Loading...
HomeMy WebLinkAbout0003_6_PA 2021-26 - Exhibit E - Design Review PackageHV LV HV LV HV LV HV LV HV LV HVLVHVLVAPN 377200046APN 377200047APN 377200045APN 377110046RV STORAGE FACILITYAPN 377350021SPYGLASS RANCHSPECIFIC PLAN AREAAPN 347250010LEGENDVICINITY MAPDrawing No.ScaleRevisionTitleProject No.SheetofORIGINAL SHEET - ANSI Dwww.stantec.com200 East Carrillo Street, Suite 101Santa Barbara, CA 93101ConsultantsClient/ProjectThe Contractor shall verify and be responsible for all dimensions. DO NOT scale thedrawing - any errors or omissions shall be reported to Stantec without delay.The Copyrights to all designs and drawings are the property of Stantec. Reproductionor use for any purpose other than that authorized by Stantec is forbidden.\\us0377-ppfss01\workgroup\1858\active\185805133\03_data\CAD\Ortega_e200-rev-N.dwg2022/07/01 3:29 PM By: Roundtree, OriByRevisionAppd.YY.MM.DDAISSUED FOR CLIENT REVIEWORCL21.05.12BCROSSING UPDATEODRLYZ21.06.08CRELOCATE BRIDE CROSSING ODRLYZ21.06.10DPROVIDED PERIMETER WALLODRWAZ21.06.29EADDED PERIMETER SECURITY FENCEODRWAZ21.07.09FCHANGED BATTERY MFG TO ENERGSYSODRWAZ21.07.22GADDED AUX GEAR, SCE AREA, POWIN MFGODRWAZ21.09.13HADDED 15' SETBACK FROM EASEMENTS, LIGHTINGODRWAZ21.11.17IADDED SCREEN WALL ODRLYZ21.11.22ODRLYZ22.01.21JUPDATED PER CLIENT REQ.ByIssuedAppd.YY.MM.DDMADDED LANDSCAPING AREAS TO LEGENDODRLYZ22.05.26NMODIFIED WALL AND ADDED APN NOSODRLYZ22.06.30Chkd.Dwn.Dsgn.YY.MM.DDFile Name:ORTEGA_E200-REV-N.DWGVADODRLYZ21.07.09NORTEGA GRID LLCORTEGA GRID BATTERY ENERGY STORAGE SYSTEMPROPOSED BESS AND INTERCONNECTLake Elsinore, CA, USAGENERAL ARRANGEMENTELECTRICAL1858051331"=30'E20011NPROJECT MV SWITCHGEARSCE SWITCH POLESCE TAP POLE9' BETWEEN BESSCONTAINERS (TYP)SCE PAD-MOUNTEDSF6 SWITCHGEARSCE RECLOSER POLESCE METER RISERPOLE24' ACCESS ROADAUXILIARY EQUIPMENTAREAKUPDATED FENCE ON NORTH PLVADLYZ22.03.07LEDITED FRONTAGE LIMITS OF SCREEN WALLVADODR22.03.09ORTEGA BESS SITE Drawing No. Scale Revision Title Project No. Sheet of ORIGINAL SHEET - ANSI D www.stantec.com 200 East Carrillo Street, Suite 101 Santa Barbara, CA 93101 Consultants Client/Project The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay. The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.\\us0377-ppfss01\workgroup\1858\active\185805133\03_data\CAD\Ortega_e201-revE.dwg2022/03/09 12:53 PM By: Delgado, VinceByRevision Appd.YY.MM.DD A ISSUED FOR CLIENT REVIEW ODR WAZ 21.06.29 B ADDED PERIMETER SECURITY FENCE ODR WAZ 21.07.09 C SWTICH TO ENERGPORT BATTERY STORAGE ODR WAZ 21.11.22 D ADJUSTED DIMENSIONS ODR LYZ 22.01.21 E RAISED WALL HEIGHT, ADJ. GSU DIMENSIONSODR LYZ 22.03.08 ByIssued Appd.YY.MM.DD Chkd.Dwn.Dsgn.YY.MM.DD File Name:ORTEGA_E201-REVE.DWG VAD ODR LYZ 21.07.09 ORTEGA GRID LLC ORTEGA GRID BATTERY ENERGY STORAGE SYSTEM PROPOSED BESS AND INTERCONNECT California, USA BATTERY LINEUP ELEVATION A-A 185805133 N.T.S. E201 1 1 E Drawing No. Scale Revision Title Project No. Sheet of ORIGINAL SHEET - ANSI D www.stantec.com 200 East Carrillo Street, Suite 101 Santa Barbara, CA 93101 Consultants Client/Project The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay. The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.\\us0377-ppfss01\workgroup\1858\active\185805133\03_data\CAD\Ortega_e202-revD.dwg2022/03/09 12:49 PM By: Delgado, VinceByRevision Appd.YY.MM.DD A ISSUED FOR CLIENT REVIEW ODR WAZ 21.06.29 B ADDED PERIMETER SECURITY FENCE ODR WAZ 21.07.09 C SWTICH TO ENERGPORT BATTERY STORAGE ODR WAZ 21.11.22 D UPDATED DIMENSIONS ODR LYZ 22.01.21 ByIssued Appd.YY.MM.DD Chkd.Dwn.Dsgn.YY.MM.DD File Name:ORTEGA_E202-REVD.DWG VAD ODR LYZ 21.07.09 ORTEGA GRID LLC ORTEGA GRID BATTERY ENERGY STORAGE SYSTEM PROPOSED BESS AND INTERCONNECT California, USA SWITCH GEAR ELEVATION "B-B" 185805133 N.T.S. E202 1 1 D CAMINO DEL NORTECLPARCEL A PARCEL B PARCEL C INTERSTATE 15 GRAPHIC SCALE 38 TECHNOLOGY DRIVE, SUITE 100 IRVINE, CA 92618 949.923.6000 stantec.com SHEET OF 1 JOB NO. 185805036PRELIMINARY GRADING AND DRAINAGE PLAN BATTERY ENERGY STORAGE SYSTEM (BESS) FOR ORTEGA GRID, LLC. 1 EARTHWORK QUANTITIES ESTIMATE: EARTHWORK RAW CUT: RAW FILL: TOTAL IMPORT: QUANTITIES 6 CY 30 CY 24 CY LEGEND: PROPERTY LINE JOIN/DAYLIGHT LINE PROPOSED CONTOUR LINE EXISTING CONTOUR LINE SITE ACCESS ROAD EASEMENTS: N VICINITY MAP EASEMENT PREFABRICATED BRIDGE/ NEW CONCRETE PAVEMENT NEW LANDSCAPE AREA NEW CMU WALL NEW FENCE NEW GRAVEL SURFACE A -SECTION A-A A - NEW AC PAVEMENT Approximate material quantities associate with the potential future widening of Camino Del Norte along the project frontage : CAMINO DEL NORTECLCLCAMINO DEL NORTE PARCEL B PARCEL C INTERSTATE 15CAMINO DEL NORTECLPARCEL A PARCEL B PARCEL C INTERSTATE 15VACANT LOT -RESIDENTIAL ZONECAMINO DEL NORTE RV TRAILER SALES - COMMERCIAL ZONE N.I.C. N.I.C. NET LOT: 77,972 SF (1.79 ACRES) LANDSCAPE AREA: 8,825 SF PLANT SCHEDULE PARKING LOT: 0 SF PARKING LOT TREES: 0 TURF: 0% REFERENCE NOTES SCHEDULE Drawing No. Scale Revision Title Project No. Sheet of ORIGINAL SHEET - ANSI D www.stantec.com 200 East Carrillo Street, Suite 101 Santa Barbara, CA 93101 Consultants Client/Project The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay. The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.\\us0352-ppfss01\workgroup\1858\active\185804133\landscape\design\drawing\185805133 L1 L2 L3 Prelim LFX.dwg2022/06/24 2:40 PM By: Maddock, GaylynByRevision Appd.YY.MM.DD ByIssued Appd.YY.MM.DD Chkd.Dwn.Dsgn.YY.MM.DD File Name:185805133 L1 L2 L3 PRELIM LFX.DWG GAM DC GAM 22.06.24 ORTEGA GRID, LLC ORTEGA GRID BATTERY ENERGY STORAGE SYSTEM PROPOSED BESS AND INTERCONNECT Lake Elsinore, CA, USA CONCEPTUAL LANDSCAPE PLAN 185805133 1"=30' L1 1 3 - SITE / POWER LEGEND CITY REQUIREMENTS - C2 GENERAL COMMERCIAL ALL NEW TREES ARE IN THE 'MODERATE WATER USE HYDROZONE' AND NEW SHRUBS & GROUNDCOVERS ARE IN THE 'LOW WATER USE' HYDROZONE PLANT REQUIREMENTS: TREES - 20% 36" BOX, 50% 24" BOX TREES, SHRUBS - 5 GALLON, SPACED 3' OC MAX. WOODY GROUNDCOVER - 3' OC MAX. SMALL ACCENT PLANTS - 1 GALLON N BUFFERS: 20' AVERAGE (15' MIN) LANDSCAPE BUFFER ADJACENT TO PUBLIC ROW. 10' AVERAGE (5' MIN) LANDSCAPE BUFFER TO ADJACENT PROPERTIES SLOPES : GREATER THAN 3' HT AND 3:1 SLOPE TO BE PERMANENTLY PLANTED AND IRRIGATED TO PREVENT EROSION. CUT/FILLED SLOPES GREATER THAN 3' HT TO BE PERMANENTLY PLANTED AND IRRIGATED : 40% COVERAGE OR 25 SHRUBS/1000 SF. (2) TREES /1000 SF NOTE: THIS PLAN HAS ESTABLISHED SLOPES THAT ARE TO REMAIN. ONLY NEWLY GRADED OR DISTURBED SLOPES WILL BE PLANTED PER THE ABOVE REQUIREMENT. STREET TREES: (1) 24" BOX TREE / 30 LF OF FRONTAGE. 309 LF = 10 TREES REQUIRED. 10 PROVIDED TREES SELECTED FROM CITY LIST 6' WIDE LANDSCAPE ON EXTERIOR OF PERIMETER WALLS AND FENCES W/ TREES, SHRUBS, AND GROUNDCOVERS Drawing No. Scale Revision Title Project No. Sheet of ORIGINAL SHEET - ANSI D Consultants Client/Project The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay. The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.\\us0352-ppfss01\workgroup\1858\active\185804133\landscape\design\drawing\185805133 L1 L2 L3 Prelim LFX.dwg2022/06/24 2:33 PM By: Maddock, GaylynByRevision Appd.YY.MM.DD ByIssued Appd.YY.MM.DD Chkd.Dwn.Dsgn.YY.MM.DD File Name:185805133 L1 L2 L3 PRELIM LFX.DWG GAM DC GAM 22.06.24 ORTEGA GRID, LLC ORTEGA GRID BATTERY ENERGY STORAGE SYSTEM PROPOSED BESS AND INTERCONNECT Lake Elsinore, CA, USA CONCEPTUAL LANDSCAPE PLAN 185805133 1"=30' L2 2 3 - LEUCOPHYLLUMCEANOTHUS ARCTOSTYAPHYLOS FRANGULA WATER CONSERVATION CONCEPT A COMBINATION OF SUB-SURFACE LOW FLOW DRIP, BUBBLERS, AND/OR LOW VOLUME HUNTER MP ROTATOR SPRAYS SHALL BE INSTALLED IN ALL PLANTERS. PLANTS ARE GROUPED INTO "HYDROZONES" AND IRRIGATED SEPARATELY FROM THOSE WITH DIFFERENT WATER REQUIREMENTS. IRRIGATION SYSTEM SHALL BE EQUIPPED WITH A WEATHER TRACK CONTROLLER CAPABLE OF DUAL PROGRAMMING. FLOW SENSOR LEAK DETECTION AND AUTOMATIC SHUT-OFF TO BE PROVIDED AT POC. ALL SURFACE AND SUB-SURFACE SWALES, DRAINAGE STRUCTURES AND PATTERNS SHALL BE MAINTAINED. A LICENSED LANDSCAPE MAINTENANCE CONTRACTOR WILL BE RETAINED TO PERFORM ROUTINE MAINTENANCE DUTIES. LOCATIONS AND QUANTITIES OF EXISTING LANDSCAPE MATERIALS ARE APPROXIMATE. PLANTER SOIL SHALL BE AMENDED AS DESCRIBED BY A LABORATORY SOIL ANALYSIS. ORGANIC COMPOST AND AMENDMENT TO BE USED. FIRE HYDRANTS UTILITY BOXES, MANHOLE AND OTHER UTILITY VAULTS, TELEPHONE AND OTHER UTILITY POLES, GAS AND WATER METER, AND MAINS REFER TO ELECTRICAL AND CIVIL PLANS FOR DESCRIPTIONS OF ELEMENTS NOT IDENTIFIED ON THIS PLAN. OBSERVE THE FOLLOWING MINIMUM SETBACK DISTANCES FOR TREE PLANTING : ALL NEWLY PLANTED AREAS SHALL HAVE A 2" LAYER OF ORGANIC COMPOST ROTOTILLED TO A DEPTH OF 4" AND TOPDRESSED WITH 3/4" MINUS CRUSHED ROCK OR DECOMPOSED GRANITE WITH ORGANIC STABILIZER, TO A MIN. DEPTH OF 3". COLOR: TAN. = 15 FT. = 15 FT. = 5 FT. BETWEEN STREET TREES 1. 2. 3. 4. 5. 6. 7. 8. GENERAL NOTES LANDSCAPE CONSTRUCTION WASTE TO BE RECYCLED PER LOCAL CODES AND REQUIREMENTS. NO PLANTS SELECTED REQUIRE SHEARING9. OBTAIN ALL MATERIALS LOCALLY (WITHIN 50 MILES) AS POSSIBLE.10. CONTRACTOR TO ARRANGE FOR CERTIFICATION AND AUDIT PER CITY REQUIREMENTS. 11. EROSION CONTROL MATTING TO BE USED ON ALL SLOPES 3:1 AND GREATER.12. DRIVEWAY CUTS = 10 FT. EXISTING SITE - VIEW FROM CAMINO DEL NORTE SALVIAPODOCARPUS PINUS MYOPORUM www.stantec.com 200 East Carrillo Street, Suite 101 Santa Barbara, CA 93101 Drawing No. Scale Revision Title Project No. Sheet of ORIGINAL SHEET - ANSI D Client/Project The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay. The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.\\us0352-ppfss01\workgroup\1858\active\185804133\landscape\design\drawing\185805133 L1 L2 L3 Prelim LFX.dwg2022/06/24 2:33 PM By: Maddock, GaylynByRevision Appd.YY.MM.DD ByIssued Appd.YY.MM.DD Chkd.Dwn.Dsgn.YY.MM.DD File Name:185805133 L1 L2 L3 PRELIM LFX.DWG GAM DC GAM 22.06.24 ORTEGA GRID, LLC ORTEGA GRID BATTERY ENERGY STORAGE SYSTEM PROPOSED BESS AND INTERCONNECT Lake Elsinore, CA, USA COLORS AND MATERIALS 185805133 NONE L3 3 3 - TRANSFORMER ON PAD PROJECT MV SWITCHGEAR MATERIAL: METAL COLOR: WHITEMATERIAL: METAL COLOR: WHITE MATERIAL: METAL COLOR: WHITE MATERIAL: METAL COLOR: WHITE WALL WITH PILASTER MATERIAL: SPLITFACE CMU COLOR: TAN & GREY SECURITY FENCE BATTERY UNIT PAD-MOUNT GSU MATERIAL: METAL COLOR: WHITE CONTAINER-MOUNTED LIGHT MATERIAL: METAL COLOR: WHITE WALL-MOUNTED LIGHT www.stantec.com 200 East Carrillo Street, Suite 101 Santa Barbara, CA 93101