Loading...
HomeMy WebLinkAboutCOLEUS WAY 36695_15-00001178 OITY-O F LADE LSIAOR E BUILDING & SAFETY �= DREAM EXTREME,. 130 South Main Street Lake Elsinore Ca. 92530 PERMIT JOB ADDRESS . . . . . : 36695 COLEUS WAY LT234 TENANT NBR, NAME . . : TRACT 36115 SUMMERFIELD DESCRIPTION OF WORK . : ELECTRICAL OWNER CONTRACTOR PARDEE SOLARCITY CORP. 35050 CANYON HILLS RD 3055 CLEARVIEW WAY LAKE ELSINORE CA 92532 SAN MATEO, CA 94402 - 650-638-1028 LIC EXP 0/00/00 A. P.## . . . . . . 358-372-005 9 SQUARE FOOTAGE 0 OCCUPANCY . . . . GARAGE SQ FT 0 CONSTRUCTION . . . FIRE SPRNKLR . VALUATION . . . 15, 000 ZONE . . . . . . R-1 BUILDING PERMIT QTY UNIT CHG ITEM CHARGE BASE FEE 63 . 00 13 . 00 X 12 . 5000 VALUATION 162 . 50 ELECTRICAL PERMIT QTY UNIT CHG ITEM CHARGE BASE FEE 30 . 00 1 . 00 X 16 . 2500 MISC. WHERE NO OTHER FEE 16 . 25 FEE SUMMARY CHARGES PAID DUE PERMIT FEES BUILDING PERMIT 225 . 50 . 00 225 . 50 ELECTRICAL PERMIT 46 . 25 . 00 46 . 25 OTHER FEES PROF.DEV. FEE 2 TRADES 10 . 00 . 00 10 . 00 PLANNING REVIEW FEE 45 . 10 45 . 10 . 00 PLAN RETENTION FEE ' 1 . 50 . 00 1 . 50 SEISMIC GROUP R 1 . 95 . 00 1 . 95 PLAN CHECK FEES 169 . 13 169 . 13 . 00 TOTAL 499 .43 214 . 23 285 . 20 SPECIAL NOTES & CONDITIONS ROOF MOUNTED SOLAR WITH 15 PANELS, 1 INVERTERS, 3 . 9 KW Qper. COMER COMER2 l ie= CF Drawer: 1 Date: 5t'7v/ 2t) Receipt ,n; 59fi9 201Li 1178 BP BuII.GING PERMIT 1.00ZiS_ C ... 4 Trans n�moer, - 'SC MR 081RD $2710A6 City of Lake Elsinore Please read and initial e Building Safety Division 1.I am Licensed under the provisions of Business and professional Code Section 7000 et.seq.and my license is in full force. Post in conspicuous place 2.I,as owner of the property,or my employees w/wages as their sole compensation will do the w on the job and the structure is not intended or offered for sale. \_ 3.I,as�ow- of--the property,am exclusively contracting with licensed contractors to construct the You must furnish PERMIT NUMBER and the of ject. JOB ADDRESS for each respective inspection: 4.I have a certificate of consent to selfinsure or a certificate of Workers Compensation Insurance Approved plans must be on job or a certified copy thereof at all times: 5.I shall not employ any person in any manner so as to become subject to Workers Compensation Laws in the performance of the work for which this permit is issued. Note:If you should become subject to Workers Compensation after making this certification, Code Approvals Date Inspector you must forthwith comply with such provisions or this permit shall be deemed revoked. ELO 1 Temporary Electric Service PLO 1 Soil Pipe Underground EL02 Electric Conduit Underground BPO1 Footings BP02 Steel Reinforcement BP03 Grout BP04 Slab Grade PLO 1 Underground Water Pipe SSO 1 Rough Septic System SWO1 On Site Sewer BP05 Floor Joists BP06 Floor Sheathing BP07 Roof Framing BP08 Roof Sheathing t t BP09 Shear Wall&Pre-Lath PL03 I Rough Plumbing EL03 IRough Electric Conduit EL04 Rough Electric Wiring EL05 Rough Electric/ T-Bar MEO 1 Rough Mechanical ME02 Ducts,Ventilating PL04 Rough Gas Pipe/Test PL02 Roof Drains BP 10 Framing&Flashing BP 12 Insulation BP13 Drywall Nailing BPI I Lathing&Siding PL99 *Final Plumbing EL99 *Final Electrical ` ME99 *Final Mechanical BP99 *Final Building *Final Signatures are Certificate of Occupancy for Single Family Residence Code Pool&Spa Approvals Date Inspector Z?J4 OTHER DIVISION RELEASES SPO 1 Electric Conduit UG Department Approval required prior to the SP02 UG Gas Piping building be in released by the City SP03 Pool Steel Rein./Forms Date Inspector SP04 Pool Plmb./Pressure Test is _ (1( I Fire SP05 Pre-Gunite Approval EVMWD _ r) SP06 Rough Pool Electric Finance SP07 Pool Fence/Gates/Alarms Engineering SP08 Pre-Plaster Approval j _I TUMF SP99 Final Pool/Spa 4 Planning/Landscape Rq C I T Y,Q F LAKE LSIUO E � � DREAM EXTREME TM 130 South Main Street APPLICATION FOR 71t`1077/77 BUILDING PERMIT ADATLICAT _R CEIVED 5 . VALUATION CALCULATIONS BUILDING ADDRESS 1st FLOOR SF 36695 Coleus TRACT BLOCK/PAGE LOT/PARCEL 2nd FLOOR SF 234 NAME 3rd FLOOR SF O W MAILING PHONE GARAGE SF N ADDRESS same E CITY Lake Elsinore STATE/ZIP STORAGE SF R I hereby affirm that I am licensed under provisions of chapter 9(commencing DECK&BALCONIES SF with section 7000)of division 3 of the business and professions code,and C my license is in full force and effect. OTHER: SF O LICENSE# CITY BUSINESS N AND CLASS 888104/bc10C4raAx# 15, 000 T NAME VALUATION: R Solarcit A MAILING C ADDRESS 3055 Clearview Way FEES T CITY STATE/ZIP PHONE O BUILDING PERMIT 4 R CONTRACTOR'S SIGNATURE uIX1 E PLAN CHECK `� NAME LICENSE# A PLAN REVIEW `�V \ R MAILING C ADDRESS SEISMIC H CITY STATE/ZIP PHONE PLAN RETENTION ❑NEW OCC GRP./ CONST. ❑ADDITION DIVISION: TYPE: ❑ALTERATION NUMBER OF NUMBER OF []OTHER STORIES: BEDROOMS: ❑SINGLE FAMILY ZONE: ❑APARTMENTS ❑I certify that I have read this application and state that the ❑CONDOMINIUM HAZARD YES above information is correct.I agree to comply with all city ❑TOWN HOMES AREA? NO and county ordinances and state laws relating to building ❑COMMERCIAL SPRINKLERS YES construction,and hereby authorize representatives of this ❑INDUSTRIAL REQUIRED? NO city to enter upon the above-mentioned property for insp- []REPAIR ' PROPOSED USE OF BLDG: tion purposes. ❑DEMOLISH PRESENT USE OF BLDG: JOB DESCRIPTION Beverly Miller 5/14/15 residential roof mount Signature of Applicant or Agent Date 15 panels Agent for [jxcontractor ❑ owner 1inverters Agents Name Beverly Miller Agents Address 41568 Eastman Dr. Clper: L``I=EMI='- w I f rli 3rawer: -- Mu rrieta, CA 92562 951-291-8703 ec FIll LilNG fED,11T . Trans number: 11?9424 Trans late: 5i15'/115 Time' 1=1,()p:47 I Version#44.7 QFES. N RA May 12, 2015 C 75189 9Z m X Project/Job #9256409 RE: COVER LETTER Or Project: Summerfield Lot 234 Residence 36695 Coleus Way Lake Elsinore, CA 92532 To Whom It May Concern, Structural review was based on truss calcultaions for Summerfield Lot 234 Phase 2-1 and the design criteria listed below: Design Criteria: -Applicable Codes = 2013 CBC,ASCE 7-10, GITYs F LAKE E LS I fel®R - Risk Category = II-Wind Speed = 110 mph, Exposure Category C B I I I L®I G DIVISION -Ground/Roof Snow Load = 0 psf - MP1: Roof DL = 16 psf, Roof LL = 20 psf cen77 On the above referenced project,the,components of the structural roof framing impacted by the installation of the PV assembly have been reviewed. After this review it has been determined that the existing structure is adequate to withstand the applicable roof dead load, PV assembly load,and live/snow loads indicated in the design criteria above.. The structural roof framing and the new attachments that directly support the gravity loading and wind uplift loading from PV modules have been reviewed and determined to meet or exceed structural strength requirements of the 2013 CBC. Please contact me with any questions or concerns regarding this project. Sincerely, Sri Raghavan, P.E. Professional Engineer T: 888.765.2489 x55470 email: sraghavan@solarcity.com 3055 Clearview Way San Mateo, CA 94402 T(650)638-1028 (888)SOL-CITY F(650)638-1029 solarcity.com A2 ROC;2437/I.CA CS11 3 M61!J4,CO EC 8U t I.CT HIC Ub 12_r8,DC HIC 71101 43C,[,(-,I IIS 71101168.HI CT-297 T0,MA Ii1C.W6 572,MD:.4HIC 12F9;8,NJ 13VI I0d1G0600. OR CC6 180498.f;:G -3 i..C<1 DI_R 27006,WA GCL:S1DLARC"31907 C,2013 Sol❑.Cdy-All ngLts rases -1. 1 I 05.12.2015 • PV System Structural Version#44.7 SolarCityDesign Software PROJECT INFORMATION &TABLE OF CONTENTS Project Name: Summerfield Lot 234 Residence AHJ: Lake Elsinore Job Number: 9256409 Building Code: 2013 CBC Customer Name: Saathoff, Stephaine Based On: IRC 2012/ IBC 2012 Address: 36695 Coleus Way ASCE Code: ASCE 7-10 City/State: Lake Elsinore, CA Risk Category: II Zip Code 92532 Upgrades Req'd? No Latitude/ Longitude: 33.661590 -117.277960 Stamp Req'd? Yes SC Office: Murrieta PV Designer: Todd Baldwin Calculations: Jesus Santiago EOR: Sri Ra havan P.E. Cover Letter 1 Project Information, Table Of Contents, &Vicinity Map 2 Seismic Considerations 3 Structure Analysis (Loading Summary and Member Check) 4 Hardware Design (PV System Assembly) 5 1/2-MILE VICINITY MAP ,��y 71 If t a , T � � c r � �'' � ,r - --��� M��� ��•�*� p, � �r Fri,y 36695 Coleus Way, Lake Elsinore, CA 92532 Latitude: 33.66159, Longitude: -117.27796, Exposure Category: C e SEISMICJCONSIDERATIONS Seismic sign Criteria (per USGS Seismic Design Code ASCE 7-10 Latitude 33.6616 Longitude 117.2780 SRA at Short Period Ss 1.558 USGS SRA at is Period Sl 0.600 USGS Soil Site Gass- D IBC 1613.5.2 Seismic Desi n Category SDC D USGS Seismic•Check.Required(Ss>_ - 0.4 Yes = IBC 1613.1 ALTERATION.LATERAL.DESIGN'_10% EXCEPTION:CHECK-: Weight of Proposed PV System Area Dead Load Weight PV System Weight 266 sf 3 psf 797 Ibs Total Weight of PV System W(Pv) 797 Ibs Weight of Roof'on Existing.Building Sum Area of MPs with PV 504 sf Portion of Roof Weight Area Dead Load Weight Roof 504 sf 16.0 psf 8,061 Ibs Ceiling 504 sf 5.0 psf 2,519 Ibs Interior Walls(Top Half) 359 sf 5.0 psf 1,796 Ibs Exterior Walls oP Hal 359 sf 8.5 psf 3,053 Ibs Net Weight of Roof Under PV W(exist) 15,429 Ibs Check%Increase of Roof Weight/ Seismic Shear Load %.Increase of DCR-of•Lateral 5.2% Force Resistin stem W�PV�/W(e:'st) Increase-Seismic Shear Load <•10%0,.-> [0K] IBC_Sect. .4 ,3404 Note: Seismic base shear is directly proportional to roof weight. LOAD-ITEMIZATION =:•MPl _ PV S stem Load PV Module Weight(psf) 2.5 psf Hardware Assembly Weight(psf) 0.5 psf PV'S stem.Weight(psf.) 3.0 PSIF Roof Dead Load Material Load Roof Category Description MPi Existing Roofing Material Spanish Tile Roof 10.0 psf Re-Roof No Underlayment Roofing Paper 0.5 psf Plywood Sheathing Yes 1.5 psf Board Sheathing None Rafter Size and Spacing 2 x 4 @ 24 in. O.C. 0.7•psf Vaulted Ceiling No Miscellaneous Miscellaneous Items 3.3 psf Total Roof Dead Load 16 psf(MPl) 16.0' sf Reduced Roof.LL Non-PV Areas Value ASCE 7-10 Roof Live Load Lo 20.0 psf Table 4-1 Member Tributary Area At < 200 sf Roof Slope 4/12 Tributary Area Reduction Rl 1 Section 4.8 Sloped Roof Reduction R2 1 Section 4.8 Reduced Roof Live Load Lr L,= L.(RI)(R2) Equation 4.8-1 Reduced Roof Live Load '`Lr:. .' 20 psf,(MPi) : 20.0. sf _- ti Simpson Strong-Tie Truss: MP1-K2 Project Name: 9256409 = Component SolutionsTM Date: 5/12/2015 12:53:53 PM p Page: 1 of 1 Tdiss ' Version:5.15.50[Build 7] Span Pitch Qty OHL OHR CANT L CANT R PLYS Spacing WGT/PLY 29-4-8 4/12 1 I-2-0 1-2-0 0-0-0 0-0-0 1 24in 1 l llbs 31-8-8 1-2-0 7-10-0 6-10-4 621-6-8-10.4 7-10-0 1-2-0 7-10-0 14-8-4 29-4-8 5x5- 3 12 12 4� �4 3x4/ 3x4\ _ 2 4 N� A d 3x7- 3x6- } 1 5 10 11 9 8 7 6 1 x4 J 4x4- 1 x4 l 3x7- 0-0-0 0-0-0 7-10-0 6-10-4 6-10-4 7-10-0 7-10-0 14-8-4 21-6-8 29-4-8 Loading General CSI Summary Deflection LJ (loc) Allowed (pso Bldg Code: CBC 20131 TC: 0.93(1-2) Vat TL: 0.5 in L/702 (9-1) L/180 20 TPI I-2007 BC: 0.69(9-1) Vert LL: <0.25 in L1240 16(ralaa) Rep Mbr Increase: Yes Web: 0.99(4-8) He.TL: 0.15 in 5 0 D.O.L.: 125% Cnxp Factor.Kcr=1.5 BCDL: 8 Plate Offsets(Jnt:X,Y,Ang): (1:4-14,2-1,0.) (2:1-12.3-2,18.) (3:0-03-11.0.) (4:1-12.3-2,18.) (5:4-14,2-1,0.) (6:0-0,3-8,90.) (7:0-0,2-0,0.) (8:0-0.3-8,0.) (9:0-0,3-8,90.) Reaction Summary JT Tvpc Bag Combo Bag Width Material Rqd Brg Width Max React Max Gmv Uplift Max MWFRS Uplift Max C&C Uplift Max UpIiR Max Horiz 1 Pin(Wall) l 3.5 in Douglas-Fir-Iamb 1.64 in 1,541 Ibs - - - - 0 Ibs 5 H Roll(Wall) 1 3.5 in Douglas-Fir-Inch 1.54 in 1,448 ubs - - - - 0 Ibs Material Summary Bracing Summary TC DFL 91 B 2x4 TC Bracing Sheathed or Pudins at 2-3-0.Pudin design by Others. BC DFL#I B 2x4 BC Bracing: Sheathed or Pudins at 10-".Purimdesign by Others. Webs DFLSumdard 2x4 Loads Summary 1)Minimum storage attic loading in accordance with IBC Table 1607.1 has not been applied 2)In accordance with rBC Table 1607.1,minimum BCLL's do not apply. Load Case D1:Std Dead Load Distributed Loads Member Incation 1 Location 2 Direction Spread Stan Load End Load Taib Width Top Clad 2-0-0 11-10-0 Down Rals 9 psf 9 psf 24 in Member Forces Summary Table indicates:Member m,max CSL max axial force.(max compr force ifdilleacnt from max axial force) TC IO-t 0.079 271bs 2-3 0.511 -2,370 lbs 4-5 0.775 -3.379 lbs' 1-2 0.926 -3.60316s 3-1 0.412 -2,349 lbs 5-II 0.079 2716s BC 56 0.620 3,1341bs 8-9 0.532 333716s 6.8 0.498 3,I341bs 9-1 0.688 3:3371bs Webs 2-9 0.080 1601bs 3-8 0.378 930 Ibs 4-60.076 153 lbs 2-8 0.330 -1.271 Ibs 4-8 0.982 -1.0531bs Notes: "hen this truss has bcen chosen for quality assurance inspection,the Plate Placement Method per TPl I-2002/A3.2 shall be used.Cq=1.17. 2) ®Indicates continuous lateral restraint(CLR)inquired at the location(s)shown.Rotas of CLR must be adequately diagonally braced.see D-W EBCLRBRACE For altematires to CLRs and diagonal bracing see D-WEBRERJFORCE. 3)Bearingmaterial shown in the above table has onlybeen claccU forresistance perpendicularto grain,and does not indicate adequaeyofmaterial forotherdesign considerations. i NOTICE Acopyorthis design shall be furnished to the erection contractor.The design of this individual truss is based on design criteria and mquirements supplied by dneTmss Manufacturarand relics upon the accumcy Simpson Strong-Tie Company and completeness of the information set forth by the Building Designer.A scal on this darning indicates acceptance of pmfessional enginoering responsibility solely for the truss component design shown.Sec the cover page and the"Important Information&General Noles"page for additional information.All connector plates shall be manufactured by Simpson Strong-Tie Company.Inc in accordance with ESR-2762.All connector plates are 20 gauge,unless the specified plate sire is followed by a'A 8"which indicates an 18 gauge plate,or"S#18".which indicates a high tension 18 pule plate. i CALCULATIOU OF DESIGN-WIND-LOADS:= MP1 -: :. Mountina Plane.Information Roofing Material Spanish Tile Roof PV System Type SolarCity SleekMountTM Spanning Vents No Standoff Attachment Hardware SM Tile Roof Slope 180 Rafter Spacing 24"O.C. Framing Type/Direction Y-Y Rafters Purlin Spacing X-X Purlins Only NA Tile Reveal Tile Roofs Only 13" Tile Attachment System Tile Roofs Only SM Tile Standing Seam/Trap Seam/Trap Spacing SM Seam Only NA Wind Desi n Criteria Wind Design Code ASCE 7-10 Wind Design Method Partially/Fully Enclosed Method Basic Wind Speed V 110 moh Fig. 26.5-1A Exposure Category C Section 26.7 Roof Style Gable Roof Fig.30.4-2A/B/C-5A/B Mean Roof Height h 25 ft Section 26.2 Wind'Pressure Calculation Coefficients _ Wind Pressure Exposure KZ 0.95 Table 30.3-1 Topographic Factor KA 1.00 Section 26.8 Wind Directionality Factor Kd 0.85 Section 26.6-1 Importance Factor I NA Velocity Pressure qh qh = 0.00256(Kz)(Kzt)(Kd)(V^2) Equation 30.3-1 24.9 psf . y Wind Pressure Ext. Pressure Coefficient U GC -0.88 Fig.30.4-2A/B/C-5A/B Ext. Pressure Coefficient Down G Down 0.45 Fig.30.4-2A/B/C-5A/B Design Wind Pressure p p =qh(GC ) Equation 30.4-1 Wind-Pressure U P;, 21.8'Ps Wind Wind Pressure Down 16.0 psf' ALLOWABLE STANDOFF SPACINGS X-Direction Y-Direction Max Allowable Standoff Spacing Landscape 72" 39" Max Allowable Cantilever Landscape 24" NA Standoff Configuration Landscape Not-Staggered Max Standoff Tributary Area Trib 19 sf PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff T-actual -221 Ibs Uplift Capacity of Standoff T-allow 446 Ibs Standoff Demand Ca ac' DCR 49.6% X-Direction Y-Direction Max Allowable Standoff Spacing Portrait 48" 65" Max Allowable Cantilever Portrait 19" NA Standoff Configuration Portrait Not-Staggered Max Standoff Tributary Area Trib 22 sf -;PV Assembly Dead Load W-PV 3.0 psf !Net Wind Uplift at Standoff T actual -248 Ibs Uplift Capacity of Standoff T-allow 446 Ibs Standoff Demand/Capacity DCR 55.5% ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID—INTERTIED VIA A ALL EXPOSED CONDUIT WILL BE PAINTED TO :ty AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. Division A proval MATCH HOUSE. r� °1 DG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. �anrlirq )NC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING ALL LABELS WILL BE MADE FROM REFLECTIVE U�: DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN MATERIAL. Approved BY: EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING SMOKE AND CARBON MONOXIDE DETECTORS TO BE EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, INSTALLED PER CRC R314 AND R315. Date: — I FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED HAZARDS PER ART. 690.17. A LADDER SHALL BE SET UP AND READY FOR THE GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE INSPECTION. CITY O F LAKE E LS I N O R GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. � �; ; L.D i N G DIVISION 1 CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC t-.Y.. f )-7 LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). PEF­ 0 ,i MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE 0'%fE_` D PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING POI POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. ' S STAINLESS STEEL `C STANDARD TESTING CONDITIONS TYPICAL ut,S UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT �. .� PVl COVER SHEET 3R NEMA 3R, RAINTIGHT " �' q PV2 SITE PLAN r r. 1 f �t ,. PV3 STRUCTURAL VIEWS PV4 UPLIFT CALCULATIONS LICENSE GENERAL NOTES /' , PV5 THREE LINE DIAGRAM "� * Cutsheets Attached 1. ALL WORK TO BE DONE TO THE 2013 ~ _ X CA C 108104 CALIFORNIA BUILDING CODE AND THE 2013 ,,� CALIFORNIA RESIDENTIAL CODE. ,.,Ben Liu 2. ALL ELECTRICAL WORK SHALL COMPLY WITH f { THE 2011 NATIONAL ELECTRIC CODE AS AMENDED BY THE 2013 CALIFORNIA ELECTRIC CODE. �_ � �-,. _ • ; �1 � ., :k MODULE GROUNDING METHOD: ZEP SOLAR AHJ: Lake Elsinore : REV BY DATE COMMENTS •_ „_ `� � �" r _ €1A_r ti� i REV A NAME DATE COMMENTS UTILITY: Southern California Edison 1-19DENTIAL - THE INFORMATION HEREIN JOB NUMBER: PREMISE OMNER: DESCRIPTION: DESIGN: JB-9256409 00 TAINED SHALL NOT BE USED FOR THE SAATHOFF, STEPHAINE Summerfleld Lot 234 Phase 2-1 Todd Baldwin �. `.• • .FIT OF ANYONE EXCEPT IN MOLE INC., MOUNTING SYSTEM: 36695 COLEUS WAY 3.9 KW PV ARRAY -.IsolarCity "UK SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP ZS Tile STile PART TO OTHERS OUTSIDE THE RECIPIENT'S MODULES: LAKE ELSINORE CA 92532 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (15) KYOCERA # KU2606XPA 3055 Clearvie. way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV: DATE: T:(650) 638 SonMate CA 9440638-t029 PERMISSION OF SOLARCITY INC 5622337185 PV 1 5 11 2015 866 ABB PV-3.6—OUTD—S—US—Z—A COVER SHEET / / ( )—SOL—CITY(765-2489) Mwwsolarcity.com Berg Liu PITCH: 18 ARRAY PITCH: 18 �- MP1 AZIMUTH: 246 ARRAY AZIMUTH: 246 MATERIAL: Spanish Tile STORY: 2 Stories STAMPED & 516NED FOR STRUCTURAL ONLY mpi — — — — - - 3'FSB- - - - - - OFESS�oN - - G) T I �T x C 75189 9z m WI _ X LEGEND I � C/VIL �\P (E) UTILITY METER & WARNING LABEL OF CAL1F Ins INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS I © DC DISCONNECT & WARNING LABELS I © AC DISCONNECT & WARNING LABELS I DC JUNCTION/COMBINER BOX & LABELS � AC DISTRIBUTION PANEL & LABELS —�_ — L — — J — Lc LOAD CENTER & WARNING LABELS nv ; O ODEDICATED PV SYSTEM METER Front Of House STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR ——— CONDUIT RUN ON INTERIOR (E) DRIVEWAY GATE/FENCE O HEAT PRODUCING VENTS ARE RED r,_ ik '1 INTERIOR EQUIPMENT IS DASHED L_/J 36695 Coleus Way SITE PLAN TOTAL ARRAY AREA (SF): 271 = TOTAL ROOF AREA (SF): 1659 Scale: 1/8" = 1' TOTAL ARRAY AREA IS a 16 0 1' 8' 16' 3 PERCENT OF TOTAL ROOF AREA PREMISE OWNER: DESCRIPTION: DESIGN: ""'IFIDENTIAL THE INFORMATION HEREIN �NUMBER: JB-9256409 00 SAATHOFF STEPHAINE Todd Baldwin \\_` tTAINED SHALL NOT BE USED FOR THE ■ IEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: ummerfield Lot 234 Phase 2—� SolarC�ty NOR SHALL IT BE DISCLOSED IN WHOLE OR IN 36695 COLEUS WAY PART TO OTHERS OUTSIDE THE RECIPIENT'S ZEP ZS Tile STile 3.9 KW PV ARRAY /�1� ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES LAKE ELSINORE, CA 92532 THE SALE AND USE OF THE RESPECTIVE (15) KYOCERA # KU2606XPA 3055 aearAe■ Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE: San Mateo, CA 94402 PERMISSION OF SOLARCITY INC. INVERTER: 5622337�85 )-SOL) CITY(7 5 F:9) w 638—I029 ABB PVI-3.6—OUTD—S—US—Z—A L SITE PLAN PV 2 5/11/2015 (888)—SOL—CITY -2489) .W..gdarcilY.cam Ben Li u o \ l' Si STAMPED & SIGNED FOR STRUCTURAL ONLY 71-519 ,_ » ROFESS�O V— � ) LBW \�PRI �Cti q�F E A SIDE VIEW OF MPI NTS C75189 'z m I MP1 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES '9j� ' CNIL �P LANDSCAPE 72" 24" OF CALIFO%� PORTRAIT 48" 19" TOP CHORD 2X4 @ 24" OC ROOF AZI 246 PITCH 18 STORIES: 2 ARRAY AZI 246 PITCH 0 BOT CHORD 2X4 @24" OC S-Tile (Cement) INSTALLATION ORDER " DIA THREADED STUD REMOVE TILE, LOCATE & MARK & NUT (1) BASE & DRILL PILOT HOLES.RAFTER LOCATION.PLACE STANDOFF ZEP LEVELING FOOT _______ _______ ____________ ZEP TOP ARM 2) CLEAN PAPER AROUND PILOT HOLE. ZEP ANTI-ROTATION PLATE (6) M10 BOLTS SEAL PILOT HOLES AND BOTTOM OF MOUNTING BASE �5) (3) STANDOFF SEALANT. THPOLYURETHANE (E) TILE (E) ROOF DECKING (E) RAFTER (4) Lj u (2) 4) LAG STANDOFF BASE INTO RAFTER. " DIA STAINLESS (3) (5) PLACE FLASHING AND ATTACH STEEL LAG BOLT (2-j" SEALING SPACER WITH SINGLE BOLT. EMBED, MIN) PLACE'ZEP BAR. THEN INSTALL (6) LEVELING FOOT WITH BOLT & WASHER. STANDOFF _ - , JB- 'FIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: PREMISE OWNER: DESCRIPTION: DESIGN: ' ''-�TAINED SHALL NOT BE USED FOR THE 9256409 0�WHOLESAATHOFF STEPHAINE * Todd Baldwin ".FIT OF ANYONE EXCEPT SOLARCITYINC., MOUNTING SYSTEM: ' ��SolarCity. �.NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP ZS Tile STile 36695 COLEUS WAY 3.9 KW PV ARRAY ►�, PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES LAKE ELSINORE, CA 92532 THE SALE AND USE OF THE RESPECTIVE (15) KYOCERA # KU2606XPA 1 1 3055 Clearview Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN q p PAGE NAME SHEET- REV: DATE: San Mateo, CA 94402 PERMISSION OF SOLARCITY INC. INVERTER. 5622337185 H5 T:(650)638-1028 F:(650) 638-1029 ABB PVI-3.6-OUTD-S-US-Z-A STRUCTURAL VIEWS PV 3 5/11/2015 (888)-SOL—CITY(765-2489) www.solarcity.com Ben Li u • UPLIFT CALCULATIONS SEE SEPARATE PACKET FOR STRUCTURAL. CALCULATIONS. "i,FlDENIIAL THE INFORMATION HEREIN NUMBER: J B-9256409 00 PREMISE OWNER: DESCRIPTION: DESIGN: \\\ EnT O SHALL NOT E USED FOR THE SAATHOFF, STEPHAINE * Todd Baldwin solarCity. �.'EFlT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM:NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP ZS Tile STile 36695 COLEUS WAY 3.9 KW PV ARRAY 'i� PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES LAKE -ELSINORE, CA 92532 THE SALE AND USE OF THE RESPECTIVE (15) KYOCERA # KU2606XPA y 3055 gearview Wo SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET: REV: DATE: Son Mateo, CA 94402 SOLARCITY INC. INVERTER: 56223371 85 T:(650) 638-1028 F:(650)638-1029 PERMISSION OF SOLAR ABB PSI-3.6-0UTD—S—US—Z—A UPLIFT CALCULATIONS PV 4 5/11/2015 (686)-soL-CITY(765-2489) www.solarcity.com GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND N 8 GEC TO E UFER AT PANEL Panel Number: Inv 1: DC Ungrounded ( ) # LABEL: A ( ) # CA # 888104 ( ) # � ) Meter Number: INV 1 — 1 ABB PVT-3.6-OUTD-S-US, 240V, — 15 KPVCModule;K260W6232.9W PTC, 40MM, Blk Frame, H4, ZEP, 1000V, w Ba kb r C-10 'WITH IRREVERSIBLE CRIMP FCI Inverter; Zigbee 3600W, 240V, 96% / Underground Service Entrance INV 2 Voc:-38.3 Vpmax: 31 Ben Liu INV 3 1 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER l E 200A MAIN SERVICE PANEL E 20OA/2P MAIN CIRCUIT BREAKER ADJUST MIN. ACTIVATION VOLTAGES! SolarCity CUTLER-HAMMER Inverter 1 IND 4 A 4ED 20OA/2P Disconnect 5 ABBC+ Vstart= 120V PVT-3.6-OUTD-S-US-Z-A ----- MP 1� 1x8-(E) LOADS B EGC 24aV ———————— ———————————— ———————— — ———— � L1 L2 DC+ I N 20A/2P 2c I 3 Vstart= 120V 3 13) q GECNDG jQDc+ MP 1: 1x7 GND __ EGC— ---------tl)Conduit ------------ --- ---- — -----------------j I I Kit; 3/4" EMT N I EGC/GEC - --- — Z Z U' --- GEC --� TO 120/240V SINGLE PHASE I UTILITY SERVICE I I I I CONNECT TO THE EXISTING GEC OR BY IRREVERSIBLE CRIMP TO EXISTING GROUND WIRE. Voc* = MAX VOC AT MIN TEMP POI (1)SQUARE D HQM220 PV BACKFEED BREAKER R —(1)CUTLER-HAMMER #DG222URB /� (1)SolarCit 4 STRING JUNCTION BOX Breaker, 2'OA 2P, 2 Spaces �+ Disconnect; 60A, 240Vac, Non-Fusible, NEMA 3R AC / 2x2 S.&A 4 STRING JUNCTION GROUNDED DC —(1)CUTLER-�IAMMER N DG10ON6 Ground Neutral it; 60-1100A, General Duty(DG) I - ' - - -- ----- - -- --- ---- -- -- - -- - - -- ____(1 --, TH----WN-2—,---Black-- - -- - - - - --- � )AWG #10 (1)AWG #10, THWN-2, Black Voc* =303.81 VDC Isc =9.09 ADC (2)AWG #10, PV Wire, 60OV, Black Voc* =347.21 VDC Isc =9.09 ADC O IoF (1)AWG #10, THWN-2, Red O � (1)AWG #10, THWN-2, Red Vmp =217 VDC Imp=8.39 ADC ', O � (1)AWG #10, Solid Bare Capper EGC Vmp =248 VDC Imp=8.39 ADC j LL�-LL(1)AWG #10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=16 AAC (1)AWG #10, THWN-2, Green EGC- -(1)AWG Q8, 1HWN-2, Green EGC/GEC—(1)Conduit Kit; 3/4' EMT (1)AWG #10, THWN-2, Black Voc* =347.21 VDC Isc =9.09 ADC (2)AWG #10, PV Wire, 60OV, Black Voc* =303.81 VDC Isc =9.09 ADC I ® (1)AWG #10, THWN-2, Red Vmp =248 VDC Imp=8.39 ADC (1)AWG #10, Solid Bare Copper EGC Vmp =217 VDC Imp=8.39 ADC (1)AWG #10. THWN-2, Green EGC O I � I ^^MFlDENTIAL- THE INFORMATION HEREIN JOB NUMBER: PREMISE OWNER: DESCRIPTION: DESIGN: / 'TAINED SHALL NOT BE USED FOR THE J B-9256409 �0 SAATHOFF STEPHAINE Todd Baldwin • EFlT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: Summerfield Lot 234 Phase 2-1 SolarCity-riuR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP ZS Tile STile 36695 COLEUS WAY 3.9 KW PV ARRAY ��� PART IZ OTHERS OUTSIDE THE RECIPIENT'S MODULES LAKE ELSINORE, CA 92532 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (15) KYOCERA # KU2606XPA 3055 Clearview Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET: REV: DATE San Mateo, CA 94402 PERMISSION OF SOLARCITY INC. INVERTER. 5622337185 T:(650) 638-1028 F:(650)638-1029 ABB # PVT-3.6-OUTD-S-US-Z-A I THREE LINE DIAGRAM PV 5 5/11/2015 (888)-sOL-CITY(765-2489)www.solarcity.com CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: - Address: 36695 Coleus Way AC DISCONNECT � I UTILITY I SERVICE L------------J INVERTER AND DC DISCONNECT --------------- ------- SOLAR- PHOTOVOLTAIC----ARRAYS) -PHOTOVOLTAIC BACK-FED CIRCUIT BREAKER IN MAIN ELECTRICAL PANEL IS AN A/C DISCONNECT PER NEC 690.17 OPERATING VOLTAGE = 240V JB-9256409-00 "^'1FlDENIIAL THE INFORMATION HEREIN JOB NUMBER: J B PREMISE OWNER: DESCRIPTION: DESIGN:-9256409 OO � �\,�a ITAINED SHALL NOT BE UD FOR THE SAATHOFF, STEPHAINE Todd Baldwin Summerfield Lot 234 Phase 2-1 -- SolarCity. NU_ EFIT OF N MALL IT BE DISCLOSED EXCEPT N WHOLE OR IN M�'"¶"�SYSTEM:Tile 36695 COLEUS WAY 3.9 KW PV ARRAY 'i; PART TO OTHERS OUTSIDE THE RECIPIENT'S ZEP ZS Tile STile ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES LAKE ELSINORE, CA 92532 THE SALE AND USE OF THE RESPECTIVE (15) KYOCERA # KU2606XPA 3055 gearview Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME SHEET: REV: DATE San Mateo, CA 94402 PERMISSION OF SOLARCITY INC. 5622337185 PV 6. 5 11 201 )(650)638(1028 F:(650)638-1029 ABB PVT-3.6—OUTD—S—US—Z—A SITE PLAN PLACARD / / 5 (888—SOL—CITY 765-2489)www.solarcity.com WARNING;PHOTOVOLTAIC POWER SOURCE "' • • '' ' ' �PV SYSTEM WARNING ••- DISCONNECT FOR ELECTRIC SHOCK HAZARD - • UTILITY OPERATION •. THE DC CONDUCTORS OF THIS •- • • PHOTOVOLTAIC SYSTEM ARE : PHOTOVOLTAIC DC UNGROUND.EDAND DISCONNECT ••_ MAYBE ENERGIZED WARNING ELECTRIC SHOCK HAZARD • •- • - • DO NOT TOUCH TERMINALS ' MAXIMUM POWER _A TERMINALS ON BOTH LINE AND POINT CURRENT(Imp) ._ _ LOAD SIDES MAY BE ENERGIZED •' IN THE OPEN POSITION POINT VOLTAGE Vm MAXIMUM E(Vmp)_V. •• MAXIMUM SYSTEM V VOLTAGE(Voc)_ SHORT-CIRCUIT CURRENT(Isc)_A WARNING -• INVERTER.OUTPUT CONNECTION ' "•- • • DO NOT RELOCATE WARNING THIS O DEVICE NT DEVICVICE. ELECTRICAL SHOCK HAZARD - DO NOT TOUCH TERMINALS •' 'TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION _ DC VOLTAGE IS PHOTOVOLTAIC POINT OF - ALWAYS PRESENT WHEN INTERCONNECTION _ SOLAR MODULES ARE WARNING:ELECTRIC SHOCK - EXPOSED TO'SUNLIGHT HAZARD. DO NOT TOUCH •' •' TERMINALS.TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY.BE ENERGIZED IN THE OPEN POSITION. FOR SERVICE • • DE-ENERGIZE BOTH SOURCE WARNING AND MAIN BREAKER. PV POWER SOURCE. MAXIMUM AC ELECTRIC SHOCK HAZARD •• _ A, IF AGROUND FAULT IS INDICATED • OPERATING CURRENT NORMALLY GROUNDED MA'XI'MUM AC V CONDUCTORS MAY BE OPERATING VOLTAGE _ UNGROUNDED AND ENERGIZED ••- _• - • CAUTION '• _ _ PHOTOVOLTAIC AC �_ PHOTOVOLTAIC SYSTEM DISCONNECT - •' CIRCUIT ISBACKFED ••� •' • • MAXIMUM AC _ A - CAUTION -• • OPERATING CURRENT -- ••- DUAL POWER SOURCE '- ••- •"• _ MAXIMUM AC SECOND SOURCE IS - OPERATING VOLTAGE _ V '• PHOTOVOLTAIC SYSTEM -• -• • • • ''^SolarCit Z Solar Next-Level PV Mounting Technology '�iSolarCit Z Solar Next-Level PV Mounting Technology Y P 9 9Y Y p 9 9Y Zep System Components for tile roofs using replacement tiles P ILevel ng Fa Ti attaches to Top I Arm smd I TW Arm attaches to �`� _ _ ? Ann-RORtIm Plate.Tile .� .. Flashing,arM MWnnng '} I Bate T Replacement S-Tile TppAm _-_- 1 Part No.850-1435 I :md - ''� Listed to ILL 2703 : Anti RoW 9Plate caches to Tile Flasnmg _,., ana Mw�na Base I I, i� Replacement W-Tile Part No.850-1437 Listed to UL 2703 Mnuaunq Base `I "� `- � attaches!Hough root sheaBung ora er Rane Replacement Flat Tile - I Part No.850-1436 Listed to UL 2703 I I I I I I Description W PV mounting solution for concrete tile roofs °COMP at�e Works with all Zep Compatible Modules • Zep System UL 1703 Class A Fire Rating for Type 1 and Type 2 modules ` Auto bonding UL-listed hardware creates structual and electrical bond U� LISTED Tile Roof Attachment Kit Interlock Leveling Foot Part No.850-1434 Part No.850-1388 Part No.850-1397 Specifications Listed to UL 2582 Listed to UL 2703 Listed to UL 2703 ETA : Designed for pitched roofs Installs in portrait and landscape orientations • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 • Wind tunnel report to ASCE 7-05 and 7-10 standards • Zep System grounding products are UL listed to UL 2703 and ETL listed to UL 467 • Zep System bonding products are UL listed to UL 2703 Engineered for spans up to 72"and cantilevers up to 24" Zep wire management products listed to UL 1565 for wire positioning devices Ground Zep Array Skirt,Grip,End Caps DC Wire Clip Attachment method UL listed to UL 2582 for Wind Driven Rain Part No.850-1172 Part Nos.500-0113, Part No.850-1448 Listed to UL 2703 and 850-1421,850-1460, Listed UL 1565 ETL listed to UL 467 850-1467 zepsolar.com zepsolar.com Listed to UL 2703 This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely each product.The end-user documentation shipped with Zap Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely responsible for verifying the suitability of Zep Solar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. responsible for verifying the suitability of Zep Solar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. 12 31 14 ZS for Replacement Tile Applications Cutsheet Rev 02.pdf Page: 1 of 2 12 31 14 ZS for Replacement Tile Applications Cutsheet Rev 02.pdf Page: 2 of 2 Solar inverters Additional highlights: -------- - RS-485 communication interface stringABB inverters (for connection to laptop or data logger). PV1-3.0/3.6/3.8/4.2-TL-0UTD - Integrated Arc Fault Detection and Au Interruption(-A Version). to / I1 l x ( ( Technical data and types Type code PVI-3.0-OUTD-US PVI-3.6-OUTD-US PVI-3.8-OUTD-US PVI-4.2-OUTD-US ABC Mechanical specifications - >•-r, Nominal output power 3000W 360OW 3300 380OW 420OW Maximum output power wattage 3000 3300' 3300' ! 3600 ! 4000' 4000' 3300 4200' 42001 4200 4600' 4600' W W W W W W W W W W W W Rated grid AC voltage 208V 240V 277V 208V 240V 277V 208V 240V 277V 208V 240V 277V a Input side(DC) Number of independent MPPT channels 2 2 2 2 Maximum usable power for each channel 2000W 3000W 3000W 3000W Absolute maximum voltage(Vmax) 600V Start-up voltage(Vstart) 11 200V(adj.120-35OV) Full power MPPT voltage range 160-530V 120-530V 140-530V 140-530V e _ Operating MPPT voltage range 0.7 x Vstart-580V(>-90V) e Maximum current(ldcmax)for both MPPT in 20A 32A 32A 32A parallel Maximum usable current per channel 10A 16A 16A 16A Maximum short circuit current limit per 12 5A 20.OA 20.OA 20.OA channel Number of wire landing terminals per channel 2 pairs Array wiring termination Terminal block,pressure clamp AWG10-AWG4 Output side(AC) Grid connection type 1Split- 1 / 1 / Split- 1 / 1 / Split- 1 / 1Split- 1 / _ 2W ;_0/3W 2W _ 2W O/3W 2W 2W 0/3W 2W 2W 0/3W 2W 183- 211 244 183- 211-..... 244 183 211- 244- 183- 211- 244- •— Adjustable voltage range(Vmin-Vmax)(V 228V 264V 304V 228V 264V 304V 228V 264V 304V 228V 264V : 304V Grid frequency 60Hz Adjustable grid frequency range 57-60.51-1z Maximum current(Ian,—) 14.5 ' 14.5 12.0 17.2 16.0 16.0 16.0 16.0 16.0 20.0 20.0 20.0 A,Ms A_. Arms A_ Aays_ : Aams Anms A„_ Awns _A,Ms_ Aams A.. Power factor >6.995 Total harmonic distortion at rated power <2% This family of single-phase string The high-speed MPPT offers real- Highlights: Grid wiring termination type Terminal block Pressure clamp AWG10-AWG4 inverters complements the typical time power tracking and improved - Single phase and split phase output Input protection devices Reverse polarity protection Yes number of rooftop solar panels energy harvesting. grid connection. Over-voltage protection type Varistor,2 for each channel enabling home-owners to get the most The flat efficiency curve ensures high - Wide input range for increased PV array ground fault detection Pre start-up Riso and Dynamic GFDI(requires floating arrays) efficient energy harvesting for the size efficiency at all output levels allowing stringing flexibility. Output protection devices of the property. a consistent and stable performance - The high speed and precise MPPT Anti-voltding protection Meets UL T74t/IEEE15a7 requirements Overrage protection type Vanstor,2(L-Lz/L-G) across the entire input voltage and algorithm offers real time power Maximum AC OCPD Rating 20A 20A 15A 25A 20A 20A 20A 20A 20A 25A 25A 25A This inverter offers a dual input output power range. tracking and improved energy Efficiency section that processes two strings The transformerless operation gives the harvesting. Maximum efficiency 96.9% 97% 97% 97% CEC efficiency 96% with independent Multiple Power Point highest efficiency of up to 97.0%. - Outdoor NEMA 4X rated enclosure Operating performance Tracking(MPPT). The wide input voltage range makes for unrestricted use under any Night time consumption _ <0.6Wo„, This is especially useful for rooftop the inverter suitable to low power environmental conditions. Stand-by consumption <8w. Communication installations with two different installations with reduced string size. - Integrated DC disconnect switch User-interface 16 characters x 2 lines LCD display orientations from two sub-arrays This rugged outdoor inverter has been in compliance with international Remote monitoring(1 xRS485 incl.) VSN700 Data Logger(opt.) oriented in different directions.(For designed to be a completely sealed Standards(-S Version). Environmental Ambient air operating temperature range 13'F to+140'F with derating above 122'F(50'C) example: East and West) unit able to withstand the harshest Ambient air storage temperature range -40'F to+176'F(-40'C to+80'C) The dual input sections with environmental conditions. Relative humidity o-1 ob%PH condensing independent MPPT enable a more Acoustic noise emission level <50 db(A)61 m Maximum operating altitutde without derating 6560 It(2000 m) optimal energy harvesting condition. Power-and productivity AuB 1 capability enabled at nominal AC voltage and with sufficient DC power available. for a better world' 2 AB8 Solar Inverters I Product flyer for PVI-3.0/3.6/3.8/4.2-1-L-OUTD KU-60 1000V Series ELECTRICAL SPECIFICATIONS MODULE CHARACTERISTICS ,' l(YOCERa K U 6 0 10 0 0 V Z SeriesStandard � • •Test Conditions Cells per module: 60(6 x 10) ,� tOO " " Dimensions: 65.43ini38.98ini1.57in KU255-6XPA KU260-6XPA 60 , length/width/height (1662mmi990mmi40mm) Weight 47.41bs(21.5kg) CUTTING EDGE TECHNOLOGY --- - --- Pma„ 255 260 w As a pioneer with four decades of experience in the v,v 30.8 31.0 v PACKAGING SPECIFICATIONS development of photovoltaic systems, Kyocera drives the MENNEN market as a leading provider of PV products.We ImR 8.28 839 A Modules per pallet: 20 demonstrate our Kaizen philosophy,or commitment toMENNEN vo� 38.0 38.3 v Pallets per53'container. 36 continuous improvement,by setting the industry standard Pallet box dimensions: 66ini40ini43in in the innovation of best-in-class solar energy equipment. I, 8.83 9.09 A Length/width height (1 675mml 1005mm 11 055mm) MEMNON Pt.le-, +5/-0 +5/-0 % Pallet box weight: 1060lbs(480kg) QUALITY BUILT IN Nominal Operating Cell Temperature Conditions(NOCT) •UV-stabilized, anodized aluminum frame in black NOCT=800 WIM`irradiance,20,1Cambient S, lanl 0.03" •Supported by major mounting structure manufacturers MENNEN MEMNONT_ 45 45 °C I I POTTED •Easily accessible grounding points on all four corners Pm 183 187 w = � BOXoP1 i for fast installation MENNENv p z7 7 27,9 v •Proven junction box technology with 12 AWG PV wire ec R works with transformerless inverters I�v 6.61 6.71 A LABEL STABILIZER BAR •Amphenol H4-UTX locking plug-in connectors V. 34.8 35.1 v provide safe,quick connections MENNEN I 7.15 7.36 A � a PROVEN RELIABILITY PTc 228.3 232.9 w •Kyocera modules confirmed by the Desert Knowledge Tempel ature CoefficientsSTABLIZERBAR Australia Solar Centre to have the highest average MENNEN output of any crystalline module Pm -0.45 -0.45 %J°C 1.10-(2e•e) •First module manufacturer in the world to pass long- v� o.as o.a8 %�°c term sequential testing performed by TUV Rheinland MEMO 0 •Only module manufacturer to achieve the rank of I, 0.02 0.02 %J°C "Performance Leader" in all six categories of GTM _ _ _ __ -_ va -0.36 -0.36 %'°c 08.98"(990nm) Research's 2014 PV Module Reliability Scorecard Ix 0.06 0.06 %/°C 0 CERTIFICATIONS operating Temp -40 to+90 -40 to+90 °C D Noce Slotted Nowting Hole 0.16' (Mn) 0.35'a0.47" (9megl2w) •UL1703 Certified and Registered,UL Module Fire System Design Performance:Type 2,CEC FRAME CROSS SECTION DIAGRAM •NEC 2008 Compliant,IEC 61215/61730,and ISO 14001 series Fuse mating 15 A � Maximum DC System voltage(UL) 1000 V CpMPATj� US = E Hailstone Impact in(25mm)@ 51 mp(23m/s) OOMPPj� �.S -as LOX6/SHNT SIDE STABILIZER BAR NEC 2008 COMPLIANT wa UL 1703 U51ED 062614 OUR VALUED PARTNER - i ZeL. ZepSolar ZS COMP I GROUNDING AND BONDING p Z m TM Grounding and Bonding Interlock Interlock Zep S Co p l g g Koyy irte This document describes the mechanics of how the electrical bonding is accomplished between the UL Listed hardware components used in Zep Solar's ZS Comp mounting solution for composition shingle roofs. Part No.850-1388 Zep Compatible"systems do not require running copper conductors to each module.The act of physically UL Listed to UL2703 installing each component simultaneously establishes an electrical bond,as described in the following XZT.ngue side pages. -- - Key Side Bonding — ass ,a;;rt ._..,• - -., _ _ Cutting"tooth" F Side view Interlock J Module Ground Zep Interlock(Key side shown) Key side in closed position 't Bondi ngtocations - Zep Compatible module Cutting"tooth" on Key side Forced interference during rotation with Zep Groove of Interlock Zep causes teeth to cut through anodization on module frame,resulting in robust and UL certified bonding path 1. \ Tongue Side Bonding - Tongue side in closed position --- Leveling Foot Module ----- Down-roof ZS Comp Cutaway Illustration Cutti Forced interference between mating parts from module rg"teeth" Bonding location on rock in motion cuts into module frame.removing Tongue side anodization and resulting in robust and UL certified bonding path Document 800-1478-001 Rev A www.zepsotar.com PAGE: 1 0f 5 Document 800-1478-001 Rev A www.zepsolar.com PAGE: 2 of 5 ®2013/EN Zep Solar,Inc.Zep Solar reserves the right to make specifications chnages without any prior notice.All rights reserved. ®2013/EN Zep Solar,Inc.Zep Solar reserves the right to make specifications chnages without any prior notice.All rights reserved. Date Last Exported:June 25,2013 4:45 PM Date Last Exported:June 25,2013 4:45 PM ZepSolar ZS COMP I GROUNDING AND BONDING ZepSolar ZS COMP I GROUNDING AND BONDING Interlock, continued Leveling Foot Tongue side Key side Spring clip Part No.850-1388 i UL Listed to UL 2703 1 Bonding Path - Key and Tongue Part No.850-1397 The Leveling Foot top portion(the Rockit)has a stainless steel The Interlock bonds modules on all4 sides to create a hyper- UL Listed to UL 2703 spring clip that bonds to the adjacent module frame on both YP Key and Tongue sides. bonded array where every module Is structurally and electrically bonded to the surrounding modules. Leveling Foot - Bonding With Module Frame Module p� Tongue side O Down roc( 2 O b —e Interlock -° Key side � y Key side inserts into Zap Groove(rock-in) Module in next row drops in on the Tongue side Bonding Path -Array Bonding Path - North and South Modules 1 ® o Interlock _ _ Bonding location on A w` � �; _ �i Keyside Bonding path ® Leveling Foot ! �� M Bonding path c ® ED -- 'A ® T I Bonding location on Module rotation during drop-in creates forced ® 1 1 Down-roof Tongue side interference between Zep Groove and spring clip, 1 Down-roof `a cutting into moduleframe,removing anodization and resulting in robust and UL certified bonding path Document 800-1478-001 Rev A www.repsolar.com Document 800-1478-001 Rev A www.zepsolar.com PAGE: 4 Of 5 02013/ENZep Solar.Inc.Ze Solar reserves theri httomakes specifications PAGE: 30f5 p g p g y prior notice.All rights reserved. 02013/EN Zap Solar,Inc.Zap Solar reserves the right to make specifications chnages without any prior notice.All rights reserved. Date Last Exported:June 25.20134:45 PM Date Last Exported:June 25.2013 4:45 PM Zep Solar ZS COMP I GROUNDING AND BONDING Ground Zep Set screw Key side The Ground Zep provides a single point of connection for the Equipment Grounding Conductor(EGC)from the array to a building ground. Ground wire channel Part No.850-1172 UL Listed to UL 467 and UL 2703 Ground Zep Installation O4 Insert Ground Zep into Zep Groove of module frame. Use the Flat Too to rotate the Ground Zep 90 degrees.so that set screw Insert copper EGC into ground wire on array perimeter is pointing straight up. channel.Tighten set screw using torque values shown in the ZS Comp Installa- tion Manual. Bonding Path -Array to Ground OGround Zep Equipment Ground Conductor Bonding path I I I I+ Down-roof Document 800-1478-001 Rev A www.zepsolar.com PAGE: 5 of 5 Z 2013JEN Zep Solar.Inc.Zep Solar reserves the right to make specifications chnages without any prior notice.All rights reserved. Date Last Exported:June 25.2013 4:45 PM SolarCity Standard Box 4J NOTICE OF COMPLETION U` AND AUTHORIZATION TO APPLY THE UL MARK The SolarCity Standard Box 4J is a • Manufactured to meet UL 1741 Standards. 12/21/2013 SolarCity Corp 4-String unfused Junction Box. The box . Non-Metallic, Corrosion Resistant NEMA 4X Enclosure. Alex Yang is highly configurable and adaptable 3055 Clearview Way using the (4)jumper blocks included in • Factory-Installed Cordgrip Enhances Installation Speed. San Mateo Ca 94402-3709,Us each box. A factory installed Cordgrip •Break-Thru Skinned-Over Glands on Cordgrip Provide enhances installer productivity. Weathertight Seal for All Configurations. Our Reference: E318537,Volume 1 Project Number 4786083586 •Easily Configurable Terminal Blocks Permit Adaptation Your Reference: A.Yang 10/7 Project Scope: Investigation of Photovoltaic(PV)System Combiner Box,model"SolarCity Standard Box 4C" to Site-Specific Stringing Needs. and Photovoltaic(PV)System Transition Box,model"SolarCity Standard Box 4X to UL 1741 Standard. Dear Alex Yang: Technical Data / Specifications Congratulations! UL's investigation of your product(s)has been completed under the above Reference Number and the product was determined to comply with the applicable requirements. This letter temporarily supplements the UL Follow-Up Services Procedure and serves as authorization to apply the UL Mark at authorized factories under UL's oVoltage Rating [VDC] .600V Follow-Up Service Program. To provide your manufacturer(s)with the intended authorization to use the UL Mark, you must send a copy of this notice to each manufacturing location currently authorized under E318537.Volume 1 ® Maximum DC Current [A]: 57A and including any special instructions as indicated in the addendum to this letter. ® O Maximum Continuous Current[Al:42A Records in the Follow-Up Services Procedure covering the product are now being prepared and will be sent in the ® Maximum Voltage[VDC]: 600V near future. Until then,this letter authorizes application of the UL Mark for 90 days from the date indicated above. Wire Size Range[AWG]: #6 to#14 Additional requirements related to your responsibilities as the Applicant can be found in the document"Applicant responsibilities related to Early Authorizations"that can be found at the following web-site: Enclosure Rating: NEMA 4X htto://www.ul.com/EAResponsibilities Operating Temperature Range ['Cl: 40 to 50 Any Information and documentation provided to you involving UL Mark services are provided on behalf of UL LLC yl1Y1 '; Typical Overall Dimensions[in]: 8"x6"x4" (UL)or any authorized licensee of UL. We are excited you are now able to apply the UL Mark to your products and appreciate your business. Feel free to contact me or any of our Customer Service representatives if you have any questions. 4 � ry4 6 Very truly yours, Reviewed by: Jon Adonay William R.Carney 408-754-6630 847/664-1088 Engineering Associate Lead Chief Engineer Director I 1 d 7 ``_ Jon.Adonay@ul.com William.R.Carney@ui.com NBKD9C5-90BA67 Awf,solarCity.o October2013 This is an electronically generated letter Signatures are not required for this document to be valid. Page 1 of 1