HomeMy WebLinkAboutItem No. 01 - Planning Application No. 2021-25 (Jack in the Box El Toro)
Page 1 of 5
REPORT TO PLANNING COMMISSION
To:Honorable Chair and Members of the Planning Commission
From:Damaris Abraham, Interim Assistant Community Development Director
Prepared by:Kevin Beery, Associate Planner
Date:February 21, 2023
Subject:Planning Application No. 2021-25 (Jack in the Box El Toro) - A request
for approval of a Commercial Design Review and two Conditional Use
Permits to construct and operate two drive-through restaurants (2,649 sq. ft.
and 624 sq. ft., respectively) located at the intersection of Highway 74 and El
Toro Cut Off Road
Applicant:Gabriela Marks, Marks Architects
Recommendation
1. Find and determine that the project is exempt from the California Environmental Quality
Act (CEQA) pursuant to CEQA Guidelines Section 15332 (In-Fill Development Projects);
2. Adopt A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF LAKE
ELSINORE, CALIFORNIA, ADOPTING FINDINGS THAT PLANNING APPLICATION NO.
2021-25 (CONDITIONAL USE PERMIT NO. 2022-01, CONDITIONAL USE PERMIT NO.
2022-04 AND COMMERCIAL DESIGN REVIEW NO. 2022-01) IS CONSISTENT WITH
THE WESTERN RIVERSIDE COUNTY MULTIPLE SPECIES HABITAT
CONSERVATION PLAN;
3. Adopt A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF LAKE
ELSINORE, CALIFORNIA, APPROVING CONDITIONAL USE PERMIT NO. 2022-01 TO
ESTABLISH A 2,649 SQUARE-FOOT DRIVE-THROUGH RESTAURANT AT APNS: 347-
130-033 and 347-130-034;
4. Adopt A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF LAKE
ELSINORE, CALIFORNIA, APPROVING CONDITIONAL USE PERMIT NO. 2022-04 TO
ESTABLISH A 624 SQUARE-FOOT DRIVE-THROUGH RESTAURANT AT APN: 347-
130-035; and
PA 2021-25 (Jack in the Box El Toro)
PC: 02/21/2023
Page 2 of 5
5. Adopt A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF LAKE
ELSINORE, CALIFORNIA, APPROVING COMMERCIAL DESIGN REVIEW NO. 2022-01
PROVIDING BUILDING DESIGN AND RELATED IMPROVEMENTS FOR TWO DRIVE-
THROUGH RESTAURANTS AT APNS: 347-130-033, 347-130-034 and 347-130-035.
Project Location
The project site is located on the northwest side of Highway 74, southeast of North Frontage Road
and bisected by El Toro Cut Off Road in the Ramsgate Specific Plan. (APNs: 347-130-033; 347-
130-034; 347-130-035)
Environmental Setting
EXISTING LAND USE GENERAL PLAN ZONING
Project Site Vacant Ramsgate Specific Plan Commercial
North Commercial/Industrial County of Riverside County of Riverside
South Commercial/Industrial County of Riverside County of Riverside
East Single-Family Residential Ramsgate Specific Plan Medium Density Residential
West Single-Family Residential County of Riverside County of Riverside
Project Description
Planning Application No. 2021-25 is a request for a Commercial Design Review (CDR No. 2022-
01) to construct two drive-through restaurants and related site improvements on adjacent parcels.
The application also includes a request for a Conditional Use Permit (CUP No. 2022-01 and CUP
No. 2022-04) to allow operation of each proposed drive-through, as required by the Ramsgate
Specific Plan Commercial zoning regulations.
Jack in the Box
The application proposes to construct a one-story, 2,649 square-foot Jack in the Box drive-
through restaurant on the approximately 1.10-acre parcel to the south of El Toro Cut Off Road.
The building would be constructed together with related onsite improvements including a drive-
through lane with 13 queuing spaces, 30 parking spaces and landscaping. The proposed
restaurant is rectangular in plan and is centrally sited in the north portion of the site. Primary
access to the site would be provided by a full movement driveway along Frontage Road in the
northwest portion of the site, and secondary access would consist of a restricted (right-in/right-
out) two-way driveway in the southeast portion of the site connecting to Highway 74.
The Human Bean
The application also proposes to construct a one-story, 624 square-foot The Human Bean (THB)
drive-through coffee stand on the approximately 0.37-acre parcel to the north of El Toro Cut Off
Road. The building would be constructed together with related onsite improvements including a
drive-through lane with eight queuing spaces, eight parking spaces and landscaping. The
proposed restaurant is rectangular in plan and is centrally sited in the south portion of the site.
Access to the site would be provided by a full movement driveway along Frontage Road in the
northwest portion of the site.
PA 2021-25 (Jack in the Box El Toro)
PC: 02/21/2023
Page 3 of 5
Off-Site Improvements
Project construction will also involve off-site infrastructure improvements including half-width right-
of-way improvements along the project boundaries and installation of a traffic signal at the
intersection of Highway 74 and El Toro Cut Off Road. Project construction would also involve
utility work including construction of a public sewer main along the west frontage of the site in
addition to water main, electrical and gas line extensions serving the new buildings.
Analysis
Specific Plan Consistency
The project site is located in the Ramsgate Specific Plan and has a land use designation of
Commercial. This designation is primarily intended to accommodate a shopping area that
provides convenience goods and services for the residential neighborhoods. According to Section
9.2 of the Ramsgate Specific Plan, fast food restaurants including drive-through establishments
are permitted subject to approval of a Conditional Use Permit.
Staff has reviewed the submitted development plans for compliance with the Commercial
development standards and regulations of Section 9.2 of the Ramsgate Specific Plan and the
parking requirements under Chapter 17.148 of the Lake Elsinore Municipal Code (LEMC). The
proposed development conforms to applicable standards as shown in Tables 2 and 3.
Commercial Development Standard Required Proposed
Floor Area Ratio (FAR)0.75 max.Jack: 0.05
THB: 0.04
Maximum Building Height 35'-0"Jack: 22'-8"
THB: 19'-6"
Building Setback, from street 20'-0" min.Jack: 34'-5"
THB: 20'-0"
Parking Area Setback, from street 20'-0" min.Jack*: 4'-10"
THB*: 4'-10"
Landscaping Coverage 10% min.Jack: 45.8%
THB: 24.8%
*Alternate development standards proposed pursuant to Ramsgate Specific Plan Section 9.2
Parking
Requirements
Required Proposed
Drive-Through Storage 8 vehicles min.Jack: 13 vehicles
THB: 8 vehicles
Required number of
parking spaces
1 per 45 s.f. customer area
+ 1 per 200 s.f. non-
customer area
Jack: 930/45 + 1,719/200 = 30
Provided: 30
THB: 180/45 + 624/200 = 8
Provided: 8
Pursuant to Ramsgate Specific Plan 9.2, alternative development standards may be requested
for commercial developments where it can be shown the project will better serve the public
PA 2021-25 (Jack in the Box El Toro)
PC: 02/21/2023
Page 4 of 5
interest. The applicant is proposing a reduction from the standard 20-foot parking area setback
located along the perimeter of The Human Bean site as well as the parking area setback located
along Frontage Road on the Jack in the Box site. The public interest will be better served by the
project through these alternative developments because it will enable commercial development
to provide two new convenient eating options for residents and, moreover, the project provides
surplus landscaping coverage and screening measures to avoid visibility impacts resulting from
the reduced setbacks. Therefore, approval of the requested project-specific alternative standards
will not compromise the visual quality of the area and will allow commercial development of the
property in alignment with the goals and policies of the Ramsgate Specific Plan.
Architecture and Site Design
The architectural design of the proposed buildings complies with the Nonresidential Development
Standards (Chapter 17.112) of the LEMC. The proposed Jack in the Box building is rectangular
in plan and will feature a flat roof with cement accent panels on the parapet. The main body of
the building exterior would consist of dark red cement plaster, brown textured porcelain accent
tiles, metal awning projections, aluminum-framed doors and windows with clear glass, and space
for tenant wall signage. The proposed The Human Bean building is rectangular in plan and will
feature a flat roof with a parapet capped with gray aluminum coping. The main body of the building
exterior would consist of tan and dark blue cement plaster, stone veneer wainscoting, metal
awning projections, aluminum-framed doors and windows with clear glass, and space for tenant
wall signage. The exterior architecture, including colors and materials, has been designed to be
harmonious and compatible with surrounding development. Furthermore, the proposed
landscaping improvements complement the proposed building design, provide shade and break-
up expanses of pavement. The proposed site design is cohesive and functional for the proposed
use.
Traffic and Operations
A traffic impact analysis dated August 1, 2022 was prepared by Trames Solutions Inc. for the
project. The purpose of the analysis is to assess the degree to which the project would impact
performance of the surrounding road network, specifically the intersections of the proposed
project driveways along Frontage Road and High 74, as well as the existing intersections of
Highway 74 and El Toro Cut Off Road, Frontage Road and Rosetta Canyon El Toro Cut Off Road,
Highway 74 and Rosetta Canyon Drive, and Highway 74 and Crater Drive. The analysis
concluded that upon construction of half-width right-of-way improvements abutting the site,
construction of a new traffic signal at the intersection of Highway 74 and El Toro Cut Off Road,
and payment of a 1.5 percent fair share contribution to a new traffic signal at Highway 74 and
Crater Drive, the project would not adversely affect levels of service in the study area and that the
study intersections would function at satisfactory levels of service.
Furthermore, the drive-through operations are not anticipated to cause significant traffic impacts
on the surrounding roadways. According to the traffic impact analysis, based on survey data of
the other tenant locations in the region, the study determined that the proposed drive-through
stack capacities are sufficient to accommodate peak queue length. However, in case of drive-
through overflow, there is additional queuing area behind the drive-through entrance. The Jack in
the Box drive-through is designed to accommodate up to 13 vehicles, and up to six additional
vehicles can be stacked behind the drive-through entrance. The Human Bean drive-through is
PA 2021-25 (Jack in the Box El Toro)
PC: 02/21/2023
Page 5 of 5
designed to accommodate up to 8 vehicles, and up to three additional vehicles can be stacked
behind the drive-through entrance. The applicant has also submitted queuing management plans
detailing procedures and operational measures to be implemented to achieve safe parking lot
circulation during peak drive-through demand. Therefore, upon implementation of the circulation
improvements and traffic management plans required by conditions of approval, the project is
consistent with the circulation goals and policies of the General Plan and is not expected to
adversely impact the safety or efficiency of the surrounding roadways.
Environmental Determination
CEQA
The proposed project is exempt from the California Environmental Quality Act (Cal. Pub. Res.
Code §§21000 et seq.: “CEQA”) and the CEQA Guidelines (14 C.C.R. §§ 15000 et seq.) pursuant
to CEQA Guidelines Section 15332 (New Construction) because the project (a) is consistent with
the applicable general plan designation and all applicable general plan policies as well as with
applicable zoning designation and regulations, (b) the site of the proposed development is within
city limits on a project site of less than five acres substantially surrounded by urban uses, (c) the
project site has no value as habitat for endangered, rare or threatened species, (d) the project will
not result in any significant effects relating to traffic, noise, air quality, or water quality, and (e) the
site can be adequately served by all required utilities and public services. A categorical exemption
checklist documenting project eligibility for the Class 32 exemption is attached to this report
(Attachment 1).
MSHCP
Approximately 2.42 acres of the project site are located in the southern portion of Criteria Cell
4076 within Cell Group X, which is in MSHCP Elsinore Area Plan, Subunit 3 (Elsinore). Therefore,
on January 12, 2022, a formal and complete Lake Elsinore Acquisition Process (LEAP)
application, LEAP 2022-02 was submitted to the City. On June 16, 2022, the Western Riverside
County Regional Conservation Authority (RCA) concluded its Joint Project Review (JPR) finding
that the project is consistent with both the Criteria and Other Plan requirements. On July 6, 2022,
the California Department of Fish and Wildlife and the U.S. Fish and Wildlife Service concurred
with the JPR findings. Therefore, the project is consistent with the Western Riverside County
Multiple Species Habitat Conservation Plan (MSHCP).
Attachments
Attachment 1 – Class 32 CEQA Exemption Checklist
Attachment 2 – MSHCP Resolution
Attachment 3 – CUP Resolution Jack in the Box
Attachment 4 – CUP Resolution The Human Bean
Attachment 5 – CDR Resolution
Attachment 6 – Conditions of Approval
Attachment 7 – Vicinity Map
Attachment 8 – Aerial Map
Attachment 9 – Design Review Package
JACK IN THE BOX EL TORO
PLANNING APPLICATION NO. 2021-25
Commercial Design Review No. 2022-01
Conditional Use Permit No. 2022-01
Conditional Use Permit No. 2022-24
CLASS 32 CATEGORICAL EXEMPTION CHECKLIST
Prepared By:
CITY OF LAKE ELSINORE
130 South Main Street
Lake Elsinore, CA 92530
Applicant:
MARKS ARCHITECTS
2643 Fourth Avenue
San Diego, CA 92103
Project Location:
Highway 74 & El Toro Cut Off Road
APNs:
347-130-033, 347-130-034, 347-130-035
February 2023
Jack in the Box El Toro Class 32 Categorical Exemption Checklist -
Page 2 of 18
SURROUNDING LAND USES AND SETTING
The project area consists of three parcels between State Route 74 and Frontage Road
composing two adjacent parcels located on opposite sides of El Toro Cut Off Road, which
bisects the project area. (APNs: 347-130-033, 347-130-034, 347-130-035). Surrounding land
uses include industrial to the north (unincorporated Riverside County), single-family residential
to the west (unincorporated Riverside County), industrial to the south (unincorporated Riverside
County), and single-family residential to the east (across Highway 74). The location and
boundaries of the project area are depicted in Figure 1.
PROJECT DESCRIPTION
The project involves a development proposal to construct and operate one 2,649 sq. ft. drive-
through restaurant on an approximately 1.09-acre site and one 624 sq. ft. drive-through coffee
stand on an approximately 0.39-acre parcel in conjunction with related on-site improvements
including parking spaces, landscaping, and minor utility extensions needed to serve the new
development. Project construction would also involve related off-site infrastructure improvements
including half-width right-of-way improvements along the project boundaries, installation of a
traffic signal at the intersection of Highway 74 and El Toro Cut Off Road, and construction of a
public 8" gravity sewer main along the property frontage on Frontage Road. The proposed total
area of disturbance including both on- and off-site improvements is approximately 3.76 acres.
GENERAL PLAN DESIGNATION: Specific Plan
ZONING: Ramsgate Specific Plan, Commercial (C)
Jack in the Box El Toro Class 32 Categorical Exemption Checklist -
Page 3 of 18
Figure 1 – Aerial Map
Jack in the Box El Toro Class 32 Categorical Exemption Checklist -
Page 4 of 18
Figure 2 – Vicinity Map
Jack in the Box El Toro Class 32 Categorical Exemption Checklist -
Page 5 of 18
Figure 3 – Site Plan (Jack in the Box)
Jack in the Box El Toro Class 32 Categorical Exemption Checklist -
Page 6 of 18
Figure 4 – Site Plan (The Human Bean)
Jack in the Box El Toro Class 32 Categorical Exemption Checklist -
Page 7 of 18
INFORMATION DEMONSTRATING THAT THE PROJECT SATISFIES THE CONDITIONS
DESCRIBED IN SECTION 15332 OF TITLE 14 OF THE CALIFORNIA CODE OF
REGULATIONS:
Criterion (a): Is the project consistent with the applicable general plan designation and all
applicable general plan policies as well as with applicable zoning designation and
regulations?
The project site is located in the Ramsgate Specific Plan area and has a land use designation of
C - Commercial. Commercial areas in the Ramsgate Specific Plan are primarily intended to
accommodate a shopping area that provides convenience goods and services for the residential
neighborhoods. Development of the commercial areas must comply with Ramsgate Specific Plan
Chapter 9.2 The project involves the proposed construction and establishment of two drive-
through restaurants. Fast food restaurants including drive-throughs are permitted subject to
approval of a use permit pursuant to Ramsgate Specific Plan Chapter 9.2. The development
proposal is therefore consistent with the applicable Specific Plan land use designation and
regulations according to the Ramsgate Specific Plan.
Criterion (b): Is the proposed development located within the City limits on a site of no
more than five acres substantially surrounded by urban uses?
The proposed development site is located within City limits and is approximately 1.47 acres in
area. The total area to be disturbed for on- and off-site improvements is approximately 3.76
acres. The project site is substantially surrounded by various urban uses as depicted in Figure
1.
Criterion (c): Does the project site have no value as habitat for endangered, rare, or
threatened species?
The following evaluation of existing on-site habitat for endangered, rare, or threatened species
is based on the project-specific Western Riverside County – MSHCP Consistency Analysis
Highway 74 – El Toro Cut Off Drive Thru Restaurant Final Report (Biological Report) dated
May 2022 prepared by Cadre Environmental (included as Appendix A). The findings contained
in the Biological Report are informed by both a literature review of the biological resources of
the project site and its vicinity, as well as a field survey performed on October 20, 2021. Of the
total 3.76 acres to be disturbed as a result of project implementation, approximately 3.26 acres
of the project area is characterized as “previously disturbed” whereas approximately 0.50 acres
is characterized as vegetated by Riversidean sage scrub.
As part of the study, the project site was assessed for its value as habitat for endangered, rare,
or threatened species, and was identified as having potential habitat (Riversidean sage scrub)
for six species considered endangered, rare, or threatened, including the Southern California
rufous-crowned sparrow, Bell’s sage sparrow, white-tailed kite, California horned lark,
loggerhead shrike, and coastal California gnatcatcher. However, according to the Biological
Report, these species are expected to occur onsite infrequently if at all. Furthermore, the extent
of removal of Riversidean sage scrub resulting from the project does not conflict with the
conservation goals for these species. Therefore, the project will comply with the requirements
in the Western Riverside County Multiple Species Habitat Conservation Plan (MSHCP), and the
project-specific conditions of approval will require the applicant to implement previously
approved mitigation requirements relating to species and habitat pursuant to the MSHCP.
Furthermore, the MSHCP identifies the project area as located in a special survey area for
Jack in the Box El Toro Class 32 Categorical Exemption Checklist -
Page 8 of 18
burrowing owl, and therefore special surveys were conducted to determine the presence of
suitable burrowing owl habitat. The survey concluded that no potential burrowing owl burrows
or other signs of the species actively occupying the site were observed. In order to avoid direct
take of any protected species and to comply with provisions of the MSHCP, project-specific
conditions have been added requiring that preconstruction surveys be performed to ensure the
site is void of burrowing owls prior to commencing site development activities. Additionally, the
project site is void of other significant habitat features, such as mature trees or riparian
features, that could serve ecological functions.
Additionally, the project was required to undergo the Lake Elsinore Acquisition Process (LEAP)
and Joint Project Review (JPR) procedures in order to determine whether the project area is
described for conservation purposes according to the MSHCP. In June 2022, the Regional
Conservation Authority (RCA) determined that none of the project area is proposed for habitat
conservation purposes. In July 2022, the California Department of Fish and Wildlife and the
U.S. Fish and Wildlife Service concurred with the findings of the JPR.
In conclusion, the project site has no considerable value as habitat for endangered, rare, or
threatened species. Although not required to mitigate a significant impact pursuant to CEQA,
the following permit conditions will be added to minimize the potential for impacts to biological
resources, and to comply with requirements of the MSHCP:
➢Due to the presence of potentially suitable habitat, a 30-day preconstruction survey for
burrowing owls is required prior to initial ground-disturbing activities (including
vegetation clearing, clearing and grubbing, tree removal, site watering, equipment
staging, grading, etc.) to ensure that no owls have colonized the site in the days or
weeks preceding the ground-disturbing activities. If burrowing owls have colonized the
project site prior to the initiation of ground-disturbing activities, the project proponent will
immediately inform the Regional Conservation Authority (RCA) and the Wildlife
Agencies, and will need to coordinate further with RCA and the Wildlife Agencies,
including the possibility of preparing a Burrowing Owl Protection and Relocation Plan,
prior to initiating ground disturbance. If ground-disturbing activities occur, but the site is
left undisturbed for more than 30 days, a pre-construction survey will again be
necessary to ensure burrowing owl has not colonized the site since it was last disturbed.
If burrowing owl is found, the same coordination described above will be necessary.
➢Pursuant to Section 6.1.4 of the MSHCP, applicant shall implement the following
measures as applicable:
i. Incorporate measures to control the quantity and quality of runoff from the site
entering the MSHCP Conservation Area. In particular, measures shall be put in
place to avoid discharge of untreated surface runoff from developed and paved
areas into MSHCP Conservation Areas. Best Management Practices (BMPs) will
be implemented to prevent the release of toxins, chemicals, petroleum products,
exotic plant materials, or other elements that might degrade or harm
downstream biological resources or ecosystems.
ii. Land uses proposed in proximity to the MSHCP Conservation Area that use
chemicals or generate bioproducts, such as manure, that are potentially toxic or
may adversely affect wildlife species, Habitat, or water quality shall incorporate
measures to ensure that application of such chemicals does not result in
discharge to the MSHCP Conservation Area. The greatest risk is from
landscaping fertilization overspray and runoff.
Jack in the Box El Toro Class 32 Categorical Exemption Checklist -
Page 9 of 18
iii. Night lighting shall be directed away from the MSHCP Conservation Area and
the avoided area on site to protect species from direct night lighting.
iv. Proposed noise-generating land uses affecting the MSHCP Conservation Area,
including designated avoidance areas, shall incorporate setbacks, berms, or
walls to minimize the effects of noise on MSHCP Conservation Area resources
pursuant to applicable rules, regulations, and guidelines related to land use
noise standards.
v. Avoid use of invasive, non-native plant species listed in Table 6-2 of the MSHCP
in approving landscape plans for the portions of the project that are adjacent to
the MSHCP Conservation Area, including avoidance areas. Considerations in
reviewing the applicability of this list shall include proximity of planting areas to
the MSHCP Conservation Areas and designated avoidance areas, species
considered in the planting plans, resources being protected within the MSHCP
Conservation Area and their relative sensitivity to invasion, and barriers to plant
and seed dispersal, such as walls, topography, and other features.
vi. Proposed land uses adjacent to the MSHCP Conservation Area shall
incorporate barriers, where appropriate, in individual project designs to minimize
unauthorized public access, domestic animal predation, illegal trespass, or
dumping into existing and future MSHCP Conservation Areas. Such barriers
may include native landscaping, rocks/boulders, fencing, walls, signage, and/or
other appropriate mechanisms.
vii. Manufactured slopes associated with proposed site development shall not
extend into the MSHCP Conservation Area.
viii. Weed abatement and fuel modification activities are not permitted in the
Conservation Area, including designated avoidance areas.
➢Pursuant to Appendix C of the MSHCP, the following best management practices
(BMPs), as applicable, shall be implemented for the duration of construction:
i. A condition shall be placed on grading permits requiring a qualified biologist to
conduct a training session for project personnel prior to grading. The training
shall include a description of the species of concern and its habitats, the general
provisions of the Endangered Species Act (Act) and the MSHCP, the need to
adhere to the provisions of the Act and the MSHCP, the penalties associated
with violating the provisions of the Act, the general measures that are being
implemented to conserve the species of concern as they relate to the project,
and the access routes to and project site boundaries within which the project
activities must be accomplished.
ii. Water pollution and erosion control plans shall be developed and implemented
in accordance with RWQCB requirements.
iii. The footprint of disturbance shall be minimized to the maximum extent feasible.
Access to sites shall be via pre-existing access routes to the greatest extent
possible.
iv. The upstream and downstream limits of projects disturbance plus lateral limits of
disturbance on either side of the stream shall be clearly defined and marked in
the field and reviewed by the biologist prior to initiation of work.
v. Projects should be designed to avoid the placement of equipment and personnel
within the stream channel or on sand and gravel bars, banks, and adjacent
upland habitats used by target species of concern.
vi. Projects that cannot be conducted without placing equipment or personnel in
Jack in the Box El Toro Class 32 Categorical Exemption Checklist -
Page 10 of 18
sensitive habitats should be timed to avoid the breeding season of riparian
species identified in MSHCP Global Species Objective No. 7.
vii. When stream flows must be diverted, the diversions shall be conducted using
sandbags or other methods requiring minimal instream impacts. Silt fencing of
other sediment trapping materials shall be installed at the downstream end of
construction activity to minimize the transport of sediments off site. Settling
ponds where sediment is collected shall be cleaned out in a manner that
prevents the sediment from reentering the stream. Care shall be exercised when
removing silt fences, as feasible, to prevent debris or sediment from returning to
the stream.
viii. Equipment storage, fueling, and staging areas shall be located on upland sites
with minimal risks of direct drainage into riparian areas or other sensitive
habitats. These designated areas shall be located in such a manner as to
prevent any runoff from entering sensitive habitat. Necessary precautions shall
be taken to prevent the release of cement or other toxic substances into surface
waters. Project related spills of hazardous materials shall be reported to
appropriate entities including but not limited to applicable jurisdictional city,
FWS, and CDFG, RWQCB and shall be cleaned up immediately and
contaminated soils removed to approved disposal areas.
ix. Erodible fill material shall not be deposited into water courses. Brush, loose
soils, or other similar debris material shall not be stockpiled within the stream
channel or on its banks.
x. The qualified project biologist shall monitor construction activities for the duration
of the project to ensure that practicable measures are being employed to avoid
incidental disturbance of habitat and species of concern outside the project
footprint.
xi. The removal of native vegetation shall be avoided and minimized to the
maximum extent practicable. Temporary impacts shall be returned to pre-
existing contours and revegetated with appropriate native species.
xii. Exotic species that prey upon or displace target species of concern should be
permanently removed from the site to the extent feasible.
xiii. To avoid attracting predators of the species of concern, the project site shall be
kept as clean of debris as possible. All food related trash items shall be enclosed
in sealed containers and regularly removed from the site(s).
xiv. Construction employees shall strictly limit their activities, vehicles, equipment,
and construction materials to the proposed project footprint and designated
staging areas and routes of travel. The construction area(s) shall be the minimal
area necessary to complete the project and shall be specified in the construction
plans. Construction limits will be fenced with orange snow screen. Exclusion
fencing should be maintained until the completion of all construction activities.
Employees shall be instructed that their activities are restricted to the
construction areas.
xv. The Permittee shall have the right to access and inspect any sites of approved
projects including any restoration/enhancement area for compliance with project
approval conditions, including these BMPs.
Criterion (d): Would the project result in any significant effects relating to traffic, noise,
air quality, or water quality?
I. Traffic
Jack in the Box El Toro Class 32 Categorical Exemption Checklist -
Page 11 of 18
The following review of potential traffic impacts is based on the Vehicle Miles Traveled (VMT)
Evaluation prepared by Trames Solutions Inc. dated January 18, 2023 (included as Appendix B)
for the project. The purpose of the VMT Evaluation is to assess the potential effects of the
project on the transportation system by estimating changes to vehicle miles traveled (VMT) per
capita. A summary of the VMT Screening Report is provided below:
•The project site is located within a low VMT-generating area
•The project is a local serving retail project proposing less than 50,000 square feet of
building area
Conclusion: The project would not significantly impact VMT per capita in accordance with the
City’s adopted Traffic Impact Analysis guidelines. Therefore, the project is presumed to have
less than significant VMT impacts because the project site is located within a low VMT-
generating area and the project is considered local serving in nature.
For additional information, refer to the VMT Screening Report included as Appendix B to this
report.
II. Noise
The following review of potential noise impacts is based on the Noise Assessment prepared by
Ldn Consulting, Inc. dated August 31, 2022 (included in Appendix C) for the project. Under
Appendix G of the State CEQA Guidelines, any project would create significant noise impacts if
the project would result in:
•Generation of a substantial temporary or permanent increase in ambient noise levels in
the vicinity of the project in excess of standards established in the local general plan or
noise ordinance, or applicable standards of other agencies;
•Generation of excessive groundborne vibration or groundborne noise levels; or
•Expose people residing or working in the project area to excessive noise levels if the
project is located within the vicinity of a private airstrip or an airport land use plan or,
where such a plan has not been adopted, within two miles of a public airport or public
use airport
The purpose of the Noise Assessment is to assess the potential noise impacts resulting from
project construction and operation and to evaluate whether the project would expose people to
excessive noise levels. A summary of the Noise Assessment is provided below:
•Project construction would not exceed the City’s construction noise standards.
Therefore, the project would not result in significant noise impacts from construction
activities.
•Project operation would not exceed the City’s exterior noise standards. Therefore, the
project would not result in significant noise impacts from operational activities.
Conclusion: Project construction would result in temporary noise impacts from transportation of
construction crews and equipment to and from the development site and construction activities
Jack in the Box El Toro Class 32 Categorical Exemption Checklist -
Page 12 of 18
such as operation of mobile and stationary construction equipment. However, any temporary
increases in ambient noise levels caused by construction would not exceed the City’s mobile
and stationary construction noise standards. Therefore, impacts from construction noise would
be less than significant. Although not required to mitigate any significant impacts under CEQA,
the City will require the project to comply with the following Conditions of Approval to minimize
noise from project construction in accordance with the recommendations provided in the Noise
Assessment:
➢During construction, the contactor shall ensure all construction equipment is equipped
with appropriate noise attenuating devices.
➢The contractor should locate equipment staging areas that will create the greatest
distance between construction-related noise/vibration sources and sensitive receptors
nearest the project site during all project construction.
➢Idling equipment should be turned off when not in use.
Project operation would result in ongoing noise generation caused by external speakers at the
drive-through lane and HVAC operations. However, project operation would not result in
significant increase in ambient noise levels from project operational activities given the project
setting and the proximity of the proposed development site to Highway 74. No significant
changes to ambient noise levels are expected as a result of existing ambient noise generated
by vehicle traffic along the highway. The noise levels caused by project operation would not
exceed the City’s exterior noise standards. Therefore, impacts from operational noise would be
less than significant.
For additional information, refer to the Noise Assessment included as Appendix C to this report.
III. Air Quality
The following review of potential air quality impacts is based on the Air Quality Assessment
prepared by Ldn Consulting, Inc. dated August 31, 2022 (included in Appendix D) for the
project. Under Appendix G of the State CEQA Guidelines, any project would create significant
impacts if a project would:
•Conflict with or obstruct implementation of the applicable air quality plan;
•Result in a cumulatively considerable net increase of any criteria pollutant for which the
project region is non-attainment under an applicable federal or state ambient air quality
standard;
•Expose sensitive receptors to substantial pollutant concentrations; or
•Result in other emissions (such as those leading to odors) adversely affecting a
substantial number of people
The purpose of the Air Quality Assessment is to assess the potential air quality impacts
resulting from project construction and operation and to evaluate project compliance with
applicable criteria pollutant thresholds set by the South Coast Air Quality Management District
(SCAQMD). A summary of the Air Quality Assessment is provided below:
Jack in the Box El Toro Class 32 Categorical Exemption Checklist -
Page 13 of 18
•Short-term emissions from project construction would fall below all applicable SCAQMD
local and regional daily thresholds of significance. Therefore, air quality emissions from
project construction, as well as cumulative impacts caused by project construction, are
less than significant.
•Emissions of all criteria pollutants from project operation fall below applicable daily
thresholds of significance. Therefore, the project would neither conflict with plans, violate
an air quality standard, nor contribute to an existing or projected violation, result in a
cumulatively considerable increase in ozone or particulate matter emissions or expose
receptors to substantial pollutant concentrations. Therefore, air quality emissions from
project operation are less than significant.
Conclusion: Project construction would result in emissions from equipment exhaust, fugitive
dust, and architectural coatings. Both regional and localized construction emissions from project
construction would fall below SCQAMD daily significance thresholds. Therefore, project
construction would not result in significant regional or localized air quality impacts.
Project operation would result in air quality impacts from increases in project trip generation,
electricity consumption, area sources, and evaporative emissions. Regional and localized
emissions from project operation would fall below SCQAMD daily significance thresholds.
Therefore, project operation would not result in significant regional or localized air quality
impacts.
Moreover, the project does not have the potential to expose sensitive receptors to substantial
pollutant concentrations, result in other emissions (such as those leading to odors) adversely
affecting a substantial number of people, or conflict with or obstruct implementation of any air
quality plan. In conclusion, the project would not result in any significant air quality impacts.
For additional information, refer to the Air Quality Assessment included as Appendix D to this
report.
IV. Water Quality
The project area is located within the Lake Elsinore sub-watershed of the Santa Ana Watershed
region of Riverside County. The Santa Ana Regional Water Quality Control Board (SARWQCB)
sets water quality standards for ground and surface waters within the region. Water quality
standards are defined under the Clean Water Act to include both the beneficial uses of specific
water bodies and the levels of water quality that must be met and maintained to protect those
uses (i.e. water quality objectives).
Project construction activities would include grading, excavation, installation of subsurface
infrastructure, and other earthmoving activities which could potentially cause erosion that could
degrade surface or ground water quality and/or violate water quality standards. Moreover, the
use of heavy construction equipment could result in the accidental release of hazardous
materials (e.g., oils, fuels, and other water quality pollutants) that could potentially affect surface
and/or ground water quality. As required by the Clean Water Act, the project would comply with
the Santa Ana Municipal Separate Storm Sewer (MS4) NPDES Permit. The NPDES MS4
Jack in the Box El Toro Class 32 Categorical Exemption Checklist -
Page 14 of 18
Permit Program, which is administered in the project area by Riverside County and is issued by
the SARWQCB, regulates storm water and urban runoff discharges from developments to
natural and constructed storm drain systems in the City. Because the project would disturb one
or more acres of soil, construction activities would be subject to the Construction General Permit
(NPDES General Permit No. CAS000002, Waste Discharge Requirements, Order No. 2009-
0009-DWQ, adopted September 2, 2009 and effective as of July 2, 2010) issued by the State
Water Resources Control Board. The Construction General Permit requires implementation of a
Storm Water Pollution Prevention Plan (SWPPP) for site clearing, grading, and disturbances
such as stockpiling or excavation. The SWPPP would generally contain a site map showing the
construction perimeter, proposed buildings, storm water collection and discharge points, general
pre- and post-construction topography, drainage patterns across the site, and adjacent
roadways.
The project area is currently undeveloped and contains approximately 5,086 square feet of
impervious surfaces. Existing onsite drainage flows toward the Frontage Road right-of-way, then
flow southward and eventually to Temescal Creek. The proposed development includes
construction of two restaurant drive-through buildings with parking lots, driveway, landscaping
with a total impervious surface area of approximately 79,655 square feet.
Conclusion: A project-specific Preliminary Water Quality Management Plan dated January 14,
2022 (Revised June 21, 2022) has been prepared to address the increase in polluted runoff that
would occur from the project by describing the site design, source control and treatment control
Best Management Practices (BMPs) that will be implemented and maintained throughout the life
of the project. The water quality management plan proposes to collect and treat onsite
stormwater run-off through multiple bioretention basins and a modular wetland system. The
onsite drainage from roofs and pavement areas will be collected by the treatment facilities
where stormwater would percolate through an engineered soil medium in which stormwater
would be treated by physical, chemical, and biological processes. The plants and biological
activity in the soil medium would function to take up pollutants and runoff, thus filtering the water
before it is released into the municipal storm drain system. Furthermore, the project is required
to implement a Storm Water Pollution Prevention Plan which will include measures such as
construction-phase best management practices (BMPs) to protect against stormwater runoff.
Through implementation of measures specified in both the WQMP and SWPPP, along with
adhering to applicable regulations, the project would meet applicable water quality standards
and discharge regulations. Therefore, the project would not otherwise substantially degrade
surface or ground water quality, and any water quality impacts resulting from the project would
be less than significant.
For additional information, refer to the Preliminary Water Quality Management Plan included as
Appendix E to this report.
Criterion (e): Can the project site be adequately served by all required utilities and public
services?
Fire Protection: The project would be subject to City policies and ordinances relating to hazard
mitigation and fire prevention. The project would be required to comply with applicable fire code
Jack in the Box El Toro Class 32 Categorical Exemption Checklist -
Page 15 of 18
requirements for construction and access to the site which will be reviewed by the City Fire
Department to determine the project-specific fire requirements. Chapter 16.74 of the LEMC
establishes a program for the adoption and administration of development impact fees by the
City whereby as a condition to the issuance of a building permit or certificate of occupancy by
the City, the property owner or land developer is required to pay development impact fees or
provide other consideration to the City for the purpose of defraying the costs of public
expenditures for capital improvements (and operational services to the extent allowed by law)
which will benefit such new development. Section 16.74.049 includes a “fire facilities fee” to
mitigate the additional burdens created by new development for City fire facilities. The project
would incrementally increase demands for fire protection services associated with service calls,
inspections, etc. The increase in demand for fire protection services is not anticipated to require
the construction of new facilities or infrastructure. Therefore, any impacts related to fire
protection resulting from the project would be less than significant.
Police Protection: Chapter 16.74 of the LEMC establishes a program for the adoption and
administration of development impact fees by the City for the purpose of defraying the costs of
public expenditures for capital improvements (and operational services to the extent allowed by
law) which would benefit such new development. The project would participate in this
development impact fee program to mitigate potential impacts to police protection resources.
Additionally, the project would be required to comply with applicable law enforcement
requirements and standards to ensure adequate law enforcement protection is available to
serve the proposed development. Potential impacts would be considered incremental and can
be offset through the payment of the development impact fee and compliance with regulatory
requirements. The project would not result in substantial adverse physical impacts related to
police protection. Therefore, the project would not significantly impact police protection
resources or services.
Schools: The proposed development is located within the Lake Elsinore Unified School District
(LEUSD). The project would be required to pay school impact fees as levied by the LEUSD,
which would provide funding for school facilities. The project does not propose new housing and
therefore no increase in demand for LEUSD facilities and services would be created. Therefore,
any potential impacts would be considered incremental and would be offset through the
payment of the appropriate development impact fees for schools. Based on the above, the
proposed project will not result in substantial adverse physical impacts related to schools. Any
impacts would be less than significant.
Parks: The project does not propose residential uses so it would not generate additional
residents who would need park facilities or services. Therefore, a direct increase in park usage
is not expected because of the project. New commercial development may cause incremental
indirect impacts to park facilities from the occasional use of a park by employees. Section
16.34.060 of the LEMC requires that prior to the issuance of a building permit, the property
owner or developer must pay fees for the purposes set forth in that section. Section 16.34.060.D
describes the City’s Park Capital Improvement Fund and describes that the City Council has the
option to request dedication for park purposes or in lieu thereof, request that the property owner
or developer pay a fee for the purpose of purchasing the land and developing and maintaining
Jack in the Box El Toro Class 32 Categorical Exemption Checklist -
Page 16 of 18
the City park system. The project would be required to pay park fees to the City for the purpose
of establishing, improving, and maintaining park land within the City. Because the project does
not propose new housing, any potential impacts would be considered incremental and would be
offset through the payment of the appropriate park fees. Based on the above, the project would
not result in substantial adverse physical impacts related to parks. Any impacts would be less
than significant.
Other Public Facilities: The City is a part of the Riverside County Library System. Section
16.34.060 of the LEMC requires that prior to the issuance of a building permit, the property
owner or developer must pay fees for the purposes set forth in that section. Section 16.34.060.B
establishes the City’s Library Mitigation Fee program and provides that an in-lieu fee for future
construction of library improvements shall be paid to the City to ensure that the necessary
library facilities are provided to the community. Since the project would not include new housing,
potential impacts to library services would be less than significant.
Chapter 16.74 of the LEMC establishes a program for the adoption and administration of
development impact fees by the City for the purpose of defraying the costs of public
expenditures for capital improvements (and operational services to the extent allowed by law)
which would benefit such new development. Section 16.74.048 includes an “Animal shelter
facilities fee” to mitigate the additional burdens created by new development for animal facilities.
In addition, the property owner would be required to pay City Hall & Public Works fees,
Community Center Fees, and Marina Facilities Fees prior to the issuance of building permits.
Therefore, potential impacts associated with other public services and facilities would be less
than significant.
Wastewater/Sewer: The proposed development is located within the wastewater/sewer service
boundary of the Elsinore Valley Municipal Water District (EVMWD). The proposed development
would connect with the EVMWD wastewater/sewer system. Connections to local sewer mains
will involve temporary and less than significant construction impacts that will occur in
conjunction with other on-site improvements. In addition, the project will be required to pay
sewer connection fees. Implementation of the project will not require, or result in, the
construction of new wastewater treatment facilities or expansion of existing facilities, the
construction of which could cause significant environmental effects. Any impacts would be less
than significant.
Storm Water Drainage: On-site grading and drainage improvements proposed in conjunction
with the proposed site work would be required to comply with provisions of the National
Pollutant Discharge Elimination System (NPDES) program, including Waste Discharge
Requirements (WDR), and the 2010 Santa Ana Municipal Separate Sewer Permit (MS4) Permit,
as enforced by the Santa Ana Regional Water Quality Board (SARWQCB). Pursuant to the
City’s Municipal Code, all construction projects shall implement Best Management Practices
(BMPs) to be specified in a submitted Stormwater Pollution Prevention Plan (SWPPP). The
project was required to submit a project-specific Water Quality Management Plan (WQMP) in
identifying post-construction BMPs that include drainage controls such as infiltration pits,
detention ponds, bioswales, berms, rain gardens, and pervious pavement. Upon adherence to
Jack in the Box El Toro Class 32 Categorical Exemption Checklist -
Page 17 of 18
the approved WQMP, the project will not substantially alter the existing drainage pattern of the
site or area, nor will it require new or expanded off-site storm drain facilities the construction or
relocation of which could cause significant environmental effects. Any impacts would be less
than significant.
Water Supplies: The proposed development is located within the water service boundary of the
Elsinore Valley Municipal Water District (EVMWD). The proposed development would connect
to the EVMWD water supply system. Connections to local water mains will involve temporary
and less than significant construction impacts that will occur in conjunction with other on-site
improvements. In addition, the project will be required to pay water connection fees and comply
with water efficiency guidelines set by the City. Project implementation will not require, or result
in, the construction of new water treatment facilities or expansion of existing facilities, the
construction of which would cause significant environmental effects. Given the relatively small
scale of the proposed in-fill development, potential impacts are considered nominally
incremental and would be less than significant.
Solid Waste Disposal: All development within the City of Lake Elsinore is required to comply
with applicable elements of AB 1327, Chapter 18 (California Solid Waste Reuse and Recycling
Access Act of 1991), AB 939 (CalRecycle), and other local, state, and federal solid waste
disposal standards. The California Integrated Waste Management Act of 1989 (AB 939)
requires every city and county in the state to prepare a Source Reduction and Recycling
Element (SRRE) to its Solid Waste Management Plan, that identifies how each jurisdiction will
meet the mandatory state diversion goal of 50% by and after the year 2000. The purpose of AB
939 is to “reduce, recycle, and re-use solid waste generated in the state to the maximum extent
feasible.” The project is required to comply with applicable elements of AB 1327, Chapter 18
(California Solid Waste Reuse and Recycling Access Act of 1991), AB 939, and other applicable
local, state, and federal solid waste disposal standards as a matter of regulatory policy as
standard condition of approval, thereby ensuring that the solid waste stream to the waste
disposal facilities is reduced in accordance with existing regulations. Any impacts would be less
than significant.
Electricity, Natural Gas, Telephone, Television: The proposed development is in a
developed, urban setting. The site and the surrounding properties are fully served by various
utility service providers. There are no anticipated significant service or system upgrades
required to serve the proposed development. Any increase in the demand for public utilities by
the project would be less than significant.
DETERMINATION:
I find that the answers given above are adequately supported by the information sources cited
following each question and that the effects of the project are typical of those generated within
that class of projects (i.e., Class 32 – Infill Development Projects) characterized as in-fill
development meeting the conditions of Section 15332 of Title 14 of the California Code of
Regulations. The project will not cause a significant effect on the environment and is therefore
categorically exempt from the requirement for the preparation of environmental documents under
the California Environmental Quality Act.
Jack in the Box El Toro Class 32 Categorical Exemption Checklist -
Page 18 of 18
Kevin Beery 02/16/2023
Kevin Beery, Associate Planner Date
Appendices:
The following documents were used as information sources during preparation of this
document. They are available for public review at the City of Lake Elsinore, Community
Development Department, 130 South Main Street, Lake Elsinore, CA 92530, ph. (951) 674-
3124.
A) Western Riverside County – MSHCP Consistency Analysis Highway 74 – El Toro Cut
Off Drive Thru Restaurant Final Report (Biological Report) dated May 2022 prepared by
Cadre Environmental
B) Vehicle Miles Traveled (VMT) Evaluation prepared by Trames Solutions Inc. dated
January 18, 2023
C) Noise Assessment prepared by Ldn Consulting, Inc. dated August 31, 2022
D) Air Quality Assessment prepared by Ldn Consulting, Inc. dated August 31, 2022
E) Preliminary Water Quality Management Plan prepared by Commercial Development
Resources dated January 14, 2022 (Revised June 21, 2022)
RESOLUTION NO. 2023-__
A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF LAKE
ELSINORE, CALIFORNIA, ADOPTING FINDINGS THAT PLANNING
APPLICATION NO. 2021-25 (CONDITIONAL USE PERMIT NO. 2022-01,
CONDITIONAL USE PERMIT NO. 2022-04 AND COMMERCIAL DESIGN REVIEW
NO. 2022-01) IS CONSISTENT WITH THE WESTERN RIVERSIDE COUNTY
MULTIPLE SPECIES HABITAT CONSERVATION PLAN
Whereas, Gabriela Marks, Marks Architects, has filed an application with the City of Lake
Elsinore (City) requesting approval of Planning Application No. 2021-25 (Conditional Use Permit
No. 2022-01, Conditional Use Permit No. 2022-04, and Commercial Design Review No. 2022-01)
to construct and operate two drive-through restaurants (2,646 sq. ft. and 624 sq. ft., respectively)
on adjacent parcels in the Ramsgate Specific Plan. The project site is located on the northwest
side of Highway 74, southeast of North Frontage Road and bisected by El Toro Cut Off Road in
the Ramsgate Specific Plan. (APNs: 347-130-033; 347-130-034; 347-130-035); and,
Whereas, Section 6.0 of the Multiple Species Habitat Conservation Plan (MSHCP)
requires that all discretionary projects within a MSHCP Criteria Cell undergo the Lake Elsinore
Acquisition Process (LEAP) and the Joint Project Review (JPR) to analyze the scope of the
proposed development and establish a building envelope that is consistent with the MSHCP
criteria; and,
Whereas, Section 6.0 of the MSHCP further requires that the City adopt consistency
findings demonstrating that the proposed discretionary entitlement complies with the MSHCP
Criteria Cell, and the MSHCP goals and objectives; and,
Whereas, pursuant to Section 17.415.070.B of the LEMC, the Planning Commission
(Commission) has the responsibility of reviewing and approving, conditionally approving, or
denying conditional use permit applications,
Whereas, pursuant to Section 17.415.050 (Major Design Review) of the Lake Elsinore
Municipal Code (LEMC), the Planning Commission (Commission) has the responsibility of
reviewing and approving, conditionally approving, or denying design review applications; and,
Whereas, on February 21, 2023, at a duly noticed Public Hearing the Commission has
considered evidence presented by the Community Development Department and other interested
parties with respect to this item.
NOW THEREFORE, THE PLANNING COMMISSION OF THE CITY OF LAKE
ELSINORE DOES HEREBY RESOLVE, DETERMINE AND ORDER AS FOLLOWS:
Section 1: The Commission has considered the project and its consistency with the
MSHCP prior to adopting Findings of Consistency with the MSHCP.
Section 2: That in accordance with the MSHCP, the Commission makes the following
findings for MSHCP consistency:
PC Reso. No. 2023-____
Page 2 of 6
2
6
3
6
9
1. The Project is a project under the City’s MSHCP Resolution, and the City must
make an MSHCP Consistency finding before approval.
Approximately 2.42 acres of the project site is located within an MSHCP criteria
cell. Pursuant to the City’s MSHCP Resolution, the project has been reviewed for
MSHCP consistency, including consistency with “Other Plan Requirements.”
These include the Protection of Species Associated with Riparian/Riverine Areas
and Vernal Pool Guidelines (MSHCP, § 6.1.2), Protection of Narrow Endemic Plant
Species Guidelines (MSHCP, § 6.1.3), Additional Survey Needs and Procedures
(MSHCP, § 6.3.2), Urban/Wildlands Interface Guidelines (MSHCP, § 6.1.4),
Vegetation Mapping (MSHCP, § 6.3.1) requirements, Fuels Management
Guidelines (MSHCP, § 6.4), and payment of the MSHCP Local Development
Mitigation Fee (MSHCP Ordinance, § 4).
2. The Project is subject to the City’s LEAP and the Western Riverside County
Regional Conservation Authority’s (RCA) Joint Project Review processes.
Approximately 2.42 acres of the project site is located in the southern portion of
Criteria Cell 4076 within Cell Group X, which is in MSHCP Elsinore Area Plan,
Subunit 3 (Elsinore). Therefore, a formal and complete LEAP application, LEAP
2022-02 was submitted to the City on January 12, 2022.
3. The Project is consistent with the Riparian/Riverine Areas and Vernal Pools
Guidelines.
On October 20, 2021, Cadre Environmental conducted a field survey of the site to
determine whether the project site includes riparian/riverine area or vernal pools in
accordance with the RCIP definition (Section 6.1.2, Volume I, Final MSHCP). The
assessment included a review of historic aerials and soils maps within and
immediately adjacent to the Project Site. No vegetation communities representing
MSHCP Section 6.1.2 riparian scrub, forest or woodland resources were
documented within or adjacent to the Project Site.
Vernal pools are depressions in areas where a hard-underground layer prevents
rainwater from draining downward into the subsoils. When rain fills the pools in the
winter and spring, the water collects and remains in the depressions. In the
springtime, the water gradually evaporates away, until the pools became
completely dry in the summer and fall. Vernal pools tend to have an impermeable
layer that results in ponded water. The soil texture (the amount of sand, silt, and
clay particles) typically contains higher amounts of fine silts and clays with lower
percolation rates. Pools that retain water for a sufficient length of time will develop
hydric cells. Hydric cells form when the soil is saturated from flooding for extended
periods of time and anaerobic conditions (lacking oxygen or air) develop.
No evidence of vernal pool, ephemeral depressions, stock ponds, road ruts or
other wetland features were recorded on the Project Site.
PC Reso. No. 2023-____
Page 3 of 6
2
6
3
6
9
The Project Site is characterized as Arbuckle gravelly loam, Cieneba rocky sandy
loam, Vallecitos loam, Vista coarse sandy loam, and Ysidora gravelly very fine
sandy loam possessing well drained substrates (drainage class). No indication of
clay substrates or hydric soils were documented within the Project Site.
A review of historic aerials was conducted to determine if inundated features were
present during years of high rainfall when features would certainly be documented.
Historic aerials taken in 2011 represent an ideal baseline during which know
(previously documented) inundated vernal pool, ephemeral depressions, stock
ponds, road ruts can easily be seen. No sign of indication of inundation was
documented within the Project Site during a review of historic aerials.
In summary, none of the conditions (i.e., no inundated depressions including road
ruts, hydric soils, historic inundation, etc.) were observed on documented within
the Project Site. No features are present that would support fairy shrimp. No
standing water or other sign of areas that pond water was recorded.
The Project is therefore consistent with the Riparian/Riverine Areas and Vernal
Pool Guidelines set forth in Section 6.1.2 of the MSHCP. No further action
regarding this section of the MSHCP is required.
4. The Project is consistent with the Protection of Narrow Endemic Plant Species
Guidelines.
The property is not in a Narrow Endemic Plant Species Survey Area (NEPSSA)
for any narrow endemic species, and no NEPSSA surveys are required.
The proposed project is therefore consistent with the Protection of Narrow
Endemic Plant Species Guidelines.
5. The Project is consistent with the Additional Survey Needs and Procedures.
The MSHCP requires additional surveys for certain species if the project is located
in certain locations. Pursuant to MSHCP Figure 6-2 (Criteria Area Species Survey
Area), Figure 6-3 (Amphibian Species Survey Areas with Criteria Area), Figure 6-
4 (Burrowing Owl Survey Areas with Criteria Area), Figure 6-5 (Mammal Species
Survey Areas With Criteria Area), burrowing owl surveys are required for the
subject property prior to approval of a development proposal.
The property is not located within survey areas for criteria area species (MSHCP
Figure 6-2), amphibian species (MSHCP Figure 6-3), or mammal species (MSHCP
Figure 6-5) and surveys for those species are not required.
A burrowing owl (Athene cunicularia) habitat assessment was conducted by Cadre
Environmental during its October 20, 2021 field survey of the project site. Prior to
initiating the assessment survey, Cadre Environmental used binoculars to scan all
suitable habitats on and adjacent to the Project Site, including perch locations, to
ascertain owl presence. All suitable areas of the Project Site were surveyed on
foot by walking slowly and methodically while recording/mapping areas that may
represent suitable owl habitat onsite. Concurrent with the initial habitat
PC Reso. No. 2023-____
Page 4 of 6
2
6
3
6
9
assessment, a detailed focused burrow survey was conducted and included
documentation of appropriately sized natural burrows or suitable man-made
structures that may be utilized by burrowing owl as part of the MSHCP protocol.
No potential burrowing owl burrows (a total of three borrows were documented <
3 inches in diameter) or characteristic sign such as white-wash, feathers, tracks,
or pellets were detected within the Project Site. (See Figure 3, Burrowing Owl
Survey Area.) The Project Site is not currently occupied by burrowing owl.
Regardless, suitable habitat is located adjacent and north of the property and the
species could potentially be indirectly impacted as a result of project initiation.
Nevertheless, as a mitigation measure for the proposed project, the City of Lake
Elsinore will require a pre-construction presence/absence survey for burrowing owl
to be conducted within 30 days of the commencement of project-related grading
or other land disturbance activities including vegetation clearing, clearing and
grubbing, tree removal, or site water, to ensure that the species has not moved
onto the site since completion of the surveys. If burrowing owl have colonized the
property site prior to the initiation of construction, the Project proponent shall
immediately inform the Wildlife Agencies and the RCA, and prepare a Burrowing
Owl Protection and Relocation Plan for approval by RCA and the Wildlife Agencies,
prior to initiating ground disturbance. Additionally, if ground-disturbing activities
occur, but the site is left undisturbed for more than 30 days, a pre-construction
survey will again be necessary to ensure burrowing owl have not colonized the site
since it was last disturbed. If burrowing owl are found, the same coordination
described above will be necessary.
Therefore, the subject project is consistent with the Additional Survey Needs and
Procedures of the MSHCP.
6. The Project is consistent with the Urban/Wildlands Interface Guidelines.
Section 6.1.4 of the MSHCP sets forth guidelines that are intended to address
indirect effects associated with locating development in proximity to the MSHCP
Conservation Area, where applicable.
The guidelines in Section 6.1.4 of the MSHCP are intended to address indirect
effects associated with development near MSHCP Conserved Areas.
Developments in proximity to MSHCP Conserved Areas may result in “edge
effects” that might adversely affect biological resources within MSHCP Conserved
Areas. Lake Elsinore, which is identified as “Public/Quasi Public (PQP) Conserved
Lands” by the MSHCP is located to the north and west of the project site.
According to the MSHCP development may occur adjacent to Conservation Areas.
Future Development in proximity to Conservation Areas may result in Edge Effects
that will adversely affect biological resources within the Conservation Areas. To
minimize such Edge Effects, the Project Applicant will be required to follow the
Urban/Wildlands Interface Guidelines in Section 6.1.4 of the MSHCP to minimize
urban/wildlands interface issues in the nearby Criteria Area. These include
measures related to indirect impacts such as water quality (drainage), use of
toxics, night lighting, indirect noise, invasive plant and wildlife species, protection
PC Reso. No. 2023-____
Page 5 of 6
2
6
3
6
9
of habitat areas (barriers), and grading/land development adjacent to habitat
areas.
The 3.76-acre Project Site impact area is not located adjacent to an existing or
proposed MSHCP Conservation Area. Regardless, all applicable proposed
Urban/Wildlands Interface guidelines will be implemented for the proposed Project
Site impact area. Compliance with all the following MSHCP Urban/Wildlands
Interface guidelines will ensure that the proposed project will not result in
significant indirect impacts to potential future proposed conservation areas in the
northern region of Cell Group X.
7. The Project is consistent with the Vegetation Mapping requirements.
On October 20, 2021, Cadre Environmental conducted a field survey of the site.
The field survey identified plant and animal species found on the project site. The
Project site contains 3.26 acres of disturbed/developed land and 0.50 acres of
Riversidean Sage Scrub, as shown on Figure 4.
This mapping is sufficient under the MSHCP and is consistent with the MSHCP
vegetation mapping requirements.
8. The proposed project is consistent with the Fuels Management Guidelines.
Section 6.4 of the MSHCP requires that new developments adjacent to the
MSHCP Conservation Area or other undeveloped lands incorporate any fuel/brush
management zones and Best Management Practices. The 3.76-acre Project Site
impact area is not located adjacent to an existing or proposed MSHCP
Conservation Area, is proposed as a non-combustible commercial development,
and undeveloped areas adjacent to the Project Site are anticipated to be
developed and is therefore not expected to be subject to fuel modification
requirements
Therefore, the Project is consistent with the Fuels Management Guidelines as set
forth in Section 6.4 of the MSHCP.
9. The Project will be conditioned to pay the City’s MSHCP Local Development
Mitigation Fee.
The project has been conditioned to pay the City’s MSHCP Local Development
Mitigation Fee prior to issuance of building permits for the project.
10. The Project is consistent with the MSHCP.
Based on the reasons above, the project is consistent with the MSHCP.
Section 3: Based upon the evidence presented, both written and testimonial, and the
above findings, the Commission hereby finds that the project is consistent with the MSHCP.
Section 4: This Resolution shall take effect immediately upon its adoption.
PC Reso. No. 2023-____
Page 6 of 6
2
6
3
6
9
Passed and Adopted on this 21st day of February, 2023.
Matthew Dobler, Chairman
Attest:
___________________________________
Damaris Abraham,
Interim Assistant Community Development Director
STATE OF CALIFORNIA )
COUNTY OF RIVERSIDE ) ss.
CITY OF LAKE ELSINORE )
I, Damaris Abraham, Interim Assistant Community Development Director of the City of Lake
Elsinore, California, hereby certify that Resolution No. 2023-__ was adopted by the Planning
Commission of the City of Lake Elsinore, California, at a regular meeting held February 21, 2023
and that the same was adopted by the following vote:
AYES:
NOES:
ABSTAIN:
ABSENT:
Damaris Abraham,
Interim Assistant Community Development Director
RESOLUTION NO. 2023-
A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF LAKE
ELSINORE, CALIFORNIA, APPROVING CONDITIONAL USE PERMIT NO. 2022-01
TO ESTABLISH A 2,649 SQUARE-FOOT DRIVE-THROUGH RESTAURANT AT
APNS: 347-130-033 AND 347-130-034
Whereas, Gabriela Marks, Marks Architects, has filed an application with the City of Lake
Elsinore (City) requesting approval of Planning Application No. 2021-25 (Conditional Use Permit
No. 2022-01, Conditional Use Permit No. 2022-04, and Commercial Design Review No. 2022-01)
to construct and operate two drive-through restaurants (2,646 sq. ft. and 624 sq. ft., respectively)
on adjacent parcels in the Ramsgate Specific Plan. The project site is located on the northwest
side of Highway 74, southeast of North Frontage Road and bisected by El Toro Cut Off Road in
the Ramsgate Specific Plan. (APNs: 347-130-033; 347-130-034; 347-130-035); and,
Whereas, Section 17.415.070.A of the Lake Elsinore Municipal Code (LEMC) provides
that certain uses have operational characteristics that, depending on the location and design of
the use, may have the potential to negatively impact adjoining properties, businesses or residents
and therefore are permitted subject to the issuance of a Conditional Use Permit, which allows the
City to comprehensively review and approve the use; and,
Whereas, pursuant to Section 17.415.070.B of the LEMC, the Planning Commission
(Commission) has the responsibility of reviewing and approving, conditionally approving, or
denying Conditional Use Permits; and,
Whereas, on February 21, 2023, at a duly noticed Public Hearing, the Commission has
considered evidence presented by the Community Development Department and other interested
parties with respect to this item.
NOW, THEREFORE, THE PLANNING COMMISSION OF THE CITY OF LAKE
ELSINORE, CALIFORNIA, DOES HEREBY RESOLVE, DETERMINE AND ORDER AS
FOLLOWS:
Section 1: The Commission has considered the project and has found it acceptable.
Section 2: The Commission finds that the proposed project is exempt from the California
Environmental Quality Act (Cal. Pub. Res. Code §§21000 et seq.: “CEQA”) and the CEQA
Guidelines (14 C.C.R. §§ 15000 et seq.) pursuant to CEQA Guidelines Section 15332 In-fill
Development Projects because the project (a) is consistent with the applicable general plan
designation and all applicable general plan policies as well as with applicable zoning designation
and regulations, (b) the site of the proposed development is within city limits on a project site of
less than five acres substantially surrounded by urban uses, (c) the project site has no value as
habitat for endangered, rare or threatened species, (d) the project will not result in any significant
effects relating to traffic, noise, air quality, or water quality, and (e) the site can be adequately
served by all required utilities and public services.
Section 3: That in accordance with LEMC Section 17.415.070.C. Findings, the
Commission makes the following findings regarding Conditional Use Permit No. 2022-01:
1. That the proposed use is in accord with the objectives of the General Plan and the purpose
of the planning district in which the site is located.
PC Reso. No. 2023-____
Page 2 of 3
2
6
3
7
0
The project site is located in the Ramsgate Specific Plan and has a land use designation
of Commercial. This designation is primarily intended to accommodate a shopping area
that provides convenience goods and services for the residential neighborhoods.
According to Section 9.2 of the Ramsgate Specific Plan, fast food restaurants including
drive-throughs are permitted subject to approval of a use permit. Furthermore, the
proposed development conforms to the applicable development standards and criteria of
the Commercial designation. Therefore, the proposed drive-through food establishment is
consistent with the commercial designation of the subject site as described in the
Ramsgate Specific Plan.
2. The proposed use will not be detrimental to the general health, safety, comfort or general
welfare of persons residing or working within the neighborhood of the proposed use or the
City, or injurious to property or improvements in the neighborhood or the City.
The proposed use does not involve the potential for causing detrimental effects to the
existing surrounding community or the general public. The proposed drive-through
restaurants are compatible with the surrounding uses in the vicinity. The project has been
conditioned as such to avoid any possible negative impacts associated with the proposed
project.
3. The site is adequate in size and shape to accommodate the use, and for all the yards,
setbacks, walls or fences, landscaping, buffers and other features required by this title.
The proposed site plan provides sufficient drive-through lane lengths to accommodate
assumed peak vehicle queuing space, as well as provide conforming building and drive
lane setbacks from the right-of-way.
4. The site for the proposed use relates to streets and highways with proper design both as
to width and type of pavement to carry the type and quantity of traffic generated by the
subject use.
The project would include construction of frontage improvements, construction of a new
traffic signal at the Highway 74 and El Toro Cut Off Road, and payment of a 1.5 percent
fair share contribution to a new traffic signal at Highway 74 and Crater Drive. Furthermore,
the project has been designed to ensure that drive-through operations do not impact
surrounding roadways due to queuing spillover. Therefore, the proposed improvements
will be sufficient for the type and quantity of traffic generated by the proposed use.
5. In approving the subject use at the specific location, there will be no adverse effect on
abutting properties or the permitted and normal use thereof.
The project has been thoroughly reviewed and conditioned by all applicable City
departments thereby eliminating the potential for any adverse effects.
6. Adequate conditions and safeguards pursuant to LEMC 17.415.070.B, including
guarantees and evidence of compliance with conditions, have been incorporated into the
approval of the subject project to ensure development of the property in accordance with
the objectives of this chapter and the planning district in which the site is located.
Pursuant to Section 17.415.070.B of the LEMC, the project was considered by the
Planning Commission at a duly noticed Public Hearing on February 21, 2023, appropriate
PC Reso. No. 2023-____
Page 3 of 3
2
6
3
7
0
and applicable conditions of approval have been included to protect the public health,
safety and general welfare.
Section 4: Based upon the evidence presented, the above findings, and the Conditions
of Approval imposed upon the project, the Commission hereby approves Conditional Use Permit
No. 2022-01.
Section 5: This Resolution shall take effect immediately upon its adoption.
Passed and Adopted on this 21st of February, 2023.
Matthew Dobler, Chairman
Attest:
___________________________________
Damaris Abraham,
Interim Assistant Community Development Director
STATE OF CALIFORNIA )
COUNTY OF RIVERSIDE ) ss.
CITY OF LAKE ELSINORE )
I, Damaris Abraham, Interim Assistant Community Development Director of the City of Lake
Elsinore, California, hereby certify that Resolution No. 2023-__ was adopted by the Planning
Commission of the City of Lake Elsinore, California, at a regular meeting held February 21, 2023
and that the same was adopted by the following vote:
AYES:
NOES:
ABSTAIN:
ABSENT:
Damaris Abraham,
Interim Assistant Community Development Director
RESOLUTION NO. 2023-
A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF LAKE
ELSINORE, CALIFORNIA, APPROVING CONDITIONAL USE PERMIT NO. 2022-04
TO ESTABLISH A 624 SQUARE-FOOT DRIVE-THROUGH RESTAURANT AT APN:
347-130-035
Whereas, Gabriela Marks, Marks Architects, has filed an application with the City of Lake
Elsinore (City) requesting approval of Planning Application No. 2021-25 (Conditional Use Permit
No. 2022-01, Conditional Use Permit No. 2022-04, and Commercial Design Review No. 2022-01)
to construct and operate two drive-through restaurants (2,646 sq. ft. and 624 sq. ft., respectively)
on adjacent parcels in the Ramsgate Specific Plan. The project site is located on the northwest
side of Highway 74, southeast of North Frontage Road and bisected by El Toro Cut Off Road in
the Ramsgate Specific Plan. (APNs: 347-130-033; 347-130-034; 347-130-035); and,
Whereas, Section 17.415.070.A of the Lake Elsinore Municipal Code (LEMC) provides
that certain uses have operational characteristics that, depending on the location and design of
the use, may have the potential to negatively impact adjoining properties, businesses or residents
and therefore are permitted subject to the issuance of a Conditional Use Permit, which allows the
City to comprehensively review and approve the use; and,
Whereas, pursuant to Section 17.415.070.B of the LEMC, the Planning Commission
(Commission) has the responsibility of reviewing and approving, conditionally approving, or
denying Conditional Use Permits; and,
Whereas, on February 21, 2023, at a duly noticed Public Hearing, the Commission has
considered evidence presented by the Community Development Department and other interested
parties with respect to this item.
NOW, THEREFORE, THE PLANNING COMMISSION OF THE CITY OF LAKE
ELSINORE, CALIFORNIA, DOES HEREBY RESOLVE, DETERMINE AND ORDER AS
FOLLOWS:
Section 1: The Commission has considered the project and has found it acceptable.
Section 2: The Commission finds that the proposed project is exempt from the California
Environmental Quality Act (Cal. Pub. Res. Code §§21000 et seq.: “CEQA”) and the CEQA
Guidelines (14 C.C.R. §§ 15000 et seq.) pursuant to CEQA Guidelines Section 15332 In-fill
Development Projects because the project (a) is consistent with the applicable general plan
designation and all applicable general plan policies as well as with applicable zoning designation
and regulations, (b) the site of the proposed development is within city limits on a project site of
less than five acres substantially surrounded by urban uses, (c) the project site has no value as
habitat for endangered, rare or threatened species, (d) the project will not result in any significant
effects relating to traffic, noise, air quality, or water quality, and (e) the site can be adequately
served by all required utilities and public services.
Section 3: That in accordance with LEMC Section 17.415.070.C. Findings, the
Commission makes the following findings regarding Conditional Use Permit No. 2022-04:
1. That the proposed use is in accord with the objectives of the General Plan and the purpose
of the planning district in which the site is located.
PC Reso. No. 2023-____
Page 2 of 3
2
6
3
7
1
The project site is located in the Ramsgate Specific Plan and has a land use designation
of Commercial. This designation is primarily intended to accommodate a shopping area
that provides convenience goods and services for the residential neighborhoods.
According to Section 9.2 of the Ramsgate Specific Plan, fast food restaurants including
drive-throughs are permitted subject to approval of a use permit. Furthermore, the
proposed development conforms to the applicable development standards and criteria of
the Commercial designation. Therefore, the proposed drive-through food establishment is
consistent with the commercial designation of the subject site as described in the
Ramsgate Specific Plan.
2. The proposed use will not be detrimental to the general health, safety, comfort or general
welfare of persons residing or working within the neighborhood of the proposed use or the
City, or injurious to property or improvements in the neighborhood or the City.
The proposed use does not involve the potential for causing detrimental effects to the
existing surrounding community or the general public. The proposed drive-through
restaurants are compatible with the surrounding uses in the vicinity. The project has been
conditioned as such to avoid any possible negative impacts associated with the proposed
project.
3. The site is adequate in size and shape to accommodate the use, and for all the yards,
setbacks, walls or fences, landscaping, buffers and other features required by this title.
The proposed site plan provides sufficient drive-through lane lengths to accommodate
assumed peak vehicle queuing space, as well as provide conforming building and drive
lane setbacks from the right-of-way.
4. The site for the proposed use relates to streets and highways with proper design both as
to width and type of pavement to carry the type and quantity of traffic generated by the
subject use.
The project would include construction of frontage improvements, construction of a new
traffic signal at the Highway 74 and El Toro Cut Off Road, and payment of a 1.5 percent
fair share contribution to a new traffic signal at Highway 74 and Crater Drive. Furthermore,
the project has been designed to ensure that drive-through operations do not impact
surrounding roadways due to queuing spillover. Therefore, the proposed improvements
will be sufficient for the type and quantity of traffic generated by the proposed use.
5. In approving the subject use at the specific location, there will be no adverse effect on
abutting properties or the permitted and normal use thereof.
The project has been thoroughly reviewed and conditioned by all applicable City
departments thereby eliminating the potential for any adverse effects.
6. Adequate conditions and safeguards pursuant to LEMC 17.415.070.B, including
guarantees and evidence of compliance with conditions, have been incorporated into the
approval of the subject project to ensure development of the property in accordance with
the objectives of this chapter and the planning district in which the site is located.
Pursuant to Section 17.415.070.B of the LEMC, the project was considered by the
Planning Commission at a duly noticed Public Hearing on February 21, 2023, appropriate
PC Reso. No. 2023-____
Page 3 of 3
2
6
3
7
1
and applicable conditions of approval have been included to protect the public health,
safety and general welfare.
Section 4: Based upon the evidence presented, the above findings, and the Conditions
of Approval imposed upon the project, the Commission hereby approves Conditional Use Permit
No. 2022-04.
Section 5: This Resolution shall take effect immediately upon its adoption.
Passed and Adopted on this 21st day of February, 2023.
Matthew Dobler, Chairman
Attest:
___________________________________
Damaris Abraham,
Interim Assistant Community Development Director
STATE OF CALIFORNIA )
COUNTY OF RIVERSIDE ) ss.
CITY OF LAKE ELSINORE )
I, Damaris Abraham, Interim Assistant Community Development Director of the City of Lake
Elsinore, California, hereby certify that Resolution No. 2023-__ was adopted by the Planning
Commission of the City of Lake Elsinore, California, at a regular meeting held February 21, 2023
and that the same was adopted by the following vote:
AYES:
NOES:
ABSTAIN:
ABSENT:
Damaris Abraham,
Interim Assistant Community Development Director
RESOLUTION NO. 2023-
A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF LAKE
ELSINORE, CALIFORNIA, APPROVING COMMERCIAL DESIGN REVIEW NO.
2022-01 PROVIDING BUILDING DESIGN AND RELATED IMPROVEMENTS FOR
TWO DRIVE-THROUGH RESTAURANTS TO BE LOCATED AT APNS: 347-130-
033, 347-130-034 and 347-130-035
Whereas, Gabriela Marks, Marks Architects, has filed an application with the City of Lake
Elsinore (City) requesting approval of Planning Application No. 2021-25 (Conditional Use Permit
No. 2022-01, Conditional Use Permit No. 2022-04, and Commercial Design Review No. 2022-01)
to construct and operate two drive-through restaurants (2,646 sq. ft. and 624 sq. ft., respectively)
on adjacent parcels in the Ramsgate Specific Plan. The project site is located on the northwest
side of Highway 74, southeast of North Frontage Road and bisected by El Toro Cut Off Road in
the Ramsgate Specific Plan. (APNs: 347-130-033; 347-130-034; 347-130-035); and
Whereas, pursuant to Section 17.415.050 (Major Design Review) of the Lake Elsinore
Municipal Code (LEMC), the Planning Commission (Commission) has the responsibility of
reviewing and approving, conditionally approving, or denying design review applications; and,
Whereas, on February 21, 2023, at a duly noticed Public Hearing, the Commission has
considered evidence presented by the Community Development Department and other interested
parties with respect to this item.
NOW, THEREFORE, THE PLANNING COMMISSION OF THE CITY OF LAKE
ELSINORE DOES HEREBY RESOLVE, DETERMINE AND ORDER AS FOLLOWS:
Section 1: The Commission has reviewed and analyzed the proposed project pursuant to
the California Planning and Zoning Laws (Cal. Gov. Code §§ 59000 et seq.), the Lake Elsinore
General Plan (GP), and the LEMC and finds and determines that the proposed project is
consistent with the requirements of California Planning and Zoning Law and with the goals and
policies of the GP, the Ramsgate Specific Plan and the LEMC.
Section 2: The Commission finds that the proposed project is exempt from the California
Environmental Quality Act (Cal. Pub. Res. Code §§21000 et seq.: “CEQA”) and the CEQA
Guidelines (14 C.C.R. §§ 15000 et seq.) pursuant to CEQA Guidelines Section 15332 In-fill
Development Projects because the project (a) is consistent with the applicable general plan
designation and all applicable general plan policies as well as with applicable zoning designation
and regulations, (b) the site of the proposed development is within city limits on a project site of
less than five acres substantially surrounded by urban uses, (c) the project site has no value as
habitat for endangered, rare or threatened species, (d) the project will not result in any significant
effects relating to traffic, noise, air quality, or water quality, and (e) the site can be adequately
served by all required utilities and public services.
Section 3: That in accordance with Section 17.415.050.G of the LEMC, the Commission
makes the following findings regarding Commercial Design Review No. 2022-01:
1. The project, as approved, will comply with the goals and objectives of the General Plan
and the zoning district in which the project is located.
PC Reso. No. 2023-____
Page 2 of 3
2
6
3
7
2
The project site is located in the Ramsgate Specific Plan and has a land use designation
of Commercial. This designation is primarily intended to accommodate a shopping area
that provides convenience goods and services for the residential neighborhoods. Pursuant
to Section 9.2 of the Ramsgate Specific Plan, fast food restaurants including drive-
throughs are permitted subject to approval of a use permit.
Therefore, the proposed drive-through fast food establishments are consistent with the
commercial designation of the subject site as described in the General Plan. The proposed
commercial project will assist in achieving the development of a well-balanced and
functional mix of residential, commercial, industrial, open space, recreational and
institutional land uses.
2. The Project complies with the design directives contained in the LEMC and all applicable
provisions of the LEMC.
The project is appropriate to the site and surrounding developments. The architectural
design of the proposed buildings conforms to the Nonresidential Development Standards
(Chapter 17.112) of the LEMC. Sufficient setbacks and enhanced onsite landscaping have
been provided thereby creating interest and varying vistas as a person moves along
abutting streets. The architecture has been designed to achieve harmony and
compatibility with the surrounding area. The colors and materials proposed will assist in
blending the architecture into the existing landscape and are compatible with other colors
and materials used on other properties near the project site. In addition, safe and efficient
circulation has been achieved onsite.
3. Conditions and safeguards pursuant to Section 17.415.050.G.3 of the LEMC, including
guarantees and evidence of compliance with conditions, have been incorporated into the
approval of the Project to ensure development of the property in accordance with the
objectives of Section 17.415.050.
Pursuant to Section 17.415.050.E of the LEMC, the project was considered by the
Planning Commission at a duly noticed Public Hearing held on February 21, 2023. The
project, as reviewed and conditioned by all applicable City divisions, departments and
agencies, will not have a significant effect on the environment.
Section 4: Based upon the evidence presented, the above findings, and the Conditions
of Approval imposed upon the project, the Commission hereby approves Commercial Design
Review No. 2022-01.
Section 5: This Resolution shall take effect immediately upon its adoption.
Passed and Adopted on this 21st day of February, 2023.
Matthew Dobler, Chairman
PC Reso. No. 2023-____
Page 3 of 3
2
6
3
7
2
Attest:
___________________________________
Damaris Abraham,
Interim Assistant Community Development Director
STATE OF CALIFORNIA )
COUNTY OF RIVERSIDE ) ss.
CITY OF LAKE ELSINORE )
I, Damaris Abraham, Interim Assistant Community Development Director of the City of Lake
Elsinore, California, hereby certify that Resolution No. 2023-__ was adopted by the Planning
Commission of the City of Lake Elsinore, California, at a regular meeting held February 21, 2023
and that the same was adopted by the following vote:
AYES:
NOES:
ABSTAIN:
ABSENT:
Damaris Abraham,
Interim Assistant Community Development Director
Applicant’s Initials: _____ Page 1 of 20
CONDITIONS OF APPROVAL
PROJECT: PA 2021-25/CUP 2022-01/CUP 2022-
04/CDR 2022-01
PROJECT NAME:Jack in the Box El Toro
PROJECT LOCATION:APNs: 347-130-033, 347-130-034 and
347-130-035
APPROVAL DATE:
EFFECTIVE DATE:
EXPIRATION DATE:
GENERAL
1.Planning Application No. 2021-39 (Conditional Use Permit No. 2021-15 and Commercial
Design Review No. 2021-19) proposes to construct and operate two drive-through
restaurants on adjacent parcels in the Ramsgate Specific Plan. The project site is located
on the northwest side of Highway 74, southeast of North Frontage Road and bisected by El
Toro Cut Off Road in the Ramsgate Specific Plan. (APNs: 347-130-033; 347-130-034; 347-
130-035)
2.The applicant shall defend (with counsel acceptable to the City), indemnify, and hold
harmless the City, its Officials, Officers, Employees, Agents, and its Consultants
(Indemnitees) from any claim, action, or proceeding against the Indemnitees to attack, set
aside, void, or annul an approval of the City, its advisory agencies, appeal boards, or
legislative body concerning approval, implementation and construction of CUP 2022-01,
CUP 2022-04 and CDR 2022-01, which action is bought within the time period provided for
in California Government Code Sections 65009 and/or 66499.37, and Public Resources
Code Section 21167, including the approval, extension or modification of CUP 2022-01,
CUP 2022-04 and CDR 2022-01 or any of the proceedings, acts or determinations taken,
done, or made prior to the decision, or to determine the reasonableness, legality or validity
of any condition attached thereto. The Applicant's indemnification is intended to include, but
not be limited to, damages, fees and/or costs awarded against or incurred by Indemnitees
and costs of suit, claim or litigation, including without limitation attorneys' fees, penalties and
other costs, liabilities and expenses incurred by Indemnitees in connection with such
proceeding. The City will promptly notify the applicant of any such claim, action, or
proceeding against the City. If the project is challenged in court, the City and the applicant
shall enter into formal defense and indemnity agreement, consistent with this condition.
3.Within 30 days of project approval, the applicant shall sign and complete an
"Acknowledgment of Conditions" and shall return the executed original to the Community
Development Department for inclusion in the case records.
PLANNING DIVISION
4.Conditional Use Permit No. 2022-01 shall lapse and become void two years following the
date on which the conditional use permit became effective, unless one of the following: (1)
prior to the expiration of two years, a building permit related to the conditional use permit is
issued and construction commenced and diligently pursued toward completion; or (2) prior
to the expiration of two years, the applicant has applied for and has been granted an
extension of the conditional use permit approval pursuant to subsections (a), (b), and (c) of
Lake Elsinore Municipal Code (LEMC) Section 17.415.070.D.2. Subject to the provisions of
PA 2021-25/CUP 2022-01/CUP 2022-04/CDR 2022-01 PC:
Conditions of Approval CC:
Applicant’s Initials: _____Page 2 of 20
LEMC Section 17.415.070.I, a conditional use permit granted pursuant to the provisions of
this section shall run with the land and shall continue to be valid upon a change of ownership
of the site or structure, which was the subject of the Conditional Use Permit application.
5.Conditional Use Permit No. 2022-04 shall lapse and become void two years following the
date on which the conditional use permit became effective, unless one of the following: (1)
prior to the expiration of two years, a building permit related to the conditional use permit is
issued and construction commenced and diligently pursued toward completion; or (2) prior
to the expiration of two years, the applicant has applied for and has been granted an
extension of the conditional use permit approval pursuant to subsections (a), (b), and (c) of
Lake Elsinore Municipal Code (LEMC) Section 17.415.070.D.2. Subject to the provisions of
LEMC Section 17.415.070.I, a conditional use permit granted pursuant to the provisions of
this section shall run with the land and shall continue to be valid upon a change of ownership
of the site or structure, which was the subject of the Conditional Use Permit application.
6.Commercial Design Review No. 2022-01 shall lapse and become void two years following
the date on which the design review became effective, unless one of the following: (1) prior
to the expiration of two years, a building permit related to the design review is issued and
construction commenced and diligently pursued toward completion; or (2) prior to the
expiration of two years, the applicant has applied for and has been granted an extension of
the design review approval pursuant to subsections (1) and (2) of Lake Elsinore Municipal
Code (LEMC) Section 17.415.050.I.1. Notwithstanding conditions to the contrary, a design
review granted pursuant to LEMC Section 17.415.050.I.2 shall run with the land for this two-
year period, subject to any approved extensions, and shall continue to be valid upon a
change of ownership of the site, which was the subject of the design review application.
7.An application for modification, expansion or other change in a Conditional Use Permit shall
be reviewed according to the provisions of the Section 17.415.070 of the LEMC, in a similar
manner as a new application.
8.If operation of this use raises concerns related to parking, noise, traffic, or other impacts, at
the discretion of the Community Development Director, this Conditional Use Permit may be
referred back to the Planning Commission for subsequent review at a Public Hearing. If
necessary, the Commission may modify or add conditions of approval to mitigate such
impacts, or may revoke said Conditional Use Permit.
9.All Conditions of Approval shall be reproduced on page one of building plans prior to their
acceptance by the Building and Safety Division, Community Development Department. All
Conditions of Approval shall be met prior to the issuance of a Certificate of Occupancy and
release of utilities.
10.All future development proposals shall be reviewed by the City on a project-by-project basis.
If determined necessary by the Community Development Director or designee, additional
environmental analysis will be required.
11.Any proposed minor revisions to approved plans shall be reviewed and approved by the
Community Development Director or designee. Any proposed substantial revisions to the
approved plans shall be reviewed according to the provisions of the Municipal Code in a
similar manner as a new application. Grading plan revisions shall be reviewed by the City
Engineer.
PA 2021-25/CUP 2022-01/CUP 2022-04/CDR 2022-01 PC:
Conditions of Approval CC:
Applicant’s Initials: _____Page 3 of 20
12.Provisions of the City's Noise Ordinance (LEMC Chapter 17.176) shall be satisfied during
all site preparation and construction activity. Site preparation activity and construction shall
not commence before 7:00 AM and shall cease no later than 5:00 PM, Monday through
Friday. Only finish work and similar interior construction may be conducted on Saturdays
and may commence no earlier than 8:00 am and shall cease no later than 4:00 p.m.
Construction activity shall not take place on Sunday, or any Legal Holidays.
13.The following noise prevention measures shall be implemented during project construction:
i. During construction, the contactor shall ensure all construction equipment is
equipped with appropriate noise attenuating devices.
ii. The contractor should locate equipment staging areas that will create the greatest
distance between construction-related noise/vibration sources and sensitive
receptors nearest the project site during all project construction.
iii. Idling equipment should be turned off when not in use.
14.No individual signs are approved as part of this approval. The applicant or designee shall
submit an application for a sign permit, pay appropriate fees and receive approval from the
Community Development Department for any sign(s) installed at the project site.
15.Graffiti shall be removed within 24 hours.
16.All materials and colors depicted on the approved plans shall be used. If the applicant
wishes to modify any of the approved materials or colors depicted on the plans, the applicant
shall submit a proposal setting forth the modifications for review by the Community
Development Director or his designee
17.The entire site shall be kept free from trash and debris at all times and in no event shall
trash and debris remain for more than 24 hours.
18.The measures identified in the submitted Queueing Management Plan shall be implemented
to ensure that operation of the drive-throughs do not interfere with free and orderly
circulation of the parking lots and to avoid spillover of vehicles into public right-of-way.
19.If any of the conditions of approval set forth herein fail to occur, or if they are, by their terms,
to be implemented and maintained over time, if any of such conditions fail to be so
implemented and maintained according to their terms, the City shall have the right to revoke
or modify all approvals herein granted, deny or further condition issuance of all future
building permits, deny revoke, or further condition all certificates of occupancy issued under
the authority of approvals herein granted; record a notice of violation on the property title;
institute and prosecute litigation to compel their compliance with said conditions or seek
damages for their violation
Prior to Issuance of Grading Permits/Building Permits
20.Prior to issuance of a building permit, the applicant shall pay Development Impact Fees
(DIF) and Multiple Species Habitat Conservation Plan (MSHCP) Fees per LEMC Section
16.85, at the rate in effect at the time of payment.
21.All roof mounted or ground support air conditioning units or other mechanical equipment
incidental to development shall be architecturally screened or shielded by landscaping so
that they are not visible from neighboring property or public streets. Any roof mounted
PA 2021-25/CUP 2022-01/CUP 2022-04/CDR 2022-01 PC:
Conditions of Approval CC:
Applicant’s Initials: _____Page 4 of 20
central swamp coolers shall also be screened, and the Community Development Director,
prior to issuance of building permit shall approve screening plan.
22.The project shall meet all requirements of the Elsinore Valley Municipal Water District
(EVMWD). The applicant shall submit water and sewer plans to the EVMWD and shall
incorporate all district conditions and standards.
23.The property address (in numerals at least six inches high) shall be displayed near the
entrance and be easily visible from the front of the subject property and public right-of-way.
24.The applicant shall construct trash enclosure(s) with a decorative roof to match the colors,
materials and design of the project architecture.
25.Prior to issuance of a building permit, the Final Landscaping / Irrigation Detail Plans shall
be submitted to the Community Development Department with appropriate fees, for review
and approval by the Community Development Director or designee.
a. All planting areas shall have permanent and automatic sprinkler system with 50% plant
coverage using a drip irrigation method.
b. All planting areas shall be separated from paved areas with a six inch (6”) high and six
inch (6”) wide concrete curb. Runoff shall be allowed from paved areas into landscape
areas.
c. Planting within fifteen feet (15’) of ingress/egress points shall be no higher than twenty-
four inches (24”).
d. Landscape planters shall be planted with an appropriate parking lot shade tree
pursuant to the LEMC and Landscape Design Guidelines.
e. No required tree planting bed shall be less than 5 feet wide.
f. Root barriers shall be installed for all trees planted within 10 feet of hardscape areas
to include sidewalks.
g. Any transformers and mechanical or electrical equipment shall be indicated on
landscape plan and screened as part of the landscaping plan.
h. The landscape plan shall provide for ground cover, shrubs, and trees and meet all
requirements of the City’s adopted Landscape Guidelines.
i. All landscaping and irrigation shall be installed within affected portion of any phase at
the time a Certificate of Occupancy is requested for any building.
j. Final landscape plan must be consistent with approved site plan.
k. Final landscape plans to include planting and irrigation details and shall blend in with
the existing shopping center.
l. Final landscape plans shall include drought tolerant planting consistent with Elsinore
Valley Municipal Water District standards subject to plan check and approval by the
City’s landscape plan check consultant.
m. No turf shall be permitted.
26.Landscaping installed for the project shall be continuously maintained to the reasonable
satisfaction of the Community Development Director. If it is determined that the landscaping
is not being maintained, the Director of Community Development shall have the authority to
require the property owner to bring the landscaping into conformance with the approved
landscape plan. The continued maintenance of all landscaped areas shall be the
responsibility of the developer or any successors in interest.
27.The proposed location of on-site construction trailers shall be approved by the Community
PA 2021-25/CUP 2022-01/CUP 2022-04/CDR 2022-01 PC:
Conditions of Approval CC:
Applicant’s Initials: _____Page 5 of 20
Development Director or designee. A cash bond of $1,000 shall be required for any
construction trailers placed on the site and used during construction. Bonds will be released
after removal of trailers and restoration of the site to an acceptable state, subject to approval
of the Community Development Director or designee. Such trailer(s) shall be fully on private
property and outside the public right of way.
Multiple Species Habitat Conservation Plan (MSHCP) Measures
28.Due to the presence of potentially suitable habitat, a 30-day preconstruction survey for
burrowing owls is required prior to initial ground-disturbing activities (including vegetation
clearing, clearing and grubbing, tree removal, site watering, equipment staging, grading,
etc.) to ensure that no owls have colonized the site in the days or weeks preceding the
ground-disturbing activities. If burrowing owls have colonized the project site prior to the
initiation of ground-disturbing activities, the project proponent will immediately inform the
Regional Conservation Authority (RCA) and the Wildlife Agencies, and will need to
coordinate further with RCA and the Wildlife Agencies, including the possibility of preparing
a Burrowing Owl Protection and Relocation Plan, prior to initiating ground disturbance. If
ground-disturbing activities occur, but the site is left undisturbed for more than 30 days, a
pre-construction survey will again be necessary to ensure burrowing owl has not colonized
the site since it was last disturbed. If burrowing owl is found, the same coordination
described above will be necessary.
29.Pursuant to Section 6.1.4 of the MSHCP, applicant shall implement the following measures
as applicable:
i. Incorporate measures to control the quantity and quality of runoff from the site
entering the MSHCP Conservation Area. In particular, measures shall be put in
place to avoid discharge of untreated surface runoff from developed and paved
areas into MSHCP Conservation Areas. Best Management Practices (BMPs) will
be implemented to prevent the release of toxins, chemicals, petroleum products,
exotic plant materials, or other elements that might degrade or harm downstream
biological resources or ecosystems.
ii. Land uses proposed in proximity to the MSHCP Conservation Area that use
chemicals or generate bioproducts, such as manure, that are potentially toxic or
may adversely affect wildlife species, Habitat, or water quality shall incorporate
measures to ensure that application of such chemicals does not result in
discharge to the MSHCP Conservation Area. The greatest risk is from
landscaping fertilization overspray and runoff.
iii. Night lighting shall be directed away from the MSHCP Conservation Area and
the avoided area on site to protect species from direct night lighting.
iv. Proposed noise-generating land uses affecting the MSHCP Conservation Area,
including designated avoidance areas, shall incorporate setbacks, berms, or
walls to minimize the effects of noise on MSHCP Conservation Area resources
pursuant to applicable rules, regulations, and guidelines related to land use
noise standards.
v. Avoid use of invasive, non-native plant species listed in Table 6-2 of the MSHCP
in approving landscape plans for the portions of the project that are adjacent to
the MSHCP Conservation Area, including avoidance areas. Considerations in
reviewing the applicability of this list shall include proximity of planting areas to
the MSHCP Conservation Areas and designated avoidance areas, species
considered in the planting plans, resources being protected within the MSHCP
PA 2021-25/CUP 2022-01/CUP 2022-04/CDR 2022-01 PC:
Conditions of Approval CC:
Applicant’s Initials: _____Page 6 of 20
Conservation Area and their relative sensitivity to invasion, and barriers to plant
and seed dispersal, such as walls, topography, and other features.
vi. Proposed land uses adjacent to the MSHCP Conservation Area shall
incorporate barriers, where appropriate, in individual project designs to minimize
unauthorized public access, domestic animal predation, illegal trespass, or
dumping into existing and future MSHCP Conservation Areas. Such barriers
may include native landscaping, rocks/boulders, fencing, walls, signage, and/or
other appropriate mechanisms.
vii. Manufactured slopes associated with proposed site development shall not
extend into the MSHCP Conservation Area.
viii. Weed abatement and fuel modification activities are not permitted in the
Conservation Area, including designated avoidance areas.
30.Pursuant to Appendix C of the MSHCP, the following best management practices (BMPs),
as applicable, shall be implemented for the duration of construction:
i. A condition shall be placed on grading permits requiring a qualified biologist to
conduct a training session for project personnel prior to grading. The training shall
include a description of the species of concern and its habitats, the general
provisions of the Endangered Species Act (Act) and the MSHCP, the need to
adhere to the provisions of the Act and the MSHCP, the penalties associated with
violating the provisions of the Act, the general measures that are being
implemented to conserve the species of concern as they relate to the project, and
the access routes to and project site boundaries within which the project activities
must be accomplished.
ii. Water pollution and erosion control plans shall be developed and implemented in
accordance with RWQCB requirements.
iii. The footprint of disturbance shall be minimized to the maximum extent feasible.
Access to sites shall be via pre-existing access routes to the greatest extent
possible.
iv. The upstream and downstream limits of projects disturbance plus lateral limits of
disturbance on either side of the stream shall be clearly defined and marked in the
field and reviewed by the biologist prior to initiation of work.
v. Projects should be designed to avoid the placement of equipment and personnel
within the stream channel or on sand and gravel bars, banks, and adjacent upland
habitats used by target species of concern.
vi. Projects that cannot be conducted without placing equipment or personnel in
sensitive habitats should be timed to avoid the breeding season of riparian species
identified in MSHCP Global Species Objective No. 7.
vii. When stream flows must be diverted, the diversions shall be conducted using
sandbags or other methods requiring minimal instream impacts. Silt fencing of
other sediment trapping materials shall be installed at the downstream end of
construction activity to minimize the transport of sediments off site. Settling ponds
where sediment is collected shall be cleaned out in a manner that prevents the
sediment from reentering the stream. Care shall be exercised when removing silt
fences, as feasible, to prevent debris or sediment from returning to the stream.
viii. Equipment storage, fueling, and staging areas shall be located on upland sites with
minimal risks of direct drainage into riparian areas or other sensitive habitats.
PA 2021-25/CUP 2022-01/CUP 2022-04/CDR 2022-01 PC:
Conditions of Approval CC:
Applicant’s Initials: _____Page 7 of 20
These designated areas shall be located in such a manner as to prevent any runoff
from entering sensitive habitat. Necessary precautions shall be taken to prevent
the release of cement or other toxic substances into surface waters. Project related
spills of hazardous materials shall be reported to appropriate entities including but
not limited to applicable jurisdictional city, FWS, and CDFG, RWQCB and shall be
cleaned up immediately and contaminated soils removed to approved disposal
areas.
ix. Erodible fill material shall not be deposited into water courses. Brush, loose soils,
or other similar debris material shall not be stockpiled within the stream channel or
on its banks.
x. The qualified project biologist shall monitor construction activities for the duration
of the project to ensure that practicable measures are being employed to avoid
incidental disturbance of habitat and species of concern outside the project
footprint.
xi. The removal of native vegetation shall be avoided and minimized to the maximum
extent practicable. Temporary impacts shall be returned to pre-existing contours
and revegetated with appropriate native species.
xii. Exotic species that prey upon or displace target species of concern should be
permanently removed from the site to the extent feasible.
xiii. To avoid attracting predators of the species of concern, the project site shall be
kept as clean of debris as possible. All food related trash items shall be enclosed
in sealed containers and regularly removed from the site(s).
xiv. Construction employees shall strictly limit their activities, vehicles, equipment, and
construction materials to the proposed project footprint and designated staging
areas and routes of travel. The construction area(s) shall be the minimal area
necessary to complete the project and shall be specified in the construction plans.
Construction limits will be fenced with orange snow screen. Exclusion fencing
should be maintained until the completion of all construction activities. Employees
shall be instructed that their activities are restricted to the construction areas.
xv. The Permittee shall have the right to access and inspect any sites of approved
projects including any restoration/enhancement area for compliance with project
approval conditions, including these BMPs.
BUILDING DIVISION
General Conditions
1.Final Building and Safety Conditions. Final Building and Safety Conditions will be addressed
when building construction plans are submitted to Building and Safety for review. These
conditions will be based on occupancy, use, the California Building Code (CBC), and related
codes which are enforced at the time of building plan submittal.
2.Compliance with Code. All design components shall comply with applicable provisions of
the 2022 edition of the California Building, Plumbing and Mechanical Codes: 2022 California
Electrical Code; California Administrative Code, 2022 California Energy Codes, 2022
California Green Building Standards, California Title 24 Disabled Access Regulations, and
Lake Elsinore Municipal Code.
3.Green Measures. The application shall provide 10% voluntary green measures on the
PA 2021-25/CUP 2022-01/CUP 2022-04/CDR 2022-01 PC:
Conditions of Approval CC:
Applicant’s Initials: _____Page 8 of 20
project, as stipulated by the 2022 California Green Building Standards.
4.Disabled Access. Applicant shall provide details of all applicable disabled access provisions
and building setbacks on plans to include:
a. All ground floor units to be adaptable.
b. Disabled access from the public way to the entrance of the building.
c. Van accessible parking located as close as possible to the main entry.
d. Path of accessibility from parking to furthest point of improvement.
e. Path of travel from public right-of-way to all public areas on site, such as club house,
trach enclosure tot lots and picnic areas.
5.Street Addressing. Applicant must obtain street addressing for all proposed buildings by
requesting street addressing and submitting a site plan for commercial or multi-family
residential projects or a recorded final map for single- family residential projects. It takes 10
days to issue address and notify other agencies. Please contact Sonia Salazar at
ssalazar@lake-elsinore.org or 951-674-3124 X 277.
6.Clearance from LEUSD. A receipt or clearance letter from the Lake Elsinore School District
shall be submitted to the Building and Safety Department to ensure the payment or
exemption from School Mitigation Fees.
7.Obtain Approvals Prior to Construction. Applicant must obtain all building plans and permit
approvals prior to commencement of any construction work.
8.Obtaining Separate Approvals and Permits. Trash enclosures, patio covers, light standards,
and any block walls will require separate approvals and permits.
9.Sewer and Water Plan Approvals. On-site sewer and water plans will require separate
approvals and permits. Septic systems will need to be approved from Riverside County
Environmental Health Department before permit issuance.
10.House Electrical Meter. Applicant shall provide a house electrical meter to provide power
for the operation of exterior lighting, irrigation pedestals and fire alarm systems for each
building on the site. Developments with single user buildings shall clearly show on the plans
how the operation of exterior lighting and fire alarm systems when a house meter is not
specifically proposed.
At Plan Review Submittal
11.Submitting Plans and Calculations. Applicant must submit to Building and Safety four (4)
complete sets of plans and two (2) sets of supporting calculations for review and approval
including:
a. An electrical plan including load calculations and panel schedule, plumbing schematic,
and mechanical plan applicable to scope of work.
b. A Sound Transmission Control Study in accordance with the provisions of the Section
5.507, of the 202241 edition of the California Building Code.
c. A precise grading plan to verify accessibility for the persons with disabilities.
d. Truss calculations that have been stamped by the engineer of record of the building and
the truss manufacturer engineer.
PA 2021-25/CUP 2022-01/CUP 2022-04/CDR 2022-01 PC:
Conditions of Approval CC:
Applicant’s Initials: _____Page 9 of 20
Prior to Issuance of Grading Permit(s)
12.Onsite Water and Sewer Plans. Onsite water and sewer plans, submitted separately from
the building plans, shall be submitted to Building and Safety for review and approval.
13.Demolition Permits. A demolition permit shall be obtained if there is an existing structure to
be removed as part of the project. Asbestos report and lead base paint reports are required
before demo permit will be issued.
Prior to Issuance of Building Permit(s)
14.Plans Require Stamp of Registered Professional. Applicant shall provide appropriate stamp
of a registered professional with original signature on the plans. Provide C.D. of approved
plans to the Building Division.
Prior to Beginning of Construction
15.Pre-Construction Meeting. A pre-construction meeting is required with the building inspector
prior to the start of the building construction.
ENGINEERING DEPARTMENT
GENERAL
16.All new submittals for plan check or permit shall be made using the City’s online Citizen
Self-Service Portal (CSSP).
17.All plans (Street, Storm Drain, Improvement, Grading) shall be prepared by a Registered
Civil Engineer using the City’s standard title block.
18.All required soils, geology, hydrology and hydraulic and seismic reports shall be prepared
by a Registered Civil Engineer.
19.All slopes and landscaping within the public right-of-way shall be maintained by the property
owner, owner’s association, firms contracted by the property owner’s association, or another
maintenance entity approved by the City Council.
20.All open space and slopes except for public parks and schools and flood control district
facilities, outside the public right-of-way shall be owned and maintained by the property
owner or property owner’s association.
21.In accordance with the City’s Franchise Agreement for waste disposal & recycling, the
applicant shall be required to contract with CR&R Inc. for removal and disposal of all waste
material, debris, vegetation and other rubbish generated both during cleaning, demolition,
clear and grubbing or all other phases of construction and during occupancy.
22.Applicant shall submit a detailed hydrology and hydraulic study for review for the sufficient
containment and conveyance of the storm water to a safe and adequate point as approved
by the City Engineer.
PA 2021-25/CUP 2022-01/CUP 2022-04/CDR 2022-01 PC:
Conditions of Approval CC:
Applicant’s Initials: _____Page 10 of 20
23.The site will accommodate all construction activity, building activity, vehicles, etc. No staging
on public streets, or private property belonging to others shall be conducted without the
written permission of the property owner.
24.Minimum good housekeeping and erosion and sediment control Best Management
Practices (BMPs) as identified by the City shall be implemented.
FEES
25.Applicant shall pay all applicable permit application and Engineering Department assessed
fees, including without limitation plan check and construction inspection fees, at the
prevalent rate at time of payment in full.
26.Applicant shall pay all applicable Mitigation and Development Impact Fees at the prevalent
rate at time of payment in full. Mitigation and Development Impact Fees include without
limitation:
•Master Plan of Drainage Fee – Due prior to Grading Permit issuance
•Traffic Infrastructure Fee (TIF) – Due prior to Building Permit issuance
•Transportation Uniform Mitigation Fee (TUMF) – Due prior to Occupancy
•Stephens’ Kangaroo Habitat Fee (K-Rat) – Due prior to Grading Permit issuance
LAND DIVISION-DEDICATION
27.Applicant shall dedicate right-of-way along Central Avenue (State Route 74) adjacent to
the property frontage for a minimum total right-of-way of 67 feet from centerline to the
project property line. Central Avenue is classified as an Augmented Urban Arterial
Highway in the City’s General Plan Circulation Element, where full-width is 134 feet and
curb-to-curb width is 110 feet.
28.Applicant shall submit plan check review and approval for right of way vacation at the
northerly terminus of N. Frontage Road resulting in a 30 feet street half section. N. Frontage
Road is classified as a Local Street with a 60-foot right of way.
29.Underground water rights shall be dedicated to the City pursuant to the provisions of Section
16.52.030 in the Lake Elsinore Municipal Code (LEMC), and consistent with the City’s
agreement with the Elsinore Valley Municipal Water District.
30.Covenants, Conditions and Restrictions (CC&Rs) shall be submitted to the City for review
approval.
31.Applicant shall submit a parcel merger application for plan check and approval for APN’s
347-130-033 and 347-130-034. The parcel merger shall be recorded prior to building permit
issuance.
STORM WATER MANAGEMENT / POLLUTION PREVENTION / NPDES
Design
32.The project is responsible for complying with the Santa Ana Region National Pollutant
Discharge Elimination System (NPDES) Permits as warranted based on the nature of
PA 2021-25/CUP 2022-01/CUP 2022-04/CDR 2022-01 PC:
Conditions of Approval CC:
Applicant’s Initials: _____Page 11 of 20
development and/or activity.
33.The 2010 SAR MS4 Permit requires evaluation of the site for implementation of LID
Principles and LID Site Design, where feasible, to treat the pollutants of concern identified
for the project (Section XXII.E.2, XII.E3, and XII.E.7).
34.A Final Water Quality Management Plan (WQMP) shall be prepared using the Santa Ana
Region of Riverside County Guidance Document and approved template and submitted for
review and approval to the City.
•The Final WQMP shall be approved by the City prior to rough grading plan approval,
or issuance of any permit for construction, whichever is first.
35.The Final WQMP shall document the following:
•Detailed site and project description.
•Potential stormwater pollutants.
•Post-development drainage characteristics.
•Low Impact Development (LID) BMP selection and analysis.
•Structural and non-structural source control BMPs.
•Treatment Control BMPs.
•Site design and drainage plan (BMP Exhibit).
•Documentation of how vector issues are addressed in the BMP design, operation and
maintenance.
•GIS Decimal Minute Longitude and Latitude coordinates for all LID and Treatment
Control BMP locations.
•Hydraulic Conditions of Concern (HCOC) – demonstrate that discharge flow rates,
velocities, duration and volume for the post construction condition from a 2-year, 24-
hour rainfall event will not cause adverse impacts on downstream erosion and
receiving waters, or measures are implemented to mitigate significant adverse
impacts downstream public facilities and water bodies. Evaluation documentation
shall include pre- and post-development hydrograph volumes, time of concentration
and peak discharge velocities, construction of sediment budgets, and a sediment
transport analysis. If HCOC applies, the project shall implement measures to limit
disturbance of natural water bodies and drainage systems; conserve natural areas;
protect slopes and channels; and minimize significant impacts from urban runoff.
(Note the facilities may need to be larger due to flood mitigation for the 10-year, 6-
and 24-hour rain events).
•Operations and Maintenance (O&M) Plan and Agreement (using City approved form
and/or CC&Rs) as well as documentation of formation of funding district for long term
maintenance costs.
36.Parking lot landscaping areas shall be designed to provide for treatment, retention or
infiltration of runoff.
37.Project hardscape areas shall be designed and constructed to provide for drainage into
adjacent landscape.
38.Project trash enclosure shall be covered, bermed, and designed to divert drainage from
adjoining paved areas and regularly maintained.
39.If CEQA identifies resources requiring Clean Water Act Section 401 Permitting, the applicant
PA 2021-25/CUP 2022-01/CUP 2022-04/CDR 2022-01 PC:
Conditions of Approval CC:
Applicant’s Initials: _____Page 12 of 20
shall obtain certification through the Santa Ana Regional Water Quality Control Board and
provide a copy to the Engineering Department.
40.All storm drain inlet facilities shall be appropriately marked “Only Rain in the Storm Drain”
using the City authorized marker.
41.The project shall use either volume-based and/or flow-based criteria for sizing BMPs in
accordance with NPDES Permit Provision XII.D.4.
42.The project site shall implement full trash capture methods/devices approved by the Region
Water Quality Control Board. This shall include installation of connector pipe screens on all
onsite catch basins and all offsite catch basins to which the project discharges.
43.All restaurants and commercial food handling facilities must provide an area for the
washing/steam cleaning of equipment and accessories. The area must be self-contained,
equipped with a grease trap, and properly connected to a sanitary sewer. If the wash area
is located outdoors, it must be covered, paved have secondary containment, and be
connected to the sanitary sewer or other appropriately permitted disposal facility. Plan
Requirements: The Owner/Applicant shall incorporate these food facility requirements into
project design and depict on plans, including detail plans as needed.
Construction
44.A Storm Water Pollution Prevention Plan (SWPPP) (as required by the NPDES General
Construction Permit) and compliance with the Green Building Code for sediment and
erosion control are required for this project.
45.Prior to grading or building permit for construction or demolition and/or weed abatement
activity, projects subject to coverage under the NPDES General Construction Permit shall
demonstrate that compliance with the permit has been obtained by providing a copy of the
Notice of Intent (NOI) submitted to the State Water Resources Control Board and a copy
of the notification of the issuance of a Waste Discharge Identification (WDID) Number or
other proof of filing to the satisfaction of the City Engineer. A copy of the SWPPP shall be
kept at the project site, updated, and be available for review upon request.
46.Erosion & Sediment Control – Prior to the issuance of any grading or building permit for
construction or demolition, the applicant shall submit for review and approval by the City
Engineer, an Erosion and Sediment Control Plan as a separate sheet of the grading plan
submittal to demonstrate compliance with the City’s NPDES Program and state water
quality regulations for grading and construction activities. A copy of the plan shall be
incorporated into the SWPPP, kept updated as needed to address changing
circumstances of the project site, be kept at the project site, and available for review upon
request.
Post-Construction
47.Prior to the issuance of a certificate of use and/or occupancy, the applicant shall
demonstrate compliance with applicable NPDES permits for construction,
industrial/commercial, MS4, etc. to include:
•Demonstrate that the project has compiled with all non-structural BMPs described in
the project’s WQMP.
PA 2021-25/CUP 2022-01/CUP 2022-04/CDR 2022-01 PC:
Conditions of Approval CC:
Applicant’s Initials: _____Page 13 of 20
•Provide signed, notarized certification from the Engineer of Work that the structural
BMPs identified in the project’s WQMP are installed in conformance with approved
plans and specifications and operational.
•Submit a copy of the fully executed, recorded City approved Operations and
Maintenance (O&M) Plan and Agreement for all structural BMPs or a copy of the
recorded City approved CC&R.
•The O&M Plan and Agreement and/or CC&R’s shall: (1) describe the long-term
operation and maintenance requirements for BMPs identified in the BMP Exhibit; (2)
identify the entity that will be responsible for long-term operation and maintenance of
the referenced BMPs; (3) describe the mechanism for funding the long-term operation
and maintenance of the referenced BMPs; and (4) provide for annual certification for
water quality facilities by a Registered Civil Engineer. The City format shall be used.
•Provide documentation of annexation into a CFD for funding facilities to be maintained
by the City.
•Demonstrate that copies of the project’s approved WQMP (with recorded O&M Plan
or CC&R’s attached) are available for each of the initial occupants.
•Agree to pay for a Special Investigation from the City of Lake Elsinore for a date twelve
(12) months after the issuance of a Certificate of Use and/or Occupancy for the project
to verify compliance with the approved WQMP and O&M Plan. A signed/sealed
certification from the Engineer of Work dated 12 months after the Certificate of
Occupancy will be considered in lieu of a Special Investigation by the City.
•Provide the City with a digital .pdf copy of the Final WQMP.
UTILITIES
48.All arrangements for relocation of utility company facilities (power poles, vaults, etc.) out of
the roadway shall be the responsibility of the applicant, property owner, and/or his agent.
Overhead utilities (34.5 kV or lower) shall be undergrounded (LEMC Section 16.64).
49.Underground water rights shall be dedicated to the City pursuant to the provisions of
LEMC Section 16.52.030, and consistent with the City’s agreement with the Elsinore
Valley Municipal Water District.
50.Applicant shall apply for, obtain and submit to the City Engineering Department a letter from
Southern California Edison (SCE) indicating that the construction activity will not interfere
with existing SCE facilities. Non-Interference Letter (NIL) shall be provided prior to issuance
of Grading Permit.
51.Submit a “Will Serve” letter to the City Engineering Department from the applicable water
agency stating that water and sewer arrangements have been made for this project and
specify the technical data for the water service at the location, such as water pressure,
volume, etc. Will Serve letters shall be provided prior to issuance of Grading Permit.
IMPROVEMENTS
52.Applicant shall implement traffic mitigation measures identified in the Traffic Impact
Analysis by Trames Solutions Inc. dated August 1, 2022, as specified in Section 6.0 of the
study.
53.All street improvements shall be implemented as part of the first phase of the project.
PA 2021-25/CUP 2022-01/CUP 2022-04/CDR 2022-01 PC:
Conditions of Approval CC:
Applicant’s Initials: _____Page 14 of 20
Improvements include but are not limited to:
•Construction of ultimate half-width street improvements adjacent to project frontage
on Central Avenue (Augmented Urban Arterial, 134-foot full-width right-of-way).
Improvements include but are not limited to road widening (AC pavement and base
material), curb and gutter, sidewalks, curb ramps, parkway landscaping, and
streetlights. Widening shall include transition paving and striping to match existing
conditions.
•Construction of ultimate half-width street improvements adjacent to project frontage
on N. Frontage Road (Local Road, 60-foot full-width right-of-way). Improvements
include but are not limited to road widening plus 12 feet (AC pavement and base
material), curb and gutter, sidewalks, curb ramps, parkway landscaping, and
streetlights.
•Construction of ultimate street improvements of El Toro Cut Off Road adjacent to
project limits. Improvements include but are not limited to road widening (AC
pavement and base material), curb and gutter, sidewalks, curb ramps, parkway
landscaping.
•Installation of traffic signals at the intersection of Central Ave (State Route 74) and
El Toro Cut Off Road including modification of signing and striping and installation
curb ramp to accommodate pedestrian crossing.
•Modification of existing and installation of new signing and striping for required
improvements. The project shall be responsible for any additional paving and/or
striping removal caused by the striping plan.
54.Project shall coordinate with Riverside Transit Authority (RTA) for location and installation
of bus transit facilities. Required bus stop improvements and/or relocation shall be shown
on plans submitted for project grading and development. Improvements are subject to
review and approval by the RTA. Improvements shall be installed prior to first occupancy.
55.Sight distance into and out at each project driveway shall comply with City or Caltrans
standards. Project shall ensure facilities are installed in the line of sight of drivers.
56.If existing improvements are to be modified, the existing improvement plans on file shall be
revised accordingly and approved by the City Engineer prior to issuance of a building
permit.
57.Project will be responsible to design and install streetlights along the project frontage.
Streetlight system shall be designed as LS-2B system. Streetlight plans shall include but
not limited to details such as location, pole and luminaire type, and pull box design.
Streetlight plans may be included as part of the Street Improvement Plans.
58.A registered Civil Engineer shall prepare the improvement, signing and striping, and traffic
signal plans required for this project. Improvements shall be designed and constructed to
City Standards and Codes (LEMC 12.04 and 16.34).
59.10-year storm runoff shall be contained within the curb and the 100-year storm runoff shall
be contained within the street right-of-way. When either of these criteria are exceeded,
drainage facilities shall be provided.
60.All drainage facilities in this project shall be constructed to Riverside County Flood Control
District Standards. All public storm drain improvements shall be constructed as part of the
PA 2021-25/CUP 2022-01/CUP 2022-04/CDR 2022-01 PC:
Conditions of Approval CC:
Applicant’s Initials: _____Page 15 of 20
first phase of the project.
61.A drainage study shall be provided. The study shall identify the following: identify storm
water runoff from and upstream of the site; show existing and proposed off-site and on-site
drainage facilities; and include a capacity analysis verifying the adequacy of the facilities.
The drainage system shall be designed to ensure that runoff from a 10-year storm of 6
hours and 24 hours duration under developed condition is equal or less than the runoff
under existing conditions of the same storm frequency. Both 6-hour and 24-hour storm
duration shall be analyzed to determine the detention requirements to accomplish the
desired results.
62.All natural drainage traversing the site shall be conveyed through the site, or shall be
collected and conveyed by a method approved by the City Engineer. All off-site drainage,
if different from historic flow, shall be conveyed to a public facility.
63.Roof drains shall not be allowed to outlet directly through coring in the street curb. Roofs
should drain to a landscaped area.
64.The site shall be planned and developed to keep surface water from entering buildings
(California Green Building Standards Code 4.106.3).
65.All existing storm drain inlet facilities adjacent to the subject properties shall be retrofitted
with a storm drain filter; all new storm drain inlet facilities constructed by this project shall
include a storm drain filter.
PERMITTING/CONSTRUCTION
66.An Encroachment Permit shall be obtained prior to any work on City right-of-way. The
applicant shall submit the permit application, required fees and executed agreements,
security and other required documentation prior to issuance.
67.All compaction reports, grade certification, monument certification (with tie notes delineated
on 8 ½ X 11” Mylar) shall be submitted to the Engineering Department before final inspection
of public works improvements will be scheduled and approved.
PRIOR TO GRADING PERMIT
Design
68.A grading plan signed and stamped by a California Registered Civil Engineer shall be
submitted for City review and approval for all addition and/or movement of soil (grading) on
site. The plan shall include separate sheets for erosion control, haul route and traffic control.
The grading plan submittal shall include all supporting documentation and be prepared using
City standard title block, standard drawings and design manual.
69.All grading plan contours shall extend to minimum of 50 feet beyond property lines to
indicate existing drainage pattern.
70.The grading plan shall show that no structures, landscaping, or equipment are located near
the project entrances that could reduce sight distance.
PA 2021-25/CUP 2022-01/CUP 2022-04/CDR 2022-01 PC:
Conditions of Approval CC:
Applicant’s Initials: _____Page 16 of 20
71.If the grading plan identifies alterations in the existing drainage patterns as they exit the site,
a Hydrology and Hydraulic Report for review and approval by City Engineer shall be required
prior to issuance of grading permits. All grading that modifies the existing flow patterns
and/or topography shall be in compliance with Federal, State and Local law and be approved
by the City Engineer.
72.A seismic study shall be performed on the site to identify any hidden earthquake faults,
liquefaction and/or subsidence zones present on-site. A certified letter from a registered
geologist or geotechnical engineer shall be submitted confirming the absence of this hazard
prior to grading permit. The location of faults, active or inactive shall be shown on the plan
sets.
73.Applicant shall obtain all necessary off-site easements and/or permits for off-site grading
and the applicant shall accept drainage from the adjacent property owners.
74.Applicant shall mitigate to prevent any flooding and/or erosion downstream caused by
development of the site and/or diversion of drainage.
75.All natural drainage traversing the site (historic flow) shall be conveyed through the site in a
manner consistent with the historic flow or to one or a combination of the following: to a
public facility; accepted by adjacent property owners by a letter of drainage acceptance; or
conveyed to a drainage easement as approved by the City Engineer.
Permit/Construction
76.Applicant shall execute and submit grading and erosion control agreement, post grading
security and pay permit fees as a condition of grading permit issuance.
77.No grading shall be performed without first having obtained a Grading Permit. A grading
permit does not include the construction of retaining walls or other structures for which a
Building Permit is required.
78.A preconstruction meeting with the City Engineering Inspector (Engineering Department) is
required prior to commencement of any grading activity.
79.Prior to commencement of grading operations, applicant is to provide to the City a map of
all proposed haul routes to be used for movement of export material. All such routes shall
be subject to the review and approval of the City Engineer. Haul route shall be submitted
prior to issuance of a grading permit. Hauling in excess of 5,000 cubic yards shall be
approved by the City Council (LEMC 15.72.065).
80.All grading shall be done under the supervision of a geotechnical engineer. Slopes steeper
than 2 to 1 shall be evaluated for stability and proper erosion control and approved by the
City.
81.Review and approval of the project sediment and erosion control plan shall be completed.
As warranted, a copy of the current SWPPP shall be kept at the project site and be
available for review upon request.
82.Approval of the project Final Water Quality Management Plan (WQMP) for post
construction shall be received prior to issuance of a grading permit.
PA 2021-25/CUP 2022-01/CUP 2022-04/CDR 2022-01 PC:
Conditions of Approval CC:
Applicant’s Initials: _____Page 17 of 20
83.Applicant shall obtain applicable environmental clearance from the Planning Department
and submit applicable clearance document to the Engineering Department. This approval
shall specify that the project complies with any and all required environmental mitigation
triggered by the proposed grading activity.
PRIOR TO BUILDING PERMIT
84.Provide soils, geology and seismic report, including recommendations for parameters for
seismic design of buildings, and walls prior to building permit.
85.All public improvement plans, traffic signal plans, signing and striping plans shall be
completed and approved by the City Engineer.
86.Parcel merger for APN’s 347-130-033 and 347-130-034 shall be recorded.
87.Any dedications, vacations, and easements shall be recorded with the recorded copy
provided to the City prior to issuance of the building permit.
88.Applicant shall pay all Capital Improvement, TIF, TUMF, and any outstanding plan check
and/or permit fees.
PRIOR TO OCCUPANCY / FINAL APPROVAL
89.All public improvements shall be completed in accordance with the approved plans or as
condition of this development to the satisfaction of the City Engineer.
90.Proof of acceptance of maintenance responsibility of slopes, open spaces, landscape areas,
and drainage facilities shall be provided.
91.Applicant shall provide a digital copy of the recorded Covenants, Conditions and Restrictions
(CC&Rs) to the Engineering Department.
92.As-built plans for all approved plan sets shall be submitted for review and approval by the
City. Applicant is responsible for revising the original mylar plans.
93.In the event of the damage to City roads from hauling or other construction related activity,
applicant shall pay full cost of restoring public roads to the baseline condition.
94.Final soil report showing compliance with recommendations, compaction reports, grade
certifications, monument certification (with tie notes delineated on 8 ½ X 11” Mylar) shall be
submitted in .tif format on a USB flash drive or electronically to the Engineering Department
before final inspection will be scheduled.
95.All required public right-of-way dedications, vacations and easement shall be recorded
with a recorded copy provided to the City prior to first occupancy.
96.Applicant shall pay all outstanding applicable processing and development fees prior to
occupancy and/or final approval.
97.Applicant shall submit documentation pursuant to City’s Security Release handout.
PA 2021-25/CUP 2022-01/CUP 2022-04/CDR 2022-01 PC:
Conditions of Approval CC:
Applicant’s Initials: _____Page 18 of 20
98.Applicant shall submit as-built all Engineering Department approved project plan sets.
After City approval of paper copy, the developer/owner is responsible for revising the
original mylar plans. Once the original mylars have been approved, the developer shall
provide the City with a digital copy of the “as-built” plans in .tif format. 124
99.Applicant shall provide AutoCAD and GIS Shape files of all Street and Storm Drain plans.
All data must be in projected coordinate system: NAD 83 State Plane California Zone VI
U.S. Fleet. All parts and elements of the designed system shall be represented discretely.
Include in the attribute table basic data for each feature, such as diameter and length, as
applicable, and for pipes include material (PVC, RCP, etc.) and slope.
CITY OF LAKE ELSINORE FIRE MARSHAL
100.The applicant/operator shall comply with all requirements of the Riverside County Fire
Department Lake Elsinore Office of the Fire Marshal. Questions should be directed to the
Riverside County Fire Department, Lake Elsinore Office of the Fire Marshal at 130 S. Main
St., Lake Elsinore, CA 92530. Phone: (951) 671-3124 Ext. 225.
101.This project is in a Very High Fire Hazard Severity Zone of Riverside County as shown on
a map on file with the Clerk of the Board of Supervisors. Any building constructed within
this project shall comply with special construction provisions contained in the California
Building Code.
102.The applicant or developer shall provide fire hydrants in accordance with the following:
i. Prior to placing any combustibles on site, provide an approved water source for
firefighting purposes.
ii. Prior to building permit issuance, submit plans to the water district for a water
system capable of delivering fire flow as required by the California Fire Code and
Fire Department standards. Fire hydrants shall be spaced in accordance with the
California Fire Code.
iii. Required fire flow is estimated to be 1,500 GPM at 20 PSI for a 2-hour duration
based on 2019 California Fire Code and 2,668 square foot building area with Type
V-B construction.
103.Prior to building permit issuance, install the approved water system and contact the Fire
Department for a verification inspection.
DEPARTMENT OF ADMINISTRATIVE SERVICES
Annex into the City of Lake Elsinore Community Facilities District No. 2015-2 (Maintenance
Services)
104.Prior to Building Permit issuance, the applicant shall annex into the Community Facilities
District No. 2015-2 (Maintenance Services) or current Community Facilities District in place
at the time of annexation to fund the on-going operation and maintenance of the public right-
of-way landscaped areas and neighborhood parks to be maintained by the City and for street
lights in the public right-of-way for which the City will pay for electricity and a maintenance
fee to Southern California Edison, including parkways, street maintenance, open space and
public storm drains constructed within the development and federal NPDES requirements
to offset the annual negative fiscal impacts of the project. Alternatively, the applicant may
propose alternative financing mechanisms to fund the annual negative fiscal impacts of the
PA 2021-25/CUP 2022-01/CUP 2022-04/CDR 2022-01 PC:
Conditions of Approval CC:
Applicant’s Initials: _____Page 19 of 20
project with respect to Maintenance Services. Applicant shall make a non-refundable
deposit of $15,000 or at the current rate in place at the time of annexation toward the cost
of annexation, formation or other mitigation process, as applicable.
PA 2021-25/CUP 2022-01/CUP 2022-04/CDR 2022-01 PC:
Conditions of Approval CC:
Applicant’s Initials: _____Page 20 of 20
I hereby state that I acknowledge receipt of the approved Conditions of Approval for the above
named project and do hereby agree to accept and abide by all Conditions of Approval as approved
by the Planning Commission of the City of Lake Elsinore on ________________. I also
acknowledge that all Conditions shall be met as indicated.
Date:
Applicant’s Signature:
Print Name:
Address:
Phone Number:
SH-74SUNBLAZE RDEL TO
RO CUTOFF
CARLA CTANABELL LNCRATER DRPROMISE RD
SONIA DRALTISSIMO WAYROSETTA CANYON RD
BRONZE STAR RDBLUE MOON ST
SH-74SUNBLAZE RDEL TO
RO CUTOFF
CARLA CTANABELL LNCRATER DRPROMISE RD
SONIA DRALTISSIMO WAYROSETTA CANYON RD
BRONZE STAR RDBLUE MOON ST
Planning Application No. 2021-25 APNs: 347-130-033, 034 & 035VICINITY MAP
PROJECT SITE
´
SH-74SUNBLAZE RDEL TO
RO CUTOFF
CARLA CTANABELL LNCRATER DRPROMISE RD
SONIA DRALTISSIMO WAYROSETTA CANYON RD
BRONZE STAR RDBLUE MOON ST
SH-74SUNBLAZE RDEL TO
RO CUTOFF
CARLA CTANABELL LNCRATER DRPROMISE RD
SONIA DRALTISSIMO WAYROSETTA CANYON RD
BRONZE STAR RDBLUE MOON ST
Planning Application No. 2021-25 APNs: 347-130-033, 034 & 035AERIAL MAP
PROJECT SITE
´
ALL REPORTS, PLANS AND
DOCUMENTS PREPARED BY MARKS
ARCHITECTS SHALL REMAIN THE
PROPERTY OF MARKS ARCHITECTS
AND IS INTENDED FOR USE FOR THIS
SPECIFIC PROJECT ONLY.
marks architects 2022
PLANNING SUBMITTAL 01.14.22
MK10B
ADDRESS:
MK TYPE:
JIB #:
MK10B
5497
ⒸSGOOTAESTRENEWAL DATE
CF FLAI12-30-2023 NRAIRKRBAC-31482
AEI M
ALICENS E D ARCH
I
TECTL
HWY 74 NS
EL TORO CUT OFF,
LAKE ELSINORE CA,
92532
TITLE
SHEET
TS1.0
GENERAL NOTES
DEFERRED SUBMITTALS
CONSULTANT INFORMATION
BUILDING DATALEGEND & ABBREVIATIONS
ALSO REFER TO LEGEND & ABBREVIATIONS ON CIVIL, SITE, PLUMBING, MECHANICAL, ELECTRICAL & KITCHEN DRAWINGS.
JT.or JNT JOINT
JIB or J.I.B.Jack in the Box, Inc.
JST.JOIST
L ANGLE
LB.or LB or # POUNDS
LG.LONG
MAT. MATERIAL
MAX. MAXIMUM
M.B. MACHINE BOLT
MECH.MECHANICAL
MEZZ. MEZZANINE
MFR.MANUFACTURER
MIN. MINIMUM
MISC. MISCELLANEOUS
MPH MILES PER HOUR
M.P.S. MODULAR PANELBOARD
SYSTEM
M.S.B. MAIN SWITCH BOARD
MTL. METAL
(N)NEW
NO. or # NUMBER
N.I.C.NOT IN CONTRACT
N.T.S. NOT TO SCALE
O.C. ON CENTER
O.F.C.I. OWNER FURNISHED,
CONTRACTOR INSTALLED
O.F.O.I.OWNER FURNISHED,
OWNER INSTALLED
O.H.OPPOSITE HAND
OPNG. OPENING
P.C. PLUMBING CONTRACTOR
PERP.PERPENDICULAR
P. LAM PLASTIC LAMINATE OR
PARALLAM (BEAM)
PL. PLATE
P.L. PROPERTY LINE
PLYWD. PLYWOOD
POS or P.O.S.POINT OF SALE
PR. PAIR
PSF. POUNDS PER SQ. FOOT
PSI. POUNDS PER SQ. INCH
P.T.PRESSURE TREATED
Q.T. QUARRY TILE
QTY. or QTY QUANTITY
RAD.OR (R) RADIUS
REINF. REINFORCEMENT
R.O.ROUGH ORIENTATION
S.C. SAW-CUT JOINT
SCHED. SCHEDULE
SHT. SHEET
SIM. SIMILAR
SM SHEET METAL
SMS SHEET METAL SCREW
SPEC.(S) SPECIFICATION(S)
SQ. SQUARE
SQ. IN. SQUARE INCH
SQ. FT. SQUARE FOOT
S.S.STAINLESS STEEL
STD. STANDARD
STL. STEEL
STRUCT. STRUCTURAL
SUSP. SUSPENDED
S.W.SHEARWALL
SYM. SYMMETRICAL
(T) TOP
TEMP. TEMPERED (TEMPERATURE)
T.G.TEMPERED GLASS
THK. THICKNESS
T & G TONGUE & GROOVE
T.N. TOE NAIL
T.O.TOP OF
T.O.B. TOP OF BEAM
T.O.C.TOP OF CURB
T.O.F. TOP OF FOOTING
T.O.PL. TOP OF PLATE
T.O.S. TOP OF SLAB
T.O.W. TOP OF WALL
TYP. TYPICAL
U.B.C. UNIFORM BUILDING CODE
U.O.N. UNLESS OTHERWISE NOTED
U.S.P. UNDER SEPARATE PERMIT
VERT. OR (V) VERTICAL
V.W.C. VINYL WALLCOVERING
W/ WITH
WD. WOOD
W.G.B. WATER RESISTANT GYPSUM
BOARD
W.I.B.WALK-IN or WALK IN BOX
WT. WEIGHT
WWM. WELDED WIRE MESH
&AND
@ AT
A.B.ANCHOR BOLT
A.C.ASPHALTIC CONCRETE
A.C.I.AMERICAN CONCRETE INSTITUTE
ACP ACOUSTIC CEILING PANEL
A.D.A.A.G. AMERICANS WITH DISABILITIES ACT
ACCESSIBILITY GUIDELINES
A.F.F. or AFF ABOVE FINISH FLOOR
ALUM. ALUMINUM
A.P.A. AMERICAN PLYWOOD ASSOCIATION
A.Q.T. ABRASIVE QUARRY TILE
ARCH. ARCHITECTURAL
A.S.T.M. AMERICAN SOCIETY FOR TESTING
MATERIALS
BLK'G or BLKG BLOCKING
B.N. BOUNDARY NAIL
A.O.BOTTOM OF
BM. BEAM
B.O.J. BOTTOM OF JOIST
B.U.R. BUILT UP ROOFING
BOTT. or (B)BOTTOM
C CONDUIT
C.L. or ℄CENTER LINE
C.B.B. CEMENTITIOUS BACKER BOARD
C.D.CORE DRILL
C.J. CONTROL JOINT (COLD JOINT)
CLG. CEILING
CLR. CLEAR
C.M.U.CONCRETE MASONRY UNIT
COL. COLUMN
CONC. CONCRETE
CONN. CONNECTION
CONST. CONSTRUCTION
CONST. JT. CONSTRUCTION JOINT
CONT. CONTINUOUS
CONTR. CONTRACTOR
COMP COMPACTED (ION)
C.T.CERAMIC TILE
DBL. DOUBLE
DEG. or ° DEGREE
DIA. or Ø DIAMETER
DIAG. DIAGONAL
DIM. DIMENSION
DR. DOOR
DWG.(S) DRAWING(S)
(E)EXISTING
EA. EACH
E.C. ELECTRICAL CONTRACTOR
E.F. EACH FACE
EL. or ELEV.ELEVATION
E.N. EDGE NAIL
E.O.C. EDGE OF COUNTER / EDGE OF
EQUIPMENT
ELEC.ELECTRICAL
EQ. or = EQUAL
EQUIP.EQUIPMENT
E.S. EACH SIDE
EXP. EXPANSION
EXT.EXTERIOR
FACT. FACTORY
F.D. FLOOR DRAIN
FDN. FOUNDATION
F.F. FINISHED FLOOR
F.F.L.FINISHED FLOOR LEVEL
F.G. FLOAT GLASS
FLR. FLOOR
FIN. FINISH
F.N. FIELD NAIL
F.O.B. FACE OF BEAM
F.O.F. FACE OF FINISH
F.O.J. FACE OF JOIST
F.O.M. FACE OF MASONRY
F.O.P. FACE OF POST
F.O.S. FACE OF STUD
F.R.P.FIBERGLASS REINFORCED PANEL
F.S.FLOOR SINK
FT. FOOT or FEET
FTG. FOOTING
GA. or GA GAUGE (GAGE)
G.B. or GYP. BD. GYPSUM BOARD
G.C. GENERAL CONTRACTOR
GALV. GALVANIZED
G.I. GALVANIZED IRON
GLB. GLUE-LAMINATED BEAM
H.D. HUB DRAIN
HDR. HEADER
HDW. HARDWARE
HGR. HANGER
HGT. or HT.HEIGHT
H.M. HOLLOW METAL
HORIZ. or H HORIZONTAL
H.S.B. HIGH STRENGTH BOLT
I.B.C.INTERNATIONAL BUILDING CODE
I.D.INTERIOR DESIGN
IN. INCH
INFO. INFORMATION
INT.INTERIOR
INV. INVERTED
OWNER: BESHAY FOODS
BUILDING ADDRESS: HWY 74 NS, EL TORO CUT OFF
LAKE ELSINORE CA, 92532
LEGAL JURISDICTION: CITY OF ELSINORE, COUNTY
OF RIVERSIDE
ASSESSOR'S PARCEL NO. 347-130-033, 347-130-034 AND 347-130-035
TYPE OF CONSTRUCTION: VB, NON-SPRINKLED
GROSS BUILDING AREA: 2,649 SQ. FT.
GROSS BUILDING AREA 624 SQ. FT.
TOTAL SITE AREA: 1.09 ACRES (JACK IN THE BOX)
0.36 ACRES (THE HUMAN BEAN)
BUILDING HEIGHT:23'-2"
BUILDING HEIGHT: 19'-6"
SEATING: 31 SEATS (INDOOR)
SEATING: 12 SEATS (OUTDOOR)
OCCUPANCY: A-2
OCCUPANCY: B
PARKING REQUIREMENTS: 26
PARKING REQUIREMENTS: 06
PARKING PROVIDED:26
PARKING PROVIDED:08
LANDSCAPE
SHEET INDEX
FLOOR PLAN
JACK IN THE BOX
A1.0
EXTERIOR ELEVATIONS
TS1.0
L1.0 LANDSCAPE CONCEPT PLAN
TITLE SHEET
(TOTAL OF 25 SHEETS)
SITE
SD1.0
SD2.0
SD1.2
SITE DETAILS
OVERALL SITE PLAN
THE HUMAN BEAN SITE PLAN
RIGID INSULATION
CONCRETE
GYPSUM BOARD
CERAMIC AND QUARRY TILE
ASPHALTIC CONCRETE PAVING
MASONRY
PLYWOOD
BATT INSULATION
EARTH GRADE
SAND BASE
INDICATES SHEARWALL LOCATIONS WHERE NO
CONDUIT OR PIPING WILL BE PERMITTED TO
PENETRATE SILL OR TOP PLATE. SEE PLANS FOR
ADDITIONAL NOTES.
KITCHEN
DOOR SYMBOL
SHEARWALL / ANCHOR BOLT SYMBOL
EQUIPMENT, SEE KITCHEN DRAWING
REVISION SYMBOL
FOOTING SYMBOL
INTERIOR ELEVATION
ELEVATION/DATUM MARK
EXTERIOR MATERIAL / FINISH
EXTERIOR COLOR
ROOM NAME
ROOM NUMBER
DETAIL NUMBER
SHEET NUMBER
WALL SECTION NUMBER / ELEV. NUMBER SHEET
NUMBER
BUILDING SECTION NUMBER
SHEET NUMBER
FINISHES & EQUIPMENT SEE ID DRAWINGS
KEY NOTES
DIMENSION TO EDGE / FACE OF OBJECT
DIMENSION TO CENTER LINE OF OBJECT
HWY 74 NS EL TORO CUT OFF,
LAKE ELSINORE CA 92532
MARKS ARCHITECTS, INC.
2643 FOURTH AVE.
SAN DIEGO, CA 92103
TEL: (619) 702-9448
CONTACT: GABRIELA MARKS
ARCHITECT CIVIL ENGINEER
4121 WESTERLY PLACE #112
NEWPORT BEACH, CA 92660
TEL:949.610.8997
CONTACT: BIANCA VILLANUEVA
EMAIL:bvillanueva@cdrwest.com
VICINITY MAP
PROJECT SITE
(JACK IN THE BOX)
A.
B.
C.
D.
E.
F.
G.
H.
J.
ALL WORK SHALL CONFORM TO THE 2019 EDITION OF THE CALIFORNIA BUILDING CODE, AND ALL OTHER
APPLICABLE CODES, STANDARDS, AND REGULATIONS OF CITY OF LAKE ELSINORE AND COUNTY OF RIVERSIDE.
IT IS INTENDED THAT A COMPLETE OCCUPIABLE BUILDING PROJECT IS PROVIDED.
DRAWINGS ARE BASED ON A SURVEY.
DO NOT SCALE THESE DRAWINGS. VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD. ANY
DISCREPANCIES IN THESE DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO
STARTING WORK.
ALL PROPOSED SUBSTITUTIONS SHALL BE APPROVED BY THE ARCHITECT, IN WRITING, PRIOR TO INSTALLATION.
PROVIDE EACH SUBCONTRACTOR WITH A COMPLETE AGENCY-PERMITTED DRAWING SET AT TIME
OF CONSTRUCTION.
ALL ABBREVIATIONS INCLUDED FOLLOW INDUSTRY STANDARDS. CONTACT ARCHITECT IF ANY ABBREVIATIONS ARE
NOT CLEAR.
GC SHALL SUPPLY AND INSTALL ALL ASPECTS OF THE PROJECT DESCRIBED IN THIS DRAWING SET UNLESS
OTHERWISE NOTED.
GRAPHIC AND WRITTEN INFORMATION ON DRAWINGS SHALL BE COORDINATED WITH ALL TRADES
PRIOR TO INSTALLATION.
“SUBMITTAL DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE REGISTERED DESIGN
PROFESSIONAL IN RESPONSIBLE CHARGE, WHO SHALL REVIEW THEM AND FORWARD THEM TO THE BUILDING
OFFICIAL WITH A NOTATION INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED
AND THAT THEY HAVE BEEN FOUND TO BE IN GENERAL CONFORMANCE WITH THE DESIGN OF THE BUILDING. THE
DEFERRED ITEMS SHALL NOT BE INSTALLED UNTIL THEIR DESIGN AND SUBMITTAL DOCUMENTS HAVE BEEN
APPROVED BY THE BUILDING OFFICIAL.”
K.
L.CG SHALL FIELD VERIFY ALL DIMENSIONS PRIOR TO STARTING CONSTRUCTION. NOTIFY ARCHITECT
OF ANY DISCREPANCIES.
LANDSCAPE ARCHITECT
APPLICABLE CODES
2019 CALIFORNIA BUILDING CODE
2019 CALIFORNIA ELECTRICAL CODE
2019 CALIFORNIA PLUMBING CODE
2019 CALIFORNIA MECHANICAL CODE
2019 CALIFORNIA FIRE CODE
2019 CALIFORNIA GREEN CODE
TITLE 24 AND ALL APPLICABLE COUNTY ORDINANCES
SIGNAGE
DRIVE-THRU EQUIPMENT
CANOPIES AND AWNINGS
TRUSSES
SOILS
2 DRIVE THRU RESTAURANTS
SCOPE OF WORK
·GROUND UP JACK IN THE BOX, DRIVE THRU RESTAURANT AND RELATED SITE IMPROVEMENTS.
·GROUND UP THE HUMAN BEAN, DRIVE THRU RESTAURANT AND RELATED SITE
IMPROVEMENTS.
PROJECTS:
1 - JACK IN THE BOX
2 - THE HUMAN BEAN
1
2
1
2
1
2
1
2
A1.2
EXTERIOR ELEVATIONSA1.1
SD1.1 JACK IN THE BOX SITE PLAN
EL TORO DEVELOPMENT
SD2.1 SITE DETAILS
PROJECT SITE
(THE HUMAN BEAN)
1
2
L1.1 LANDSCAPE CONCEPT PLAN
L1.2 PLANTING NOTES AND DETAILS
THE HUMAN BEAN
FLOOR PLANA2.0
EXTERIOR ELEVATIONSA2.1
CIVIL
CG.01 CONCEPTUAL GRADING
CG.03
CG.04
CG.05
CONCEPTUAL WET UTILITIES PLAN
SECTIONS
SECTIONS
BUILDING SECTIONSA1.3
PLANNING 1ST CORR. 06.28.221
MATERIAL AND COLORS INFORMATIONA3.0 1
CG.06 SIGHT DISTANCE EXHIBIT
SHEET 1 ALTA/NSPS LAND TITLE SURVEY
SHEET 2 ALTA/NSPS LAND TITLE SURVEY
SOTELO LANDSCAPE ARCHITECTS
2643 FOURTH AVE.
SAN DIEGO, CA 92103
CONTACT: ANGELINA SOTELO
PHONE:619.719.6756
PETRA GEOSCIENCES
3186 AIRWAY AVE SUITEK
COSTA MESA, CA 92626
CONTACT:BIANCA VILLANUEVA
PHONE:714.549.89.21
PLANNING 2ND CORR. 10.31.222
CG.02 CONCEPTUAL GRADING
CG.07 MAINTENANCE EXHIBIT
14101420
14301440
14501420
1420143014401430
1430
1420
14301440
DIRT
ROAD
POWER POLE
FIRE HYDRANT
POWER POLE
POWER POLE
POWER POLE
POWER POLE
POWER POLE
POWER POLE
WATER VALVE
FIRE HYDRANT
BACK FLOW DEVICE
EDISON VAULT
COMM MH
DEAD END
SIGN
TRAFFIC
SIGNAL BOX
UTILITY
BOX
SIGN
WATER
VALVE
ST NAME SIGN
STOP
SIGN
3' DIA. STAND PIPE
FL 1427.44
SIGNAL LIGHT SIGN
BUS STOP SIGN BENCH
TRAFFIC
SIGNAL BOX
ST NAME
SIGNTRAFFIC
SIGNAL BOX
TRAFFIC
SIGNAL BOX
DIRT
WALKING
PATH
STOP
SIGN
HEAD
WALL
HEAD
WALL
STOP
SIGN
ST NAME
SIGN
WATER
VALVE
FL 1421.30
FL 1421.26
FL 1424.9824" CMP24" CMP
FRONT
A
G
E
R
O
A
D
HIGHWAY 74 EL TORO CUT OFF RDN14°21'3
4
"
E
3
8
7
.
9
4'
N26°04'00"E 229.00
'N64°20'02"W 124.88'N09°37'26
"
W33.67'N86°18'05"E31.75'N58°57'31"W (R)
∆=07° 12' 32" R = 3266.60' L=411.00'∆=04° 12' 47" R = 1034.25' L=76.05'∆=13° 14' 57" R = 686.71' L=158.00'
∆=11° 23'
4
5
"
R
=
6
6
6
.
7
1'
L
=
1
3
2
.
6
1
'N81°
39
'22
"E31.97
'
∆=05° 04' 40" R
=
3
2
6
6
.
6
0
'
L
=
2
8
9
.
5
0
'
∆=0
5
°
4
2
'
4
5
"
R =
6
8
6
.
7
1
'
L=6
8
.
4
7
'N83
°29
'
46
"E
6
2
.58
'
N58
°
0
9
'
3
2
"
E
1
1
4
.
2
1
'
N01°2
3'
3
6"
E
30.48'
∆=96° 28' 50"
R = 46.40'
L=78.13'∆=03° 31' 39" R = 934.25' L=57.52'N64°14'50"W (R)
FR
O
N
T
A
G
E
R
O
A
D
XS58
°
0
4
'
5
9
"
W
1
2
0
.
3
2
'
∆=05° 03' 43" R = 3267.
0
0
'
L
=
2
8
8
.
6
3
'
1
4
624 S.F.
180 S.F.
50'-0"
50'-0"NOPARKING50'-0"
23
8
1 2 320'-0
"41'-8"
21'-5"30'
-0
"
FF=28.72
PAD=28.22NOPARKING
VAN∆=07° 12' 59" R = 3267.00' L=411.48
'
N26°04'00"E 227.
0
7
'
MK 10B 2,649 SF
1 2 3 4
5
6
7
8
9111213
456789101112131415161718
22232425262728
20' LANDSCAPE SETB
A
C
K
19
1
2
3
20' LAN
D
S
C
A
P
E
S
E
T
B
A
C
K
50'-0
"50'-0
"28'-0
"
32'-01
2"
2930
24'-0
"
2021
ALL REPORTS, PLANS AND
DOCUMENTS PREPARED BY MARKS
ARCHITECTS SHALL REMAIN THE
PROPERTY OF MARKS ARCHITECTS
AND IS INTENDED FOR USE FOR THIS
SPECIFIC PROJECT ONLY.
marks architects 2022
PLANNING SUBMITTAL 01.14.22
MK10B
ADDRESS:
MK TYPE:
JIB #:
MK10B
5497
ⒸSGOOTAESTRENEWAL DATE
CF FLAI12-30-2023 NRAIRKRBAC-31482
AEI M
ALICENS E D ARCH
ITECTL
HWY 74 NS
EL TORO CUT OFF,
LAKE ELSINORE CA,
92532
SITE PLAN ASCALE: 1"=40'-0"
OVERALL
SITE PLAN
SD1.0
AS NOTED
EXISTING SETBACK
PROPERTY BOUNDARY LINE
SITE LEGEND
PROPOSED ASPHALT PAVING
PROPOSED CONCRETE PAVING
PROPOSED SIDEWALK
CURB RAMPS
EXISTING STREET LIGHT
PROPOSED SITE LIGHTING
BUILDING ENTRANCE
ACCESSIBLE PARKING SPACES
PROPOSED TRANSFORMER LOCATION
PROPOSED WATER METER LOCATION
PROPOSED GREASE INTERCEPTOR LOCATION
NUMBER OF PARKING STALLS
PROPERTY LINE
VEHICLE STACKING
LIMITS OF WORK
GENERAL CONDITIONS
GENERAL CONTRACTOR SHALL NOTE THAT ALL WORK
TO BE DONE SUCH AS EXCAVATIONS, TRENCHES,
CAISSONS, WALLS, ETC., AS INDICATED ON DRAWINGS,
IS SHOWN WITHOUT KNOWLEDGE OF UNDERGROUND
UTILITIES ON THIS PARTICULAR SITE. THE ARCHITECT
AND OWNER ASSUME NO RESPONSIBILITY FOR
DETERMINING THEIR LOCATION, SIZE, DEPTH, OR
HAZARD.
GENERAL NOTES
2. GENERAL CONTRACTOR SHALL PROVIDE, AS
REQUESTED BY CONSTRUCTION MANAGER, 'COMING
SOON' SIGNAGE. 9/SD2.1
3. ALL SITE CONCRETE PAVING SHALL BE SPRAYED
WITH A CURING COMPOUND AS SOON AS CONCRETE
IS SET UP.
, SEE DETAIL
4.GENERAL CONTRACTOR SHALL PROVIDE 12"x12" LANDSCAPE PAVERS
AT WINDOWS WHEN LANDSCAPE IS PROVIDED AROUND WINDOW
AREAS.
REFERENCE TRUE
SEE SHEET SD1.1 SEE SHEET SD1.2
DEVELOPMENT SUMMARY
JACK IN THE BOX PARCEL
SITE
LANDSCAPE
BUILDING
ASPHALT
THE HUMAN BEAN PARCEL
SITE
LANDSCAPE
BUILDING
ASHPHALT
47,989 S.F. (100%)
21,976 S.F. (45.80%)
2,649 S.F. (5.50%)
20,444 S.F. (42.60%)
WALKWAY 2,920 S.F. (6.10%)
15,981 S.F. (100%)
3,963 S.F. (25%)
624 S.F. (4 %)
10,399 S.F. (65%)
WALKWAY 905 S.F. (6 %)
PLANNING 1ST CORR. 06.28.221
1
1 EXISTING FIRE HYDRANT
1
KEY NOTES
2 PROPOSED FIRE HYDRANT .
1
1
1
1
1
TRAFFIC LIGHT
14161432
1416
14281428
14261424
1422
1422
1418
1416141814361434143214381428142614241422141414121426
14
2
6
14
2
4
14281424
14221414141214081406140414021418143414101420
14301420
14201430141014401430
1430
14001420
DIRT
ROAD
POWER POLE
POWER POLE
POWER POLE
POWER POLE
POWER POLE
POWER POLE
TRAFFIC
SIGNAL BOX
UTILITY
BOX
SIGN
WATER
VALVE
ST NAME SIGN
STOP
SIGN
3' DIA. STAND PIPE
FL 1427.44
SIGNAL LIGHT SIGN
BUS STOP SIGN BENCH
TRAFFIC
SIGNAL BOX
ST NAME
SIGNTRAFFIC
SIGNAL BOX
TRAFFIC
SIGNAL BOX
ST
LIGHT
DIRECTION SIGN
TRAFFIC SIGNAL
DIRT
WALKING
PATH
STOP
SIGN
HEAD
WALL
WALL
STOP
SIGN
ST NAME
SIGN
WATER
VALVE
FL 1424.9824" CMP24"
CMP30'FRONT
A
G
E
R
O
A
D
HIGHWAY 74 EL TORO CUT OFF RDROSETTA CANYON DRN14°21'
3
4
"
E
3
8
7.
9
4'
N26°04'00"E 229.00
'N64°20'02"W 124.88'N09°37'
2
6
"
W33.67'N86°18'05"E31.75'N58°57'31"W (R)
∆=07° 12' 32" R = 3266.60' L=411.00'∆=04° 12' 47" R = 1034.25' L=76.05'∆=13° 14' 57" R = 686.71' L=158.00'
∆=11° 23
'
4
5
"
R
=
6
6
6
.
7
1'
L
=
1
3
2
.
6
1'
EX. WATER LINE
FROM AS BUILT EVMWD
SHT 4209 N81°39
'22
"E31.97
'
N01°2
3'
3
6"
E
30.48'∆=03° 31' 39" R = 934.25' L=57.52'N64°14'50"W (R)
SD
4'-6"
20'-52
10'-91
2"
7'-0"8'-6"20'-0
"18'-0"33'-1"4'-7"54'-10"6'-2"21'-8"19'-11"24'-10"4'-6"21'-11"9'-0"8'-0"9'-0"9'-0"12'-9"18 SPACES @ 9'-0"
26'-8"
26'-11"
30'-0"
9 SPACES @ 9'-0"
19'-0"
2'-0"
13'-11"41'-8"R30'-6"R
3
0
'
-
6
"
LOT AREA:
1.09 ACRES 13'-0"12'-0"12'-0"21'-5"7'-0"30'-0
"
FF=28.72
PAD=28.22NOPARKING
VAN∆=07° 12' 59" R = 3267.00' L=4
1
1
.
4
8
'
N26°04'00"E 227.0
7
'NOPARKINGMK 10B
2,649 SF
1 2 3 4
5
6
7
8
9111213
50'-0"
50'-0"22'-0"39'-512"456789101112131415161718
22232425262728
20' LANDSCAPE SE
T
B
A
C
K
19
1
2
324'-0"18'-0"20' LAN
D
S
C
A
P
E
S
E
T
B
A
C
K
5'-5"6'-2"66'-8"11'-6"11'-312"50'-0"50'-0
"31'-6"28'-0"24'-6"32'-01
2"19'-9"2930
24'-0"
2021 4'-10"ALL REPORTS, PLANS AND
DOCUMENTS PREPARED BY MARKS
ARCHITECTS SHALL REMAIN THE
PROPERTY OF MARKS ARCHITECTS
AND IS INTENDED FOR USE FOR THIS
SPECIFIC PROJECT ONLY.
marks architects 2022
PLANNING SUBMITTAL 01.14.22
MK10B
ADDRESS:
MK TYPE:
JIB #:
MK10B
5497
ⒸSGOOTAESTRENEWAL DATE
CF FLAI12-30-2023 NRAIRKRBAC-31482
AEI M
ALICENS E D ARCH
ITECTL
HWY 74 NS
EL TORO CUT OFF,
LAKE ELSINORE CA,
92532
SITE PLAN ASCALE: 1"=10'-0"
SITE
PLAN
SD1.1
1"=10'-0"
REFERENCE TRUE
EXISTING SETBACK
PROPERTY BOUNDARY LINE
SITE LEGEND
PROPOSED ASPHALT PAVING
PROPOSED CONCRETE PAVING
PROPOSED SIDEWALK
CURB RAMPS
EXISTING STREET LIGHT
PROPOSED SITE LIGHTING
BUILDING ENTRANCE
ACCESSIBLE PARKING SPACES
PROPOSED TRANSFORMER LOCATION
PROPOSED WATER METER LOCATION
PROPOSED GREASE INTERCEPTOR LOCATION
NUMBER OF PARKING STALLS
PROPERTY LINE
VEHICLE STACKING
LIMITS OF WORK
GENERAL CONDITIONS
GENERAL CONTRACTOR SHALL NOTE THAT ALL WORK
TO BE DONE SUCH AS EXCAVATIONS, TRENCHES,
CAISSONS, WALLS, ETC., AS INDICATED ON DRAWINGS,
IS SHOWN WITHOUT KNOWLEDGE OF UNDERGROUND
UTILITIES ON THIS PARTICULAR SITE. THE ARCHITECT
AND OWNER ASSUME NO RESPONSIBILITY FOR
DETERMINING THEIR LOCATION, SIZE, DEPTH, OR
HAZARD.
GENERAL NOTES
1. REFER TO THE ACCESSIBILITY AND DIMENSIONING
PLAN, SHEET SD1.1, FOR HORIZONTAL CONTROL
INFORMATION AND JOINT DETAILING.
2. GENERAL CONTRACTOR SHALL PROVIDE, AS
REQUESTED BY CONSTRUCTION MANAGER, 'COMING
SOON' SIGNAGE. 9/SD2.1
3. ALL SITE CONCRETE PAVING SHALL BE SPRAYED
WITH A CURING COMPOUND AS SOON AS CONCRETE
IS SET UP.
, SEE DETAIL
4.GENERAL CONTRACTOR SHALL PROVIDE 12"x12" LANDSCAPE PAVERS
AT WINDOWS WHEN LANDSCAPE IS PROVIDED AROUND WINDOW
AREAS.
KEY NOTES
1
2
INSTALL ASPHALT PAVING; REFER TO THE 'PAVING SECTION THICKNESS' TABLE THIS
INSTALL CONCRETE PAVING; REFER TO THE 'PAVING SECTION THICKNESS' TABLE THIS
SHEET AND GEOTECHNICAL RECOMMENDATIONS UNDER SEPARATE COVER.
SHEET AND GEOTECHNICAL RECOMMENDATIONS UNDER SEPARATE COVER.
3 PROVIDE THICKENED CONCRETE EDGE AT PAVING INTERFACE; SEE DETAIL 8/SD2.0.
4 CONSTRUCT CONCRETE CURB AND GUTTER; SEE DETAIL 1/SD2.0.
5 CONSTRUCT CONCRETE CURB AT ASPHALT PAVING; SEE DETAIL 2/SD2.0.
6 CONSTRUCT CONCRETE CURB AT CONCRETE PAVING; SEE DETAIL 3/SD2.0.
7 CONSTRUCT MONOLITHIC CONCRETE CURB AND SIDEWALK; SEE DETAIL 4/SD2.0.
8 CONSTRUCT MONOLITHIC CONCRETE CURB AND PAVING; SEE DETAIL 5/SD2.0.
9 CONSTRUCT CONCRETE CURB AT BUILDING SIDE OF DRIVE-THRU LANE; SEE
DETAIL 6/SD2.0.
10
11
12 INSTALL CONCRETE CROSS PAN (DRIVE APPROACH) TO MUNICIPALITY STANDARDS.
13
14 EXISTING BUS STOP.
15
16 CONSTRUCT FLARE SIDED (WINGED) CURB RAMP; SEE DETAIL 13/SD2.0.
17 CONSTRUCT IN-LINE CURB RAMP; SEE DETAIL 14/SD2.0.
18 PROVIDE RAMP AND LANDINGS AT HANDICAP ACCESSIBLE PARKING SPACES; SEE
DETAIL 15/SD2.0.
19 CONSTRUCT DELIVERY RAMP; SEE DETAIL 17/SD2.0.
20 PROVIDE PUBLIC RIGHT-OF-WAY ACCESS RAMPS PER THE MUNICIPALITY STANDARDS.
21 INSTALL LIGHT POLE BASE; SEE DETAIL 16/SD2.1. REFER TO SHEET ES1.1 FOR
POLE AND FIXTURE REQUIREMENTS.
22 INSTALL CONCRETE WHEEL STOP TYPICAL AT HANDICAP SPACES AND STANDARD
SPACES FRONTING 6-FOOT OR LESSER WIDTH SIDEWALKS; SEE DETAIL 9/SD2.0.
23 INSTALL BARRIER POSTS AT PREVIEW BOARD, MENU BOARD, AND PERIPHERAL TO
BUILDING CORNERS; SEE DETAIL 4/SD2.1. CONTRACTOR TO PROVIDE SLEEVES
THROUGH CURB AND GUTTER WHERE APPROPRIATE. SEE ALSO SHEETS SD2.1
AND A1.0 FOR DIMENSIONING CONTROL.
24 INSTALL DETECTOR LOOP FOR ORDER BOARD; SEE DETAIL 18/SD2.1.
25 INSTALL DETECTOR LOOP AT PICK UP WINDOW; SEE DETAIL 10/SD2.1.
26
27 INSTALL PREVIEW BOARD; SEE DETAIL 20/SD2.0.
28 INSTALL ORDER BOARD; SEE DETAIL 18/SD2.1.
29 CONSTRUCT MASONRY BLOCK TRASH ENCLOSURE; SEE DETAIL 6/SD2.2.
30 SITE 'ENTRY' SIGN UNDER SEPARATE COVER. GENERAL CONTRACTOR REFER TO
SHEET ES1.0 FOR CONDUIT AND WIRING REQUIREMENTS.
31 SITE 'DRIVE-THRU' SIGN UNDER SEPARATE COVER. GENERAL CONTRACTOR REFER TO
SHEET ES1.0 FOR CONDUIT AND WIRING REQUIREMENTS.
32 SITE 'THANK YOU/DO NOT ENTER' SIGN UNDER SEPARATE COVER. GENERAL
CONTRACTOR REFER TO SHEET ES1.0 FOR CONDUIT AND WIRING REQUIREMENTS.
33 INSTALL HEIGHT CLEARANCE (9'-0") AND WARNING POLE SIGN; SEE DETAIL 20/SD2.1.
34 INSTALL ACCESSIBLE PARKING SIGN. SEE DETAIL 8/SD2.1.
35 60 S.F. MONUMENT SIGN, 6'-0" HIGH POLE SIGN.
36 APPLY INTERNATIONAL SYMBOL OF ACCESSIBILITY DECAL ON DOOR.
37 PAINT 4-INCH SOLID WHITE PARKING STRIPES TO MUNICIPALITY STANDARDS.
38 PAINT ACCESSIBLE PARKING SYMBOLS, TEXT, AND DIAGONALS; SEE DETAIL 6/SD2.1.
39
40 PAINT TRAFFIC DIRECTIONAL ARROWS; SOLID WHITE AND TYPICAL AS SHOWN.
41 PAINT 18-INCH WIDE SOLID WHITE CROSS WALK STRIPES AT 5-FEET (MAX) O.C.
42
43
44 PROPOSED WATER METER, CONTRACTOR TO COORDINATE WITH THE APPROPRIATE
UTILITY PROVIDER.
45 PROVIDE SCHEDULE 40 PVC SLEEVES AT 2X DIAMETER OF PROPOSED IRRIGATION
PIPING; TYPICAL OF ALL LANDSCAPE AREAS. REFER TO SHEET I1.1.
PROPOSED GREASE INTERCEPTOR, CONTRACTOR TO COORDINATE WITH THE
APPROPRIATE UTILITY PROVIDER.
PROPOSED TRANSFORMER LOCATION, CONTRACTOR TO COORDINATE WITH THE
APPROPRIATE UTILITY PROVIDER. BOLLARDS INSTALLED PER PROVIDER STANDARDS.
REFER TO SHEETS PS1.0 AND ES1.0.
PROPOSED SWITCHGEAR, CONTRACTOR TO COORDINATE WITH THE APPROPRIATE
UTILITY PROVIDER. REFER TO SHEET PS1.0.
PROPOSED GAS METER LOCATION, CONTRACTOR TO COORDINATE WITH THE
APPROPRIATE UTILITY PROVIDER. BOLLARDS INSTALLED PER PROVIDER STANDARDS.
REFER TO SHEETS PS1.0 AND P3.0.
INSTALL U-BAR BIKE RACK(S); SEE DETAIL 5/SD2.1.
INSTALL ACCESSIBLE PARKING SIGN WITH 'VAN' PLACARD. SEE DETAIL 8/SD2.1.
PROPOSED DRIVE-UP WASTE CHUTE.
PROVIDE TRASH RECEPTACLE. LOCATE AS REQUIRED FOR SITE CONDITIONS.
TOW AWAY SIGN PER LOCAL CODES.
26 PROPOSED SWITCHGEAR, CONTRACTOR TO COORDINATE WITH THE APPROPRIATE
UTILITY PROVIDER. REFER TO SHEET PS1.0.
46 ACCESSIBILITY PATH OF TRAVEL FROM ACCESSIBLE AISLE.
JACK IN THE BOX PARKING REQUIREMENTS
THE PARKING REQUIRED:
930/45 SQ FT OF DINNING = 21
1,719/200 SQ FT OF KITCHEN = 9
30 SPACES
PARKING PROVIDED:
ACCESSIBLE PARKING = 2 SPACES
STANDARD PARKING = 24 SPACES
TOTAL PARKING PROVIDED = 26 SPACES
38
41
2219
20
1
1
1
47
1
FIRE HYDRANT
34A
FREESTANDING SIGN AREA CALCULATIONS
TOTAL SITE FRONTAGE : 673 S.F.
ALLOWABLE AREA 20 S.F. PER 100 F.T. OF
FRONTAGE. NOT EXCEED 60 S.F.
GROUND SIGN PROVIDED:
60 S.F. 6' ABOVE PUBLIC SIDEWALK.
SIGNAGE CALCULATION
1
47 TRAFFIC LIGHT.
47
2
PLANNING 1ST CORR. 06.28.221
PLANNING 2ND CORR. 10.31.222
2
DEVELOPMENT SUMMARY
JACK IN THE BOX PARCEL
SITE
LANDSCAPE
BUILDING
ASPHALT
47,989 S.F. (100%)
21,976 S.F. (45.80%)
2,649 S.F. (5.50%)
20,444 S.F. (42.60%)
WALKWAY 2,920 S.F. (6.10%)
2
2
2
49 PATH OF TRAVEL.
TRANSITION AND JOIN TO
PROVIDE AC PAVEMENT
EXISTING PAVEMENT.2
2
2
FLOOR AREA RATIO
JACK IN THE BOX
FAR = 2,649 S.F.
47,480.4 S.F.
= 0.05
2
GROSS LOT AREA: 47,480 S.F.
NET LOT AREA: 47,480 S.F.
1440
145014401430
1430 14301440
1450
POWER POLE
WATER VALVE
FIRE HYDRANT
BACK FLOW DEVICE
EDISON VAULT
COMM MH
DEAD END
SIGN
TRAFFIC
SIGNAL BOX
UTILITY
BOX
SIGN
WATER
VALVE
HEAD
WALL
STOP
SIGN
ST NAME
SIGN
FL 1424.9824" CMP24"
CMPEL TORO CUT OFF RDN81°39
'22
"E31.97
'
∆=05° 04' 40"
R
=
3
2
6
6
.
6
0
'
L
=
2
8
9
.
5
0
'
∆=0
5
°
4
2
'
4
5
"
R =
6
8
6
.
7
1
'
L=6
8
.
4
7
'N83°29
'46
"E
62
.58
'
N5
8
°
0
9
'
3
2
"
E
1
1
4
.
2
1
'
N01°2
3'
3
6"
E
30.48'
∆=96° 28' 50"
R = 46.40'
L=78.13'∆=03° 31' 39" R = 934.25' L=57.52'18'-0"1'-412"12'-0"12'-2"6'-6"30'-812"4'-812"4'-6"4'-6"
EXISTING PROPERTY
LINE TO BE RELOCATED
10'-91
2"5'-0"XXS58
°
0
4
'
5
9
"
W
1
2
0
.
3
2
'
∆=05° 03' 43" R = 32
6
7
.
0
0
'
L
=
2
8
8
.
6
3
'NOPARKING50'-0"
50'-0"66'-6"123
8 30'-0"1 2 43
7'-512"624 S.F.13'-712"R8
'
-
0
"18'-0"11'-7"8'-0"20'-51
2"
180 S.F.
ALL REPORTS, PLANS AND
DOCUMENTS PREPARED BY MARKS
ARCHITECTS SHALL REMAIN THE
PROPERTY OF MARKS ARCHITECTS
AND IS INTENDED FOR USE FOR THIS
SPECIFIC PROJECT ONLY.
marks architects 2022
PLANNING SUBMITTAL 01.14.22
MK10B
ADDRESS:
MK TYPE:
JIB #:
MK10B
5497
ⒸSGOOTAESTRENEWAL DATE
CF FLAI12-30-2023 NRAIRKRBAC-31482
AEI M
ALICENS E D ARCH
ITECTL
HWY 74 NS
EL TORO CUT OFF,
LAKE ELSINORE CA,
92532
SITE PLAN ASCALE: 1"=20'-0"
SITE
PLAN
SD1.2
1"=20'-0"
EXISTING SETBACK
PROPERTY BOUNDARY LINE
SITE LEGEND
PROPOSED ASPHALT PAVING
PROPOSED CONCRETE PAVING
PROPOSED SIDEWALK
CURB RAMPS
EXISTING STREET LIGHT
PROPOSED SITE LIGHTING
BUILDING ENTRANCE
ACCESSIBLE PARKING SPACES
PROPOSED TRANSFORMER LOCATION
PROPOSED WATER METER LOCATION
PROPOSED GREASE INTERCEPTOR LOCATION
NUMBER OF PARKING STALLS
PROPERTY LINE
VEHICLE STACKING
LIMITS OF WORK
GENERAL CONDITIONS
GENERAL CONTRACTOR SHALL NOTE THAT ALL WORK
TO BE DONE SUCH AS EXCAVATIONS, TRENCHES,
CAISSONS, WALLS, ETC., AS INDICATED ON DRAWINGS,
IS SHOWN WITHOUT KNOWLEDGE OF UNDERGROUND
UTILITIES ON THIS PARTICULAR SITE. THE ARCHITECT
AND OWNER ASSUME NO RESPONSIBILITY FOR
DETERMINING THEIR LOCATION, SIZE, DEPTH, OR
HAZARD.
GENERAL NOTES
1. REFER TO THE ACCESSIBILITY AND DIMENSIONING
PLAN, SHEET SD1.1, FOR HORIZONTAL CONTROL
INFORMATION AND JOINT DETAILING.
2. GENERAL CONTRACTOR SHALL PROVIDE, AS
REQUESTED BY CONSTRUCTION MANAGER, 'COMING
SOON' SIGNAGE. 9/SD2.1
3. ALL SITE CONCRETE PAVING SHALL BE SPRAYED
WITH A CURING COMPOUND AS SOON AS CONCRETE
IS SET UP.
, SEE DETAIL
4.GENERAL CONTRACTOR SHALL PROVIDE 12"x12" LANDSCAPE PAVERS
AT WINDOWS WHEN LANDSCAPE IS PROVIDED AROUND WINDOW
AREAS.
KEY NOTES
1
2
INSTALL ASPHALT PAVING; REFER TO THE 'PAVING SECTION THICKNESS' TABLE THIS
INSTALL CONCRETE PAVING; REFER TO THE 'PAVING SECTION THICKNESS' TABLE THIS
SHEET AND GEOTECHNICAL RECOMMENDATIONS UNDER SEPARATE COVER.
SHEET AND GEOTECHNICAL RECOMMENDATIONS UNDER SEPARATE COVER.
3 CONSTRUCT CONCRETE CURB AT ASPHALT PAVING; SEE DETAIL 2/SD2.0.
4 CONSTRUCT CONCRETE CURB AT CONCRETE PAVING; SEE DETAIL 3/SD2.0.
5 CONSTRUCT MONOLITHIC CONCRETE CURB AND SIDEWALK; SEE DETAIL 4/SD2.0.
6 CONSTRUCT CONCRETE CURB AT BUILDING SIDE OF DRIVE-THRU LANE; SEE
DETAIL 6/SD2.0.
7
8 INSTALL CONCRETE CROSS PAN (DRIVE APPROACH) TO MUNICIPALITY STANDARDS.
9
10 CONSTRUCT IN-LINE CURB RAMP; SEE DETAIL 14/SD2.0.
11 PROVIDE RAMP AND LANDINGS AT HANDICAP ACCESSIBLE PARKING SPACES; SEE
DETAIL 15/SD2.0.
12 INSTALL LIGHT POLE BASE; SEE DETAIL 16/SD2.1. REFER TO SHEET ES1.1 FOR
POLE AND FIXTURE REQUIREMENTS.
13 INSTALL CONCRETE WHEEL STOP TYPICAL AT HANDICAP SPACES AND STANDARD
SPACES FRONTING 6-FOOT OR LESSER WIDTH SIDEWALKS; SEE DETAIL 9/SD2.0.
14 INSTALL BARRIER POSTS AT PREVIEW BOARD, MENU BOARD, AND PERIPHERAL TO
BUILDING CORNERS; SEE DETAIL 4/SD2.1. CONTRACTOR TO PROVIDE SLEEVES
THROUGH CURB AND GUTTER WHERE APPROPRIATE. SEE ALSO SHEETS SD2.1
AND A1.0 FOR DIMENSIONING CONTROL.
15 INSTALL DETECTOR LOOP FOR ORDER BOARD; SEE DETAIL 18/SD2.1.
16 INSTALL DETECTOR LOOP AT PICK UP WINDOW; SEE DETAIL 10/SD2.1.
17
18 INSTALL ORDER BOARD; SEE DETAIL 18/SD2.1.
19 CONSTRUCT MASONRY BLOCK TRASH ENCLOSURE; SEE DETAIL 6/SD2.2.
20 SITE 'DRIVE-THRU' SIGN UNDER SEPARATE COVER. GENERAL CONTRACTOR REFER TO
SHEET ES1.0 FOR CONDUIT AND WIRING REQUIREMENTS.
21 SITE 'THANK YOU/DO NOT ENTER' SIGN UNDER SEPARATE COVER. GENERAL
CONTRACTOR REFER TO SHEET ES1.0 FOR CONDUIT AND WIRING REQUIREMENTS.
22 INSTALL HEIGHT CLEARANCE (9'-0") AND WARNING POLE SIGN; SEE DETAIL 20/SD2.1.
24 6'-0" HIGH POLE SIGN.
25 PAINT 4-INCH SOLID WHITE PARKING STRIPES TO MUNICIPALITY STANDARDS.
26 PAINT ACCESSIBLE PARKING SYMBOLS, TEXT, AND DIAGONALS; SEE DETAIL 6/SD2.1.
27
28
PAINT TRAFFIC DIRECTIONAL ARROWS; SOLID WHITE AND TYPICAL AS SHOWN.
29
PAINT 18-INCH WIDE SOLID WHITE CROSS WALK STRIPES AT 5-FEET (MAX) O.C.
30
31 PROPOSED WATER METER, CONTRACTOR TO COORDINATE WITH THE APPROPRIATE
UTILITY PROVIDER.
FIRE TRUCK TURNOUT.
PROPOSED TRANSFORMER LOCATION, CONTRACTOR TO COORDINATE WITH THE
APPROPRIATE UTILITY PROVIDER. BOLLARDS INSTALLED PER PROVIDER STANDARDS.
REFER TO SHEETS PS1.0 AND ES1.0.
PROPOSED SWITCHGEAR, CONTRACTOR TO COORDINATE WITH THE APPROPRIATE
UTILITY PROVIDER. REFER TO SHEET PS1.0.
PROPOSED GAS METER LOCATION, CONTRACTOR TO COORDINATE WITH THE
APPROPRIATE UTILITY PROVIDER. BOLLARDS INSTALLED PER PROVIDER STANDARDS.
REFER TO SHEETS PS1.0 AND P3.0.
INSTALL U-BAR BIKE RACK(S); SEE DETAIL 5/SD2.1.
23 INSTALL ACCESSIBLE PARKING SIGN WITH 'VAN' PLACARD. SEE DETAIL 8/SD2.1.
TOW AWAY SIGN PER LOCAL CODES.
REFERENCE
TRUE
32 ACCESSIBILITY PATH OF TRAVEL FROM ACCESSIBLE AISLE.
1
2
3
3
3
4
4 5
6
7
8
9
10
10
11
12
12
12
12
13
14
15
16
17
18
19
20
21
22
23
24
28
26
27
27
25
25
30
31
32
33
33
FR
O
N
T
A
G
E
R
O
A
D
HWY 74
24
29
LOT AREA:
THE HUMAN BEAN PARKING REQUIREMENTS
THE PARKING REQUIRED:
180/45 S.F. OF OUTDOOR = 6
624/200 S.F. OF KITCHEN= 2
8 SPACES
PARKING PROVIDED:
ACCESSIBLE PARKING = 1 SPACES
STANDARD PARKING = 7 SPACES
TOTAL PARKING PROVIDED = 8 SPACES
1
1
1
FIR
E
T
R
U
C
K
T
U
R
N
O
U
T
.
1
34
EXISTING FIRE HYDRANTS.34
FIRE HYDRANTS
FREESTANDING SIGN AREA CALCULATIONS
TOTAL SITE FRONTAGE : 307 S.F.
ALLOWABLE AREA 20 S.F. PER 100 F.T. OF
FRONTAGE. NOT EXCEED 60 S.F.
GROUND SIGN PROVIDED:
60 S.F. 6' ABOVE PUBLIC SIDEWALK.
SIGNAGE CALCULATION
1
1
SCREEN WALL PROPOSED. 35
35
1
TRAFFIC LIGHT.36
36
0.36 ACRES
2
THE HUMAN BEAN PARCEL
SITE
LANDSCAPE
BUILDING
ASHPHALT
15,981 S.F. (100%)
3,963 S.F. (25%)
624 S.F. (4 %)
10,399 S.F. (65%)
WALKWAY 905 S.F. (6 %)
PLANNING 1ST CORR. 06.28.221
PLANNING 2ND CORR. 10.31.222
DEVELOPMENT SUMMARY
2
2
2
FLOOR AREA RATIO
THE HUMAN BEAN
FAR = 624 S.F.
15,681.6 S.F.
= 0.03
2
GROSS LOT AREA: 15,681.6 S.F.
NET LOT AREA: 15,681.6 S.F.
MK9-X-DT001a.DWG|8
1 1/2" = 1'-0"TAPERED CONC. CURB
EASE EDGE
#3 CONT.
TAPERED CONC
CURB
1/2" RADIUS
TOP OF PAVING
PROPERTY LINE
1'-6"1"2
SD2.0
MK9-X-DT002a.DWG|8
1 1/2" = 1'-0"CONCRETE CURB AT ASPHALT DRIVE
#3 CONT.
1/2" RADIUS
A.C. PAVING PER PLAN
6"1 1/2"8"6"2 1/2"10
SD2.0
CONC. WALK
PLANTER WHERE
OCCURS
MK9-X-DT003a.DWG|8
1 1/2" = 1'-0"MONOLITHIC CONCRETE CURB & WALK
#3 CONT.
SCORE JOINT
A.C. PAVING PER PLAN
CONC. SIDEWALK
6"1 1/2"8"6"2 1/2"MK9-X-DT004a.DWG|8
1 1/2" = 1'-0"CONC. CURB AT CONCRETE DRIVE
CONC. PAVING PER PLAN
6" TYP
SEE NOTE
1 1/2"8"6"2 1/2"10
SD2.0
#3 CONT.
1/2" RADIUS
10
SD2.0
CONC. WALK
PLANTER WHERE
OCCURS
NOTE: TOP OF CURB 4" AT BACK
OF RAMP
MK9-X-DT006a.DWG|8
1 1/2" = 1'-0"CONC. CURB AND GUTTER
A.C. PAVING PER PLAN
#3 CONT.
1" RADIUS
PLANTER WHERE OCCURS
6"1 3/8"6"1"2'-0"5"10
SD2.0
CONC. WALK
MK9-X-DT007a.DWG|8
N.T.S.CONCRETE CURB & GUTTER AT CURB RAMP
10
SD2.0
% OF SLOPE
NOT TO EXCEED 4.9%
CURB RAMP PER PLAN
NOTE:
FOR ITEMS NOT NOTED
SEE 1
SD2.0
GUTTER PER PLAN
2'-0"
7 3/8"
% OF SLOPE
NOT TO EXCEED 4.9%
MK9-X-DT009a.DWG|1
FULL SCALETYPICAL CONTROL JOINT (SAWCUT)3/4"1/8" - 1/4"
NOTE: JOINT IS TO BE SAWCUT WITHIN
2 HRS. OF CONCRETE POUR.
MK9-X-DT010a.DWG|1
FULL SCALEISOLATION JOINT
1/8" RADIUS IF JOINT
IS TROWELED
SEALANT
CONCRETE PAVING
POLYETHYLENE FOAM ROD
ISOLATION JOINT MATERIAL
WHERE INDICATED3/4"3/8"1/2" MAX.
1/4" THICK, 1/2" MAX.MIN.LINE OF FIXED OBJECT,
WHERE OCCURS
1"6"1 1/2"
10 1/2"
1/2" RADIUS
#3 CONT.
10
SD2.0
CONC. PAVING PER
PLAN
MK9-X-DT014a.DWG|8
1 1/2" = 1'-0"CONCRETE CURB AT DRIVE-THRU ALONG BUILDING8"2 1/2"12"
MK9-X-DT017a.DWG|8
1 1/2" = 1'-0"MONOLITHIC CONCRETE CURB AND PAVING2 1/2"6"1 1/2"6"8"CONC. PAVING
1" RADIUS
PLANTER WHERE
OCCURS
1/2" RADIUS
CONC. WALK
#3 CONT.
10
SD2.0
MK9-X-DT019a.DWG|8
1 1/2" = 1'-0"CONCRETE WHEEL STOP
WHEEL STOP
#3 REBAR
FINISH SURFACE
CONCRETE
6"6"
36"
(WHERE OCCURS)
PLANTER WHERE
OCCURS
MK9-X-DT008a.DWG|2
6" = 1'-0"CONSTRUCTION JOINT
FORMED KEYWAY
NOTE: FORM W/ REMOVABLE
MEMBERS ONLY. NO PERMANENT
METAL, PLASTIC OR WOOD
FORMS ARE PERMITTED.
PREVIOUS SLAB
POUR
MUST CONFORM TO
DIMENSIONS SHOWN1"1/4"1/2"3/4"1/4"
SAWCUT IN CURRENT
POUR
FILL JOINT WITH
SEALANT
CURRENT SLAB POUR
POLYETHYLENE FOAM ROD
PLAN
RAISED TRUNCATED
DOMES AS
REQ'D BY
CODE.
1 1/2" = 1'-0"SURFACE APPLIED DETECTABLE WARNING
SLOPED SURFACE OF CURB RAMP
(LEVEL FOR 3'-0" AT SIDEWALK CONDITIONS)
CURB BEYOND (WHERE
OCCURS) PER PLAN
DRIVE / HAZARD PER
PLAN
SECTION
FASTEN TO
CONCRETE PER
MANUFACTURE
REQUIREMENTS.
DETECTABLE WARNING SHALL CONTRAST VISUALLY
WITH ADJOINING SURFACE, AS REQUIRED BY LOCAL
CODE.
NOTE:
PROVIDE TACTILE WARNING SYSTEM ACROSS SLOPE OF CURB
RAMP AS REQUIRED BY LOCAL CODE.
MK9-X-DT011b.dwg|8 (I.B.C. Version)
V.I.F.
(SEE GRADING PLAN)
7.5% MAX.
7.0% MIN.
MK9-X-DT012b.DWG|48
1/4" = 1'-0"DELIVERY RAMP
VERTICAL
RETAINING CURB
EACH SIDE, TYP.
48"
MIN. CLR.48" MIN. WIDTHPER PLANLANDING
PER PLAN
(5'-0" MIN.)
NOTE:
RAMP LENGTH IS DETERMINED BY RAMP
SLOPE, SEE CIVIL DWGS.
NOTE:
CROSS SLOPES TO BE
1.5% MAX.1.5% MAX.CONC. CURB RAMP, MEDIUM
BROOM FINISH, TYP.
VERTICAL
CURB, TYP.
PAINT EDGE OF SLOPED
RAMP YELLOW
MK9-X-DT015b.DWG|48
1/4" = 1'-0"IN LINE CURB RAMP AT PARKING ACCESS
LANDING
PER PLAN
(5'-0" MIN.)PER PLANV.I.F.
(SEE GRADING PLAN)
V.I.F.
(SEE GRADING PLAN)
PAINT EDGE OF SLOPED
RAMP YELLOW
NOTE:
CROSS SLOPES TO BE
1.5% MAX.
CONC.
WALK
ACCESSIBLE
PARKING SIGN
WHERE OCCURS
CONC.
WALK
SLOPE
7.5% MAX.
7.0% MIN.
CONC. CURB AT
CONCRETE DRIVE
RE: 3/SD2.0
1.5% MAX.VERTICAL
CURB, TYP.6"48" MIN. WIDTHSLOPE
7.5% MAX.
7.0% MIN.
NOTE:
RAMP SLOPE TO BE PROVIDED WITH SURFACE APPLIED
DETECTABLE WARNING, SEE DETAIL 16/SD1.0
MK9-X-DT016b.DWG|48
1/4" = 1'-0"WINGED CURB RAMP
PER PLAN
(5'-0" MIN.)48"MIN. CLR.V.I.F.(SEE GRADINGPLAN)NOTE:
RAMP SLOPE TO BE PROVIDED WITH SURFACE APPLIED
DETECTABLE WARNING, SEE DETAIL 16/SD1.0
NOTE:
CROSS SLOPES TO BE
1.5% MAX.
CONC. WALK
ACCESSIBLE PARKING
SIGN, TYP. (IF
APPLICABLE)48"MIN. CLR.48"
MIN. CL
R.SLOPEPAINT EDGE OF SLOPED
RAMP YELLOW
VERTICAL
CURB, TYP.
CONC. CURB RAMP, MEDIUM
BROOM FINISH, TYP.7.5% MAX.7.0% MIN.48"MIN. CLR.MK9-X-DT042a.DWG|8
1 1/2" = 1'-0"TYPICAL ASPHALT CURB
A.C. CURB
1/2" RADIUS
PLANTER
A.C. PAVING PER PLAN
6"1 1/2"6"MK9-X-DT043a.DWG|8
1 1/2" = 1'-0"TYPICAL THICKENED SLAB DETAIL
1'-0"3" CLR.1'-0"EXT. SURFACE
#4 BAR CONT.6"CONC. SLAB & REINF.
PER PLANPER PLAN
ALL REPORTS, PLANS AND
DOCUMENTS PREPARED BY MARKS
ARCHITECTS SHALL REMAIN THE
PROPERTY OF MARKS ARCHITECTS
AND IS INTENDED FOR USE FOR THIS
SPECIFIC PROJECT ONLY.
marks architects 2022
PLANNING SUBMITTAL 01.14.22
MK10B
ADDRESS:
MK TYPE:
JIB #:
MK10B
5497
ⒸSGOOTAESTRENEWAL DATE
CF FLAI12-30-2023 NRAIRKRBAC-31482
AEI M
ALICENS E D ARCH
I
TECTL
HWY 74 NS
EL TORO CUT OFF,
LAKE ELSINORE CA,
92532
DETAILS
SD2.0
AS NOTED
18
2 431
19
1211
10
17
6
1513
5
9
16
7 8
1/4" = 1'-0"IN-LINE CURB RAMP 48" MIN.WIDTH18
SD2.0
19
SD2.0
7.5% MAX.
7.0% MIN.
60"
MIN. CLR.
1.5% MAX.
ANY DIRECTION
3' @ 18:1
6"6"
4' @ 12:1
4"10
SD2.0
6
SD2.2
10
SD2.0
CONC.
PAVING
SIDEWALK
SECTION A-A
TAPERED
CONCRETE
CURB
A
NOTE:
RAMP SLOPE TO BE PROVIDED WITH SURFACE APPLIED
DETECTABLE WARNING, SEE DETAIL 16/SD1.0
NOTE:
CROSS SLOPES TO BE
1.5% MAX.
14
20
MK9-X-DT029a.DWG|24
1/2" = 1'-0"PREVIEW BOARD PLAN
CONC. DRIVE-
THRU LANE
6" CONC. CURB
CONCRETE MENU
BOARD BASE
3/4" C. TO
PANEL "C" FOR
RECEPTACLE
SPEAKER BOARDU.O.N. PER PLAN6'-3"1'-0"20"-0" TO CENTER OF15
SD2.1
4'-0"
3/4" C. TO ABOVE
OFFICE CLG. CIRCUIT
POS-1
3/4" C. TO SPEAKER
BOARD BY ELEC. CONTR.
FOR ILLUMINATION
1" C. TO ABOVE OFFICE CLG.
FOR CAT 5 CABLE
NOTE:
FOR ADDITIONAL INFORMATION
REFER TO DETAIL 17/SD2.1 AND
19/SD2.1
4" DIA. BARRIER POST SEE
DETAIL 14/SD2.1
EXTERIOR CONC. PER PLAN
ALTERNATE:
EXT. CONC. MAY BE PLACED
OVER POLE FTG.1'-6"MIN.1'-6"
DIA.3"CLR.18" DIA. x 18" DP. FTG., CENTER RAIL
POST IN FTG., TYP.
MK9-X-DT021a.DWG|32
3/8" = 1'-0"FOOTING AT EXTERIOR SCREEN WALL
SCREEN WALL
PER ID4.1.3'-8"6"2'-6"<4"
TYP.
EQ22H / EQ22G
MK9-X-DT026a.DWG|24
1/2" = 1'-0"HEIGHT CLEARANCE POLE SIGN
CONC. DRIVEWAY
CONC. CURB
T.O.C.
FIN. GRADE
1'-10"3'-0" MINIMUM1"SIGN FURNISHED AND
STL. POLE AND HT.
INSTALLED BY SIGN
CONTRACTOR
NOTES:
1.LOCATE HEIGHT CLEARANCE SIGN A MINIMUM OF
8'-0"O.C. FROM PREVIEW BOARD.
NOTE: FOUNDATION DESIGN FOR REFERENCE ONLY. SIGN
VENDOR ENGINEER TO DESIGN FOOTINGS UNDER
SEPARATE PERMIT
MK9-X-DT027a.DWG|24
1/2" = 1'-0"DETECTOR LOOP AT DRIVE-THRU PICK UP WINDOW
AT DRIVE-THRU PICK UP
CENTER DETECTOR LOOP
4'-6"1'-6"PREFAB DETECTOR LOOP
THRU LANE
CONC. CURB
CONC. DRIVE-
WINDOW
1'-3"
REFER TO ELEC.
DWGS. FOR DETECTOR
WIRING
J
REFER TO ELEC. DWGS.
TO HME BASE STATION,
FOR ELECTRICAL RUNS REFER TO SHEET ES1.0.
CONDUIT TO SPEAKER BOARD
NOTE:
FOR ADDITIONAL INFORMATION REFER TO
DETAIL 17/SD2.1 AND 19/SD2.1
MK9-X-DT031b.DWG|8
1 1/2" = 1'-0"LIGHT POLE FOOTING
A EMBED. ANCHOR BOLTSCLR.
A
SECTION 'AA'
F.G. OR PAVING
24" DIA. ROUND
CONC. BASE
PROVIDED BY G.C.
MIN. fc'=4000 PSI
4 - 3/4" DIA.
(A307) ANCHOR
BOLT W/ STD.
HOOK
1" RAD., TYP.
DRY PACK
(1" MIN.) BY
G.C.CLR.SHT. ES1.0
CONDUIT, SEE
3/4" ELEC.
LEVELING NUT
AND WASHER
BASE PLATE
3" x 5" HAND HOLE
GROUND LUG OPP.
HAND HOLE
BASE COVER
LOCKNUT AND LIGHT POLE BASE PLATE
C& FTG.BELOW NATURAL AND FINISH GRADE3"10"2"WASHER
#3 TIES AT 12" O.C.3"
3 - #3 TIES 2 3/4" 10" SQ.(VERIFY)3'-0"5'-0" MINIMUMAND BASE 1'-3" MINIMUMSACK FINISH
PROVIDE SMOOTH
FOR ELECTRICAL RUNS REFER TO SHEET ES1.0
DRAIN, TYP.
SLOPE TO
POST
10" DIA. BOLT CIRCLE
(VERIFY)
AT 1.5" O.C.VERIFY W/ MANUF. SPECS.STEEL LIGHT POLE PER
ELECTRICAL DRAWINGS.
FURNISHED BY OWNER, INSTALLED
BY SIGN CONTRACTOR
NOTE: BASE PLATE, ANCHOR BOLTS, AND
TEMPLATES FURNISHED BY OWNER, INSTALLED BY
G.C.
VERIFY BASE TEMPLATE W/ SPECIFIED SITE LIGHT
POLES, SEE ELECTRICAL DWGS.
GALV. STEEL BASE
PLATE
3" SQ. CONDUIT ENTRY
AREA (VERIFY)
6 - #6(v)
ALL REPORTS, PLANS AND
DOCUMENTS PREPARED BY MARKS
ARCHITECTS SHALL REMAIN THE
PROPERTY OF MARKS ARCHITECTS
AND IS INTENDED FOR USE FOR THIS
SPECIFIC PROJECT ONLY.
marks architects 2022
PLANNING SUBMITTAL 01.14.22
MK10B
ADDRESS:
MK TYPE:
JIB #:
MK10B
5497
ⒸSGOOTAESTRENEWAL DATE
CF FLAI12-30-2023 NRAIRKRBAC-31482
AEI M
ALICENS E D ARCH
I
TECTL
HWY 74 NS
EL TORO CUT OFF,
LAKE ELSINORE CA,
92532
SD2.1
DETAILS
AS NOTED
1
8 9
20
10
13
181617
4
15
19
5
6
MK9-X-DT013a.DWG|64
ACCESSIBLE PARKING SPACES 3/16" = 1'-0"
3'-0" SQUARE SYMBOL
OF ACCESSIBILITY;
NOTE:
LOADING ZONE TO BE 1 1/2% MAX.
CROSS SLOPES OF ACCESSIBLE STALLS AND
PAINT (2) WITH COATS WHITE
BEADED REFLECTIVE PAINT
OVER (2) COATS BLUE
BACKGROUND PAINT
1.
PER SITE PLAN
ACCESSIBLE AISLE: 5'-0"
MIN. FOR REGULAR & 8'-0"
MIN. FOR VAN SPACEPER SITE PLAN45°3'-0"TYP.VERTICAL CURB
4" WIDE PAINTED
BLUE STRIPING,
2 COATS (TYP.)
SEE SITE PLAN
PER PLAN
SEE SITE PLAN
ALIGN, TYP.
EQ.
TYP.
EQ.
TYP.
(VAN ACCESSIBLE)36"46"10"6"6"COMPACTED
SUBGRADE
2 3/8"Ø6"BICYCLE RACK
RE: SPECS
2 3/8" DIA. X 0.154"
WALL STEEL TUBING, POWDER COAT
STANDARD SILVER PER MANUFACTURER
GRADE
LEVEL
DRILL HOLE AND
PROVIDE 1/4" ROD
CONCRETE
PAVING
APEX BICYCLE RACK MODEL #AP2-02-EM 2 3/8" O.D., EMBEDDED MOUNT AS
MANUFACTURED BY SITESCAPES INC. OR WAUSAU TILE MF9015 OR APPROVED
ALTERNATE.
1/2" = 1'-0"BIKE RACK3
MK9-X-DT033a.DWG|24
1/2" = 1'-0"BARRIER POST
FIN. GRADE
CONC. FOOTING
RADIUSED SMOOTH
INSTALLED BY
GEN. CONTR.1" CONC. CAP3'-0"3'-0"1'-6"6"DIA.
REFLECTIVE RED TAPE 3"3" WIDE BAND OF
CONC. CAP
4" DIA. GALV. PIPE FILLED
W/ CONCRETE
PAINT, COLOR TO BE SHERWIN
WILLIAMS SW 7020 "BLACK FOX"
MK9-X-DT025b.DWG|1
NO SCALECOMING SOONISH SIGN
NOTE:
GENERAL CONTRACTOR TO FURNISH AND INSTALL
SIGN BOARD COMPLETE W/ 4x4 REDWOOD POSTS.
SIGN BOARD TO BE MINIMUM 3/4" EXTERIOR GRADE
PLYWOOD. PAINT ALL EDGES AND FACES:
BENJAMIN MOORE #071-967 "WHITE"
ATTACH OWNER PROVIDED BANNER.
8'-0"4'-0"3'-0"TMSOONISH
OPENING
1"FIN. GRADE
TOP OF CURB
MENU BOARD AND POSTS FURNISHED
AND INSTALLED BY SIGN CONTRACTOR
7'-0"
BASE COVER 4'-0 3/4"1'-8"1'-8"
3/4" C. TO PANEL "C"
FOR RECEPTACLE 4'-0" MIN.DIA.
16 AA
SD2.1
MK9-X-DT034a.DWG|24
1/2" = 1'-0"PREVIEW BOARD ELEVATION
3/4" C. TO ABOVE
OFFICE CLG. CIRCUIT
POS-1
1" C. TO ABOVE OFFICE
CLG. FOR CAT 5 CABLE
3/4" C. TO SPEAKER BOARD.
EXTEND ALL CONDUIT TO
ABOVE CONC. BASE, BY ELEC.
CONTR. SEE DETAIL 17/SD2.1.
NOTE:
FOR ADDITIONAL
INFORMATION REFER TO
DETAIL 17/SD2.1 AND
19/SD2.1
20
SD2.0
NOTE: FOUNDATION
DESIGN FOR REFERENCE
ONLY. SIGN VENDOR
ENGINEER TO DESIGN
FOOTINGS UNDER
SEPARATE PERMIT
MK10-X-DT032a.DWG|1
NO SCALESPEAKER BOARD CONDUIT DETAIL±2'-6"3/4" C. TO PREVIEW BD.
3/4" C. TO CIRCUIT A-2
3/4" C. TO ABOVE OFFICE
CLG., CIRCUIT POS-1
1" C. TO ABOVE OFFICE
CLG. FOR 'CAT 5' CABLE
SPEAKER BOARD ENCLOSURE
PROVIDED AND INSTALLED
BY SIGN CONTRACTOR
3/4" C. TO PICK UP WINDOW
FOR COMMUNICATION CABLE
3/4" C. TO
DETECTOR LOOP
FOR ELECTRICAL RUNS REFER TO SHEET ES1.0
STUB CONDUITS 1" ABOVE
LOWER EDGE OF HAND
HOLE. PROVIDE ELEC.
GROUNDING
3 1/2"x 6" HAND HOLE
WITH COVER
(5) - 3/4" & (1) - 1" CONDUITS
UP WITHIN POLE
CONTINUE WIRING UP POLE FOR
CANOPY LIGHTING. COORDINATE
REQUIREMENTS WITH CANOPY SUPPLIER
GROUND MOUNTED J-BOX
(3) 1" C. TO ABOVE OFFICE CONC. DRIVEWAY
LOOP SUPPORT
CONC. CURB
PREFAB DETECTOR
LOOP FURNISHED BY
OWNER & INSTALLED
BY CONTRACTOR
T.O.C.
FIN. GRADE
8'-0"SIGN VENDOR ENGINEER MAY MODIFYDEPTH PER SITE SPECIFIC CONDITIONSCOVER
2'-0" MIN
BASE
2" MAX.1"18
SD2.1
FOR ADDITIONAL INFORMATION REFER
TO DETAIL 17/SD2.1
(4)-5/8"Ø x 36" EMBED MIN. HEADED
ANCHOR RODS (4" PROJ.), FURNISHED AND
INSTALLED BY GEN. CONTR.. SEE DETAIL
13/SD2.1 FOR ANCHOR ROD LAYOUT
FOR ELECTRICAL RUNS REFER TO SHEET ES1.0MK9-X-DT035b.DWG|24
1/2" = 1'-0"SPEAKER BOARD SECTION 9'-6"6"7'-0"
PREFABRICATED WEATHER CANOPY PROVIDED AND
INSTALLED BY SIGN CONTRACTOR
3" CLR.
TYP.
#4 TIES @ 4" O.C. TOP
32", REMAINDER @ 12"
0.C.
(12)-#4V
DESIGNER'S NOTE: FOUNDATION BASED UPON 140 MPH
EXPOSURE C AND 30 PSF GROUND SNOW LOADING.
CONCRETE STRENGTH TO BE 2500 PSI MIN. REDESIGN
FOUNDATION AS REQ'D BASED UPON SITE SPECIFIC
LOADING REQUIREMENTS
NOTE:
CONCRETE BASE TO HAVE 1" RADIUS EDGES AND BE
SLOPED TO DRAIN.
NOTE: FOUNDATION DESIGN FOR REFERENCE ONLY. SIGN
VENDOR ENGINEER TO DESIGN FOOTINGS UNDER
SEPARATE PERMIT
3 1/2" DIA. OPENING
BASE PLATE
9" SQUARE X 1/2" THICK9" O.C.FURNISHED AND
INSTALLED BY SIGN
CONTRACTOR
1 1/2" x 5/8" HOLE
TYPICAL OF 4
5"Ø STEEL PIPE
NOTE:COORDINATE ANCHOR BOLT
LAYOUT WITH SIGN CONTRACTOR
PRIOR TO INSTALLATION
MK9-X-DT028b.DWG|4
1 1/2" = 1'-0"BOLTING TEMPLATE AT SPEAKER
AND PREVIEW BOARDS 1'-3" SQUARE X 3/4" THICK6"
5/8" HOLE
TYPICAL OF 4
SPEAKERPREVIEW BOARDS
MK9A-X-DT01.DWG|32
3/8" = 1'-0"STANDARD OUTDOOR SEATING EXAMPLE
SCREEN WALL PER SITE PLAN.
FOR ADDITIONAL INFORMATION, SEE 3/SD2.1.
PATIO UMBRELLAS WITH FREE
STANDING BASE
4'-0" MIN.TO WALL OROTHER OBSTRUCTION3'-8"
MIN., TYP.
3'-8"
MIN., TYP.3'-0"MIN. TO SCREENWALLOF-PT1
OF-TU1
NOTES:
·PATIO FURNITURE LAYOUT SHALL COMPLY WITH
ACCESSIBILITY AND EGRESS PATH OF TRAVEL
REQUIREMENTS
·DESIGN PATIO LAYOUT WITH DESIRED TABLE SIZES
AS LISTED ON SHEET ID4.1
OF-PT2 OF-PT3
MK10-X-DT030a.DWG|24
1/2" = 1'-0"SPEAKER BOARD PLAN
4'-0"
1'-0"
BOARD
TO PREVIEW
4'-6"1'-6"PREFAB DETECTOR LOOP
THRU LANE
6" CONC. CURB
CONC. DRIVE-
19
SD2.1
1'-3"
4" DIA. BARRIER POST
SEE DETAIL 4/SD2.1
REFER TO DETAIL 17/SD2.1 FOR
DESCRIPTION.
NOTE:
FOR ADDITIONAL INFORMATION REFER TO
DETAIL 17/SD2.1 AND 19/SD2.1
CENTER DETECTOR
LOOP ON SPEAKER
BOARD
NO SCALEMETAL PARKING SIGNS
1 3/4" R. TYP.60"ABOVE FINISH GRADE24"18"
ADA SIGN PROVIDED BY GENERAL
CONTRACTOR OF-EQ21A & OF-EQ21B
SIGNS ARE OWNER FURNISHED.
POLES ARE PROVIDED BY GENERAL
CONTRACTOR. ALL SIGNS & POLES
ARE INSTALLED BY THE GENERAL
CONTRACTOR.
NOTES:
1.SEE SHT. SD1.0 FOR LOCATION.
2.SET 1 3/4" SQ. GALV. STL. POST INTO 1' SQ. x 2' DEEP
CONCRETE FOOTING.
3.WHENEVER POSSIBLE SIGNS TO BE LOCATED ON THE
BUILDING DIRECTLY IN FRONT OF PARKING STALLS AT 5'-0"
FROM C.L. TO FINISH GRADE OR MOUNTED ON POLES IN
LANDSCAPE AREA AT +80" FROM BOTTOM OF SIGN TO FINISH
GRADE.
4.SEE ID SHEETS FOR ONLINE ORDER PICK-UP SIGN (OF-EQ21A)
& DRIVE-THRU WAITING PARKING (OF-EQ21B).
14281432∆=13° 14' 57" R = 686.71' L=158.00'NOPARKINGVAN282725
1.8%
MAX
6.0'26
28
RIDGE27
BIORETENTION BASIN#2
26.80TOP, 26.30FG
EX STREETCENTERLINE
MATCH
(32.00FS)
MATCH
(25.35FS)
25.48TC
24.81FL
25.56FS
28.32TC
27.82FS
27.30TC
26.80FS
26.98TC
26.48FL-LP
29.22TC
28.72FS 29.22TC
28.72FS
28.61FS
32.09TC
31.42FL
28.50FS27.65TC
27.15LP
26.80FG 26.80FG
27.30TC
26.80FL-CC
28.53TC
28.03FS
28.23TC
27.73FS
28.32
FS-GB
28.91TC
28.41FL
32.21FS
25.85FG
25.15TG
28.70FS
25.70TC
25.03FL
25.78FS
25.36FG
28.46TC
27.96FS
MATCH
(31.00FS)
26.80TG
28.23
FS-GB
28.40FS
PROP.
PROPERTY LINE
EX PROPERTY
LINE
PROP. 0.4' DEDICATION TO
THE CITY OF LAKE ELSINORE
0.4'28.34TC
27.84FS
ADA PATH
OF TRAVEL1416
1416 14261424
1422
1422
1418
1416141814281426142414221414141214241422141414121408140614041402141814101420
1420
1420143014001420
N14°21'
3
4
"
E
3
8
7
.
9
4'
N26°04'00"E 229.0
0
'N64°20'02"W 124.88'N58°57'31"W (R)
∆=07° 12' 32" R = 3266.60' L=411.00'
∆=11° 23'
4
5
"
R
=
6
6
6
.
7
1'
L
=
1
3
2
.
6
1'
N64°14'50"W (R)
∆=07° 12' 59" R = 3267.00' L=4
1
1
.
4
8
'
N26°04'00"E 22
7
.
0
7
'
26
24
23
24
23
22
21
2019181716151413
25
12
1110
22 272625
25 262528
9
8
765
4
32
27
24
239.0'
TYP.26.0
'
27
50.21'
FRONT
A
G
E
R
O
A
D
HIGHWAY 74
EXISTING EDGE
OF PAVEMENT
EXISTING EDGEOF PAVEMENT
PROPOSED BUS
STOP LOCATION RIDGERIDGE
END OF PROP. AC
IMPROVEMENTS
EX DIRT PATHTO REMAIN 55.0' TYP.6.5'67.0'10.5'50.0'
EXCEPTION 5 -
EASEMENT FORPUBLIC UTILITIES.
PERFORATED CMP W/ ORIFICE
OUTLET FOR FLOW CONTROL
EX STREET
CENTERLINE
SIGHT DIST.
"POINT A"
SIGHT DIST."POINT C"
SIGHT LINE FROM
"POINT A TO C"
RIGHT IN
RIGHT OUT
FRONTAGE ROAD TO BEMAINTAINED BY CITY OF
LAKE ELSINORE
FRONTAGE ROAD TO
BE MAINTAINED BY CITY
OF LAKE ELSINORE
27
INSTALL "NO LEFT TURN"
SIGN PER MUTCD R3-1
MATCH
(28.00FS)
MATCH
(24.00FS)MATCH
(22.00FS)
26.38TC
25.71FL
22.80TC
22.13FL
MATCH
(21.00FS)
21.23TC
20.56FL
MATCH
(24.00FS)
MATCH
(22.00FS)
MATCH
(20.00FS)
MATCH
(18.00FS)
MATCH
(16.00FS)
21.85TC
21.18FL
20.31TC
19.64FL
18.47TC
17.80FL
16.47TC
15.80FL
23.08TC
22.58FS-TG
22.09
FS
26.33TC
25.83FS
25.77TC
25.27FS
24.25TC
23.75FS
26.10TC
25.60FL
25.29TC
24.79FS
23.88TC
23.21FL
23.96
TC-FS
24.71FS
28.36TC
27.86FS
27.84TC
27.34FS
26.36TC
25.86FS
26.17
FS-GB
26.18
FS-0"CF
MATCH
(26.00FS)
26.53TC
26.03FS
MATCH
(12.00FS)
12.47TC
11.80FL
MATCH
(8.00FS)
8.35TC
7.68FL
MATCH
(4.00FS)
MATCH
(2.00FS)
26.69TC
26.19FS
27.04TC
26.54FL
18.55FS
21.93FS
MATCH
(18.00FS)
14.47TC
13.80FL
MATCH
(14.00FS)
21.47FG
24.51FS
24.13FS
24.04FS
12.67TC
12.00FL
12.80FS
22.92FS
21.34FS
22.67TC
22.17FL-CC
MATCH
(19.00FS)
MATCH
(16.00FS)
25.50TC
25.00FS
25.50TC
25.00FL
2.22FS
26.62FG
12.55FS
24.50TC
24.00FL
PROP. 0.4' DEDICATION TO
THE CITY OF LAKE ELSINORE
MATCH
(13.00FS)
26.00TG
16.55FS
16.36FS
MATCH
(14.00FS)
MATCH
(10.00FS)
MATCH
(2.00FS)
MATCH
(4.00FS)
MATCH
(6.00FS)
MATCH
(8.00FS)
MATCH
(11.41FS)
28.25FG 29.27FS 29.37FS
14.55FS
10.47TC
9.80FL
10.55FS
MATCH
(9.00FS)
9.32TC
8.64FL
9.40FS
8.43FS
32.29TC
29.62FL
30.38FS
6.45TC
5.78FL
6.53FS
4.21FS
20.39FS
29.30FS
15.77TC
15.10FL
14.08TC
13.41FL
14.32FG
16.01FG
17.73TC
17.06FL
17.97FG
13.08TC
12.41FL
13.20FS
20.13TC
19.46FL
20.37FG
23.80TC
23.13FL
27.48TC
26.81FL
24.04FG 26.50FS
23.92FS
22.95TG
20.76TC
20.09FL
4.13TC
3.63FL
2.14TC
1.64FL
MATCH
(30.00FS)
MATCH
(00.23FS)
24.61FS
28.46FS
ADA PATH
OF TRAVEL
20.84FS
28.31
FL-HP
27.76
FL-HP
MATCH
(5.00FS)
MATCH
(6.00FS)
MATCH
(7.00FS)
MATCH
(17.00FS)
MATCH
(20.00FS)
MATCH
(23.00FS)
MATCH
(25.00FS)
MATCH
(27.00FS)
MATCH
(29.00FS)
22.32TC
21.65FL
24.91FS
24.83TC
24.33FS18.0' TYP.26.0'16.0' TYP.26.33
FS-GB
26.26TC
25.76FL-CC
PROP.PROPERTY LINE
EX PROPERTYLINE
PROP. SIDEWALKCURB DRAIN
Q10=0.43cfs
Q100=0.73cfsEND OF PROP. GUTTER
EX SQ10=2.29cfs
SQ100=4.11cfsPROP SQ10=3.57cfs
SQ100=5.97cfs
PROP. SIDEWALK
UNDERDRAINQ10=2.63cfs
Q100=4.31cfs
4.5'22.0
' TYP.
EX STREETCENTERLINE
EX PROPERTYLINE TO REMAIN
EXISTING PROPERTY
LINE TO REMAIN
ADA PATH
OF TRAVEL
29.24TC
28.57FL24.43'EX STREET
CENTERLINE
EX STREETCENTERLINE
EX PROPERTY LINE
TO BE REMOVED
27.31TC
26.81FS
27.39
FS-GB
27.48
FS-GB
27.97TC
27.47FS
27.99TC
27.66FS
PROP. 0.4' DEDICATION TO
THE CITY OF LAKE ELSINORE
0.4'ADA PATH
OF TRAVEL
CG-01
CONCEPTUAL GRADING
EXISTING CONCRETE
PROPOSED ASPHALT
PROPOSED CONCRETE
LANDSCAPING
PROPERTY LINE
CENTERLINE
GRADING LIMITS
SIGHT DISTANCE
PROPOSED SEWER LINE
PROPOSED STORM LINE
PROPOSED WATER LINE
PROPOSED IRRIGATION LINE
PROPOSED CONTOUR
EXISTING CONTOUR
EXISTING SEWER LINE
EXISTING WATER LINE
LEGEND
PROJECT SITE
VICINITY MAP
CONCEPTUAL GRADING
CUT: 601 CY
FILL: 3947 CY
NET FILL: 3346 CY
CIVIL ENGINEER
COMMERCIAL DEVELOPMENT RESOURCES
695 TOWN CENTER DRIVE, #110
COSTA MESA, CA 92626
P: 949.610.8997
ARCHITECT
MARKS ARCHITECTS
2643 4TH AVE.
SAN DIEGO, CA 92103
P: 619.702.9448
SOILS ENGINEER
CW SOILS
MURRIETA, CA 92562
P: 951.304.3935
SURVEYOR
COMMERCIAL DEVELOPMENT RESOURCES
695 TOWN CENTER DRIVE, #110
COSTA MESA, CA 92626
NUMBER DATE
REVISIONS
APP'V'D BENCHMARK:
HL
MLCHECKED BY:
DRAWN BY:
DATE:
PLANS PREPARED BY:
AARON M. ALBERTSON DATE
R.C.E. 65513, EXP. 09/30/23
01/11/23
01/11/2023
EL TORO DEVELOPMENT
EL TORO CUT OFF
LAKE ELSINORE, CA 92532
SHEET
OF
BASIS OF BEARINGS:EXIST. APN:
THE BASIS OF BEARINGS FOR THIS SURVEY IS THAT
PORTION OF THE CENTERLINE OF STATE HIGHWAY 74,
AS SHOWN ON SHEET 8 OF 15 ON ROS 123/94-108,
I.E. N 26°04'00" E.
THE BENCHMARK FOR THIS SURVEY IS USGS
BENCHMARK DESIGNATION "D 307," LOCATED AT THE
WESTERLY CORNER OF EL TORO CUTTOFF AND THE
NORTHERLY FRONTAGE ROAD.
ELEVATION = 1425.75 FEET (NAVD 88)
347-130-033
347-130-034
347-130035
07MATCHLINESUNBLAZE RD74
74
RO
S
E
T
T
A
C
A
N
Y
O
N
D
R
N. FRONTAGE RD N. FRONTAGE RDEL TOROCUT OFF
RD
LEGAL DESCRIPTION
SITE ADDRESS
HWY 74 NS
EL TORO CUT OFF
LAKE ELSINORE, CA
92532
APN #: 347-130-033 & 347-130-034
OWNER
BESHAY FOODS
41760 IVY ST. #201
MURRIETA, CA 92562
CONTACT: DAVID BESHAY
P: 951.816.0189
FLOOD ZONE
SIGHT DISTANCE NOTE
BENCHMARK
BASIS OF BEARINGS
* RESTRICTED USE AREAS SHOWN PER 25 MPH & 55
MPH COUNTY OF RIVERSIDE STANDARD NO. 821.
TITLE REPORT INFORMATION
AN EASEMENT FOR PUBLIC UTILITIES AND INCIDENTAL
PURPOSES, RECORDED NOVEMBER 18, 2010 AS
INSTRUMENT NO. 2010-0556115 OF OFFICIAL RECORDS.
(XXX.XX)EXISTING ELEVATION
APN ASSESSOR'S PARCEL NO.
℄CENTER LINE
EX EXISTING
FG FINISH GROUND
FL FLOWLINE
FS FINISH SURFACE
GB GRADE BREAK
INV INVERT
LF LINEAR FEET
LS LANDSCAPE AREA
PL PROPERTY LINE
ROW RIGHT OF WAY
SD STORM DRAIN
TC TOP OF CURB
TG TOP OF GRATE
TY TYPICAL
ABBREVIATIONS:
ZONE X (UNSHADED), AREA DETERMINED BE
OUTSIDE THE 0.2% ANNUAL CHANCE
FLOODPLAIN, PER FEMA FIRM PANEL
06065C2029G EFFECTIVE AUGUST 28, 2028.
THE BASIS OF BEARINGS FOR THIS SURVEY
IS THAT PORTION OF THE CENTERLINE OF
STATE HIGHWAY 74, AS SHOWN ON SHEET
8 OF 15 ON ROS 123/94-108, N 26°04'00" E.
THE BENCHMARK FOR THIS SURVEY IS
USGS BENCHMARK DESIGNATION "D 307,"
LOCATED AT THE WESTERLY CORNER OF
EL TORO CUTTOFF AND THE NORTHERLY
FRONTAGE ROAD.
ELEVATION = 1425.75 FEET (NAVD 88)
REAL PROPERTY IN THE CITY OF LAKE ELSINORE, COUNTY OF RIVERSIDE, STATE OF
CALIFORNIA, DESCRIBED AS FOLLOWS:
PARCEL 3 OF PARCEL MAP NO. 19924, AS SHOWN BY PARCEL MAP ON FILE IN BOOK
122, PAGES 44 THROUGH 48, INCLUSIVE, OF PARCEL MAPS, RECORDS OF RIVERSIDE
COUNTY, CALIFORNIA.
EXCEPTING THEREFROM THAT PORTION OF SAID LAND REFERRED TO IN EXHIBIT J-1,
DESCRIBED IN DOCUMENT ENTITLED "AGREEMENT REGARDING IRREVOCABLE
OFFER OF DEDICATION" RECORDED JUNE 20, 2003 AS INSTRUMENT NO. 2003-454141
OF OFFICIAL RECORDS.
ALSO EXCEPTING THEREFROM THAT PORTION OF SAID LAND LYING WITHIN TRACT
NO. 25479, AS SHOWN ON THE MAP RECORDED IN BOOK 367, PAGES 93 THROUGH
113, INCLUSIVE, OF MAPS, RECORDS OF RIVERSIDE COUNTY.
ALSO EXCEPTING THEREFROM ALL SUBSURFACE WATER RIGHTS AS DEDICATED TO
THE CITY OF LAKE ELSINORE, OR ITS ASSIGNEES, AS DEDICATED AND ACCEPTED ON
THE OWNERS CERTIFICATE OF SAID PARCEL MAP.
NUMBER DATE
REVISIONS
APP'V'D BENCHMARK:
HL
MLCHECKED BY:
DRAWN BY:
DATE:
PLANS PREPARED BY:
AARON M. ALBERTSON DATE
R.C.E. 65513, EXP. 09/30/23
01/11/23
01/11/2023
EL TORO DEVELOPMENT
EL TORO CUT OFF
LAKE ELSINORE, CA 92532
SHEET
OF
BASIS OF BEARINGS:EXIST. APN:
THE BASIS OF BEARINGS FOR THIS SURVEY IS THAT
PORTION OF THE CENTERLINE OF STATE HIGHWAY 74,
AS SHOWN ON SHEET 8 OF 15 ON ROS 123/94-108,
I.E. N 26°04'00" E.
THE BENCHMARK FOR THIS SURVEY IS USGS
BENCHMARK DESIGNATION "D 307," LOCATED AT THE
WESTERLY CORNER OF EL TORO CUTTOFF AND THE
NORTHERLY FRONTAGE ROAD.
ELEVATION = 1425.75 FEET (NAVD 88)
347-130-033
347-130-034
347-130035
07
NUMBER DATE
REVISIONS
APP'V'D BENCHMARK:
HL
MLCHECKED BY:
DRAWN BY:
DATE:
PLANS PREPARED BY:
AARON M. ALBERTSON DATE
R.C.E. 65513, EXP. 09/30/23
01/11/23
01/11/2023
EL TORO DEVELOPMENT
EL TORO CUT OFF
LAKE ELSINORE, CA 92532
SHEET
OF
BASIS OF BEARINGS:EXIST. APN:
THE BASIS OF BEARINGS FOR THIS SURVEY IS THAT
PORTION OF THE CENTERLINE OF STATE HIGHWAY 74,
AS SHOWN ON SHEET 8 OF 15 ON ROS 123/94-108,
I.E. N 26°04'00" E.
THE BENCHMARK FOR THIS SURVEY IS USGS
BENCHMARK DESIGNATION "D 307," LOCATED AT THE
WESTERLY CORNER OF EL TORO CUTTOFF AND THE
NORTHERLY FRONTAGE ROAD.
ELEVATION = 1425.75 FEET (NAVD 88)
347-130-033
347-130-034
347-130035
07
5. AN EASEMENT FOR PUBLIC UTILITIES AND INCIDENTAL PURPOSES,
RECORDED NOVEMBER 18, 2010 AS INSTRUMENT IN NO. 2010-0556115 OF
OFFICIAL RECORDS.
IN FAVOR OF:SOUTHERN CALIFORNIA
EDISON COMPANY, A
CORPORATION, THEIR
SUCCESSORS
AND ASSIGNS
AFFECTS:AS DESCRIBED THEREIN
6. RIGHTS OF THE PUBLIC IN AND TO THAT PORTION OF THE LAND LYING
WITHIN ANY ROAD, STREET, ALLEY OR HIGHWAY.
7. WATER RIGHTS, CLAIMS FOR TITLE TO WATER, WHETHER OR NOT SHOWN BY
THE PUBLIC RECORDS.
8. RIGHTS OF PARTIES IN POSSESSION.
EXISTING EASEMENTS:
01
SD SD
W
IW
SS
W
XX
MATCHLINEMATCHLINEXX
1430N64°20'02"W 124.88'N58°57'31"W (R)
N64°14'50"W (R)272625
27 RIDGERIDGE
SIGHT DIST.
"POINT A"
26.10TC
25.60FL
25.29TC
24.79FS
24.71FS
27.84TC
27.34FS
27.04TC
26.54FL
26.00TG
29.37FS
32.29TC
29.62FL
30.38FS
MATCH
(30.00FS)
28.46FS
27.76
FL-HP
26.33
FS-GB
EX PROPERTY LINETO BE REMOVED
27.31TC
26.81FS
27.39
FS-GB
27.48
FS-GB
27.97TC
27.47FS
27.99TC
27.66FS
1432
14281428
14361434143214381426
14
2
6
14
2
4
1428
1434 14321434
14421444
1446
1448
1446
1444
1442
1436
14381430
1440
145014401430
1430 14301440
1432
N09°37'2
6
"
W33.67'N86°18'05"E31.75'∆=04° 12' 47" R = 1034.25' L=76.05'∆=13° 14' 57" R = 686.71' L=158.00'N81°39
'22
"E31.97
'
∆=05° 04' 40"
R
=
3
2
6
6
.
6
0
'
L
=
2
8
9
.
5
0
'
∆=
0
5
°
4
2
'
4
5
"
R =
6
8
6
.
7
1
'
L=6
8
.
4
7
'N83°29
'46
"E
62
.58
'
N5
8
°
0
9
'
3
2
"
E
1
1
4
.
2
1
'
N01°
2
3'
3
6"
E
30.48'
∆=96° 28' 50"
R = 46.40'
L=78.13'∆=03° 31' 39" R = 934.25' L=57.52'NOPARKINGVANS58
°
0
4
'
5
9
"
W
1
2
0
.
3
2
'
∆=05° 03' 43" R = 32
6
7
.
0
0
'
L
=
2
8
8
.
6
3
'NOPARKINGPROP. BUILDING
FF=28.72
PAD=28.22
2828
2725 26
29 30
31
32
33 34
1.8%
MAX
12.00'36.0'6.0'8.0'4.5'3.5'6.5'5.5'EL TORO CUT OFF RDEX EDGE OFPAVEMENT
PROB. BUILDING
FF=38.00
PAD=37.59
EX EDGE OF
PAVEMENT
46
45
44
43
42
41
40
39
38
38
39
40
4243444536353737
37
3735
34
32 313233
3430
36 3731
24.
0
'RIDGE1.8%
MAX 9.0'
TYP.24.0'
T
Y
P.18.0' TYP.12.0'SIGHT DIST.
"POINT A"
SIGHT DIST."POINT C"
3.0'
SIG
H
T
D
I
S
T
A
N
C
E
1
7
5
'
T
O
T
A
L
36.0'
FRONT
A
G
E
R
O
A
D
HIGHWAY 74
PROP. PARTIAL STREET IMPROVEMENTS
ON NORTH SIDE OF FRONTAGE ROAD TO
ACCOMMODATE FIRE TRUCK HAMMER
HEAD TURN MANEUVER/REQUIREMENTS
PROP. STREET CLOSURE
BARRIER AND SIGNAGE
55.0' TYP.26
28
RIDGE27
26
27RIDGE
2.0'2.0'12.0'10.0'PERFORATED CMP
W/ ORIFICE OUTLET
FOR FLOW CONTROL
BIORETENTION BASIN#1
25.65TOP, 25.15FG
BIORETENTION BASIN#2
26.80TOP, 26.30FG
41EXISTING EDGE
OF PAVEMENT
EXISTING EDGEOF PAVEMENT
EXISTING EDGE
OF PAVEMENT
HAMMER HEAD
TEMPLATE24.0'SIGHT LINE FROM"POINT A TO C"
SIGHT LINE FROM
"POINT A TO C"
SIGHT DIST."POINT C"
SIGHT LINE FROM
"POINT A TO C"
EX STREETCENTERLINE
EX STREET
CENTERLINE
FRONTAGE ROAD TO BE MAINTAINEDBY CITY OF LAKE ELSINORE
292828
33.95TC
33.28FL
MATCH
(33.00FS)
MATCH
(34.00FS)
MATCH
(32.00FS)
33.01TC
32.34FL
MATCH
(27.00FS)
MATCH
(26.00FS)MATCH
(25.35FS)
26.36TC
25.68FL25.48TC
24.81FL
25.56FS
28.32TC
27.82FS
28.23TC
27.73FL 28.67TC
28.17FS
28.21TC
27.71FS
29.13TC
28.63FS-HP
27.30TC
26.80FS
28.69TC
28.19FL
27.80TC
27.30FL
26.98TC
26.48FL-LP
29.22TC
28.72FS 29.22TC
28.72FS
28.61FS
32.09TC
31.42FL
28.50FS27.65TC
27.15LP
26.80FG 26.80FG
27.30TC
26.80FL-CC
28.53TC
28.03FS
28.23TC
27.73FS
28.32
FS-GB
28.47FS
28.91TC
28.41FL
32.21FS
MATCH
(32.00FS)
MATCH
(34.00FS)
27.23FS
26.44FS
33.86TC
33.19FL
MATCH
(46.00FS)
MATCH
(44.00FS)
MATCH
(42.00FS)
MATCH
(40.00FS)
MATCH
(38.00FS)
40.04TC
39.38FL
42.04TC
41.37FL
44.02TC
43.35FL
46.07TC
45.40FL
46.17FS
44.10FS
42.12FS
40.14FS
MATCH
(42.00FS)
MATCH
(32.00FS)
32.35TC
31.68FL
34.35TC
33.68FL
MATCH
(32.00FS)
46.28FG
44.21FG
42.23FG
40.25FG
34.41FS
32.41FS
30.49FS
32.48FG
30.56FG
34.47FG
MATCH
(39.00FS)
39.06TC
38.39FL
39.06FS
39.17FG
MATCH
(34.00FS)
MATCH
(36.00FS)
32.18TC
31.51FL
34.18TC
33.51FL
32.26FS
34.26FS
34.41FG
32.41FG
46.04FG
37.66TC
37.16FS
MATCH
(32.87FS)
MATCH
(37.13FS)
MATCH
(32.56FS)
36.87TC
36.20FL
38.01TC
37.34FL
36.85
TC-FL
36.77
TC-FL
37.44FS
37.52FS
37.52FS
37.59TC
37.09FL
37.64TC
37.14FS 37.98FS
36.36TC
35.86FS
34.41FS
34.92FS
34.49FS
35.01FS
35.66TC
35.16FL
35.16TC
34.66FS
37.69FS
37.04TC
36.64FL
37.41TW
36.91TC
36.41FL
37.78TC
37.28FS
37.58TC
37.08FS
36.16TW
35.63TC
36.13FL
35.52TC
35.02FS
34.04TC
33.54FL-CC
37.15TW
35.56FS
33.11FS
37.55TC
37.05FS
37.69TC
37.19FS
38.00TC
37.50FS
38.00TC
37.50FS
37.53FS
37.47TC
36.97FS
37.76TC
37.26FL
MATCH
(30.00FS)
MATCH
(34.00FS)
37.60TC
37.10FS
MATCH
(44.00FS)
MATCH
(46.00FS)
MATCH
(38.46FS)
34.30
TC-FL
34.33
TC-FL
35.00FS
34.97FS
29.03FS
29.11FS
MATCH
(35.80FS)
45.63TW
37.93FG
45.13FG
40.97FG 36.66TC
36.16FS
37.03TC
36.53FS
42.73TW
38.96FG
46.31TW
37.62FG
MATCH
(36.00FS)
MATCH
(36.50FG)
37.57TW
37.07FG
38.00TC
37.50FS
37.35TC
36.85FL
37.89TW
37.39FG
MATCH
(30.00FS)
MATCH
(34.00FS)
41.61FG
42.11TW
40.07FG
MATCH
(35.00FS)
MATCH
(35.00FS)
MATCH
(33.00FS)
MATCH
(33.00FS)
MATCH
(45.00FS)
MATCH
(43.00FS)
30.71
TC-FL
30.64
TC-FL
31.38FS
31.31FS
45.81FG
31.38FS
29.79TC
29.12FL
29.87FS
26.51FG25.85FG
25.15TG
27.35FG
28.70FS
28.70FS
28.50TC
28.00FS
29.19FS
29.11FS
34.88FS
35.08FS35.00FG
35.10FG
25.70TC
25.03FL
25.78FS
34.07FS
29.64TC
28.97FL
29.90TC
29.23FL
28.50
FL-HP
25.36FG
28.21TC
27.54FL
31.90TC
31.23FL31.98FS
33.94FS
34.09FG
32.90TC
32.23FL
32.98FS
33.13FG
32.13FG
28.36
TC-FL
28.44
TC-FL
29.25FG
34.80TC
34.13FL
35.70TC
35.03FL
29.98FS
27.14TC
26.47FL
37.18TC
36.68FS
37.41TC
36.91FS
37.61FS
37.64
TC-FS
37.76TC
37.25FS
44.71TW
37.89FG
30.43TC
29.76FL
PROP. STOP SIGN PER CITY
OF LAKE ELSINORE STD 406A
PROP. "FRONTAGE ROAD"
STREET NAME SIGN PER CITYOF LAKE ELSINORE STD 400B
31.46FS
MATCH
(30.00FS)
PROPOSED "EL TORO CUT OFF"
STREET NAME SIGN PER CITY OF
LAKE ELSINORE STD 400B
MATCH
(28.00FS)
28.46TC
27.96FS
MATCH
(29.00FS)
MATCH
(31.00FS)
37.71TC
37.21FS
37.59FS
37.52TC
37.02FL
37.71
TC-FS
ADA PATH
OF TRAVEL
MATCH
(35.00FS)
33
26.80TG
FRONTAGE ROAD TO BE
MAINTAINED BY CITY OF
LAKE ELSINORE
22.0'MATCH
(31.00FS)
MATCH
(30.00FS)
HAMMER HEAD
TEMPLATE
37.03
FS-0"CF37.60
FS-0"CF
36.48TC
35.98FL
36.46TC
35.96FL
35.20TC
34.70FS
34.71FS
35.70TC
35.20FL
35.77
FS-FG
35.48TC
34.98FL 34.09FG
34.34FS
34.42FSGB18.0' TYP.4.5'28.23
FS-GB
28.40FS
PROP.PROPERTY LINE
EX PROPERTYLINE
PROP. 0.4' DEDICATION TO
THE CITY OF LAKE ELSINORE
0.4'28.50
FL-HP
EX PROPERTY
LINE TO REMAIN
28.34TC
27.84FS
ADA PATH
OF TRAVEL
EX PROPERTY LINE
TO BE REMOVED BYSTREET VACATION
PROP.
PROPERTY LINE
PROP. SDMH AT
EX PUBILC SD LINE
EX SQ10=0.73cfs
SQ100=1.36cfsPROP SQ10=2.56cfs
SQ100=4.16cfs PROP. INLET
Q10=2.56cfs
Q100=4.16cfs
EX PROPERTY
LINE TO REMAIN
2%
MAX
PROP.PROPERTY LINE
EX PROPERTYLINE
PROP. 0.4' DEDICATION TO
THE CITY OF LAKE ELSINORE
0.4'6.5'TYP.EX STREETCENTERLINE
EX EDGE OF
PAVEMENT
37.89FS
ADA PATH
OF TRAVEL
SIGHT DIST.
"POINT C"
NUMBER DATE
REVISIONS
APP'V'D BENCHMARK:
HL
MLCHECKED BY:
DRAWN BY:
DATE:
PLANS PREPARED BY:
AARON M. ALBERTSON DATE
R.C.E. 65513, EXP. 09/30/23
01/11/23
01/11/2023
EL TORO DEVELOPMENT
EL TORO CUT OFF
LAKE ELSINORE, CA 92532
SHEET
OF
BASIS OF BEARINGS:EXIST. APN:
THE BASIS OF BEARINGS FOR THIS SURVEY IS THAT
PORTION OF THE CENTERLINE OF STATE HIGHWAY 74,
AS SHOWN ON SHEET 8 OF 15 ON ROS 123/94-108,
I.E. N 26°04'00" E.
THE BENCHMARK FOR THIS SURVEY IS USGS
BENCHMARK DESIGNATION "D 307," LOCATED AT THE
WESTERLY CORNER OF EL TORO CUTTOFF AND THE
NORTHERLY FRONTAGE ROAD.
ELEVATION = 1425.75 FEET (NAVD 88)
347-130-033
347-130-034
347-130035
07
CG-02
CONCEPTUAL GRADING
(XXX.XX)EXISTING ELEVATION
APN ASSESSOR'S PARCEL NO.
℄CENTER LINE
EX EXISTING
FG FINISH GROUND
FL FLOWLINE
FS FINISH SURFACE
GB GRADE BREAK
INV INVERT
LF LINEAR FEET
LS LANDSCAPE AREA
PL PROPERTY LINE
ROW RIGHT OF WAY
SD STORM DRAIN
TC TOP OF CURB
TG TOP OF GRATE
TY TYPICAL
02MATCHLINEMATCHLINEMATCHLINEEXISTING CONCRETE
PROPOSED ASPHALT
PROPOSED CONCRETE
LANDSCAPING
PROPERTY LINE
CENTERLINE
GRADING LIMITS
SIGHT DISTANCE
PROPOSED SEWER LINE
PROPOSED STORM LINE
PROPOSED WATER LINE
PROPOSED IRRIGATION LINE
PROPOSED CONTOUR
EXISTING CONTOUR
EXISTING SEWER LINE
EXISTING WATER LINE
LEGEND
SD SD
W
IW
SS
W
XX
XX
ABBREVIATIONS:
NOPARKINGVANNOPARKINGPROPOSED
BUILDING
FRONT
A
G
E
R
O
A
D
EL TORO CUT OFF RDHIGHWAY 74
FRONT
A
G
E
R
O
A
D
HIGHWAY 74
ROSETTA CANYON DRIVEPROPOSED
BUILDING
PROP. PERFORATED CMP
W/ ORIFICE OUTLET FOR
FLOW CONTROL
REMOVE EX STANDING
DRAIN & CAP EX SD PIPE.
EX 24" PUBLIC
STORM DRAIN
EX PUBLIC
SEWER MAIN
PROP. SANITARY
SEWER CONNECTION
PROP. SANITARY
SEWER MANHOLE
PROP. SANITARY
SEWER MANHOLE
PROP. CONNECTION TO EX 12"
D.I. WATER MAIN FOR DOMESTIC
AND IRRIGATION WATER SERVICE PROP. CONNECTION TO EX 12" D.I.
WATER MAIN FOR DOMESTIC AND
IRRIGATION WATER SERVICE
PROP. MODULAR WETLAND
SYSTEM #2 (BMP-4)
PROP. BLDG WATER
LINE CONNECTION
EX 24" PUBLIC
STORM DRAIN
PROP. BLDG WATER
LINE CONNECTION
EX DISCHARGE POINT AT
EX HEADWALL TO REMAIN
PROP. CONNECTION
TO BLDG SEWER LINE
PROP. SANITARY
SEWER MANHOLE
PROP. SANITARY
SEWER MANHOLE
PROP. CONNECTION
TO BLDG SEWER LINE
PROP. STORM DRAIN INLET IN PUBLIC ROW
TO BE MAINTAINED BY PROJECT OWNER
PROP. SD LINE IN PUBLIC ROW TO BE
MAINTAINED BY CITY OF LAKE ELSINORE
PROP. PRIVATE
STORM DRAIN LINE
PROP. TRENCH
DRAIN
PROP. STORM
DRAIN INLET
EX WATER MAIN
EX WATER MAIN
PROP. 8" PUBLIC
SEWER LINE
PROP. DOMESTIC
WATER LATERAL
PROP. IRRIGATION
WATER LATERAL PROP. DOMESTIC
WATER LATERAL
PROP. IRRIGATION
WATER LATERAL
PROP. CONNECTION
TO SEWER LINE
PROPOSED
SEWER LINE
PROP. UNDERGROUND
GREASE INTERCEPTOR
PROP. UNDERGROUND
GREASE INTERCEPTOR
PROP. 8" PUBLIC
SEWER LINE
PROPOSED
SEWER LINEPROP. STORM DRAIN INLET
FOR MAINTENANCE CHANGES
PROP. STORM DRAIN INLET FOR
MAINTENANCE CHANGES
PROP. SD LINE IN PUBLIC ROW TO BE
MAINTAINED BY CITY OF LAKE ELSINORE
PROP. SANITARY
SEWER MANHOLE
PROP. SIDEWALK
CURB DRAIN
Q10=0.43cfs
Q100=0.73cfs
END OF PROP. GUTTER
EX: SQ10=2.29cfs;SQ100=4.11cfs
PROP: SQ10=3.57cfs;SQ100=5.97cfs
PROP. SIDEWALK
UNDERDRAIN
Q10=2.63cfs
Q100=4.31cfs
POINT OF CONNECTION TO EX
STORM DRAIN LINE VIA SDMH
EX: SQ10=0.73cfs;SQ100=1.36cfs
PROP: SQ10=2.56cfs;SQ100=4.16cfs
PROP.STORM
DRAIN INLET
Q10=2.56cfs
Q100=4.16cfs
PROP. BIORETENTION
BASIN #2 (BMP-2)
PROP. BIORETENTION
BASIN #1 (BMP-1)
PROP. 8" PUBLIC
SEWER LINE
PROP. PERFORATED CMP
W/ ORIFICE OUTLET FOR
FLOW CONTROL
PROP. MODULAR WETLAND
SYSTEM #1 (BMP-3)
PROP. MODULAR WETLAND
SYSTEM #3 (BMP-5)
PROPOSED
SEWER LINE
PROP. 0.4' DEDICATION TO
THE CITY OF LAKE ELSINORE
PROP.
PROPERTY LINE
EX PROPERTY
LINE
EX PROPERTYLINE TO REMAIN
EX PROPERTYLINE TO REMAIN
EX PROPERTY LINE
TO BE REMOVED BY
STREET VACATION
PROP. PROPERTY LINEPROP. PRIVATE
STORM DRAIN LINE
PROP. PRIVATE
SD LINE
PROP. PRIVATE
SD LINE
PROP. 0.4' DEDICATION TO
THE CITY OF LAKE ELSINORE
PROP.
PROPERTY LINE
EX PROPERTYLINE
PROP. SD LINE IN PUBLIC ROW TO BE
MAINTAINED BY CITY OF LAKE ELSINORE
PROP. PRIVATE
SD LINE
CG-03
CONCEPTUAL WET UTILITY PLAN
NUMBER DATE
REVISIONS
APP'V'D BENCHMARK:
HL
MLCHECKED BY:
DRAWN BY:
DATE:
PLANS PREPARED BY:
AARON M. ALBERTSON DATE
R.C.E. 65513, EXP. 09/30/23
01/11/23
01/11/2023
EL TORO DEVELOPMENT
EL TORO CUT OFF
LAKE ELSINORE, CA 92532
SHEET
OF
BASIS OF BEARINGS:EXIST. APN:
THE BASIS OF BEARINGS FOR THIS SURVEY IS THAT
PORTION OF THE CENTERLINE OF STATE HIGHWAY 74,
AS SHOWN ON SHEET 8 OF 15 ON ROS 123/94-108,
I.E. N 26°04'00" E.
THE BENCHMARK FOR THIS SURVEY IS USGS
BENCHMARK DESIGNATION "D 307," LOCATED AT THE
WESTERLY CORNER OF EL TORO CUTTOFF AND THE
NORTHERLY FRONTAGE ROAD.
ELEVATION = 1425.75 FEET (NAVD 88)
347-130-033
347-130-034
347-130035
0703
(XXX.XX)EXISTING ELEVATION
APN ASSESSOR'S PARCEL NO.
℄CENTER LINE
EX EXISTING
FG FINISH GROUND
FL FLOWLINE
FS FINISH SURFACE
GB GRADE BREAK
INV INVERT
LF LINEAR FEET
LS LANDSCAPE AREA
PL PROPERTY LINE
ROW RIGHT OF WAY
SD STORM DRAIN
TC TOP OF CURB
TG TOP OF GRATE
TY TYPICAL
EXISTING CONCRETE
PROPOSED ASPHALT
PROPOSED CONCRETE
LANDSCAPING
PROPERTY LINE
CENTERLINE
GRADING LIMITS
SIGHT DISTANCE
PROPOSED SEWER LINE
PROPOSED STORM LINE
PROPOSED WATER LINE
PROPOSED IRRIGATION LINE
EXISTING CONTOUR
EXISTING SEWER LINE
EXISTING WATER LINE
LEGEND
SD SD
W
IW
SS
W
XX
ABBREVIATIONS:
363438404234.26TC33.60FL37.20TC36.70FS37.38TC36.88FS37.55TC37.05FS34.46FG2.8%1.5%1.5%34.32FS4.00'7.50'12.00'7.08'PROP.SIDEWALKPROP.DRIVEWAYPROP.LANDSCAPEPROP.PARKINGEL TORO CUTOFF ROAD37.27FG2.59'PROP.LANDSCAPEPROPOSED RETAINING WALL PERSEPARATE PLAN AND PERMIT2.0%3.0%3634384042EXISTINGEDGE OF PAVEMENT39.01'VARIESVARIESPROP.AC PAVEMENTEX.AC PAVEMENT2.0%PROPOSED 42"GAURDRAIL44℄⅊14
3
2
1
4
2
8
1438
14
3
4
14321434
1442
1444
1446
1448
14
3
2∆=04° 12' 47" R = 1034.25' L=76.05'N81°39'22"E31.97'∆
=
0
5
°
0
4
'
4
0
"
R
=
3
2
6
6
.
6
0
'
L
=
2
8
9
.
5
0
'∆=0
5
°
4
2
'
4
5
"R =
6
8
6
.
7
1
'
L=
6
8
.
4
7
'N83°29'46"E 62.58'N58°09
'32
"E
114
.21
'
N01°23'36"E
30.48'
∆
=
9
6
°
2
8
'
5
0
"
R
=
4
6
.
4
0
'
L
=
7
8
.
1
3
'∆=03° 31' 39" R = 934.25' L=57.52'S58°04
'59
"W
120
.32
'
∆
=
0
5
°
0
3
'
4
3
"
R
=
3
2
6
7
.
0
0
'
L
=
2
8
8
.
6
3
'NOPARKING36
.
0
0
'EL TORO CUT OFF RDFF
=
3
8
.
0
0
PA
D
=
3
7
.
5
9 FFG
G
HI
G
H
W
A
Y
7
4 FRONTAGE ROAD
36
.
0
0
'3028323436403842302832343640384239.73TC39.07FL38.01TC37.51FL38.00TC37.50FS36.64TC36.14FS30.88TC30.21FLPROP. 1 STORY BUILDINGFF = 38.0037.82TC37.32FS37.90FS6.5'31.06FS30.97FSPROP.SIDEWALK⅊PROPOSED 0.4'DEDICATIONEXISTINGPROPERTY LINEPROP.LANDSCAPEPROP.LANDSCAPEPROP.DRIVE-THRULANEPROP.SIDEWALKPROP.DRIVEWAYPROP.PARKINGHIGHWAY 74FRONTAGE ROAD2.0%2.0%2.5%1.5%2.0%1.5%37.0%5.5'6.7'12.0'6.0'4.4'4.5'29.0'18.0'39.83FS39.94FGPROPOSED RETAINING WALL PERSEPARATE PLAN AND PERMITPROP.SIDEWALK4444℄22.9'EXISTINGEDGE OF PAVEMENT⅊VARIESVARIESPROP.LANDSCAPEPROP.AC PAVEMENTEX.AC PAVEMENTPROP. 1' BENCH39.92FGPROPOSED 42"GAURDRAILNUMBERDATEREVISIONSAPP'V'DBENCHMARK:HLMLCHECKED BY:DRAWN BY:DATE:PLANS PREPARED BY:AARON M. ALBERTSONDATER.C.E. 65513, EXP. 09/30/2301/11/2301/11/2023EL TORO DEVELOPMENTEL TORO CUT OFFLAKE ELSINORE, CA 92532SHEETOFBASIS OF BEARINGS:EXIST. APN:THE BASIS OF BEARINGS FOR THIS SURVEY IS THATPORTION OF THE CENTERLINE OF STATE HIGHWAY 74,AS SHOWN ON SHEET 8 OF 15 ON ROS 123/94-108,I.E. N 26°04'00" E.THE BENCHMARK FOR THIS SURVEY IS USGSBENCHMARK DESIGNATION "D 307," LOCATED AT THEWESTERLY CORNER OF EL TORO CUTTOFF AND THENORTHERLY FRONTAGE ROAD.ELEVATION = 1425.75 FEET (NAVD 88)347-130-033347-130-034347-13003507KEY MAPSCALE: 1"=30'SECTION "G-G"SCALE:1"=5'SECTION "F-F"SCALE:1"=5'CG-05SECTIONS05
30
28
32
34
36
30
28
32
34
36
PROP. 1 STORY BUILDING
FF = 28.72
28.51
FS 28.00TC
27.50FS 27.64TC
27.14FS
33.28
FS
33.15TC
32.48FL
⅊
10.76'12.00'20.96'11.67'5.50'6.50'
PROP.
SIDEWALK
PROP.
LANDSCAPE
PROP.
DRIVE-THRU
LANE
PROP.
LANDSCAPE
PROP.
SIDEWALK
PROPOSED 0.4'
DEDICATION
EXISTING
PROPERTY LINE
32.39
FG HIGHWAY 74
26.01TC
25.51FL
26
⅊
26.10
FS
26.38
FG
28.51TC
28.01FL
28.11
FG28.51
FG
28.91TC
28.41FS
11.50'6.50'15.37'3.50'4.0'
PROP.
LANDSCAPE
PROP.
LANDSCAPE
PROP.
DRIVEWAY
PROP.
SIDEWALK
2.0%8.0%
14.0%
13.0%13.0%3.0%2.0%4.0%
3.0%
1.6%
22.0%
FRONTAGE
ROAD
PROP.
SWALE
1' BENCH
32.37FG 141614321416142814261424142214221418141614181436143414321438142814261424142214141412142614281424142214141412140814061404140214181434141014201430142014201430143014001420DIRTROADPOWER POLEFIRE HYDRANTPOWER POLEPOWER POLEPOWER POLEPOWER POLETRAFFICUTILITYBOXSIGNWATERVALVEST NAME SIGNSTOPSIGN3' DIA. STAND PIPEFL 1427.44SIGNAL LIGHT SIGNBUS STOP SIGNBENCHTRAFFICSIGNAL BOXST NAMESIGNTRAFFICSIGNAL BOXTRAFFICSIGNAL BOXLIGHTDIRTWALKINGPATHSTOPSIGNHEADWALLST NAMESIGNFL 1421.30FL 1421.26FL 1424.9824" CMP50'50'50'50'30'N14°21'34"E 387.94'N26°04'00"E 229.00'N64°20'02"W 124.88'N09°37'26"W33.67'N86°18'05"E31.75'N58°57'31"W (R)∆=07° 12' 32" R = 3266.60' L=411.00'∆=04° 12' 47" R = 1034.25' L=76.05'∆=13° 14' 57" R = 686.71' L=158.00'∆=11° 23' 45" R = 666.71' L=132.61'EX. WATER LINEFROM AS BUILT EVMWDSHT 4209N81°39'22"E
31.97'N01°23'36"E∆=03° 31' 39" R = 934.25' L=57.52'N64°14'50"W (R)FRONTAGE ROADHIGHWAY 74EL TORO CUT OFF ROADNOPA
R
K
I
N
G
VA
N ∆=05° 03' 43" R = 3267.00' L=288.63'∆=07° 12' 59" R = 3267.00' L=411.48'N26°04'00"E 227.07'NOPARKINGA
A
E
ECC
B
B
D
D FF=28.72PAD=28.22FRONTAGE ROADEL TORO CUT OFF RDHIGHWAY 74PAD=37.5924
22
26
28
⅊
24
22
26
28
22.79TC
22.12FL
26.86TC
26.36FS
22.88
FS
23.91'8.48'
30 30
PROP.
SIDEWALK
4.50'
PROP.
LANDSCAPE
PROP. LANDSCAPE27.02
FG
17.0%
2.0%
2.0%
℄
FRONTAGE RD
24.00'
VARIES VARIES
2.8%
EX.
AC PAVEMENT
PROP.
AC PAVEMENT
EXISTING
EDGE OF PAVEMENT
30
28
32
34
36
30
28
32
34
36 EL TORRO CUT OFF ROAD
34.04TC
33.37FL
⅊
34.13
FS
3838
28.58TC
28.08FS
4.50'7.50'20.23'
PROP.
LANDSCAPE
PROP.
LANDSCAPE
PROP.
SIDEWALK
33.98
FG
30.0
%
2.0%2.0%
℄
38.00'
VARIESVARIES
PROP.
AC PAVEMENT
EX.
AC PAVEMENT 2.6%
EXISTING
EDGE OF PAVEMENT
PROP. 1' BENCH
33.96FG
PROP. 1' BENCH
28.60FG
24
22
26
28
24
22
26
28
30 30
26.96TC
26.46FS
25.10
FG 24.84TC
24.17FL
⅊
PROPOSED 0.4'
DEDICATION EXISTING
PROPERTY LINE
21.29'12.00'
PROP.
LANDSCAPE
PROP.
LANDSCAPE
HIGHWAY 74
8.7%
2.0%
℄
55.00'
VARIES VARIES
0.9%
EX.
AC PAVEMENT
PROP.
AC PAVEMENT
EXISTING CURB AND GUTTER
TO BE REMOVED FOR STREET WIDENING
14
12
16
18
20
22
15.48TC
14.81FL14.56
FS
15.57
FS
14
12
16
18
20
22
4.05'10.50'
PROP.
LANDSCAPE
PROP.
SIDEWALK
FRONTAGE
ROAD
2.0%
NUMBER DATE
REVISIONS
APP'V'D BENCHMARK:
HL
MLCHECKED BY:
DRAWN BY:
DATE:
PLANS PREPARED BY:
AARON M. ALBERTSON DATE
R.C.E. 65513, EXP. 09/30/23
01/11/23
01/11/2023
EL TORO DEVELOPMENT
EL TORO CUT OFF
LAKE ELSINORE, CA 92532
SHEET
OF
BASIS OF BEARINGS:EXIST. APN:
THE BASIS OF BEARINGS FOR THIS SURVEY IS THAT
PORTION OF THE CENTERLINE OF STATE HIGHWAY 74,
AS SHOWN ON SHEET 8 OF 15 ON ROS 123/94-108,
I.E. N 26°04'00" E.
THE BENCHMARK FOR THIS SURVEY IS USGS
BENCHMARK DESIGNATION "D 307," LOCATED AT THE
WESTERLY CORNER OF EL TORO CUTTOFF AND THE
NORTHERLY FRONTAGE ROAD.
ELEVATION = 1425.75 FEET (NAVD 88)
347-130-033
347-130-034
347-130035
07
SECTION "E-E"
SCALE:1"=5'
SECTION "A-A"
SCALE:1"=5'
KEY MAP
SCALE: 1"=50'
SECTION "B-B"
SCALE:1"=5'
SECTION "C-C"
SCALE:1"=5'
KEY MAP
SCALE: 1"=50'
SECTION "A-A"
SCALE:1"=5'
SECTION "B-B"
SCALE:1"=5'
SECTION "C-C"
SCALE:1"=5'
SECTION "C-C"
SCALE:1"=5'
SECTION "D-D"
SCALE:1"=5'
CG-04
SECTIONS
04
NOPARKING
VANNOPARKINGFRONT
A
G
E
R
O
A
D
EL TORO CUT OFF RDHIGHWAY 74
FR
O
N
T
A
G
E
R
O
A
D
HIGHWAY
7
4
ROSETTA CANYON DRIVES
HIGHWAY 74 PER SIGHT DISTANCE DETAIL NO. 126
Y1 X X1
550'6'29'6'
S
FRONTAGE ROAD PER SIGHT DISTANCE DETAIL NO. 126
Y1 X X1
175'0'0'0'
URBAN ARTERIAL
LOCAL
SPEED
EL TORO CUTOFF ROAD PER INTERSECTION SIGHT DISTANCE STD NO. 821
S
25 MPH 275'
LOCAL
55 MPH 605'
SIGHT DIST.
"POINT A"
SIGHT DIST.
"POINT C"
SIGHT DIST.
"POINT C"
SIGHT DIST.
"POINT C"
SIGHT DIST.
"POINT A"
SIGHT DIST."POINT B"
SIGHT DIST."POINT A"
SIGHT DIST.
"POINT C"
S = 550'
SECONDARY ARTERIAL
S = 550'
SECONDARY ARTERIAL
S = 175'
LOCAL
S = 175'LOCAL
S = 175'
LOCAL
S = 175'LOCAL
SIGHT DIST.
"POINT A"
SIGHT DIST."POINT B"
S = 605'
DESIGN SPEED = 55MPH
SIGHT DIST.
"POINT A"
SIGHT DIST.
"POINT B"
SIGHT DIST."POINT B"
S = 220'
DESIGN SPEED = 20MPH
SIGHT DIST.
"POINT C"
SIGHT DIST.
"POINT C"
CG-06
SIGHT DISTANCE EXHIBIT
06
NUMBER DATE
REVISIONS
APP'V'D BENCHMARK:
HL
MLCHECKED BY:
DRAWN BY:
DATE:
PLANS PREPARED BY:
AARON M. ALBERTSON DATE
R.C.E. 65513, EXP. 09/30/23
01/11/23
01/11/2023
EL TORO DEVELOPMENT
EL TORO CUT OFF
LAKE ELSINORE, CA 92532
SHEET
OF
BASIS OF BEARINGS:EXIST. APN:
THE BASIS OF BEARINGS FOR THIS SURVEY IS THAT
PORTION OF THE CENTERLINE OF STATE HIGHWAY 74,
AS SHOWN ON SHEET 8 OF 15 ON ROS 123/94-108,
I.E. N 26°04'00" E.
THE BENCHMARK FOR THIS SURVEY IS USGS
BENCHMARK DESIGNATION "D 307," LOCATED AT THE
WESTERLY CORNER OF EL TORO CUTTOFF AND THE
NORTHERLY FRONTAGE ROAD.
ELEVATION = 1425.75 FEET (NAVD 88)
347-130-033
347-130-034
347-130035
07
(XXX.XX)EXISTING ELEVATION
APN ASSESSOR'S PARCEL NO.
℄CENTER LINE
EX EXISTING
FG FINISH GROUND
FL FLOWLINE
FS FINISH SURFACE
GB GRADE BREAK
INV INVERT
LF LINEAR FEET
LS LANDSCAPE AREA
PL PROPERTY LINE
ROW RIGHT OF WAY
SD STORM DRAIN
TC TOP OF CURB
TG TOP OF GRATE
TY TYPICAL
EXISTING CONCRETE
PROPOSED ASPHALT
PROPOSED CONCRETE
LANDSCAPING
PROPERTY LINE
CENTERLINE
GRADING LIMITS
SIGHT DISTANCE
LEGEND
ABBREVIATIONS:
NOPARKING
VANNOPARKINGFRONT
A
G
E
R
O
A
D
EL TORO CUT OFF RDHIGHWAY 74
FR
O
N
T
A
G
E
R
O
A
D
HIGHWAY
7
4
ROSETTA CANYON DRIVEPROPOSED PROPERTY LINE TO BE
ADDED BY STREET DEDICATION
PROPOSED PROPERTY LINE TO BEADDED BY STREET VACATION
EXISTING
CENTERLINE
EXISTING
CENTERLINE
FRONTAGE ROAD TO BE MAINTAINED
BY CITY OF LAKE ELSINORE
FRONTAGE ROAD TO BE MAINTAINED
BY CITY OF LAKE ELSINORE
FRONTAGE ROAD TO BE MAINTAINEDBY CITY OF LAKE ELSINORE
EXISTING
CENTERLINE
EXISTING
CENTERLINE
EXISTING
PROPERTY LINE
PROPOSED PROPERTY LINE TO BE
ADDED BY STREET DEDICATION
EXISTING
PROPERTY LINE
EXISTING PROPERTY TO BE
REMOVED BY STREET VACATION
EXISTINGPROPERTY LINE
EXISTING
PROPERTY LINE
12
0
.
3
3
'
PR
O
P
O
S
E
D
P
R
O
P
E
R
T
Y
L
I
N
E
PROPOSED STORM DRAIN TO BE
MAINTAINED BY CITY OF LAKE ELSINORE
PROPOSED STORM DRAIN DRAIN
INLET FOR MAINTENANCE CHANGES
PROPOSED STORM DRAIN DRAIN
INLET FOR MAINTENANCE CHANGES
PROPOSED STORM DRAIN
TO BE MAINTAINED BY
CITY OF LAKE ELSINORE
PROPOSED STORM DRAIN MANHOLE TO BE
MAINTAINED BY CITY OF LAKE ELSINORE
PROPOSED STORM DRAIN DRAIN INLET TO
BE MAINTAINED BY CITY OF LAKE ELSINORE
PROPOSED STORM DRAINTO BE MAINTAINED BY
CITY OF LAKE ELSINORE
PROPOSED PROPERTY LINE
REMOVED BY LOT LINE MERGER
PROPOSED SIDEWALK UNDERDRAIN TO BE
MAINTAINED BY CITY OF LAKE ELSINORE
PROPOSED STORM
DRAIN CURB DRAIN TO
BE MAINTAINED BY CITY
OF LAKE ELSINORE
PROPOSED STORMDRAIN INLET TO BEMAINTAINED BY CITYOF LAKE ELSINORE
CG-07
MAINTENANCE EXHIBIT
07
(XXX.XX)EXISTING ELEVATION
APN ASSESSOR'S PARCEL NO.
℄CENTER LINE
EX EXISTING
FG FINISH GROUND
FL FLOWLINE
FS FINISH SURFACE
GB GRADE BREAK
INV INVERT
LF LINEAR FEET
LS LANDSCAPE AREA
PL PROPERTY LINE
ROW RIGHT OF WAY
SD STORM DRAIN
TC TOP OF CURB
TG TOP OF GRATE
TY TYPICAL
ABBREVIATIONS:
EXISTING CONCRETE
PROPOSED ASPHALT
PROPOSED CONCRETE
LANDSCAPING
PROPERTY LINE
CENTERLINE
LEGEND
NUMBER DATE
REVISIONS
APP'V'D BENCHMARK:
HL
MLCHECKED BY:
DRAWN BY:
DATE:
PLANS PREPARED BY:
AARON M. ALBERTSON DATE
R.C.E. 65513, EXP. 09/30/23
01/11/23
01/11/2023
EL TORO DEVELOPMENT
EL TORO CUT OFF
LAKE ELSINORE, CA 92532
SHEET
OF
BASIS OF BEARINGS:EXIST. APN:
THE BASIS OF BEARINGS FOR THIS SURVEY IS THAT
PORTION OF THE CENTERLINE OF STATE HIGHWAY 74,
AS SHOWN ON SHEET 8 OF 15 ON ROS 123/94-108,
I.E. N 26°04'00" E.
THE BENCHMARK FOR THIS SURVEY IS USGS
BENCHMARK DESIGNATION "D 307," LOCATED AT THE
WESTERLY CORNER OF EL TORO CUTTOFF AND THE
NORTHERLY FRONTAGE ROAD.
ELEVATION = 1425.75 FEET (NAVD 88)
347-130-033
347-130-034
347-130035
07
1432
1416 142814261424
1422
1422
1418
142814
1421414140814341411420
14301420
143024" CMP50'
50'30'FRONT
A
G
E
R
O
A
D
N14°21'
3
4
"
E
3
8
7.
9
4'
4'0 0 "E 229 .0 0'N64°20'02"W 124.88'N09°37'2
6
"
W33.67'N86°18'05"E31.75'N58°57'31"W (R)
∆=07° 12' 32" R = 3266.60' L=411.00'∆=04° 12' 47" R = 1034.25' L=76.05'∆=13° 14' 57" R = 686.71' L=158.00'
∆=11° 23'
4
5
"
R
=
6
6
6
.
7
1'
L
=
1
3
2
.
6
1'
N64°14'50"W (R)
FF=28.72
PAD=28.22NOPARKING
VAN∆=07° 12' 59" R = 3267.00' L=
4
1
1
.
4
8
'
N26°04'00"E 227
.
0
7
'
LOT AREA:
1.09 ACRES
MK 10B
2,649 SF
1 2 3 4
5
6
7
8
9111213WWW
WWWWWWIW
IWSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDMK11_SM
PLANNING SUBMITTAL 11.08.2021
2643 4th Avenue
San Diego CA 92103
phone 619.544.1977
angelina@asotelo.com
www.asotelo.com
LANDSCAPE
CONCEPT
PLAN
L1.0
0LANDSCAPE CONCEPT PLAN ASCALE 1"=20'-0"
10'20'40'MATCHLINE - SEE BELOW141214140TRAFFIC
SIGNAL BOX
N2
SDMATCHLINE - SEE ABOVE15' SIGHT TRIANGLE PER CITY OF LAKE
ELSINORE STANDARDS: NO TREES AND NO
SHRUBS OR OTHER LANDSCAPE FEATURES
EXCEEDING 36" SHALL BE LOCATED WITHIN
THIS TRIANGLE, TYPICAL
GROUNDCOVERS ALL COBBLE AREAS SHALL
BE 4"-8" 'ARIZONA COBBLE'
SET OVER 'MIRIFI MSCAPE'
LANDSCAPE FABRIC, PER
DETAIL, TYPICAL
GROUNDCOVERS LARGE BROADLEAF
TREES
MEDIUM FLOWERING
TREES
BIORETENTION
SHRUBS MATCHLINE - SEE SHEET L1.1MAXIMUM ALLOWABLE WATER ALLOWANCE (MAWA):
(ETo) x (0.62) x [(0.45) x LA]
(49.7 x (0.62) x [(0.45) x 49,086.42]= 680,647.02
ESTIMATED TOTAL WATER USE (ETWU):
(ETo) x (0.62) x [(PF x HA)/IE]
(49.7) x (0.62) x [(0.2 x 41,274.26)/0.81]= 314,030.87
HYDROZONE 1
LOW WATER USE SHRUBS WITH DRIP IRRIGATION
451,238.83
ETWU = 451,238.83 < MAWA = 680,647.02
(49.7) x (0.62) x [(0.5 x 128)/0.75]= 2,629.46
HYDROZONE 3
MEDIUM WATER USE TREES WITH BUBBLER IRRIGATION
(49.7) x (0.62) x [(0.5 x 6,612.16)/0.81]= 125,769.81
HYDROZONE 2
MODERATE WATER USE SHRUBS WITH DRIP IRRIGATION
(49.7) x (0.62) x [(0.2 x 1,072)/0.75]= 8,808.69
HYDROZONE 4
LOW WATER USE TREES WITH BUBBLER IRRIGATION*
HYDROZONE MAP BN.T.S.
*
*LOW WATER USE
SHRUBS WITH DRIP
IRRIGATION
MODERATE WATER
USE SHRUBS WITH
DRIP IRRIGATION
MEDIUM WATER USE
TREES WITH BUBBLER
IRRIGATION
LOW WATER USE
TREES WITH BUBBLER
IRRIGATION EL TORO CUT OFF ROADFF=28.72
PAD=28.22
FRONTA
G
E
R
O
A
D
HIGHWAY 74 NOPARKINGVAN∆=07° 12' 59" R = 3267.00' L=411.48'
N26°04'00"E 227.07'
LOT AREA:
1.09 ACRES
MK 10B 2,649 SF
1 2 3 4
5
6
7
8
9111213W
WSDSDSDSD SD SD SD SD SD SD SDSDSDSDSDSDSD
FRON
T
A
G
E
R
O
A
D
HIGHWAY 74
S58
°
0
4
'
5
9
"
W
1
2
0
.
3
2
'
∆=05° 03' 43" R = 3267.00' L=
2
8
8
.
6
3
'NOPARKING624 S.F.
SD
SD
SD
SD
SD
SD
SD
SD
SD
*****
***************************
************
*
*
***
*
*
*************
**
LARGE
BROADLEAF
TREES
MEDIUM
FLOWERING
TREES
UPRIGHT
SHRUBS
MEDIUM
FLOWERING
SHRUBS
BIO RETENTION
SHRUBS
VINES
ACCENT
SHRUBS
*
1428
143814321434
14421444
1446
4 8
1436
1440
14401430 14301432
HEAD
WALL
ST NAME
SIGN
FL 1424.98MP
50'30'50'30'30'66.6'EL TORO CUT OFF RDN81°39
'22
"E31.97
'
∆=05° 04' 40"
R
=
3
2
6
6
.
6
0
'
L
=
2
8
9
.
5
0
'
∆=0
5
°
4
2
'
4
5
"
R =
6
8
6
.
7
1
'
L=6
8
.
4
7
'
N5
8
°
0
9
'
3
2
"
E
1
1
4
.
2
1
'
N01°2
3'
3
6"
E
30.48'∆=03° 31' 39" R = 934.25' L=57.52'EL TORO CUT OFF ROADSD
SD
SD
SD
FR
O
N
T
A
G
E
R
O
A
D
HIGHWAY 74 XXXXXS5
8
°
0
4
'
5
9
"
W
1
2
0
.
3
2
'
∆=05° 03' 43" R = 326
7
.
0
0
'
L
=
2
8
8
.
6
3
'NOPARKING624 S.F.WWWIWSD
SD
SD
SD
SD
SD
SD
SD
SDSDSDSD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
MK11_SM
PLANNING SUBMITTAL 11.08.2021
2643 4th Avenue
San Diego CA 92103
phone 619.544.1977
angelina@asotelo.com
www.asotelo.com
LANDSCAPE
CONCEPT
PLAN
L1.1
0LANDSCAPE CONCEPT PLAN ASCALE 1"=20'-0"
10'20'40'
ABBR SIZE SCIENTIFIC NAME COMMON NAME
PLANT LIST
UPRIGHT SHRUBS
GROUNDCOVERS
RHA. U.M.15 GAL.RHAPHIOLEPIS UMBELLATA 'MINOR'DWARF YEDDO HAWTHORN
MEDIUM FLOWRING SHRUBS
ACCENT SHRUBS
LIG. TEX.5 GAL.LIGUSTRUM JAPONICUM 'TEXANUM'TEXAS PRIVET
PIT. C.C.5 GAL.PITTOSPORUM CRASSIFOLIUM 'COMPACTUM'DWARF KARO
WES. G.B.5 GAL.WESTRINGIA FRUTICOSA 'GREY BOX'DWARF COAST ROSEMARY
AGA. B.G.5 GAL.AGAVE 'BLUE GLOW'BLUE GLOW AGAVE
ALO. B.E.1 GAL.ALOE 'BLUE ELF' BLUE ELF ALOE
DIE. BIC.1 GAL.DIETES BICOLOR BICOLOR AFRICAN IRIS
LOM. LON.1 GAL.LOMANDRA LONGIFOLIA 'BREEZE'DWARF MAT RUSH
LOM. P.B.5 GAL.LOMANDRA 'PLATINUM BEAUTY'PLATINUM BEAUTY DWARF MAT RUSH
LARGE BROADLEAF TREES
MEDIUM FLOWERING TREES
PRO. CHI.PROSOPIS CHILENSIS CHILEAN MESQUITE24" BOX
QUE. AGR.QUERCUS AGRIFOLIA COAST LIVE OAK24" BOX
RHU. LAN.RHUS LANCEA AFRICAN SUMAC24" BOX
LAG. FAU.24" BOX LAVENDER CRAPE MYRTLE LAGERSTROEMIA FAURIEI 'MUSKOGEE' (STANDARD)
PRU. K.V.PRUNUS CERASIFERA 'KRAUTER VESUVIUS'PURPLE LEAF PLUM24" BOX
OLE. EUR.36" BOX FRUITLESS OLIVEOLEA EUROPAEA 'WILSONII' MULTI
NER. L.R.5 GAL.NERIUM OLEANDER 'LITTLE RED'LITTLE RED OLEANDER
ROS. T.B.5 GAL.ROSMARINUS OFFICINALIS 'TUSCAN BLUE'UPRIGHT ROSEMARY
WES. FRU.5 GAL.WESTRINGIA FRUTICOSA COAST ROSEMARY
RHA. PIN.5 GAL.RHAPHIOLEPIS INDICA 'PINKIE'PINKIE INDIAN HAWTHORN
5 GAL.CAL. L.J.CALLISTEMON 'LITTLE JOHN'DWARF BOTTLE BRUSH
GRE. LAN.
GOLDEN SPREADING LANTANALAN. N.G.5 GAL.LANTANA 'NEW GOLD'
WES. MUN.5 GAL.LOW COAST ROSEMARYWESTRINGIA FRUTICOSA MUNDI
CENTURY PLANT AGA. AME.5 GAL.AGAVE AMERICANA
AGA. GEM.5 GAL.AGAVE GEMINIFLORA TWIN-FLOWERING AGAVE
DAS. WHE.5 GAL.DASYLIRION WHEELERI DESERT SPOON
DIA. CAE.1 GAL.DIANELLA CAERULEA 'CASSA BLUE'CASSA BLUE FLAX LILY
RED YUCCA HES. PAR.5 GAL.HESPERALOE PARVIFLORA
MUH. CAP.5 GAL.HAIRAWN MUHLYMUHLENBERGIA CAPILLARIS
MUH. RIG.5 GAL.DEER GRASSMUHLENBERGIA RIGENS
PEN. RUB.5 GAL.PENNISETUM SETACEUM 'RUBRUM'PURPLE FOUNTAIN GRASS
ACA. RED.6' O.C.ACACIA REDOLENS ACACIA 5 GAL.
BAC. PIL.BACCHARIS PILULARIS PIGEON POINT DWARF COYOTE BRUSH30" O.C.1 GAL.
MYO. PAR.MYOPORUM PARVIFOLIUM MYOPORUM1 GAL.18" O.C.
ROS. O.P. ROSMARINUS OFFICINALIS PROSTRATUS PROSTRATE ROSEMARY 1 GAL.
MEDIUM
FLOWRING
SHRUBS
LARGE BROADLEAF
TREES
UPRIGHT
SHRUBS
36" O.C.
5 GAL.GREVILLEA LANIGERA 'MT TAMBORITHA'PROSTATE WOOLY GREVILLEA
BIO RETENTION SHRUBS
CAR. DIV.CAREX DIVULSA EUROPEAN GREY SEDGE1 GAL.
CHO. TEC.CHONDROPETALUM TECTORUM SMALL CAPE RUSH1 GAL.
JUN. PAT.1 GAL.JUNCUS PATENS 'ELK BLUE'BLUE ELK CALIFORNIA RUSH
VINES
FIC. PUM.5 GAL.FICUS PUMILA CREEPING FIG MATCHLINE - SEE SHEET L1.0PRO. CHI.QUE. AGR.RHU. LAN.LAG. FAU.PRU. K.V.OLE. EUR.LIG. TEX.NER. L. R.ROS. T.B.WES. FRU.
CAL. L.J.GRE. LAN.LAN. N.G.PIT. C.C.RHA. U.M.RHA. PIN.WES. G.B.WES. MUN.AGA. B.G.AGA. AME.
AGA. GEM.ALO. B.E.DIE. BIC.LOM. LON.LOM. P.B.DAS. WHE.DIA. CAE.HES. PAR.MUH. CAP.MUH. RIG.
PEN. RUB.ACA. RED.BAC. PIL.MYO. PAR.ROS. O.P. CAR. DIV.CHO. TEC.JUN. PAT.FIC. PUM.
MEDIUM
FLOWERING
TREES
GROUNDCOVERS
VINES
ACCENT
SHRUBS
ACCENT
SHRUBS
EL TORO CUT OFF ROADFF=28.72PAD=28.22
FRONTA
G
E
R
O
A
D
HIGHWAY 74 NOPARKING
VAN∆=07° 12' 59" R = 3267.00' L=411.48'
N26°04'00"E 227.07'
LOT AREA:
1.09 ACRES
MK 10B 2,649 SF
1 2 3 4
5
6
7
8
9111213W
WSDSDSDSD SD SD SD SD SD SD SDSDSDSDSDSDSD
FRON
T
A
G
E
R
O
A
D
HIGHWAY 74
S58
°
0
4
'
5
9
"
W
1
2
0
.
3
2
'
∆=05° 03' 43" R = 3267.00' L
=
2
8
8
.
6
3
'NOPARKING624 S.F.
SD
SD
SD
SD
SD
SD
SD
SD
SD
TOTAL LOT AREA
47,989.14 SQ. FT.
(100%)
TOTAL LOT AREA
15,891.61 SQ. FT.
(100%)
LANDSCAPED COVERAGE BN.T.S.
LANDSCAPED AREA
INSIDE PROPERTY LINE
24,648.84 SQ. FT.
(51.36%)
LANDSCAPED AREA
INSIDE PROPERTY LINE
3,444.62 SQ. FT.
(21.67%)
MK11_SMPLANNING SUBMITTAL 11.08.20212643 4th AvenueSan Diego CA 92103phone 619.544.1977angelina@asotelo.comwww.asotelo.comPLANTINGNOTES &DETAILSL1.2PLANTING NOTES1. LANDSCAPE CONTRACTOR SHALL RECEIVE THE SITE WITHIN PLUS OR MINUS .10 FEET OF FINISH GRADE.2. THE PLANTING PLANS ARE DIAGRAMMATIC. MINOR ADJUSTMENTS IN PLANT LOCATIONS AND TYPE MAY BE MADE AT THE DISCRETION OF THELANDSCAPE ARCHITECT.3. CONTRACTOR TO BE ADVISED THAT CERTAIN CULTIVARS OR SPECIES OF PLANTS FOR THIS PROJECT MAY ONLY BE AVAILABLE THROUGHRETAIL SOURCES (IE.: PATENED MONROVIA SELECTIONS). CONTRACTOR IS FURTHER ADVISED THAT ALL PLANT MATERIAL FOR THIS PROJECTSHALL BE "PREMIUM" NURSERY STOCK.4. ALL PLANT MATERIAL SHALL BE SUBJECT TO THE APPROVAL OF THE LANDSCAPE ARCHITECT AND REPLACED UPON REQUEST BEFORE ORAFTER THE PLANTING.5. THE LANDSCAPE CONTRACTOR WILL COORDINATE HIS WORK WITH THE OTHER TRADES AND MAINTAIN DRAINAGE DURING CONSTRUCTION.6. PLANT QUANTITIES AND AREAS SHOWN ON LEGENDS ARE FOR CONTRACTORS' CONVENIENCE IN ESTIMATING ONLY. CONTRACTOR ISRESPONSIBLE FOR PROVIDING PLANT MATERIALS TO COVER ALL AREAS AS SHOWN ON PLANS.7. SLOPE ALL PLANTING AREAS AWAY FROM BUILDING AT 2% MINIMUM FOR 5 FEET MINIMUM, WHERE APPLICABLE.8. LANDSCAPE ARCHITECT SHALL APPROVE FINAL PLACEMENT OF ALL SHRUBS, AND VINES PRIOR TO PLANTING.9. SHRUB PITS 5 GALLONS AND SMALLER SHALL BE TWO TIMES ROOTBALL DIAMETER WIDE AND 1-1/2 TIMES CONTAINER DEPTH.10. SHRUB PITS 15 GALLONS AND LARGER SHALL BE TWO TIMES ROOTBALL DIAMETER WIDE AND 1" LESS THAN CONTAINER DEPTH.11. DO NOT DAMAGE PLANT ROOTBALL DURING TRANSPORTATION OR PLANTING.12. CONTRACTOR SHALL USE THE FOLLOWING AMENDMENT SCHEDULE FOR BIDDING PURPOSES ONLY. A SOIL TEST SHALL BE MADE BY THECONTRACTOR AND THE RESULTS SHALL BE SUBMITTED TO THE LANDSCAPE ARCHITECT FOR INCLUSION IN THE LANDSCAPE PLANS, AND THERECOMMENDED AMENDMENTS SHALL BE USED FOR ACTUAL INSTALLATION.100 LBS. OF GYPSUM PER 1000 SQ. FT.70 LBS. OF TRI-C (6-2-4 W/ 5% SULFUR) PER 1000 SQ. FT.6 LBS. OF IRON SULFATE PER 1000 SQ. FT.25 LBS. OF SOIL SULFUR PER 1000 SQ. FT.5 CUBIC YARDS OF NITROLIZED ORGANIC AMENDMENT PER 1000 SQ. FT. (SEE NOTE 16)13. AMENDED SOIL SHALL BE ROTOTILLED TO A DEPTH OF 8".14. NO IRON SULFATE SHALL COME IN CONTACT WITH ANY MASONRY SURFACE.15. NITROLIZED ORGANIC AMENDMENT SHALL BE HUMIC COMPOST FROM AGRI-SERVICE, LOAMEX™, OR APPROVED EQUAL.16. A. PLANTING BACKFILL MIX FOR ALL CONTAINER PLANTS SHALL CONSIST OF 1/3 NITROLIZED ORGANIC AMENDMENT AND 2/3 EXISTING SOIL,PLUS 2-1/2 LBS. OF SOIL SULFUR, 2 LBS. IRON SULFATE PER CU. YD., 4 LBS. GYPSUM, AND 8 LBS. OF TRI-C (6-2-4 W/ 5% SULFUR) PER CUBIC YARD.B. ALL PLANTED AREAS SHALL BE WATERED IN THOROUGHLY WITH SARVON™, PER MANUFACTURERS SPECIFICATIONS IN ADVANCE OFPLANTING.C. ALL PLANTS SHALL BE WATERED THOROUGHLY WITH SUPERTHRIVE™ WITHIN 1 HOUR OF PLANTING.17. ALL PLANTS 1-GALLON SIZE OR LARGER SHALL RECEIVE AGRIFORM 21-GRAM 20-10-5 FERTILIZER TABLETS AT THE FOLLOWING RATES:ONE PER 1-GALLON; TWO PER 5-GALLON; FIVE PER 15-GALLON; 12 PER 24" BOXED TREES; 18 PER 36" BOXED TREES (SEE L.A. FOR RATES FORLARGER STOCK). PLACE TABLETS AT HALF THE DEPTH OF THE PLANTING PIT AND 1" FROM ROOTBALL (BOXED TREES SHALL BE IN 2 LAYERSGOING UP ALONG SIDES OF THE ROOTBALL).18. ALL PLANTS INSTALLED FROM FLATS SHALL RECEIVE ONE AGRIFORM 5-GRAM 20-10-5 TABLET EACH, AND ALL 4" POTS SHALL RECEIVE TWO5-GRAM TABLETS EACH, MIXED WITH A HANDFUL OF PREPARED BACKFILL PER NOTE 17.19. ALL PLANTS PLANTED FROM CONTAINERS SHALL HAVE THEIR ROOTBALLS SCORED WITH A SHARP TOOL TO A DEPTH OF 1" IN THREELONGITUDINAL INCISIONS AT LOCATIONS SPACED AROUND THE ROOTBALL BEFORE PLACING PLANT IN PLANTING HOLE.20. ALL TYING MATERIALS AND MARKING TAPES SHALL BE REMOVED AT THE TIME OF PLANTING.21. STAKES SHALL BE REMOVED FROM VINES AND VINES SHALL BE PROVIDED WITH AN APPROVED MEANS OF SUPPORT.22. ALL SHRUB PLANTING AREAS SHALL BE COVERED WITH A 3" DEEP LAYER OF SHREDDED FIR BARK, OR APPROVED EQUAL. ALL BARK TO BENITROLIZED WITH 5% NITROGEN. WHEN GRAVEL OR COBBLE GROUNDCOVER IS USED, A LANDSCAPE FILTER FABRIC MUST BE INSTALLED, WITHAN OVERLAP OD 12" MIN. BETWEEN ROLLS AND FASTENED WITH STAPLES FLUSH TO THE FABRIC TO PREVENT MOVEMENT.23. IF THE SOIL TEST PREVIOUSLY MENTIONED SHOWS THAT PERMEABILITY RATES ARE LESS THAN .5" PER HOUR, LANDSCAPE ARCHITECT MAYREQUIRE A TREE DRAIN SYSTEM.24. A LANDSCAPE MAINTENANCE PERIOD OF 90 DAYS SHALL BE CONSIDERED PART OF THIS CONTRACT. REFER TO THE PROJECTSPECIFICATIONS FOR DETAILS.THE CONTRACTOR SHALL ENSURE THAT ALL PLANTS RECEIVE SUPERTHRIVE VITAMIN SOLUTION ATTIME OF INSTALLATIONA SOIL TEST SHALL BE MADE BY LANDSCAPE CONTRACTOR PRIOR TO THE BEGINNING OF WORK AND THE RECOMMENDATIONSMUST BE USED FOR INSTALLATION. SEE PLANTING NOTE 12.AN IRRIGATION AUDIT REPORT MAY BE REQUIRED BY THE CITY PRIOR TO CERTIFICATE OF OCCUPANCY.IF A CERTIFICATE OF COMPLETION IS REQUIRED BY THE CITY, PLEASE NOTIFY LANDSCAPE ARCHITECT 48 HOURS BEFOREINSPECTION.TREE PLANTINGNOT TO SCALESPACINGSHRUB PLANTINGNOT TO SCALECBNOTEEQUALSPACINGGROUNDCOVEREQUALSPACINGTRIANGULAR SPACING NOT TO SCALEDGROUNDCOVERS & SHRUBSSPACING(S) BETWEEN CENTERS OFPLANTS EQUAL IN ALL DIRECTIONS.SEE LEGEND FOR CLEARANCEBETWEEN PLANTS AND ADJACENTFLATWORK OR PAVING.PLANT GROUND COVERS TO WITHIN12" OF SHRUB PLANTING PITS,AND/OR TO THE EDGE OF DRIFTS OFPLANTS.COBBLE STREAMNOT SCALEDA2 TIMES WIDTHOF CONTAINER ATBOTTOM OF PITFOR DESERT TREES AND SHRUBS,PLANTING PITS SHALL BE 2X ROOTBALLAND BACKFILLED WITH NATIVE SOILS.1.PLANTING PIT 2 TIMES WIDTH & 1" LESSTHAN CONTAINER DEPTH. BACKFILL TOBE 1/3 NITROLIZED AMENDMENT, 2/3EXISTING SOIL, PLUS OTHERCORRECTIVES SHOWN ON PLANTINGNOTES.2.SCORE ROOT BALL W/ SHARP TOOL IN 3PLACES TO 1" DEPTH ALONG SIDES ANDBOTTOM BEFORE PLACING IN THEPLANTING PIT. APPLY SUPERTHRIVE ™,SARVON ™,WITHIN 2 HOURS OF PLANTING PERNOTES.3.4" HIGH WATERING BASIN # EDGE OFPLANTING PIT.4.LODGEPOLE TREE STAKE. DRIVE 2 FT.MIN. INTO UNDISTURBED SOIL. DO NOTPENETRATE ROOTBALL. KEEP TOP OFSTAKE BELOW TOP OF CANOPY.5.TIE W/ CINCH TIE, ARBORTAPE ORAPPROVED EQUAL, TWO TIES MIN. KEEPLOOSE.6.TOP OF STAKE TO BE 3" MAX. ABOVETOP TREE TIE & 6" BELOW CANOPY.7.TREE8.1-1/2" BARK MULCH AROUND TREE9.TOP OF ROOT BALL TO BE 1" ABOVESURROUNDING GRADE.10.SLOPE # 1"/ FT.11.24" DEEP WATERING TUBE 4"ØPERFORATED PIPE WITH 3"Ø GRATE,LOCATION, UPHILL SIDE.12.ADJACENT SIDEWALK13.21 GM. PLANT TABS PER SPECS. PLACEIN DIRECT CONTACT W/ ROOT BALL.1.5 X CONTAINERDEPTH, FOR 1GAL. PLANTS 1"LESS THANCONTAINERDEPTH FOR 5 & 15GAL. PLANTS.2X CONTAINER WIDTH ATBOTTOM OF PIT3"MAX.6"WIDTH PER PLANSINSTALL LANDSCAPE FABRIC WHERE CRUSHEDROCK IS USED AS GROUNDCOVER INSTEAD OFMULCH1.FINISH GRADE.2.2" + BERM FORWATERING BASIN.3.TOP OF ROOTBALL 1"ABOVE SURROUNDINGGRADE.4.SHRUB, PER PLANS.5.21 GM. PLANT TABS, PERSPECS. PLACE IN DIRECTCONTACT W/ ROOTBALL.1 PER 1-GAL 2 PER 5-GAL6.BACKFILL MIX: 1/3NITROLIZED SHAVINGS,2/3 NATIVE SOILS, PLUSCORRECTIVES PERPLANTING NOTES.APPLY SUPERTHRIVE ™WITHIN 2 HOURS OFPLANTING PER NOTES.7.NATIVE ORUNDISTURBED SOILS.1.MIRAFI MSCAPE LANDSCAPEFABRIC2.90% COMPACTED SOIL3.ADJACENT PAVING, PERPLAN4.PLACE LARGER ROCKS ATSTREAM EDGES5.4"-8" Ø ARIZONA COBBLE6.NO LANDSCAPE FABRICSHALL BE VISIBLE, ADD ALAYER OF 1" Ø COBBLE TOFILL IN WHERE REQUIRED7.PLACE LARGER ROCKS ATSTREAM EDGES8.DG OR CRUSHED ROCK PERPLAN
100
111
110
WOMEN
MEN
DINING
WORKSTATION
103
108109
19'-6 1/2"20'-5 1/2"17'-0"52'-8"40'-0"71'-8"
15'-2"
2'-4 3/4"
7'-0 1/4"8'-8 3/4"20'-0"3'-4"14'-8"2'-0"19'-0 1/4"22'-8 3/4"12'-8 1/2"4'-4"2'-6"9'-0"9'-5 1/4"6 3/4"9'-5 1/4"74'-0"
2'-0"
4'-1"
21'-8"
1
3
3
4
4
5
6
7
10
12A 12B
13
15
16
17 24
24 21
23
19
112
3'-0 1/4"
6'-4" R.O.
2'-4"
6"
PUBLIC
171'-6"EQ.EQ.
4'-10 3/4"5'-8 3/4"4'-3"7'-5 1/4"6 5 11'-5"8'-4 1/4"2 3/4"3'-3"4'-3 1/2"
2'-4 3/4"
2'-6 3/4"
11
EQ.EQ.
2 3/4"
9
27'-1"8'-11 3/4"
1
±11'-1 1/2" R.O.±11'-1 1/2" R.O.±18'-0" R.O.
4
27
4
4
7'-2 3/4"15'-8"10'-11"104
KITCHEN
COOLER
WALK IN
FREEZER
WALK IN
UTILITY
TYP.
TYP.
TYP.
TYP.
TYP.
DRY STORAGE
SEE STRUCTURAL FOR
CONCRETE CURB, BELOW
2 8
5
106
102
SERVICE 5'-2 1/2"5'-6 1/2"3'-6 1/4"7'-6 3/4"2'-7 1/4"
25
20
11'-5"
8'-5 3/4"
3'-0"
CLEAR
OPENING
EMPLOYEE
107
3'-0 1/4"
CLEAR, HOLD
3'-0 1/2"3'-2"7'-0"
6'-8 1/2"
22
6'-3 3/4"
5'-11"2'-2"
101
105
GALLEY/PREP 2'-10"10'-11"4'-7"6 3/4"3'-7 1/4"9'-0"
23
1818
ALL REPORTS, PLANS AND
DOCUMENTS PREPARED BY MARKS
ARCHITECTS SHALL REMAIN THE
PROPERTY OF MARKS ARCHITECTS
AND IS INTENDED FOR USE FOR THIS
SPECIFIC PROJECT ONLY.
marks architects 2022
PLANNING SUBMITTAL 01.14.22
MK10B
ADDRESS:
MK TYPE:
JIB #:
MK10B
5497
ⒸSGOOTAESTRENEWAL DATE
CF FLAI12-30-2023 NRAIRKRBAC-31482
AEI M
ALICENS E D ARCH
I
TECTL
HWY 74 NS
EL TORO CUT OFF,
LAKE ELSINORE CA,
92532
PROVIDE THE FOLLOWING MOISTURE RESISTANT MATERIALS.
SEE SPECIFICATIONS FOR OTHER DETAILS
HIGH MOISTURE REGIONS
1.
2.GEORGIA PACIFIC DENSARMOR PLUS INTERIOR FIREGUARD TYPE 'X' GLASS MAT
GYPSUM BOARD IN LIEU OF PAPER FACED GYPSUM BOARD.
JOHNS MANVILLE MR FACED INSULATION AT EXTERIOR STUD WALLS IN LIEU OF
KRAFT FACED INSULATION. POSITION INSULATION WITH THE MR FACED SIDE
LOCATED ON THE EXTERIOR FACE OF STUD (ADJACENT TO THE EXTERIOR PLYWOOD
SHEATHING)
3.GEORGIA PACIFIC DENS SHIELD FIREGUARD TILE GUARD TYPE 'X' ACRYLIC COATED
GLASS MAT GYPSUM BOARD IN LIEU OF CEMENTITIOUS BACKER BOARD (C.B.B.)
D.TYPICAL INTERIOR WALLS.
KEY NOTES
FLOOR PLAN
A1.0
1/4" = 1'-0"
1
2
ELECTRICAL PANELS, SEE ELECTRICAL DRAWINGS.
ELECTRICAL METER, SEE EXTERIOR ELEV. AND ELECTRICAL DRAWINGS.
WALK-IN FREEZER AND COOLER, SEE KITCHEN DRAWINGS.
LINE OF FOOD SERVICE EQUIPMENT, SEE KITCHEN DRAWINGS.
GAS METER, SEE PLUMBING DRAWINGS.
LINE OF CONCRETE CURB, TYP.
3
4
5
6
7
8
9
10
11
13
15
16
17 LINE OF CANOPY, TYP.
18
19
20
21
6" BLOCK OUT AT THIS LOCATION FOR LIGHTING TIME CLOCK, SEE
ELECTRICAL DRAWINGS.
22GREASE TANK / BULK OIL SYSTEM BOX, SEE KITCHEN & PLUMBING
DRAWINGS.
12
R-19 BATT INSULATION IN ALL EXT. WALLS AND SOUND INSULATION IN ALL
RESTROOM AND WORKSTATION WALLS.
LANDING BEGINNING ELEV. 0'-0" TO SLOPE MAX 2% AWAY FROM BUILDING.
SEE SITE PLANS.
LINE OF BRANDING PANELS, ABOVE.
IRRIGATION CONTROLLER IN TAMPERPROOF ENCLOSURE,
SEE LANDSCAPE AND ELECTRICAL DRAWINGS.
C02 FILL BOX, SEE EXTERIOR ELEVATIONS.
LADDER TO ROOF.
BARRIER POST, TYP., SEE SITE DETAILS.
MOP SINK.
ROOF DRAINS . SEE SITE PLAN FOR CONTINUATION.
COUNTER AT DRIVE-THRU CASHIER WINDOW. SEE GENERAL NOTE 8
THIS SHEET.
FOAM SEAL TOP OF CHASE AFTER ALL SERVICES ARE COMPLETED.
12.
2.
6.
11.
10.
8.
7.
1.
14.
15.
16.
17.
13.
9.
18.
3.
5.
4.PROVIDE 2x SOLID BLOCKING IN WALLS AS REQUIRED FOR REINFORCEMENT OF ALL
GRAB BARS, RESTROOM FIXTURES, PLUMBING LINES, WALL BUMPERS AND MILLWORK
ATTACHMENT, ETC.
ALL DIMENSIONS SHOWN TO FACE OF EXTERIOR WALLS ARE FACE OF STUD, ALL
DIMENSIONS SHOWN TO INTERIOR WALLS ARE TO CENTERLINE OF STUD, OR FACE OF
FINISH GYPSUM BOARD OR PLYWOOD.
ALL EXTERIOR WALLS SHALL BE 2x6 WOOD STUDS AT 16" O.C. W/ 5/8" WATER
RESISTANT GYPSUM BOARD ON THE INTERIOR FACE, U.O.N.
ALL INTERIOR WALLS SHALL BE 2x4 WOOD STUDS AT 24" O.C. W/ 5/8" WATER
RESISTANT GYPSUM BOARD ON BOTH SIDES, U.O.N.
ALL EXTERIOR DOORS SHALL BE WEATHERSTRIPPED. ALL EXTERIOR JOINTS AROUND
DOOR FRAMES & WINDOWS & AT ALL PENETRATIONS THROUGH BUILDING ENVELOPE
SHALL BE SEALED USING SEALANT & CAULKING. ADDITIONALLY, FOAM INSULATION
SHALL BE PROVIDED IN & AROUND ALL WINDOW AND/OR DOOR FRAMES WHERE
METAL MEETS WOOD FRAMING PLUS ALL EXTERIOR WALL OPENINGS/PENETRATIONS.
ALL GLAZING WITHIN DOORS AND OPERABLE WINDOW, AND ALL GLAZING ADJACENT
TO DOORS SHALL BE TEMPERED AS REQUIRED BY CURRENT BUILDING CODE.
POST MAX SIZE OCCUPANCY LOAD SIGN IN CONSPICUOUS PLACE NEAR MAIN EXITS
AT 6'-10" A.F.F. CAULK AROUND ALL SIDES. "MAXIMUM SEATING CAPACITY - 46. FOR
SEAT COUNT, SEE "BUILDING DATA" ON SHEET TS1.0.
ALL FINISH SURFACES SHALL HAVE A FLAME SPREAD CLASSIFICATION OF CLASS C
OR HIGHER (FLAME SPREAD INDEX 76 THROUGH 200 & A SMOKE DENSITY RATING
OF 450).
ALL EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT ANY SPECIAL
KNOWLEDGE OR EFFORT OR THE USE OF A KEY.
FOR EXTERIOR WALL TREATMENT, SEE EXTERIOR ELEVATIONS.
ALL DRAPES, CURTAINS & DECORATIVE MATERIAL PROVIDED AND/OR INSTALLED BY
THE GENERAL CONTRACTOR SHALL BE MADE FROM NONFLAMMABLE MATERIALS OR
TREATED WITH FLAME RETARDANT AS REQUIRED BY THE LOCAL FIRE MARSHAL.
OWNER SHALL PROVIDE PORTABLE FIRE EXTINGUISHERS PER LOCAL FIRE MARSHAL.
GENERAL CONTRACTOR TO INSTALL.
BUILDING ADDRESS NUMBERS SHALL BE A MINIMUM 12" HIGH AND BE OF
CONTRASTING COLORS.
ANY TIME THE BUILDING IS OCCUPIED, THE MEANS OF EGRESS SHALL BE
ILLUMINATED AT AN INTENSITY OF NOT LESS THAN 1 FOOT-CANDLE AT THE
FLOOR LEVEL. SEE ELECTRICAL DRAWINGS.
PROVIDE EXIT SIGNS FOR EGRESS IDENTIFICATION. SEE ELECTRICAL
DRAWINGS.
PROVIDE APPROVED EGRESS ILLUMINATION AND ILLUMINATED EXIT SIGNS.
SEE ELECTRICAL DRAWINGS.
PROVIDE APPROVED PANIC HARDWARE ON EXIT DOORS.
CONTRACTOR TO PROVIDE BORIC ACID TERMITE PROTECTION IN ALL WALLS.
20.
19.GENERAL CONTRACTOR SHALL COORDINATE THEIR WORK WITH THE
WORK OF THE FOOD SERVICE EQUIPMENT CONTRACTOR.
FOR ITEMS FURNISHED BY OTHERS & INSTALLED BY GENERAL
CONTRACTOR SEE KITCHEN AND INTERIOR DRAWINGS.
21.CONSULT CONSTRUCTION MANAGER FOR REQUIREMENTS FOR AIR CURTAINS
AT DRIVE THRU AND CASHIER WINDOWS AND AT DINING ENTRIES. PROVIDE
DOOR SWITCHES AS NECESSARY.
22.EXIT AISLES SHALL MEET ALL APPLICABLE CODES.
GENERAL NOTES
A.
5 1/2" STL. STUDS AT 16" O.C. PER STRUCTURAL DRAWINGS, U.N.O.. USE
NON-COMBUSTIBLE BLOCKING AT THIS LOCATION.
INDICATES WALLS THAT SHALL BE:
B.
5/8" WATER RESISTANT GYPSUM BOARD.
INDICATES INTERIOR WALL FACE W/ 5/8" PLYWOOD IN LIEU OF
INDICATES INTERIOR WALL W/ 1/4" GYPSUM BOARD OVER 5/8"
PLYWOOD.
C.
2x6 WOOD STUDS AT 16" O.C. U.N.O.
INDICATES INTERIOR WALLS THAT SHALL BE
23
INSTALL 5/8" GYPSUM BOARD OVER STEEL STUDS. DO NOT INSTALL F.R.P.
BEHIND HOODS. SEE KITCHEN DRAWINGS FOR STAINLESS STEEL FINISH.
24
14
A.
20 ga 5 1/2" STL. STUDS AT 16" O.C. U.N.O. USE NON-COMBUSTIBLE BLOCKING AT
THIS LOCATION. (WALL OCCURS ON SPLIT COOKLINE ONLY)
INDICATES WALLS THAT SHALL BE:
NORTH
E.PROVIDE TILE BACKER BOARD AT ALL WALL TILE.
PROVIDE NON-COMBUSTIBLE BLOCKING IN WALL FOR KITCHEN EQUIPMENT.
SEE GENERAL NOTE 4 THIS SHEET FOR ADDITINAL INFORMATION.
INTERIOR STOREFRONT WINDOW. SEE IINTERIOR DESIGN DRAWINGS FOR
ADDITIONAL INFORMATION.
BATT INSULATION IN NON-COMBUSTIBLE WALL AREA SHALL BE UN-FACED
NON-COMBUSTIBLE INSULATION.
FLOOR PLAN - JACK IN THE BOX
1/4" = 1'-0"
1
PLANNING 1ST CORR. 06.28.221
5'-6"
0'-0"
TOP OF SLAB
20'-0"
TOP OF UPPER PARAPET
9'-6"
BOT.OF CANOPY
7'-6"
TOP OF OPNG.
2'-8"
WINDOW SILL HEIGHT
@ DRIVE THRU1'-0"C.L. OF FIXTURE ARM
19'-2"
TOP OF LOWER PARAPET
22'-8"
TOP OF PARAPET
24
-
07
-
TYP.
07
-TYP.
7'-6"C.L. OF R.J.C.L. OF MARQUEE3'-9"3'-9"
3'-9"7'-6"3'-9"
09
F
2'-7"2'-10"8'-7"8'-7"C.L. OF R.J.
T.O. OF C.J.
7'-6"1'-3"6'-6"6'-6"6'-6"
F.G.
7'-6"C.L. OF R.J.3'-9"7'-6"3'-9"
7'-6"1'-3"7'-6"C.L. OF R.J.3'-9"7'-6"3'-9"
7'-6"C.J.3'-9"C.L. OF MARQUEE01
B
CORRUGATED WALL PANELS, OWNER PROVIDED, OWNER INSTALLED
EQ.EQ.
F.G.F.G.
T.G.
F.G.
T.G.
T.G.
LAKE ELSINORE JACK
0'-0"
TOP OF SLAB
9'-6"
BOT.OF CANOPY
8'-0"
TOP OF OPNG.
2'-4"
BOTTOM OF OPNG.
9'-6"
BOT.OF CANOPY
AND BAND
0'-0"
TOP OF SLAB
12'-8"
TOP OF OPNG.
16'-0"
TOP OF PARAPET
1'-6"
TOP OF CONC. CURB
22'-8"
TOP OF PARAPET
5'-6"
3'-4"16'-8"C.L. OF C.J.2'-7"EQ.EQ.
EQ.
6'-6"6'-6"6'-6"
EQ.
CORRUGATED WALL PANELS, OWNER PROVIDED, OWNER INSTALLED
92532
2'-5"4'-6"
UNDERSIDE OF COPING
UNDERSIDE OF COPING
4'-6"4'-6"2'-5"2'-6"4'-6"2'-6"
CORRUGATED WALL PANELS DO
NOT OVERLAP AT CORNERS
CORRUGATED WALL
PANELS DO NOT OVERLAP
AT CORNERSC.J.C.J.C.J.T.G.T.G.
CENTER LIGHT ON
CENTER OF WINDOW
BANDING
EQ.EQ.
NORTH E L E V A T I O N
WEST E L E V A T I O N
ALL REPORTS, PLANS AND
DOCUMENTS PREPARED BY MARKS
ARCHITECTS SHALL REMAIN THE
PROPERTY OF MARKS ARCHITECTS
AND IS INTENDED FOR USE FOR THIS
SPECIFIC PROJECT ONLY.
marks architects 2022
PLANNING SUBMITTAL 01.14.22
MK10B
ADDRESS:
MK TYPE:
JIB #:
MK10B
5497
ⒸSGOOTAESTRENEWAL DATE
CF FLAI12-30-2023 NRAIRKRBAC-31482
AEI M
ALICENS E D ARCH
ITECTL
HWY 74 NS
EL TORO CUT OFF,
LAKE ELSINORE CA,
92532
EXTERIOR
ELEVATIONS
A1.1
INTERNALLY ILLUMINATED SIGNAGE (O.F.O.I., NOT A PART OF THIS PERMIT)
STONE VENNER
ALUMINUM STOREFRONT SYSTEM (SEE SPECS FOR MORE INFORMATION)
EXTERIOR CEMENT PLASTER- SAND FLOAT FINISH
ALUMINUM COPING. COLOR TO BE FACTORY APPLIED TO BE COLOR LISTED OR BE EQUIVALENT MATCH.11
CO2 FILL BOX METAL COVER
07
12
03
COLOR
MATERIAL/FINISH
01
06
10
04
02
MATERIAL/FINISH:
01
A
MAIN ELECTRICAL SERVICE08
GREASE TANK / BULK OIL SYSTEM BOX
1" CLEAR INSULATED GLASS
1" CLEAR INSULATED GLASS
EXTERIOR FINISH SCHEDULE
ANTI-GRAFFITI FILM
COLOR:
SHERWIN WILLIAMS: SW 6991
A
B
W/ SOLARBAN 60 COATING
16
17
WALL MOUNTED LIGHT FIXTURE, SEE DETAIL 16/A9.3 FOR FIXTURE ATTACHMENT.
SHERWIN WILLIAMS ACRYLIC COATING
INTEGRAL COLOR
(SEE SPECIFICATIONS)
SERVING GRAY
4.
1.
2.
3.
ALL SIGNAGE IS UNDER SEPARATE SUBMITTAL AND PERMIT (N.I.C.).
GENERAL NOTES:
C.J. = PLASTER CONTROL JOINT
SHERWIN WILLIAMS: SW 2827
EXTERIOR INSULATION FINISHING SYSTEM (EIFS)
AS ALTERNATE, CONTRACTOR TO SUBSTITUTE EIFS IN LIEU OF
EXTERIOR CEMENT PLASTER
15 FEATURE WINDOW POP OUT W/ ALUMINUM BREAK METAL PANELS
1" CLEAR INSULATED GLASS W/
SOLARBAN 70XL COATING
LOCKABLE, IRRIGATION CONTROL PANEL09
ALL PLASTER ACCESSORIES, FLASHING ETC. SHALL BE PAINTED TO MATCH ADJACENT SURFACES.(U.O.N.)
ALL EXTERIOR WALL OPENINGS FOR RECEPTACLES, HOSE BIBBS, ETC. SHALL BE SEALED. SEE FLOOR PLAN,
GENERAL NOTES, AND SPECIFICATIONS FOR ADDITIONAL NOTES.
5.R.J. = 3/4" PLASTER REVEAL JOINT
6.
14 MOUNT LIGHTING FIXTURE WITHIN CANOPY
AWNING/CANOPY & SUPPORTS (O.F.O.I) OF-EQ23 OF-EQ24
13
PLASTER CONTROL JOINT
ALL OUTSIDE CORNERS WITH CROSSVILLE SPEAKEASY TO GET
DRIVE THRU/ CASHIER WINDOW
OF-EQ25
ILLUMINATED ADDRESS WITH 12" HIGH LETTERS (AS REQUIRED PER LOCAL JURISDICTION)05
C STANDARD STOREFRONT: CLEAR ANODIZED
D WHITE TEXT ON WHITE BACKGROUND
E RAL-7039 QUARTZ GREY
F COLOR /FINISH TO MATCH ADJACENT SURFACE
TOTAL FRONTAGE - 74'-0" ON HWY 74
40'-0 ON EL TORO CUT OFF
74'-0" ON FRONTAGE ROAD
188'-0" FRONTAGE
SIGNAGE PROVIDED: (3) SIGNS 25 S.F. E.A
1
188'-0" OF SIGNAGE ALLOWET
TOTAL : 75'-0" S.F. PROVIDED
SIGNAGE CALCULATION
PLANNING 1ST CORR. 06.28.221
PLANNING 2ND CORR. 10.31.222
2
T.G.T.G.
T.G.T.G.
20'-0"
TOP OF UPPER PARAPET
0'-0"
TOP OF SLAB
9'-6"
BOT.OF TRANSOM
12'-8"
TOP OF OPNG.
16'-0"
TOP OF PARAPET 1'-0"C.L. OF FIXTURE ARM
0'-0"
TOP OF SLAB
16'-0"
TOP OF PARAPET
22'-6"
TOP OF PARAPET
20'-0"
TOP OF UPPER PARAPET
1'-0"C.L. OF FIXTURE ARM
19'-2"
TOP OF LOWER PARAPET
15
F
03
F
07
-
9'-6"
BOT. OF BAND/CANOPY
07
-
EQ.C.L. OF C.J.C.L. OF C.J.4'-3"4'-3"
℄C.L. OF C.J.10 1/8"09
F EQ.EQ.C.L. OF C.J.EQ.EQ.C.L. OF C.J.ALIGN W/ OPNG.ALIGN W/ OPNG.EQ.
EQ.EQ.C.L. OF C.J.2'-7"C.L. OF R.J.7'-6"1'-3"7'-6"C.L. OF R.J.3'-9"7'-6"3'-9"
7'-6"6'-6"6'-6"6'-6"
EQ.EQ.C.L. OF C.J.ALIGN W/ OPNG.2'-6"2'-10"8'-7"8'-7"C.L. OF R.J.
T.O. C.J.
7'-3 1/4"C.L. OF R.J.4'-10 5/8"5'-4 1/8"
GAS
METER C.J.1'-3"7'-6"
3'-9"7'-6"3'-9"
7'-6"
3'-9"7'-6"3'-9"
7'-6"C.L. OF R.J.06
D
07
-
TYP.
07
-
TYP.
CORRUGATED WALL PANELS, OWNER PROVIDED, OWNER INSTALLED
UNDERSIDE OF COPING C.J.C.J.C.J.PROVIDE ADDRESS
PLAQUE AT GAS AND
ELECTRIC METERS
(COORDINATE WITH JIB
PROJECT MANAGER)
07
-
TYP.4'-0"EQ.EQ.GAS METER09
F
SOUTH E L E V A T I O N
EAST E L E V A T I O N
ALL REPORTS, PLANS AND
DOCUMENTS PREPARED BY MARKS
ARCHITECTS SHALL REMAIN THE
PROPERTY OF MARKS ARCHITECTS
AND IS INTENDED FOR USE FOR THIS
SPECIFIC PROJECT ONLY.
marks architects 2022
PLANNING SUBMITTAL 01.14.22
MK10B
ADDRESS:
MK TYPE:
JIB #:
MK10B
5497
ⒸSGOOTAESTRENEWAL DATE
CF FLAI12-30-2023 NRAIRKRBAC-31482
AEI M
ALICENS E D ARCHI
TECTL
HWY 74 NS
EL TORO CUT OFF,
LAKE ELSINORE CA,
92532
EXTERIOR
ELEVATIONS
A1.2
INTERNALLY ILLUMINATED SIGNAGE (O.F.O.I., NOT A PART OF THIS PERMIT)
STONE VENNER
ALUMINUM STOREFRONT SYSTEM (SEE SPECS FOR MORE INFORMATION)
EXTERIOR CEMENT PLASTER- SAND FLOAT FINISH
ALUMINUM COPING. COLOR TO BE FACTORY APPLIED TO BE COLOR LISTED OR BE EQUIVALENT MATCH.11
CO2 FILL BOX METAL COVER
07
12
03
COLOR
MATERIAL/FINISH
01
06
10
04
02
MATERIAL/FINISH:
01
A
MAIN ELECTRICAL SERVICE08
GREASE TANK / BULK OIL SYSTEM BOX
1" CLEAR INSULATED GLASS
1" CLEAR INSULATED GLASS
EXTERIOR FINISH SCHEDULE
ANTI-GRAFFITI FILM
COLOR:
SHERWIN WILLIAMS: SW 6991
A
B
W/ SOLARBAN 60 COATING
16
17
WALL MOUNTED LIGHT FIXTURE, SEE DETAIL 16/A9.3 FOR FIXTURE ATTACHMENT.
SHERWIN WILLIAMS ACRYLIC COATING
INTEGRAL COLOR
(SEE SPECIFICATIONS)
SERVING GRAY
4.
1.
2.
3.
ALL SIGNAGE IS UNDER SEPARATE SUBMITTAL AND PERMIT (N.I.C.).
GENERAL NOTES:
C.J. = PLASTER CONTROL JOINT
SHERWIN WILLIAMS: SW 2827
EXTERIOR INSULATION FINISHING SYSTEM (EIFS)
AS ALTERNATE, CONTRACTOR TO SUBSTITUTE EIFS IN LIEU OF
EXTERIOR CEMENT PLASTER
15 FEATURE WINDOW POP OUT W/ ALUMINUM BREAK METAL PANELS
1" CLEAR INSULATED GLASS W/
SOLARBAN 70XL COATING
LOCKABLE, IRRIGATION CONTROL PANEL09
ALL PLASTER ACCESSORIES, FLASHING ETC. SHALL BE PAINTED TO MATCH ADJACENT SURFACES.(U.O.N.)
ALL EXTERIOR WALL OPENINGS FOR RECEPTACLES, HOSE BIBBS, ETC. SHALL BE SEALED. SEE FLOOR PLAN,
GENERAL NOTES, AND SPECIFICATIONS FOR ADDITIONAL NOTES.
5.R.J. = 3/4" PLASTER REVEAL JOINT
6.
14 MOUNT LIGHTING FIXTURE WITHIN CANOPY
AWNING/CANOPY & SUPPORTS (O.F.O.I) OF-EQ23 OF-EQ24
13
PLASTER CONTROL JOINT
ALL OUTSIDE CORNERS WITH CROSSVILLE SPEAKEASY TO GET
DRIVE THRU/ CASHIER WINDOW
OF-EQ25
ILLUMINATED ADDRESS WITH 12" HIGH LETTERS (AS REQUIRED PER LOCAL JURISDICTION)05
C STANDARD STOREFRONT: CLEAR ANODIZED
D WHITE TEXT ON WHITE BACKGROUND
E RAL-7039 QUARTZ GREY
F COLOR /FINISH TO MATCH ADJACENT SURFACE
2
TOTAL FRONTAGE - 74'-0" ON HWY 74
40'-0 ON EL TORO CUT OFF
74'-0" ON FRONTAGE ROAD
188'-0" FRONTAGE
SIGNAGE PROVIDED: (3) SIGNS 25 S.F. E.A
1
188'-0" OF SIGNAGE ALLOWET
TOTAL : 75'-0" S.F. PROVIDED
SIGNAGE CALCULATION
PLANNING 1ST CORR. 06.28.221
PLANNING 2ND CORR. 10.31.222
PARAPET BEYOND
ROOF TOP UNITS PER MECHANICAL
DRAWINGS, MOUNT ON LEVEL
CURBS, PLATFORMS, ETC.
CONC. SLAB, CURBS,
& FOOTINGS PER
STRUCT. DWGS.
KITCHEN
MENU
BOARD DINING
KICKER PER
STRUCTURAL
DRAWINGS
SLOPE 1/2"/FT.
HVAC DUCTWORK
SLOPE 1/2"/FT.
COOLER
WALK IN
FREEZER
WALK IN
PARAPET BEYOND ROOF TOP UNITS PER
MECHANICAL DRAWINGS,
MOUNT ON LEVEL CURBS,
PLATFORMS, ETC.
ROOF TOP CONDENSING UNIT
PER MECHANICAL DRAWINGS,
MOUNT ON LEVEL CURBS,
PLATFORMS, ETC.
CONC. SLAB, CURBS, & FOOTINGS
PER STRUCT. DWGS.
KITCHENDRY STORAGE
SCUPPER THRU PARAPET WALL
BEYOND, SEE DETAIL 8/A9.0
EMPLOYEEGALLEY/PREP
ALL REPORTS, PLANS AND
DOCUMENTS PREPARED BY MARKS
ARCHITECTS SHALL REMAIN THE
PROPERTY OF MARKS ARCHITECTS
AND IS INTENDED FOR USE FOR THIS
SPECIFIC PROJECT ONLY.
marks architects 2022
PLANNING SUBMITTAL 01.14.22
MK10B
ADDRESS:
MK TYPE:
JIB #:
MK10B
5497
ⒸSGOOTAESTRENEWAL DATE
CF FLAI12-30-2023 NRAIRKRBAC-31482
AEI M
ALICENS E D ARCH
ITECTL
HWY 74 NS
EL TORO CUT OFF,
LAKE ELSINORE CA,
92532
BUILDING CROSS SECTION2
BUILDING
SECTIONS
A1.3
1 BUILDING LONGITUDINAL SECTION
1
PLANNING 1ST CORR. 06.28.221
PLANNING 2ND CORR. 10.31.222
2
KITCHEN
WALK IN COOLER
RESTROOM
DRIVE
THRU
3'-0"
3'-0"6'-2 1/2"33'-4 3/4"3'-8 1/2"5'-3 1/2"7'-3 1/4"13'-7 1/2"1
6
5
3'-2"2'-11 1/2"7'-3 1/4"3'-2"3'-2 1/4"34'-9 3/4"7'-10"1'-7 3/4"2'-10 3/4"7'-10"2'-10 3/4"4 1/4"4 1/4"1'-10 1/4"10'-7 1/2"1'-10 1/4"4 1/4"1'-7 3/4"7'-10"34'-9 3/4"4 1/4"
1'-10 1/4"
1 3/4"
7'-10"
1 3/4"
1'-10 1/4"21'-4 1/4"1'-10 1/4"8'-1 1/2"1'-10 1/4"1'-10 1/4"10'-7 1/2"1'-10 1/4"1'-10 1/4"8'-1 1/2"1'-10 1/4"21'-4 1/4"1'-10 1/4"8'-1 1/2"1'-10 1/4"
9
9
2
2
2
7
8
10
3
33
3 3 3
33
4
4
ALL REPORTS, PLANS AND
DOCUMENTS PREPARED BY MARKS
ARCHITECTS SHALL REMAIN THE
PROPERTY OF MARKS ARCHITECTS
AND IS INTENDED FOR USE FOR THIS
SPECIFIC PROJECT ONLY.
marks architects 2022
PLANNING SUBMITTAL 01.14.22
MK10B
ADDRESS:
MK TYPE:
JIB #:
MK10B
5497
ⒸSGOOTAESTRENEWAL DATE
CF FLAI12-30-2023 NRAIRKRBAC-31482
AEI M
ALICENS E D ARCH
I
TECTL
HWY 74 NS
EL TORO CUT OFF,
LAKE ELSINORE CA,
92532
PROVIDE THE FOLLOWING MOISTURE RESISTANT MATERIALS.
SEE SPECIFICATIONS FOR OTHER DETAILS
HIGH MOISTURE REGIONS
1.
2.GEORGIA PACIFIC DENSARMOR PLUS INTERIOR FIREGUARD TYPE 'X' GLASS MAT
GYPSUM BOARD IN LIEU OF PAPER FACED GYPSUM BOARD.
JOHNS MANVILLE MR FACED INSULATION AT EXTERIOR STUD WALLS IN LIEU OF
KRAFT FACED INSULATION. POSITION INSULATION WITH THE MR FACED SIDE
LOCATED ON THE EXTERIOR FACE OF STUD (ADJACENT TO THE EXTERIOR PLYWOOD
SHEATHING)
3.GEORGIA PACIFIC DENS SHIELD FIREGUARD TILE GUARD TYPE 'X' ACRYLIC COATED
GLASS MAT GYPSUM BOARD IN LIEU OF CEMENTITIOUS BACKER BOARD (C.B.B.)
D.TYPICAL INTERIOR WALLS.
KEY NOTES
FLOOR PLAN
A2.0
3/8" = 1'-0"
1
2
ELECTRICAL METER, SEE EXTERIOR ELEV. AND ELECTRICAL DRAWINGS.
WALK-IN FREEZER AND COOLER, SEE KITCHEN DRAWINGS.
LINE OF FOOD SERVICE EQUIPMENT, SEE KITCHEN DRAWINGS.
GAS METER, SEE PLUMBING DRAWINGS.
LINE OF CONCRETE CURB, TYP.
3
4
5
6
7
8
9
10
LINE OF CANOPY, TYP.
BARRIER POST, TYP., SEE SITE DETAILS.
COUNTER AT DRIVE-THRU CASHIER WINDOW. SEE GENERAL NOTE 8
THIS SHEET.
12.
2.
6.
11.
10.
8.
7.
1.
14.
15.
16.
17.
13.
9.
18.
3.
5.
4.PROVIDE 2x SOLID BLOCKING IN WALLS AS REQUIRED FOR REINFORCEMENT OF ALL
GRAB BARS, RESTROOM FIXTURES, PLUMBING LINES, WALL BUMPERS AND MILLWORK
ATTACHMENT, ETC.
ALL DIMENSIONS SHOWN TO FACE OF EXTERIOR WALLS ARE FACE OF STUD, ALL
DIMENSIONS SHOWN TO INTERIOR WALLS ARE TO CENTERLINE OF STUD, OR FACE OF
FINISH GYPSUM BOARD OR PLYWOOD.
ALL EXTERIOR WALLS SHALL BE 2x6 WOOD STUDS AT 16" O.C. W/ 5/8" WATER
RESISTANT GYPSUM BOARD ON THE INTERIOR FACE, U.O.N.
ALL INTERIOR WALLS SHALL BE 2x4 WOOD STUDS AT 24" O.C. W/ 5/8" WATER
RESISTANT GYPSUM BOARD ON BOTH SIDES, U.O.N.
ALL EXTERIOR DOORS SHALL BE WEATHERSTRIPPED. ALL EXTERIOR JOINTS AROUND
DOOR FRAMES & WINDOWS & AT ALL PENETRATIONS THROUGH BUILDING ENVELOPE
SHALL BE SEALED USING SEALANT & CAULKING. ADDITIONALLY, FOAM INSULATION
SHALL BE PROVIDED IN & AROUND ALL WINDOW AND/OR DOOR FRAMES WHERE
METAL MEETS WOOD FRAMING PLUS ALL EXTERIOR WALL OPENINGS/PENETRATIONS.
ALL GLAZING WITHIN DOORS AND OPERABLE WINDOW, AND ALL GLAZING ADJACENT
TO DOORS SHALL BE TEMPERED AS REQUIRED BY CURRENT BUILDING CODE.
POST MAX SIZE OCCUPANCY LOAD SIGN IN CONSPICUOUS PLACE NEAR MAIN EXITS
AT 6'-10" A.F.F. CAULK AROUND ALL SIDES. "MAXIMUM SEATING CAPACITY - 46. FOR
SEAT COUNT, SEE "BUILDING DATA" ON SHEET TS1.0.
ALL FINISH SURFACES SHALL HAVE A FLAME SPREAD CLASSIFICATION OF CLASS C
OR HIGHER (FLAME SPREAD INDEX 76 THROUGH 200 & A SMOKE DENSITY RATING
OF 450).
ALL EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT ANY SPECIAL
KNOWLEDGE OR EFFORT OR THE USE OF A KEY.
FOR EXTERIOR WALL TREATMENT, SEE EXTERIOR ELEVATIONS.
ALL DRAPES, CURTAINS & DECORATIVE MATERIAL PROVIDED AND/OR INSTALLED BY
THE GENERAL CONTRACTOR SHALL BE MADE FROM NONFLAMMABLE MATERIALS OR
TREATED WITH FLAME RETARDANT AS REQUIRED BY THE LOCAL FIRE MARSHAL.
OWNER SHALL PROVIDE PORTABLE FIRE EXTINGUISHERS PER LOCAL FIRE MARSHAL.
GENERAL CONTRACTOR TO INSTALL.
BUILDING ADDRESS NUMBERS SHALL BE A MINIMUM 12" HIGH AND BE OF
CONTRASTING COLORS.
ANY TIME THE BUILDING IS OCCUPIED, THE MEANS OF EGRESS SHALL BE
ILLUMINATED AT AN INTENSITY OF NOT LESS THAN 1 FOOT-CANDLE AT THE
FLOOR LEVEL. SEE ELECTRICAL DRAWINGS.
PROVIDE EXIT SIGNS FOR EGRESS IDENTIFICATION. SEE ELECTRICAL
DRAWINGS.
PROVIDE APPROVED EGRESS ILLUMINATION AND ILLUMINATED EXIT SIGNS.
SEE ELECTRICAL DRAWINGS.
PROVIDE APPROVED PANIC HARDWARE ON EXIT DOORS.
CONTRACTOR TO PROVIDE BORIC ACID TERMITE PROTECTION IN ALL WALLS.
20.
19.GENERAL CONTRACTOR SHALL COORDINATE THEIR WORK WITH THE
WORK OF THE FOOD SERVICE EQUIPMENT CONTRACTOR.
FOR ITEMS FURNISHED BY OTHERS & INSTALLED BY GENERAL
CONTRACTOR SEE KITCHEN AND INTERIOR DRAWINGS.
21.CONSULT CONSTRUCTION MANAGER FOR REQUIREMENTS FOR AIR CURTAINS
AT DRIVE THRU AND CASHIER WINDOWS AND AT DINING ENTRIES. PROVIDE
DOOR SWITCHES AS NECESSARY.
22.EXIT AISLES SHALL MEET ALL APPLICABLE CODES.
GENERAL NOTES
A.
5 1/2" STL. STUDS AT 16" O.C. PER STRUCTURAL DRAWINGS, U.N.O.. USE
NON-COMBUSTIBLE BLOCKING AT THIS LOCATION.
INDICATES WALLS THAT SHALL BE:
B.
5/8" WATER RESISTANT GYPSUM BOARD.
INDICATES INTERIOR WALL FACE W/ 5/8" PLYWOOD IN LIEU OF
INDICATES INTERIOR WALL W/ 1/4" GYPSUM BOARD OVER 5/8"
PLYWOOD.
C.
2x6 WOOD STUDS AT 16" O.C. U.N.O.
INDICATES INTERIOR WALLS THAT SHALL BE
A.
20 ga 5 1/2" STL. STUDS AT 16" O.C. U.N.O. USE NON-COMBUSTIBLE BLOCKING AT
THIS LOCATION. (WALL OCCURS ON SPLIT COOKLINE ONLY)
INDICATES WALLS THAT SHALL BE:
NORTH
E.PROVIDE TILE BACKER BOARD AT ALL WALL TILE.
COUNTER AT DRIVE-THRU PICK-UP WINDOW. SEE GENERAL NOTE
8 THIS SHEET.
R-19 BATT INSULATION IN ALL EXT. WALLS AND SOUND INSULATION IN ALL
RESTROOM AND WORKSTATION WALLS.
FLOOR PLAN - THE HUMAN BEAN
1/4" = 1'-0"
12'-10"
TOP OF PARAPET
FINISH FLOOR
19'-6"
TOP OF PARAPET
12'-0"
AWNINGS
0'-0"
FINISH FLOOR
0'-0"
16'-6"
TOP OF PARAPET
11
-
11
-
11
-
7
-
7
-
7
-
7
-
10
-
02
B
14
-
01
A
01
A
01
A
7
-
01
B
3'-0"
FINISH FLOOR
NORTH E L E V A T I O N
19'-6"
TOP OF PARAPET
12'-0"
AWNINGS
0'-0"
FINISH FLOOR
11
-
06
D
01
A
10
-
4
C
13
-
02
B
14
-
02
B
14
-
01
A
01
B
WEST E L E V A T I O N
19'-6"
TOP OF PARAPET
12'-0"
AWNINGS
0'-0"
FINISH FLOOR
11
-
7
-
7
-
02
B
14
-
02
B
14
-
01
A
10
-
01
B
EAST E L E V A T I O N
19'-6"
TOP OF PARAPET
0'-0"
FINISH FLOOR
12'-0"
AWNINGS
16'-6"
TOP OF PARAPET
0'-0"
FINISH FLOOR
12'-10"
TOP OF PARAPET
11
-
11
-
11
-
7
-
7
-
7
-
7
-
06
D
01
A
10
-
02
B
14
-
7
-
01
B
01
B
3'-0"
DRIVE THRU WINDOW
SOUTH E L E V A T I O N
ALL REPORTS, PLANS AND
DOCUMENTS PREPARED BY MARKS
ARCHITECTS SHALL REMAIN THE
PROPERTY OF MARKS ARCHITECTS
AND IS INTENDED FOR USE FOR THIS
SPECIFIC PROJECT ONLY.
marks architects 2022
PLANNING SUBMITTAL 01.14.22
MK10B
ADDRESS:
MK TYPE:
JIB #:
MK10B
5497
ⒸSGOOTAESTRENEWAL DATE
CF FLAI12-30-2023 NRAIRKRBAC-31482
AEI M
ALICENS E D ARCH
I
TECTL
HWY 74 NS
EL TORO CUT OFF,
LAKE ELSINORE CA,
92532
EXTERIOR
ELEVATIONS
A2.1
INTERNALLY ILLUMINATED SIGNAGE (O.F.O.I., NOT A PART OF THIS PERMIT)
STONE VENNER
ALUMINUM STOREFRONT SYSTEM (SEE SPECS FOR MORE INFORMATION)
EXTERIOR CEMENT PLASTER- SAND FLOAT FINISH
ALUMINUM COPING. COLOR TO BE FACTORY APPLIED TO BE COLOR LISTED OR BE EQUIVALENT MATCH.11
CO2 FILL BOX METAL COVER
07
12
03
COLOR
MATERIAL/FINISH
01
06
10
04
02
MATERIAL/FINISH:
01
A
MAIN ELECTRICAL SERVICE08
GREASE TANK / BULK OIL SYSTEM BOX
1" CLEAR INSULATED GLASS
1" CLEAR INSULATED GLASS
EXTERIOR FINISH SCHEDULE
ANTI-GRAFFITI FILM
COLOR:
SHERWIN WILLIAMS: SW 6991
A
B
W/ SOLARBAN 60 COATING
16
17
WALL MOUNTED LIGHT FIXTURE, SEE DETAIL 16/A9.3 FOR FIXTURE ATTACHMENT.
SHERWIN WILLIAMS ACRYLIC COATING
INTEGRAL COLOR
(SEE SPECIFICATIONS)
SERVING GRAY
4.
1.
2.
3.
ALL SIGNAGE IS UNDER SEPARATE SUBMITTAL AND PERMIT (N.I.C.).
GENERAL NOTES:
C.J. = PLASTER CONTROL JOINT
SHERWIN WILLIAMS: SW 2827
EXTERIOR INSULATION FINISHING SYSTEM (EIFS)
AS ALTERNATE, CONTRACTOR TO SUBSTITUTE EIFS IN LIEU OF
EXTERIOR CEMENT PLASTER
15 FEATURE WINDOW POP OUT W/ ALUMINUM BREAK METAL PANELS
1" CLEAR INSULATED GLASS W/
SOLARBAN 70XL COATING
LOCKABLE, IRRIGATION CONTROL PANEL09
ALL PLASTER ACCESSORIES, FLASHING ETC. SHALL BE PAINTED TO MATCH ADJACENT SURFACES.(U.O.N.)
ALL EXTERIOR WALL OPENINGS FOR RECEPTACLES, HOSE BIBBS, ETC. SHALL BE SEALED. SEE FLOOR PLAN,
GENERAL NOTES, AND SPECIFICATIONS FOR ADDITIONAL NOTES.
5.R.J. = 3/4" PLASTER REVEAL JOINT
6.
14 MOUNT LIGHTING FIXTURE WITHIN CANOPY
AWNING/CANOPY & SUPPORTS (O.F.O.I) OF-EQ23 OF-EQ24
13
PLASTER CONTROL JOINT
ALL OUTSIDE CORNERS WITH CROSSVILLE SPEAKEASY TO GET
DRIVE THRU/ CASHIER WINDOW
OF-EQ25
ILLUMINATED ADDRESS WITH 12" HIGH LETTERS (AS REQUIRED PER LOCAL JURISDICTION)05
C STANDARD STOREFRONT: CLEAR ANODIZED
D WHITE TEXT ON WHITE BACKGROUND
E RAL-7039 QUARTZ GREY
F COLOR /FINISH TO MATCH ADJACENT SURFACE
1
1
TOTAL FRONTAGE - 34'-0" ON HWY 74
13'-0" ON EL TORO CUT OFF
34'-0" ON FRONTAGE ROAD
81'-0" FRONTAGE
SIGNAGE PROVIDED: (3) SIGNS 27 S.F. E.A
1
81'-0" OF SIGNAGE ALLOWET
TOTAL : 81'-0" S.F. PROVIDED
SIGNAGE CALCULATION
PLANNING 1ST CORR. 06.28.221
PLANNING 2ND CORR. 10.31.222
2
T.G.T.G.
T.G.T.G.
GAS METER
JACK IN THE BOX ELEVATION
THE HUMAN BEAN ELEVATION
ALL REPORTS, PLANS AND
DOCUMENTS PREPARED BY MARKS
ARCHITECTS SHALL REMAIN THE
PROPERTY OF MARKS ARCHITECTS
AND IS INTENDED FOR USE FOR THIS
SPECIFIC PROJECT ONLY.
marks architects 2022
PLANNING SUBMITTAL 01.14.22
MK10B
ADDRESS:
MK TYPE:
JIB #:
MK10B
5497
ⒸSGOOTAESTRENEWAL DATE
CF FLAI12-30-2023 NRAIRKRBAC-31482
AEI M
ALICENS E D ARCH
ITECTL
HWY 74 NS
EL TORO CUT OFF,
LAKE ELSINORE CA,
92532
COLORS AND
MATERIAL
A3.0
MFR:SHERWIN WILLIAMS
COLOR: SW 7016
MINDFUL GRAY
MFR:SHERWIN WILLIAMS
COLOR: SW 6321
RED BAY
(D.T. TOWER)
MFR:SHERWIN WILLIAMS
COLOR: SW 7020
BLACK FOX
1 2
8" PORCELAIN WALL TILE
CROSSVILLE SPEAKEEASY
AV283, SWEET GEORGIA
BROWN WITH SAND
BEIGE H148 GROUT
4
CORRUGATED METAL
PANEL
5
3
1
5
4
3
2
MFR:SHERWIN WILLIAMS
COLOR: SW 7016
MINDFUL GRAY
MFR:SHERWIN WILLIAMS
COLOR: SW 6991
BLACK MAGIC
1 2
STONE VENNER
4
3
MFR:SHERWIN WILLIAMS
COLOR: SW 7662
EVENING SHADOW
1
2
34
1
1 PLANNING 1ST CORR. 06.23.22