Loading...
HomeMy WebLinkAboutOhana Cir_29910_102-SOCALRVDOCTOR (002) RIVERSIDE COUNTY FIRE DEPARTMENT CITY of OFFICE OF THE FIRE MARSHAL LADE L LSINORI ,'1 CITY OF LAKE ELSINORE ` DREAM EXTREME .' 130 S. Main St. • Lake Elsinore, California 92530 (951) 674-3124 Ext. 225• Spayne(aLake-Elsinore.Org Building Address: 29910 Ohana Circle Business Name: SoCal RV Doctor Owner/Manager Name: Curtis Labeda Inspected by: Ronnie Morales Date of Inspection: 12/22/2021 Email: curtisl(a)socalrvdoctor Permit: N/A Phone: 951-471-3840 A fire safety inspection of was performed at the property at 29910 Ohana Circle, on December 22, 2021, shows the following violations of the code of ordinances of the City of Lake Elsinore: Item Code Inspection Observation Recommended Action Date Completed 01 Title 19 Documentation for the annual Inspect,test, and maintain of the 904 inspection,testing, and fire sprinkler system in accordance maintenance of the fire sprinkler with Title 19. Provide a current copy system was not available. of the annual fire sprinkler system inspection test report to the fire de artment. 02 Title 19 Documentation for the 5-year Inspect,test, and maintain the fire 904 inspection,testing, and sprinkler system in accordance with maintenance of the fire sprinkler Title 19. Provide a current copy of system was not available. the 5-year fire sprinkler system inspection test report to the fire department. 03/14/2022: (1)Contractor failed 03/14/2022: Have contractor to perform back flus of the FDC. perform backflush and internal pipe (2)Contractor failed to perform 5- inspection and resubmit the report year internal pipe inspection. to the fire department. 03 CFC Documentation for the annual Inspect,test, and maintain the fire 907.8.5 inspection,testing, and alarm system in accordance with maintenance of the fire alarm NFPA 72. Provide a copy of the fire system was not available. alarm test report to the fire department. 04 CFC Documentation for the annual and Inspect,test, and maintain the fire 507.5.3 5-year inspection, testing, and hydrant(s)in accordance with Title maintenance of the fire hydrant(s) 19. Provide a current copy of the was not available. annual and 5-year fire hydrant inspection test report to the fire de artment. 05 CBC 04/06/2022: Identified the building Apply for a building permit due to was modified without a building the modifications to the building. permit.Areas were not protected with automaticsprinklers. 06 CFC 04/06/2022: Sprinkler system was Apply for a fire permit due to the modified without a fire permit. modification to the fire sprinkler system. 07 NFPA 13 04/06/2022: Identified a high Provide documentation that the fan 11.1.7 volume low speed fan (HVLS)in was installed as follows: the gym. Unknown if the fan was 1. Maximum fan diameter shall be 24 feet. Page 1 of 2 RIVERSIDE COUNTY FIRE DEPARTMENT CITY OF OFFICE OF THE FIRE MARSHAL LADE LSINOR E CITY OF LAKE ELSINORE ` DREAM EXTREME .' 130 S. Main St. • Lake Elsinore, California 92530 (951) 674-3124 Ext. 225• Spayne(aLake-Elsinore.Org Item Code Inspection Observation Recommended Action Date Completed installed in accordance with NFPA 2. The HVLS fan shall be 13. centered approximately between four adjacent sprinklers. 3. The vertical clearance from the HVLS fan to sprinkler deflector shall be a minimum of 3 ft. 4. All HVLS fans shall be interlocked to shut down immediately upon receiving a waterflow signal from the alarm system in accordance with the requirements of NFPA 72. Correction of these deficiencies must be made immediately upon receipt of this notice. An inspection to determine whether the deficiencies have been corrected shall occur by the close of business on or about January 22, 2022. Please feel free to contact me if you have any questions. Sincerely, Ronnie Morales, Fire Systems Inspector Office of the Fire Marshal CalFire/ Riverside County Fire Bus: 951-674-3124 x279 Page 2 of 2