Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
TRAFFIC SIGNAL PLAN TR 25479 - HWY 74 AND ROSETTA CNYN
P O L E S C II E D U L E espy- 1 n ' 90• "1 L STANDARD ARMS LUMINAIRE PED PUSH BT. SIGNAL MOUNTING 1.1.S.N.S. PLACEMENT CONSTRUCTION NOTES: uf °y L1-2_u C TYPE HT, SIG. LUM. H.P.S.V. TYPE WSE QUAD VEHICLE PED. MESSAGE A B ❑1 INSTALL STATE FURNISHED (PURCHASED FROM STATE) MODEL 170E CONTROLLER ASSEMBLY AND 332 CABINET PER STANDARD A 26-4-161 30' 45' 15' 200 W - - - 2-MAS, SV-2-T - • Rosetta Canyon Drive 64' 3'0PLANS ES-3C. CONSTRUCT FOUNDATION PER.STANDARD PLAN ES-46. BATTERY BACKUP SYSTEM CABINET (PURCHASED FROM S 2 -4-161 30' 45' CAP - 4 N MAS,sv-2-T SP-1-T • Hichway 74 q5' 4' STATE) IS CONTRACTOR FINISHED. INFORMATION ON A LIST OF STATE APPROVED VENDORS IS AVAILABLE IN CALTRANS WEBSITE. n riert' seePI.,ES-ap 26-4-161 30, 40' 15, 200 W B 4 S MAS,SV-1-T SP-1-T • Rosetta"an on Drive 22' 4' ❑2 INSTALL TYPE III CF SERVICE Will' 120V/240V SERVICE, 100M MAIN BREAKER. SIGNALS SHALL BE METERED WITH A 50A BREAKER ; y FOR SIGNALS, 15A BREAKER FOh IISNS. SAFETY LIGHTING SHALL BE METERED WITH A 30A BREAKER. „lie„eEe4°n,e DD 1A 10' - - - B 2 W TV-1-T SP-1-T - 25' 3' [] INSTALL 3" CONDUIT WITH PULLROPE TO EDISON SERVICE POINT. E 61-5-161 30' 1 CAPA 15' 200 W B 2 W - SP-1-T 2 3' Q INSTALL 2"C, 6 PAIR #20 SIC. IA 10' - - - - - - Tv-2-T - - 22' 3'-1 ' 05 INSTALL SIGN PER CALTRANS STDS. ON MAST ARM. SILIE MOUNTED LEFT TURN © 15TS 30, - - 200 W - - - SV-1-T - - 22' 3' © NEW SERVICE POINT. SIGFI41_S cSv AP- Sp) _AHE SIGNAL Tppe -s, e, i c orrd-l-6 sm"a°ra r:or„°`liy°eeu • CITY Loco EXACT POLE LOCATIONS DETERMINED BY ENGINEER IN THE FIELD. 07 INSTALL 3M MODEL 711 OPTICOM DETECTOR 3M MODEL 138 DETECTOR CABLE AND 3M MODEL 752 RACK e pl°"' 65' FUTURE MAST ARM. POTHOLE POLE FOUNDATION LOCATIONS PRIOR TO ORDERING POLES. MOUNTED PHASE SELECTOR EQUIPMENT, SEE DETECTOR MOUNTING DETAIL THIS SHEET. ® INSTALL R96 & R96A SIGNS ON POLE. TYPICAL SIGNAL INSTALLATIONS ❑9 INSTALL R61-19 PER CALTRANS STDS. ON MAST ARM. ADDREVIATIOI,. P. —LT = Left turn .,,. (19.8M) -_ 64' 45' F!, .I,- H I G (19.5M) (13.7M)H VI/A Y 74 .P. �2 A.C.PAD 6 E6 6/`/ 1 2C,4 DLC 2 DLC 2 2 DLC � B 60 P. C 3 -- -- - - ---__FFF5 --�N------...-----------------:— _-- — — ��143 CdrG C&G _ ----IT 11NE -------- -- Z�zu o Tn ------- --- 3 ——I —06 04 Detail'B 04 zL LIMIT u� _ -__TV - -- -- -- - -N -- -- - - -- Tcl\ ..-a�_ M _ - ®R73 3 6J2U �►1 - - -�— 14e - - - - 4s M - - 150 200' TO se 4 5 Tr r I 2/3U l I 1HuOe ♦ 11sU - - LIMIT LINE_ LfM1T 7 R3-18 _ M ^M N= I I 02 -- -- -- -- -- -- -'__ ... — _ &G 7 -..—_ O� _2 C,3 DLC i C.&G. - ..'�..,,._1 �� bey. f— o 2"C,4 DLC �►�."�` --_ - -.._-,_�- - _ _ --- --- - -- --- - .....-- -- — TO ARDENW00D WAY --- -- -- - _ ---- - -- --_.__ _ �, � 6 _._-_-__._._- ----- _ _- _ _ 02eI, INTERSECTION ----- -._ _ - - '-- - j• ,�._ - "-� 6-OF .P-- -- FROM CC TO CL _ ------ -�� I --_- nPP4CX.950' -- --_._- ��_ � �� —� � R=50' .© � _T CONDUIT SIZE AND RUN r - -r-- 4 , - - -- -- -- - -- -- -—- -�- _ CONDUCTOR SCHEDULE - _��-_� f` I _ E 6x,D HIG HW,�Y 74 AWG SIZE POLE OR 3 3° 3 4' 4 4° 4' 4' 8 r I— L INTERSECTION APPROX. 2600' [31TO TRELLIS LANE— OR _ �6 CABLE TYPE CIRCUIT Q 2 3 4 5 6 7 NOTE: 7 D/ 5 FROM CL TO CL N], 14 CABLES POLE - A _ --- 1 - 1 - -- -- 1 - 1 ALL SECTIONS 12" 8 2",4#10 4f,12 41 U 418L y__ ' I I/ � C B - _ 1 1 1 - -- - 1 1 ' �4 INSTALL 2"G, _ - _;. GENERAL NOTES: 0 D - - - I i 2"C,4 DLC N N C - - - - 1 1 1 1 . 2-6 PAIR SIC I �� �-- D - - - 1 1 1 U 3 U E - - -- -- -- - 1 1 " �t 3 = I ® 1. ALL WORK MATERIAL AND EQUIPMENT DONE WITHIN STATE RIGHT-OF-WAY SHALL CONFORM TO THE STATE _ _ •/ - -_- I OF CALIFORNIA, DEPARTMENT OF TRANSPORTATION, 1999 STANDARD SPECIFICATIONS AND 2004 STANDARD PLANS C C - - i 2"C,36(SERVICE) �- e F _ - - 1 - - 1 1 __ AND THIS PROJECT SPECIAL PROVISIONS. PLEASE SEE THIS WEB ADDRESS FOR REVISED JULY 2004 STANDARD I0 12 0 c _ t _ t _ 1 _ t _ -_ -_ t _ t O -5 _ I �- PLANS: http://www.dot.ca.gov/hq/esc/oe/project-plans/HTM/stdpins-met-new04.htm P. R - - - - - - - - i 1 2. UTILITIES SHOWN ON THESE PLANS ARE CORRECT AND ACCURATE TO THE EXTENT S S C.&G. OF AVAILABLE RECORDS ID KNOWLEDGE. THE CONTRACTOR, HOWEVER, IS REQUIRED TOTAL CABLES-3 CONDUCT,/12 CONDUCT,- t © G I TO ASCERTAIN THE EXACT LOCATION OF UNDERGROUND FACILITIES PRIOR TO DOING 10 LIGHTING 2 2 2 2 2 2 4 - 1 I ® WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICE. 12 ❑SNS - 2 2 2 2 2 4 - C G. I 3. THE CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS AND NOTIFY ALL UTILITY 6 SIGNAL SERVICE - - - - - - - - _ COMPANIES A MINIMUM OF. 48 HOURS PRIOR TO START OF CONSTRUCTION, IT SHALL „ „ I, , U BE THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE ALL PHASES OF TYPE 'B' DLC 01 LOOP LEAD-IN 2 2 2 2 - - 2 2 DETAIL B I 411E I I CONSTRUCTION WITH THE VARIOUS UTILITY COMPANIES INVOLVED. TELEPHONE SERVICE 02 - - - 6 - - 6 6 98M' , 2' 1 , 12, 20 I SHALL BE READY BEFORE THE SIGNAL TURN ON. 04 - - - - - 6 6 6 M 3•M 3.7M 6.1M I 4. THE ENGINEER SHALL APPROVE THE EXACT LOCATION OF ALL PULLBOXES, os 4 a 4 a - - 4 a PHASE DIAGRAM CONDUITS, DETECTOR LOOPS, AND POLES IN THE FIELD. TOTAL s s G I2 - s IB 18 GROUP A GROUP B I ` W. I < 5. ALL PULLBOXES SHALL Br: No. 5 UNLESS OTHERWISE NOTED ON PLAN. EVP CABLE - 1 2 2 1 1 3 3 I STANDARD PLACEMENT DETAIL 6 PAIR N20 - - - - - - - - I 2"C,3 DLC 6. ALL CONDUIT SHALL BE 53C UNLESS NOTED OTHERWISE NOT i I I Q 7. NO LIGHTING CONDUCTOR`; SHALL ENTER THE CONTROLLER CABINET. a -A --- USED f 418U I I 8. INSTALL 1 #8 CONDUCTOR IN CONDUIT CONTAINING POWER CONDUCTORS AND I B 1 #10 CONDUCTOR IN CONDUITS CONTAINING DLC, I.C., OR TELEPHONE CABLE. T PHASE 1 PHASE 2 PHASE 3 PHASE 4 9. ALL CONDUCTORS SHALL BE NFW UNLESS OTHERWISE NOTED ON PLAN. UNDERGROUND STRUCTURES d ALL UND¢RGROUND UTILITIES OR STRUCTURES REPORTED BY THE OWNER OR OTHERS AND THOSE SHOWN a NOT w A ON THE RECORDS EXAMINED ARE INDICATED WITH THEIR APPROXIMATE LOCATION AND EXTENT.THE OWNER NOT �_ NOT �O 2"C�2 DLC + B.C.R. BY ACCEPTING T14ESE PLANS OR PROCEEDING WITH IMPROVEMENTS PURSUANT THERETO AGREES TO ASSUME Z USED USED USED / o A I LIABILITY A i4 'D HOLD UNDERSIGNED HARMLESS FOR ANY DAMAGES RESULTING FROM THE EXISTENCE OF I UNDERGROUND UTILITIES OR STRUCTURES NOT REPORTED TO THE UNDERSIGNED:NOT INDICATED ON THE o PUBLIC RECORDS EXAMINED:THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PhiASE 5 PHASE 6 PHASE 7 PHASE 8 / r , (LXACT LOCATION BY ENGINEER IN THE FIELD) n PROTECT THE UTILITIES OR STRUCTURES SHOWN AND ANY OTHER UTILITIES OR STRUCTURES FOUND AT THE SITE. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE OWNERS OF THE UTILITIES OR U STRUCTURES CONCERNED BEFORE STARTING WORK. r / /� / 417 416L �/ SCALE: 1 = 20' NOTE THIS PLAN ACCURATE FOR ELECTRICAL WORK ONLY / — — — — 0 10' zo' ao' so' ao' PERMIT #08 04 6 MC 0989 VISIONS: o SEAL-ENGINEER SEAL-ENGINEER pRgp PREPARED BY: CITY OF LAKE ELSINORE z THESE PLANS HAVE-4ERT OFESS1p J �� 0� 411 Avenida Encinas WITH THE PPROPRIATTEECONDITONS OF DEVELOPIANCEMENT y�vo-S��SON pq/�"y�, CARLETON WATERS,R.C�.12 1 Oe DA Cm1e 10o TRAFFIC SIGNAL PLAN 2 DIG /?/ ccAsbca a s2ooe OF DIAL TWO WORKING AND/OR CITY AND STATE LAWS, AND A PERMIT v c� i" n URSAN Phone:1760)931-0664 TRACT NO. 25479 4 a BEFORE DAYS BEFORE r A m Fax: j780 931-1741 a YOU DIG YOII DIG CA BE ISSU D. °� u No.52916 H '° THESE PLANS HAVE BEEN REVIEWED FOR COMPLIANCE WITH MARK DESCRIPTION BY APPR. DATE * Exp..12/31/06 * THE APPROPRIATE CONDITIONS OF DEVELOPMENT AND/OR SHEETS 1 TOLL FREE 1-800-227-2600 KEA/ A. SEK"AA[e /.� o rrr CI VR �� CITY AND STA LAWS. A PERMIT CAN BE ISSUED. SCALE: 1"=40' PR:}'ARED FOR: CENTEX HOMES o A PUBLIC SEANCE BY DESIGNED BY: JT DFlAWTa BY: JT R934i T•-+.f--M9EHN#6, CITY ENGINEER DATE °rt of cALltoa� - +� 1295 CORONA POINTE W.O. FOR' F.B. FILE NO. UNDERGROUND SEIIMCE ALERT RCE#e05fr SE[xµA[o cY41S CORONA,CA 92879 01578 CENTER IIOMES CHECKED BY: CW PROJECT MANAGER: BW DATE: 1-05-2005 Sd4lY REtBERTK MOEHIiNO RCE/43eW (951)479-9300 .ifs s raiKi