Loading...
HomeMy WebLinkAboutGERANIUM DRIVE 36434_15-00001278 CITY OF LAI�E LSI AOI�E BUILDING & SAFETY( DREAM EXT RE M E TM 130 South Main Street Lake Elsinore Ca. 92530 PERMIT PERMIT NO: 15=00001278 DATE: 5/27/15 JOB ADDRESS . . . . . 36434 GERANIUM DRIVE LT194 DESCRIPTION OF WORK ELECTRICAL OWNER CONTRACTOR PARDEE SOLARCITY CORP. 35050 CANYON HILLS RD 3055 CLEARVIEW WAY LAKE ELSINORE CA 92532 SAN MATEO, CA 94402 650-638-1028 LIC EXP 0/00/00 A.P.# . . . 358-372-005 9 SQUARE FOOTAGE 0 OCCUPANCY . . . . GARAGE SQ FT 0 CONSTRUCTION FIRE SPRNKLR . VALUATION 15, 000. ZONE . . . . . . R-1 BUILDING PERMIT QTY UNIT CHG ITEM CHARGE BASE FEE 63 . 00 13 . 00 X 12 . 5000 VALUATION 162 . 50 ELECTRICAL PERMIT QTY UNIT CHG ITEM CHARGE BASE FEE 30 . 00 1 . 00 X 16 . 2500 MISC. WHERE NO OTHER FEE 16 . 25 FEE SUMMARY CHARGES PAID DUE PERMIT FEES BUILDING PERMIT 225 . 50 . 00 225 . 50 ELECTRICAL PERMIT 46 . 25 . 00 46 .25 OTHER FEES PROF.DEV.FEE 2 TRADES 10 . 00 . 00 10 . 00 PLANNING REVIEW FEE 45 . 10 45 . 10 . 00 PLAN RETENTION FEE 1 . 50 . 00 1 . 50 SEISMIC GROUP R 1. 95 . 00 1 . 95 PLAN CHECK FEES 169 . 13 169 . 13 . 00 TOTAL 499 .43 214 . 23 285 . 20 SPECIAL NOTES &CONDITIONS RESIDENTIAL ROOF MOUNT opep C.oUff ERz TI+RR`_ LF Lrawer Date S'r0/1; �4 � Receipt. no: h 61G0 41; BUILDING TERMIT L00 $285.20 183O35 -s2 E Q.53 UG Ui��i CARD t.���_ Trans date: 5/28/15 Time: 0-46:15 City of Lake Elsinore Please read and initial Building Safety Division 1.I am Licensed under the provisions of Business and professional Code Section 7000 et seq.and my license is in full force. Post in conspicuous place 2.I,as owner of the property,or my employees w/wages as their sole compensation will do the work on the job and the structure is not intended or offered for sale. -�°�-3.I,as owner of the property,am exclusively contracting with licensed contractors to construct the You must furnish PERMIT NUMBER and the deject. JOB ADDRESS for each respective inspection: Y 4.11111 have a certificate of consent to selfinsure or a certificate of Workers Compensation Insurance Approved plans must be on job or a certified copy thereof at all times: 5.I shall not employ any person in any manner so as to become subject to Workers Compensation Laws in the performance of the work for which this permit is issued. Note:If you should become subject to Workers Compensation after making this certification, Code Approvals Date Inspector you must forthwith comply with such provisions or this permit shall be deemed revoked. ELO 1 Temporary Electric Service PLO1 Soil Pipe Underground EL02 Electric Conduit Underground BPO1 Footings BP02 Steel Reinforcement BP03 Grout BP04 Slab Grade PLO Underground Water Pipe SSO1 Rough Septic System SWO1 On Site Sewer BP05 Floor Joists BP06 Floor Sheathing BP07 Roof Framing BP08 I Roof Sheathing BP09 Shear Wall&Pre-Lath PL03 Rough Plumbing EL03 Rough Electric Conduit EL04 Rough Electric Wiring EL05 Rough Electric/ T-Bar ME01 Rough Mechanical ME02 Ducts,Ventilating PL04 Rough Gas Pipe/Test PL02 Roof Drains BP 10 Framing&Flashing BP 12 Insulation BP 13 Drywall Nailing BP II Lathing&Siding PL99 *Final Plumbing EL99 *Final Electrical ME99 *Final Mechanical BP99 *Final Building *Final Signatures are Certificate of Occupancy for Single Family Residence Code Pool&Spa Approvals Date Inspector, OTHER DIVISION RELEASES SPO 1 Electric Conduit UG Department Approval required prior to the SP02 UG Gas Piping building being released by the City SP03 Pool Steel Rein./Forms •Date Inspector SP04 Pool Plmb./Pressure Test Fire SP05 Pre-Gunite Approval EVMWD SP06 Rough Pool Electric Finance SP07 Pool Fence/Gates/Alarms Engineering SP08 Pre-Plaster Approval TUMF SP99 Final Pool/Spa Planning/Landscape I' CITY C) F %`� } L.A. K- E ACT P;F M F 130 South Main Street D R- E A M i _ APPLI ' �ION "7 Q` .�" PPLfCATIO � �O AP LICATIO EIVEO i BUILDING PEjzMTT DATE �� VALUATION CALCULATIONS BUILDING AD•R ss 1 �orrP� SF TRACT BLOCK/ AGE ``7 1st FLOOR SF NA 2nd FLOOR O P SF PH NE � 3rd FLOOR W MAI IN l , �'Gr N ADDRESS "I STATFJZIP SF E CITY GARAGE R r SF I here affirm that I am licensed under provisions of chapter 9(comment nt STORAGE with section 70D0)of division 3 of the business and professions code,and SF C my license is in full force an effect. INESS SF DECK&BALCONIES C) LICENSE# �,�, �j a/CI N AND CLASS ( f OTHER: T AME VALUATION: jS ✓ A MAILING C ADDRESS/r���✓�`-' STATEl�7fP �O�p�O T CI FEES O - DATE R- C RACTOR'S SfG ATUR BUILDING PERMIT $ •ry1 LfCENSE# • I 0 NA - . PLAN GHEcK 1f AI lc R MAILIN PLAN REVIEW C ADDRESS ZIP H NE H S p CI SEISMIC CONST. [INEW OCC GRP./ DIVISION: TYPE: PLAN RETENTION Q ADDITION NUMBER OF ❑ ALTERATION NUMBER OF BEDROOMS: ❑ OTHER STORIES: ❑ SINGLE FAMILY ZONE: ❑ APARTMENTS YES ❑ CONDOMINIUM HAZARD NO C] I certify that I have read this appfication and state that the 0 TOWN HOMES AREA? I above information is correct. I agree to come Y with all city ❑ COMMERCIAL SPRINKLERS YES NO and county ordinances and state laws relating to-building ❑ INDUSTRIAL REQUIRED? construction. and hereby authorize representatives of this ❑ REPAIR PROPOSED USE OF BLDG: city to enter upon the above-mentioned property for fnsp- ❑ DEMOLISH PRESENT USE OF-BLDG: tion purposes jOB DESCRIPTION Sig ature of APp [icant or Agent Date (� contractor ❑ owner Ll Agent for _ Cfn_r: rfj[II i f.•' ST-In- i, ewer: 1 Agents Narne gre: ,.' iia u1i receipt nQ� 6009 Agents Address _ hp Street City State Zip Irai+s Yuiribier; VC =Et C�frCf u428:46 ' w f Version#43.7 .QM' ■ ®- - SolarCit ESS� ��. WS sly; y �k RA 'PP� c� L ' C 75189 X May 15, 2015 W j Project/Job #9256502 RE: COVER LETTER Project: Amber Leaf Lot 194 Residence l,9TF QF CA\.\F�� 36434 Geranium Dr Lake Elsinore, CA 92532 To Whom It May Concern, Structural review was based on truss calculations for Amber Leaf Lot 194 Phase 1-4 and the design criteria listed below: Design Criteria: -Applicable Codes = 2013 CBC,ASCE 7-10,and 2012 NDS - Risk Category = II -Wind Speed = 110 mph, Exposure Category C -Ground/Roof Snow Load = 0 psf - MPI: Roof DL = 16 psf, Roof LL = 20 psf On the above referenced project,the components of the structural roof framing impacted by the installation of the PV assembly have been reviewed. After this review it has been determined that the existing structure is adequate to withstand the applicable roof dead load, PV assembly load, and live/snow loads indicated in the design criteria above. The structural roof framing and the new attachments that directly support the gravity loading and wind uplift loading from PV modules have been reviewed and determined to meet or exceed structural strength requirements of the 2013 CBC. Please contact me with any questions or concerns regarding this project. Sincerely, Sri Raghavan, P.E. Professional Engineer T: 888.765.2489 x55470 email: sraghavan@solarcity.com 3055 Clearview Way San Mateo, CA 94402 T(650) 638-1028 (888)SOL-CITY F(650) 638-1029 solarcity.com ' 4 f I , � 05.15.2015 SolarCityPV System Structural Version #43.7 Design Software PROJECT INFORMATION & TABLE OF CONTENTS Project Name: Amber Leaf Lot 194 Residence AHJ: Lake Elsinore Job Number: 9256502 Building Code: 2013 CBC Customer Name: Day,Tim And Kristi Based On: IRC 2012/ IBC 2012 Address: 36434 Geranium Dr ASCE Code: ASCE 7-10 City/State: Lake Elsinore, CA Risk Category: II Zip Code 92532 Upgrades Req'd? No Latitude/ Longitude: 33.661590 -117.277960 Stamp Req'd? Yes SC Office: Murrieta PV Designer: Rahila Talpur Calculations: Jesus Santiago EOR: Sri Ra havan, P.E. Cover Letter 1 Project Information, Table Of Contents, &Vicinity Map 2 Seismic Considerations 3 Structure Analysis (Loading Summary and Member Check) 4 Hardware Design (PV System Assembly) 5 1/2-MILE VICINITY MAP .. - f Ar / y w te r, ~ I 1. f'" tr 11 } srt- N 36434 Geranium Dr, Lake Elsinore, CA 92532 Latitude: 33.66159, Longitude: -117.27796, Exposure Category: C SEISMIC CONSIDERATIONS :. Seismic sign Criteria (per USGS Seismic Design Code ASCE 7-10 Latitude 33.6616 Longitude 117.2780 SRA at Short Period Ss 1.558 USGS SRA at is Period Sl 0.600 USGS Soil Site Class D IBC 1613.5.2 Seismic Desi n Category SDC D USGS Seismic•Check.Required(Ss Yes IBC 1613.1 0.4 Si•SDC.> D)?' ' ALTERATION.LATE.RAL.DESIGN.:10P o EXCEPTION_CHECK..: Weight of Proposed PV System Area Dead Load Weight PV System Weight 349 sf 3 psf 1,047 Ibs Total Weight of PV System W(PV) 1,047 Ibs Weight of Roof on Existing Building Sum Area of MPs with PV 544 sf Portion of Roof Weight Area Dead Load Weight Roof 544 sf 16.0 psf 8,704 Ibs Ceiling 544 sf 5.0 psf 2,720 Ibs Interior Walls(Top Half) 373 sf 5.0 psf 1,866 Ibs Exterior Walls(Top Hal 373 sf 8.5 psf 3,172 Ibs Net Weight of Roof Under PV I W(exist) 16,462 Ibs Check% Increase of Roof Weight/ Seismic.Shear Load %-Increase of DCR of-Lateral 6.4% Force Resisting stem W(Pv�(W(exist) Increase Seismic Shear <�10%,.-> (OK] IBC Sect. 3404.4 Note: Seismic base shear is directly proportional to roof weight. i STRUCTURE:ANALYSIS' LOADING SUMMARY AND:MEMBER CHECK MP1'.�. . . _ Member Properties Summary Horizontal Member Spans Rafter Properties MPl Overhang 1.16 ft Actual W 1.50" Roof System Properties Span 1 7.00 ft Actual D 3.50" Number of Spans w/o Overhang) 3 Span 2 6.50 ft Nominal Yes Roofing Material Spanish Tile Roof San 3 2.67 ft A 5.25 in.A2 Re-Roof No San 4 S. 3.06 in.A3 Plywood Sheathing Yes San 5 I 5.36 in.A4 Board Sheathing None Total Span 17.33 ft TL DefPn Limit 120 Vaulted Ceiling No PV 1 Start 1.25 ft Wood Species MSR Ceiling Finish 1/2"Gypsum Board PV 1 End 13.92 ft Wood Grade Rafter Sloe 180 PV 2 Start I Fb 1650 psi Rafter Spacing 24"O.C. PV 2 End F„ 160 psi Top Lat Bracing Full PV 3 Start E 1500000 psi Bot Lat Bracing I At Supports PV 3 End Emi„ 766000 psi Member Loading mary Roof Pitch 4/12 Initial Pitch Ad'ust Non-PV Areas PV Areas Roof Dead Load DL 16.0 psf x 1.05 16.8 psf 16.8 psf PV Dead Load PV-DL 9.0 psf x 1.05 9.5 Psf Roof Live Load RLL 20.0 psf x 1.00 20.0 psf Live/Snow Load LL/SL1,2 Total Load(Governing LC TL 16.8 psf .26.3 psf Notes: 1. ps=Cs*pf;Cs-roof,Cs-pv per ASCE 7[Figure 7-2] 2. pf=0.7(Ce)(Ct)(IS)p9; Ce=0.9,Ct=1.1,IS=1.0 Member Design Summary(per NDS) Governing Load Comb CD CL + CL - CIF Cr 13 -- 0.9 a1.00 0.96 - 1 .1.15 . Member Analysis Results Summary Maximum Max Demand @ Location Capacity DCR Shear Stress 51 psi 1.2 ft. 144 psi 0.36 Bending + Stress 734 psi 4.0 ft. 1708 psi 0.43 Bending (-)Stress -1045 psi 8.2 ft. -1645 psi 0.64 (Governs) Total Load Deflection 0.18 in. 487 4.3 ft. 0.74 in. 120 0.25 CALCULATION.OF DESIGN WIND LOADS -`MP1: = _ Mountina Plane Information Roofing Material Spanish Tile Roof PV System Type SolarCity SleekMountTm Spanning Vents No Standoff Attachment Hardware SM Tile Roof Slope 180 Rafter Spacing 24"O.C. Framing Type/Direction Y-Y Rafters Purlin Spacing X-X Purlins Only NA Tile Reveal `" Tile Roofs Only 13" Tile Attachment System Tile Roofs Only SM Tile Standin Seam/Trap Seam/Trap Spacing SM Seam Only NA Wind Design Criteria Wind Design Code ASCE 7-10 Wind Design Method Partially/Fully Enclosed Method Basic Wind Speed V 110 moh Fig. 26.5-1A Exposure Category C Section 26.7 Roof Style Gable Roof Fig.30.4-2A/B/C-5A/B Mean Roof Height h 25 ft I Section 26.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ 0.95 Table 30.3-1 Topographic Factor Krt 1.00 Section 26.8 Wind Directionality Factor Kd 0.85 Section 26.6-1 Importance Factor I NA Velocity Pressure qh qh = 0.00256(Kz) (Kzt)(Kd)(V^2) Equation 30.3-1 24.9 psf Wind Pressure Ext. Pressure Coefficient U G -0.88 Fig.30.4-2A/B/C-5A/B Ext. Pressure Coefficient Down G Down, 0.45 Fig.30.4-2A/B/C-5A/B Design Wind Pressure p p =qh (GC ) Equation 30.4-1 Wind Pressure U- P -21.8 psf Wind Pressure Down 16.0 psf ALLOWABLE STANDOFF SPACINGS X-Direction Y-Direction Max Allowable Standoff Spacing Landscape 72" 39" Max Allowable Cantilever Landscape 24" NA Standoff Configuration Landscape Not-Staggered Max Standoff Tributary Area Trib 20 sf PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff T-actual -222 Ibs Uplift Capacity of Standoff T-allow 446 Ibs Standoff Demand/Capacity DCR 49.7% X-Direction Y-Direction Max Allowable Standoff Spacing Portrait 48" 64" Max Allowable Cantilever Portrait 19" NA Standoff Configuration Portrait Not-Staggered Max Standoff Tributary Area Trib 21 sf PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff T-actual -244 Ibs Uplift Capacity of Standoff T-allow 446 Ibs Standoff Demand/Capacity DCR 54.7% ABBREVIATIONS ELECTRICAL NOTES INDEX LEGEND LICENSE A AMPERE 1. WHERE ALL TERMINALS OF THE DISCONNECTING PV1 COVER SHEET PV2 SITE PLAN UTILITY METER & WARNING LABEL CA # 888104 O AC ALTERNATING CURRENT MEANS MAY BE ENERGIZED IN THE OPEN C-10 POSITION, A SIGN WILL BE PROVIDED WARNING PV3 STRUCTURAL VIEWS BLDG BUILDING INVERTER W/ INTEGRATED DC DISCO Ben Liu OF THE HAZARDS PER ART. 690.17. PV4 SINGLE LINE lnv CONC CONCRETE PV5 ELECTRICAL CALCULATIONS & WARNING LABELS CDC COMBINER BOX 2. EACH UNGROUNDED CONDUCTOR OF THE PV6 SITE PLAN PLACARD MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED °C DC DISCONNECT & WARNING LABELS U D DISTRIBUTION PANEL BY PHASE AND SYSTEM PER ART. 210.5. CUTSHEETS ATTACHED DC DIRECT CURRENT 3. A NATIONALLY-RECOGNIZED TESTING ( ) EXISTINGEGC NT GROUNDING CONDUCTOR LABORATORY SHALL LIST ALL EQUIPMENT IN © AC DISCONNECT & WARNING LABELS EMT ELECTRICAL METALLIC TUBING COMPLIANCE WITH ART. 110.3. G SOLAR GUARD METER 4. CIRCUITS OVER 250V TO GROUND SHALL GALV GALVANIZED COMPLY WITH ART. 250.97, 250.92(B) JUNCTION BOX ALL EXPOSED CONDUIT WILL BE 5. DC CONDUCTORS EITHER DO NOT ENTER PAINTED TO MATCH HOUSE. GND GROUND GEC GROUNDING ELECTRODE CONDUCTOR BUILDING B O R ARE T RUN I T METALLIC LIC RACEWAYS GENERAL NOTES cO DC COMBINER BOX & WARNING HDG HOT DIPPED GALVANIZED ALL LABELS WILL BE MADE FROM I CURRENT DISCONNECTING MEANS PER ART. 690.31(E). Imp CURRENT AT MAX POWER 6. ALL WIRES SHALL BE PROVIDED WITH STRAIN 1. THIS SYSTEM IS GRID-INTERTIED VIA A OD DISTRIBUTION PANEL & WARNING REFLECTIVE MATERIAL. INVS INVERTERS RELIEF AT ALL ENTRY INTO BOXES AS UL-LISTED POWER-CONDITIONING INVERTER. Isc SHORT CIRCUIT CURRENT REQUIRED BY UL LISTING. 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. Lc LOAD CENTER & WARNING LABELS SMOKE AND CARBON MONOXIDE kVA KILOVOLT AMPERE 7. MODULE FRAMES SHALL BE GROUNDED AT THE 3. PHOTOVOLTAIC SOURCE AND INPUT CIRCUITS AND kW KILOWATT UL-LISTED LOCATION PROVIDED BY THE INVERTER INPUT CIRCUIT ARE UNGROUNDED. DETECTORS TO BE INSTALLED PER LBW LOAD BEARING WALL MANUFACTURER USING UL LISTED GROUNDING 4. SOLAR MOUNTING FRAMES ARE TO BE GROUNDED y . DEDICATED PV SYSTEM METER CRC R314 AND R315. MIN MINIMUM HARDWARE. 5. ALL WORK TO BE DONE TO 2013 CALIFORNIA ofC& s NrUN�I�kR BUILDING CODE. IT.RU11 * (N) NEW 8. ALL EXPOSED METAL PARTS (MODULE FRAMES, info NEC NATIONAL ELECTRIC CODE RAIL, BOXES, 6. ALL ELECTRICAL WORK SHALL COMPLY WITH THE GA f�OLn A A LADDER SHALL BE SET UP AND ETC.) SHALL BE GROUNDED USING p�roval NIC NOT IN CONTRACT UL LISTED LAY-IN LUGS LISTED FOR THE 2011 NATIONAL ELECTRIC CODE AS AMENDEQ BY --- INTERIO Q IPME T READY FOR THE INSPECTION. NTS NOT TO SCALE PURPOSE. POSTS SHALL BE MADE THE 2013 CALIFORNIA ELECTRIC CODE. /tPp Ved By; OC ON CENTER ELECTRICALLY CONTINUOUS WITH ATTACHED P PANEL BOARD RAIL. �� Cj I TAT OF LAKE E LS I N O R PL PROPERTY LINES 9. MODULE FRAMES, RAIL, AND POSTS SHALL BE PV PHOTOVOLTAIC BONDED WITH EQUIPMENT GROUND CONDUCTORS �` J i L D i N G DIVISION PVC POLYVINYL CHLORIDE AND GROUNDED AT THE MAIN ELECTRIC PANEL. y...w S SUBPANEL 10. IF THE EXISTING AC GROUNDING ELECTRODE IS VICINITY MAP SCH SCHEDULE A COPPER ROD, THE DC GEC SHALL BE EITHER SS STAINLESS STEEL #8 THWN-2 RUN INSIDE CONDUIT BONDED AT SSD SEE STRUCTURAL DRAWINGS BOTH ENDS, OR #6 BARE COPPER RUN ALONG 3. t 5 - 2- 7 STC STANDARD TESTING CONDITIONS BUILDING AS LONG AS IT IS NOT SUBJECT TO tiraTl y Enjurmnr _r f SWH SOLAR WATER HEATER PHYSICAL HARM PER ART. 250.166(B)&(C), i. TYP TYPICAL 250.64(B)&(E). IF THE EXISTING AC GROUNDING �Intleiri Irma °�f'"� UON UNLESS OTHERWISE NOTED ELECTRODE IS A CONCRETE-ENCASED 1 nshcim I.1 in ��1 UPS UNINTERRUPTIBLE POWER SUPPLY ELECTRODE, THE DC GEC SHALL BE A #6 ` ; prig V VOLT THWN-2 PER ART. 250.166(D). THE GEC SHALL i err y I + 1+>k�la r.� PP�0��D Vmp VOLTAGE AT MAX POWER BE CONTINUOUS AS DESCRIBED IN ART. `�nt ,Mlle ` '�1"v Hn`r"i Hemet G w� Voc VOLTAGE AT OPEN CIRCUIT 250.64(C). � 11.41 W WATT Na rch I�aN p n f tor, IrA,n, 4 r 3R NEMA 3R, RAINTIGHT E` rle f L glLlia hdarririrr v;• REV BY DATE COMMENTS N.gUN � TrmrrtiIn �� .5L-in ckmicnte rJ W..Li -LGc- a.114 E,a. 7Q,row a'I•z R,:Gari:, 7G CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER: J B-9256502 00 PREMISE OWNER: AHJ: Lake Elsinore DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE DAY TIM AND KRISTI RTALP $. AMBER LEAF—LOT 194 solarCity,BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MARKET: MODULES .,,NOR SHALL IT BE DISCLOSED IN WHOLE OR IN REST 20 KYOCERA KU2606XPA 36434 GERANIUM DR 5.2 kW ROOF MOUNT PV SYSTEM ►� PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZIZATION, EXCEPT IN CONNECTION WITH PROJECT MANAGER: MOUNTING SYSTEM: LAKE ELSINORE, CA 92532 THE SALE AND USE OF THE RESPECTIVE ZS TILE 3055 Clearview way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE; San Mateo,CA 94402 PERMISSION OF SOLARCITY INC. PAYMENT TYPE: INVERTER: T(650)638-1028 I F:(650)638-1029 LEASE (1) ABB # PVI-4.2-OUTD-S-US-Z-A COVER SHEET PV 1 5/13/2015 (888)-SOL-CM(765-2489) 1 www.solarcity.com . - Roof Mounted SEE PV3 DETAILS MP1 PITCH: 18 ARRAY PITCH: 18 AZIMUTH: 170 ARRAY AZIMUTH: 170 MATERIAL: Low Profile W-Tile STORY: One Story CA # 888104 C-10 Ben Liu �- o STAMPED & SIGNED LEGEND FOR STRUCTURAL ONLY (E) UTILITY METER & WARNING LABELS M (2) (4) (6) (10)* INVERTER W/ INTEGRATED DC DISCO FESS/ In. & WARNING LABELS (3),(5) �Nq © DC DISCONNECT & WARNING LABELS (3),(5) rLU C 75189 9Z rn ® AC DISCONNECT & WARNING LABELS (2),(4) I B O JUNCTION BOX & WARNING LABEL (9) I `rjy CIV11. ��P rF pF CA1-W O DC COMBINER BOX & WARNING LABEL (9) DISTRIBUTION PANEL & WARNING D LABELS (2),(4),(6) A j LC LOAD CENTER & WARNING LABELS 3' MIN. PV3 j 3' MIN. (2),(4),(6),(7) FIRE SETBAC K FIRE SETEj CK O DEDICATED PV SYSTEM METER (7) 1 1 -_ CONDUIT RUN ON EXTERIOR (8) AC AC --- CONDUIT RUN ON INTERIOR (8) r. EfS_� GATE - INTERIOR EQUIPMENT , ,Inv,' O -- L\ *( ) NUMBERS REFER TO LABELS DRIVEWAY ON CUTSHEET PAGE FRONT OF HOUSE STREET SITE PLAN N Scale: 3/32" = 1' w E 01, 10, 21' S J B-9 2 5 6 5 0 2 00 PREMISE OYMER: AHJ: Lake Elsinore DESCRIPTION: DESIGN: CONFIDENTIAL S — THE INFORMATION HEREIN JOB NUMBER: DAY, TIM AND KRISTI AMBER LEAF—LOT 194 RTALP �``�. • CONTAINED SHALL NOT E USED FOR THE SolarCity. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MARKET: MODULES: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN 36434 GERANIUM DR PART TO OTHERS OUTSIDE THE RECIPIENTSREST 20 KYOCERA KU2606XPA 5.2 kW ROOF MOUNT PV SYSTEM ORGANIZATION, EXCEPT IN CONNECTION WITH PROJEcr MANAGER: MOUNTING SYSTEM: LAKE ELSINORE, CA 92532 THE SALE AND USE OF THE RESPECTIVE ZS TILE 3055 Clearview way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET: REV: DATE: San Mateo,CA 94402 PERMISSION OF SOLARCITY INC. PAYMENT TYPE: INVERTER: T:(650)638-1028 1 F:(650)638-1029 LEASE (1) ABB # PVI-4.2-OUTD-S-US-Z-A SITE PLAN PV 2 5 13 2015 / / (888)-SOL-CITY(765-2489) 1 www.solarcity.com CA # 888104 C-10 INSTALLATION ORDER Een Liu " DIA THREADED STUD REMOVE TILE, LOCATE & MARK & NUT (1) RAFTER LOCATION.PLACE STANDOFF I ZEP LEVELING FOOT --- ---- - ---- - - -- ---- -- ---- BASE & DRILL PILOT HOLES. ZEP TOP ARM 2) CLEAN PAPER AROUND PILOT HOLE. ZEP ANTI-ROTATION PLATE (6) 6' MAX. BETWEEN M10 BOLTS SEAL PILOT HOLES AND BOTTOM OF FOOTINGS MOUNTING BASE ��(5) �(3) STANDOFF WITH POLYURETHANE (E) TILE (1) SEALANT. (E) ROOF DECKING - 4) LAG STANDOFF BASE INTO RAFTER. ¢ (E) RAFTER (4) (2) DIA LAG BOLT (3) 5) PLACE FLASHING AND ATTACH (2- " EMBED, MIN) SEALING SPACER WITH SINGLE BOLT. (N) ZEP INTERLOCK PLACE ZEP BAR. THEN INSTALL 2' TY ((6) LEVELING FOOT WITH BOLT & WASHER. (E) 2x4 RAFTERS @ 24" SPACING STANDOFF B FRONT VIEW OF MP TYP. C Scale: 1/2"=1'-O" Scale: 1 1/2" = 1' STAMPED & SIGNED FOR STRUCTURAL ONLY OF`tSSION,gz Q-� �kAGHqL �LG1 �� sT CND`' / ATE OF Op,� - f'-7"— -7" 2'-8" 2'-8" -�". JIDE VIEW OF MOUNTING PLANE SUPPORT- 2x4 WEB A Scale: 1/4"=1' 0" MAX SPAN: 5'-9" CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER: PREMISE OWNER: AHJ: Lake Flsinore DESCRIPTION: DESIGN: JB-9256502 00 CONTAINED SHALL NOT USED FOR THE DAY, T M AND KRISTI AMBER LEAF—LOT 194 RTALP SolarCity, BENEFIT ANYONE EXCEPT SOLARCITYINC., MARKET: MODULES: ' NOR SHALLLL IT BE DISCLOSED IN WHOLEOLEOR IN RESI 20 KYOCERA KU2606XPA 36434 GERANIUM DR 5.2 kW ROOF MOUNT PV SYSTEM �,� PART TO OTHERS OUTSIDE THE RECIPIENT ORGANIZATION, EXCEPT IN CONNECTION WITH PROJECT PROJECT MANAGER: MOUNTING SYSTEM: LAKE ELSINORE, CA 92532 THE SALE AND USE OF THE RESPECTIVE ZS TILE 3055 Clearview Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PACE NAME: SHEET: REV: DATE San Mateo 40 CA 942 : PERMISSION OF SOLARCITY INC. PAYMENT TYPE: INVERTER: T:(650)638-1028 i F:(650)638-1029 LEASE (1) ABB # PVI-4.2-OUTD-S-US-Z-A STRUCTURAL VIEWS PV 3 5/13/2015 1(888)-SOL-CITY(765-2489) 1 www.solarcity.coni GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE WITH IRREVERSIBLE CRIMP aer Nurnbe: INV 1 -(1 ,- vi-4.2-.j_� FCI Inverter; Zigbee 420OW, 240V, 96% PV Module; 260W, 232.9W PTC, 40MM, Blk Frame, H4, ZEP, 1000V, w/Bo kbor Underground r- Lntran::r INV 2 Vnc 3R 3 Vpmax: 31 INV 3 +RE SHOWN IN THE DC STRINGS IDENTIFIER E 211A MAIN SERVICE PANEL E 20OA/2P MAIN CIRCUIT BREAKER ADJUST MIN. ACTIVATION VOLTAGES! CUTLER-HAMMER CUTLER-HAMMER Inverter 1 IND F Disconnect Disconnect 5 4 11 A 1 DC+ Vstart = 120V DC- MP 1: 1x10 F1l al, B �'.0 zao� r--------- ' --------------------- -- -- Etc-------------- - -- � - _ - L1 L2 I DC+ I N DC- 1 3 2 ___ GND -_--_--- GND ------------- ------------___EGCI ___ pC+ DC+ VStart = 120V 1 1113) A r GEC N DC- DC- MP 1: 1x10 '} I e I --------------1---JD' EGC -- --------- ------------!---�---- -- -- EGC- I v I (I Konduit Ka 3'a" F M T N I I EGC/GEC J Z 2 U' GEC TO 120/240V 1 SINGLE PHASE UTILITY SERVICE 1 1 1 1 1 Ben Li U Voc* = MAX VOC AT MIN TEMP OI g ( � Ui LH ct, 30 t , Non-Fusible, NEMA 3R z2SG , UNFSED 1)CUTLER-HAMMER DG030N6 AC GROUNDED DC Ground/Neutral it, 30A, General Duty(DG) (1)CUTLER-HAMMER M DG321UG8 Disconnect; 30A, 240Vac, Non-Fusible, NEMA 1 1)CUTLER-HAMMER N DG030N6 Ground/Neutral it, 30A, General Duty(DG) (1)AWG II10, THAN-2, Black , I (1)AWG M10, THWN-2, Block Voc* =434.02 VDC Isc =9.09 ADC (2)AWG #10, PV Wire, 60OV, Block Voc` = 434.02 VDC 1 5 L l (1)AWG #10. THWN-2, Red (1)AWG #10, THWN-2, Red Vmp = 310 VDC Imp=8.39 ADC 1)AWG #10, Solid Bare Copper EGC Vmp =310 VDC Imp=8.39 AF', ILL (1)AWG #10, THAN-2, White NEUTRAL Vlnp =240 VAC Imp (I)AWG #10, THWN-2, Green EGC �J -(1)AWG /8, THWN-2, Green EGC/GEC -(1)Conduit Kit; 3/4" EMT (I)AWG #10, THWN-2, Block Voc* =434.02 VDC Isc =9.09 ADC (2)AWG p10, PV Wire, 60OV, Black Voc* =434.02 VDC Isc - 9 09 AD (1)AWG #10, THWN-2, Red Vmp =310 VDC Imp=8.39 ADC O (1)AWG #10, Solid Bare Copper EGC Vmp =310 VDC Imp=8.39 AD (1)AWG p10, THWN-2, Green EGC J B-9 2 5 6 5 0 2 0 0 PREMISE OWNER: AH k Lake Elsinore DESCRIPTION: DESIGN: CONFIDENTIAL THE INFORMATION HEREIN loe NUMBER: DAY, TIM AND KRISTI AMBER LEAF-LOT 194 RTALP _��_`�. ■ CONTAINED SHALL NOT E USED FOR THE SO�af��ty BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MARKET: MODULES: ' . (` NOR SHALL IT BE DISCLOSED IN WHOLE OR IN REST 20 KYOCERA KU2606XPA 36434 GERANIUM DR 5.2 kW ROOF MOUNT PV SYSTEM o PART TO OTHERS OUTSIDE THE RECIPIENT ORGANIZATION, EXCEPT IN CONNECTION WITH S PROJECT MANAGER: MOUNTING SYSTEM: LAKE ELSINORE, CA 92532 IZ THE SALE AND USE OF THE RESPECTIVE ZS TILE 3055 Clearview way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET: REV: DATE: San Mateo,CA 94402 PERMISSION OF SOLARCITY INC. PAYMENT TYPE: INVERTER: T:(650)638-1028 1 F:(650)638-1029 LEASE (1) ABB # PV1-4.2-0UTD-S-US-Z-A SINGLE LINE PV 4 5/13/2015 (888)-SOL-CrlY(765-2489) 1 www.solarcity.com 1. Conducto: Sizing per Art 690.8(B1(1) a. Gonductor must have 30 deg. C ampacity >= 125% of continuous ELECTRICAL CALCULATIONS current per Art 215.2(A)(1). b. Conductor must have (after corrections for conditions of use) >= String and 2 Combined Strings continuous current per Table 310.15(8)(16). Module Type: Module Count: Icont = (Amps): c. Evaluate conductor temperature at terminations per 110.14(C). Kyocera 260 1000V 20 11.36 Ampacity of wire derated for conditions of termination must be >= Branch Circuit Individual MPPT continuous current*1.25. All string terminations are rated at 90' C. -_ _________________________________ 1 strings per Branch A 1 strings per Branch B 2. OCP Sizing per Art 690.8(8)(1) 10 modules per series string 10 modules per series string a. Round up to next size per Art 240.4(8) ___________________________________________ String_ Branch A Branch B 3. Conductor Sizing per Art 690.8(B)(1) Conductor: Conductor: Conductor: a. Conductor must have 30 deg. C ampacity >= 125% of continuous ICOnt * 1.25 = (Amps) 14.2 14.2 14.2 current per Art 215.2(A)(1). 30 deg C ampacity = 40 40 40 b. Conductor must have (after corrections for conditions of use) >= PV Wire Size: AWG #10 AWG #10 AWG #10 continuous current per Table 310.15(B)(16). Icont = (Amps) 11.36 11.36 11.36 c. Evaluate conductor temperature at terminations per Art 110.14(C). Start ampacity 40 40 40 Ampacity of wire derated for conditions of termination must be >= Temperature derate (%=F) 0.71 0.71 0.71 continuous current*1.25. All branch terminations are rated at 75' C min. Conduit fill derate (%_#) 1 0.8 0.8 ------------------------------------------ Derated ampacity 28.4 22.72 22.72 4. OCP Sizing a. Round up to next size per Art 240.4(B) ICOnt * 1.25 = (Amps) 14.2 14.2 14.2 5. Conductor Sizing per Art 690.8(B Ampacity 40 40 40 )(1) a. Conductor must have 30 deg. C ampacity >= 125% of continuous Inverter Output current per Art 215.2(A)(1). Inverter Type: Inverter Count: Total b. Conductor must have (after corrections for conditions of use) >= ABB PVI-4.2-S AFCI 1 Icont = (Amps): continuous current per Table 310.15(B)(16). 20 c. Evaluate conductor temperature at terminations per Art 110.14(C). Ampacity of wire derated for conditions of termination must be.>= ICOnt * 1.25 = (Amps) 25 continuous current*1.25. All inverter output terminations are rated at OCP Size = 25 75' C. ------------------------------------------- Conductor 3: AWG #10 THWN-2 6. OCP Sizing Icont * 1.25 = (Amps) 25 a. Round up to next size per Art 240.4(B) 30 deg Campacity = 40 7. Conductor Sizing per Art 690.8(B)(11 Icont = (Amps) 20 a. Conductor must have 30 deg. C ampacity >= 125% of continuous Start ampacity . 40 current per Art 215.2(A)(1). Temperature derate (%=F) 0.91 b. Conductor must have (after corrections for conditions of use) >= Conduit fill derate (%-#) 1 CA 888104 continuous current per Table 310.15(B)(16). # Derated ampacity 36A c-10 c. Evaluate conductor temperature at terminations per Art 110.14(C). ICOnt * 1.25 = (Amps) 25 Ben Liu Ampacity of wire derated for conditions of termination must be >= Ampacity 35 CD continuous current*1.25. All inverter output terminations are rated at 75' C min. PREMISE OWNER: AHJ: Lake Elsinore DESCRIPTION: DESIGN: CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: J g-9256502 00 CONTAINED MALL NOT BE USED FOR THE DAY, TIM AND KRISTI AMBER LEAF-LOT 194 RTALP solarCity. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MARKET: MODULES: �NOR SHALL IT BE DISCLOSED IN WHOLE OR IN 36434 GERANIUM DR 5.2 kW ROOF MOUNT PV SYSTEM ►� PART TO OTHERS OUTSIDE THE RECIPIENTS RESI 20 KYOCERA KU2606XPA ORGANIZATION, EXCEPT IN CONNECTION WITH PROJECT MANAGER: MOUNTING SYSTEM: LAKE ELSINORE, CA 92532 3055 Clearview Way THE SALE AND USE OF THE RESPECTIVE ZS TILE PAGE NAME: SHEET: REV: DATE: San Mateo,CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAYMENT TYPE: INVERTER: T:(650)638-1028 1 F:(650)638-1029 PERMISSION OF SOLARCITY INC. LEASE (1) ABB # PVI-4.2-0UTD-S-US-Z-A ELECTRICAL CALCULATIONS PV 5 5/13/2015 (888)-SOL-CrrY(765-2489) 1 www•solarcity.com CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: 36434 GERANIUM DR SOLAR PHOTOVOLTAIC ON ROOF AC DISCONNECT X UTILITY DISCONNECT XX X X UTILITY SERVICE INVERTER FRONT OF HOME PHOTOVOLTAIC BACK-FED CIRCUIT BREAKER IN MAIN ELECTRICAL PANEL IS A/C DISCONNECT PER NEC 690.17 - OPERATING VOLTAGE = 240V MAX CURRENT = 20A —(1)Site Plan Placard Custom site plan placard Ben Li U �- a PREMISE OWNER: AHJ: Lake Elsinore DESCRIPTION: DESIGN: CONFIDENTIAL THE INFORMATION HEREIN JOB NUMBER: J B-9256502 � 00 RTALP �\`� � CONTAINED SHALL NOTCE USED FOR THE DAY, TIM AND KRISTI AMBER LEAF—LOT 194 �_ SO�afC�ty NOR SHALL IT BEBENEFIT OF NDISCLOOSSED IN VMO�INC., MARKET: MODULES- NOR 36434 GERANIUM DR 5.2 kW ROOF MOUNT PV SYSTEM '��� PART TO OTHERS OUTSIDE THE RECIPIENT'S REST 20 KYOCERA KU2606XPA ORGANIZATION, EXCEPT IN CONNECTION WITH PROJECT MANAGER: MOUNTING SYSTEM: LAKE ELSINORE, CA 92532 THE SALE AND USE OF THE RESPECTIVE ZS TILE 3055 Clearview Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME MEET- REV: DATE: San Mateo,CA 94402 PERMISSION Of SOLARCITY INC. PAYMENT TYPE IN TER: 5 1 3 201 5 T:(650)638-1028 1 F:(650)638-1029 LEASE ()TER # PV1-4.2-0UTD-S-US-Z-A SITE PLAN PLACARD PV 6 / / (888)SOL-CITY(7652489) www.solarcity.com WARNING:PHOTOVOLTAIC POWER SOURCE Label Location: Label Location: Label Location: PV SYSTEM WARNING Code:Per DISCONNECT FOR ••_ UTILITY OPERATION ELECTRIC SHOCK HAZARD •• THE DC CONDUCTORS OF THIS LabelPHOTOVOLTAIC SYSTEM ARETO BE USED WHEN PHOTOVOLTAIC DC INVERTERIS MAY BEOENDERG ZED DISCONNECTPer Code: UNGROUNDED CEC .•0 .14.C.2 Label Location: WARNING ' Per ..- ELECTRIC SHOCK HAZARD•" Location: CEC 690.17 DO NOT TOUCH TERMINALS MAXIMUM POWER- q OADMSrIDES MAY BE ENERGIZED POINT CURRENT(Imp)_ Code: ,._ IN THE OPEN POSITION MAXIMUM POWER vCEC •. 0.53 POINT VOLTAGE(Vmp) MAXIMUM SYSTEM_v VOLTAGE(Voc) SHORT-CIRCUIT_ CURRENT(Isc) A Label Per WARNING ..- INVERTER OUTPUT CONNECTION LabelDO NOT RELOCATE WARNING Per THIS OVERCURRENT DEVICE •.- ELECTRICALSHOCK HAZARD DO NOT TOUCH TERMINALS 690.17 TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION Label • • DC VOLTAGE IS PHOTOVOLTAIC POINT OF Per ALWAYS PRESENT WHEN INTERCONNECTION Code: CEC SOLAR MODULES ARE WARNING: ELECTRIC SHOCK EXPOSED TO SUNLIGHT HAZARD. DO NOT TOUCH •• CEC 690.17 TERMINALS.TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION. FOR SERVICE LabelDE ENERGIZE BOTH SOURCE WARNING Per AND MAIN BREAKER. PV POWER SOURCE Code:CEC MAXIMUM AC ELECTRIC SHOCK HAZARD 690.5(C) OPERATING CURRENT _ A. IF A GROUND FAULT IS INDICATED NORMALLY GROUNDED MAXIMUM AC _ V CONDUCTORS MAY BE OPERATING VOLTAGE UNGROUNDED AND ENERGIZED Label • • Label Location: PHOTOVOLTAIC AC Code:CAUTION ' P• Disconnect I) Per• PHOTOVOLTAIC SYSTEM DISCONNECTCode: CIRCUIT IS BACKFEDCEC 690.64.B.4 • .•0 • - :. Conduit(D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Label Location: Label Location: (INV): MAXIMUMAC A CAUTION Inverter �� OPERATING CURRENT Center Code: DUAL POWER SOURCE Code: •.• MAXIMUM AC SECOND SOURCE IS (POI): • Point . • • OPERATING VOLTAGE V (M): Utility Meter 690.54 PHOTOVOLTAIC SYSTEM ' San Mateo,CA 94402 • Label Set • • • ' I • l `ii,SOlarCity ZepSolar Next-Level PV Mounting Technology li�,SOlarCity Zep Solar Next-Level PV Mounting Technology Zep System Components for the roofs using replacement tiles i a�i�F•at "xn ro T"p Arm—d / Tep Arm-he ro r AntFPotation Plate.74 / w Fashl.%r 1Mounnng t ` Replacement S-Tiles Part No.850-1435 To p Arm—_-----t d i Listed to UL 2703 I AaA-- I J - nes ro me Fleming •"°"°rr"t'" aa•e Replacement W-Tile npatsn�n;w I Part No.850-1437 j Listed to UL 2703 'I j •"itl1e P:neaeni rane. Re t lacement Flat Tile ~Ng t,ro saner Replacement Part No.850-1436 Listed to UL 2703 i Q�oMPA T� tiW /°�� Description rQO� PV mounting solution for concrete tile roofs ore caMPPt Works with all Zep Compatible Modules • Zep System UL 1703 Class A Fire Rating for Type 1 and Type 2 modules Auto bonding UL-listed hardware creates structual and electrical bond V� Tile Roof Attachment Kit Interlock Leveling Foot LISTED Part No.850-1434 Part No.850-1388 Part No.850-1397 Listed to UL 2582 Listed to UL 2703 Listed to UL 2703 ♦' Specifications E IEV : Designed for pitched roofs Installs in portrait and landscape orientations J • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 • Wind tunnel report to ASCE 7-05 and 7-10 standards ttr� • Zep System grounding products are UL listed to UL 2703 and ETL listed to UL 467 • Zep System bonding products are UL listed to UL 2703 Engineered for spans up to 72"and cantilevers up to 24" Zep wire management products listed to UL 1565 for wire positioning devices Ground Zep Array Skirt,Grip,End Caps DC Wire Clip Attachment method UL listed to UL 2582 for Wind Driven Rain Part No.850-1172 Part Nos.500-0113, Part No.850-1448 Listed to UL 2703 and 850-1421,850-1460, Listed UL 1565 ETL listed to UL 467 850-1467 zepsolar.com zepsolar.com Listed to UL 2703 This document does not create any express warranty by Zep Solar or about its products or services.Zap Solar's sole warranty is contained in the written product warranty for This document does not create any express warranty by Zep Solar or about its products or services.Zap Solar's sole warranty is contained in the written product warranty for each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely responsible for verifying the suitability of Zep Solar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. responsible for verifying the suitability of Zep Solar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. 12 31 14 ZS for Replacement Tile Applications Cutsheet Rev 02.pdf Page: 1 of 2 12 31 14 ZS for Replacement Tile Applications Cutsheet Rev 02.pdf Page: 2 of 2 Solar inverters Additional highlights: — RS-485 communication interface = string inverters (for connection to laptop or data logger). — Integrated Arc Fault Detection and . I Interruption(-A Version). . _ t ( j I Technical data and types Type code PVI-3.0-OUTD-US PVI-3.6-OUTD-US PVI-3.8-OUTD-US PVI-4.2-OUTD-US AU Mechanical specifications Nominal output power 3000W 360OW 3300 380OW 420OW 3000 323001 33001 3600 40001 4000' 3300 42001 4200' 4200 4600' 4600' Maximum output power wattage W W W w w W W W w W W W 1 :"� Rated grid AC voltage 208V 240V 277V 208V 240V 277V 208V 240V 277V 208V 240V 277V demo-z- ._ e Input side(DC) " Number of independent MPPT channels 2 2 2 2 Maximum usable power for each channel 2000W 3000W 3000W 3000W Absolute maximum voltage(Vmax) 600V Start-up voltage(Vstart) 200V(adj.120 350V) Full power MPPT voltage range 160-530V 120-530V 140-530V 140-530V u " Operating MPPT voltage range 0.7 x Vstart-580V(>-90V) ¢ e Maximum current(ldcmax)for both MPPT in 20A 32A 32A 32A parallel i ) Maximum usable current per channel 10A 16A 16A 16A i Maximum short circuit current limit per channel 25A 20.OA 20.OA 20.OA ¢ Number of wire landing terminals per channel 2 pairs j , s.°•a°^^B'°' Array wiring termination Terminal block,pressure clamp,AWG10-AWG4 Output side(AC) Grid connection type _ 1 / Split- 1 10/ plit- 1 / 1 2W O/3W 2W 2W O/3W 2W 2W 0/3W 2W 2W 0/3W 2W - Adjustable voltage range(Vmin-Vmax)(V) 183- 211 - 244 183- 211- 244- 183- 211 244- 183- 211- 244- 228V 264V 304V 228V 264V 304V 228V 264V 304V 228V 264V 304V Grid frequency 60Hz Adjustable grid frequency range 57 60.5Hz Maximum current(1. ,.) 14.5 14.5 12.0 17.2 16.0 16.0 16.0 16.0 16.0 20.0 20.0 20.0 Auras Aunts Auras A_. Aug,.--. Antos - Auras A_ Auras Auras.. Aures Aunts Power factor >0.995 Total harmonic distortion at rated power <2% This family of single-phase string The high-speed MPPT offers real- Highlights: Grid wiring termination type Terminal block Pressure clamp AWG10-AWG4 Inverters complements the typical time power tracking and improved — Single phase and split phase output Input protection devices Reverse polarity protection Yes number of rooftop solar panels energy harvesting. grid connection. Over-voltage protection type Varistor,2 for each channel enabling home-owners to get the most The flat efficiency curve ensures high — Wide input range for increased PV array ground fault detection Pre start-up Riso and Dynamic GFDI(requires floating arrays) efficient energy harvesting for the size efficiency at all output levels allowing Stringing flexibility. Output protection devices of the property. a consistent and stable performance — The high speed and precise MPPT Anti-ivl Over-voltage protection Meets UL 1 stor,2(L -L4/requirements Over-voltage protection type Varistor,2(L-Lz/L G) across the entire input voltage and algorithm offers real time power Maximum AC OCPD Rating 20A„, 20A 15A„ 25A„ 20A„ 20A 2oA 20A 20A,„ 25A 25A 25Ao This inverter offers a dual input output power range. tracking and improved energy Efficiency section that processes two strings The transformerless operation gives the harvesting. Maximum efficiency 96.9% 97% 97% 97% CEC efficiency 96% with independent Multiple Power Point highest efficiency of up to 97.0%. — Outdoor NEMA 4X rated enclosure Operating performance Tracking(MPPT). The wide input voltage range makes for unrestricted use under any Night time consumption <O.6W , This is especially useful for rooftop the inverter suitable to low power environmental conditions. Stand-by consumption <8w . Communication installations with two different installations with reduced string size. — Integrated DC disconnect switch User-interface 16 characters x 2 lines LCD display orientations from two sub-arrays This rugged outdoor inverter has been in compliance with international Remote monitoring(1xRS485 incl.) VSN760 Data Logger(opt.) oriented in different directions. (For designed to be a completely sealed Standards(-S Version). Environmental Ambient air operating temperature range -13°F to+140°F with derating above 122°F(50°C) example: East and West) unit able to withstand the harshest Ambient air storage temperature range 40°F to+176°F(-40°C to+80°C) The dual input sections with environmental conditions. Relative humidity 0-100%RH condensing independent MPPT enable a more Acoustic noise emission level <50 db(A)®1m AL ,� ,� Maximum operating altitutde without derating 6560 ft(2000 m) optimal energy harvesting condition. 1.Capability enabled at nominal AC voltage and with sufficient DC power available. P%,•,• 2 ABB Solar Inverters i Product flyer for PVI-3.0/3.6/3.8/4.2-TL-OUTD KU-60 1000V Series ELECTRICAL SPECIFICATIONS MODULE CHARACTERISTICS l(YOCERa K U 6 0 10 0 0 V Z SeriesStandard ConditionsCells per module: 60(6 x 10) 1000 ' Dimensions: 65.43ini38.98in/1.57in KU255-6XPA KU260-6XPA 60 , length/width/height (1662mmi990mmi40mm) Weight 47.4lbs(21.5kg) CUTTING EDGE TECHNOLOGY -- - Pm. 255 260 w As a pioneer with four decades of experience in the vm° 30.8 31.0 v PACKAGING SPECIFICATIONS development of photovoltaic systems, Kyocera drives the MEMNON market as a leading provider of PV products.We I°° S.zB s.39 A Modules per pallet: zo demonstrate our Kaizen philosophy,or commitment toMENEM v_ 38.0 38.3 V Pallets per53'container. 36 continuous improvement, by setting the industry standard Pallet box dimensions: 66ini40ini43in in the innovation of best-in-class solar energy equipment. Iu 8.83 9.09 A length/width/height (1675mm/1005mmi1055mm) MENNEN P.... +5/-0 +5/-0 % Pallet box weight 1060lbs(480kg) QUALITY BUILT IN Nominal Operating - pe . Conditions • •UV-stabilized,anodized aluminum frame in black • 51" !.onl 4.J3" •Supported by major mounting structure manufacturers MEMENE TNOcr 45 45 °c � "'°"' POTTEO • TN Easily accessible grounding points on all four corners P II 183 187 w = � BOXOP65 for fast installation vmP 27.7 27.9 v -MENNEN =I •Proven junction box technology with 12 AWG PV wire ` CONNEc oR works with transformerless inverters I p 6.61 6.71 A LABEL STABILIZER BAR - •Amphenol H4-UTX locking plug-in connectors MENNEN voc 34.8 35.1 v provide safe,quick connectionsMEMNON lx 7.15 7.36 A PROVEN RELIABILITY PTc zz8.3 232.9 w •Kyocera modules confirmed by the Desert KnowledgeTempeure •. STABILIZER BAR Australia Solar Centre to have the highest average MENNEN output of any crystalline module MENEMP_ -0.45 -0.45 %/°C Ho"ezBm) •First module manufacturer in the world to pass long- v p -0.48 -0.48 %/°C term sequential testing performed by TUV Rheinland Iry 0.02 0.02 %/°C •Only module manufacturer to achieve the rank of "Performance Leader" in all six categories of GTM _ vas -0.36 -0.36 %/°C I 38.98"(990 s) Research's 2014 PV Module Reliability Scorecard Iu 0.06 0.06 %/°C COperating Temp 40 to+90 40 to+90Grounding H°le sl°tL6e•°"nti A bibCERTIFICATIONS 0.16-(4mn) 0.35-0.4T (9-11mn) •UL1703 Certified and Registered,UL Module Fire System D. sign Performance:Type 2,CEC FRAME CROSS SECTION DIAGRAM •NEC 2008 Compliant,IEC 61215j61730,and ISO 14001 Series Fuse mating 15 A i Maximum DC System Voltage(UL) 1000 V _ Q,OMPATie` ,. W C us = Hailstone Impact in(25mm)@ 51 Imp(23m�s) 7L wow LONG/SHORT SIDE STABILIZER BAR NEC 2008 COMPLIANT when r.0 least:,e^l'.c.- UL 1703 DSTED a ,'s e^t e y o:c "^c; e a a^0"G "",, ^G&uDe'd'. 062614 <ycc So a »ocu es. OUR VALUED PARTNER Zep ZS COMP I GROUNDING AND BONDING Zep --- - --- Interlock ZS Cow` I Grounding and Bonding Interlock Zep Zey side This document describes the mechanics of how the electrical bonding is accomplished between the LIL Listed hardware components used in Zep Solar's ZS Comp mounting solution for composition shingle roofs. Part No.850-1388 Zep Compatible-systems do not require running copper conductors to each module.The act of physically UL Listed to UL 2703 installing each component simultaneously establishes an electrical bond,as described in the following XZT.,gue side pages. Key Side Bonding Cutting"tooth" Side view Lr~' Interlock_.,:..... Module ' Ground Zep Interlock(Keyside shown) ; Key side in --- closed position Bonding locations Zep Compatible module on Key side Forced interference rotation with Zep Groove Cutting"tooth" 9 of Interlock Zep causes teeth to cut through anodization on module frame.resulting in robust and UL certified bonding path Tongue Side Bonding Tongue side in closed position ai Leveling Foot Module Down-roof O ZS Comp Cutaway Illustration Forced interference between mating parts from module Cutting"teeth" Bonding location on rock-in motion cuts into module frame,removing Tongueside anodization and resulting in robust and UL certified -411111.- bonding path Document 80 0 4 47 8-0 01 Rev A www.zepsolar.com PAGE: 1 of 5 Document 800-1478-001 Rev A www.zepsolar.corn PAGE: 2 of 5 ®2013/EN Zep Solar.Inc.Zep Solar reserves the right to make specifications chnages without any prior notice.All rights reserved. ®2013/EN Zep Solar.Inc.Zep Solar reserves the right to make specifications ch nages without any prior notice.All rights reserved. Date Last Exported:June 25,2013 4:45 PM Date Last Exported:June 25,2013 4:45 PM Y , ZepSol�)i ZS COMP I GROUNDING AND BONDING ZepS(l,:Ir ZS COMP I GROUNDING AND BONDING Interlock, continued Leveling Foot Tongue side .0 -------P. Key side Spring clip Part No.8o _- U t UL 2 L Listed to UL 703 — — Bondin Path — KeV and Ton ue Part No.850-1397 The Leveling Foot top portion(the Rockit)has a stainless steel 9 7 g UL Listed to UL 2703 spring clip that bonds to the adjacent module frame on both The Interlock bonds modules on all sides to create a hyper- Key and Tongue sides. bonded array where every module is structurally and electrically bonded to the surrounding modules. Leveling Foot - Bonding With Module Frame Module Tongue side O flown-roct 2 O i Interlock Key side Key side inserts into Zep Groove(rock-in) Module in next row drops in on the Tongue side Bonding Path - Array Bonding Path - North and South Modules ® ® m o Interlock _ Bonding location on Key side Bonding path ❑ ❑ - Leveling foot , o m I ❑ ❑ Bonding path IC I 1_7 '7 - ❑ ❑ I Bonding location on Module rotation during drop-in creates forced 1 1 Down-roof Tongue side interference between Zep Groove and spring clip. Down-roof cutting into module frame,removing anodization and resulting in robust and UL certified bonding path Document 800-1478-001 Rev A www.zepsolar.com PAGE: 3 of 5 Document 800-1478-001 Rev A wwwsepsolarcom PAGE: 4 of 5 ®2013/EN Zep Solar.Inc.Zep Solar reserves the right to make specifications on nages wi thout any prior notice.ALI rig hts reserved. ®2013/EN Zep Solar.Inc.Zep Solar reserves the right to make specifications chnages without any prior notice.ALI rights reserved. Date Last Exported:June 25,2013 4:45 PM Date Last Exported:June 25,2013 4:45 PM Zep Solar ZS COMP I GROUNDING AND BONDING Ground Zep Set screw /Key side The Ground Zep provides a single point of connection for the Equipment Grounding Conductor(EGC)from the array to a building ground. Ground wire channel Part No.850-1172 UL Listed to UL 467 and UL 2703 Ground Zep Installation 4 17 1 Insert Ground Zep into Zep Groove of module frame. Use the Flat Too to rotate the Ground Zep 90 degrees,so that set screw Insert copper EGC into ground wire on array perimeter is pointing straight up. channel.Tighten set screw using torque values shown in the ZS Comp Installa- tion Manual. Bonding Path - Array to Ground OGround Zep Equipment Ground Conductor Bonding path ( I 1Down-roof Document 800-1478-001 Rev A www.zepsoLar.com PAGE: 5 of 5 JW-2013/EN Zep Solar,Inc.Zep Solar reserves the right to make specifications chnages without any prior notice.All rights reserved. Date Last Exported:June 25,2013 4:45 PM SolarCity Standard BOX 4J NOTICE OF COMPLETION U AND AUTHORIZATION TO APPLY THE UL MARK The SolarCity Standard Box 4J is a • Manufactured to meet LIL 1741 Standards. 12/21/2013 4-String unfused Junction Box. The box . Non Metallic. Corrosion Resistant NEMA 4X Enclosure. SolarCity CorpAlex Yang is highly configurable and adaptable 3055 Clearview Way • Factory-Installed Cordgrip Enhances Installation Speed. San Mateo Ca 94402-3709,Us using the (4) jumper blocks included in each box. A factory installed Cordgrip • Break-Thru Skinned-Over Glands on Cordgrip Provide enhances installer productivity. Weathertight Seal for All Configurations. Our Reference: E318537,Volume 1 Project Number 4786083586 • Easily Configurable Terminal Blocks Permit Adaptation Your Reference: A.Yang 1017 Project Scope: Investigation of Photovoltaic(PV)System Combiner Box,model"SolarCity Standard Box 4C" to Site-Specific Stringing Needs. and Photovoltaic(PV)System Transition Box,model"SolarCity Standard Box 4X to UL 1741 Standard. Dear Alex Yang: Technical Data / Specifications Congratulations! UL's investigation of your product(s)has been completed under the above Reference Number and the product was determined to comply with the applicable requirements. This letter temporarily supplements the UL Follow-Up Services Procedure and serves as authorization to apply the UL Mark at authorized factories under UL's A Voltage Rating[VDC] 600V Follow-Up Service Program. To provide your manufacturer(s)with the intended authorization to use the UL Mark, you must send a copy of this notice to each manufacturing location currently authorized under E318537,Volume 1 B Maximum DC Current[A] 57A and including any special instructions as indicated in the addendum to this letter. w C O Maximum Continuous Current A:42A r►� [ J Records in the Follow-Up Services Procedure covering the product are now being prepared and will be sent in the D Maximum Voltage[VDCJ:600V near future. Until then,this letter authorizes application of the UL Mark for 90 days from the date indicated above. E Wire Size Range[AWGJ: #6 to#14 Additional requirements related to your responsibilities as the Applicant can be found in the document"Applicant responsibilities related to Early Authorizations"that can be found at the following web-site: �1-- F Enclosure Rating: NEMA 4X httD://www.ul.com/EAResponsibilities G Operating Temperature Range['Cj: -40 to 50 Any information and documentation provided to you involving UL Mark services are provided on behalf of UL LLC H Typical Overall Dimensions[in]: 8"x6'x4° (UL)or any authorized licensee of UL. We are excited you are now able to apply the UL Mark to your products and appreciate your business Feel free to contact me or any of our Customer Service representatives if you have any questions. r f 1 Very truly yours, Reviewed by: Jon Adonay William R.Carney 408-754-6630 847/664-1088 Engineering Associate Lead Chief Engineer Director I w Jon.Adonay@ul.com William.R.Carney@utcom O� NBKD9C5-90BA67 SolarCity® October 2013 This is an electronically generated letter Signatures are not required for this document to be valid- Page 1 of 1