Loading...
HomeMy WebLinkAboutCENTRAL AVE 29261_14-00002838CITY OF 09 LSIN.OR I BUILDING & SAFETY te=a' DREAM EXTREME 7M PERMIT 130 South Main Street PERMIT NO: 14- 00002838 JOB ADDRESS • 29261 CENTRAL AVE SUITE #C DESCRIPTION OF WORK . : SIGN DATE: 10/27/14 OWNER CONTRACTOR LAKE ELSINORE MARKET PLACE CLEAR SIGN & DESIGN, INC. 29273 CENTRAL AVENUE SUITE B 170 NAVAJO ST. LAKE ELSINORE CA 92530 SAN MARCOS CA 92078 760 - 736 -8111 LIC EXP 0 /00 /00 A.P.# . . . . . : 377 - 040 -027 2 SQUARE FOOTAGE . . OCCUPANCY GARAGE SQ FT . . . CONSTRUCTION . . : FIRE SPRNKLR . . VALUATION 20,000 ZONE NA 0 0 ELECTRICAL PERMIT QTY UNIT CHG ITEM CHARGE BASE FEE 30.00 2.00 X 21.0000 SIGNS 42.00 SIGN PERMIT QTY UNIT CHG ITEM CHARGE BASE FEE 63.00 18.00 X 12.5000 VALUATION 225.00 FEE SUMMARY PERMIT FEES ELECTRICAL PERMIT SIGN PERMIT OTHER FEES PROF.DEV.FEE 2 TRADES PLAN RETENTION FEE GREEN BUILDING FEE 1 PLAN CHECK FEES TOTAL SPECIAL NOTES & CONDITIONS REMOVE & REPLACE (2) EXISTING ILLUMINATED WALL SIGNS CHARGES 72.00 288.00 10.00 2.86 1.00 187.20 561.06 PAID 00 00 00 00 00 00 00 DUE 72.00 288.00 10.00 2.86 1.00 187.20 561.06 O N' Date: g, ,.;_i 14. _ Receipt ;t Dna BU VC VISA mu Total Tendered lath! pa,,.,_,;.._t City of Lake Elsinore Building Safety Division Post in conspicuous place on the job You must furnish PERMIT NUMBER and the JOB ADDRESS for each respective inspection: Approved plans must be on job at all times: Please read and initial T am Licensed under the provisions of Business and professional Code Section 7000 et seq. and my license is in full force. 2. I,as owner of the property,or my employees w /wages as their sole compensation will do the work and the structure is not intended or offered for sale. 3. I,as owner of the property,arn exclusively contracting with licensed contractors to construct the r project. 6 . I have a certificate of consent to selfinsure or a certificate of Workers Compensation Insurance or a certified copy thereof. 5. I shall not employ any person in any manner so as to become subject to Workers Compensation Laws in the performance of the work for which this permit is issued. Note: If you should become subject to Workers Compensation after making this certification, Code Approvals Date Inspector you must forthwith comply with such provisions or this permit shall be deemed revoked. EL01 Temporary Electric Service PL01 Soil Pipe Underground EL02 Electric Conduit Underground BPO 1 Footings BP02 Steel Reinforcement BP03 Grout BP04 Slab Grade PLO 1 Underground Water Pipe SSO1 Rough Septic System SW01 On Site Sewer BP05 Floor Joists BP06 Floor Sheathing BP07 Roof Framing BP08 Roof Sheathing BP09 Shear Wall & Pre -Lath PL03 Rough Plumbing EL03 Rough Electric Conduit EL04 Rough Electric Wiring ELO5 Rough Electric / T -Bar ME01 Rough Mechanical ME02 Ducts, Ventilating PL04 Rough Gas Pipe / Test PL02 Roof Drains BP 10 Framing & Flashing BP I2 Insulation BP13 Drywall Nailing BP 11 Lathing & Siding PL99 Final Plumbing EL99 Final Electrical 23 *MI ca. ME99 Final Mechanical BP99 Final Building i2•23' /ef Aig OTHER DIVISION RELEASES Code Pool & Spa Approvals Date Inspector Department Approval required prior to the building being released by the City SPO1 Electric Conduit UG SP02 UG Gas Piping SP03 Pool Steel Rein./Fornrs Date Inspector SP04 Pool Plmb./Pressure Test PlanningSP05Pre - Gunite Approval Landscape SP06 Rough Pool Electric Finance SP07 Pool Fence /Gates /Alarms EngineeringSP08Pre- Plaster Approval SP99 Final Pool / Spa CITY OF LADE DREAM EXTREME TM APPLICATION FOR BUILDING PERMIT VALUATION CALCULATIONS 1st FLOOR SF 2nd FLOOR SF 3rd FLOOR SF GARAGE SF STORAGE SF DECK & BALCONIES SF OTHER: SF VALUATION: °1 c g (CO FEES BUILDING PERMIT $ PLAN CHECK PLAN REVIEW SEISMIC PLAN RETENTION certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city enter upon the above - mentioned property for insp- tior' •urooses. Signature of Applicant or Agent Date Agent for p contractor owner Agents Name Agents Address v.a vaa.w 130 South Main Street APPICAtTION NO. b APPLIC A(TIr0)1 2 -F E ` DATE (Uf / //( 1 BY I( H.- AP #'- 77---? -o Li 0 -0D-7 BUILDING ADDRESS 377.,r6 yI•- 63/5 TIjCT BLOCK/PAGE LOT /PARCEL lam 3 z 5& Pjn9c.9 /3y 'V o W N E R NAME 2- CO )11 n1EaC AL C O N T R A C T o R I hereby affirm that I am licensed under provisions of chapter 9 (commencing with section 7000) of division 3 of the business and professions code,and my license is in full force and effect. LICENSE # 7£ f 9 5 q CITY BUSINESS AND CLASS C Jd , cy S TAX # (75,? di NAME 5'T is Whra0 ELL -C=L 1t7Z I- 6, '5,- MAILING ADDRESS d 74 ,NI AV A T. 5 T- CITY STATE /ZIP PHONE Ca< W.0 rl ?0 —73'' 3 / i / T • •''S SIGNATU u kIEf4 • Li A R C H NAME LICENSE # MAILING ADDRESS CITY STATE /ZIP PHONE NEW OCC GRP. / CONST. DIVISION: TYPE: ADDITION ALTERATION NUMBER OF NUMBER OF STORIES: BEDROOMS: OTHER SINGLE FAMILY ZONE: APARTMENTS Cl CONDOMINIUMS HAZARD YES AREA ? NOTOWNHOMES COMMERCIAL SPRINKLERS YES REQUIRED ? NOINDUSTRIAL REPAIR PROPOSED USE OF BLDG: C- R 3- (J fki •'ij J PRESENT USE OF BLDG: C a it ;4 £J :J>i pA! DEMOLISH JOB DESCRIPTION 12.0 »'+d nC d- /20F/1-AC1: (Z.) 4xeS7i4)6- TL4.0lni itfj7F -D LEALL ,6. . STATE OF CALIFORNIA SIGN LIGHTING CEC- NRCC- LTS- 01- E(Revised 06/14 CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE N RCC- LTS -01 -E Sign Lighting Project Name: ki AVN fLnGIj2,,.g L Page 1 of 5) Date Prepared: Project Address: Location of Sign t 1 tdoor Signs Phase of Sign Construction New Signs Type of Lighting Control New Lighting Controls sry C? 2S 3 Indoor Signs Sign Alterations Replaced Lighting Controls Not Installing Lighting Controls This Certificate of Compliance includes the following components (check all that apply) Mandatory Measures (Lighting Controls) Maximum Allowed Lighting Power Specific Lighting Sources 1. Mandatory Sign Lighting Controls NOTES: 1. The some responsible person may install both the sign lighting power and the sign lighting controls, or a different responsible person may install the sign lighting controls than the responsible person installing the sign lighting power. 2. The Mandatory Measures (sign lighting controls) are required for compliance with the sign lighting Standards. If the person responsible for installing the sign lighting power is not also responsible for the sign lighting controls, then the owner of the sign, general contractor, or architect shall be responsible to have the sign lighting controls installed. 3. If more than one person has responsibility for compliance, each responsible person shall prepare and sign a Certificate of Compliance and an Installation Certificate applicable to the portion of construction for which they are responsible; alternatively, the person with chief responsibility for construction shall prepare and sign the Certificate of Compliance Declaration Statement for the entire construction. la. Statements of Responsibility: Any person signing the Certificate of Compliance Declaration Statement on this NRCC - LTS -01 -E shall complete Part la. Check Yes or No for all of the following statements: 1 I have responsibility for installing the sign lighting control Yes, complete parts la and 1b of this form fd" No, complete part la of this form 2 There are no existing sign lighting controls and I will be ins (ling compliant sign lighting controls Yes IZNo 3 The are no existing sign lighting controls and someone else will be responsible to install compliant sign lighting controls i2 Yes No 4 There are existing sign lighting controls that do not comply with the applicable provision of §110.9 and §130.3 and I will be installing compliant sign lighting controls Yes ET/No 5 There are existing sign lighting controls that do not comply with the applicable provision of §110.9 and §130.3 and someone else will be responsible to install compliant sign lighting corols Yes leii No CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014 STATE OF CALIFORNIA SIGN LIGHTING CEC- NRCC- LTS- 01- E(Revised 06/14 CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-LTS-01-E Sign Lighting Page 2 of 5) Project Name: Date Prepared: 1b. Mandatory Sign Lighting Controls If the person signing the Certificate of Compliance Declaration Statement on this NRCC - LTS -01 -E is responsible for complying with the sign lighting control requirements, that person shall answer all of the following questions: /" If there are construction documents, indicate where on the building plans the mandatory measures (sign lighting control) note block can be located: 1 130.3(a)1. All indoor sign lighting is controlled with an automatic time - switch contr, or astronomical time- switch control. Y N NA 2 130.3(a)2A. All outdoor sign lighting is controlled with a photocontrol in addiiU6n to an automatic time- switch control, or an astronomical time - switch control. l Y N NA EXCEPTION to Section 130.3(a)2A: Outdoor signs in tunnels, and signs in I ; ge permanently covered outdoor areas that are intended to be continuously lit, 24 hours per day and 365 ays per year. Y NA 3 130.3(a)2B. All outdoor sign lighting that is ON both day and night is controlled with a dimmer that provides the ability to automatically reduce sign lighting power by a minimu /of 65 percent during nighttime hours. Signs that are illuminated at night and for more than 1 hour duri daylight hours shall be considered ON both day and night. Y 0 z NA EXCEPTION to Section 130.3(a)2B: Outdoor signs in tunnels a /d large covered areas that are intended to be illuminated both day and night. Y NA 4 130.3(a)3. Demand Responsive Electronic Message Ce er Control. An Electronic Message Center (EMC) having a new connected lighting power load greater th.,' 15 kW has a control installed that is capable of reducing the lighting power by a minimum of 30 perc - - "t when receiving a demand response signal. Y N N/A EXCEPTION to Section 130.3(a)3: Lighting for EMCs at is not permitted by a health or life safety statute, ordinance, or regulation to be reduced by 30 perc 't. Y NA Field Inspector Notes: CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014 STATE OF CALIFORNIA SIGN LIGHTING CEC- NRCC- LTS- 01- E(Revised 06/14 CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE N RCC- LTS -01 -E Sign Lighting Page 3 of 5) Project Name: Date Prepared: 2. Maximum Allowed Lighting Power Method of Compliance Checklist maximum allowed lighting power method of compliance. using the Specific lighting sources method of comp Complete part 3 of lance) Certificate of Compliance and Field Inspection Energy Complete this part if there are signs using the this Certificate of Compliance if there are signs A B C D I E I F I G H I 1 S mboly Or Code Description of the Sign OPTIONAL — Energy Verified Label (see instructions below) Allotted Watts Design Watts Complies Y / N Filed Inspector Check that sign complies SignArea (ft2) Internally ( I) or Externally ( E) Illuminated AllowedLPD I — 12 W / ft2) E = 2. 3 W / ft2) AllowedWas DxF) Totai\installed watts\forsign 9 5 HKJ! salldwo3 A Symbol or code used o the plans (when plans are requi ed) and other documents. B A description of the n, or location of sign on the building; and the location of sign on construction documents. OPTIONAL - Chec his box sign complies wi he Section only if this sign has a permanent, pre - printed, factory - installed, ENERGY VERIFIED label, confirming that the 140.8 of the California 2013 Title 24, Part 6 Standards, using the Maximum Allowed Lighting Power only labels that will be recognized for this purpose are ENERGY VERIFIED Certification Marks authorized by UL) or other Product Certification Body accredited to ISO /IEC Guide 65 by the American National Standards ISO /IEC 17011. Surveillance by the Accredited Certification Body shall be an ongoing annual inspection Type A Inspection body in accordance with ISO /IEC 17020. For signs with such an ENERGY VERIFIED label, not required to be filled out. Note: Using an ENERGY VERIFIED label is an optional method to validate label is not needed for compliance. method of compliance. The Underwriters Laboratories Institute in accordance with program carried out by a columns 'D' through 'I' are compliance. An ENERGY VERIFIED D The sign area in square feet. E List "I" if the sign is internally illuminated. List "E" if the sign is externally illuminated. F Allowed watts per square foot. Enter 12 if the sign is listed as "I" in column E. Enter 2.3 if sign is listed as "E" in column E. G Multiply the square footage in column D times the allowed Lighting Power Density (LPD = watts) in column F. H Show the total installed watts in the sign, as determined according to the applicable provisions of §130(c). I Enter Y if the number in column H is less than or equal to the number in column G. Otherwise, the sign does not comply. J This page doubles as a field inspection checklist. Field Inspector Notes: CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014 STATE OF CALIFORNIA SIGN LIGHTING CEC- NRCC- LTS- 01- E(Revised 06/14 CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-LTS-01-E Sign Lighting Page 4 of 5) Project Name: Date Prepared: 3. Specific Lighting Source Method of Compliance Certificate of Compliance and Field Inspection Energy Checklist Complete this part if there are signs using the Specific lighting source method of compliance. (Complete part 2 of this Certificate of Compliance if there are signs using the maximum allowed lighting power method of compliance) A B C D E Symbol or Code Description OPTIONAL Specific light source used for compliance Shall include only lighting technologies listed below List all that apply Field Inspector Check that Sign Complies ENERGY VERIFIED label see instructions below) 1 Lilo i forel WA-Li, `J ,P.)S 7 t g A Symbol or code used on the plans (when plans are required) and other documents. B A narrative description of the sign, or location of sign on the building; and the location of sign on construction documents C OPTIONAL - Check this box only if this sign has a permanent, pre - printed, factory - installed ENERGY VERIFIED label, confirming that this sign complies with the Section 140.8 of the California 2013 Title 24, Part 6 Standards, using the Specific Lighting Source Method of Compliance. The only labels that will be recognized for this purpose are ENERGY VERIFIED Certification Marks authorized by Underwriters Laboratories (UL) or other Product Certification Body accredited to ISO /IEC Guide 65 by the American National Standards Institute in accordance with ISO /IEC 17011. Surveillance by the Accredited Certification Body shall be an ongoing annual inspection program carried out by a Type A Inspection body in accordance with ISO /IEC 17020. For signs with such an ENERGY VERIFIED label, column 'D' is not required to be filled out. Note: Using an ENERGY VERIFIED label is an optional method to validate compliance. An ENERGY VERIFIED label is not needed for compliance. D Specific Light Source Compliance Method. The sign(s) identified above use only the following lighting technologies: List all applicable numbers (1 through 9) that apply in column D above for each row. 1 High pressure sodium lamps 2 Metal halide lamps that are pulse start or ceramic served by a ballast that has a minimum efficiency of 88 percent or greater. Ballast efficiency is the measured output wattage to the lamp divided by the measured operating input wattage when tested according to ANSI C82.6 -2005. 3 Metal halide lamps that are pulse start that are 320 watts or smaller, are not 250 watt or 175 watt lamps, and are served by a ballast that has a minimum efficiency of 80 percent. Ballast efficiency is the measured output wattage to the lamp divided by the measured operating input wattage when tested according to ANSI C82.6 -2005. 4 Neon or cold cathode lamps with transformer or power supply efficiency greater than or equal to a minimum efficiency of 75 percent when the transformer or power supply rated output current is less than 50 mA. The ratio of the output wattage to the input wattage is at 100 percent tubing load. 5 Neon or cold cathode lamps with transformer or power supply efficiency greater than or equal to a minimum efficiency of 68 percent when the transformer or power supply rated output current is 50 mA or greater. The ratio of the output wattage to the input wattage is at 100 percent tubing load. 6 Fluorescent lighting systems meeting one of the following requirements: A. Use only lamps with a minimum color rendering index (CRI) of 80; or B. Use only electronic ballasts with a fundamental output frequency not less than 20 kHz. 7 Light emitting diodes (LEDs) with a power supply having an efficiency of 80 percent or greater; 8 Single voltage external power supplies that are designed to convert 120 volt AC input into lower voltage DC or AC output, and have a nameplate output power less than or equal to 250 watts, shall comply with the applicable requirements of the Appliance Efficiency Regulations (Title 20). 9 Compact fluorescent lamps that do not contain a medium screw base sockets (E24/E26). E This page doubles as a field inspection checklist. Field Inspector Notes: CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014 STATE OF CALIFORNIA SIGN LIGHTING CEC- NRCC- LTS- 01- E(Revised 06/14 CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC - LTS -01 -E Sign Lighting Page 5 of 5) Project Name: Date Prepared: DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. / Documentation Author Name: ii 1.1) to 6z Lz_ Documentation Author Signa re• Company: l— tJ i l e) '7 y ES 0k Signature Date: i / , p Address: t ,,, 1<JA UA3 5r CEA/ HERS Certification Identification (if applicable): City /State /Zip: 1 ill i 2 c 1i Z/ 7gr Phone: 7 (0G -? 36 — .:''' 1 it RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. I will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name: Responsible Designer Signature: Company : Date Signed: Address: License: City /State /Zip: Phone: CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2014 kgg;,:..g,gN:::!tmgnw:RN,.00aqt-,,,sg,,,Eg.,g:.,NzadgaA.ggmka,A,a:,!-,M.E;Mg:NM-gg.:E:fpgaaaM;N.EgtN:MagRgRiVManugagMFMRM.MaEggi:YANSMMg::Vgig,Z;:ARV:sggggag2VS!;,NS'aiEgigagain:eigfMM:MRENE.!Pgiggi.S:t'MZMNSMRRSnfd'MNS-:Mkaf:ggg:Mg:MfaiegSa:FnrMNNNVIVNM:nqErggiignfntg:EtaT:NEVRVNS:titfiganSanMs'gag::RSMZN83RNRVeEgatg'Ngnta::RgnriatZ:g,RN., City of Lake Elsinore Planning iwis *',) Approval Approved By: _ Date: ?•-c? ArredOcvb FOn----2- 1'4 1P-vTa17) NAVY FEDERAL 29261 Central Ave. Ste. C Lake Elsinore, CA 92532 PAGE INDEX Sign A - North Elevation 1 Sign B - South Elevation 2 Channel Letter Details 3 IN L2 SIGN DESIGN, INC. 170 NAVAJO STREET SAN MARCOS, CA 92078 t) 7 6 0 . 7 3 6 . 8 1 1 1 ( f ) 7 6 0 . 7 3 6 . 8 1 2 1 COPYRIGHT @ 2009 Clear Sign & Design, Inc. RE SCALE: 9/64"=11' NFCU - Lake Elsinore • 14089 WiaMialltMASi8 N i•••••• :.......H.•••••• • • JN 1 SIGN A Existing North Elevation Signage DAM SIGN DESIGN, INC. 170 NAVAJO STREET SAN MARCOS, CA 92078 t) 780.736.8111 (f) 760.738.8121 COPYRIGHT 02009 Clear Sign A Dengn, Inc. Lic 4: 745954 This drewing end the concepts it represents era the solo property of Clear Sign & Design, Inc end may not be reproduced by any method without the written permission of Clear Sign & Design, Inc. Approved I I Approved as Noted Signature: Data Client Name & Number Job Location NFCU 29261 Central Ave. Ste. C C05911 Lake Elsinore, CA 92532 Design Number Personnel 14089 NFCU-Lake Elsinore - 9-29-14 Salesperson: SJW Project Manager: LA NAVY FEDERAL 9261 C). t3dB klif Date/Revision/Description 9-25-14 Initial Design-TL 9-29-14 Changed out photos SIGN A Proposed New North Elevation Signage 1 of 3 SCALE: 9/64"=1' NFCU - Lake Elsinore • 14089 NAVY RED.,1,,AL ORfill),17 (NON k •• 9 SIGN B Existing South Elevation Signage AO @nu SIGN min D ES IGN , INC. 170 NAVAJO STREET SAN MARCOS. CA 92078 t) 760.736.8111 (f) 760.738.8121 COPSOIGHT4 2009 Clear $19n 0 Design, Inc. Lic #1745954 This dravring end the concepts 0 represents ore the sole property of Clear Sign & Design, Inc and mey not be reproduced by any method without the written pennission of Clear Sign & Design. Inc. lApproved Approved as Noted Signature: Date: Client Name & Number NFCU C05911 Job Location 29261 Central Ave. Ste. C Lake Elsinore, CA 92532 Design Number Personnel 14089 NFCU-Lake Elsinore - 9-29-14 Salesperson: SJW Project Manager: LA 7:F;') NAVY FEDERAL SIGN B 16- __--Proposed New South Elevation Signage Date/Revision / Description 9-25-14 Initial Design - TL 9-29-14 Changed out photos 2 of 3 SCALE: 1/4 "= NFCU - Lake Elsinore • 14089 0 North & South Channel Letters Internally illuminated channel letters built to UL specification Quantity: Two (2) Overall height of sign: 2' - 0" Overall length of sign: 19' - 10" Total square feet: 39.67' Construction: 1: Channel Letters: 5" deep aluminum channel plaques, 3/16" white acrylic face with 3630 -36 (PMS 540c Blue) Translucent Blue vinyl overlay, White trimcap and returns, White LEDs 2: Mounting Method: Mount flush to wall. Minimum 3 fasteners per letter 40 ©IRAQ SIGN DESIGN, INC. 170 NAVAJO STREET SAN MARCOS, CA 92078 t) 760.736.9111 (f) 760.736.6121 COPYRIGHT SS 2009 CI., Sign & Design, Inc, Lic #: 745954 This drawing and the concepts it represents are the sole property of Clear Sign & Design, Inc and may not be reproduced by any method without the written pennies on of Clear Sign & Design. Inc. i Approved , Approved as Noted Signature:..... _..... ___. Data:..... _.... NFCU C05911 Client Name & Number Job Location 29261 Central Ave. Ste. C II Lake Elsinore, CA 92532 Design Number ! Personnel 14089 NFCU -Lake Elsinore - 9 -29 -14 Salesperson: SJW Project Manager: LA Date / Revision / Description 9 -25 -14 Initial Design - TL 9 -29 -14 Changed out photos 3M 3630 -36 Blue Trans. Vinyl INDIVIDUALLY - MOUNTED CHANNEL LETTERS 8X3 /4'SSSCREWPAINTEDTO MATCHRETURNCOLOR 0907HK.BACKSWITH 063'THK.RETURNS. 3/1 6'THK. # 7326 W H ITEACRYLIC INSIDEPAINTEDWHRE LEDLIGHTSTRIPS. AGILITEWHIIE) EXISTINGWALI nr>:vacaoueenoucew<u MIN.(2)WEEPHOLESPERLETTER Q LOWPOINTSWITHLIGHTLEAKCOVERS .L JEWELITETRIMCAP - - - -- Ii 1 /4'DIA.ALLTHREADED - - - -- STU DWITH NUTSAN DWASHERS 1RANSFORMERSREQUIRED FABRICATEDALUMINUM RACEWAY. LISTED'; 120V r. Electrical Diagram AC In OC out Power Supply 12V LN. 12v LED This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. This includes proper grounding and bonding of the sign" 3 of 3