the local authority having jurisdiction. D 01* We appreciate the opportunity to have assisted you with this project. Should you have any further - - i questions regarding this analysis,please feel free to contact us by phone or email. CI�MILEA/ER �' OF NI.hX SIRNN. W o Best Regards F- 3� J LO '�FESS/ �� "� —� -'FR pN Stainless Steel Hex Bolt W O pTR Ck } N w U o > v} Lu W� o'( 95 Cxp. 12-31 -tLi ` Aluminum Everest Solar Mid Clamp o M z CIVIL \\�% j oa �o W iTfir)� .. ... I o a � W - I Stainless Steel Everest Solar MK2 0-0 � Q Shawn P.Kelleyy., P.E. � e Principal Aluminum Everest Solar CrossRail 48 moment STRUCTURAL ENGINEERING GROUP,LLC. i w)hdle Z 'se 1lc�.eo 11 Aluminum Everest Solar CrossRail 48 Hi U w Max span of 72"given the following apply: i O I t1 ASCE 7-10/CBC 2013 Up to 120mph Wind Speed EH -Up to 10lbs Snow Load DRAWN BY: Roof Wind Pressure Zone 1 5-14-14 Exposure B and C DATE'. -7°-27°Roof Pitch MARKET: RESIDENTIAL Check with local building department or AHJ for site specific requirements DAIA SHF I. BUILDING HT: 2STORY Everest Solar S sterns, LLC " LT JH.a 09 CiCF3r„_ Pu rnch Blvd. Suite, 111 Ch��c'�;A, �I� \�F��, h/-\��. SPAN __.1 MODULES: SMX-250P OCEOIISIC,e, �;�� 9COJ6 -_.. _....TILL DIA�[.NSIONS SYSTEM kV: 8.25kW st�r3Y s PARI MBrR: N/.A INCHES 1I,W] MOUNTING MSI TILE HOOKS NI F- N/A HARDWARE: ~ lr alEd LJL 20140422 MATERIAL: �UIUII U6ARI-'JCE �UtJk3CR'IITT(D111@I1�S'rRUCTURALENGiNEER1NGGROUP,LLC. stiEET 1 of I NVERTER: M215-60-2LL•S22-IG Rclea,e L rL 20 40424 FINSH P�t�:it{ SCALE: 1 4 SERIES. PARTS 10530 Warwick Ave,Suite C5 Fairfax,VA 22030®Phone:703-9IIII-23500 Web:www.Tnsegltc.com LAKE ELSINORE Tlis drarnng I• the sole pir.perty of Everest Solar System>, LLC. Ir �s prole�lcd ay wpyrgnt and moy only be(opicd iepiodur.ed or aismbuted to o third puny xth u.Pli, pennisslor� AHd: SHEET NUMBER: E22 Solar /ULAX,I) SOLAR MAX RENEWABLE ENERGY PROVIDER INC 3080 12TH STREET, RIVERSIDE,CA 92507 TEL: (951)300-0788 FAX: (951)213-3099 CLASS#C-46 LIC#972048 __ _ ___....__.. ...............____. ---_.-- .___.--- _...._.... _.---...__ . CONFIDENTIAL_ THE IN70RMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARMAX RENEWABLE ENERGY PROVIDER INC.,NOR SHALL IT BE'rl T - --- rn --"-� ._.. -- �_ ._...-- r -"-- _ --"- Cam_-- L,> CIE DISCLOSED IN WHOLE OR RJ PART TO OTHERS OUTSIDE THE _ RECIPIENYS ORGANIZATION,EXCEPT IN - - CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE AX 130.5 EQUIPMENT,WTHOUT THE WRITTEN -- - PERMISSION OF SOLARMAX =- v 100.3 EWABLE ENER Y PROVIDER INC. A eo - 70.2 40 98 ROBE LIU ' m fir ' ' � ✓ LIC. HOLDER'S SIG. Ln 124,2foo o - , Am 140.3 Ci 20.4 49.7 49.7 20.5 8.7 24.3 17.6 4.2 iP�) n _ J o ROOF HOOK DETAIL ' M "� o Cl) _ SCALE:N.T.S. (` ., _ N.'? 7 I W 2 j \ Tn IW- -----,ROOF HOOK-PLATE DETAIL � O � W U C o > W G d 15 1 } ------- —_____.___ / ® DETAIL DESCRIPTION BOLTED CONNECTION o o O - ---- --- uWx h MJ ,n I o c N Ln oo� 87� C' C R GE BOLT 8116-18x1 00. W K CC a-o O Y _ HFJ(NUT -I M Copyright©2012 Mounting Systems Inc.West Sacramento e field of application acceptable tolerance surface scale / weight SLOTTED HOLE DETAIL ° Verwendungsbereich Zul.Abw. Oberfl. MaRstab_...._.. 1 .2 \21) Gewicht A SG E:N.TS. �� __..__ i- material,semifinished product �y general tolerance Werkstoff,Halbzeug Allgemeintoleranz mill finished DIN ISO 2768-m pressblank date name U 1 �L SLOTTED HOLE fi DETAIL_ _ _ Datum Name W 09 \'��SCALE N.1.5. 0 drawer 4.17.12 NDI CALIF. RH 0q checked n 4 _ _-__--- Engineering TWO WAY ADJUSTABLE DRAWN BY. EH DATE 5-14-14 ao I sheet LOWER HOLE DETAIL___ _--_—_. ��+` Blatt MARKET: RESIDENTIAL ��;SfALE:N.T.S. .'r Mounting Systems Inc 805_0072 820 Riverside Parkway A4 2 STORY mounting West Sacramento,Ca BUILDING HT: status modification date name ss,ten's replacement for replaced by Zust. Anderun I Datum Name Ersatz fur Ersetzt Burch _.___.. „- ... MODULES: SMX-250P SYSTEM kV: 8.25 kW MOUNTING HARDWARE: MSI TILE HOOKS INVERTER: M215-60-2LL-S22-IG AHJ: LAKE ELSINORE SHEET NUMBER: E23 Solar MAX SOLAR MAX RENEWABLE ENERGY PROVIDER INC 3080 12TH STREET, RIVERSIDE,CA 92507 TEL: (951)300-0788 "U N I RAC Installation Manual 205.4 TLH High Profile Leg Kit SolarMount FAX: (951)213.3099 CLASS#C-46 LIC#972048 SO T^+ CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHAH NOT BE USED FOR THE BENEFIT OF ANYONE MMA&RMOUE EXCEPT SOLARMAX RENEWABLE ENERGY PROVIDER INC.,NOR SHALL TLH High Profile Tilt Legs R \ 6(from de bolt head set) S(from rail s rail CI IE DISCLOSED IN ION,WHO E OR N \ PART TO OTHERS OUTSIDE THE (from rail set) RECIPIENT'S WTH THE SAL EXCEPT IN Installation Supplement 205.4 x into rail slot CONNECTION WITH THE SALE AND USE s of THE RESPECTIVE HE WRITTEN i �-- -6(from your rail set) \, \ EQUIPMENT,NI71i0UT THE WRI1lEN 3r `y slide bolt head 3e PERMISSION OF SOLARMAX U.S.Des.Paten(No.D196,2485,D496,2495.Other patents pending. � �.;, into rail slot RENEWABLE ENERGY PROVIDER INC. -� FIXED LEG Leg strut ROBERT LI� j' (Special order) LIC. HOLDER'S SIG. *y` ADJUSTABLE Leg strut 4 LEG � r 5 2 6(from rail set)-3- s�r� j ' �i Leg tube a FOOT 3 2 f o j,/ Drill 3/8"bolt hole / �� for easier seasonal • �`� .� adjustment. ' L-foot (from NOW 3e • 1 ail set)r W p • L-fool (from�3m ,'' 5 x� _ M ail set) LO N° J N co rn • w`ter' OCC N W Q Adjustable leg parts list G Q Oj _ Q rn Quantity Adjustable Leg Cross Section o "' N Tn O Thank you for purchasing a Unirac.Please review this manual thoroughly before installing Wrench Recommended your SolarMount system. • Part 2-leg kits 4-leg kits size torque((t-Ibs) °o Q M( Z The installer is solely responsible for: Leg tube 2 4 o a O W Leg strut 2 4 J W • Complying with all applicable local or national building codes,including any that may X a O W supersede this manual; 1.Bolt,'/a x 3" 2 4 '!Id' 15 0-0 Q 2.Bolt,'/a x I''/a" 2 4 '/16 15 Fixed leg parts list(per pair of legs) to • Ensuring that Unirac and other products are appropriate for the particular installation 3.Flange nut,'/e" 2 4 '/IM1' 15 Wrench Recommended and the installation environment; 4.Strut nut,IN' 2 4 Part Quantity size torque(ft-Ibs) • Ensuring,in roof applications,that the roof,its rafters,connections,and other 5.Fender washer,'/a' 4 8 structural support members can support the array under building live load conditions; 6.Bolt,'/a x'/4" 4* 8t 'h4' 15 Leg strut I • Using only Unirac parts and installer-supplied parts as specified by UniRac(substitution *From your rail set 2.Bolt,'/a x I'A" 2 '/16" 15 of parts may void the warranty); f 6 from your rail set;2 from your leg kit 3.Flange nut,%" 2 '/'6" 15 • Ensuring that lag screws have adequate pullout strength and shear capacities as b.Bolt'/e x'/4' LLJ U installed; (from your rail set) 4 'lie" 15 � • In roof applications,maintaining the waterproof integrity of the roof,including — O selection of appropriate flashing;and • Ensuring safe installation of all electrical aspects of the PV array. DRAWN BY: EH Caution:Stainless steel hardware can seize up,a process called galling.To significantly ca ® reduce the likelihood of galling,sAr-T-tze anti-seize lubricant has been included with DATE: " Pub �' your hardware.Apply a very small drop to the threads of all bolts before installa- ® tion. If more anti-seize is needed,substitute any lubricant. MARKET: RESIDENTIAL BUILDING HT:No 'AC2 STORY A HILTI GROUP COMPANY MODULES: SMX-250P Unirac welcolncs input concerning the accuracy and user-friendliness of this publication.please write to publicationsC'uniraccmn. 2, SYSTEM kV: 8.25 kW MOUNTING HARDWARE: MSI TILE HOOKS INVERTER: M215-60-2LL-S22-IG AHJ: LAKE ELSINORE SHEET NUMBER: E24 Soar' AUX'," SOLAR MAX RENEWABLE ENERGY PROVIDER INC 3080 12TH STREET, RIVERSIDE,CA 92507 TEL: (951)300-0788 SolarMount Installation Manual 205.4 TLH High Profile Leg Kit C:°U N I RAC ®:'U N I RAC Installation Manual 205.4 TLH High Profile Leg Kit SolarMount FAX: (951)213-3099 CLASS#C-46 LIC#972048 CONFIDENTIAL-THE INFORMATION Spacing of Footing Bolts HEREIN CONTAINED SHALL NOT BE 10 year limited Product Warranty,5 year limited Finish Warranty USED FOR THE BENEFIT OF ANYONE and L-Feet for Each Rail(inches) _ EXCEPT SOLARMAX RENEWABLE Unirac,Inc.,warrants to the original urchaser the practices specified b AAMA 609&610-02 If within the specified Warranty periods the ENERGY PROVIDER INC.,NOR SHALL 15 percent of rail length Use this table in conjuction with Figure 3 or Figure 4 to determineP P P Y P h'P IT BE DISCLOSED IN WHOLE OR IN footing bolt and L-foot spacing for your SMR Rail Set. ("Purchaser")of product(s)that it manufactures -"Cleaning and Maintenance for Architecturally Product shall be reasonably proven to be PART TO OTHERS OUTSIDE THE ("Produce)at the original installation site that Finished Aluminum"(wwwaamanet.org)are not defective,then Unirac shall repair or replace the RECIPIENT'S ORGANIZATION,EXCEPT IN Rail Length70%Rail Length CONNECTION PATH THE SALE AND USE the Product shall be free from defects in material followed by Purchaser.This Warranty does not defective Product,or any part thereof,in Unirac's OF THE RESPECTIVE SMARMAX SMR4$ 48 34 and workmanship for a period of ten(10)years, cover damage to the Product that occurs during sole discretion.Such repair or replacement shall EQUIPMENT,WITHOUT THE WRITTEN SOLARMAX SMR60 60 42 except for the anodized finish,which finish its shipment,storage,or installation. completely satisfy and discharge all of Unirac's PERMISSION OF PROVIDER 45 percent P g P y �" g RENEWABLE Y PROVIDER INC. p SMR72 72 50 shall be free from visible peeling,or cracking or This Warranty shall be VOID if installation of liability with respect to this limited Warranty. SMR84 84 59 chalking under normal atmospheric conditions the Product is not performed in accordance Under no circumstances shall Unirac be liable SMR96 96 67 for a period of five(5)years,from the earlier for special,indirect or consequential damages - with Unirac's written installation instructions, SMR 106 106 74 of I)the date the installation of the Product is or if the Product has been modified,repaired, arising out of or related to use by Purchaser of ROBERT LIU ," \ 40%Rail 45%Rail completed,or 2)30 days after the purchase of the Product or reworked in a manner not previously . LIC. HOLDERS SIG. Rai/LengthLengt i Length the Product by the original Purchaser("Finish authorized by Unirac IN WRITING,or if the Manufacturers of related items,such as PV 40 percent Warranty"). SMR 120 120 48 54 Product is installed in an environment for which modules and flashings,may provide written SMR 120 120 53 54 The Finish Warranty does not apply to any it was not designed.Unirac shall not be liable warranties of their own.Unirac's limited 45 percent - foreign residue deposited on the finish.All for consequential,contingent or incidental Warranty covers only its Product,and not any \ ,ad SMR144 144 58 65 SMR 156 156 62 70 installations in corrosive atmospheric conditions damages arising out of the use of the Product by related items. SMR 168 168 67 76 are excluded.The Finish Warranty is VOID if Purchaser under any circumstances. 40 percent SMRI80 180 72 81 L \_I Z Figure 4.Leg spacing with SolarMount SMR120 to 132 rail sets(two legs per rail). W p 3� J Cl) mo J N N LL wt~n O 04 W Q �30 percent of rail length W< r2n 1 Q W Figure 3.Leg spacing with SolarMount SMR48 to }O "' N in O 106 rail sets(one leg per rail). to 0 M> Z 00 -j rOM W 70 percent 0? W a0 O Y -9 N 0 J 7 rceni Q H U W O DRAWN BY: EH DATE: 5-14-14 MARKET: RESIDENTIAL ®® 1411 Broadway Boulevard NE BUILDING HT: 2STORY ®® U N I R"AC® Albuquerque NM 87102-1545 USA MODULES: SMX-250P 3 4 SYSTEM kV: 8.25 kW MOUNTING HARDWARE: MS TILE HOOKS INVERTER: M215-60-2LL-S22-IG AHJ: LAKE ELSINORE SHEET NUMBER: E25