HomeMy WebLinkAboutCUP 2010-08 Riverside County Fire Department COAn 11 \ls'j(la.'RIVERSIDE COUNTY.'~~lI FIRE DEPARTMENT IN COOPERATION WITH THE NOV 2 9 2010 CALIFORNIA DEPARTMENT OF FORESTRY A D FIRE PROTECTION PROUDLY SERVING THE UNINCORPORATED AREAS OF RIVERSIDE COUNTYANDTHE CITIES OF: BANNING BEAUMONT CALIMESA CANYONI_AKE COACHELLA DESERT HO "r SPRINGS EASIVALE INDIAN WELLS INDIO LAKE ELSINORE LA QUINTA MENW EE MORENO VALLEY PALM DESERT PERRIS RANCHO MIRAGE_ RuBtDoux CSD SAN JACIN Io rEMECULA WILDOMAR BOARD OF SUPERVISORS: BOB BUSTER DISTRICT I JOHN TAVAGI_IONE DISTRICT 2 JEFIT STONE DISTRICT 3 JOHN BENOIT DISTRICT 4 2300 MARKET ST, STE 150, • RIVERSIDE, CA 92501 CONDITIONS OF APPROVAL CASE NUMBER: 10-LE-CUP-08 REVIEWED BY: AFM DANIEL WAGNER ON 10-28-2010 AUTOMOTIVE AND TOWING & STORAGE FACILITY, 29365 HUNCO WAY, LAKE ELSINORE APPLICANT. MATTHEW HARRIS, SR. PLANNER, 951 674-3124 X 279, Email: mharns lake-elsinore.com 10. GENERAL CONDITIONS 10.FIRE.999PC -#01 -West Fire Protection Planning Office Responsibility IN EFFECT It is the responsibility of the recipient of these Fire Department conditions to forward them to all interested parties. The permit number (as it is noted above) is required on all correspondence. Additional information is available at our website: www.rvcfire.org go to the link marked Ordinance 787". Questions should be directed to the Riverside County Fire Department, Fire Protection Planning Division at 2300 Market St. Suite 150, Riverside, Ca 92501. Phone: (951) 955- 4777, Fax: (951) 955-4886. 10.FIRE.999 CASE - CITY CASE STATEMENT IN EFFECT With respect to the conditions of approval for the referenced project, the Fire Department recommends the following fire protection measures be provided in accordance with Riverside County Ordinances and/or recognize fire protection standards MARION ASHLEY 11 77-933 Las Montaflas, Palm Desert, CA 92211 • (760) 863-8886 • Fax (760) 863-7072 DISTRICT5 CADocuments and SettingAawardWy Documents\Conditions\Conditions2\LAKE ELSINORE\2010 PLANNINGUO-LE-CUP-0811-18- 2010,doc Page 1 of 4 Page 30 of 36 10.FIRE.999 USE-#50-BLUE DOT REFELECTOR IN EFFECT Blue retro reflective pavement markers shall be mounted on private street, public streets and driveways to indicate location of fire hydrants. Prior to installation, placement of markers must be approved by Riverside County Fire Department. 10.FIRE.999 USE-#23- MIN REQ FIRE FLOW IN EFFECT Minimum required fire flow shall be 1500 GPM for 2 hours duration at 20 PSI residual operating pressure, which must be available before any combustible material is placed on the job site. Fire flow is based ©o type VB construction per the 2007 CBC and Ordinance 787; Building(s) having a fire sprinkler -system. 10.FIRE.999 USE-#20-SUPER FIRE HYDRANT IN EFFECT Super fire hydrant (s) (6" x 4" x 2 1/2') shall be located not less than 25 feet or more than 165 feet from any portion of the building as measured along approved vehicular travel ways. 10.FIRE.999 USE-#89-RAPID HAZMAT BOX IN EFFECT Rapid Entry Hazardous Material Data and Key Storage Cabinet shall be installed on outside of the building. Plans showing location of cabinet(s) shall be submitted to the Riverside County Fire Department for approval prior to installation (Current plan check deposit base fee is $126.00 10.FIRE.999 USE-PAINT BOOTH IN EFFECT Spray Paint Booth Plans must be submitted to the Fire Dept. for review and approval prior to installation. 10.FIRE.999 USE-#25- GATE ENTRANCES IN EFFECT Gate entrances shall be at least two feet wider than the width of the traffic lane (s) serving that gate. Any gate providing access from a road to a driveway shall be located at least 35 feet from the roadway and shall open to allow vehicle to stop with out obstructing traffic on the road. Where a one-way road with a single traffic lane provides access to a gate entrance, 40 foot turning radius shall be used. 77-933 Las Montanas, Palm Desert, CA 92211 • (760) 863-8886 • Fax (760) 863-7072 CADocutnents and Settings\award\My Documents\Conditions\Conditions2\LAKE ELSINORE\2010 PLANNING\10-LE-CUM8 11-18-2010.doc Page 2 of 4 Page 31 of 36 10.FIRE.999 USE-#88A-AUTOMATIC/MANUAL GATES IN EFFECT Gate (s) shall be automatic or manual operated, minimum 20 feet width, with a setback of 35 feet from face of curb/flow line. Gate access shall be equipped with a rapid entry system. Plans shall be submitted to the Fire Department for approval prior to installation. Automatic/manual gate pins shall be rated with shear pin force, not to exceed 30 foot pounds. Automatic gates shall be equipped with emergency backup power. Gates activated by the rapid entry system shall remain open until closed by the rapid entry system. Current plan check deposit base fee is $126.00. 80. PRIOR TO BUILDING PERMIT ISSUANCE 80.FIRE.999 USE-#17A-BLDG PLAN CHECK $IN EFFECT Building plan check deposit fee of $307 to $1,056.00, shall be paid in a check or money order to the Riverside County Fire Department after plans have been reviewed by our office. 80.FIRE.999 USE44 -WATER PLANS IN EFFECT The applicants or developer shall separately submit two copies of the water system plans to the Fire Department for review and approval. Calculated velocities shall not exceed 100 feet per second. Plans shall conform to the fire hydrant types, location and spacing. The system shall meet the fire flow requirements. Plans shall be signed and approved by a registered civil engineer and the local water company with the following certification: "I certify that the design of the water system is in accordance with the requirements prescribed by the Riverside County Fire Department." 90. PRIOR TO BUILDING FINAL INSPECTION 90.FIRE.999 USE-#45- FIRE LANES IN EFFECT The applicant shall prepare and submit to the Fire Department for approval, a site plan designating required fire lanes with appropriate lane painting and/or signs. 90.FIRE.999 USE-#12A- SPRINKLER SYSTEM IN EFFECT Install a complete fire sprinkler system per NFPA 13 2002 edition (13D and 13R system are not allowed) in all buildings requiring a fire flow of 1500 GPM or greater sprinkler system (s) with pipe size in excess of 4" inch diameter will require the project structural engineer to certify (wet signature) the stability of the building system for seismic and gravity loads to support the sprinkler system. All fire sprinkler risers shall be protected from any physical damage. The post indicator valve and fire department connection shall be located to the front, within 50 feet of a hydrant, and the minimum of 25 feet from the building (s). A statement that the building (s) will be automatically fire sprinkled must be included on the title page of the building plans. (Current sprinkler plan check deposit base fee is 614.00 per riser) applicant or developer shall be responsible to install a U.L. Central Station Monitored Fire Alarm System. Monitoring System shall monitor the fire Sprinkler system (s) water flow, P.I.V.'s and all control valves. Plans must be submitted to the Fire Department for approval prior to installation. Contact Fire Department for guideline handout (current monitoring plan check deposit base fee is $192.00) 77-933 Las Montanas, Palm Desert, CA 92211 • (760) 863-8886 • Fax (760) 863-7072 CADocuments and Settings\award\My Documents\Conditions\Conditions2\LAKE ELSINORE\2010 PLANNING\10-LE-CUP-08 11-18-2010.doc Page 3 of 4 Page 32 of 36 90.FIRE.999 USE-#27-EXTINGUISHERS IN EFFECT Install portable fire extinguishers with a minimum rating of 2A-10BC and signage. Fire Extinguishers located in public areas shall be in a recessed cabinets mounted 48" (Inches) to center above the floor level with Maximum 4" projection from the wall. Contact Fire Department for proper placement of equipment prior to installation. 90.FIRE.999 USE-#32-TITLE 19 IN EFFECT Comply with Title 19 of the California Administrative Code. 77-933 Las Montahas, Palm Desert, CA 92211 • (760) 863-8886 • Fax (760) 863-7072 CADocmnents and SettingAawardWy Documents\Conditions\ConditionS2\LAKP, ELSINORE\2010 PLANNING\10-LE-CUP-08 11-18-2010.dm Page 4 of 4 Page 33 of 36