HomeMy WebLinkAbout2021-0890 plans JURISIMMWCEMe Elsinore 1. LADDERS SI-RIWd0IW'31DEbWVC RED TO THE STRUCTURE FOR INSPECTION PURPOSES. GOVERNING CODES 2.fStjPffi RL0g CARR@2bQM ALARMS SHALL BE INSTALLED PER CRC R314-R315. ALL WORK SHALL CONFORM TO THE FOLLOWING CODES: 3.61�1601&Sjj 61262qIW916T.JtAA ff PAINTED TO MATCH THE EXISTING BACKGROUND MATERIAL COLOR OF THEIR LOCATION. 2019 CALIFORNIA BUILDING CODE 2019 CALIFORNIA RESIDENTIAL CODE hAh 2019 CALIFORNIA FIRE CODE 2019 CALIFORNIA ELECTRICAL CODE APPROVED SHEETINDEX PV 0.0 - COVER SHEET PV 1.0 - SITE PLAN S 1.0 - MOUNT DETAILS E 1.0 - ELECTRICAL DIAGRAM E 2.0 - ELECTRICAL NOTES E 3.0 -WARNING LABELS E 4.0 -WARNING LABEL LOCATIONS E 5.0 - BONDING DETAILS GENERAL ELECTRICAL NOTES GENERALSTRUCTURALNOTES v` Library Sr J 1.ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL 1.THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USING THE Library St MEANS DESIGNED AND LISTED FOR SUCH USE. FOR ROOF-MOUNTED SYSTEMS- ULTRARAIL RAILED SYSTEM BY SNAPNRACK. THE MOUNTING FEET ARE TO BE WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF THE ROOF SPACED AS SHOWN IN THE DETAILS-AND MUST BE STAGGERED TO ADJACENT SURFACE. FRAMING MEMBERS TO SPREAD OUT THE ADDITIONAL LOAD. 2.ANY CODE VIOLATIONS EVIDENT IN THE INTERCONNECTION PANEL WILL BE 2.UNLESS NOTED OTHERWISE SEE S 1.0-MOUNTING ANCHORS SHALL BE 5/161,LAG CORRECTED ON INSTALLATION. SCREWS WITH A MINIMUM OF 2-1/2"MIN PENETRATION INTO ROOF FRAMING. 3.SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH ALL RELEVANT CODE 3.THE PROPOSED PV SYSTEM ADDS 3.0 psf TO THE ROOF FRAMING SYSTEM 4.RAPID SHUTDOWN INITIATION TAKES PLACE WITHIN THE FIRMWARE OF THE 4.ROOF LIVE LOAD=20 psf TYPICAL-0 psf UNDER NEW PV SYSTEM. INVERTER. RAPID SHUTDOWN COMMENCES UPON LOSS OF UTILITY SOURCE 5.GROUND SNOW LOAD=0 psf VOLTAGE. 6.WIND SPEED=100 mph 5.SEE*E 1.0 AND*E 2.0 FOR DIAGRAMS-CALCULATIONS-SCHEDULE AND 7.EXPOSURE CATEGORY=C vivint.Solar _ 308 Line St, Lake SPECIFICATIONS A 5unrun COMPANY Elsinore,CA 92530,USA 1800 ASHTON BLVD.LEHI,UT,84043 1.877.404.4129 C CA LIC:973756 1 C-10&C-46 GC:CODY CRAM PHOTOVOLTAIC SYSTEM SPECIFICATIONS CAMPOS RESIDENCE SYSTEM SIZE - 15.62KW DC 114.444KW CEC AC 308 LINE ST LAKE ELSINORE,CA 92530 MODULE TYPE &AMOUNT- (44) UTILITY ACCOUNT:3-044-7321-19 LONGI LR4-60HPB-355M WITH SOLAREDGE P401 OPTIMIZERS METER:222011-761299 MODULE DIMENSIONS: (L/W/H) 69.1"/40.9"/ 1.4" INVERTER - (2) SOLAREDGE TECHNOLOGIES SE760OH-US AND SE380OH-US S#S-6603341 D\ / 0.0 ' ROC:CA-21 r V INTERCONNECTION METHOD (GRID-TIED): LOAD BREAKER DRAWN BY:DIN DATE:04/09/2021 REVISION:0 City of Lake Elsinore FIRE SETBACKS PV STRINGS: ROOF SECTIONS: SYSTEM LEGEND BUILDING DIVISION PV SYSTEM SIZE: Permit# BLDG 2021-0890 RIDGE:36" 1 PATHWAYS:36" ® PV STRING 1 =15 MODULES ROOF PLANE 1 SLOPE=17° (N)15.620kW DC 114.444kW CEC-AC Date: 05/19/2021 9:10:12 AM *1204.2 EXCEPTIONS:ROOF SLOPES<9.5°DO PV STRING 2-13 MODULES ROOF PLANE 1 AZIMUTH=12° NOT REQUIRE FIRE SETBACKS ROOF 1 MAT=COMPOSITION SHINGLE PAP, PV STRING 3=16 MODULES ROOF PLANE 2 SLOPE=14° ROOF PLANE 2 AZIMUTH=192° POINT OF INTERCONNECTION IN APPROVED ROOF 2 MAT=COMPOSITION SHINGLE EXISTING EXTERIOR MSP TIED TO UTILITY METER 222011-761299. ROOF PLANE 3 SLOPE=17° ° Q(N)PV SYSTEM AC DISCONNECT. ROOF PLANE 3 AZIMUTH=192 ROOF 3 MAT=COMPOSITION SHINGLE (N)DEDICATED PV SYSTEM COMBINER ©PANEL. ROOF PLANE 4 SLOPE=16° ROOF PLANE 4 AZIMUTH=286° (N)2 PV STRING INVERTERS: ROOF 4 MAT=COMPOSITION SHINGLE I SE7600H-US&SE3800H-US (N)44 LONGI LR4-60HPB-355M ROOF PLANE 5 SLOPE=16° MODULES WITH P400 OPTIMIZERS ROOF PLANE 5 AZIMUTH=106° MOUNTED ON THE BACK OF EACH ROOF 5 MAT=COMPOSITION SHINGLE MODULE. (N)JUNCTION BOX. (MOUNTED TO PV MODULE) O O p O o O U) -........- v /177777 O O 5 W /[if o Z LL oil O O ` J 6 z00 ............./� - 11 o . . .. .. .. . .. 3567 M 3i 2 Ex . ......... ......... ......... D \\Na I % CIVIL 1 R�� O I o ° 3 I I -: O U M Q Ci I I 1800 ASHTON BLVD.LEHI,UT,84043 1.877.404.4129 O I CA LIC:973756 1 C-10&C-46 GC:CODY CRAM CAMPOS RESIDENCE 308 LINE ST LAKE ELSINORE,CA 92530 UTILITY ACCOUNT:3-044-7321-19 ROOF FIRE SUPPRESSION SPRINKLER METER:222011-761299 " SYSTEM:NO SITE PLAN TOTAL ROOF AREA:2550 S#S-6603341 ' TOTAL MODULE AREA:867 ROC:CA-21 PV 1 .0 . SCALE: 1/8" = 1 -O° TOTAL AREA COVERED:34% DRAWNDATE:0 BY:DIN MAIN STRUCTURE IS 1 STORY(S)TALL. REVISION:0 City of Lake Elsinore MOUNTING NOTES BUILDING DIVISION Permit# BLDG 2021-0890 Date: 05/19/2021 9:10:13 AM gAg MUU LE, YP. ULTRA RAIL MID CLAMP SS SPLIT LOCK WASHER CONDUCTOR CONNECTS TO ANOTHER GROUND LUG ON m GROUND CONDUCTOR GROUND LUG R PRC BOTTOM RAIL OF ABOVE ROW OF MODULES BONDING CHANNEL NUT O MAX O UR-40 RAIL STANDOFF 4-3/8" SPEEDSEAL FOOT FILLED WITH ROOF SEALANT PER SPEEDSEALFOOT MANUFACTURER INSTRUCTIONS SHEATHING,TYP. 2-1/2 5/16"SS LAG SCREW, TYP. FRAMING,TYP. FRONT VIEW SIDE VIEW UR-40 RAIL SNAPNRACK ULTRA RAIL SPEEDSEAL FOOT 2 SNAPNRACK GROUND LUG R PRC MAX MOUNT SPACING NOT TO SCALE NOT TO SCALE LANDSCAPE MOUNT SPACING=72" LANDSCAPE CANTILEVER=24" PORTRAIT MOUNT SPACING=48" 'DEFER TO MODULE MANUFACTURER LIMITATIONS WHERE PORTRAIT CANTILEVER=16" THEIR MAXIMUM VERTICAL CANTILEVER IS SMALLER MAX MOUNT SPACING:SEE MID CLAMP,TYP. MOUNTING NOTES MAX 10"-16" CANTILEVER, CONDUIT TYP SPEEDSEAL FOOT,TYP. i I I CONDUIT SUPPORT `TTH MAX UR-40 RAIL,TYP. 101, CANTILEVER, CONDUIT MOUNT PRC3567 Z TYP ENDCLAMP,TYP. Exp. SS WATER TIGHT � SEALED SCREW j MODULE,TYP. C'V" i i I 1 I I I I MAX FRAMING,TYP.10"-16" vivint•Solar' CANTILEVER, MAX TYP 10" A Sunrun COMPANY CANTILEVER, 1800 ASHTON BLVD.LEHI,UT,84043 TYP 1.877.404.4129 CANTILEVER: CA LIC:973756 1 C-10&C46 SEE MOUNTING GC:CODY CRAM NOTES SNAPNRACK CONDUIT MOUNT DETAIL CAMP08LINEOS RESIDENCE SNAPNRACK MOUNT SPACING TYP. 308LINEST 3 LAKE ELSINORE,CA 92530 NOT TO SCALE NOT TO SCALE UTILITY METER::222011-7629921-19 MOUNT DETAILS 6603341 CA -21 ROC: S 1 .0 DRAWN BY:DIN SCALE: NOT TO SCALE DATE:04109/2021 REVISION:0 City of Lake Elsinore BUILDING DIVISION 2021-0890 Date: 05/19/2021 9:10:13 AM Photovoltaic System Conduit Conductor Schedule(Unless Otherwise Specified Conductors Shall be Copper) DC System Size (Watts) 15620 Tag Description Wire Gauge #of Conductors/Color Conduit Type Conduit Size AC System Size(Watts) 14444 1 DC-to-DC Converter Output(PV Wire) 12 AWG 2(V+,V-)B/R Free Air N/A om N Ln Total Module Count 44 1 EGC(Bare) 6 AWG 1 BARE Free Air N/A U N r, APPROVED 2 DC-to-DC Converter Output(THWN 2) 12 AWG 4(2V+,2V)B/R EMT 1/2" N U o LU 2 EGC(THWN-2) 12 AWG 1(GRN) EMT 1/2" v zZi m 3 DC-to-DC Converter Output(THWN-2) 12 AWG 2(V+,V-)B/R EMT 1/2" o 00 c 3 EGC(THWN-2) 12 AWG 1(GRN) EMT 1/2" w 4 Inverter Output(THWN-2) 8 AWG 3(L1,L2,N)B/R/W EMT 3/4" v Q 4 EGC(THWN-2) 10 AWG 1(GRN) EMT 3/4" +� 5 Inverter Output(THWN-2) 12 AWG 3(L1,L2,N)B/R/W EMT 1/2" 5 EGC(THWN-2) 12 AWG 1(GRN) EMT 1/2" 6t Inverter Output(THWN-2) 12 AWG 3(L1,L2,N)B/R/W PVC 1" 6t EGC(THWN-2) 12 AWG 1(GRN) I PVC 1" 7 Inverter Output(THWN-2) 6 AWG 3(L1,L2,N)B/R/W EMT 3/4" 7 1EGC(THWN-2) 10 AWG 1(GRN) EMT 3/4" C3 Z Z !^^ CL vJ � O Sol a rEdge SE380OH-US U c C 61M � C N Ol Q Square D v DU221RB, v 240V/30A, u Unfused, NEMA3R STRING 3:16 PV 1 2 16 rn � MODULES N W/OPTIMIZERS 06 � o cc 3 ^ v < o^o — 16 PV MODULES PER INVERTER=5680 WATTS �- ri kD STC Sol a rEdge SE760OHUS OLn F— w rn z � � Point of Interconnection,Load > Square D DU222RB, Side 705.12(B)(2)(3)(b) > z in 240V/60A,Unfused, w w M 20A NEMA3R Q Q O m T m L1 L2N Existing Eaton N N -0 o 240V/225AService Panel, z z U QD STRING 2:13 PV 1 2 13 40A Single Phase,with 100A SHEET MODULES Main Disconnect-NOT A W/OPTIMIZERS CENTER FED- NAME: n Main Disconnect is Rapid 2 \ 100 Shutdown Disconnect = �� 13 STRING 1:15 PV 1 2 15 Combiner Panel 125A/240V,Square D J i MODULES NEMA 3R Junction Box HOM48L125GRB 7 A W/OPTIMIZERS 4 Minimum GEC size 60A SHEET AWG copper NUMBER: 28 PV MODULES PER INVERTER=9940 WATTS tConduit to be installed in trench no STC less than 18" below grade, top of Visible/Lockable'Knife'Ac Disconnect conduit W City of Lake Elsinore BUILDING DIVISION 2021-0890 D s PV Module Rating @STC Conductor Calculations Optimizer SolarEdge P401 Module Make/Model Longi LR4-60HPB-355M o Wire ampacity calculated from 310.15(B)(16) & (17) as appropriate with ambient temperature a) Ln m DC Input Power 400 Watts Max. Power-Point Current(Imp) 10.27 Amps u N r` calculations from 310.15(B)(2)(a) & 310.15(B)(3)(c) and raceway fill adjustments from 310.15(B) o, DC Ma . I 60 Volts Max. Power Point Voltage(Vmp) 34.6 Volts (3)(a). Conduit on the roof shall be installed no less than 1" above the roof deck. _0 N u o DC Max. nput urrent 14.65 Amps Open-Circuit Voltage(Voc) 40.6 Volts v z ai PV Circuit conductor ampacity is constrained using the 75°C column with the continuous duty - DC Max.Output Current 15 Amps Short-Circuit Current(Isc) 11.25 Amps uprating or the 90°C column with the relevant ambient temperature and raceway fill adjustments o o 0 Max.string rating inverter dependent.See SE documents. Max.Series Fuse(OCPD) 15 Amps without the continuous duty uprating per 690.8(B), whichever results with a larger wire size. E o w U Inverter Make/Model SolarEdge SE760OH-US Nom.Max. Power at STC(Pmax) 355 Watts Non-PV Circuit conductors use the ampacity in the 75'C column or the 90°C column with the u Q CEC Efficiency 99 % Max.System Voltage 1000 VDC relevant ambient temperature and raceway fill adjustments, whichever is less (110.14(C) & AC Operating Voltage 240 Volts Voc Temperature Coefficient -0.27 %/C 310.15(A)(2)).The rating of the conductor after adjustments shall be greater than, or equal to, Z) Cont.Max Output Current 32 Amps the continuous duty uprated current. DC Max Input Current 20 Amps ASHRAE 2017-MARCH AFB More information about conductor calculations can be provided upon request. Input Short Circuit Current 45 1 Amps Highest Monthly 2%D.B. Design Temp.:38.7°C Calc. Ex: Wire Ampacity x Ambient Temp. Corr. Factor x Conduit Fill Adj. Factor>= Output Current Lowest Min. Mean Extreme D.B.:-6.5`C (Tag 1 Under Array): Max Output Fault Current 40 A/ZO ms Inverter 2 Make/Model SolarEdge SE3800H US DC-to-DC Converter Output: 12 AWG rated 20 A, 20 A>= 18.75 A L Z (Tag 2 On Roof): � CEC Efficiency 99 % Power Source(s) Output Calc: 705.12(13)(2)(3)(b) DC-to-DC Converter Output: 12 AWG rated 20 A, 20 A>= 18.75 A O AC Operating Voltage 240 Volts (Tag 3 On Roof): Cont.Max Output Current 16 Amps Main Bus Rating: 225 Amps DC-to-DC Converter Output: 12 AWG rated 20 A, 20 A>= 18.75 A } 0 DC Max Input Current 10.5 Amps Main Service Breaker Rating: 100 Amps (Tag 4 Exterior): C Input Short Circuit Current 45 Amps PV Breaker Rating: 60 Amps Inverter Output: 8 AWG rated 50 A, 50 A>=40 A •� ` 100A+ 60A<= 225 x 1.2; 160<= 270A, OK (Tag 5 Exterior): > C Max.Output Fault Current 17.5 A/20 ms � Inverter Output: 12 AWG rated 20 A, 20 A>= 20 A N 4 (Tag 6 In Trenched Conduit): ' Q Inverter Output: 12 AWG rated 20 A, 20 A>= 20 A Voltage Drop across Trench 6 is 1.58% v (Tag 7 Exterior): u Inverter Output: 6 AWG rated 65 A, 65 A>= 60 A N � Other Notes v 0 0 • Designed according to and all code citations are relevant to the 2019 California Electrical Code. • Inverter(s) used in this design is/are compliant with 690.12 (Rapid Shutdown). See manufacturer data sheet. C)f Ul Q o0 • All inverters installed in California are Rule 21 Utility interactive compliant. o _1Ln • Array grounding and bonding designed in compliance with 690.47(A). Un w ro • Electrical terminations and connectors used in design are listed for use at a minimum of 75°C z CO Voltage and OCPD Calculations (690.7, 690.9) '> z E PV Source Max Circuit Voltage: Module Voc x (1-(AT x Voc Coeff)) [art. 690.7(A)] J J O LR4-60HPB-355M:40.6 V x (1-((25 C--6.5 C) x -0.27%)) =44.05 V<= 60 V N N -M o z z � Inverter Output Circuit(s): Listed Output Current x 1.25 [art. 690.9(B)] SHEET Inverter 1:SE760OH-US Max Output= 32 A x 1.25 =40 A<=40 A(OCPD) NAME: Inverter 2:SE380OH-US Max Output= 16 A x 1.25 = 20 A<= 20 A(OCPD) System output current w/continuous duty= 60 A<= 60 A(System OCPD) O bn Z a SHEET NUMBER: N W City of Lake Elsinore BUILDING DIVISION 2021-0890 Date: 05/19/2021 9:10:13 AM All AC Disconnecting Means-AC Disconnect(s), Invert e isconnect per 53 Installed within 3 ft of Rapid Shutdown Switch, Reflective,and shall be Combiner Panels,and Load Centers per 690.54 °r,' Conduit, Raceways, and J-Boxes(Labeled Every 10) and placed on both Panel Exterior& next to Main Disconnect perPHOTOVOLTAIC • o N • 480 V Reflective per 690.31(G)(3) &(4) Ln m WARNING:MAXIMUM PHOTOVOLTAIC • c� N r` • • • • • 48A O1 � 20A u o POWERSOURCE • ' 240V vz vM J N 00 o Z3 MAX RATED • • a o '�, o THE CHARGE CONTROLLER PV System Disconnects per 690.13(B) PV with Rapid Shutdown Switch, Installed within 3 ft of Service Disconnecting E "' w tu) ro OR DC-TO-DC CONVERTER: 15 A • Means with min. 3/8" black capitalized text on yellow background& 3/16" " J • SYSTEM DISCONNECT black capitalized text on white background per 690.56(C)(1)(a) SOLAR PV SYSTEM EQUIPPED Inverter 2 DC Disconnect per 690.53 WITH RAPID SHUTDOWN MAXIMUM • 480 V MAXIMUM CIRCUIT CURRENT: 10.5 A _C3 z TURN RAPID SHUTDOWN 0 a- MAX • OUTPUT • SWITCH TO THE SOLAR ELECTRIC � • • •LLER "OFF" POSITION TO PV PANELS 0 THE CHARGE C • ' DC-TO-DC • 15 A SHUTDOWN PV SYSTEM ~ C (IF INSTALLED) AND REDUCE SHOCK HAZARD C N IN ARRAY Plaque/Directory at Service Equipment Location and Power Production System Q e v All Disconnecting Means-AC& DC U CAUTION: MULTIPLE • OF POWER Disconnect(s), Load Centers,and Combiner 1 WER ' ■ ' t PPLIE ' � ' Panels per 690.13(B) &690.15(D) o, • M TV AWARNING FOLLOWING RC �Is i � � ­I ♦ ELECTRICAL SHOCK HAZARD rz u r` „• 00 — ♦ • TERMINALS ON THE LINE AND Q ri � ' LOAD SIDES MAY BE ENERGIZED i r` IN THE OPEN POSITION z COUJ ♦ >_ 2 U ♦ ♦ > Z J Power Source Output Connection,Adjacent L = E ��►��� ♦ 0 to Back-fed Breaker per 705.12(B)(2)(3)(b) J J E 0 M �:�c���' • ' ►-• o AWARNING z z kD ��•yr.L • RAND MAIN` ►=, POWER SOURCE OUTPUT CONNECTION SHEET ♦ DO NOT RELOCATE NAME: ♦ ' === ♦ THIS OVERCURRENT PROTECTION DEVICE co DISCONNECT Dual Power Sources in Main Service Panel and Sub Panel(s) per 705.12(B)(3) • SIGNS/LABELS SHALL MEET THE REQUIREMENTS OF ARTICLES 690 AND 705, UNLESS OTHERWISE SPECIFIED PER f° M a II ♦ ' DISCONNECT O AWARNING LOCAL AHJ REQUIREMENTS • SIGNS/LABELS SHALL MEETTHE REQUIREMENTS OF SECTION 110.21(B)AS REQUIRED PER ARTICLES 690 AND 705 AND SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS • SHEET DUAL POWER SOURCE SIGNS/LABELS SHALL BE REFLECTIVE IF REQUIRED TO BE SO PER ARTICLE 690 • SIGNS/LABELS MEETING NUMBER: ♦ ♦ REQUIREMENTS OF ARTICLE 690 SHALL HAVE NO SMALLER THAN 3/8"WHITE TEXT ON RED BACKGROUND UNLESS SOURCES; UTILITY GRID OTHERWISE DEPICTED OR DESCRIBED • SIGNS/LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR AND PV SOLAR ELECTRIC SYSTEM WIRING METHOD AND SHALL NOT BE HANDWRITTEN • SIGNS/LABELS SHALL BE OF SUFFICIENT DURABILITY TO M WITHSTAND THE ENVIRONMENT INVOLVED • SIGNS/LABELS SHALL NOT COVER EXISTING MANUFACTURER LABELS LJ City of Lake Elsinore BUILDING DIVISION Date: 05/19/2w§'WY�Lklml ***V WARNING **A SITE PLACARD SHOWING ADDITIONAL POWER SOURCE RAPID SHUTDOWN SWITCH DUAL POWER SOURCE MAX13�bUTPUT CURRENT OF 4 7 AND DISCONNECT LOCATIONS. PLACARD SHALL BE 10 o N FOR SOLAR PV SYSTEM SOURCES: UTILITY GRID rn THE CHARGE CONTROLLER OR DC-TO-DC ***A MOUNTED ON EXTERIOR OF ELECTRICAL PANEL AND PV SOLAR ELECTRIC SYSTEM c r, (I ED) N Uw O n WARNING MAIN BREAKER DE-RATED = z SOLAR PV SYSTEM EQUIPPED TERMINALS ON THE LINE AND DUE TO SOLAR CIRCUITS o � 2 WARNING: PHOTOVOLTAIC POWER SOURCE S $ 11 0- 0 '7, ° WITH RAPID SHUTDOWN LOAD SIDES MAY BE ENERGIZED ***AMPS MAX ALLOWED E ``� w u IN THE OPEN POSITION DO NOT UPGRADE J j-+ WARNING � PHOTOVOLTAIC AC DISCONNECT POWER SOURCE OUTPUT CONNECTION 3 PV SYSTEM DISCONNECT 6 MAXIMUM AC OUTPUT CURRENT: ***A 9 DO NOT RELOCATE NOMINAL AC OPERATING VOLTAGE: ***V THIS OVERCURRENT PROTECTION DEVICE C3 z ROOFTOP ARRAY O Q O 5 } Crj N rj 7 11 IF APPLICABLE �' Q 1 4 6 8 INSIDE 10 6 N PANEL v co 2 0 0 3 8 6 8 6 8 6 8 10 9 9 8ul EVERY 10'AND °o �° O Ln WITHIN 1' OF ELBOWS y lCl� w F z CO rn > > J 9A°� DC M 6 E 2 �`v', DISCONNECT M Q Q 0 m INSIDE z zfl SHEET COMBINER PANEL VISIBLE/LOCKABLE A/C VIVINT SOLAR METER VISIBLE/LOCKABLE A/C SUB PANEL MAIN SERVICE NAME: ROOFTOP SOLAR INVERTER JUNCTION BOX 2 (WHEN USED) DISCONNECT(WHERE (WHERE REQUIRED) DISCONNECT (WHEN REQUIRED) DISCONNECT PANEL c REQUIRED) = H i OJ GJ *** -value calculated for each M TYPICAL SOLAR GENERATION INSTALLATION account,for specific value see the a. (NOT ALL DEVICES ARE REQUIRED IN EVERY JURISDICTION) previous warning label page SHEET NUMBER: • SIGNS/LABELS SHALL MEET THE REQUIREMENTS OF ARTICLES 690 AND 705, UNLESS OTHERWISE SPECIFIED PER LOCAL AHJ REQUIREMENTS • SIGNS/LABELS SHALL MEET THE REQUIREMENTS OF SECTION 110.21(B)AS REQUIRED PER ARTICLES 690 AND 705 AND SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS • SIGNS/LABELS SHALL BE REFLECTIVE IF REQUIRED TO BE SO PER ARTICLE 690 • SIGNS/LABELS MEETING REQUIREMENTS OF ARTICLE 690 SHALL HAVE NO SMALLER THAN 3/8"WHITE TEXT ON RED BACKGROUND UNLESS OTHERWISE DEPICTED OR DESCRIBED • SIGNS/LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HANDWRITTEN • SIGNS/LABELS SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED • SIGNS/LABELS SHALL NOT COVER EXISTING MANUFACTURER LABELS W City of Lake Elsinore — NOTES BUILDING DIVISION MODULE FRAME Permit# BLDG 2021-0890 Date: 05/19/2021 9:10:13 AM U*71�RA RAIL END CLAMP MODULE ULTRA RAIL MID CLAMP UL2703:2015 LISTED BONDING CLIP BONDS SOLAR MODULE FRAME TO OPTIMIZER OR MICRO-INVERTER UR-40 RAIL NOTE: E-W BONDING IS ACCOMPLISHED OPTIMIZER MOUNTED WITH 2 PRE-INSTALLED BONDING PINS TO MODULE FRAME SEE DETAIL #3 WITHIN THE MID-CLAMPS. FOR E-W BONDING PATH (:ONOTND/MID-CLAMP BONDING WITH UL2703 TO SCALE OPTIMIZER BONDING TO EGC � G DETAIL WITH UL2703 2 NOT TO SCALE UR-40 RAIL MODULE or TO EGC Lr UR-40 RAIL GROUND LUG R INCLUDING BONDING CHANNEL NUT SEE DETAIL #3 vivint.Solar O GROUNDING LUG (SEE S1.0 DETAIL #2) FOR N-S BONDING PATH A sunrun COMPANY 1800 ASHTON BLVD.LEHI,UT,84043 N-S BONDING PATH a MID/END CLAMP MODULE JUMPER BONDING WITH UL2703 CALIC19737561C10&C-46 GROUND LUG TO GROUND LUG. SEE o E-W BONDING PATH, RAIL 4 NOT TO SCALE GC:CODYCRAM �-- DETAIL #4 CAMPOS RESIDENCE SPLICE. SEE DETAIL #1 308 LINE ST E-W BONDING PATH, MID-CLAMP. SEE LAKE ELSINORE,CA 92530 DETAIL #1 UTILITY ACCOUNT:3-044-7321-19 METER:222011-761299 SYSTEM BONDING LAYOUT WITH UL2703 BONDING DETAILS ROC:S-660331 E 5.0D 3 NOT TO SCALE DRAWN BY:DIN SCALE: NOT TO SCALE DATE:04/09/2021 REVISION:0