HomeMy WebLinkAbout16401 LAKESHORE DR_ 02-1330 (2)16401 LAKESHORE DR 02 -1330 2 OF 6
ANTENNA ASSEMBLY
P/N : 104591 -001
OR
P /N: 104591 -003 -`
m
UNISTRUT P1538A
FITTING DRILLED TO
MATCH "GPS" HOLES
UNISTRUT P1000
N' FEMALE CONNECTOR
20' 11/2" OON CABLE
NOTE:
2
TRAY
ANTENNA AND ANTENNA MOUNTING BRACKET PCS CDMA MINICELL
CPS ANTENNA INSTALLATION GUIDELINE. GENERAL CONTRACTOR
TO VERIFY W/ SPR :NT FOR GPS ANTENNA KIT a REQUIREMENTS
GPS ANTANNA DETAIL 1 NOT USED sue: 4NONENONE
ANTENNA
AZIMUTH
ANTENNA COAXIAL CABLE CABLE CONDUIT
SECTOR MANE /MODEL LENGTH SIZE SIZE
SECTOR
100•
COMSAT
4 z 100' 7 /8" ON CABLEALPHAPCSSO65 -13 -2 TRAY
SECTOR 200•
COMSAT
4 z 100' 7/8" ONTO LEBETAPCSSO85 -'3 -2
SECTOR 290. COMSAT
4 z 100' 7/8" ONE LEGAMMAPCSSO65 -13 -2
GPS N/A
LUCENT
COAX CABLE SCHEDULE 2 NOT USED 5
N
NOT USED 3 NOT USED gN
t
Spri nt PCS "
4883 CHASOT DRIVE, SUITF. 100
PLEASANTON, CA 94588
PROJECT INFORMATION:
HIDDEN PINE
RV54XC517D
18401 LAKESHORE DRIVE
LAKE ELSINORE, CA. 92530
COUNTY OF RIVERSIDE
CURRENT ISSUE DATE:
06/11/02
LISSUED FOR:
CONSTRUCTION
EV.:=DATE:-----1 SSUED FOR: 13Y:=
1 oe /11/02 F ONSTRUCnON, 100%
0 05/10/02 CONSTRUCTION 90x
CLANS PREPARED liY:
oft &a
A AFL Telecommunications
wireless Serva fce
12ro
AL MM
m
Pacific 17. Inc aLw (W a1-om
C5
DETAILS
SHEET NUMBER: REVISION:
300,CA,83
20' 11/2" OON CABLE2
TRAY
SSUED FOR: 13Y:=
1 oe /11/02 F ONSTRUCnON, 100%
0 05/10/02 CONSTRUCTION 90x
CLANS PREPARED liY:
oft &a
A AFL Telecommunications
wireless Servafce
12ro
AL MM
m
Pacific 17. Inc aLw (W a1-om
C5
DETAILS
SHEET NUMBER: REVISION:
300,CA,83C5
DETAILS
SHEET NUMBER: REVISION:
300,CA,83
J
x •
BAR
184X 'X 1/4,e ROUTE GROUND WIRE
ALONG CABLE
I
I
TRAY I
COAX CABLE
ALONG CABLE TRAY
j- —J
II 12' -0'
I
e, - - -- o
OWER
CABINETT
I I CABINET
n I -- -- 1 -- - - -- - - - - --
6•
FLEXANT , I CTTEECABINET
6•
MAIN G49UND QAR 4
02 BCW
24' % 4 X 1 4• SEE DETAIL 1 2
NEW 8' -3' X I V -0 E) GROUND ROD CONCRETE PAD
yy MAIN
SEE DETAIL 2 OROUND RING
BURIED 24' M I N,
BELOW GRADE
Al
5/8.0 X 10"
GROUNDING ROD
TYP.). SEE
DETAIL
44
CADWELD (iYP.)
sEE DEraL 3 s
E3
GROUNDING INSPECTION
TEST WELL (TYP. 2)
J
SEE DETAIL
EQUIPMENT AREA GROUNDING PLAN H
ANTENNAS PER PLAN''
QUANTITY /CONFlCURATION VARIES)
1. THIS IS A DIAGRAMMATIC REPRESENTATION ONLY. SEE GROUNDING
PLAN FOR SITE- SPECIFIC GROUNDING LAYOUT AND COMPONENTS.
2. SEE GROUND NOTES FOR ADDITIONAL. INFORMAnON.
NEW WAVEGUIDE BRIDGE
KIT. 7YP. METAL FENCE POSTS,
1%4'%4'X18' PIPE aOLW fIS
NEW CONCRETE SLAB
WHERE APPLICABLE)
12WQ BFCIM O
RADIO RADIO POYIER BATTERY TELLCCO ELECTRICAL
CT M
lax 0
ANTENNA
2 -HOLE LUG.- CABINET CABINET CABINET CABINET DOIAiE
TYP
OROUND PoNO (12 soup BARE Uf10'-0' O.C. CADwELD, tYP.
TINNED COPPER WIRE)
GROUNDING SYSTEM SCHEMATIC
FPO 6TM
4D TEST
OF 2)
1. ALL DETAILS ARE SHOWN IN GENERAL TERMS. ACTUAL GROUNDING
INSTALLATION REQUIREMENTS AND CONSTRUCTION ACCORDING TO
SITE CONDITIONS.
2. ALL GROUNDING CONDUCTORS: 12 AWG SOLID BARE TINNED COPPER
WIRE UNLESS OTHERWISE NOTED.
3. GROUND BAR LOCATED IN BASE OF EQUIPMENT WILL BE PROVIDED,
FURNISHED AND INSTALLED BY THE VENDOR.
4. ALL BELOW GRADE CONNECTIONS: EXOTHERMIC WELD TYPE. ABOVE
GRADE CONNECTIONS: EXOTHERMIC WELD TYPE.
S. GROU(ID RING SHALL BE LOCATED A MINIMUM OF 24- BELOW GRADE
OR 6 MINIMUM BELOW THE FROST UNE.
6. INSTALL GROUND CONDUCTORS AND GROUND ROD MINIMUM OF
1' -0' FROM EQUIPMENT CONCRETE SLAB. SPREAD FOOTING, OR
FENCE.
7. EXOTHERMIC WELD GROUND CONNECTION TO FENCE POST: TREA"
WITH A COLD GALVANIZED SPRAY.
8. GROUND BARS:
A. EQUIPMENT GROUND BUS BAR (EGB) LOCATED AT BOTTOM OF ANTENNA
POLE /OUST FOR MAKING GROUNDING JUMPER. CONNECTIONS TO COAX
FEEDER CABLES SHALL BE FURNISHED AND INSTALLED BY
ELECTRICAL CONTRACTOR. JUMPERS ( FURNISHED BY OWNERS) SHALL
BE INSTALLED AND CONNECTED BY EL'- CTRICAL CONTRACTOR.
B. MAIN GROUND BUS BAR (MGB) LOCATED NEAR THE BASE OF THE RADIO
EQUIPMENT CABINET(S) SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL
CONTRACTOR.
9. ALL GROUNDING INSTALLATIONS AND CONNECTIONS SHALL BE MADE BY
ELECTRICAL CONTRACTOR.
10. OBSERVE N.E.C. AND LOCAL UTILITY REQUIREMENTS FOR ELECTRICAL
SERVICE GROUNDING.
11, GROUNDING ATTACHMENT TO TOWER SHALL BE AS .LR MANUFACTURER'S
RECOMMENDATIONS OR AT GROUNDING POINTS PROVIDED (2 MINIMUM).
21 GROUNDING NOTES 3
A+ L7
S prin! PCS "
4683 CHABOT DRIVE, SUITE 100
PLFISANTON, CA 94588
HIDDEN PINE
RV54XC517D
16401 LAKESHORE DRIVE
LAKE ELSINORE. CA. 92530
COUNTY OF RIVERSIDE
CURRENT ISSUE DATE:
06/11/02
I CONSTRUCTION I
REV.: = DATE: — ISSUED FOR: BY
1 06/11/02 CONSTRUCTION, 1001 SJV
0 05/10/02 CONSTRUCTION 9OX RL
CLANS PREPARED BY:
AFL Telecommunications
1766 OrOrO- 61AR >WA 7r0
Wireless Services 0 I.Ow AL 35M
Pacific 17, Inc 661» (tad) 001-0717
Fm (766) *1-3417
0 ®00 D*"M M.
71 ANN 6Y omkw awft avima
BRAWN 6Y:— HK.:— ArV.:-
DRAWN BY: SJV SJV RL
1 1/`CAICI IRF•
4
Enh 6/30M
7 `0CTx1L ti!
OF CAt
SHEET TITLE:
GROUNDING PLAN
SHEET NUMBER: REVISION:—
E 2 1
3001CAM
HARDER VOPS STEEL --
WELL COVER
24.000t_ 000 I_ 1.600 ---{
FINISHED GRADE
2.000 p
Q{
p 1.000
1`1
ON / 4 +
j - GREU ACCESS
HER OCCURS
HARDER PS GROUND 4 { 0 T * * * -0 -0 0
ACCESS W 4 *
WHERE OCCURS
0.5620 (e) ®
TINNED BAR
0.4370 (52)
CADWELD TYPE
1O
GROUND RING PER PLAN or MOLD
NO. R415W INSULATOR
CADWELD TYPE WBKT1 BRACKET
GY' MOLD r2 0=1, WELD CONNECTKNI
GROUND ROD PER PLAN
MANUFACTURER: WARDER 15' -0' TAIL (2 PLACES)
GROUND RING /2T TINNED SOLID
PER PIAN
GROUND ROO
PER PLAN
GROUNDING WELL 1 GROUND BAR ASSEMBLY (24 ") NONE 4
CONDUIT TO FIGS CONDUIT
TRAY CLAMP AS REQUIRED
1.000 1.500 18.000
2 AWC tTCw
EE NOTE 1 2.000 E1.000
CABLE TRAY
GROUNDING CLAMP
GROUND WIRE CONNECTOR 0 -Z GEDNEY TYPE. CTGC \
BURNDY TYPE KSU SEE NOTE 2 1
PLAN
GROUNDING CLAMP CONDUIT TO TRAY -
0 -Z GEDNEY TYPE
Ir
CLAMP O -Z GEDNEY
CTGC / TYPE CTC NO. R415OA4 INSULATOR 0.4380 (2) p OM20 (0) 0.422 (10) E)
TINNED BARI 'm
CABLE TRAY
WBKT1 BRACKET
c
INSULATED GROUNDING
FIGS CONDUIT
TYPE BUSHING, BOTH ENDS AS REQUIRED
THREADED, 0 -Z GEDNEY
TYPE HBLG
pf0 EttMl¢ WELD CONNECTION
SECTION (
2 6i
P/rL TCB 4 41BRFFiP
15' -0' TAIL (2 PLACES)
NOTES; 1. GROUND WIRE CONNECTED TO RING GROUND. /
2T TINNED SOLID
2. TYPICAL FOR EACH SECTION OF TRAY.
CABLE TRAY GROUNDING 2 GROUND BAR ASSEMBLY (18 ") 5
NO. 2 SOLID SOFT -
DRAWN BARE COPPER
CONDUCTOR
GTC -161T CADWELD CONNECTION
WITH C150 WELD METAL
NO. 5810, 5/8' X 10'
COPPER CLAD GROUND ROD
20 BUS BAR
81 HARDER
SSC7T CADWELD MOLD
WITH C32 WELD LicTAL
WIRE
25' PIGTAIL PEER PUN
PROVIDED WITH NO. 2 SOLID SOFT -
BUS BAR DRAWN BARE COPPER
CONDUCTOR -
CADWELD TYPE
W TYPE
NC' MOLD PCCITIT CADWELD MOLD
GROUND WIRE
GROUND WIRE WITH C45 WELD METAL
PER PLAN
PER PLAN
N0. 2 SOLID SOFT-
GROUND ROD
GROUND ROD DRAWN BARE COPPER
PER PLAN
PER PLAN CONDUCTOR
MASTER GROUND BAR & CADWELD CONNECTIONS NM
3 CADWELD DETAILS Mw
6
A*Sprint.
Sprint TICS "
4683 CHABOT DRIVE, SUITE 100
PLEASANTON, CA 94588
HIDDEN PINE
RV54XC517D
16401 LAKESHORE DRIVE
LAKE ELSINORE, CA. 92530
COUNTY OF RIVERSIDE
06/11/02
CONSTRUCTION
FOR:
1 06/11/02 CONSTRUCTION, 1OD%
0 05/10/02 CONSTRUCTION 90x RL
PREPARED
JLAFL Telecommunications
Wireless Services 1700 AL 3K42
Pwt k 17, Inc oft* (2" N1-+7
Fa M M1 -3117
BONN Enlilme s, Inc.
NOW" d amw 1110w
hRied am6w
2101.0"
luMlMM r WE
DRAWN BY: SJV I SJV I RL
PApfESS ry,
4
f
En. 6/36/61 •
or CAA
GROUNDING DETAILS
SHEET NUMBER:' — REVISION:
E3 1
3001CA183
GENERAL STRUCTURAL NOTES 4nt*
Sprint PCS
1, WHERE A CONSTRUCTION DETAIL IS NOT SHOWN OR NOTED, THE DETAIL SHALL GENERAL SIRUCTURAL NOTES:
PROJECT INFORMATION: -
BE THE SAME AS FOR OTHER SIMILAR WORK.
2. NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL
1• ALL WORK SHALL (C IN ACCORDANCE WITH THE ACI JOt -119, ACI 318 -95
16401 LAKESHORE DRIVE
NOTES.
AND THE SPECIFICATION FOR CAST--IN-PLACE CONCRETE.
CURRENT ISSUE DATE:
06/11/02 _j
ISSUED FOR:
3. NO PIPES, DUCTS, SLEEVES, CHASES, ETC., SHALL BE PLACED IN SLABS, 2. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2,500 PSI AT 20
BEAMS, OR WAILS UNLESS SPECIFICALLY SHOWN OR NOTED, NOR SHALL ANY DAYS UNLESS NOTED OTHERWISE.
STRUCTURAL MEMBER BE CUT FOR PIPES, DUCTS, ETC., UNLESS OTHERWISE 3. REINFORCING STEEL SHALL CONFORM TO ASTM A 618 GRADE 60, DEFORMED UNLESS
NOTED. CONTRACTOR SHALL OBTAIN PRIOR APPROVAL FOR INSTALLATION OF NOTED OTHERWISE. WELDED WIRE FABRIC SHALT. CRFORM TO ASTM A 185 WELDED STEEL
ANY ADDITIONAL PIPES, DUCTS, ETC. WIRE FABRIC UNLESS NOTED OTHERWISE. SPLICES CLASS '0' AND ALL HOOKS SHALL BE
4. CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY STANDARD UNLESS NOTED OTHERWISE.
FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT
INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL 4. THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR REINFORCING STEEL
APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS: AND THAT
UNLESS SHOWN OTHERWISE ON DRAWINGS:
THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD SPRINT AND THE CONCRETE CAST AGAINST EARTH ..................... 3 IN.
1
ARCHITECT ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED,
IN CONN WITH THE PERFORMANCE OF WORK ON THIS PROJECI, EXCEPTING FOR CONCRETE EXPOSED TO EARTH OR WEATHER:
V
LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF SPRINT OR THE ARCHITECT /ETMJNEER. 6 AND LARGER ..........................2 IN.
5 AND SMALLER k WAIF .......................... 1 -1/2 IN.
3/4' CHAMFER (IYP.)
4 O 12' O.C. EACH WAY
5. THE CONTRACT DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE.
THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE CONCRETE NOT EXPOSED TO EARTH OR WEATHER OR NOT CAST AGAINST THE GROUND: I_ ALL MEASURES NECESSARY TO PROTECT THE STRUCTURE, WORKERS AND PEDESTRIANS BEAMS AND COLUMNS s' HIGH CONCRETE SLAB
DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT NOT BE LIMITED TD
RAIN BY: CHK.: =APV.:
DRAWN BY: EFS
BRACING, SHORING FOR LOADS DUE TO CONSTRUCTION EQUIPMENT, TEMPORARY
STRUCTURES, AND PARTIALLY COMPLETED WORK, ETC. OBSERVATION VISITS TO THE
5. A CHAMFER 3/4' SFUJL BE PROVIDED AT ALL EXPOSED EDGES OF CONCRETE U.N.O.
IN ACCORDANCE WITH ACI 3U1 SECTION 4.2.4.
24
Y
SITE BY THE ARCHITECT /ENGINEER SH A L NOT INCLUDE INSPECTION OF SUCH ITEMS,
J?
7fE
6. ASiM SPECIFICATIONS NOTED ON THE DRAWINGS SHALL BE OF THE LATEST REVISION.
7. CONSTRUCTION MATERIALS SHALL BE SPREAD OUT IF PLACED ON FRAMED FLOOR OR
RDOF. LOAD SHALL NOT EXCEED THE DESIGN LIVE LOAD PER SQUARE FOOT. PROVIDE
5. HOLES TO RECEIVE E (PA'JON /WEDGE ANCHORS SHNl BE 1 B' LARGER IN DWJETER
THAN THE ANCHOR BOLT, DOWEL DR ROD AND SHALL CONFORM TO MANUFACTURER'S
RECOMMENDATION FOR EMBEDMENT DEPTH OR AS SHOWN ON THE DRAWINGS. LOCATE
AND AVOID CUTTING EXISTING REPAIR WHEN DRIWNG HOLES IN ELEVATED CONCRETE SLABS.
I I- _III — I I- _III —_ -III I -I I I -I I I -- I
III III —II 8 MIL PO Y VAPOR— BARRIER ICON SOIL)
ADEQUATE SHORING/BRACING WHERE STRUCTURE HAS NOT ATTAINED DESIGN STRENGTH. 7, USE AND INSTILLATION OF CONCRETE EXRANSION/WEDGE ANCHOR, SHALL BE PER ICBO do
12' 10' 6' -
NON - ORGANIC FILL COMPACTED
8. R SHALL BE THE RFSPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING MANUFACTURER'S WRITTEN RECOMMENDED PROCEDURES. TO BOLL OF MAX. RELATIVE COMPACTION
UnUffIES WHETHER allOWN HEREON OR NOT AND TO PROTECT THEM FROM DAMAGE. PER ASTM D1157 OR UNDISTURBED S0- 1LSTANDARDTHECONTRACTORSHALLBEMALLEXPENSEOFREPAIRORREPLACEMENTINSTRUCTURALSTEELNOTES: SCARIFY k RECOMPACT TOP 8'
CONJUNCTION WITH THE PROSECUTION OF THIS WORK.
1. ALL METAL WORK SHALL BE IN ACCDRaWCE WITH THE SPECIFICATION
TO BOX OF MAX RELATIVE COMPACTION
PER ASTM D1157
9. DIMENSIONS SFWl TAKE PRECEDENCE OVER SCALES SHOWN ON DRAWINGS. GALVANIZED ASTM A36 UNLESS NOTED OTHERWISE.
10, THESE NOTES SWILL BE CONSIDERED A PART OF THE WRITTEN SPECIFICATIONS. 2. STRUCTURAL TUBING MEMBERS SHALL CONFORM TO ASTM A500, SECTION
11, ALL ITEMS REMOVED DURING CONSTRUCTION WORK Q E., DRYWALL, PLYWOOD, GRADE A OR A501. GALVANIZED ASTM A36 UNLESS NOTED OTHERWISE. A
CEILING PANELS, ETC.) SHALL BE REPLACED TO MATCH EXISTING. 3. ALL WELDING SHALL BE DONE USING E70XX ELECTRODES AND WELDING
12. THE FOLLOWING REQUIREMENTS SHALL BE MET FOR SPECIAL INSPECTION:
SHALL CONFORM TO AISC AND AWS DIA. WHERE FILLET WELD SIZES
ME NOT SHOWN, PROVIDE THE MINIMUM SIZE PER TABLE J2.4 IN THE
A THE SPECIAL INSPECTOR SHALL BE UNDER THE SUPERVI3gN OF A
REGISTERED PROFESSIMIL ENGINEER.
RISC 'MANUAL OF STEEL. CONSTRUCTION', 9TH EDITION.
4. BOLTED CONNECTIONS
I 11' -0•
B. THE SPECIAL INSPECTOR SHALL FURNISH INSPECTION REPORTS TO THE
SWILL USE BEARING TYPE GALVANIZED ASTM A325
BOLTS (3/4' 01A) AND SHALL HAVE A MINIMUM OF TWO BOLTS U.N.O.
THE ARCHITECT/ENGINEER. AND OTHER DESIGNATED PERSONS ALL DISCREPANCIES
SHALL BRR0Ot 1ICCFN, TO THE AT OF THE CONTRACTOR FOR 5. NON-STRUCTURAL CONNECTIONS FOR HANDRAIL, LADDERS AND STEEL ITIUNCORRECTED. THE PROPERCORRECTION; THEN. IF UNCORRECTED. TO THE PHCPER DESGN AUTHORITY AND GRATING MAY USE 5/8' DIA. GALVANIZED ASTM A307 BOLTS U.N.O.
THE BUILDING OFFICIAL.
THE SPECIAL INS' -OR 3HALL SJBAIIT A FINAL REPORT SIGNED BY
BOTH HE AND HIS SUPERVISOR STATING WHETHER THE WORK
REWIRING SPECIAL INSPECTION WAS IN CONFORMANCE WITH THE I /4 te' x te' O EACH CORNER
APPROVED PLANS AND SPECIFICATIONS AND THE APPLICABLE I I TOP AND BOTTOM (TYPO
WORKMANSHIP PROVISIONS OF THE UNIFORM DUPL)ING CODE.
D. COMPLY WITH ALL L Y WECW INSPECTION REQUIREMENTS
Im
I I
tL _ J
FOUNDATION PLAN
L'lOff:
SLOPE CONCRETE SLAB 1% TO DRAIN
AWAY FROM EQUIPMENT CABINET
NOTES SCALE 1 EQUIPAIIENT FOUNDATION °C"' 2REINNONE.
4nt*
Sprint PCS
4683 CHABOT DRIVE, SUITE 100
PLEASANTON, CA 94588
PROJECT INFORMATION: -
HIDDEN PINE
RV64XC517D
16401 LAKESHORE DRIVE
LAKE ELSINORE, CA. 92530
COUNTY OF RIVERSIDE
CURRENT ISSUE DATE:
06/11/02 _j
ISSUED FOR:
CONSTRUCTION
REV.: = DATE: — ISSUED FOR: BY:
1 6/11/02 ONSTRUCTION, 100% V
0 05/10/02 CONSTRUCTION 90% RL
TANS PREPARED BY:
AFL Telecommunications
Wireless Services 126b AL
Pacl(lc 17, Inc Wo (205) R»1 -o717
Fa (206) 941 -3417
ONSULTANT:
RAIN BY: CHK.: =APV.:
DRAWN BY: EFS
LICENSU
m
6u C 054633
rZ*+
Expl_-: _c3
J?
7fE Of
CI
HEFT TITLE:
STRUCTURAL DETAILS
SHEET NUMBER:— REVISION:
S11
3001 CAI 83
GROUND ROD WITH ACCESS • COMPRESSION, CLAMP, OR DOUBLE
11 GROUND ROD
HOLE LUG TYPE GROUND CONNECTION -' -
a EXOTHERMIC CONNECTION CADWELD) TO
GROUND RING AND COMPRESSION TOGROUNDRODGROUNDHALO
L DISCONNECT SW 0• GROUNDING WIRE, DASHED LINE INDICATES
UNDERGROUND
M UTILITY METER -T - TELEPHONE LINE, DASHED LINE INDICATES
UNDERGROUND / \
CIRCUIT BREAKER - -C-- COAXIAL CABLE, DASHED LINE INDICATES -- UNDERGROUND
FUSE - -
A "- ANTENNA COAX
GENERATOR DETAIL REFERENCE
DETAIL N0.2 ON SHEET EJ
SYMBOLS -
ACCA ANTENNA CABLE COVER ASSEMBLY OR GROWTH (
E) METER
AWG AMERICAN WIRE GAUGE IGR INTERIOR GROUND RING (HALO)
BTCW BARE TINNED COPPER WIRE MIGB MASTER ISOLATED GROUND BAR /
C CONDUIT (N) NEW (PROVIDE AND INSTALL
CIGBE COAX INSULATED GROUND UNLESS NOTED OTHERWISE)
BAR EXTERNAL PCS PERSONAL COMMUNICATION SERVICE
CO CONDUIT ONLY PPC POWER PROTECTION CABINET
DWG DRAWING PRC PRIMARY RADIO CABINET _ 0
EAT LLECTR CAL METALLIC TUBING PVC POLYVINYL CHLORIDE CONDUIT
NEW OR EX. EXISTIN3 RGS RIGID GALVANIZED STEEL
GEN GENERATOR RAY RACEWAY
CFI GROUND FAULT CIRCUIT S.L.D. SINGLE LINE DIAGRAM
INTERUPTER SSLP SPRINT SPECTRUM LIMITED PARTNERSHIP
GND GROUND TEL TELEPHONE
CPS GLOBAL POSITIONING SYSTEM TYP. TYPICAL _
WP WEATHERPROOF EQUIPMENT
ABBREVIATIONS
SYMBOLS & ABBREVIATIONS _ 11
PANEL "PP '- 120/240V 10 3W 200A MAIN BREAKER
DESCRIPTION As tal L1 L2 NmMB DESCRIPTION
RADIO EOUPMENT (POWER CABINET) 1
2 2
9.8 IAA 7
8 2
SURGE SUPPRESSOR (INTERNAL)
SPACE 3 9
10 2
FAA LIGHTS (P APPLICABLE)
SPACE 4
GENERATOR CHARGER (NOT USED) 1 5 2 IAA 11 N GFG RECEPTACLE (INTERNAL)
VENT FAN (INTERNAL) 1 1 6 01 12 SPACE
LOAD PHASE 9.81 2
1
1,05/10/02
TOTAL CONNECTED LOAD 10.01KVA/.240 - 41 7A < 200A
1. UTILITY POINTS OF SERVICE AND WORK / MATERIALS SHOWN ARE BASED UPON
PRELIMINARY INFORMATION PROVIDED BY THE UTILITY COMPANIES AND ARE FOR
BID PURPOSES ONLY.
2. CONTRACTOR SHALL COORDINATE WITH UTILITY COMPANY FOR FINAL AND EXACT
WORK / MATERIAIS REQUIREMENTS AND CONSTRUCT TO UTILITY COMPANY
ENGINEERING PLANS AND SPECIFICATIONS ONLY. CONTRACTOR SHALL FURNISH
AND INSTALL ALL CONDUIT, PULL ROPES. CABLES, PULL BOXES, CONCRETE
ENCASEMENT OF CONDUIT CIF REQUIRED), TRANSFORMER PAD, BARRIERS, POLE
RISERS, TRENCHING, BACKFILL, PAY ALL UTILITY COMPANY FEES AND INCLUDE
ALL REOUIREM °NTS IN SCOPE OF WORK.
3. UTILITY CONTACTS FOR THIS PROJECT SHALL BE AS FOLLOWS:
POWER: SDG &E TELEPHONF• PACIFIC BELL
PO BOX 12931 4220 ARIZONA STREET
SAN DIEGO CA. 92112 SAN DIEGO CA 92104
JIM BROWN LINDA THOMPSON
619) 230 -7888 (619) 524 -4326
PANEL SCHEDULE , LMALE:
H41ES:
I. UNDERGROUND SERVICE CONDUIT FROM METER TO POLE, WITH MIN. 3" SAND BASE
30' OF COVER TO FINISH GRADE.
2. ALL BENDS FOR SERV,CE CONDUR TO BE PVC SCHEDULE 80 & 3 FT. RADIUS
SWEEP.
3. NOTIFY SDGE PLANNER PRIOR TO ANY CONSTRUCTION & FIELD VERIFY EXACT
METER LOCATION & RISER QUADRANT AT THE SDGE POWER POLE.
SDGE PLANNER: JAMES BROWN (619) 230 -7888
4. ALL GROUNDINGS FOR METER & TRANSFORMERS MUST BE DONE PER NEC
LOCAL BLDG. & SAFETY REQUIREMENTS.
5. A.I. CONDUIT TRENCHING FROM METER TO THE SITE MUST HAVE MIN. 30'
OF COVER TO FINISH GRADE. INSTALL UNDERGROUND PULL BOXES AS REDD.
PER NEC & LOCAL BLDG. & SAFETY REQUIREMENTS & MUST HAVE TRAFFIC
COVERS.
6. ALL UNDERGROUND PULL BOXES MUST HAVE MW, 2 FT. OF 1' CRUSHED
INDOOR ENT (
RGSDNTOP
OFF BOXXE TO BE 1 1/2' ABOVE FWH GRADE.
7. ALL WIRE SPLICES IN UNDERGROUND PULL BOXES DONE PER NEC.
B. WHEN COMMON TRENCHING IS USED FOR TELCO & POWER MIN. 12' SEPARATION
BETWEEN POWER & TELCO CONDUITS IN THE TRENCH.
9. FIELD VERIFY EXACT TRENCH ROUTE.
10. SPRINT PCS METER PEDESTAL NEED TO BE LABELED & ALL CLEARANCES
FOR ELECTRICAL EQUIPMENT BY NEC.
11. GROUND RODS MAYBE USED FOR SITE GROUNDING IF DESIRED
RESISTANCE IS ACHIEVED.
0
x
21 POWER & TELCO ROUTING
2" C - 3#3/0 + 1 #4 GND
2" C - 3M3/0 + 1N4 GND
POWER PROTECTION CABINET
120/24OV. 1 PHASE, 3 WIRE
MANUFACTURED UNIT, U.L. L
ERVICE ENTRANCE EQUIPMEI
SEE NOTE 9)
NOTE A:
CONTRACTOR TO VERIFY AVAILABLE
AMPACITY, PHYSICAL SPACE FOR NEW
BREAKER, AND VOLTAGE OF EXISTING
POWER PANEL.
I
BATTERY POWER
CABINET I II CABINET
E) POWER PANEL
NEW POWER RUN 1) 2" EMT
W/ 3 0310 & 1 #6 GND
NEW TELCO RUN (1) 4- EMT
2) 2" EMT W/ 3/8'
PULL CORD
NEW EMERGENCY
GENERATOR RECEPTACLE
NEW 200 MAP
METER /MAIN
NEW PPC CABINET
METER /MAIN
NEW MAINTENANCE LIGHT
J
2" EMT - 3 01 & 1 16 CND
TO POWER PANEL "PP' CIRCUIT f1,2
INSTALL NEW 200/2 IN
EXISTING POWER PANEL (SEE
NOTE A)
200 A METER BASE
SEE NOTE 7)
200A EMERGENCY GENERATOR PLUG
04 GND
200A WALKING BEAM INTERLOCK BREAKERS
10,000 AIC (DOUBLE THROW TRANSFER SWITCH)
POWER PANEL "PP" INSIDE "PPC", 10,000 AIC
ALL BREAKERS ARE FACTORY INSTALLED)
2" C - 3#1 AWG + 106 CND
NEW DEMARCATION
CABINET (WALL MOUNTED
PER VERIZON SPECIFICATIONS)
UUMN
DIAL TOLL FREE
1- 800 - 422 -4133
AT LEAST TWO DAYS
BEEFORE YOU DID
UNI MGMIIU SERVICE A1ERY OF SOUn1EM CAAFOWIW
mm:
1. POWER TO SPRINT EQUIPMENT SHALL BE 2000. 120/24GV, 10, 3W.
2. UTILITY RECEPTACLE IS A GFCI DUPLEX OUTLET INSTALLED IN THE
DEADFRONT OF THE PPC.
3. FOR COMPLETE INTERNAL WIRING AND ARRANGEMENTS REFER TO
VENDOR PRINTS BY PPC MANUFACTURER NORTHERN TECHNOLOGIES,
PART NO. N2101 -WO1, U. L. LISTED,
4. PROVIDE A MIN. OF 38' WORK CLEARANCE IN FRONT OF PANELS
AND SERVICE EQUIPMENT.
5. ALL WIRING SHALL BE COPPER RATED FOR 75' C.
6. CONDUIT REQUIREMENTS (TYP. U.N.J.)
UNDERGROUND: PVC (SCHED. 40 OR 80)
INDOOR: EMT (RGS IN TRAFFIC AREAS)
OUTDOOR (ABOVE GRADE): RGS
ADJUST CONDUIT FILL FOR SCHEDULE 80 PVC CONDUITS)
7. SERVICE METER SHALL BE RATED FOR 42,000 AIC,
8. DISCONNECT THE FACTORY MAIN BONDING JUMPER BETWEEN THE
NEUTRAL AND THE GROUND BUS IN THE PPC. PROVIDE NEUTRAL TO
GROUND BONDING AT THE SERVICE METER.
9. "PPC" CABINET IS RATED FOR 10,000 AC.
10. PROVIDE CURRENT LIMITING FUSES TO REDUCE THE INSTANTEOUS
PEAK LET- THROUGH CURRENT TO LESS THAN 10,000 AIC. LOCATE
BELOW SERVICE PANEL. PROVIDE 4 SPARE FUSES. USE BUSMANN
AJJN OR EQUIVALENT.
41
I[ UTILITY GENERAL NOTES „;Je 3 1 ELECTRICAL 1 -LINE DIAGRAM I °
E, 511
Sprint PCS "
I I11 i _ I/
I
I
CABINETT
I
I
I
CABINETT
I
I
I
COUNTY OF RIVERSIDE
CURRENT ISSUE DATE:
06/11/02
ISSUED FOR:
CONSTRUCTION
EV.:--DATE:- ISSUED FOR: BY:-
2" C - 3#3/0 + 1 #4 GND
2" C - 3M3/0 + 1N4 GND
POWER PROTECTION CABINET
120/24OV. 1 PHASE, 3 WIRE
MANUFACTURED UNIT, U.L. L
ERVICE ENTRANCE EQUIPMEI
SEE NOTE 9)
NOTE A:
CONTRACTOR TO VERIFY AVAILABLE
AMPACITY, PHYSICAL SPACE FOR NEW
BREAKER, AND VOLTAGE OF EXISTING
POWER PANEL.
I
BATTERY POWER
CABINET I II CABINET
E) POWER PANEL
NEW POWER RUN 1) 2" EMT
W/ 3 0310 & 1 #6 GND
NEW TELCO RUN (1) 4- EMT
2) 2" EMT W/ 3/8'
PULL CORD
NEW EMERGENCY
GENERATOR RECEPTACLE
NEW 200 MAP
METER /MAIN
NEW PPC CABINET
METER /MAIN
NEW MAINTENANCE LIGHT
J
2" EMT - 3 01 & 1 16 CND
TO POWER PANEL "PP' CIRCUIT f1,2
INSTALL NEW 200/2 IN
EXISTING POWER PANEL (SEE
NOTE A)
200 A METER BASE
SEE NOTE 7)
200A EMERGENCY GENERATOR PLUG
04 GND
200A WALKING BEAM INTERLOCK BREAKERS
10,000 AIC (DOUBLE THROW TRANSFER SWITCH)
POWER PANEL "PP" INSIDE "PPC", 10,000 AIC
ALL BREAKERS ARE FACTORY INSTALLED)
2" C - 3#1 AWG + 106 CND
NEW DEMARCATION
CABINET (WALL MOUNTED
PER VERIZON SPECIFICATIONS)
UUMN
DIAL TOLL FREE
1- 800 - 422 -4133
AT LEAST TWO DAYS
BEEFORE YOU DID
UNI MGMIIU SERVICE A1ERY OF SOUn1EM CAAFOWIW
mm:
1. POWER TO SPRINT EQUIPMENT SHALL BE 2000. 120/24GV, 10, 3W.
2. UTILITY RECEPTACLE IS A GFCI DUPLEX OUTLET INSTALLED IN THE
DEADFRONT OF THE PPC.
3. FOR COMPLETE INTERNAL WIRING AND ARRANGEMENTS REFER TO
VENDOR PRINTS BY PPC MANUFACTURER NORTHERN TECHNOLOGIES,
PART NO. N2101 -WO1, U. L. LISTED,
4. PROVIDE A MIN. OF 38' WORK CLEARANCE IN FRONT OF PANELS
AND SERVICE EQUIPMENT.
5. ALL WIRING SHALL BE COPPER RATED FOR 75' C.
6. CONDUIT REQUIREMENTS (TYP. U.N.J.)
UNDERGROUND: PVC (SCHED. 40 OR 80)
INDOOR: EMT (RGS IN TRAFFIC AREAS)
OUTDOOR (ABOVE GRADE): RGS
ADJUST CONDUIT FILL FOR SCHEDULE 80 PVC CONDUITS)
7. SERVICE METER SHALL BE RATED FOR 42,000 AIC,
8. DISCONNECT THE FACTORY MAIN BONDING JUMPER BETWEEN THE
NEUTRAL AND THE GROUND BUS IN THE PPC. PROVIDE NEUTRAL TO
GROUND BONDING AT THE SERVICE METER.
9. "PPC" CABINET IS RATED FOR 10,000 AC.
10. PROVIDE CURRENT LIMITING FUSES TO REDUCE THE INSTANTEOUS
PEAK LET- THROUGH CURRENT TO LESS THAN 10,000 AIC. LOCATE
BELOW SERVICE PANEL. PROVIDE 4 SPARE FUSES. USE BUSMANN
AJJN OR EQUIVALENT.
41
I[ UTILITY GENERAL NOTES „;Je 3 1 ELECTRICAL 1 -LINE DIAGRAM I °
E, 511
Sprint PCS "
4883 CHABOT DRIVE, SUITE 100
PLEASANTON, CA 94588
PROJECT INFORMATION:
HIDDEN PINE
RV54XC517D
16401 LAKESHORE DRIVE
LAKE ELSINORE, CA. 92530
COUNTY OF RIVERSIDE
CURRENT ISSUE DATE:
06/11/02
ISSUED FOR:
CONSTRUCTION
EV.:--DATE:- ISSUED FOR: BY:-
1
1,05/10/02
08/11/02 CONSTRUCTION, 100 SJV
CONSTRUCTION 90x RL
LANS PREPARED BY:
I IL AFL Telecommunications
Wireless Services '200 7J'P'''1 Oft sw T70
ti K 36742
Pacific 17, Inc QW" (21" W-0717
Fa (706) 01 -3417
ONSULTANT:
Room &**K% unc-
Mid d "w A•ft &OW
row r•ra
2101.077.33
is lumii m-ra v. elan ax
RAWN BY: CHK.: =APV.:
DRAWN BY- SJV I SJV RL
CENSURE:
Y E89Ay,_
4
4
Eqp LUM •
My' 1Gla' tie
a CA
SHEET TITLE:
POWER AND
TELCO ROUTING
SHEET NUMBER: -- REVISION:
El 1
3001CAI83
CONCRETE PAD,
A* 't s
Sprint PCs'+ FINISHED GRADE OR SURFACING TO
SHEET 7 FOR DIMENSIONS 5/8'0 X 10 COPPER CLAD
PLEASANTON, CA 94588
MATCH EXISTING (A.C., CONCRETE, ETC.)
PROJECT INFORMATION:
r—
GROUND ROD (TYP.)
RV54XC517D
16401 LAKESHORE DRIVE
LAKE ELSINORE, CA. 92530
COUNTY OF RIVERSIDE
CURRENT ISSUE DATE:
06/11/02
SSUED FOR:
CONSTRUCTION
EXOTHERMIC WELD AT 12' MIN. RADIUS
BURIED GROUND RING (TYP.)
PER PLAN
WIDTH VARIES
12' MIN.)
COMPRESSION TYPE TWO -HOLE BE UNDISTURBED
LONG BARREL GROUNDING FITTING,
1 06/11/02
0
MOD 0.75' O.C. LUGS (FOR #2 AWG
CONSTRUCTION 907E JLL
T
COMPACTED BACKFILL PER
Wireless Services t"00w ho AL
POWER CELL SOLID COPPER CONDUCTOR
ONSULTANT:
i SITEWORK SPECIFICATIONS
Dom
DRAWN BY: CHK.: =APV.:
DRAWN BY: SJV I SJV RL
CENSURE:
1pFE7S,
44
112 AWG SOLID TINNED BARE
TR1G
cAJ
ro n BACKFILL (SAND OR NATIVE SOIL)
COPPER CONDUCTOR FOR io 1' -0' 6' PER EARTHWORK SPECIFICATIONS
EQUIPMENT ENCLOSURE BOND I
15' MAX. (TYP.)
a
UTILITY WARNING TAPE
COAX CABLE 2
02 AWG SOLID TINNED BARE SEE CABLE SCHEDU
ES
C5
COPPER GROUND CONDUCTOR FOR COAX SIZE
IF UNDERGROUND COAXIRNRX
4- X 1/4' X 24' LENGTH REQUIRED TINNED
COPPER MAIN GROUND BAR (MGB). MOUNT
MGB ON RFU /BBU RACK 1. PULL BOXES INSTALLED PER
LOCAL UTILITY REQUIREMENTS.
2. SEPARATION DIMENSION TO BE VERIRED 6' MIN. NOTE:
1. FOR NUMBER OF GROUNDING RODS REQUIRED, WITH LOCAL UTIL(
TYP.)
ITY COMPANY REQUIREMENTS. 3' PVC ELECTRICAL CONDUIT
REFER TO 16000 & SSLP REQUIREMENT. 3. WHERE ONLY ONE (1) CONDUIT IS INSTALLED. 4' PVC TELEPHONE CONDUIT
2. ENLARGED MIGB SHOWN FOR CLARITY TO DEPICT MINIMUM TRENCH WIDTH SHALL BE 12'.
REQUIRED CONDUCTORS TO THE BAR.
3. LOCATION OF THE MIGB'S TO BE DETERMINED
IN THE FIELD AND MAY BE LOCATED AND SUPPORTED
AS CLOSE TO THE EQUIPMENT AS FEASIBLE AND
PRACTICAL TO ACHIEVE CONFIGURATIONS.
EQUIPMENT GROUNDING 1 UNDERGROUND UTILITY CONDUIT DETAIL (JOINT TRENCHING)
SCALU 141
NONE
NONE
GRADE
SEE NOTE 1 CADWELD
GROUND RING
172 WAG BCW
GROUND ROD COPPERWELD
5/8'0 X10' -0' LONG
NOTE:
1. APPROXIMATE DIMENSION SHALL
BE THE GREATER DEPTH OF 18'
OR 6' BELOW FROST LINE
GROUND ROD DETAIL 2 NOT USED 5
IA
TO EQUIPMENT GROUND RING -
CONCRETE SLAB
ORIENT SLEEVE TO ACHIEVE.
f
SMOOTH BEND RADIUS FOR
GROUND WIRE
6'
2' PVC SCHEDULE 40 SLEEVE
TO BURIED GROUND RING
IF REQUIRED TO ROUTE GROUND WIRE THROUGH SLAB
SLEEVE DETAIL INK 3 NOT USED Name
s
A* 't s
Sprint PCs'+
4883 CHABOT DRIVE, SUITE 100
PLEASANTON, CA 94588
PROJECT INFORMATION:
HIDDEN PINE
RV54XC517D
16401 LAKESHORE DRIVE
LAKE ELSINORE, CA. 92530
COUNTY OF RIVERSIDE
CURRENT ISSUE DATE:
06/11/02
SSUED FOR:
CONSTRUCTION
REV.: DATE: SSUED FOR: BY:
1 06/11/02 ONSTRUCTION, 10034 SJV
0 05/10/02 CONSTRUCTION 907E JLL
PLANS PREPARED BY:
AFL Telecommunications
Wireless Services t"00w ho AL
Pacific 17, Inc 0180 0" "1-m
Fa (706) 01 -3417
ONSULTANT:
OMEM EnyineeM Inc.
ra.wrad" a ft seem
R" ftow
z1o+.ois..v
Dom
DRAWN BY: CHK.: =APV.:
DRAWN BY: SJV I SJV RL
CENSURE:
1pFE7S,
44
En. 6/70/04 •
TR1G
cAJ
SHEET TITLE:
DETAILS
HEET NUMBER:REVISION:
E4 1
30010.4183