Loading...
HomeMy WebLinkAbout0006 CONSTRUCTION NOTES (THIS SHEET) CONDUCTOR SCHEDULE ❑1 - FURNISH AND INSTALL MCCAIN MODEL 2070 ATC eX CONTROLLER ASSEMBLY WITH A 332 CABINET AND FOUNDATION. NOTICE TO CONTRACTORS POLE SCHEDULE CONDUIT SIZE & RUN NUMB MODEL 2070 ATC eX CONTROLLER UNIT SHALL INCLUDE OOnl eX SOFTWARE READY TO INTEGRATE WITH CITY'S PURSUANT TO ASSEMBLY BILL 3019, NO EXCAVATION PERMIT STANDARD LUMINAIRE SIGNAL MOUNTING PPB POLE LOC.•• AWG SIZE POLE TRANSPARITY TRAFFIC MANAGEMENT SOFTWARE, AND BI TRAN 2033 PROGRAM. FURNISH AND INSTALL ITERIS .... IISNS (LED) LEGEND REMARKS 3" 3" 3.5" T 3".2-3" VANTAGE EDGE 2 VIDEO DETECTION SYSTEM COMPLETE WITH PROCESSORS, EXTENSION MODULES, VRACK, MONITOR IS VALID UNLESS.THE FOLLOWING IS PERFORMED. No. TYPE g HGT. SIG. M.A LUM. M.A. LED VEHICLE PED PHASE QUAD A, B OR OR AND MOUSE. FURNISH AND INSTALL TRAFFIC TECHNOLOGIES (GTT) EMERGENCY PRE-EMPTION SYSTEM WITH MODEL CABLE TYPE CIRCUIT Q Q Q Q Q Q 764 MULTIMODE PHASE SELECTOR. FURNISH AND INSTALL FIBER DISTRIBUTION UNIT CORNING C-MIC-012 COMPLETE 1. UNDERGROUND SERVICE ALERT HAS BEEN CONTACTED AND A 29-5-100 30' 55' 15' 25OW Tassel Wy 3MAS SV-1-T SP-1-T 8 E 15, 4' F 19' 1 2 3 4 5 6 AND TERMINATE THE 12 SMFO CABLE FIBERS, CIS CO ETHERNET SWITCH MODEL IE-3000-8TC WITH TWO FIBER HAS PROVIDED INQUIRY I.D.• © 1-A 10, TV-I-T SP-1-T 6 S 13' 3' POLE - A - 11 1 TRANCEIVER PORTS AND WITH POWER SUPPLY. INTEGRATE SWITCH AND FIBER EQUIPMENT FOR INTENDED OPERATION. 2. THE UNDERSIGNED AGREES TO CONTACT AND OBTAIN AN C TYPE 15TS 30' 15, 25OW - 6 S 17' 3' - FURNISH AND INSTALL EXTERNAL BATTERY BACK-UP SYSTEM (BBS) DIMENSIONS MODEL •24M11-WBE AND MOUNT ON INQUIRY I.D.• FROM UNDERGROUND SERVICE ALERT 12CSC 6 - - - - - 1 THE SIDE OF THE CONTROLLER CABINET PER THE COUNTY OF RIVERSIDE TRANSPORTATION DEPARTMENT TRAFFIC - D 1-A 10, - - - - - TV-2-T SP-1-T - - 18' 3' - C -_ 1 1 11 OPERATIONS REQUIREMENTS. FURNISH AND INSTALL ALL THE APPURTENANCES AND NECESSARY EQUIPMENT FOR (1-800-227-2600) AT LEAST 2 WORKING DAYS PRIOR D _ _ 1 1 1 INTENDED OPERATION. SEE CITY SPECIFICATIONS. TO COMMENCEMENT OF EXCAVATION. E 29-5-100 30' 50, 15, 25OW Tassel Wy 3MAS SV-2-TB STA 86-38 3' F-16' E 1 1 _ _ 2❑- FURNISH AND INSTALL 120/240 VOLT, DUAL METER TYPE III-CF SERVICE EQUIPMENT ENCLOSURE ANODIZED SIGNED _ _ DATE _ F 17-3-100 30' 20' 12'(a) 250W Railroad Canyon Rd MAS-4B SV-3-TB SP-1-T 8 W STA 85+64 4' - 3CSC - - WITH TYPE V PEC PER CALTRANS STANDARD PLAN ES-2F AND COUNTY OF RIVERSIDE REQUIREMENTS, AND F -_ 1.1 1.1 THE FOLLOWING CIRCUIT BREAKERS- SERVICE POINT PER • ALL IISNS ARE SHAFT MOUNTED. IISNS ARE EDGELIT LED OR APPROVED EQUAL. SCE JOB NO. 0644600 ■• POLE LOCATION TO BE DETERMINED IN THE FIELD BY THE RESIDENT ENGINEER. DETECTOR SCHEDULE TOTAL 1_ 1 3 2 _ 1 4 (1) 120/30A, 00A, MAIN. (SCE SHEET 2 OF 3) •■• ALL POLE TYPES ARE REFERED TO CALTRANS STANDARD DATED MAY 2010. •6 GROUND 1 1 1 1 1 1 (1) 120/30A, METERED SIGNAL. •«• LED LUMINAIRES EQUIVALENT TO 250W PER CITY APPROVAL. NO. PHASE SLOT TERMINAL (1) 120/15A, METERED LIGHTING. - R (a) ROTATE LUMINAIRE 90 DEGREES LEFT, - AWG •10 LUMINAIRE 2 2 2 - 2 - (1) 120/15A, � METERED IISNS. 1 2 12U T2-5&6 •12 IISNS 2 2 2 - - - M- INSTALL 3" SCHEDULE 80 PVC CONDUIT WITH PULL ROPE PER SOUTHERN CALIFORNIA ,rF PHASE DIAGRAM 2 2 12L T2-7&8 EDISON (SCE) REQUIREMENTS, AT LEAST 48 HOURS ADVANCE NOTICE SHALL BE GIVEN TO I R 3 2 13U T2-9&10 BELDEN COAX VIDEO CABLE 1 2 3 - - 3 Q SCE PROJECT MANAGER JERRY CHAMBERLAIN (9511 249-8498 PRIOR TO INSTALLATION.3*16 CAMERA POWER CABLE 1 2 3 - - 3 _ 4 5 J1U T3-1&2 4�- FURNISH AND INSTALL GTT OPTICOM DETECTOR MODEL 721 ON SIGNAL MAST ARM. r � NDT NDT 5 8 J6U TS-9&10 OPTICOM CABLE (MODEL 138 1 2 3 - - 3 FURNISH AND INSTALL OPTICOM CABLE MODEL 138 THROUGH CONDUIT TO CONTROLLER V YAASSEMBLY FOR INTENDED OPERATION. CONTACT GTT COMPANY REPRESENTATIVE FOR ! USED USED 6 8 46L T5-11&12 ERCENTCONDUIT FILL (X) 11 21 23 6 9 21 DETECTOR OPTIMUM LOCATION AND TECHNICAL SUPPORT. 7 6 J2U T3-5&6ALL CONDUITS AND CONDUCTORS ARE NEW. 5 - FURNISH AND INSTALL ITERIS RZ-4 ADVANCED WDR VIDEO DETECTION CAMERA ON CIA CIA 01 02 03 04 8 6 J2L T3-7&8 LUMINAIRE MAST ARM PER MANUFACTURER'S SPECIFICATIONS.. ' 6 J3U T3-9&10 6❑- FURNISH AND INSTALL •6 PULL BOXES FOR FIBER OPTIC CABLE FROM TASSEL WAY GREEN ARROW AND DETAIL nB Y A NEVD 1 11U T2-1&2 TO WESTRIDGE WAY AT MAXIMUM 500' SPACED AND AS INDICATED ON PLANS. GREEN BALL SHALL a 7 o—-—0 NOT T 6 113U T8-7&COM9 No SCALE 3I 27, SIGNAL STANDARD APPROXIMATELY 2,400' DISTANCE BETWEEN.THE TWO CONTROLLER CABINETS. BE SIMULTANEOUS_ W USED 1I 8 113L T8-8&COM9 PROVIDE 20' OF 72 SMFO CABLE SLACK IN PULL BOX. DETAIL "A r° 14 11©' �, 24 7 ¢ PLACEMENT DETAIL �— V 2&5 J12U T9-4&COM6 TRAFFIC SIGNS (THIS SHEET) �7 - FURNISH AND INSTALL 3" CONDUIT WITH PULL ROPE. FURNISH AND INSTALL 72 NO SCALE 3 w� NO SCALE �5 fl16 (67 ¢8 1&6 J12L T9-5&COM6 SINGLE MODE FIBER OPTIC (SMFO) CABLE WITH •8 AWG GREEN INSULATED 9 - 6 8 J13L T9-8&COM9 STRANDED COPPER TRACE WIRE. FLASHING OPERATION SHALL BE ALL RED. �8 - FURNISH AND INSTALL 3" CONDUIT WITH PULL ROPE. FURNISH AND INSTALL 12 ��c 5 - I14U T8-10&COM12 BesTwnr SMFO DROP CABLE WITH •8 AWG GREEN INSULATED COPPER TRACE WIRE FROM 2 B O 08 td - - O 4 NEW COMMUNICATIONS VAULT TO CONTROLLER CABINET. ` NO UTURN Iii] 2"C,4*10(LUM),4*12(IISNS),is6(BARE) _�" R9-3 R9-3a R73-2(CA) R73-3(CA) SP-U 0- FURNISH AND INSTALL A COMMUNICATIONS VAULT WITH MINIMUM DIMENSIONS 7 3"C,72 SMFO CABLE OF 30"WX6O%x36"D NEAR THE CONTROLLER CABINET. INSTALL FIBER CLOSURE 2"C,2.6(SIGNAL) \, E TRIDGE WAY CORNING SCF-6C22-01-72 COMPLETE IN COMMUNICATION VAULT. FUSION SPLICE RW THE NECESSARY FIBERS OF THE 72 SMFO AND ALL THE 12 SMFO CABLE FIBERS IN RAILROAD 1 OA 6 SPLICE ENCLOSURE. TAG LABEL ALL THE FIBER CABLES. PROVIDE 200' OF 72 SMFO 06P SIDE LK AND 12 SMFO CABLES SLACK IN COMMUNICATION VAULT. RW CANYON 3 -- — ___ ! ,. -3& 3ap IS ..... . 9 ..... - .__. V 1 S ..,> m allr ;- 345' TO SP-U IS 06 'm LIMIT LINE — — _._.- .....__ _ • i _A F� .G FC 01 5J1U v m LL N 4 345' TO ACK — - N 5 TAIL A 02 V ',.� _ tii 7• OE " E A m OF CROSSWALK a e a V' 4 v — 08 i 02 ! 5 V 08 15 R9-3&9-3a m 1 DETAIL '8" SP a: 21 ----- —' SIDEWALK SIDEWALK RW ( F, EVD -- O -- -.- RW TRAFFIC SIGNAL GENERAL NOTES �J 4 1S R773-3(CA) 1 N LEGEND, N 1. ALL WORK, MATERIAL, AND EQUIPMENT SHALL CONFORM TO THE REQUIREMENTS OF THE 5. ALL RED, YELLOW, AND GREEN SIGNAL INDICATIONS, AND PED INDICATIONS SHALL BE LIGHT EMITTING 12.ALL TRAFFIC SIGNAL DETECTION, SIGNING, PAVEMENT MARKINGS AND STRIPING FOR ALL DIRECTIONS SHALL BE COMPLETED �r-SIGN TYPE. _ CALIFORNIA DEPT. OF TRANSPORTATION, STANDARD PLANS AND STANDARD SPECIFICATIONS DIODE (LED), SIGNAL LENSES SHALL BE 12" WITH METAL HOUSING, VISORS AND BACKPLATES. PRIOR TO TRAFFIC SIGNAL ACTIVATION. X W E DATED 2010, THE CALIFORNIA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (CA MUTCO - IS INSTALL SIGN AS INDICATED. o 2014), THE COUNTY OF OF RIVERSIDE TRANSPORTATION DEPARTMENT REQUIREMENTS, AND 6. THE LOCATION OF SIGNAL POLES, CABINETS, AND OTHER EQUIPMENT SHOWN ON THE PLAN IS APPROXIMATE. 13.CONDUCTOR SCHEDULE IS FURNISHED AS AN INSTALLATION GUIDELINE ONLY. IT SHALL BE THE CONTRACTOR'S XX THE SPECIAL PROVISIONS FOR THIS PROJECT. THE EXACT LOCATION SHALL BE DETERMINED IN THE FIELD BY THE ENGINEER, RESPONSIBILITY TO PROVIDE THE CORRECT CONDUCTORS REQUIRED FOR THE INTENDED OPERATION. L MA=MOUNT ON MAST ARM. TP=MOUNT ON TELESPAR POST. 2. UTILITIES SHOWN ON THESE PLANS ARE CORRECT AND ACCURATE TO THE EXTENT OF 7. STREET NAME SIGNS SHALL BE DIAMOND GRADE VIP REFLECTIVE SHEETING, WHITE LETTERS ON BLUE 14,ALL WIRING AND EQUIPMENT SHALL BE MARKED (TAGGED) WITHIN THE CONTROLLER CABINET FOR PHASE IDENTIFICATION. S SP=MOUNT ON SIGNAL POLE. 1D AVAILABLE RECORDS AND KNOWLEDGE. THE CONTRACTOR, HOWEVER, IS REQUIRED TO BACKGROUND WITH CITY LOGO AND "CITY OF LAKE ELSINORE" BELOW STREET NAME. QUADRANT WP=MOUNT ON WOODEN POST. u ASCERTAIN THE EXACT LOCATION OF UNDERGROUND FACILITIES PRIOR TO DOING WORK THAT 8 PEDESTRIAN SIGNAL FACES SHALL BE TYPE "A" PEDESTRIAN HEAD WITH LED UNIFORM INCANDESCENT 15.UNDERGROUND SIGNAL LIGHT CONDUCTORS SHALL NOT BE SPLICED. PPB LOCATION o MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICE. THE CONTRACTOR SHALL LOOK COUNTDOWN MODULE PER CA MUTCD. NO SCALE BEAR THE TOTAL EXPENSE OF REPAIR OR REPLACEMENT OF ANY UNDERGROUND FACILITIES 16.SEE CALTRANS STD. PLAN ES-1A AND ES-1B FOR SYMBOL AND ABBREVIATION LEGEND. o DAMAGED BY HIS OPERATION. PHONE UNDERGROUND SERVICE ALERT 811 MINIMUM 48 HOURS g,pEDESTRIAN PUSH BUTTONS SHALL BE TYPE "B" ADA BUTTONS WITH INTERNATIONAL SYMBOL SIGN PLATE IN ADVANCE. - PER CALTRANS SIGN SPECIFICATIONS R10-3. 17.ALL DETECTION SHALL BE VIDEO DETECTION. DETECTION ZONES FOR VIDEO DETECTION SYSTEM ARE SHOWN AS A GUIDELINE 20 10 0 20 40 60 ONLY AND ARE NOT A PHYSICAL INSTALLATION. c 1 3. THE CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS AND NOTIFY ALL UTILITY iO.ALL NEW CONDUIT SHALL BE 3" PVC UNLESS SHOWN OTHERWISE. - GRAPHIC SCALE 1"- 20' COMPANIES AND UNDERGROUND SERVICE ALERT A MINIMUM OF 48 HOURS PRIOR TO START OF - 18.ALL SALVAGED EQUIPMENT NOT REUSED SHALL BE DELIVERED TO THE CITY OF LAKE ELSINORE CITY YARD UNLESS OTHERWISE CONSTRUCTION. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE.ALL 11.CONTRACTOR SHALL PLACE CONDUIT BY JACKING OR DRILLING UNLESS APPROVED BY CITY ENGINEER DIRECTED BY THE ENGINEER IN THE FIELD. a PHASES OF CONSTRUCTION WITH THE VARIOUS UTILITY COMPANIES INVOLVED INCLUDING SCE. OR HIS REPRESENTATIVE. W 19.IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO HAVE A VIDEO DETECTION AND EVP MANUFACTURER'S REPRESENTATIVES o 4. ALL TRAFFIC SIGNAL EQUIPMENT SHALL BE FURNISHED AND INSTALLED BY THE CONTRACTOR AT THE SITE DURING TRAFFIC SIGNAL TURN-ON ACTIVATION. UNLESS OTHERWISE SPECIFIED. NOTE: THIS PLAN ACCURATE FOR ELECTRICAL WORK ONLY. CONTRACTOR'S LICENSE REQUIRED FOR THIS PROJECTv CLASS A OR C-10 _ BENCH MARK: DIG ALERT REVISIONS APPRV DATE SEAL: 250UTH POINTEDRIVE-SUITE 275 d—'I<905C CAUTION; OF EXISTING UTILITIES ON THESE PLANS SHEET THESE PLANS HAVE BEEN REVIEWED FOR COMPLIANCE WITH LAKEFORE6T,CA 9263D ARE APPROXIMATE AND SHALL BE VERIFIED BY CONTRACTOR CITY O F LAKE ELSINORE ELEVATION: 1400.873(NGVD 29) THE APPROPRIATE CONDITIONS OF DEVELOPMENT AND/OR �"4( 949.SBB.0707 PRIOR TO CONSTRUCTION. TRAFFIC SIGNAL PLAN (3 RIVERSIDE COUNTY DESIGNATION:E-14-70 e x CITY AND STATE LAWS,AND A PERMIT CAN BE ISSUED. , (FAX)949.588.0709 OF DESCRIPTION:2.7 MILES NORTHEAST ALONG o UNAUTHORIZED .CHANGES FOR CANYON HILLS PH. 8+N N y ENGINEERING COMPANY ri,kengineerin. 11 m 2:_ RAILROAD CANYON ROAD FROM THE CALL BARRY J.COWAN ,,. CAUTION:THE ENGINEER PREPARING THESE PLANS WILL NOT-BE INTERSECTION OF RAILROAD CANYON ROAD BEFORE 46568 s 'orange San Diego Bb ide-SanL"sObispo-BA—field Sa<mmeMo-Phcennc-Tucson VTTM #136117 & #'36118 AND STATE HIGHWAY 71,122.0 FEET N, YOU DIG! i No. PREPARED UNDER THE DIRECTION OF: RESPONSIBLE OR LIABLE FOR UNAUTHORIZED CHANGES TO THESE S NORTHWEST OF RAILROAD CANYON ROAD, .. /-�f- 6 » PLANS. ALL CHANGES TO THESE PLANS MUST BE APPROVED SHEETS BY THE PREPARER OF THESE PLANS AND THE CITY ENGINEER. 6.0 FEET SOUTHWEST OF POWER POLE , FILE NO. 0 o KEN J.RUKAVINA,RCE•42866 DATE-1853T3 Jf CIVIL �! RAILROAD CANYON ROADS TASSEL WAY o= MARKER 2POST'A BRASS DISK 1.0 FEET ASET INST OF THE 1-800-227-2600 CHECKED �W� df a SCALE: SHEET SPECIFIC - MTERIM CITY ENGINEER r T � DATE TO o 6 o TOP OF CONRETE POST E-14-70. COP at l UNDERGROUND d SERVICE ALERT DESIGNED BY: DRAWN BY: BY. CITY OF LAKE ELSINORE OF CA\Y BARR AN,RCE C46568 DATE DATE: - a